WATER- SOURCE HEAT PUMP SYSTEMS

7300 SW 44TH STREET


OKLAHOMA CI TY, OK 73179
( 800) - 299- 9747 FAX ( 405) - 745- 6058
CLI MATEMASTER. COM REV. : 1 MARCH, 2010
2
3 CommerCial HVaC
The changing face of commercial heating
and cooling requirements and solutions.
6 THe Two waTer-SourCe
SoluTionS
What is water-source and geothermal
heating and cooling?
11 THe ClimaTemaSTer
adVanTage
What makes ClimateMaster the global
leader in water-source heat pumps?
16 THe ClimaTemaSTer family
of produCTS (foldouT)
The largest and most diverse family of
water-source products of any manufacturer,
anywhere on the planet.
20 TranquiliTy 27

Two-STage
(TT) SerieS
Two to Six Ton
Two-Stage EarthPure

(HFC-410A)
Horizontal, Vertical, and Downflow Units.
Unit Features and Benefits, Dimensions,
Physical Data, and AHRI/ISO 13256-1
Performance Data.
22 TranquiliTy 20 Single-STage
(TS) SerieS
One-Half to Six Ton
Single-Stage EarthPure

(HFC-410A)
Horizontal, Vertical, and Downflow Units.
Unit Features and Benefits, Dimensions,
Physical Data, and AHRI/ISO 13256-1
Performance Data.
24 TranquiliTy HigH effiCienCy
(Tr) SerieS
One-Half to Five Ton
EarthPure

(HFC-410A)
Horizontal and Vertical Units.
Unit Features and Benefits, Dimensions,
Physical Data, and AHRI/ISO 13256-1
Performance Data.
26 TranquiliTy 16 CompaCT
(TC) SerieS
One-Half to Five Ton
EarthPure

(HFC-410A) Compact Units


Horizontal and Vertical Units.
Unit Features and Benefits, Dimensions,
Physical Data, and AHRI/ISO 13256-1
Performance Data.
28 TranquiliTy VerTiCal STaCk
(Trm) SerieS
Three-Quarter to Three Ton
EarthPure

(HFC-410A) Vertical Hi-Rise


Stack Units.
Unit Features and Benefits, Dimensions,
Physical Data, and AHRI/ISO 13256-1
Performance Data.
30 TranquiliTy ConSole (TrC)
SerieS
Three-Quarter to One and One-Half Ton
EarthPure

(HFC-410A) Console Units.


Unit Features and Benefits, Dimensions,
Physical Data, and AHRI/ISO 13256-1
Performance Data.
32 TranquiliTy CompaCT (TCH)
SerieS
Six to Ten Ton
EarthPure

(HFC-410A) Horizontal Units.


Unit Features and Benefits, Dimensions,
Physical Data, and AHRI/ISO 13256-1
Performance Data.
34 TranquiliTy large (Tl)
SerieS
Seven to Twenty-Five Ton
EarthPure

(HFC-410A) Vertical Units.


Unit Features and Benefits, Dimensions,
Physical Data, and AHRI/ISO 13256-1
Performance Data.
36 TranquiliTy waTer-To-waTer
(Tmw) SerieS
Three to Twenty-Eight Ton
EarthPure

(HFC-410A) Water-to-Water Units.


Unit Features and Benefits, Dimensions,
Physical Data, and AHRI/ISO 13256-2
Performance Data.
38 roofTop (Tre) SerieS
Three to Twenty Ton
EarthPure

(HFC-410A) Rooftop Units.


Unit Features and Benefits, Dimensions,
Physical Data, and AHRI/ISO 13256-1
Performance Data.
40 rx (erV) module
Rooftop Energy Recovery Units.
Unit Features and Benefits, Dimensions,
Physical Data, and AHRI-1060 Performance.
42 dediCaTed ouTdoor air (To)
SerieS
Three to One Hundred Ton
EarthPure

(HFC-410A) Horizontal and


Vertical Units.
Unit Features and Benefits, Dimensions.
Table of ConTenTS
4
The ever-changing environment of commercial
construction offers exciting breakthroughs in
technology and materials, but it is not without
some heartburn. Today, owners, architects, and
contractors face many challenges in the design and
construction of their projects. Challenges such as
usable space, indoor air quality, energy efciency,
maintenance costs, building longevity, and the
LEED

program all come to the forefront of the


design process. When considering the solutions to
these challenges, the type of HVAC system chosen
directly affects each one.
uSable SpaCe
It has been said that the reason real estate grows
in value is because no one is making any more. As
cities continue to grow and spread out, the value
of maximizing usable space becomes increasingly
important. When selecting an HVAC system, you
positively or negatively impact the usable space
on a project. As an example,
VAV (Variable Air Volume)
systems utilize complicated
ductwork systems along
with extensive equipment
rooms to deliver conditioned
air into the building space.
Additionally, VAV duct
systems many times require
more ceiling height which increases oor-to-
oor space thus increasing building costs. By
comparison, ClimateMaster Water-Source and
Geothermal Heat Pump systems require little to
no equipment room space and use a very simple,
compact, and independent ductwork system.
indoor air qualiTy
As important as the actual temperature of a
building space is, the quality of air within that
space is equally important. The American Society
of Heating, Refrigerating, and Air Conditioning
Engineers (ASHRAE) has implemented Standard
62, which requires signicantly higher amounts of
fresh outdoor air for buildings. The challenge now
becomes how to properly introduce, condition,
and deliver this fresh air into the building space.
Traditional options like two- and four-pipe Fan Coil
systems must be up-sized signicantly to handle the
additional conditioning load. This means larger,
more expensive units, larger, more expensive
piping, and larger, more expensive boilers and
chillers. In comparison, ClimateMaster systems
offer a variety of options that can actually lower
the overall system size, introduce 100% outdoor
air, and lower system usage cost.
energy effiCienCy
Todays ofces equipped with computers, copiers
and other ofce tools can dramatically affect
the heating and cooling load of a given space.
When considering heating and cooling loads,
rising energy costs demand an HVAC system
that is efcient while building designs require a
system that is also exible. ClimateMaster has a
solution for practically any application, and does
so with some of the most energy efcient HVAC
systems available on the market today. In fact, all
of ClimateMasters products either meet or exceed
the new federal mandated efciency minimums.
mainTenanCe CoSTS
Complex systems such as two- and four-pipe
fan coils and VAV systems require advanced
maintenance and the trained personnel to
perform it. Large equipment rooms lled with
chillers, air handlers, or large-scale boilers require
personnel for monitoring and maintenance,
which consume building space and leasing
prots. The effect to the bottom line becomes
signicant when considering the potential of a
complete system failure along with costly parts and
equipment replacement. However, water-source
and geothermal heat pumps require very little
monitoring and maintenance - aside from routine
lter changes. With factory installed DDC controls,
the entire building can be accessed via any web-
enabled computer for monitoring and set point
control. No muss, no fuss, no worries.
building longeViTy
New innovations offer longer life expectancies
for todays buildings. You should expect the same
from the HVAC systems
being placed inside these
buildings. However, when it
comes to longevity, not all
systems are created equal.
Complex chillers and air
handling systems often have
a large number of moving
parts that will wear out
over time. Water-source
and geothermal heat pumps offer the advantage
of very few moving parts. Fewer moving parts
lower the occurrence of parts replacement and
extend equipment life. This simplicity of design
allows ClimateMaster systems to provide average
life spans of 20 years or more. In fact, there are
a number of ClimateMaster units that are still
performing after 50 years - providing the continual
comfort our customers have come to expect.
CommerCial HVaC
5
many CHoiCeS, one SoluTion
When choosing a HVAC system for a project, there
are four basic types from which to choose.
fan CoilS
Fan coil systems are comprised of water-to-air coil air
handlers connected via a two- or four-pipe insulated
water loop. Fan coils require complex chillers and
boilers to provide water loop uid in a particular
temperature range (i.e. chilled water for cooling
and hot water for heating). Two-pipe fan coils have
a major disadvantage as control is substantially
limited to whatever mode the system is currently set
at (i.e. cooling or heating). A four-pipe version can
be installed that requires both chilled and heated
water to be available at the same time. Four-pipe
systems also require twice the piping and twice the
circulation equipment of a two-pipe system, which
makes a four-pipe system one of the
most expensive systems to install.
Variable air
Volume (VaV)
Variable Air Volume, or VAV, is one
of the most common types of HVAC
systems used in large commercial
buildings today. A typical system
is usually comprised of a large air
handler, central ductwork system,
and a relatively large equipment
room. Conditioned air is distributed
throughout the building via a central
ductwork system and is regulated via
dampers in each space. VAV systems
typically have a higher rst cost than
water-source heat pumps, and may
have similar operating costs, resulting
in overall increased life cycle costs.
roofTop
Rooftop systems are similar to VAV systems in that
they use a central ductwork system to distribute
conditioned air into the building space. However,
instead of one central unit, the system is comprised
of multiple units which can be tasked for different
conditioning requirements. Rooftop systems usually
require additional structural reenforcement as well
as cranes or other lifting equipment to place the
units. Control in a particular zone is limited to what
the system is currently set to (i.e. cooling or heating).
Rooftop installation costs are low to moderate, but
operating costs are typically 50% higher than water-
source heat pumps. Additionally, the systems are
exposed to the elements and are subject to damage
and vandalism.
waTer-SourCe and
geoTHermal HeaT pumpS
Water-source and geothermal heat pump systems
are comprised of individual packaged units
that transfer heat via a single- or two-pipe water
loop. Each unit can be used in either heating or
cooling mode year-round and loop temperature is
maintained via a boiler/tower combination or earth-
coupled loop. Each zone has complete control of its
heating/cooling mode and each unit is independent
from the others. This means if one unit goes down,
the whole system is not affected. Controls can be as
simple as one unit, one thermostat. Water-source and
geothermal heat pump systems are the most energy,
cost, and space efcient of any system in
the industry.
SySTem CompariSon
System
E
a
s
e

o
f

D
e
s
i
g
n
E
a
s
e

o
f

I
n
s
t
a
l
l
a
t
i
o
n
I
n
s
t
a
l
l
a
t
i
o
n

S
p
a
c
e
I
n
s
t
a
l
l
a
t
i
o
n

C
o
s
t
M
a
i
n
t
e
n
a
n
c
e

R
e
q
u
i
r
e
m
e
n
t
s
M
a
i
n
t
e
n
a
n
c
e

C
o
s
t
s
F
u
t
u
r
e

S
y
s
t
e
m

E
x
p
a
n
s
i
o
n
S
o
u
n
d

L
e
v
e
l
s
O
p
e
r
a
t
i
n
g

C
o
s
t
s
T
o
t
a
l

Z
o
n
e

F
a
i
l
u
r
e

C
h
a
n
c
e
I
n
d
i
v
i
d
u
a
l

T
e
n
a
n
t

C
o
n
t
r
o
l
O
p
t
i
o
n
s
A
d
d
i
t
i
o
n
a
l

A
u
x
i
l
i
a
r
y

E
q
u
i
p
m
e
n
t

N
e
e
d
e
d
S
t
r
u
c
t
u
r
e


M
o
d
i

c
a
t
i
o
n

N
e
e
d
s

S
y
s
t
e
m

L
o
n
g
e
v
i
t
y
Two-Pipe Fan Coils Low Low High Med High High Low Low Med High Low Low High High Med
Four-Pipe Fan Coils Low Low High High High High Low Low High High Low Low High High Med
PTAC / PTHP Low Low Low Low High High Med High High Low Med Low Med High Low
VAV Low Low High Med High High Low Med Med High Low Low High High Med
Rooftop Low Low High Low Med High Low Med Med High Low Low Med High Med
Water-Source Heat Pumps High High Low Low Low Low High Low Low Low High High Low Low High
Geothermal Heat Pumps High High Low Low Low Low High Low Low Low High High Low Low High
7
waTer-SourCe HeaT pumpS
Water-Loop heat pump systems combine water-
source heat pumps on a common piping loop
with a heat rejector and boiler, which are used to
maintain the circulating water temperature within
a controlled range, typically from 60F to 95F
[15C to 35C]. The most common heat rejectors
are open cooling towers with isolating heat
exchangers, closed-circuit evaporative coolers, or
dry coolers. Boilers are usually gas, oil, or electric.
Each zone heat pump utilizes the water loop to
provide heating or cooling at any time, during or
after hours, regardless of the operating mode of
the other heat pumps. This is accomplished without
duplicate heat and cool distribution systems,
without the double waste inherent in reheat modes,
and without concurrent operation of the cooling
source and boiler, unlike most HVAC systems that
provide the same capabilities.
Water-loop heat pump systems also operate very
efciently at part-load conditions, such as when
a small portion of the building remains occupied
after hours. Only the required zone heat pumps
are used, unlike systems that must keep a large
central plant in operation at an inefcient scaled-
back capacity in order to serve a small portion of
the load.
A typical building has a perimeter with outside
exposure that is directly affected by variable
outdoor weather conditions and a core without
outside exposure that is almost unaffected by
the weather. In order to understand the energy
sharing benets of a water-source heat pump
system, the interaction of the loads in the core and
perimeter zones must be analyzed for occupied
periods (internal gains present) and unoccupied
periods (temperature setback/setup and little
or no internal gains) throughout the year. For
illustration, the following are the main energy
consuming operating modes of an ofce building
in a temperate climate.
Summer oCCupied
All zones require cooling and are rejecting heat
into the water loop. The heat rejector maintains the
maximum water loop temperature according to a
predetermined setpoint (xed or outdoor reset).
The boiler is off.
winTer warm-up
During recovery from night setback, most zones
will require heating and will be extracting heat
from the water loop. The boiler maintains the
minimum water loop temperature according to a
predetermined setpoint. The heat rejector is off.
The warm-up period is typically one hour or less
per day.
winTer oCCupied
Most core zones will require cooling because of
the internal heat gains discussed previously. Most
perimeter zones will require heating. Because heat
is being simultaneously rejected into and extracted
from the water loop, both the boiler and the heat
rejector remain off much of the time. The inherent
sharing of energy within the water loop minimizes
boiler and heat rejector operation and provides
maximum system efciency.
SoluTion 1
8
TCH120 TCH120
TLV168
TCH012 TCH012 TCH012 TCH012 TCH012
TCH048 TCH048 TCH048
TCH024 TCH024 TCH024 TCH024
TCH012
Office Office Office Office Office Office
Office Conference Room Restroom Breakroom Computer Room
Cubicles Cubicles
Lobby
Production Floor
M
e
c
h
a
n
ic
a
l
R
o
o
m
Cooling
Tower
Boiler
TCH120 TCH120
TLV168
TCH012 TCH012 TCH012 TCH012 TCH012
TCH048 TCH048 TCH048
TCH024 TCH024 TCH024 TCH024
TCH012
Office Office Office Office Office Office
Office Conference Room Restroom Breakroom Computer Room
Cubicles Cubicles
Lobby
Production Floor
M
e
c
h
a
n
ic
a
l
R
o
o
m
Cooling
Tower
Boiler
warm weaTHer (HigH Cooling demand)
Cool weaTHer (HigH HeaTing demand)
a waTer-SourCe example
As an example of how water-source heat pumps
can handle a variety of different applications, the
building shown to the right is a ctional bronze
statue foundry company in the midwest portion
of the United States. The rst oor comprises their
production oor and ofce space. The second
oor of the building is reserved for future use.
The cooling tower and boiler work as needed to
maintain an average loop temperature between 60
to 95F [15 to 35C]. Water-source heat pumps can
efciently operate in either heating or cooling mode
under these conditions. This gives individual and
specialized zone control for maximum comfort and
the ability to change operation modes as needed.
A mixture of units in heating mode and units
in cooling mode create a constant temperature
in the water loop. In Balanced Mode, there
is no need for heat injection or rejection via
the boiler or cooling tower. The heat is simply
moved from one zone to another.
SoluTion 1 example
9
geoTHermal SySTemS
These Boilerless/Towerless heat pump systems
use the natural thermal properties of the Earth
to dissipate or capture heat for the water loop.
Geothermal heat pumps operate in an identical
fashion to water-source heat pump units. However,
without the need for a boiler or cooling tower, they
save substantial energy costs and space. The water
loop system is underground and the units are inside
the building. Thus, the environmentally friendly
geothermal system preserves the architectural
design of a building naturally.
geoTHermal earTH loopS
Geothermal Earth Loops come in several different
congurations depending on space availability
and soil properties. Chances are at some point
you have either stood over, or walked across a
geothermal loop eld. Loop elds can be located
under parking lots, landscaped areas, or any
number of other locations. All earth loops use
high-density polyethylene pipe to circulate either
water or an antifreeze mixture. All joints and
connection ttings are thermally fused to prevent
leaks and most piping comes with a 25 year or
longer warranty.
VerTiCal loopS
Vertical loops utilize bore holes drilled to an
average depth of 250 feet. Once the loop
pipe is inserted into the bore, it is grouted
using a Bentonite mixture for maximum thermal
conductivity. When space is limited, vertical
loops are the most common type of geothermal
loop installed.
HorizonTal loopS
Horizontal loops utilize trenches dug to an average
depth of four to six feet. As one of the more cost
effective loops to install, horizontal loops are
commonly found in open elds, parks or under
parking lots.
lake loopS
Lake loops utilize a slinky assembly of
geothermal loop piping placed at the bottom of
a pond, lake, or other large body of water. An
extremely cost effective loop system, lake loops are
an easy alternative if the option is available.
well SySTemS
Most commonly known as Open Loop, well
systems pump water out of a nearby body of water
or water well, and then discharge the water into
another body of water or water well. Well systems
usually employ a plate heat exchanger inside the
building to keep the building water loop separated
from the well water. This prevents any contaminates
from affecting unit performance and extends system
life. Well systems are often the most efcient as
the well water is always at the same temperature
year-round.
SoluTion 2
10
warm weaTHer (HigH Cooling demand)
a geoTHermal example
Using the same building model, the cooling tower and
boiler are replaced with a geothermal vertical loop
eld. Identical in overall zone operation, the building
benets by having less overall equipment and reduced
operation costs. Building aesthetics are also improved
by eliminating outdoor equipment, and additional
space is gained by eliminating the boiler and additional
support equipment.
TCH120 TCH120
TLV168
TCH012 TCH012 TCH012 TCH012 TCH012
TCH048 TCH048 TCH048
TCH024 TCH024 TCH024 TCH024
TCH012
Office Office Office Office Office Office
Office Conference Room Restroom Breakroom Computer Room
Cubicles Cubicles
Lobby
Production Floor
S
t
o
r
a
g
e
The cooling tower and boiler can be eliminated in
the geothermal application freeing up space used for
equipment for other use. Only a small amount of room is
needed for loop circulation equipment.
SoluTion 2 example
12
wHo iS ClimaTemaSTer?
Who is ClimateMaster? ClimateMaster emerged
from the marriage of several water-source heat
pump companies in a blending of strengths to form
a focused organization. For over 50 years, we
have been focused on enhancing business and
home environments around the world. Our mission
as the worlds largest and most progressive leader
in the water-source and geothermal heat pump
industry reveals our commitment to excellence
- not only in the design and manufacture of our
products, but in our people and services.
made in THe uSa
All of ClimateMasters 610,000 square feet in
facilities operate in Oklahoma City, Oklahoma,
which means ClimateMaster units and components
are manufactured in the United States using
American labor. While the trend nationally is
to outsource labor outside the United States,
ClimateMaster has made the commitment to remain
proudly American made.
ClimaTemaSTer deSign
From concept to product, ClimateMasters
Integrated Product Development Team brings
a fusion of knowledge and creativity that is
unmatched in the industry today. Drawing from
every aspect of our business: Engineering, Sales,
Marketing, and Manufacturing, our Development
Team has created some of the most advanced,
efcient, and versatile products available.
innoVaTion, ConCepT, needS
Great products are born from necessity. Whether
it is a need to reduce sound, t in a smaller space,
make easier to service, achieve better efciencies,
or due to changing technologies, or new
government regulations, ClimateMaster leads the
industry in advancing the form, t and function of
water-source and geothermal
heat pumps. Our Design Team
continually strives for even the
slightest improvement to our
products. It is this continual
drive for excellence that sets
ClimateMaster apart from all
other manufacturers.
STarT To finiSH
At ClimateMaster, every product development
project begins with a comprehensive set of
specifications. These specifications are a
culmination of input from the market, a specific
need, or a number of other factors. From
these detailed specifications, prototypes are
constructed and testing begins. After a rigorous
testing period in ClimateMasters own state-of-
the-art lab facility, the data is compared to the
project specifications. Once the Design Team is
satisfied that all of the specs are met, the unit is
sent to the Production Department for pilot runs.
After the pilot runs are completed, unit literature
is finalized and the product is released to the
marketplace.
ClimaTemaSTer produCTion
Innovative products demand innovative manufacturing
processes. ClimateMasters
integrated production process
combines every aspect of the
manufacturing of our equipment
into an organized, balanced, and
controlled whole.
fabriCaTion
Every sheet-metal component of a ClimateMaster
unit is produced in our Fabrication Department.
Panels are precisely constructed of galvanized
or stainless steel using computerized cutting,
punching, and forming equipment. This precise
fabrication means a tighter t that makes for a
more solid unit and reduced vibration, which
equals reduced noise. On
certain series, an polyester
powder coating is then applied
to increase corrosion resistance
and enhance the look of
the unit. The nal step is the
addition of berglass insulation
to the inside as an additional layer of sound
deadening. This insulation meets stringent NFPA
regulations, and includes antibacterial material.
aSSembly
ClimateMasters 610,000 square foot facilities
use the most stringent quality control standards
in the industry. Each unit is assembled under
the close supervision of
our Integrated Process
Control System or Procix.
This multi-million dollar
computer system watches
each unit as it comes
down the assembly line.
In addition, our Quality Department is stationed
on each line and performs random audits not
only on the units, but also on component parts. All
component parts must pass each and every quality
checkpoint before a unit is packaged and shipped.
These systems and processes are maximized due
to the comprehensive and ongoing training every
employee receives from the date they are hired.
THe ClimaTemaSTer adVanTage
13
ComponenT parTS
To produce a quality unit,
you have to start with quality
components. ClimateMasters
Purchasing Department is
relentless in its search for
the best components for our
products - while securing
these components at prices that keep costs low.
Any new component must go through a grueling
testing phase before it ever sees the production
line. Working closely with vendors and their
engineers, we continually find new ways to not
only improve our units, but to ensure component
quality as well. Sister companies like KOAX,
who produce our coaxial heat exchangers,
allow ClimateMaster to provide components
specifically designed for our applications.
iSo 9001:2000 CerTifiCaTion
International Organization
for Standardization (ISO)
is a network of the national
standards institutes of
over 150 countries, on
the basis of one member per country, with a
Central Secretariat of Geneva, Switzerland,
that coordinates the system. ISO is a non-
governmental organization that occupies a
special position between the public and private
sectors whose goal is to create, maintain, and
improve standards worldwide. ISO standards
contribute to making the development,
manufacturing, and supply of products and
services more efficient, safer, and cleaner. ISO
certification demonstrates ClimateMasters
commitment to quality and continuous
improvement.
ClimaTemaSTer awardS
ClimateMaster leads the
industry in product awards
and certications. From 100%
Air-Conditioning, Heating
and Refrigeration Institute
(AHRI) performance ratings
to industry awards for innovation, ClimateMaster
applies cutting-edge technology to every product
we design and manufacture.

ClimateMasters Tranquility 27

Series has won
multiple awards and is widely accepted as a
leader in the industry. You know you are doing
great things when a lot of people tell you so.
engineering lab faCiliTieS
ClimateMaster has one of the largest testing
facilities of any water-source heat pump
manufacturer including the reverberant, ISO
3741 Certied sound testing room in the industry.
Innovation and product improvements are a
mainstay of the ClimateMaster Engineering Lab.
Our people are what make the difference in the
development of superior products in a timely
manner. Our certied facility has seven automated
test cells capable of testing a wide variety of unit
types under varying conditions. These cells are
capable of producing data twenty-four hours a
day, seven days a week. The development time
of equipment is signicantly reduced allowing
ClimateMaster Engineers and Lab Technicians
to spend more time on the actual development
process. This team effort has allowed us to maintain
a high degree of competence in our industry. Our
test cells and test equipment are calibrated and
certied periodically, per recognized industry
standards, to insure the data is accurate and
repeatable. In addition to testing new concept
units, the lab continually audits production units
throughout the year to insure quality performance
and reliability.
induSTry affiliaTionS
and aSSoCiaTionS
ClimateMaster works closely
with the International Standards
Organization (ISO), the American
Society of Heating, Refrigerating,
and Air Conditioning Engineers
(ASHRAE), and the Electrical Testing
Laboratories (ETL), to insure that
our equipment not only meets the
highest performance standards,
but meets the highest industry
standards as well. ClimateMaster
has celebrated many consecutive
years of 100% success rate in
AHRIs performance certication
program. An uncommon feat in the industry, this
is a testament to the craftsmanship, design, and
construction of every ClimateMaster unit.


CuSTomer SerViCe
ClimateMaster has
gone to great lengths
to meet our customers
business-to-business
needs. ClimateMaster
provides great products
and our customer support is second to none. Our
highly trained and experienced Customer Service
Department is available to assist you. Visit our
online Business Center or contact Tech Services for
any information you may need.
R
M
A
N
U
FA
C
TU
RER
CERTIFIEDTO ARI AS COM
PLY
IN
G
W
I T
H
IS
O
STANDARD 13256-1
HEAT PUMPS
W
ATER
TO
AIR BRINE
TO
A
I R

ISO 9001:2000
Certified
Quality: First & Always
14
ClimaTemaSTer.Com
Our web site has become the central hub for all of
our customers information needs. Current literature,
specications, presentations, and other resources
are readily available in an intuitive, easy-to-
navigate format. At the click of a mouse, our new
online Business Center allows you to check the
status of your orders, lookup sales history, manage
contact information, and even order literature,
accessories, and equipment. Combined with our
unique EZ-ORDER software, we take all the effort
and guesswork out of unit orders.
engineering deSign
SpeCifiCaTionS
Advanced units need advanced specications.
ClimateMasters new Engineering Design
specications provide the most detailed information
for your next project.
liTeraTure
At ClimateMaster, innovation never sleeps. As
new advances are made, and new products are
released, the need for accurate literature becomes
critical. Every piece of technical literature that
ClimateMaster produces is printed in our state-of-
the-art on-demand printing facility. What this means
is that we print only the literature we need at the
time we need it. This insures that only the most
current and accurate data is in the eld.
SHipping
When you need that critical service part or piece
of literature for your next presentation, you may
rest assured that ClimateMaster has a shipping
option for you. Networked with a variety of
carriers, we provide fast and reliable shipping to
anywhere in the world.
THe fuTure of
ClimaTemaSTer
Our long history of innovation has paved the
way for future endeavors with a solid platform
of success. Growing markets in Europe and Asia
demand a different way of not only manufacturing
our products, but also successfully marketing
them. Government regulations have phased
out R-22 refrigerant at the beginning of 2010
paving the way for new HFC-410A, a much more
environmentally friendly refrigerant. In looking
ahead, we continually strive for better processes,
better designs, and better innovations that will keep
ClimateMaster as the global leader in water-source
and geothermal heat pumps.
adVanTage exCluSiVeS
Being a leader in innovation, ClimateMaster brings
industry rsts, as well as industry exclusives, to our
family of products.
ConTrolS
ClimateMaster offers two levels of solid-state digital
controls; the CXM and DXM control board.
CXM
Our standard CXM control board comes
programmed with ClimateMasters Unit
Performance Sentinel (UPS) which monitors unit
performance and noties the owner of potential
unit problems before a lockout occurs. Additionally,
the CXMs eight standard safeties protect the unit
from damage.
Anti-Short Cycle
Low Voltage
High Voltage
High Refrigerant Pressure
Low Refrigerant Pressure
(Loss of Charge)
Air Coil Low
Temperature
Water Coil Low
Temperature
Condensate Overow
DXM
Our enhanced controls option, the DXM control
board offers all of the advantages of the CXM
board but adds the following additional features:
Multi-Stage Operation
Night Setback with
Override
Emergency Shutdown
Reheat Control
Boilerless Electric Heat
DDC Controls
Factory mounted LONWorks or Multi-ProtoCol
(MPC) DDC controllers are an available option
on all ClimateMaster products. These controllers
give owners the ability to implement a variety of
building automation systems
such as BACnet, ModBus,
and Johnson N2. Through a
web enabled PC, individual
units, unit zones, and entire
building systems can be
monitored and controlled
with the click of a mouse.
The systems provide unit status, set-point control,
performance curves, and fault indications.
15
ConfiguraTionS
No other manufacturer provides as many size,
performance, conguration, and cost options as
the ClimateMaster family of products offers. From
our smallest horizontal unit in the TCH-006, to
our largest vertical in the TLV-300, to our Rooftop
Series with available 100% make-up air (when
mated with the Rx ERV), to the vertical stack,
console, water-to-water, and two-stage Tranquility
27

, we have a unit to t your application.


Sound
Prior to the adoption of the 260-2000 sound
standard there had been no standard for the
evaluation of water-source heat pump sound
performance. Also, those manufacturers who did
generate and publish their own sound data, did
so in their own labs making it difcult to have
the data independently certied and accurate
comparisons were therefore, impossible. Now
that a standard has been established, it is critical
to compare the data correctly. If data from
two manufacturers is compared using different
test procedures, results are not comparable.
ClimateMaster has tested its product line for both
ducted discharge and free inlet air combined
with case radiated tests. Comfort has never been
so quiet with our intelligent sound design. Our
products use a variety of technologies to maintain
our lead as the quietest units in the industry.
dual leVel VibraTion
iSolaTion
ClimateMaster units use an
exclusive double isolation
compressor mounting system.
This dual level isolation
deadens vibration and
provides quiet operation.
TorSion-flex blowerS
Blower motors, on select models,
are mounted with a unique
torsion-ex mounting system
which not only allows for easy
service, but also reduces vibration
from the blower motor during
operation.
ulTraquieT
ClimateMasters optional additional sound
suppression package enhances our already
excellent sound performance through the use
of dual density acoustical insulation and other
strategically placed sound attenuating materials.
No other manufacturers mute package comes
close to matching the performance of the
UltraQuiet package.
e-CoaTed air CoilS
and waTer CoilS
All ClimateMaster water-source heating and
cooling systems are available with an E-Coated air-
coil option. E-Coated or Powder Coated water coils
are standard on all products. This process provides
years of protection against coil
corrosion from airborne chemicals
resulting from modern building
material outgassing and most
airborne environmental chemicals.
In fact, ClimateMasters exclusive
E-Coated air-coils enhance
corrosion protection to nearly 20
times that of a traditional uncoated coil.*
*Test based upon ASTM B117 Salt Spray test hours.
Climadry reHeaT
Continuing to lead the industry in IAQ (Indoor Air
Quality) solutions, select ClimateMaster units are
available with an innovative method (patented) of
reheating the air. The ClimaDry microprocessor-
controlled option will automatically provide 100%
reheat by adjusting the amount of reheat capacity
based upon supply air temperature. This new
approach to reheat provides dehumidied, neutral
temperature supply air, while eliminating the problem
of overcooling the space when loop temperatures
drop. All components are internal to the unit,
saving space and keeping installation costs low.
A simple humidistat or dehumidistat control activates
the option.
VolTageS
ClimateMaster units are available in a wide variety
of commercial voltages, providing maximum
exibility in building design. Available voltages are
as follows:
208-230/60/1
208-230/60/3
265/60/1
460/60/3
575/60/3
* Not all units are available with every voltage combination shown above.
aCCeSSorieS
ClimateMaster offers a complete line of
accessories to complete any project, including
hoses, thermostats, valves, pumps, ttings,
controllers, sensors, lters and more.
T H E C L I MAT E MA S T E R FA MI LY OF P R ODU C T S
Product Series
Standard Features Factory Installed Options
E
a
r
t
h
P
u
r
e

(H
F
C
-
4
1
0
A
) R
e
fr
ig
e
r
a
n
t
M
ic
r
o
p
r
o
c
e
s
s
o
r
C
X
M
C
o
n
t
r
o
ls
*
S
t
a
n
d
a
r
d
R
a
n
g
e
C
o
p
p
e
r
W
a
t
e
r
C
o
il*
*
T
X
V
D
u
a
l L
e
v
e
l C
o
m
p
r
e
s
s
o
r

V
ib
r
a
t
io
n
Is
o
la
t
io
n
F
ie
ld
C
o
n
v
e
r
t
ib
le
D
is
c
h
a
r
g
e

(H
o
r
iz
o
n
t
a
l U
n
it
s
)
M
u
lt
ip
le
A
c
c
e
s
s
P
a
n
e
ls
fo
r
In
s
t
a
lla
t
io
n

a
n
d
S
e
r
v
ic
e
E
a
s
e
S
c
r
o
ll C
o
m
p
r
e
s
s
o
r
s
F
a
c
t
o
r
y
In
s
t
a
lle
d
H
a
n
g
e
r
B
r
a
c
k
e
t
s

(H
o
r
iz
o
n
t
a
l U
n
it
s
)
R
e
m
o
t
e
R
e
s
e
t
a
t
T
h
e
r
m
o
s
t
a
t
C
o
n
d
e
n
s
a
t
e
O
v
e
r
f
lo
w
P
r
o
t
e
c
t
io
n
C
u
p
r
o
-
N
ic
k
e
l C
o
il
H
ig
h
S
t
a
t
ic
B
lo
w
e
r
U
lt
r
a
Q
u
ie
t
(M
u
t
e
) P
a
c
k
a
g
e
E
x
t
e
n
d
e
d
R
a
n
g
e
(2
0
t
o
1
2
0

F
)
A
u
t
o
-
F
lo
w
W
a
t
e
r
R
e
g
u
la
t
io
n
T
w
o
-
W
a
y
C
o
n
t
r
o
l V
a
lv
e
D
o
w
n
F
lo
w
C
o
n
f
ig
u
r
a
t
io
n
D
e
s
u
p
e
r
h
e
a
t
e
r
C
o
il
D
D
C
C
o
n
t
r
o
lle
r
D
e
lu
x
e
D
X
M
C
o
n
t
r
o
lle
r
E
-
C
o
a
t
e
d
A
ir
C
o
il
In
t
e
r
n
a
l S
e
c
o
n
d
a
r
y
P
u
m
p
E
C
M
F
a
n
*
*
*
C
lim
a
D
r
y
R
e
h
e
a
t
In
t
e
r
n
a
l S
e
r
v
ic
e
D
is
c
o
n
n
e
c
t
Tranquility 27

Two-Stage (TT)
Tranquility 20 Single-Stage (TS)
Tranquility High Efciency (TR) a
Tranquility 16 Compact (TC) a
Tranquility Vertical Stack (TRM) a
Tranquility Console (TRC)
Tranquility Compact (TCH)
Tranquility Large (TL) c
Tranquility Water-to-Water (TMW) b
Rooftop (TRE)
Rx Energy Recovery Ventilator (ERV)
Vertical Dedicated Outdoor Air (TO)
Horizontal Dedicated Outdoor Air (TO)
* Standard control for TO Series is DDC with modulating HGR.
** Standard water coil construction for TO Series is stainless steel.
*** Standard on TT Series
Standard on TMW Series
Extended Range = 35F95F EWT
a Sizes 024 and above
b Sizes 036 - 120
c Vertical series only
UNI T F E AT UR E S
R O O F T O P ( T R E ) S E R I E S
T h r e e t o T w e n t y T o n
R o o f t o p U n i t s
T R A N Q U I L I T Y V E R T I C A L
S T A C K ( T R M ) S E R I E S
T h r e e - Q u a r t e r t o T h r e e T o n
E a r t h P u r e

( H F C - 4 1 0 A ) V e r t i c a l
H i - R i s e S t a c k U n i t s
T R A N Q U I L I T Y ( T O H ) S E R I E S
T h r e e t o O n e H u n d r e d T o n
H o r i z o n t a l D e d i c a t e d O u t d o o r
A i r S y s t e m s
T R A N Q U I L I T Y ( T O V ) S E R I E S
F o u r t o T h i r t y T o n
V e r t i c a l D e d i c a t e d O u t d o o r
A i r S y s t e m s
T R A N Q U I L I T Y M O D U L A R
W A T E R - T O - W A T E R ( T M W ) S E R I E S
T h r e e t o T w e n t y - E i g h t T o n
E a r t h P u r e

( H F C - 4 1 0 A )
W a t e r - t o - W a t e r U n i t s
T R A N Q U I L I T Y C O N S O L E
( T R C ) S E R I E S
T h r e e - Q u a r t e r t o O n e - a n d - O n e H a l f T o n
E a r t h P u r e

( H F C - 4 1 0 A )
C o n s o l e U n i t s
T R A N Q U I L I T Y L A R G E
( T L ) S E R I E S
S e v e n t o T w e n t y - F i v e T o n
E a r t h P u r e

( H F C - 4 1 0 A )
V e r t i c a l U n i t s
T R A N Q U I L I T Y 2 0
S I N G L E - S T A G E ( T S ) S E R I E S
O n e - H a l f t o S i x T o n
S i n g l e - S t a g e E a r t h P u r e

( H F C - 4 1 0 A )
H o r i z o n t a l , V e r t i c a l , a n d D o w n f l o w U n i t s
T R A N Q U I L I T Y 2 7


T W O - S T A G E ( T T ) S E R I E S
T w o t o S i x T o n
T w o - S t a g e E a r t h P u r e

( H F C - 4 1 0 A )
H o r i z o n t a l , V e r t i c a l , a n d D o w n f l o w U n i t s
T R A N Q U I L I T Y 1 6
C O M P A C T ( T C ) S E R I E S
O n e - H a l f t o F i v e T o n
C o m p a c t E a r t h P u r e

( H F C - 4 1 0 A )
H o r i z o n t a l a n d V e r t i c a l U n i t s
T R A N Q U I L I T Y
C O M P A C T ( T C H ) S E R I E S
S i x t o T e n T o n
C o m p a c t E a r t h P u r e

( H F C - 4 1 0 A )
H o r i z o n t a l U n i t s
T R A N Q U I L I T Y
H I G H E F F I C I E N C Y ( T R ) S E R I E S
O n e - H a l f t o F i v e T o n
E a r t h P u r e

( H F C - 4 1 0 A )
H o r i z o n t a l a n d V e r t i c a l U n i t s
R x ( E R V ) M O D U L E
R o o f t o p E n e r g y
R e c o v e r y U n i t s
T H E C L I MAT E MA S T E R FA MI LY OF P R ODU C T S
20
The Tranquility 27

Two-Stage (TT) Series blends the


most advanced technology with the most advanced
design to create some of the highest efciency water-
source heat pumps available today.
The Tranquility 27

Two-Stage Series utilizes


EarthPure

(HFC-410A) refrigerant along with the


Copeland UltraTech two-stage compressor and
ECM variable speed motor to bring unmatched
performance and comfort.
uniT feaTureS
Sizes 026 (2 ton, 7.0 kW) through 072 (6 ton,
21.1 kW)
Environmentally-friendly EarthPure


HFC-410A refrigerant
Unsurpassed efciencies (far exceeds ASHRAE 90.1)
Copeland UltraTech two-stage compressor and
variable speed ECM fan motor
Galvanized steel construction and powder coat
paint on all units
Unique double isolation compressor mounting for
quiet operation
Discharge mufer standard on all sizes for
superior sound attenuation
Microprocessor controls standard (optional DXM
and/or DDC controls)
Field convertible discharge air arrangement for
horizontal units
Bi-directional, balanced port expansion valve
refrigerant metering device standard
Standard range or extended range operation
Water connections securely mounted ush to the
cabinet corner post (no backup wrench required)
Eight safeties standard
THe TranquiliTy 27

Two-STage (TT) SerieS


Easy to remove blower
housing for quick service
and ECM variable speed
motor
Foil faced insulation in the
blower section and berglass
insulation in the compressor
section
Copeland UltraTech two-
stage compressor
with dual compressor
vibration isolation
Easy service access from
multiple sides
Easy access control box
contains advanced digital
controls with Remote Service
Sentinel (Optional Enhanced
controls (DXM) & DDC
Controllers)
Factory installed hanger
brackets on horizontal units
Standard stainless steel
insulated drain pan with
condensate overow
protection
21
Model Refrigerant
Water Loop Heat Pump Ground Water Heat Pump Ground Loop Heat Pump
Cooling 86F [30C] Heating 68F [20C] Cooling 59F [15C] Heating 50F [10C] Cooling 77F [25C] Heating 32F [0C]
Capacity EER Capacity
COP
Capacity EER Capacity
COP
Capacity EER Capacity
COP
Btuh
[kW]
Btuh/W
[W/W]
Btuh
[kW]
Btuh
[kW]
Btuh/W
[W/W]
Btuh
[kW]
Btuh
[kW]
Btuh/W
[W/W]
Btuh
[kW]
TT-026 HFC-410A 25,300 [7.42] 15.9 [4.7] 30,800 [9.03] 5.3 28,900 [8.47] 24.5 [7.2] 25,700 [7.53] 4.8 26,600 [7.80] 18.5 [5.4] 19,800 [5.80] 4.0
TT-038 HFC-410A 36,200 [10.61] 15.6 [4.6] 44,800 [13.13] 5.3 41,200 [12.08] 23.0 [6.7] 36,700 [10.76] 4.7 38,200 [11.20] 18.2 [5.3] 29,000 [8.50] 4.0
TT-049 HFC-410A 48,400 [14.19] 15.7 [4.6] 59,900 [4.19] 5.2 54,600 [16.00] 22.5 [6.6] 48,300 [14.16] 4.7 50,600 [14.83] 17.9 [5.2] 37,500 [10.99] 4.0
TT-064 HFC-410A 61,500 [18.03] 15.0 [4.4] 72,300 [21.19] 5.0 68,600 [20.11] 22.0 [6.4] 59,600 [17.47] 4.4 64,800 [18.99] 17.5 [5.1] 48,000 [14.07] 3.9
TT-072 HFC-410A 68,700 [20.14] 14.2 [4.2] 88,600 [25.97] 4.9 77,100 [22.60] 19.9 [5.8] 70,200 [20.57] 4.3 71,600 [20.99] 16.2 [4.7] 54,100 [15.86] 3.6
performanCe and SpeCifiCaTionS
Full Load AHRI/ISO/ASHRAE 13256-1 Data (English (IP) Units & Metric (SI) Units)
Cooling capacities based upon 80.6F [27C] DB, 66.2F [19C] WB entering air temperature.
Heating capacities based upon 68F [20C] DB, 59F [15C] WB entering air temperature.
All ratings based upon operation at the lower voltage of dual voltage rated models.
Dimensional Data
Vertical
Upow
Model
Overall Cabinet
W D H
026
in.
cm
22.4
56.8
25.6
65.1
48.5
123.2
038
in.
cm
25.4
64.5
30.6
77.8
50.5
128.3
049
in.
cm
25.4
64.5
30.6
77.8
54.5
138.4
064
in.
cm
25.4
64.5
30.6
77.8
58.5
148.6
072
in.
cm
25.4
64.5
30.6
77.8
58.5
148.6
Horizontal
Model
Overall Cabinet
W D H
026
in.
cm
22.4
56.8
62.2
158.0
19.3
48.9
038
in.
cm
25.4
64.5
71.2
180.8
21.3
54.0
049
in.
cm
25.4
64.5
76.2
193.5
21.3
54.0
064
in.
cm
25.4
64.5
81.2
206.2
21.3
54.0
072
in.
cm
25.4
64.5
81.2
206.2
21.3
54.0
Model Refrigerant
Water Loop Heat Pump Ground Water Heat Pump Ground Loop Heat Pump
Cooling 86F [30C] Heating 68F [20C] Cooling 59F [15C] Heating 50F [10C] Cooling 77F [25C] Heating 32F [0C]
Capacity EER Capacity
COP
Capacity EER Capacity
COP
Capacity EER Capacity
COP
Btuh
[kW]
Btuh/W
[W/W]
Btuh
[kW]
Btuh
[kW]
Btuh/W
[W/W]
Btuh
[kW]
Btuh
[kW]
Btuh/W
[W/W]
Btuh
[kW]
TT-026 HFC-410A 19,400 [5.69] 18.3 [5.4] 22,400 [6.57] 6.1 22,200 [6.51] 30.8 [9.0] 18,600 [5.45] 5.1 21,300 [6.24] 26.0 [7.6] 16,500 [4.83] 4.6
TT-038 HFC-410A 26,200 [7.68] 18.5 [5.4] 30,800 [9.03] 6.3 30,200 [8.85] 31.5 [9.2] 24,800 [7.27] 5.1 28,900 [8.47] 27.0 [7.9] 22,100 [6.48] 4.5
TT-049 HFC-410A 36,100 [10.58] 18.0 [5.3] 44,300 [12.98] 6.2 40,700 [11.93] 28.7 [8.4] 35,400 [10.38] 5.1 39,600 [11.61] 24.9 [7.3] 31,200 [9.14] 4.6
TT-064 HFC-410A 44,900 [13.16] 17.6 [5.2] 51,100 [14.98] 5.7 51,900 [15.21] 29.7 [8.7] 49,800 [12.25] 4.7 49,800 [14.60] 25.3 [7.4] 37,500 [10.99] 4.3
TT-072 HFC-410A 52,800 [15.48] 16.0 [4.7] 65,200 [19.11] 5.1 59,800 [17.53] 24.5 [7.2] 51,700 [15.15] 4.3 57,700 [16.91] 21.4 [6.3] 45,400 [13.31] 3.9
Part Load AHRI/ISO/ASHRAE 13256-1 Data (English (IP) Units & Metric (SI) Units)
Note: Add 4 [10.16cm] to height for
vertical downow models.
Voltage Options
Model Volts Hz Phase
026 208/230 60 1
038 - 064
208/230
208/230
460
60
60
60
1
3
3
072 208/230 60 1
22
The Tranquility 20 Single-Stage (TS) Series builds
on ClimateMasters commitment to utilizing the most
advanced technology and design to create one
of the most efcient single-stage water-source heat
pump available today. The Tranquility 20 Single-
Stage Series combines EarthPure

(HFC-410A)
refrigerant with the Copeland Scroll compressor
(rotary in 018 and smaller) and either an ECM
variable speed or PSC multi-speed fan motor to
create unmatched performance and exibility.
uniT feaTureS
Sizes 006 (1/2 ton, 1.8 kW) through 070 (6 ton,
21.1 kW)
Environmentally-friendly EarthPure


(HFC-410A) refrigerant
Unsurpassed efciencies (far exceeds ASHRAE 90.1)
Copeland Scroll compressor (size 018 and above)
Multi-speed PSC fan motor (optional variable
speed ECM motor on size 018 and above)
Galvanized steel construction and powder coat
paint on all units
Unique double isolation compressor mounting for
quiet operation
Discharge mufer standard (except rotary
compressors) for superior sound attenuation
Microprocessor controls standard (optional DXM
and/or DDC controls)
Field convertible discharge air arrangement for
horizontal units
Bi-directional, balanced port expansion valve
refrigerant metering device standard
Standard range or extended range operation
Water connections securely mounted ush to the
cabinet corner post (no backup wrench required)
Eight safeties standard
THe TranquiliTy 20 Single-STage (TS) SerieS
Easy to remove blower
housing for quick service
and optional ECM
variable speed motor
Foil faced insulation in
the blower section and
berglass insulation in
the compressor section
Dual compressor
vibration isolation for
quiet operation
Easy service access from
multiple sides
Easy access control
box contains advanced
digital controls with
Remote Service Sentinel
(Optional Enhanced
controls (DXM) & DDC
Controllers)
Factory installed
hanger brackets on
horizontal units
Standard stainless steel
insulated drain pan with
condensate overow
protection
23
performanCe and SpeCifiCaTionS
AHRI/ISO/ASHRAE 13256-1 Data (English (IP) Units & Metric (SI) Units)
Dimensional Data
Model* Refrigerant
Water Loop Heat Pump Ground Water Heat Pump Ground Loop Heat Pump
Cooling 86F [30C] Heating 68F [20C] Cooling 59F [15C] Heating 50F [10C] Cooling 77F [25C] Heating 32F [0C]
Capacity EER Capacity
COP
Capacity EER Capacity
COP
Capacity EER Capacity
COP
Btuh
[kW]
Btuh/W
[W/W]
Btuh
[kW]
Btuh
[kW]
Btuh/W
[W/W]
Btuh
[kW]
Btuh
[kW]
Btuh/W
[W/W]
Btuh
[kW]
TS-006 PSC HFC-410A 6,300 [1.85] 15.7 [4.6] 8,000 [2.34] 5.4 7,400 [2.17] 25.5 [7.5] 6,300 [1.85] 4.4 6,700 [1.96] 18.5 [5.4] 4,800 [1.41] 3.4
TS-009 PSC HFC-410A 9,300 [2.74] 15.3 [4.5] 11,100 [3.26] 4.8 11,100 [3.26] 25.2 [7.4] 9,400 [2.76] 4.3 10,000 [2.94] 18.1 [5.3] 7100 [2.09] 3.4
TS-012 PSC HFC-410A 11,700 [3.43] 15.4 [4.5] 13,800 [4.05] 4.5 13,300 [3.90] 24.6 [7.2] 11,800 [3.46] 4.0 12,300 [3.60] 18.1 [5.3] 9,500 [2.78] 3.5
TS-018 PSC
TS-018 ECM
HFC-410A
18,600 [5.47]
19,200 [5.65]
15.0 [4.4]
16.5 [4.8]
23,000 [6.76]
23,300 [6.85]
5.2
5.9
21,300 [6.26]
22,100 [6.50]
24.8 [7.3]
26.3 [7.7]
18,800 [5.53]
18,900 [5.56]
4.5
4.9
19,500 [5.74]
20,200 [5.94]
18.4 [5.4]
19.4 [5.5]
14,500 [4.27]
14,500 [4.43]
3.6
3.9
TS-024 PSC
TS-024 ECM
HFC-410A
25,100 [7.36]
25,000 [7.33]
16.2 [4.8]
17.0 [5.0
29,600 [8.68]
30,000 [8.79]
4.9
5.3
28,600 [8.38]
28,100 [8.24]
25.7 [7.5]
27.4 [8.0]
25,000 [7.33]
25,100 [7.36]
4.3
4.6
26,300 [7.71]
26,000 [7.62]
19.1 [5.6]
20.0 [5.0]
19,000 [5.57]
19,400 [5.69]
3.7
3.8
TS-030 PSC
TS-030 ECM
HFC-410A
28,200 [8.26]
28,600 [8.38]
15.3 [4.5]
15.6 [4.6]
34,900 [10.23]
35,200 [10.32]
5.0
5.3
31,700 [9.29]
32,200 [9.44]
22.9 [6.7]
23.9 [7.0]
29,400 [8.62]
29,400 [8.62]
4.4
4.6
29,400 [8.62]
29,800 [8.73]
17.6 [5.2]
18.0 [5.3]
23,600 [6.92]
23,700 [6.95]
3.8
3.9
TS-036 PSC
TS-036 ECM
HFC-410A
33,000 [9.67]
33,100 [9.70]
16.6 [4.9]
17.6 [5.2]
39,800 [11.66]
39,500 [11.58]
5.5
5.8
37,300 [10.93]
37,300 [10.93]
25.1 [7.4]
26.5 [7.8]
32,900 [9.64]
32,900 [9.64]
4.8
5.1
34,500 [10.11]
34,600 [10.14]
19.2 [5.6]
20.2 [5.9]
25,700 [7.53]
25,800 [7.56]
3.9
4.2
TS-042 PSC
TS-042 ECM
HFC-410A
37,400 [10.96]
37,800 [11.08]
16.0 [4.7]
17.1 [5.0]
49,400 [14.48]
48,600 [14.24]
5.4
5.7
42,900 [12.57]
44,200 [12.95]
24.3 [7.1]
27.1 [7.9]
40,100 [11.75]
39,300 [11.52]
4.6
4.9
39,300 [11.52]
40,000 [11.72]
18.4 [5.4]
20.0 [5.9]
31,600 [9.26]
30,400 [8.91]
3.8
4.0
TS-048 PSC
TS-048 ECM
HFC-410A
47,000 [13.77]
47,600 [13.95]
15.3 [4.5]
15.9 [4.7]
60,000 [17.58]
59,700 [17.50]
5.0
5.2
53,900 [15.80]
54,100 [15.86]
23.3 [6.8]
24.6 [7.2]
49,000 [14.36]
48,700 [14.27]
4.4
4.5
49,900 [14.62]
50,100 [14.68]
17.6 [5.2]
18.5 [5.4]
39,000 [11.43]
38,400 [11.25]
3.7
3.8
TS-060 PSC
TS-060 ECM
HFC-410A
61,000 [17.88]
62,000 [17.88]
15.9 [4.7]
16.4 [4.8]
70,400 [20.63]
70,800 [20.75]
5.0
5.2
67,000 [19.64]
67,200 [19.70]
23.2 [6.8]
24.3 [7.1]
58,700 [17.20]
59,100 [17.32]
4.5
4.6
63,300 [18.55]
64,000 [18.76]
18.2 [5.3]
19.0 [5.6]
46,500 [13.63]
46,700 [13.69]
3.7
3.8
TS-070 PSC
TS-070 ECM
HFC-410A
67,500 [19.78]
67,000 [19.64]
14.4 [4.2]
15.2 [4.5]
85,800 [25.15]
84,900 [24.88]
5.0
5.0
77,100 [22.60]
77,000 [22.57]
21.6 [6.3]
23.5 [6.9]
69,400 [20.34]
69,000 [20.22]
4.3
4.4
70,800 [20.75]
70,000 [20.52]
16.6 [4.9]
17.8 [5.2]
54,000 [15.83]
53,900 [15.80]
3.6
3.6
Vertical
Upow
Model
Overall Cabinet
W D H
006 -
012
in.
cm
22.4
56.8
21.6
54.9
34.5
87.6
018
in.
cm
22.4
56.8
25.6
65.1
44.5
113.0
024 -
030
in.
cm
22.4
56.8
25.6
65.1
48.5
123.2
036
in.
cm
25.4
64.5
30.6
77.8
50.5
128.3
042-
048
in.
cm
25.4
64.5
30.6
77.8
54.5
138.4
060 -
070
in.
cm
25.4
64.5
30.6
77.8
58.5
148.6
Horizontal
Model
Overall Cabinet
W D H
006 -
012
in.
cm
22.4
56.8
43.1
109.5
17.3
43.9
018 -
030
in.
cm
22.4
56.8
62.2
158.0
19.3
49.0
036
in.
cm
25.4
64.5
71.2
180.8
21.3
54.1
042 -
048
in.
cm
25.4
64.5
76.2
193.5
21.3
54.1
060 -
070
in.
cm
25.4
64.5
81.2
206.2
21.3
54.1
Cooling capacities based upon 80.6F [27C] DB, 66.2F [19C] WB entering air temperature.
Heating capacities based upon 68F [20C] DB, 59F [15C] WB entering air temperature.
All ratings based upon operation at the lower voltage of dual voltage rated models.
* ECM motor available on sizes 018 and larger.
Note: Add 4 [10.16cm] to height for vertical downow models.
Voltage Options
Model Volts Hz Phase
06 - 018
208/230
265
60
60
1
1
024 -
036
208/230
265
208/230
460
60
60
60
60
1
1
3
3
042 -
070
208/230
208/230
460
575
60
60
60
60
1
3
3
3
24
The Tranquility High Efciency (TR) Series offers high
efcient performance in a simple cabinet design.
The Tranquility High Efciency Series also offers
options that allow for application exibility. Available
options include ClimaDry dehumidication, hot
water generator, enhanced controls, e-coated
air coils, extended range insulation, UltraQuiet
package, secondary circulating pump, motorized
water valve, automatic water ow valves and high
static blowers.
uniT feaTureS
Sizes 006 (1/2 ton, 1.8 kW) through 060
(5 tons, 17.6 kW)
Exceeds ASHRAE 90.1 efciencies
Galvanized steel construction with attractive matte
black epoxy powder coat paint front access panel
Epoxy powder painted galvanized steel drain pan
Sound absorbing glass ber insulation
Unique double isolation compressor mounting for
quiet operation
Insulated divider and separate compressor/air
handler compartments
Copeland scroll compressors (Size 018 and
above)
Microprocessor controls standard (optional DXM
and/or DDC controls)
Field convertible discharge air arrangement for
horizontal units
PSC three-speed fan motor
Internally trapped condensate drain line (vertical
units only)
Eight safeties standard
Extended range (20 to 120F, -6.7 to 48.9C)
capable
THe TranquiliTy HigH effiCienCy (Tr) SerieS
Dual compressor vibration
isolation for quiet operation
Easy access control box
contains advanced digital
controls with Remote Service
Sentinel Optional Enhanced
controls (DXM) & DDC
Controllers
Epoxy powder painted
drain pan with condensate
overow protection
Factory installed hanger
brackets on horizontal units
Easy to remove blower
housing for quick service and
PSC three-speed fan motor
Easy service access
from multiple sides
25
Model Refrigerant
Water Loop Heat Pump Ground Water Heat Pump Ground Loop Heat Pump
Cooling 86F [30C] Heating 68F [20C] Cooling 59F [15C] Heating 50F [10C] Cooling 77F [25C] Heating 32F [0C]
Capacity EER Capacity
COP
Capacity EER Capacity
COP
Capacity EER Capacity
COP
Btuh
[kW]
Btuh/W
[W/W]
Btuh
[kW]
Btuh
[kW]
Btuh/W
[W/W]
Btuh
[kW]
Btuh
[kW]
Btuh/W
[W/W]
Btuh
[kW]
TR-006 HFC-410A 5,800 [1.70] 13.2 [3.9] 7,500 [2.20] 4.7 6,900 [2.02] 21.1 [6.2] 6,200 [1.82] 4.0 6,200 [1.82] 15.4 [4.5] 4,900 [1.44] 3.4
TR-009 HFC-410A 8,800 [2.58] 13.4 [3.9] 11,600 [3.40] 4.2 10,100 [2.96] 21.0 [6.2] 9,800 [2.87] 3.9 9,300 [2.72] 15.7 [4.6] 7,900 [2.31] 3.4
TR-012 HFC-410A 11,700 [3.43] 13.5 [4.0] 15,200 [4.45] 4.3 13,700 [4.01] 20.8 [6.1] 12,500 [3.66] 3.8 12,000 [3.52] 14.9 [4.4] 9,900 [2.90] 3.2
TR-015 HFC-410A 14,500 [4.25] 15.4 [4.5] 17,300 [5.07] 5.0 16,800 [4.92] 24.5 [7.2] 14,400 [4.22] 4.4 15,000 [4.39] 17.2 [5.0] 11,100 [3.25] 3.6
TR-018 HFC-410A 17,300 [5.07] 14.3 [4.2] 21,500 [6.30] 5.0 20,600 [6.04] 24.2 [7.1] 17,200 [5.04] 4.4 18,400 [5.39] 16.3 [4.8] 13,900 [4.07] 3.4
TR-024 HFC-410A 23,700 [6.94] 13.4 [3.9] 28,500 [8.35] 4.7 26,700 [7.82] 20.9 [6.1] 24,000 [7.03] 4.1 24,900 [7.30] 15.4 [4.5] 18,500 [5.42] 3.3
TR-030 HFC-410A 28,100 [8.23] 13.4 [3.9] 35,100 [10.28] 4.6 31,700 [9.29] 20.1 [5.9] 29,600 [8.67] 4.1 28,900 [8.47] 15.1 [4.4] 23,400 [6.86] 3.4
TR-036 HFC-410A 34,500 [10.11] 13.5 [4.0] 45,200 [13.24] 4.4 38,700 [11.34] 20.7 [6.1] 37,500 [10.99] 4.0 35,300 [10.34] 14.9 [4.4] 29,600 [8.67] 3.3
TR-042 HFC-410A 40,100 [11.75] 13.1 [3.8] 52,700 [15.44] 4.3 45,900 [13.45] 19.6 [5.7] 44,000 [12.89] 3.8 40,500 [11.87] 14.4 [4.2] 34,300 [10.05] 3.2
TR-048 HFC-410A 47,700 [13.98] 13.3 [3.9] 55,900 [16.38] 4.7 54,300 [15.91] 20.5 [6.0] 46,500 [13.62] 4.1 49,000 [14.36] 14.7 [4.3] 36,400 [10.67] 3.4
TR-060 HFC-410A 59,400 [17.40] 13.4 [3.9] 77,000 [22.58] 4.3 66,600 [19.51] 19.9 [5.8] 64,000 [18.75] 3.8 60,100 [17.61] 14.8 [4.3] 50,500 [14.80] 3.1
performanCe and SpeCifiCaTionS
AHRI/ISO/ASHRAE 13256-1 Data (English (IP) Units & Metric (SI) Units)
Cooling capacities based upon 80.6F [27C] DB, 66.2F [19C] WB entering air temperature.
Heating capacities based upon 68F [20C] DB, 59F [15C] WB entering air temperature.
All ratings based upon operation at the lower voltage of dual voltage rated models.
Dimensional Data
Vertical Upow
Model
Overall Cabinet
W D H
006 - 012
in.
cm
22.5
57.2
21.3
54.1
22.5
57.2
015 - 030
in.
cm
22.4
56.9
22.4
56.9
40.5
102.9
036 - 042
in.
cm
22.4
56.9
25.4
64.5
46.5
118.1
048 - 060
in.
cm
25.4
64.5
29.1
73.9
50.5
128.3
Horizontal
Model
Overall Cabinet
W D H
006 - 012
in.
cm
22.5
57.2
40.3
102.4
11.5
29.2
015 - 030
in.
cm
22.4
56.9
48.3
122.7
17.5
44.5
036 - 042
in.
cm
22.4
56.9
53.1
134.9
21.3
54.1
048 - 060
in.
cm
25.4
64.5
67.9
172.5
21.3
54.1
Voltage Options
Model Volts Hz Phase
006 - 024
208/230
265
60
60
1
1
030 - 036
208/230
265
208/230
460
60
60
60
60
1
1
3
3
042 - 060
208/230
208/230
460
575
60
60
60
60
1
3
3
3
26
The Tranquility 16 Compact (TC) Series raises
the bar for water-source heat pump efciencies,
features and application exibility. Not only does the
Tranquility 16 Compact Series exceed ASHRAE 90.1
efciencies, but it also uses EarthPure

(HFC-410A)
zero ozone depletion refrigerant, making it
an extremely environmentally-friendly option.
With one of the smallest cabinets in the industry, the
Tranquility 16 Compact (TC) Series will easily t into
tight spaces. Designed to be backward compatible
with thousands of older water-source heat pumps,
the Tranquility 16 Compact (TC) Series heat pump
is packed full of the innovation you have come to
expect from the experts at ClimateMaster.
uniT feaTureS
Sizes 006 (1/2 ton, 1.8 kW) through 060 (5 tons,
17.6 kW)
EarthPure

(HFC-410A) refrigerant
Exceeds ASHRAE 90.1 efciencies
Galvanized steel construction with attractive matte
black epoxy powder coat paint front access panel
Epoxy powder painted galvanized steel drain pan
Sound absorbing glass ber insulation
Unique double isolation compressor mounting for
quiet operation
Insulated divider and separate compressor/air
handler compartments
Copeland scroll compressors (size 018 and above)
TXV metering device
Microprocessor controls standard (optional DXM
and/or DDC controls)
Field convertible discharge air arrangement for
horizontal units
THe TranquiliTy 16 CompaCT (TC) SerieS
Dual compressor vibration
isolation for quiet operation
Easy access control box
contains advanced digital
controls with Remote Service
Sentinel Optional Enhanced
controls (DXM) & DDC
Controllers
Epoxy powder painted
drain pan with condensate
overow protection
Factory installed hanger
brackets on horizontal units
Easy to remove blower
housing for quick service and
PSC three-speed fan motor
Easy service access from
multiple sides
27
performanCe and SpeCifiCaTionS
Dimensional Data Voltage Options
Model Volts Hz Phase
006 - 024
208/230
265
60 1
030 - 036
208/230
265
208/230
460
60
60
60
60
1
1
3
3
042 - 060
208/230
208/230
460
575
60
60
60
60
1
3
3
3
Horizontal
Model
Overall Cabinet
Width Length Height
006 - 012
in.
cm
19.1
48.5
34.1
86.6
11.1
28.2
015 - 018
in.
cm
20.1
51.1
43.1
109.5
17.0
43.2
024 - 030
in.
cm
20.1
51.1
43.1
109.5
18.3
46.5
036 - 042
in.
cm
20.1
51.1
47.1
119.6
21.0
53.3
048 - 060
in.
cm
24.1
61.2
54.1
137.4
21.0
53.3
072 - 120
in.
cm
36.3
92.2
84.9
215.6
21.0
54.9
Vertical
Uplow
Model
Overall Cabinet
Width Depth Height
006 - 012
in.
cm
19.1
48.5
19.1
48.5
22.0
55.9
015 - 018
in.
cm
21.5
54.6
21.5
54.6
40.0
101.6
024 - 030
in.
cm
21.5
54.6
21.5
54.6
45.0
114.3
036 - 042
in.
cm
21.5
54.6
26.0
66.0
44.0
111.8
048 - 060
in.
cm
24.0
61.0
29.1
73.9
50.5
128.3
Model Refrigerant
Water Loop Heat Pump Ground Water Heat Pump Ground Loop Heat Pump
Cooling 86F [30C] Heating 68F [20C] Cooling 59F [15C] Heating 50F [10C] Cooling 77F [25C] Heating 32F [0C]
Capacity EER Capacity
COP
Capacity EER Capacity
COP
Capacity EER Capacity
COP
Btuh
[kW]
Btuh/W
[W/W]
Btuh
[kW]
Btuh
[kW]
Btuh/W
[W/W]
Btuh
[kW]
Btuh
[kW]
Btuh/W
[W/W]
Btuh
[kW]
TC-006 HFC-410A 5,800 [1.70] 13.2 [3.9] 7,500 [2.20] 4.7 6,900 [2.02] 21.1 [6.2] 6,200 [1.82] 4.0 6,200 [1.82] 15.4 [4.5] 4,900 [1.44] 3.4
TC-009 HFC-410A 8,800 [2.58] 13.4 [3.9] 11,600 [3.40] 4.2 10,100 [2.96] 21.0 [6.2] 9,800 [2.87] 3.9 9,300 [2.72] 15.7 [4.6] 7,900 [2.31] 3.4
TC-012 HFC-410A 11,700 [3.43] 13.5 [4.0] 15,200 [4.45] 4.3 13,700 [4.01] 20.8 [6.1] 12,500 [3.66] 3.8 12,000 [3.52] 14.9 [4.4] 9,900 [2.90] 3.2
TC-015 HFC-410A 14,500 [4.25] 15.4 [4.5] 17,300 [5.07] 5.0 16,800 [4.92] 24.5 [7.2] 14,400 [4.22] 4.4 15,000 [4.39] 17.2 [5.0] 11,100 [3.25] 3.6
TC-018 HFC-410A 17,300 [5.07] 14.3 [4.2] 21,500 [6.30] 5.0 20,600 [6.04] 24.2 [7.1] 17,200 [5.04] 4.4 18,400 [5.39] 16.3 [4.8] 13,900 [4.07] 3.4
TC-024 HFC-410A 23,700 [6.94] 13.4 [3.9] 28,500 [8.35] 4.7 26,700 [7.82] 20.9 [6.1] 24,000 [7.03] 4.1 24,900 [7.30] 15.4 [4.5] 18,500 [5.42] 3.3
TC-030 HFC-410A 28,100 [8.23] 13.4 [3.9] 35,100 [10.28] 4.6 31,700 [9.29] 20.1 [5.9] 29,600 [8.67] 4.1 28,900 [8.47] 15.1 [4.4] 23,400 [6.86] 3.4
TC-036 HFC-410A 34,500 [10.11] 13.5 [4.0] 45,200 [13.24] 4.4 38,700 [11.34] 20.7 [6.1] 37,500 [10.99] 4.0 35,300 [10.34] 14.9 [4.4] 29,600 [8.67] 3.3
TC-042 HFC-410A 40,100 [11.75] 13.1 [3.8] 52,700 [15.44] 4.3 45,900 [13.45] 19.6 [5.7] 44,000 [12.89] 3.8 40,500 [11.87] 14.4 [4.2] 34,300 [10.05] 3.2
TC-048 HFC-410A 47,700 [13.98] 13.3 [3.9] 55,900 [16.38] 4.7 54,300 [15.91] 20.5 [6.0] 46,500 [13.62] 4.1 49,000 [14.36] 14.7 [4.3] 36,400 [10.67] 3.4
TC-060 HFC-410A 59,400 [17.40] 13.4 [3.9] 77,000 [22.58] 4.3 66,600 [19.51] 19.9 [5.8] 64,000 [18.75] 3.8 60,100 [17.61] 14.8 [4.3] 50,500 [14.80] 3.1
AHRI/ISO/ASHRAE 13256-1 Data (English (IP) Units & Metric (SI) Units)
Cooling capacities based upon 80.6F [27C] DB, 66.2F [19C] WB entering air temperature.
Heating capacities based upon 68F [20C] DB, 59F [15C] WB entering air temperature.
All ratings based upon operation at the lower voltage of dual voltage rated models.
28
Installed System
The Tranquility Vertical Stack (TRM) Series offers an
innovative, labor-saving solution for spaces where
individual, quiet control of the heating and cooling
system is important. Using EarthPure

(HFC-410A)
refrigerant, the Tranquility Vertical Stack (TRM)
Series not only protects the environment, it does so
while delivering unprecedented comfort, efciency,
and reliability.
uniT feaTureS
Sizes 09 (3/4 ton, 2.6 kW) through 36 (3 ton,
10.6 kW)
Environmentally-friendly EarthPure

(HFC-410A)
zero ozone depletion refrigerant
High efciency rotary and scroll compressors
Exceeds ASHRAE 90.1 efciencies
Removable chassis allows staged installation and
ease of maintenance
Galvanized steel cabinet
Unique double isolation compressor mounting for
quiet operation
TXV metering device
Unit or remote-mounted controls available
Microprocessor controls standard (optional DXM
and/or DDC controls)
LonWorks, BACnet, Modbus and Johnson N2
compatibility options for DDC controls
Unit Performance Sentinel performance
monitoring system
Attractive return air panel with hinged access door
(G panel)
Multiple supply air discharge options
Stainless steel braided hose kits for connection
from piping risers to chassis
Eight safeties standard
Wide variety of options including disconnect
switch and extended range
TranquiliTy VerTiCal STaCk (Trm) SerieS
Exclusive dual-level
compressor isolation
lowers vibration and
reduces noise for quiet
operation
Removable chassis allows
staged installation and
ease of maintenance/
service once installation is
complete
Advanced digital controls
with Remote Service
Sentinel. Shown with
optional DDC Controller
(Optional Enhanced
controls (DXM) also
available)
Integrated Drain Pan with
condensate overow
protection (Optional
Stainless Steel Drain Pan)
Torsion-ex blower motors
TRM09-12
29
Model Refrigerant
Water Loop Heat Pump Ground Water Heat Pump Ground Loop Heat Pump
Cooling 86F [30C] Heating 68F [20C] Cooling 59F [15C] Heating 60F [10C] Cooling 77F [25C] Heating 32F [0C]
Capacity EER Capacity
COP
Capacity EER Capacity
COP
Capacity EER Capacity
COP
Btuh
[kW]
Btuh/W
[W/W]
Btuh
[kW]
Btuh
[kW]
Btuh/W
[W/W]
Btuh
[kW]
Btuh
[kW]
Btuh/W
[W/W]
Btuh
[kW]
TRM-09 HFC-410A 8,800 [2.58] 13.0 [3.8] 12,500 [3.66] 4.6 10,100 [2.93] 19.5 [5.7] 9,800 [2.87] 3.8 9,300 [2.73] 14.7 [4.3] 7,200 [2.11] 3.1
TRM-12 HFC-410A 11,600 [3.40] 13.0 [3.8] 15,800 [4.63] 4.5 13,700 [4.02] 20.0 [5.9] 12,700 [3.72] 3.8 12,200 [3.58] 15.0 [4.4] 9,500 [2.78] 3.1
TRM-15 HFC-410A 13,800 [4.05] 13.0 [3.8] 19,600 [5.74] 4.7 16,500 [4.84] 20.0 [5.9] 15,500 [4.54] 3.9 15,200 [4.46] 14.6 [4.3] 11,500 [3.37] 3.1
TRM-18 HFC-410A 16,700 [4.89] 13.0 [3.8] 22,600 [6.62] 4.7 19,600 [5.74] 19.5 [5.7] 18,200 [5.33] 3.8 17,600 [5.16] 14.6 [4.3] 14,000 [4.10] 3.1
TRM-24 HFC-410A 22,100 [6.48] 13.0 [3.8] 29,400 [8.62] 4.5 26,400 [7.74] 20.0 [5.9] 23,100 [6.77] 3.8 23,600 [6.92] 14.8 [4.3] 18,000 [5.28] 3.1
TRM-30 HFC-410A 27,100 [7.94] 13.0 [3.8] 33,100 [9.70] 4.6 30,600 [8.97] 18.6 [5.5] 27,700 [8.12] 4.0 29,200 [8.56] 16.0 [4.7] 20,600 [6.04] 3.1
TRM-36 HFC-410A 32,000 [9.38] 12.5 [3.7] 39,500 [11.58] 4.6 36,700 [10.76] 18.8 [5.5] 32,000 [9.38] 3.8 33,000 [9.67] 14.3 [4.2] 25,000 [7.33] 3.1
performanCe and SpeCifiCaTionS
AHRI/ISO/ASHRAE 13256-1 Data (English (IP) Units & Metric (SI) Units)
Cooling capacities based upon 80.6F [27C] DB, 66.2F [19C] WB entering air temperature.
Heating capacities based upon 68F [20C] DB, 59F [15C] WB entering air temperature.
All ratings based upon operation at the lower voltage of dual voltage rated models.
* Not including risers or anges.
** 80 [203.2cm] also standard.
Model
Overall Cabinet*
W D H **
09 - 12
in.
cm
17.0
43.2
17.0
43.2
88.0
223.5
15 - 18
in.
cm
20.0
50.8
20.0
50.8
88.0
223.5
24 - 36
in.
cm
24.0
61.0
24.0
61.0
88.0
223.5
Model Volts Hz Phase
09 - 36
208/230
265
60
60
1
1
Dimensional Data Voltage Options
30
The Tranquility Console (TRC) Series provides a
high efciency WSHP ductless solution for spaces
where individual, quiet control of the heating and
cooling system is important. Tranquility Console
Series units are especially ideal where ceiling
height and space are limited, or when preserving
the integrity of an existing structure. The Tranquility
Console Series exceeds ASHRAE 90.1 efciencies,
yet maintains small cabinet dimensions. Using
EarthPure

(HFC-410A) refrigerant, the Tranquility


Console Series not only protects the environment,
it does so while delivering unprecedented comfort,
efciency, and reliability.
uniT feaTureS
Sizes 09 (3/4 ton, 2.6 kW) through 18 (1-1/2
ton, 5.3 kW)
Environmentally-friendly EarthPure

(HFC-410A)
zero ozone depletion refrigerant
Two-piece chassis/cabinet design
Slope top with aluminum rigid bar supply air grille
and aluminum control door
TXV metering device
Extended range (20 to 120F, -6.7 to 48.9C)
operation
Advanced digital auto or manual change-over
unit mounted control with temperature display,
speed selection and fault indication
Remote-mounted control available
Microprocessor controls standard (optional DXM
and/or DDC controls)
LonWorks, BACnet, Modbus and Johnson N2
compatibility options for DDC controls
Right or left-hand piping arrangement
Front or bottom return air
Unit Performance Sentinel performance
monitoring system
Eight safeties standard
Wide variety of options including e-coated air
coils and UltraQuiet construction
TranquiliTy ConSole (TrC) SerieS
Optional motorized damper
for outside air intake for
improved air quality
Optional insulated
water circuit for extended
range applications
Advanced digital controls
with Remote Service
Sentinel. (Optional
Enhanced controls (DXM)
& DDC Controllers)
Unit mounted digital
control available in
manual and auto
changeover
Shown with optional
return air grille
31
Model Refrigerant
Water Loop Heat Pump Ground Water Heat Pump Ground Loop Heat Pump
Cooling 86F [30C] Heating 68F [20C] Cooling 59F [15C] Heating 50F [10C] Cooling 77F [25C] Heating 32F [0C]
Capacity EER Capacity
COP
Capacity EER Capacity
COP
Capacity EER Capacity
COP
Btuh
[kW]
Btuh/W
[W/W]
Btuh
[kW]
Btuh
[kW]
Btuh/W
[W/W]
Btuh
[kW]
Btuh
[kW]
Btuh/W
[W/W]
Btuh
[kW]
TRC-09 HFC-410A 8,600 [2.52] 13.3 [3.9] 11,400 [3.34] 4.6 9,200 [2.70] 18.6 [5.5] 9,500 [2.78] 4.0 8,800 [2.58] 14.9 [4.4] 7,300 [2.14] 3.3
TRC-12 HFC-410A 11,300 [3.31] 13.3 [3.9] 14,900 [4.37] 4.9 12,500 [3.66] 18.7 [5.5] 12,100 [3.55] 4.1 11,800 [3.46] 15.1 [4.4] 9,300 [2.73] 3.3
TRC-15 HFC-410A 14,100 [4.13] 13.5 [4.0] 18,200 [5.33] 5.1 16,600 [4.87] 21.3 [6.2] 14,800 [4.34] 4.3 15,100 [4.43] 15.8 [4.6] 11,400 [3.34] 3.5
TRC-18 HFC-410A 16,200 [4.57] 13.0 [3.8] 20,100 [5.89] 4.5 17,600 [5.16] 19.5 [5.7] 16,500 [4.84] 4.0 16,500 [4.84] 15.0 [4.4] 13,200 [3.87] 3.4
performanCe and SpeCifiCaTionS
AHRI/ISO/ASHRAE 13256-1 Data (English (IP) Units & Metric (SI) Units)
Cooling capacities based upon 80.6F [27C] DB, 66.2F [19C] WB entering air temperature.
Heating capacities based upon 68F [20C] DB, 59F [15C] WB entering air temperature.
All ratings based upon operation at the lower voltage of dual voltage rated models.
Dimensional Data
Model
Overall Cabinet
W D H
5
[12.7]
Subbase
in.
cm
48
121.9
12
30.5
26
66.0
No
Subbase
in.
cm
48
121.9
12
30.5
21
53.3
Model Volts Hz Phase
09-12
115
208/230
265
60
60
60
1
1
1
15-18
208/230
265
60
60
1
1
Voltage Options
Note: Add 6 [15.2cm] to width for size 18.
32 TranquiliTy CompaCT (TCH) SerieS
Available in sizes 6 tons (21.1 kW) through 10 tons
(35.2 kW) with multiple cabinet congurations,
the Tranquility Compact (TCH) Series offers a
wide range of units for most any installation. The
Tranquility Compact Series has an extended
range refrigerant circuit, capable of ground
loop (geothermal) applications (may require
optional extended range insulation), ground water
(geothermal) applications, as well as water loop
(boiler-tower) applications. Standard features are
many. Microprocessor controls, galvanized steel
cabinet, epoxy powder coat painted front access
panel, galvanized steel with epoxy powder coat
painted drain pan and TXV refrigerant metering
device are just some of the features of the exible
Tranquility Compact Series.
uniT feaTureS
Horizontal sizes 072 (6 tons, 21.1 kW), 096 (8
tons, 28.1 kW), 120 (10 tons, 35.2 kW)
Unit conguration can be ordered with left or
right return air and straight or back supply air
discharge. Discharge is eld convertible. Field
conversion uses all existing parts including panels
and belts
Electrical box is on right side and can be eld
converted to left side of unit
Electric power can enter from either side of front
Water can be connected to either side
Copeland scroll compressors
Dual refrigeration circuits (All Models)
Exceeds ASHRAE 90.1 efciencies
Galvanized steel construction with attractive matte
black epoxy powder coat painted front access
panel
Insulated divider and separate compressor/air
handler compartments
TXV metering device
Extended range (20 to 120F, -6.7 to 48.9C)
operation (may require optional extended range
insulation)
Condensate overow is
one of the 8 standard
safeties provided by the
microprocessor controls in
all TCH Series units
Dual compressor
refrigeration circuit
Large capacity (up to 10
tons)
Belt drive blower with high
efciency motor and multiple
pulley adjustments
Galvanized steel cabinet
Optional insulated water/
refrigerant circuits allow
extended range operation
(ground loop applications)
33
performanCe and SpeCifiCaTionS
AHRI/ISO/ASHRAE 13256-1 Data (English (IP) Units & Metric (SI) Units)
Cooling capacities based upon 80.6F [27.02C] DB, 66.2F [19.02C] WB entering air temperature.
Heating capacities based upon 68F [20.02C] DB, 59F [15.02C] WB entering air temperature.
All ratings based upon operation at lower voltage of dual voltage rated models.
Dimensional Data
Horizontal
Model
Overall Cabinet
W D H
072 - 120
in.
cm
36.3
92.2
84.9
215.6
21.6
54.9
Horizontal
Model
Volts Hz Phase
072 - 120
208/230
460
575
60
60
60
3
3
3
Voltage Options
Model Refrigerant
Water Loop Heat Pump Ground Water Heat Pump Ground Loop Heat Pump
Cooling 86F [30C] Heating 68F [20C] Cooling 59F [15C] Heating 50F [10C] Cooling 77F [25C] Heating 32F [0C]
Capacity EER Capacity
COP
Capacity EER Capacity
COP
Capacity EER Capacity
COP
Btuh
[kW]
Btuh/W
[W/W]
Btuh
[kW]
Btuh
[kW]
Btuh/W
[W/W]
Btuh
[kW]
Btuh
[kW]
Btuh/W
[W/W]
Btuh
[kW]
TCH-072 HFC-410A 69,000 [20.22] 13.3 [3.9] 92,500 [27.11] 5.0 78,500 [23.01] 19.7 [5.8] 75,500 [22.13] 4.4 71,000 [20.80] 14.6 [4.3] 58,000 [17.00] 3.5
TCH-096 HFC-410A 95,000 [27.84] 13.7 [4.0] 123,000 [36.04] 5.0 104,500 [30.63] 20.0 [5.9] 101,000 [29.60] 4.4 98,000 [28.72] 15.2 [4.5] 77,000 [22.57] 3.6
TCH-120 HFC-410A 119,000 [34.88] 13.3 [3.9] 160,000 [46.89] 4.6 134,000 [39.27] 19.3 [5.7] 132,500 [38.83] 4.0 122,500 [35.90] 14.5 [4.2] 103,000 [30.19] 3.3
34
The award winning Tranquility Large (TL) Series
raises the bar for water-source heat pump
efciencies, features and application exibility.
Not only does the Tranquility Large Series
exceed ASHRAE 90.1 efciencies, but it also uses
EarthPure

(HFC-410A) zero ozone depletion


refrigerant, making it an extremely environmentally-
friendly option. Tranquility Large Series is eligible
for additional LEED

(Leadership in Energy and


Environmental Design) points because of the green
technology design.
uniT feaTureS
Vertical sizes 084 (7 tons, 24.6 kW) through 300
(25 tons, 87.9 kW)
Unit conguration can be ordered with, or
converted to front or back return and top, front, or
back discharge. Field conversion uses all existing
parts including panels and belts
Electrical box can be eld converted to be on
front or back of unit
Electric power can enter from any side of unit
Water and drain can be connected to either side
Dual refrigeration circuits (TL168, 192, 240, 300)
Exceeds ASHRAE 90.1 efciencies
TXV metering device
Extended range (20 to 120F, -6.7 to 48.9C
operation)
Microprocessor controls standard (optional DXM
and/or DDC controls)
LonWorks, BACnet, Modbus and Johnson N2
compatibility options for DDC controls
Unit Performance Sentinel performance
monitoring system
TranquiliTy large (Tl) SerieS
Condensate overow is
one of the 8 standard
safeties provided by the
microprocessor controls in all
TL Series units
Dual compressor refrigeration circuit in TL 168-300
equipment single compressor refrigeration circuit in
TL 084-150
Optional insulated water/
refrigerant circuits allow
extended range operation
(ground loop applications)
Belt drive blowers with
high efciency motors and
multiple pulley adjustments
Wide variety of vertical
congurations
Large capacity (up to 25
tons, 87.97 kW)
Galvanized steel cabinet
with baked-on epoxy powder
nish on all access panels
35
performanCe and SpeCifiCaTionS
AHRI/ISO/ASHRAE 13256-1 Data (Engish (IP) Units & Metric (SI) Units)
Cooling capacities based upon 80.6F [27C] DB, 66.2F [19C] WB entering air temperature.
Heating capacities based upon 68F [20C] DB, 59F [15C] WB entering air temperature.
All ratings based upon operation at the lower voltage of dual voltage rated models.
Dimensional Data
Vertical
Model
Overall Cabinet
W D H
084
-150
in.
cm
53.1
134.9
34.0
86.4
79.0
200.7
168
-300
in.
cm
106.7
270.9
34.0
86.4
79.0
200.7
Vertical
Model
Volts Hz Phase
084 - 300
208/230
460
575
380/420
60
60
60
60
3
3
3
3
Voltage Options
Model Refrigerant
Water Loop Heat Pump Ground Water Heat Pump Ground Loop Heat Pump
Cooling 86F [30C] Heating 68F [20C] Cooling 59F [15C] Heating 50F [10C] Cooling 77F [25C] Heating 32F [0C]
Capacity EER Capacity
COP
Capacity EER Capacity
COP
Capacity EER Capacity
COP
Btuh
[kW]
Btuh/W
[W/W]
Btuh
[kW]
Btuh
[kW]
Btuh/W
[W/W]
Btuh
[kW]
Btuh
[kW]
Btuh/W
[W/W]
Btuh
[kW]
TLV-084 HFC-410A 82,000 [24.03] 15.2 [4.5] 101,000 [29.60] 4.8 87,500 [25.65] 21.0 [4.3] 83,500 [24.33] 4.3 83,000 [24.33] 16.5 [4.8] 65,500 [19.20] 3.6
TLV-096 HFC-410A 94,000 [27.55] 15.0 [4.4] 118,000 [34.58] 4.7 102,500 [30.04] 20.5 [4.2] 96,500 [28.58] 4.2 97,500 [28.58] 16.5 [4.8] 76,500 [22.42] 3.6
TLV-120 HFC-410A 118,000 [34.58] 15.0 [4.4] 144,000 [42.20] 5.0 133,000 [38.98] 21.0 [4.2] 118,000 [34.58] 4.2 120,000 [35.17] 16.5 [4.8] 93,000 [27.26] 3.7
TLV-150 HFC-410A 150,000 [43.96] 14.0 [4.1] 186,000 [54.51] 4.7 170,000 [49.82] 20.0 [4.2] 155,000 [45.43] 4.2 156,000 [45.72] 15.8 [4.6] 122,000 [35.76] 3.6
TLV-168 HFC-410A 166,000 [48.65] 15.5 [4.5] 204,020 [59.80] 4.9 177,000 [51.87] 21.4 [4.4] 169,000 [49.53] 4.4 168,000 [49.24] 16.8 [4.9] 132,500 [38.83] 3.7
TLV-192 HFC-410A 190,000 [55.69] 15.3 [4.5] 238,360 [69.86] 4.8 207,000 [60.67] 20.9 [4.3] 195,000 [57.15] 4.3 197,000 [57.74] 16.8 [4.9] 155,000 [45.43] 3.7
TLV-240 HFC-410A 238,500 [69.90] 15.3 [4.5] 291,000 [85.29] 5.1 269,000 [78.84] 21.4 [4.3] 238,000 [69.90] 4.3 242,500 [71.07] 16.8 [4.9] 188,000 [55.10] 3.8
TLV-300 HFC-410A 300,000 [87.93] 14.0 [4.1] 372,000 [109.03] 4.7 340,000 [99.65] 20.0 [4.2] 310,000 [90.86] 4.2 312,000 [91.44] 15.8 [4.6] 244,000 [71.51] 3.6
36
The Tranquility Modular Water-to-Water (TMW)
Series offers high efciency and high capacity with
advanced features, quiet operation and application
exibility at competitive prices. ClimateMasters
Tranquility Modular Water-to-Water Series can be
used for radiant oor heating, snow/ice melt, chilled
water for fan coils, industrial process control, potable
hot water generation*, hot/chilled water for make-
up air, and many other types of HVAC and industrial
applications that require cost effective heated or
chilled water.
uniT feaTureS
Sizes 036 (3 tons, 10.6 kW) through 340
(28 tons, 100 kW)
Copeland scroll compressor(s)
Dual independent refrigeration circuits on size
120 and 340 (28 tons, 100 kW)
Exclusive single side service access (front of unit)
allows multiple units to be installed side-by-side for
large capacity installations
Top water connections on sizes 170 (14 tons, 50
kW) and 340 (28 tons, 100 kW), staggered for
ease of manifolding multiple units
Exceeds ASHRAE 90.1 efciencies
Heavy gauge galvanized steel construction with
polyester powder coat paint and stainless steel
front access panels
Insulated compressor compartment
Small footprint
TXV metering devices
Extended range (20 to 110F, -6.7 to 43.3C)
operation
Microprocessor controls standard (optional DXM
and/or DDC controls)
LonWorks, BACnet, Modbus and Johnson N2
compatibility options for DDC controls
* Requires field supplied secondary heat exchanger.
TranquiliTy modular waTer-To-waTer (Tmw) SerieS
Copeland scroll compressors
with dual-isolation mounting
for quiet operation
Advanced digital controls
with Remote Service
Sentinel and compressor
run and fault LED
TMW Series design allows for
single side service access.
Units may be installed side-by-side
Extended range insulated
water/refrigerant circuit standard
Optional Enhanced controls
(DXM) & DDC Controllers
Small footprint with
convenient front service
access (TMW036 shown)
37
performanCe and SpeCifiCaTionS
AHRI/ISO/ASHRAE 13256-2 Data (English (IP) Units*)
Dimensional Data
Model
Overall Cabinet
W D H
036-060
in.
cm
25.4
645
30.6
778
33.0
83.8
120
in.
cm
52.9
134.4
30.6
778
37.0
940
170-340
in.
cm
26.3
669
45.1
1146
64.5
163.8
All ratings based upon operation at the lower voltage of dual voltage rated models.
* Indoor = Load side heat exchanger; Outdoor = Source side heat exchanger.
Model Volts Phase
036
208/230
265
208/230
460
575
1
1
3
3
3
060-120
208/230
208/230
460
575
1
3
3
3
170-340
208/230
460
575
3
3
3
Voltage Options
Model Refrigerant
Water Loop Heat Pump Ground Water Heat Pump Ground Loop Heat Pump
Cooling Heating Cooling Heating Cooling Heating
Indoor 53.6F
Outdoor 86F
Indoor 104F
Outdoor 68F
Indoor 53.6F
Outdoor 59F
Indoor 104F
Outdoor 50F
Indoor 53.6F
Outdoor 77F
Indoor 104F
Outdoor 32F
Capacity
Btuh
EER
Btuh/W
Capacity
Btuh
COP
Capacity
Btuh
EER
Btuh/W
Capacity
Btuh
COP
Capacity
Btuh
EER
Btuh/W
Capacity
Btuh
COP
TMW-036 HFC-410A 33,000 14.6 44,000 5.0 37,000 23.1 36,000 4.0 34,000 16.8 28,000 3.1
TMW-060 HFC-410A 55,400 14.1 79,000 4.7 62,600 21.7 61,400 3.8 58,000 15.4 51,000 3.0
TMW-120 HFC-410A 110,800 13.8 158,000 4.6 125,200 21.3 122,900 3.7 116,000 15.1 102,000 3.0
TMW-170 HFC-410A 126,000 13.6 168,000 4.4 141,200 19.7 139,000 3.8 133,000 15.6 110,800 3.0
TMW-340 HFC-410A 253,500 13.6 336,200 4.4 282,000 19.6 277,000 3.7 266,600 15.6 220,000 3.0
Model Refrigerant
Water Loop Heat Pump Ground Water Heat Pump Ground Loop Heat Pump
Cooling Heating Cooling Heating Cooling Heating
Indoor 12C
Outdoor 30C
Indoor 40C
Outdoor 20C
Indoor 12C
Outdoor 15C
Indoor 40C
Outdoor 10C
Indoor 12C
Outdoor 25C
Indoor 40C
Outdoor 0C
Capacity
Watts
EER
W/W
Capacity
Watts
COP
Capacity
Watts
EER
W/W
Capacity
Watts
COP
Capacity
Watts
EER
W/W
Capacity
Watts
COP
TMW-036 HFC-410A 9,672 4.3 12,896 5.00 10,844 6.77 10,551 4.00 9,965 4.92 8,206 3.10
TMW-060 HFC-410A 16,237 4.13 23,154 4.70 18,347 6.36 17,995 3.8 16,999 4.51 14,947 3.00
TMW-120 HFC-410A 32,474 4.0 13,572 4.60 36,694 6.24 36,020 3.74 33,998 4.42 29,895 3.00
TMW-170 HFC-410A 37,163 4.0 49,414 4.40 41,383 5.77 40,739 3.80 38,980 4.57 32,474 3.00
TMW-340 HFC-410A 74,297 4.0 98,535 4.40 82,649 5.74 81,184 3.70 78,136 4.57 64,478 3.00
TMW 036 - 340 Performance Data ASHRAE/AHRI/ISO 13256-2 60Hz Metric (SI) Units
38
The Rooftop (TRE) Series provides an economical
solution for todays HVAC challenges. The TRE
product line offers the option of introducing a xed
amount of outside air year-round or a modulating
Economizer to provide free cooling when outdoor
conditions are favorable. TRE units are designed for
an extended range of source water temperatures,
making it suitable for closed-loop, or ground source
closed-loop systems. With high efciency scroll
compressors and belt drive motors, the TRE product
line offers 13+ EER and 4+ COP.
uniT feaTureS
Sizes 036 (3 tons, 10.6 kW) through 240 (20 tons,
70.4 kW)
EarthPure

(HFC-410A) zero ozone depletion


refrigerant
Exceeds ASHRAE 90.1 efciencies (40% better
than standard rooftop units!)
Galvanized steel construction and powder coat
paint on all units
Copeland Scroll compressors (dual circuited on
sizes 096 and larger)
Microprocessor controls standard (optional DXM
and/or DDC controls)
Bi-directional, balanced port expansion valve
refrigerant metering device standard
Extended range operation package standard
Double wall construction for access doors and
stainless steel hardware
Belt-drive blowers with various congurations for
RPM/ESP settings
High/low pressure switches and electronic
condensate overow sensor standard
Eight safeties standard
Rx ERV option handles up to 100% outside air
THe roofTop (Tre) SerieS
Slide out blower assembly
featuring high efciency
motors/variable pitch
sheaves
ABS gear driven dampers
Integrated lifting lugs
Heavy duty cabinet,
powder coated, stainless
steel hinges
Copeland Scroll compressors
(dual circuited on 8 ton
and larger)
Fully insulated including
base pan
2 berglass lters
standard. Optional 4 and
pleated lters (pleated
lters shown)
TRE with Enthalpy Economizer
option shown.
39
Model Refrigerant
Water Loop Heat Pump Ground Water Heat Pump Ground Loop Heat Pump
Cooling 86F [30C] Heating 68F [20C] Cooling 59F [15C] Heating 50F [10C] Cooling 77F [25C] Heating 32F [0C]
Capacity EER Capacity
COP
Capacity EER Capacity
COP
Capacity EER COP
COP
Btuh
[kW]
Btuh/W
[W/W]
Btuh
[kW]
Btuh
[kW]
Btuh/W
[W/W]
Btuh
[kW]
Btuh
[kW]
Btuh/W
[W/W]
Btuh
[kW]
TRE-036 HFC-410A 36,000 [10.56] 14.5 [4.2] 44,000 [12.90] 5.1 41,000 [12.02] 22.1 [6.5] 36,500 [10.70] 4.5 36,000 [10.56] 16.8 [4.9] 29,000 [8.50] 3.7
TRE-048 HFC-410A 50,000 [14.65] 14.7 [4.3] 61,500 [18.02] 4.8 56,500 [16.56] 21.5 [6.3] 50,000 [14.65] 4.2 51,500 [15.09] 16.3 [4.8] 39,000 [11.43] 3.5
TRE-060 HFC-410A 63,000 [18.46] 16.0 [4.7] 75,000 [22.00] 5.2 72,000 [21.10] 24.0 [7.0] 62,000 [18.17] 4.6 64,000 [18.76] 18.0 [5.3] 47,000 [13.77] 3.7
TRE-072 HFC-410A 69,000 [20.22] 15.2 [4.5] 90,000 [26.38] 5.2 77,500 [22.71] 21.6 [6.3] 74,000 [21.69] 4.6 71,000 [20.81] 16.4 [4.8] 58,000 [17.00] 3.7
TRE-096 HFC-410A 100,000 [29.31] 14.3 [4.2] 114,000 [33.41] 4.5 111,950 [32.81] 21.0 [6.2] 94,500 [27.70] 4.0 104,000 [30.48] 15.9 [4.7] 76,200 [22.33] 3.3
TRE-120 HFC-410A 126,000 [36.93] 1 4.2 [4.2] 154,000 [45.13] 4.5 145,500 [42.64] 21.0 [6.2] 126,500 [37.07] 4.0 132,500 [38.83] 15.9 [4.7] 101,000 [29.60] 3.3
TRE-144 HFC-410A 134,000 [39.27] 13.8 [4.0] 172,000 [50.41] 4.6 150,500 [44.11] 20.0 [5.9] 140,000 [41.03] 4.0 139,000 [40.74] 15.5 [4.5] 109,000 [31.94] 3.3
TRE-168 HFC-410A 175,000 [51.29] 15.0 [4.4] 206,700 [60.58] 5.0 187,000 [54.80] 20.9 [6.1] 168,000 [49.24] 4.5 177,500 [52.02] 16.5 [4.8] 129,500 [37.95] 3.7
TRE-240 HFC-410A 241,000 [70.63] 13.6 [4.0] 287,000 [84.11] 4.8 276,000 [80.89] 19.3 [5.7] 230,000 [67.41] 4.2 249,500 [73.12] 15.0 [4.4] 182,400 [53.46] 3.4
AHRI/ISO/ASHRAE 13256-1 Data (English (IP) Units & Metric (SI) Units)*
Cooling capacities based upon 80.6F DB, 66.2F WB entering air temperature.
Heating capacities based upon 68F DB, 59F WB entering air temperature.
All ratings based upon operation at lower voltage of dual voltage rated models
* Does not include optional rain hood.
Dimensional Data
Model
Overall Cabinet
W D* H
03 - 07
in.
cm
43.2
109.7
80.1
203.5
39.4
100.1
08 - 12
in.
cm
49.2
125.0
90.1
228.9
45.4
115.3
15 - 20
in.
cm
87.1
221.2
90.1
228.9
50.6
128.5
performanCe and SpeCifiCaTionS
Model Volts Hz Phase
03
208/230
460
60
60
3
3
04 - 20
208/230
460
575
60
60
60
3
3
3
Voltage Options
40
The energy recovery wheel inside the ERV unit
transfers energy from the warmer to the cooler air
stream through counter-owing supply and exhaust
air streams through the slowly rotating wheel (less
than 60 revolutions per minute). The large energy
transfer surface arranged to provide laminar air
ow through the wheel causes the constant ow
of recovered energy to represent up to 80% of the
difference in total energy contained within the two
air streams. The Rx (ERV) Series is designed to be
mated to the TRE Series rooftop unit for maximum
energy efciency in a make-up air unit, up to 100%
outside air.
uniT feaTureS
Sizes 1,000 through 10,000 CFM of outdoor air
mixed with return air or up to 100% outside air
All of the features of the TRE Series PLUS energy
recovery
20+ (Combined) EER substantially reduces the
cost of preconditioning outside air
Avoids using large gas makeup air units and
complicated refrigeration controls to handle
outside air
Simple operation facilitates ease of maintenance
and troubleshooting
Allows the designer to provide water-source
equipment for all HVAC needs
Decreases building equipment tonnage required,
which reduces installation costs
Can cut loop costs up to 50% for ground
loop (geothermal) applications by reducing
equipment tonnage required
Uses ARI-1060 rated wheel technology
Available with silica gel or molecular sieve wheel
Available in stand alone, curb mounted
& integrated, or mounted to rooftop unit
congurations
Finish matches TRE Series rooftop
Optional factory-installed pre-heater available
Hinged panels at all service entries
Centrifugal belt-driven forward-curved blowers
with adjustable pulleys and isolation pads. High
efciency motors are thermally protected
Easy access controls with optional ERV
fault indicators. Six-pin Molex connector ties ERV
controls to TRE Series rooftop unit controls
2 pleated pre-lters for outside air with 2
pleated lters on exhaust air help keep the wheel
clean. Up to Merv 13 lter compatible
Heavy duty base rails for easy lifting and rigging
Hinged access doors with 1/4 turn spring-
loaded latches
Exhaust and supply air streams have back-draft
dampers to prevent air penetration during
off cycles
The energy recovery wheel transfers energy from
the warmer to cooler air streams at a nominal up
to 80% efciency and is ARI-1060 certied
Slide out wheel assembly makes cleaning and
maintenance easy
THe rx (erV) module
Stand alone ERV
module
Add on module for
TRE unit
41
performanCe and SpeCifiCaTionS
Air Flow Range, Voltages, and Pre-Heaters (English (IP) Units & Metric (SI) Units)
Dimensional Data, Stand Alone ERV Module
ERV
Cabinet
Overall Cabinet
Height in.
[CM]
Width in.
[CM]
Length in.
[CM]
Weight lb.
[CM]
ERV A
Cabinet
50
[127]
46
[116.8]
66
[167.64]
1472
[667.7]
ERV B
Cabinet
65
[165.1]
68
[172.7]
78
[198.1]
2409
[1092.7]
ERV C
Cabinet
77
[195.5]
94
[238.8]
94
[238.8]
3452
[1565.8]
ERV D
Cabinet
89
[226.0]
108
[274.3]
106
[269.2]
4924
[2233.5]
Model Voltage CFM
ERV A Cabinet
208/230/460
60 Hz
1000 - 2000
ERV B Cabinet 3000 - 4000
ERV C Cabinet 5000 - 7000
ERV D Cabinet 8000 - 10000
Energy recovery component certied to ARI standard 1060-2000.
Energy recovery unit ETL listed.
Contact factory for performance at given conditions.
42
100% ouTdoor air
appliCaTionS - VerTiCal doaS
SySTemS
ClimateMaster Dedicated Outdoor Air Systems
(TO) Series provides the most complete solution for
your water-source application. Our many options
and congurations allow the design for outdoor
air requirements to be incorporated into the water
loop system, further enhancing the advantages of a
WSHP application. The ability to precisely control
leaving air dew point temperature in summer, handle
extremely cold entering air temperatures in winter,
and perform at part load conditions give designers
unmatched exibility in building design, Indoor Air
Quality (IAQ) and energy efciency.
uniT feaTureS
Leaving Air Temperature Control
Supply air temperature controlled to 0.2F
(0.1C)
Substantial energy savings and ASHRAE
90.1 compliant
Conditioned outdoor air can be introduced
directly into space
Evaporator Coil
Raised lance ns, ried tubes maximize
moisture removal
Drain Pan
Stainless steel pan minimizes corrosion
Sloped design avoids hazardous puddling
Fans
Forward curved centrifugal blowers or
plenum fans
Refrigerant Reheat Coil
Sized for neutral LAT (65 to 80F, 18 to 27C)
with 0.2F (0.1C) control
Adequate coil separation avoids re-hydration
Scroll Compressor
State-of-the-art compressor technology for highest
efciency and reliability
Quiet operation
Units 8 tons (28kW) and larger, multiple
compressors are staged to match the load
Electrical Service
Single point connection, including heat all units
Cabinet Construction
Single wall construction for sizes up to 15 tons
Double-wall construction standard on 20, 25 and
30 ton (70, 88 and 105 kW) units
Corrosion-resistant galvanized construction
All serviceable elements accessible from rear and
LH side of unit
Insulation
Closed cell foam or polystyrene board in double-
wall construction
Superior to berglass insulation eliminates ber-
release into air
Meets ASTM mold, mildew, moisture
resistance specications
Refrigeration Circuit
Dissipates captured heat into water loop
Unique design - no reversing valve
Modulating hot gas reheat
Filters
4 deep extended surface, pre-lters (MERV 7)
Additional Options Increase Flexibility
Optional coil coatings available for
corrosive environments
Single phase available on 4 and 5 ton (14 and
18 kW) units
Optional power disconnects (fused and non-fused)
Units available in 4 - 30 tons (14 to 105 kW)
Contact factory for non-standard options
dediCaTed ouTdoor air SySTemS (To) SerieS
43
Refrigerant Circuit Schematic with LAT Control: Cooling Mode
COMPRESSOR
RECEIVER
C
O
I
L
90F
WATER IN
100F
WATER OUT
55F 12.8C LAPD
EEV
W
A
T
E
R
WARM
HUMID AIR
95F 35 C DB@
78 F 26C WB
WARM
HUMID AIR
75F 24 C DB
50% RH
HOT GAS
REHEAT
WATER
CONDENSER
COOLING
EVAPORATOR
HEATING
EVAPORATOR
(INACTIVE)
100F
WATER IN
AIR
COI
38C
38C 38C
32C
L
C
O
I
L
W
A
T
E
R
100F
WATER OUT
COLD
WINTER
AIR
(PART LOAD)
COMPRESSOR
RECEIVER
C
O
I
L
60
F 18C
F 15.6C
WATER IN WATER OUT
EEV
W
A
T
E
R
EXACT LAT
75 F DB
24C DB
HOT GAS
REHEAT
WATER
CONDENSER
COOLING
EVAPORATOR
(INACTIVE)
HEATING
EVAPORATOR
C
O
I
L
W
A
T
E
R
WATER IN
65 F 18C 65
F 14C 57
WATER OUT
AIR
COIL
40F 4.4C EAT
Refrigerant Circuit Schematic with LAT Control: Heating Mode
Model
Overall Cabinet
W D H
04 - 05
in.
cm
34.0
86.4
38.9
98.8
60.1
152.7
08 - 15
in.
cm
41.9
106.4
46.0
116.8
80.1
203.5
20 - 30
in.
cm
77.3
196.3
61.5
156.2
70.0
177.8
Dimensional Data
44
100% ouTdoor air
appliCaTionS - HorizonTal
doaS SySTemS
ClimateMaster Dedicated Outdoor Air Systems
(TO) Series provides the most complete solution for
your water-source application. Our many options
and congurations allow the design for outdoor
air requirements to be incorporated into the water
loop system, further enhancing the advantages of a
WSHP application. The ability to precisely control
leaving air dew point temperature in summer, handle
extremely cold entering air temperatures in winter,
and perform at part load conditions give designers
unmatched exibility in building design, Indoor Air
Quality (IAQ) and energy efciency.
uniT feaTureS
Precise Leaving Air Temperature Control
Air temperature leaving dehumidier controlled to
0.2F (0.1C)
Substantial energy savings
Conditioned outdoor air can be introduced
directly into space
Evaporator Coil
Raised lance ns, ried tubes maximize
moisture removal
Very high MREs (Moisture Removal Efciency)
Drain Pan
Stainless steel pan minimizes corrosion
Refrigerant Reheat Coil
Sized for neutral LAT (65 to 80F, 18 to 27C)
Air separation avoids condensate re-vaporization
Scroll Compressor
State-of-the-art compressor technology for highest
efciency and reliability
Quietest operation for less noise
Over 5 tons (18 kW), multiple compressors are
staged to match the load
Fans
Forward curved centrifugal blowers
Backward-inclined centrifugal fans, plug fans on
larger units
Electrical Service
Single point power connection, for all units
Controls
Simple ladder logic addresses wide variety
of conditions
System can handle dehumidication, cooling,
and heating
Occupancy contact ensures outdoor air enters
only when needed
Cabinet Construction
Corrosion-resistant galvanneal with powder
coat nish
Meets 1000 hour salt spray test
All serviceable elements accessible from one side
of unit
Double-wall construction
R-5 insulation
Refrigeration Circuit
Dissipates captured heat into water loop
Unique design - no reversing valve
Modulating hot gas reheat
Filters
4 deep extended surface pre-lters (MERV 7)
Outdoor Design (Rooftop Models)
Rain hood, aluminum mist eliminator
Stainless steel fasteners
Isolation dampers
TEFC motors
Rx Energy Recovery Wheel (Optional)
Sensible and latent heat recovery
Signicant energy savings by lowering
operating costs
Additional Options Increase Flexibility
Top, bottom or end horizontal air discharge
Horizontal or Rooftop congurations available
Optional coil coatings available for
corrosive environments
Optional power disconnects (fused and non-fused)
Contact factory for non-standard options
dediCaTed ouTdoor air SySTemS (To) SerieS
45
(Optional) Energy Recovery Wheel Operation
O/A
20
16
50% RH
Off Wheel
66F 19C DB@ F 24C DB@
F 9C WB F 13C WB
F -7C DB@
F -9C WB
F -2C DB
F 24C DB@
F 24C DB@
56
E/A
1000 CFM
28
94% RH
S/A
1000 CFM
75
49F 9C Dewpoint
52% RH
R/A
75
50% RH
Evap. Coil
(Inactive)
Reheat Coil
(Inactive)
Aux.
Heating
WINTER
Energy Recovery Wheel
85% Sensible Efficiency
78% Latent Efficiency
82% Overall
O/A
88
79
68% RH
Off Wheel
77
67
E/A
1000 CFM
86F 30C DB
F 31C DB@
F 25C DB@
F 26C WB
F 19C WB
F 12C DB@ F, 24C DB@
F 12C WB
64% RH
S/A
1000 CFM
75F 24C DB@
54F 12C Dewpoint
50% RH
R/A
78F 26C DB
55% RH
Evap. Coil
Aux. Heating
(Inactive)
Reheat
Coil
SUMMER
Energy Recovery Wheel
85% Sensible Efficiency
78% Latent Efficiency
80% Overall
Off Evap.
54
53
Off Reheat
75
54F 12C Dewpoint
Off Aux Heat
75
49
O/A
20
16
50% RH
Off Wheel
66F 19C DB@ F 24C DB@
F 9C WB F 13C WB
F -7C DB@
F -9C WB
F -2C DB
F 24C DB@
F 24C DB@
56
E/A
1000 CFM
28
94% RH
S/A
1000 CFM
75
49F 9C Dewpoint
52% RH
R/A
75
50% RH
Evap. Coil
(Inactive)
Reheat Coil
(Inactive)
Aux.
Heating
WINTER
Energy Recovery Wheel
85% Sensible Efficiency
78% Latent Efficiency
82% Overall
O/A
88
79
68% RH
Off Wheel
77
67
E/A
1000 CFM
86F 30C DB
F 31C DB@
F 25C DB@
F 26C WB
F 19C WB
F 12C DB@ F, 24C DB@
F 12C WB
64% RH
S/A
1000 CFM
75F 24C DB@
54F 12C Dewpoint
50% RH
R/A
78F 26C DB
55% RH
Evap. Coil
Aux. Heating
(Inactive)
Reheat
Coil
SUMMER
Energy Recovery Wheel
85% Sensible Efficiency
78% Latent Efficiency
80% Overall
Off Evap.
54
53
Off Reheat
75
54F 12C Dewpoint
Off Aux Heat
75
49
Dimensional Data - Without Wheel
Model
Overall Cabinet
W D H
02 - 05
in.
cm
43.1
109.5
102.3
259.8
43.9
111.5
08 - 15
in.
cm
55.1
149.0
129.6
329.2
48.6
123.4
20
in.
cm
60.5
153.7
138.1
350.8
52.6
133.6
25 - 30
in.
cm
67.1
170.4
144.7
367.5
63.1
160.3
36 - 46
in.
cm
78.8
200.2
153.1
388.9
75.4
191.5
50 - 60
in.
cm
93.5
237.5
165.2
419.6
83.6
212.3
Dimensional Data - With Wheel
Model
Overall Cabinet
W D H
02 - 03
in.
cm
55.1
140.0
123.8
314.5
48.6
123.4
05
in.
cm
60.5
153.7
130.3
331.0
52.6
133.6
08
in.
cm
67.1
170.4
137.8
350.0
63.1
160.3
10
in.
cm
78.5
199.4
140.8
357.6
73.4
186.4
15
in.
cm
93.5
237.5
153.7
390.4
83.6
212.3
20 - 25
in.
cm
96.5
245.1
164.2
417.1
92.6
235.2
THe rigHT CHoiCe
ClimateMaster is the worlds largest and most
progressive manufacturer of geothermal heat
pumps. We are committed to innovation and
dedicated to environmentally clean, economically
sound and superbly comfortable home and
business environments. Each ClimateMaster
product is produced in our state-of-the-art facility
utilizing quality management systems that are ISO
9001:2000 certied. We strive for the highest
product quality and service after the sale to give
you peace of mind.
An LSB Industries, Inc. company (NYSE: LXU), ClimateMaster has been designing and building equipment that enhances environments we live and work in every day
for more than 50 years. In addition to geothermal heat pumps, ClimateMaster offers the most extensive product line of water-source heat pumps for use in a wide
variety of applications.
ClimateMaster products are built in the U.S.A.
ClimateMaster works to continually improve its products. As a result, the design and specifications of each product at the time for order may be changed without notice and may not be as described herein.
Please contact ClimateMasters Customer Service Department at 1-405-745-6000 for specific information on the current design and specifications. Statements and other information contained herein are not
express warranties and do not form the basis of any bargain between the parties, but are merely ClimateMasters opinion or recommendation of its products.
The management system governing the manufacture of ClimateMasters products is ISO 9001:2000 certied.