You are on page 1of 11

SMME NUST

Phone: 03475376846




Analyzed with SolidWorks Simulation Simulation of Upright_Model A 1


Simulation of
Upright_Model A

Date: Thursday, June 12, 2014
Designer: Awais Mumtaz
Study name: SimulationXpress Study
Analysis type: Static
Table of Contents
Description ............................................ 1
Assumptions .......................................... 2
Model Information ................................... 2
Material Properties .................................. 3
Loads and Fixtures................................... 4
Mesh Information .................................... 6
Study Results ......................................... 8
Conclusion .......................................... 11


Description
No Data


SMME NUST

Awais Mumtaz
6/12/2014



Analyzed with SolidWorks Simulation Simulation of Upright_Model A 2

Assumptions


Model Information


Model name: Upright_Model A
Current Configuration: Default
Solid Bodies
Document Name and
Reference
Treated As Volumetric Properties
Document Path/Date
Modified
Fillet52

Solid Body
Mass:1.36479 kg
Volume:0.000174973 m^3
Density:7800 kg/m^3
Weight:13.3749 N

C:\Users\Admin\Desktop\F
inal
Project\Upright_Model
A.SLDPRT
Jun 05 17:53:25 2014



SMME NUST

Awais Mumtaz
6/12/2014



Analyzed with SolidWorks Simulation Simulation of Upright_Model A 3

Material Properties
Model Reference Properties Components

Name: Plain Carbon Steel
Model type: Linear Elastic Isotropic
Default failure
criterion:
Max von Mises Stress
Yield strength: 2.20594e+008 N/m^2
Tensile strength: 3.99826e+008 N/m^2
SolidBody
1(Fillet52)(Upright_Model A)



SMME NUST

Awais Mumtaz
6/12/2014



Analyzed with SolidWorks Simulation Simulation of Upright_Model A 4

Loads and Fixtures
Fixture name Fixture Image Fixture Details
Fixed-2

Entities: 1 face(s)
Type: Fixed Geometry

Load name Load Image Load Details
Force-9

Entities: 1 face(s)
Type: Apply normal force
Value: 500 N
Force-10

Entities: 1 face(s)
Type: Apply normal force
Value: 1000 N
Force-11

Entities: 2 face(s)
Type: Apply normal force
Value: 250 N

SMME NUST

Awais Mumtaz
6/12/2014



Analyzed with SolidWorks Simulation Simulation of Upright_Model A 5

Force-12

Entities: 2 face(s)
Type: Apply normal force
Value: 250 N
Force-13

Entities: 2 face(s)
Type: Apply normal force
Value: 500 N
Force-14

Entities: 2 face(s)
Type: Apply normal force
Value: 500 N



SMME NUST

Awais Mumtaz
6/12/2014



Analyzed with SolidWorks Simulation Simulation of Upright_Model A 6

Mesh Information
Mesh type Solid Mesh
Mesher Used: Standard mesh
Automatic Transition: Off
Include Mesh Auto Loops: Off
Jacobian points 4 Points
Element Size 6.18903 mm
Tolerance 0.309451 mm
Mesh Quality High

Mesh Information - Details
Total Nodes 13685
Total Elements 7507
Maximum Aspect Ratio 16.63
% of elements with Aspect Ratio < 3 94.6
% of elements with Aspect Ratio > 10 0.04
% of distorted elements(Jacobian) 0
Time to complete mesh(hh;mm;ss): 00:00:04
Computer name: ASUSPC

SMME NUST

Awais Mumtaz
6/12/2014



Analyzed with SolidWorks Simulation Simulation of Upright_Model A 7




SMME NUST

Awais Mumtaz
6/12/2014



Analyzed with SolidWorks Simulation Simulation of Upright_Model A 8

Study Results

Name Type Min Max
Stress VON: von Mises Stress 20001.5 N/m^2
Node: 4994
3.66432e+007 N/m^2
Node: 1541

Upright_Model A-SimulationXpress Study-Stress-Stress

Name Type Min Max
Displacement URES: Resultant Displacement 0 mm
Node: 138
0.00626031 mm
Node: 10129

SMME NUST

Awais Mumtaz
6/12/2014



Analyzed with SolidWorks Simulation Simulation of Upright_Model A 9


Upright_Model A-SimulationXpress Study-Displacement-Displacement

Name Type
Deformation Deformed Shape

SMME NUST

Awais Mumtaz
6/12/2014



Analyzed with SolidWorks Simulation Simulation of Upright_Model A 10


Upright_Model A-SimulationXpress Study-Displacement-Deformation

Name Type Min Max
Factor of Safety Max von Mises Stress 6.02005
Node: 1541
11028.9
Node: 4994

SMME NUST

Awais Mumtaz
6/12/2014



Analyzed with SolidWorks Simulation Simulation of Upright_Model A 11


Upright_Model A-SimulationXpress Study-Factor of Safety-Factor of Safety



Conclusion

You might also like