CVMk2 enables you to carry out the energy management and monitoring of the electrical parameters, sub-metering, and cost allocation. High technology integrated in the CVMk2, offers excellent accuracy. With the 0. And 0. Class models, you can measure power, energy, demand, etc. With full guarantees under the most demanding conditions.
CVMk2 enables you to carry out the energy management and monitoring of the electrical parameters, sub-metering, and cost allocation. High technology integrated in the CVMk2, offers excellent accuracy. With the 0. And 0. Class models, you can measure power, energy, demand, etc. With full guarantees under the most demanding conditions.
CVMk2 enables you to carry out the energy management and monitoring of the electrical parameters, sub-metering, and cost allocation. High technology integrated in the CVMk2, offers excellent accuracy. With the 0. And 0. Class models, you can measure power, energy, demand, etc. With full guarantees under the most demanding conditions.
CVMk2 APPLICATION NOTE Three-phase power and power quality analyzer Power and Precision within your reach Being able to measure and control the energy consumption and quality is becoming more and more necessary and important in any system. The CVMk2 enables you to carry out the energy management and monitoring of the electrical parameters, sub-metering, and cost allocation. The CVMk2 is a system and quality of supply analyser that measures any of the systems electrical parameters that you may require. Applications Metering La alta tecnologa integrada en el CVMk2, le proporciona The high technology integrated in the CVMk2 offers excellent accuracy. With the 0.2 and 0.5 class models, you can measure power, energy, demand, etc. with full guarantees under the most demanding conditions. Supply Quality Analysis The voltage and intensity decomposition up to 50 harmonics, ficker measurement or voltage disturbances (sags, swells, peaks), are some of the quality parameters analysed by the CVMk2, helping you to reduce energy costs and improve energy effciency in your system. Cost Allocation and Billing The CVMk2 enables you to calculate the energy consumed in the different areas/departments of your system. In addition, the CVMk2 has total, monthly and annual energy meters to make your work easier. You can complement the CVMk2 with the automatic option given in the PowerStudio software. The CVMk2 can centralise via digital pulses other energy meters or other equipment such as water or gas meters, or units produced Control of the Demand and the Power Factor Avoid penalisations due to excess demand or recharging when the power factor far from 1. The CVMk2 measures the demand (kVA, kW, I) and its maximum values, as well as the Power Factor or the cos j. A relay alarm can be assigned to perform a more exhaustive control. Transformer Study Determine whether your transformer is working effciently, with the CVMk2 you will be able to observe the harmonics and calculate the k factor. Integration of Process Signals With the different expansion cards available on the CVMk2, you will be able to measure, control and monitor the different process signals that may be produced in a system. Calculate all your consumptions: energy, water, gas meters Preventive Maintenance Establish alarms for the different parameters measured to warn you before any incident can occur. CVMk2 Three-phase power and power quality analyzer 2 CVMk2 APPLICATION NOTE Three-phase power and power quality analyzer 4-Quadrants Meter It takes measurements whilst active, reactive, both inductive and reactive, and for most parameters, such as: kWh, imported, exported kvarh imported kVAh total kVAh imported, exported Demand The CVMk2 enables you to calculate the demand using fx, sliding and thermal window. Maximum demand registers can be reset manually (password protected) from the front panel or via communications. kW demanded and maximum kVA demanded and maximum Amps per phase and three-phase demanded and maximum Communications RS-485 Port for communications with other equipment such as PLC or PC RS-485 Port to communicate with other measuring modules (up to 31 devices) Ethernet Port optional Modbus RTU, Modbus TCP Internal Memory Maximums and minimums of the values measured with date and time Split-second power failures, peaks and interruptions Energy meters Time of use confguration Alarm Confgurations Establish an alarm for any parameter measured Confgure logical functions for different outputs and with different alarms Establish an alarm for a input state Outputs and Inputs Expansion cards with 8 digital inputs for status control and meter function, and 8 digital outputs Expansion cards with 4 digital relay outputs, for control functions Expansion cards with analogical outputs and inputs to perform and measure process signals Display The display enables you to view the data and set the equipment: Large LCD with backlighting Adjustable contrast A display can show measurements of up to 32 different measuring devices. The display automatically detects any measuring module inserted in the RS-485 network Characteristics Measurements Energy: total, monthly and annual for both energy consumed and generated Demand: Fixed, sliding and thermal window Harmonics: individual and total harmonic distortion (THD in U and I). Decomposition up to 50 th harmonic Metering The CVMk2 enables energy metering in 4 quadrants for redundant meter applications, and allows you to substitute in just one device, equipment such as taximeters, network analysers CVMk2 Three-phase power and power quality analyzer 3 CVMk2 APPLICATION NOTE Three-phase power and power quality analyzer Instants The CVMk2 measures and calculates a wide range of values, such as: Voltage and intensity kW, kvar and kVA Power Factor, cos phi Frequency Imbalance between voltage and intensity and many more Billing The CVMk2 incorporates all the characteristics required to implement a billing system, among others: 1 year programmable calendar Up to 12 different time profles Working days, public holidays etc Discrimination by rates of the demand and energy accumulators Harmonics Harmonics are disturbances that introduce losses in transformers and other devices. It is essential to be able to assess them precisely, with the CVMk2 you will be able: To evaluate the THD in voltage and current To individually evaluate each harmonic up to 50 th , also in voltage and intensity To calculate the transformers Factor-K according to ANSI C57110 Universal Metering Con las tarjetas de expansin de CVMk2, puede medir With the CVMk2s expansion cards you can measure other metering devices and process signals. Pulses from gas, water, steam meters, for example. Register A non-volatile memory ensures the integrity of all the data saved. The CVMk2 registers events, energy, measurements Load Curve Together with an expansion card with SD memory, the CVMk2 incorporates the register option. The capacity of the SD cards ensures a registering period of more than 10 years. You can confgure the registering period (standard 10 minutes). You can confgure the values registered from a list of more than 500 parameters Neutral Current The CVMk2 has 4 current inputs which enables it to measure the neutral current as well. In 4-wire systems, it also allows the possibility of calculating the neutral current when there is no transformer present. Max/Min Register As the CVMk2 detects maximums and minimums, it will register them in its internal memory; together with the date and time they are produced. It registers the following, among others: Min/max voltage and current Min/max kW, kvar, and kVA Min/max power factor cos phi Min/max frequency Min/max imbalance in voltage, Factor-K
Min/Max Registering The min/max values from each period are registered in the fle. CVMk2 Three-phase power and power quality analyzer 4 CVMk2 APPLICATION NOTE Three-phase power and power quality analyzer Power Failures and other Voltage Disturbances The equipment detects and stores any disturbances from a minimum of 10 ms. Alarms Up to 10 alarms can be defned in the equipment, and, in turn, these can be associated to any output using logical functions (OR / AND). PowerStudio SCADA The PowerStudio SCADA software has a driver integrated to communicate with the CVMk2. The PowerStudio registers and displays in real-time and offers control and confguration options. http://powerstudio.circutor.com Communications All CVMk2 models contain one RS-485 port used for PC communications, and another RS-485 port used by the display, which enables it to communicate with other measuring modules. The communications ports have the following characteristics: Optically insulated Confgurable speed Compatible and ready to use with PowerStudio software Standard protocol Modbus RTU Ethernet Port (with Expansion Card) It can use a 10/100Base-Tx port for direct access to the information via Ethernet LAN/WAN Protocol: Modbus TCP Speed: 10/100 Mbps Assembly The measuring module with the display can be integrated in the DIN 144 mm x 144 mm, 92 mm x 92 mm (3.6 inches x 3.6 inches) standard. The measuring modules can be installed without display on a DIN rail. The display can be installed at a distance of 1200 m from the measuring module, and it is integrated in the panel. Approximate weight: 0.750 kg CVMk2 Three-phase power and power quality analyzer 5 CVMk2 APPLICATION NOTE Three-phase power and power quality analyzer Voltage inputs Measurement range from 5 to 120% of U n for U n = 300 V ac (ph-N) from 5 to 120% of U n for U n = 520 V ac (ph-ph) Frequency 4565 Hz Maximum measured voltage 360 V ac Overvoltage allowance 750 V ac (up to) Consumption < 0.5 VA Current inputs Measurement range from 1 to 120% of I n for I n = 5 A Secondary CT (I n ) 1 or 5 A Primary current Programmable < 30000 A Excess load admitted 6 A permanent ; 100 A t<1 s Consumption < 0,45 VA Auxiliary supply Power supply 80 to 265 V ac (50 - 60 Hz) (consumption < 30 VA) 90 to 300 V dc (consumption < 25 W) Digital inputs Operation voltage of 24 to 60 V dc 20 % Minimum signal width 30 ms Consumption (per input) < 0,5 W Accuracy (type 402) Currents (I) 0,2 % from 10 % ...120 % of I n Voltage (V) 0,2 % from 20 % ...120 % of U n /U n Active power P 0,2 % from 10% ... 120 % of I n Reactive power Q 0,5 % from 10 % ... 120 % of I n Apparent power S 0,5 % from 10 % ...120 % of I n Frequency F 0,01 Hz from 45 to 65 Hz Active energy 0,2 % Reactive energy 0,5 % Apparent energy 0,5 % Digital pulse outputs Type Optocoupler Operation voltage 24 dc Maximum power (per output) 0.6 W Digital relay outputs Type Mechanical relay Operation voltage 250 V ac Maximum current (resistive load) 3 A Analogue output Scale from 0 . 20 mA or 4 20 mA Maximum admitted load 500 Response time < 2 s Output range points 4000 Communications Type RS-485 Protocol ModBus / RTU Speed (confgurable) 9600, 19200, 38400, 57600 baud Parity odd, even or no parity Stop bits 1 or 2 Ethernet output Type Ethernet - RJ45 Protocol Modbus / TCP Speed 10 baseT / 100baseT (x) ENVIRONMENT Operation temperature - 10... + 50 C Storage temperature - 20... + 65 C Relative humidity 95% without condensation Installation category CAT III according to IEC 61010 Level of contamination 2 according to IEC 61010 Protection index IP51 front IP20 rear section MECHANICS Connection Screw terminal block for rigid wires of 2.5 mm (4.5 mm 2 ) or fexible wires REGULATION REFERENCES CEM 61000-4-2, 61000-4-3, 61000-4-11, 61000-4-4, 61000-4-5 CVMk2 Three-phase power and power quality analyzer 6 CVMk2 APPLICATION NOTE Three-phase power and power quality analyzer CVMk2 Series Type Code Class Communication Protocol COMPACT EQUIPMENT (measurement module + Display) CVMk2-ITF-405 [*] M54400 0,5 RS-485 Modbus/RTU CVMk2-ITF-402 [*] M54402 0,2 RS-485 Modbus/RTU
MEASUREMENT EQUIPMENT (measurement module) M-CVMk2-ITF-405 [*] M54410 0,5 RS-485 Modbus/RTU M-CVMk2-ITF-402 [*] M54412 0,2 RS-485 Modbus/RTU Exchangeable modules Type Code outpus SD memory digitals inputs / ouputs analogue inputs / ouputs Protocol Communication k2-EXP-8I / 8O-Digital-TR [*] M54501 Trans.(*) - 8/8 - - - k2-EXP-8I / 4O-Analog [*] M54502 - - - 8/4 - - k2-EXP-8I / 4O-Digital-RL [*] M54503 Relay - 8/4 - - - k2-EXP-SD- MODBUS/TCP [*] M54504 - 512 Mb - - Ethernet Modbus/TCP k2-EXP-SD-Memoria [*] M54506 - 512 Mb - - - - (*) optocoupled transistor output C V M k 2 M 5 X X X X 0 0 X X Code Internal code Power supply voltage (TA) Standard 85...265 V ac 95...300 V dc 0 SDC 24...90 Vc.c. 8 Tensin measurement (TM) f-n / f-f Standard (300/520 V ac) 0 63,5 / 110 V ac 1 500 / 866 V ac 3 CVMk2 Three-phase power and power quality analyzer 7 CVMk2 APPLICATION NOTE Three-phase power and power quality analyzer CVMk2, wiring diagram conexion 4CT and 5 voltage references 3CT and 4 voltage references CVMk2, Dimensions 144 144 168 72 17 27