You are on page 1of 45

UNCONTROLLED COPY: The master of this document is stored on an electronic

database and is "write protected"; it may be altered only by authorized persons. While
copies may be printed, it is not recommended. Viewing of the master electronically
ensures access to the current issue. Any hardcopies taken must be regarded as
uncontrolled copies.
ALCATEL-LUCENT CONFIDENTIAL: The information contained in this document is
the property of Alcatel-Lucent. Except as expressly authorized in writing by Alcatel-
Lucent, the holder shall keep all information contained herein confidential, shall
disclose the information only to its employees with a need to know, and shall protect
the information from disclosure and dissemination to third parties. Except as expressly
authorized in writing by Alcatel-Lucent, the holder is granted no rights to use the
information contained herein. If you have received this document in error, please notify
the sender and destroy it immediately.
2010 Alcatel-Lucent
All Rights Reserved

P
r
e
l
i
m
i
n
a
r
y
Alcatel-Lucent RRH60-21C Site
Specification
Installation Method 06-6143
December 20, 2010
Issue Number: 2.01
0 / Alcatel-Lucent RRH60-21C Site Specification
Method 06-6143 December 20, 2010

P
r
e
l
i
m
i
n
a
r
y
Alcatel-Lucent RRH60-21C Site Specification / 1
December 20, 2010 Method 06-6143
P
r
e
l
i
m
i
n
a
r
y
Table of Contents
1.0 General Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
1.1 Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
1.2 Sequence. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
1.3 Reason for Reissue . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
2.0 Material Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
2.1 Related Documents . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
2.2 Applicable Documents . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
3.0 General Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
3.1 Product Overview. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
3.1.1 Presentation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
3.1.2 Daisy Chain solution. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
3.1.3 Dimensions & Weight . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
3.1.4 Solar Shield . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
3.1.5 Bulkhead Overview. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
3.1.6 Environmental Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
3.2 Power Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
3.2.1 Preliminary . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
3.2.2 DC Power Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
3.2.3 Grounding. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
3.2.4 Main Characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
3.3 Site Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
3.3.1 Clearance of the Solution . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
3.3.2 Drilling. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
4.0 Site Preparation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
4.1 TMA Support (Optional) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
4.2 Ancillaries. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
4.2.1 Installation Principles . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
4.2.2 Wall Mounting Bracket . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
4.2.3 Floor Mounting Bracket . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
4.2.4 Pole Mounting Bracket . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
4.2.5 External Cable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
4.2.6 Optical Cable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
4.2.6.1 Optical Transceiver. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
4.2.6.2 Direct Connection. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36
4.2.7 RF Lightning Surge Protector . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36
4.3 Site Preparation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37
4.3.1 Customer DC connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37
4.3.2 Grounding and equipotential circuits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38
4.3.3 External Alarm Connection. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39
4.3.4 Feeders and Antennae System. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41
5.0 Appendices . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42
Appendix A Glossary. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42
Appendix B Ancillaries Characteristic . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43
Last Page. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44
2 / Alcatel-Lucent RRH60-21C Site Specification
Method 06-6143 December 20, 2010

P
r
e
l
i
m
i
n
a
r
y
Figures
Figure 1 RRH system overview in star or daisy chain configuration . . . . . . . . . . . . . . . . . . 6
Figure 2 Dimensions & weight of RRH without solar shield. . . . . . . . . . . . . . . . . . . . . . . . . 8
Figure 3 Dimensions & weight of RRH with DC solar shield . . . . . . . . . . . . . . . . . . . . . . . . 9
Figure 4 Solar shield (front cover) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Figure 5 RRH bulkhead overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Figure 6 RRH bulkhead overview- top view. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Figure 7 RRH bulkhead overview-side view . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Figure 8 RRH bulkhead overview-bottom view . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Figure 9 RRH bulkhead overview-GND. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Figure 10 Ground cable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Figure 11 Clearance of the RRH60-21C . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
Figure 12 Universal wall mounting kit drilling template . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
Figure 13 Universal floor mounting kit drilling template . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
Figure 14 TMA support from RRH60-21C . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
Figure 15 Unpack the RRH60-21C . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
Figure 16 Universal wall mounting bracket . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
Figure 17 Universal floor mounting bracket . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
Figure 18 Bracket to Pole Solution. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
Figure 19 External cable overview. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
Figure 20 Example of SFP optical transceiver: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
Figure 21 Optical cable type . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34
Figure 22 Optical cable for direct connection (LC/LC connectors). . . . . . . . . . . . . . . . . . . 35
Figure 23 Customer breaker schematic connection in single phase . . . . . . . . . . . . . . . . 36
Figure 24 Example of 48V breaker distribution . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36
Figure 25 Cable trays equipotentiality . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37
Figure 26 External alarm cable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38
Figure 27 Lightning protection on feeders (example). . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40
Figure 28 DC power cable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42
Figure 29 Optical fiber LC / LC. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42
Figure 30 Ground cable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42
Figure 31 External alarm cable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43
Alcatel-Lucent RRH60-21C Site Specification / 3
December 20, 2010 Method 06-6143
P
r
e
l
i
m
i
n
a
r
y
Tables
Table 1 Dimensions & weight of RRH60-21C. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Table 2 RRH60-21C environmental requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Table 3 Main characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
Table 4 Distance constraints. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
Table 5 TMA support. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
Table 6 External cables. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
Table 7 SFP code . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
Table 8 Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
Table 9 Optical cable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34
Table 10 Alarm pin out . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39
4 / Alcatel-Lucent RRH60-21C Site Specification
Method 06-6143 December 20, 2010

P
r
e
l
i
m
i
n
a
r
y
1.0 General Information
1.1 Description
Purpose: This document:
Describes the characteristics of the Remote Radio Head
solution for UMTS in the 2100MHz band. Its naming is Alcatel-
Lucent Remote Radio Head 60W 2100MHz C. (RRH60-21C)
Defines the specifications covering the selection and
preparation of the site that must receive the RRH60-21C.
Equipment: This document applies to the deployment of the
RRH60-21C.
Application: This document is used to define RRH60-21C site
requirement.
Service Impact: None
1.2 Sequence
Installation Methods can be found at:
https://wcdma-ll.app.alcatel-lucent.com/livelink/livelink.exe/fetch/
2000/29267553/29445737/36413001/36566963/36528788/
36528896/
customview%2Ehtml?func=ll&objId=36528896&objAction=brow
se&sort=name&viewType=1
This is a stand-alone method.
1.3 Reason for Reissue
Reason for update:
Issue 201 (20/12/10)
- Preliminary version for UA7.1
Alcatel-Lucent RRH60-21C Site Specification / 5
December 20, 2010 Method 06-6143
P
r
e
l
i
m
i
n
a
r
y
2.0 Material Requirements
2.1 Related Documents
The following documents are required to complete this method
Please refer to:
Description of the main characteristics of the product, can be
found at
https://wcdma-ll.app.alcatel-lucent.com/livelink/
livelink.exe?func=ll&objId=41590882&objAction=browse&sort=n
ame&viewType=1
Model Offer Provisioning Guide (MOPG) for all ordering codes,
can be found at:
https://wcdma-ll.app.alcatel-lucent.com/livelink/
livelink.exe?func=ll&objId=55620155&objAction=browse&sort=n
ame&viewType=1
2.2 Applicable Documents
Product (NodeB, RRH, etc...)Safety Installation Requirements
and instructions can be found at:
https://wcdma-ll.app.alcatel-lucent.com/livelink/
livelink.exe?func=ll&objId=31829265&objAction=browse&sort=n
ame&viewType=1
6 / Alcatel-Lucent RRH60-21C Site Specification
Method 06-6143 December 20, 2010

P
r
e
l
i
m
i
n
a
r
y
3.0 General Information
3.1 Product Overview
3.1.1 Presentation
Figure 1 RRH system overview in star or daisy chain configuration
Star Configuration
Daisy Chain Configuration
RRH60 RRH60 RRH60
optical fiber
CPRI CPRI
CPRI
Remote site
Centralized site
RRH60-21C
Optical interface
NodeB
in d2U V2 Node B
The RRH solution is based on digital NodeB (9326 d2U V2 for
example) and RRH60-21C.
The Distributed solution is composed of two optical interfaces
(refer to Figure 5):
The main interface located within the dNodeB.
The RRH, located on the remote site.
These two modules are linked by optical fibers, carrying UMTS
downlink and uplink base band digital signals, and OAM
information.
Alcatel-Lucent RRH60-21C Site Specification / 7
December 20, 2010 Method 06-6143
P
r
e
l
i
m
i
n
a
r
y
3.1.2 Daisy Chain solution
The daisy chain allows to connect RRHs on one single optical link
connected to the digital NodeB part.
Daisy chain RRH operates in sector mode, with a maximum of 6
cells per fiber link.
BTS is able to support 12 cells (carriers 2 sectors) => up to two
links in the above configurations.
For more details refer to the PEI document (Related Documents
on page 5).
3.1.3 Dimensions & Weight
The RRH60-21C is composed of:
The body.
The Solar Shield: Used for thermal protection. The shield cover
is assembled to RRH body on site.
8 / Alcatel-Lucent RRH60-21C Site Specification
Method 06-6143 December 20, 2010

P
r
e
l
i
m
i
n
a
r
y
Figure 2
465 mm
270 mm
150 mm
Without solar shield: 14.6 Kg (32.19 lbs)

Length: 465 mm (18.30 in)
Width: 270 mm (10.63 in)
Depth: 150 mm (5.91 in)

Dimensions
Without Solar Shield

Unit Weight

Dimensions & weight of RRH without solar shield
Alcatel-Lucent RRH60-21C Site Specification / 9
December 20, 2010 Method 06-6143
P
r
e
l
i
m
i
n
a
r
y
Figure 3 Dimensions & weight of RRH with DC solar shield
Solar Shield radiation, insulation
465 mm
270 mm
150 mm

Dimensions
With DC solar shield: 15.88 Kg (35.01 Ibs)
Length: 485 mm (19.10 in)
Width: 300 mm (11.81 in)
Depth: 193 mm (7.56 in)

With DC Solar Shield
Unit Weight
.
Table 1 Dimensions & weight of RRH60-21C
Parameter RRH w/o Solar
Shield
RRH with DC Solar
Shield
Length
465 mm (18.30 in) 485 mm (19.10 in)
Width
270 mm (10.63 in) 300 mm (11.81 in)
Depth
150 mm (5.91 in) 192 mm (7.56 in)
Weight
14,6 Kg (32.19 lbs) 15.88 Kg (35.01 Ibs)
10 / Alcatel-Lucent RRH60-21C Site Specification
Method 06-6143 December 20, 2010

P
r
e
l
i
m
i
n
a
r
y
3.1.4 Solar Shield
The shield cover: Used for thermal protection The shield cover is
assembled to RRH body on site.
Figure 4 Solar shield
Alcatel-Lucent RRH60-21C Site Specification / 11
December 20, 2010 Method 06-6143
P
r
e
l
i
m
i
n
a
r
y
3.1.5 Bulkhead Overview
Figure 5 RRH bulkhead overview
Data Master Data Slave
Figure 6 RRH bulkhead overview- top view
Tx/Rx Main
Rx Diversity
7/16 RF connection
12 / Alcatel-Lucent RRH60-21C Site Specification
Method 06-6143 December 20, 2010

P
r
e
l
i
m
i
n
a
r
y
Figure 7 RRH bulkhead overview-side view
Figure 8 RRH bulkhead overview-bottom view
AISG DC Power
Alcatel-Lucent RRH60-21C Site Specification / 13
December 20, 2010 Method 06-6143
P
r
e
l
i
m
i
n
a
r
y
Figure 9 RRH bulkhead overview-GND
GND
These figures give an overview of the different connectors
present on the bulkhead of the RRH
Below the RRH:
Power Input: Connector type, 3 pin female for the connection
of DC.
AISG: Circular connector female 8P for connection with an AISG
RETA equipment
Side of the RRH:
Data Slave: Optical main connection for the up stream
communication (dNodeB).
Data Master: Optical cascading connection for the downstream
communication (only used in a daisy configuration).
Type of connection: SFP cage + optical transceiver + optical LC
Ext Alarm connectors: 15-pin sub_D connector). The RRH is
able to report 4 external alarms to the OMC.
Top of the RRH:
ANT Tx/Rx: 7/16 DIN coaxial female connector for the
connection with the main antenna
ANT Rx: 7/16 DIN coaxial female connector for the connection
with the diversity antenna.
14 / Alcatel-Lucent RRH60-21C Site Specification
Method 06-6143 December 20, 2010

P
r
e
l
i
m
i
n
a
r
y
3.1.6 Environmental Requirements
The RRH60-21C is designed to be installed in outdoor
environment with the following requirements.
Table 2 RRH60-21C environmental requirements
Requirement Description
Manufacturing Manufactured according to the WEEE (Waste of Electrical
and Electronic Equipment) and RoHS (Restriction of
Hazardous Substances) recommendations.
Ingress protection Weather resistant to prevent ingress of rain, snow, dust and
other solid foreign objects to a minimum level of IP65.
The corrosion requirements is over the 15 years lifetime.
Climate Operates at full specification within the temperature range -
40 C to +55C, including solar radiation at 1120W/m.
Designed to operate under:
the absolute humidity range of 0.03 g/m3 to 36 g/m3
the relative humidity range 5% to 100%
Wind speed When fully installed, designed to withstand the over-turning
force exerted by a wind speed of 200km/h.
Wind load is 200N at 150km/h wind speed, when RRH is
equipped with solar shield cover.
Acoustic noise No noise generated because RRH is not equipped with fan
(natural convection cooling).
Altitude Up to 15,000 feet where the max ambient temperature
decreased by 0.5 degrees C per 1,000 feet above sea level.
Alcatel-Lucent RRH60-21C Site Specification / 15
December 20, 2010 Method 06-6143
P
r
e
l
i
m
i
n
a
r
y
3.2 Power Requirements
3.2.1 Preliminary
The RRH60-21C must be connected to a -48V DC power supply.
3.2.2 DC Power Mode
The power supply range is from -40VDC to -57VDC.
The maximum DC power consumption of RRH is 300W.
3.2.3 Grounding
A Ground cable can be connected directly to the RRH60-21C with
M6 screw and cable with lug(double lug).
Figure 10 Ground cable
16m
Single Lug
16 / Alcatel-Lucent RRH60-21C Site Specification
Method 06-6143 December 20, 2010

P
r
e
l
i
m
i
n
a
r
y
3.2.4 Main Characteristics
Main characteristics are summarized in the following table.
Table 3 Main characteristics
RF Characteristics
RRH60-21C BandI
Uplink frequency 1920 MHz ~ 1980 MHz
Downlink frequency 2110 MHz ~ 2170 MHz
Number of carriers 4 continuous carriers
RRH output power
@ antenna connector
60W typical RF power:
60W x 1 carrier
30W x 2 carriers
20W x 3 carriers
15W x 4 carriers
TX diversity supported
with 2 RRH per sector
3 RRHs co-located, using daisy-chain feature; also applicable to
STSR1+1 configuration With two RRH per sector. (In the future)
Nominal impedance 50 Ohms
Antenna port return loss 14 dB min
Optical & topology characteristics
Type/number of fibers CPRI rate 2 (1,228 Gb/s), CPRI rate 3 (2,457 Gb/s).
Single-mode (SM) Single-fiber (SF) variant: one SM fiber per
RRH carrying UL and DL signals using CWDM.
Single-mode (SM) Dual-fiber (DF) variant: one SM fibers per
RRH carrying UL and one carrying DL.
Multi-mode (MM) Dual-fiber (DF) variant: two MM fibers per
RRH, one carrying UL, 2nd carrying DL.
Optical fiber length
Up to 500 m, using MM fiber
Up to 20 km, using SM fiber (15 km in CPRI rate 3)
Number of RRH per
sector
1, up to 2 in TX diversity / STSR+Y
Operating
temperature
-40C to +55C (with solar load)
Storage/Transportation
temperature range
-40C to +70C
Alcatel-Lucent RRH60-21C Site Specification / 17
December 20, 2010 Method 06-6143
P
r
e
l
i
m
i
n
a
r
y
Typical power
consumption
260W @ 60W RF output power
Miscellaneous
Dimensions and weight Unit Dimensions:
Size without solar shield: 465x270x150mm = 18.8 liter
Size with DC solar shield: 485x300x193mm
Size with AC/DC solar shield: 485x300x260mm
Unit Weight:
without solar cove:14.6 Kg
with DC solar shield: 15.88 Kg
with AC/DC solar shield: 16.06 Kg
Power supply
DC power supply variant: -48V (-40V to -57V).
Number of external
alarms
4 protected external alarms, supported in OAM.
Table 3 Main characteristics
18 / Alcatel-Lucent RRH60-21C Site Specification
Method 06-6143 December 20, 2010

P
r
e
l
i
m
i
n
a
r
y
3.3 Site Requirements
3.3.1 Clearance of the Solution
Figure 11 Clearance of the RRH60-21C






3
0
0

m
m
350 mm
3
0
0

m
m
200 mm
Recommended
400mm(13.78in)
(7.87in)
(
1
1
.
8
1
i
n
)
(
1
1
.
8
1
i
n
)
(13.78in)
Table 4 Distance constraints
Recommended
distance
Comment
Side clearance 400 mm (13.78in) To secure RRH body on the mounting kit.
To change the shield cover and open the
service window.
Top clearance 300 mm(11.81in) For natural convection, if necessary
bending radius RF jumper
Bottom clearance 300 mm(11.81in) For cable connections (bending radius)
Front clearance 460 mm(18.11in) For the installation of the RRH
and the removal of the FRU
Rear clearance 70m m (2.76in) For the wall mounting kit
Alcatel-Lucent RRH60-21C Site Specification / 19
December 20, 2010 Method 06-6143
P
r
e
l
i
m
i
n
a
r
y
3.3.2 Drilling
The RRH60-21C is designed to be installed with a wall mounting
kit.
There is one kinds of mounting bracket can be used:
Universal mounting bracket
Note: One limition to universal kit that service door could not be
open after RRH isolated into kit.
20 / Alcatel-Lucent RRH60-21C Site Specification
Method 06-6143 December 20, 2010

P
r
e
l
i
m
i
n
a
r
y
Figure 12 Universal wall mounting kit drilling template
Alcatel-Lucent RRH60-21C Site Specification / 21
December 20, 2010 Method 06-6143
P
r
e
l
i
m
i
n
a
r
y
The RRH60-21C is also designed to be installed with a floor
mounting kit
There is one kinds of mounting bracket can be used:
Universal mounting bracket
Figure 13 Universal floor mounting kit drilling template
22 / Alcatel-Lucent RRH60-21C Site Specification
Method 06-6143 December 20, 2010

P
r
e
l
i
m
i
n
a
r
y
4.0 Site Preparation
4.1 TMA Support (Optional)
RRH60-21C can support TMA in two different modes.
Current alarm mode:
TMA is powered and monitored (thanks to power supply current
sensing) through RRH AISG port, using external bias-tees and a
specific cabling (TMA Y-cable) as shown Figure 14
AISG mode:
RRH60-21C can support TMA through AISG:
In the future, RRH60-21C will support RETA through AISG.
This will require to install an AISG bias-tee on one of the two
feeders, and one AISG cable between AISG bias-tee and RRH
AISG port.
Figure 14 TMA support from RRH60-21C
Bias Tees
RRH
X
X
X
X
X
TMA
AISG
port
TMA Y-cable)
Bias-T

Table 5 TMA support
Description Provisioning Rule
TMA 2100 AISG ROHS version 1 by RRH
Bias-T /BTS_DINm/ ANT_DINf 2 by RRH
ASSEMBLY, cable, 2100RRH, BIAS-
T,Y,AISG-SMA, BLK, 2M
1 by RRH
(TMA Y Cable)
Alcatel-Lucent RRH60-21C Site Specification / 23
December 20, 2010 Method 06-6143
P
r
e
l
i
m
i
n
a
r
y
24 / Alcatel-Lucent RRH60-21C Site Specification
Method 06-6143 December 20, 2010

P
r
e
l
i
m
i
n
a
r
y
4.2 Ancillaries
4.2.1 Installation Principles
The RRH can be installed on a wall, a floor or a pole. The
supporting wall, floor or pole must be vertical (maximum tilt of
5%).
The pole mounting kits are designed to support pipes with
diameter from 50 to 380mm.
The kits are designed to be mounted alone and then hang and
lock the RRH on it.
The RRH has been designed to be carried by only one person.
Figure 15 Unpack the RRH60-21C
Install mounting kit 1 Unpack RRH 2
Alcatel-Lucent RRH60-21C Site Specification / 25
December 20, 2010 Method 06-6143
P
r
e
l
i
m
i
n
a
r
y
4.2.2 Wall Mounting Bracket
The wall must be flat and vertical (maximum tilt of 5%).1 kit is
available, this kit to be used is wall mounting bracket/plate RRH.
The securing of this installation kit (Bolts, pegs) should be
supported by the customer, depending on the type of wall (hollow,
plaster, wood walls and concrete) each securing parts should be
correctly designed.
ex: Pegs (expansion bolt set) exclusively for a concrete full wall.
The securing system to the wall must satisfy the following
characteristics:
shearing: 120 daN (120 kg - 264.5 lb)
tearing: 120 daN (120 kg - 264.5 lb).
Figure 16 Universal wall mounting bracket
4.2.3 Floor Mounting Bracket
The floor must be flat (maximum fluctuation of 5%).1 kit is
available ,this kit to be used is floor mounting bracket/plate RRH.
The securing of this installation kit (Bolts, pegs) should be
supported by the customer, depending on the type of floor each
securing part should be correctly designed.
26 / Alcatel-Lucent RRH60-21C Site Specification
Method 06-6143 December 20, 2010

P
r
e
l
i
m
i
n
a
r
y
Figure 17 Universal floor mounting bracket
4.2.4 Pole Mounting Bracket
The mounting kit must be installed vertically. According to the
diameter of the pipe, 2 kits are available the kits to be used are:
for a pole diameter between 152 and 380mm:
Wall mounting bracket/Plate RRH and Kit, STD Pole mounting
bracket and Band.
for a pole diameter between 50 and 152mm:
Wall mounting bracket/Plate RRH and Bracket, PIPE Mounting.
Alcatel-Lucent RRH60-21C Site Specification / 27
December 20, 2010 Method 06-6143
P
r
e
l
i
m
i
n
a
r
y
Figure 18
Pole Mounting Bracket (50-152mm)
Pole Mounting Standard (152-380mm)
Wall Bracket
Pole Bands
Pole Brackets
Bracket to Pole Solution
28 / Alcatel-Lucent RRH60-21C Site Specification
Method 06-6143 December 20, 2010

P
r
e
l
i
m
i
n
a
r
y
4.2.5 External Cable
Figure 19 External cable overview
Customer power plant
External cables


Optical cables


RRH
Table 6 gives the designation of the external cables (without
optical cable) needed for the connection between the bulkhead of
the RRH and the customer power plant.
The length of optical fibers are available in 5m, 15m, 30m, 50m,
70m, 85m, 100m, 150m, 200m, 250m and 300m (SM-DF, SM-SF,
MM-DF).
The length of the DC cable provided is 15m.
Alcatel-Lucent RRH60-21C Site Specification / 29
December 20, 2010 Method 06-6143
P
r
e
l
i
m
i
n
a
r
y

Table 6 External cables
Designation Length Comment
DC input cable
needed for RRH:
15 m Cable type use 2 cores AWG10 (6 mm2)
For the specification of the cable refer to Appendix B ,
"Ancillaries Characteristic," on page 42.
Ground cable with a
simple lug
mandatory in all case.
16 m 1 flexible conductor: yellow-green = ground
16 mm2
Lug stud M6
For the specification of the cable refer to Appendix B ,
"Ancillaries Characteristic," on page 42.
External alarm cable
needed for RRH:
15 m Twisted pairs 2x0.25 (24 AWG) stranded copper
Each pair is shielded with an aluminum foil and a drain wire
inside
For the specification of the cable refer to Appendix B ,
"Ancillaries Characteristic," on page 42.
AISG cable This cable should be delivered with the RETA equipment.
30 / Alcatel-Lucent RRH60-21C Site Specification
Method 06-6143 December 20, 2010

P
r
e
l
i
m
i
n
a
r
y
4.2.6 Optical Cable
4.2.6.1 Optical Transceiver
Two types are available according to SFP types:
Figure 20 Example of SFP optical transceiver:
SFP (SM)
SFP (MM)
The optical mode (SM or MM) is given by the distance between
the NodeB and the RRH:
Multi Mode (MM) fiber: One fiber carries the downlink signal
and a second one the uplink signal. The MM fiber is used for
short distance (<= 500 m (1640.4 ft)).
Single Mode (SM) fiber: Only one single fiber carries both
downlink and uplink signal. The SM fiber must be used for
distance up to 10km.
Table 7 SFP code
Code Code Description
300976297 SFP OPTICAL TRANSCEIVER (MULTI MODE, DUAL FIBER)
300976313 SFP OPTICAL TRANSCEIVER (SINGLE MODE, SINGLE
FIBER) for stat configuration
300976305 SFP OPTICAL TRANSCEIVER (SINGLE MODE, SINGLE
FIBER) for daisy-chain configuration
301030433 SFP, S-16.1, SM, 15KM, DUPLEX LC, -40/85
Alcatel-Lucent RRH60-21C Site Specification / 31
December 20, 2010 Method 06-6143
P
r
e
l
i
m
i
n
a
r
y
32 / Alcatel-Lucent RRH60-21C Site Specification
Method 06-6143 December 20, 2010

P
r
e
l
i
m
i
n
a
r
y
Configuration:
Only one SFP per RRH in star configuration (slave port).
Two SFP per RRH in daisy chain configuration, except on the last
RRH of the chain.
The table below gives the codes of the SFP for each config vs the
optical mode.
Table 8 Configuration
Mode Configuration SFP ref on Slave Port SFP ref on Master port
Multi-mode Star 300976297 N/A
Daisy Chain 300976297 300976297
Single mode
single fiber
Star 300976313 N/A
Daisy Chain 300976313 300976305
Single mode
dual fiber
Star 301030433 N/A
Daisy Chain 301030433 301030433
Alcatel-Lucent RRH60-21C Site Specification / 33
December 20, 2010 Method 06-6143
P
r
e
l
i
m
i
n
a
r
y
Optical cable equipped with fiber optic LC / LC.
Cable:
multimode and singlemode
compact design with 2 1.25 mm ferrules
Singlemode 9/125: Single fiber is supported (DL 1550 nm
UL1310 nm) or dual fiber 1310 nm
Multimode 50/125 m, 850 nm:(OM2 minimum for CPRI rate
2(1,2Gb/s) and OM3 for CPRI rate 3.
Optical requirements:
34 / Alcatel-Lucent RRH60-21C Site Specification
Method 06-6143 December 20, 2010

P
r
e
l
i
m
i
n
a
r
y
Figure 21 Optical cable type
LC TO LC (SM)
LC TO LC (MM)

Table 9 Optical cable
Connectors Fiber
1
5

m
3
0

m
5
0

m
7
0

m
8
5

m
1
0
0

m
For
LC to LC
MM-DF X X X X digital NodeB to RRH
SM-SF
SM-DF
X X X X
Alcatel-Lucent RRH60-21C Site Specification / 35
December 20, 2010 Method 06-6143
P
r
e
l
i
m
i
n
a
r
y
4.2.6.2 Direct Connection
Figure 22 Optical cable for direct connection
Direct Connection
(LC to LC)
BDC Connector
Centralized Site
Remote Site
Short distance between
the two sites
LC

Daisy Chain
(LC/LC connectors)
As depicted in Figure 22, direct optical connection could be used
when the distance between the NodeB and the RRH sites is equal
or less than 300m.The maximum distance between NodeB and
first RRH is 10km in Single Mode and 500 in Multi Mode.
4.2.7 RF Lightning Surge Protector
RF lightning surge protection is integrated into the RRH
36 / Alcatel-Lucent RRH60-21C Site Specification
Method 06-6143 December 20, 2010

P
r
e
l
i
m
i
n
a
r
y
4.3 Site Preparation
4.3.1 Customer DC connection
The Customer DC connection should:
got an appropriate disconnection device according to the
connected equipment characteristics.
be easily accessible by the service team.
be marked as the disconnect device of the equipment.
One protected power supply branch is required for each
equipment installed on site.
We recommend a breaker a 2 pole 10A C-char. following Figure
23 .
Figure 23 Customer breaker schematic connection in single phase
10A
RRH1
RRH dedicated breaker,
unipolar, C curve
Main 48V
Single Phase
RRH2
RRH3
10A
10A
Figure 24 Example of 48V breaker distribution
The acceptable variations of the input voltage, under normal
operation, is from -40V to -57V.
Alcatel-Lucent RRH60-21C Site Specification / 37
December 20, 2010 Method 06-6143
P
r
e
l
i
m
i
n
a
r
y
It is recommended to connect the positive pole of the DC power
plant to the earth.
4.3.2 Grounding and equipotential circuits
Figure 25
Head of the screw
inside the cable tray
Washer
Washer
Nuts
Cable tray
Cable tray
lateral view
Equipotential braids
16mm (5AWG)
Equipotential braids
16mm (5AWG)
Equipotential
braids
Cable trays equipotentiality
If a cable tray is used for the external cables distribution, then the
cable tray should be correctly dimensioned and must be
grounded with 16 mm (5 AWG) braids to ensure the
equipotentiality (refer to Figure 25).
It is connected to the earth plate of the RRH site
The earth plate must be installed systematically on each RRH
site, all the site grounding circuits are connected to it:
RRHs grounding cable
Metallic conduits or cable trays
Antenna feeders grounding
Earth conductor of DC cable
The earth plate is continuously linked to the earth electrode of the
site.
The maximum impedance of the earth electrode measured from
38 / Alcatel-Lucent RRH60-21C Site Specification
Method 06-6143 December 20, 2010

P
r
e
l
i
m
i
n
a
r
y
the earth plate must be less than 10 Ohms.
4.3.3 External Alarm Connection
The RRH60-21C supports 4 externals alarms loops, Open =
Default.
The RRH60-21C is not connected directly to the supervised
equipments, but through the customer distribution box. This is a
connection point between the alarm cable from the RRH, and the
supervised equipment.
If a specific Alarm distribution frame is considered, then it should
be grounded.
Figure 26 External alarm cable
For characteristic refer to the Figure 29 "Optical fiber LC / LC"
on page 42
Sub_D Connector: 12 pin male Connector Electrical,
C09131H0122002, Cable, 12 Cont, Pin, Crimp, Male,
Cable: 4 pairs, 2x0.25 (24AWG) Cable Electronic, N510910002z,
3 Pr, 24 Ga, Non-connectorized, 300 V
Table 10 Alarm pin out
Contact Signal Wire color for example
A EXT_IN0_A black
B EXT_IN0_B brown
C EXT_IN1_C white
D EXT_IN2_D orange
E EXT_IN2_E yellow
F EXT_IN3_F light green
G EXT_IN3_G light blue
H NC
J NC
K NC
L EXT_IN1_L pink
M NC
Alcatel-Lucent RRH60-21C Site Specification / 39
December 20, 2010 Method 06-6143
P
r
e
l
i
m
i
n
a
r
y
Note: The Pin out related to the wire color must be delivered with
the alarm cable.
40 / Alcatel-Lucent RRH60-21C Site Specification
Method 06-6143 December 20, 2010

P
r
e
l
i
m
i
n
a
r
y
4.3.4 Feeders and Antennae System
The customer must foresee and install the antennae system and
the feeders. The antennae are installed in compliance with the
radio engineering studies by trained staff.
Jumpers are mandatory between the RRH and feeders in order:
To allow an easier installation: depends on the size of feeder
used, it might be very difficult to position correctly the feeder in
top of the RRHs RF connector.
To avoid excessive efforts on the RRHs RF connector: risk to
damage the connectors.
To allow easier maintenance operation.
For antennas lightening protection it is recommended that the
radio lines from the antennas to the RRH are grounded with
dedicated grounding kits. (as an example refer to Figure 27).
Figure 27 Lightning protection on feeders (example)

Alcatel-Lucent RRH60-21C Site Specification / 41
December 20, 2010 Method 06-6143
P
r
e
l
i
m
i
n
a
r
y
5.0 Appendices
Appendix A Glossary
AISG Antenna Interface Standard Group
DDF Digital Distribution Frame
DC Direct Current
ODF Optical Distribution Frame
RET Remote Electrical Tilt
RETA Remote Electrical Tilt Automatic
RRH Remote Radio Head
RF Radio Frequency
RoHS Restriction of Hazardous Substance
TMA Tower Masthead Amplifier
42 / Alcatel-Lucent RRH60-21C Site Specification
Method 06-6143 December 20, 2010

P
r
e
l
i
m
i
n
a
r
y
Appendix B Ancillaries Characteristic
Figure 28 DC power cable
Figure 29
95.0 (+ / - 5.0)
( 3.74 ( + / - 0.2) )
95.0 (+ / - 5.0)
( 3.74 ( + / - 0.2) )
15m, 50m, 70m or 100m
Optical fiber LC / LC
Figure 30
Simple Lug
M6 Lug
16m
Ground cable
Alcatel-Lucent RRH60-21C Site Specification / 43
December 20, 2010 Method 06-6143
P
r
e
l
i
m
i
n
a
r
y
Figure 31 External alarm cable
Last Page