You are on page 1of 4

Unit data sheets

Equipment Controller TSS-100 (EC100)

....................................................................................................................................................................................................................................

Processor daughter board

The processor daughter board provides the following hardware components required by
the FLC function:

Microprocessor
System memory, including boot flash EPROM and RAM
I/O parallel bus, including PCI and PCMCIA interface

Serial communication channels


General purpose parallel I/O
Real-Time Clock (RTC)

Equipment Controller TSS-100C (EC100C)


Part Number/
Mnemonic

Name

CLEI

ECI/Barcode

CPR

Status

8DG26031ABXX

Equipment
Controller

NGC5ALJFAA

171337

070VHK

Active

EC100C

Important! The 8DG26031ABXX EC100C must be installed in your shelf in order to


install Release 4.0. The 8DG26031ABXX EC100C replaces 8DG2822AAXX
EC100C.
The 8DG26031AAXX EC100 is not supported in Release 4.0 and later.
Features and application notes

Provides the First-Level Controller (FLC) function for the Alcatel-Lucent


1850 TSS-100C shelf

Provides the Operation, Administration and Maintenance (OAM) functions


Provides the Control and General Interface (CGI) function
Provides a mass-storage function, using a 1 GB flash disk (2.5 inch form factor,
44-pin IDE interface)

Two Equipment Controller TSS-100C (EC100C) cards equipped in a shelf provide


redundancy (1:1, non-revertive).

....................................................................................................................................................................................................................................
Alcatel-Lucent 1850 TSS-100/TSS-100C
C-21
8DG26342AAAATQZZA Release 4.1 (ETSI)
Issue 1 December 2011

Unit data sheets

Equipment Controller TSS-100C (EC100C)

....................................................................................................................................................................................................................................

Description

The EC100C is the FLC for the Alcatel-Lucent 1850 TSS-100C shelf. As an FLC, it
controls shelf management and communication. For the Control and General Interface
function, it manages physical interfaces for alarm collection and signaling. It also uses a 1
GB flash disk to provide mass storage functions.
The EC100C is a solid-state, etched-circuit module that plugs into a card cage. See Figure
C-9, Equipment Controller TSS-100C (EC100C) (p. C-22) for an outline of the
EC100C.
At least one EC100C is required for shelf operation. Two EC100Cs are required for
redundant operation.
Figure C-9 Equipment Controller TSS-100C (EC100C)
1
2
EPS

11

12
DOG

13

CM

14
AT AB

3
4
5
6
7
8
9
10

15

16
17
18

850-0021-1
060906

....................................................................................................................................................................................................................................
Alcatel-Lucent 1850 TSS-100/TSS-100C
C-22
8DG26342AAAATQZZA Release 4.1 (ETSI)
Issue 1 December 2011

Unit data sheets

Equipment Controller TSS-100C (EC100C)

....................................................................................................................................................................................................................................

Indicators and connectors

The EC100C has the following indicators and connectors (see Figure C-9, Equipment
Controller TSS-100C (EC100C) (p. C-22)):
Connector/Indicator

Description

Board Status Multicolor LED:

LED offCard not equipped or card equipped and not


provisioned

Green blinkSoftware boot/self test

GreenCard properly equipped and provisioned and in


service

RedCard failure

EPS Multicolor LED:

GreenEPS configured; card active

AmberEPS configured; card standby

OffEPS not configured

RJ-45 Ethernet status

GreenInterface active, blinks when exchanging packets

OffInterface inactive

LED always offNot used

Red LEDCritical alarm

Red LEDMajor alarm

Amber LED - Minor alarm

LED always offNot used

Red LEDAttended alarm

10

Orange LEDAbnormal condition

11

Reset command key

12

10/100 Ethernet debug RJ-45 connector (factory use only)

13

RS-232 on mUSB debug connector (F interface)

14

Local craft terminal mUSB connector (F interface)

15

Local craft terminal connector (RS-232 F interface)

16

USB interface for external memory device

17

Alarm cut-off key

18

Lamp test key

....................................................................................................................................................................................................................................
Alcatel-Lucent 1850 TSS-100/TSS-100C
C-23
8DG26342AAAATQZZA Release 4.1 (ETSI)
Issue 1 December 2011

Unit data sheets

Equipment Controller TSS-100C (EC100C)

....................................................................................................................................................................................................................................

Functional operation

The EC100C is composed of two boards, a main board and a processor daughter board,
and a mass memory device which is used to store all of the software packages and the
database for the Network Element (NE).
Main board

The main board provides circuits for the following functions:

Physical layer interface for the different system-related serial communication


channels supported by the FLC function
Station alarm signaling interfaces for rack lamps, remote alarms, and housekeeping
Mass storage interface connector
Module and system identification function

Module power supply


Remote Inventory (RI) function

Processor daughter board

The processor daughter board provides the following hardware components required by
the FLC function:

Microprocessor
System memory, including boot flash EPROM and RAM
I/O parallel bus, including PCI and PCMCIA interface
Serial communication channels

General purpose parallel I/O


Real-Time Clock (RTC)

Equipment Controller High Capacity (EC100A)


Part Number/
Mnemonic

Name

CLEI

ECI/Barcode

CPR

Status

8DG0822ABXX

Equipment
Controller High
Capacity

TBD

TBD

TBD

Active

EC100A

The EC100A is supported in Release 3.1 and later releases only.

....................................................................................................................................................................................................................................
Alcatel-Lucent 1850 TSS-100/TSS-100C
C-24
8DG26342AAAATQZZA Release 4.1 (ETSI)
Issue 1 December 2011