INSULATION - BILL OF QUANTITIES
1 ERECTION BILL OF QUANTITIES A
INSULATION - DOCUMENT and DRAWINGS
2 W01 EB 080 A 216.7
A 216.7
3 A
610 m2
8366 m2
200 m2
1400 m2
Remarks:
The Erection Standard Specification /EG.../EJ.../GS... will be provide later
Oman SUR
POWER ISLAND AND REST OF PLANT
PARTICULAR TECHNICAL SPECIFICATIONS - DRAWINGS & BILLS OF QUANTITY
TOTAL WEIGHT Plant Insulation ( Tonnes ) :
Piping Insulation area : 20268 m2
Equipment Insulation area : 820 m2
ABCD ERECTION TECHNICAL DOCUMENT
Power Turbo Systems
SUMMARY
INSULATION & HEAT TRACING of PI and ROP
Drum & BDT Insulation
Piping Insulation
Large Bore Valves to be insulated
Duct &/or Stack Insulation
INSULATION (PI & ROP)
INSULATION HRSG (BOILER), 2 Units
232992509.xls.ms_office
1/3
6/8/2014
ABCD LIST OF EQUIPMENT TO BE ERECTED (Power Island and Rest of Plant)
Plant Turbo System Date : 15-Dec-10
Rev: A
PROJECT : 2 x KA26-2 MS DC 1500 MW Oman Author: L. del Valle
Total for 1 Unit Total for 2 Unit
DESIGNATION COMMENTS DIMENSIONS Surface Total Surface Total
EB ES m2 Weight(T) m2 Weight(T)
EB80 THERMAL INSULATION Erection procedure EB 090 and EG 017 10544 m2 108.4 21088 m2 216.7
SURFACE DEFINITION
The surfaces mentionned hereafter are the EXTERNAL SURFACES OF HEAT INSULATION
The surface of a line is calculated with the equivalent length (Leq) (refer to EJ080/081 for details)
K25 SUMMARY OF SURFACE (EXTERNAL SURFACE OF INSULATION) PIPE DIAMETER
HEAT INSULATION FOR PIPING AND VALVES
HP piping and valves Average thickness of insulation = 160 mm All diameter 2125 m2 4250 m2
MP/LP piping and valves Average thickness of insulation = 50 mm Dia =< 2'' 2409 m2 4818 m2
MP/LP piping and valves Average thickness of insulation = 70 mm 2'' < Dia =< 6'' 2450 m2 4900 m2
MP/LP piping and valves Average thickness of insulation = 80 mm 6'' < Dia =< 16'' 1900 m2 3800 m2
MP/LP piping and valves Average thickness of insulation = 80 mm Dia > 16" 1250 m2 2500 m2
HEAT INSULATION FOR EQUIPMENT
Feed water tank and tanks Average thickness of insulation = 120 mm 300 m2 600 m2
Other equipment Average thickness of insulation = 80 mm 110 m2 220 m2
THERMAL INSULATION
SUR
232992509.xls.ms_office 6/8/2014
Alstom Power Inc.
Contract Name: Mittelsbueren
Contract No.: 31010001
Rev No.: 00
Date: 01/25/2010
Item Description
Qty per 1 nos.
HRSG
Degree of
Pre-assembly
Qty per 1
nos. HRSG
Drawing
Reference
Remarks
Length
[m]
Width
[m]
Height
[m]
Diam.
[m]
Surface
[m2]
INSULATION 5288 m2
Drum & BDT Insulation 1 LOT Loose parts 305 m2 NA
Piping Insulation 1 LOT Loose parts 4183 m2 NA
Large Bore Valves to be insulated 1 LOT Loose parts 100 pcs NA
Duct &/or Stack Insulation 1 LOT Loose parts 700 m2 NA
HRSG TY SCOPE MATERIAL SUMMARY