You are on page 1of 3

CALCULATION SHEET

Formula Scaffolding Ltd JOB TITLE: Nyria Way


70 High Street
West End SUBJECT: Design check
Southampton
Hants CUSTOMER: Kier Services

SO30 3DU
Tel: 02380 466900 MADE BY: Wayne Lovelock Date:28/09/12


--------------------------------------------------------------------------------------------------------

Codes used in this design

TG20:08 volumes 1 and 2 Technical guidance on the use of BSEN12811-1.
BSEN12811-1
BS5975:2008 Code of practice for temporary works procedures
BS6399-2: 1997 loadings for buildings-code of practice for wind loadings
NASC guidance notes.
BSEN 1991-1-3 and 4 snow and wind loadings.

Materials used
Scaffold tube
Type 4 BSEN 39. BS1139:1992

Diameter 48.3mm 48.3mm
Wall thickness 4.0mm 4.0mm
Weight 4.37kg/m 4.37kg/m
Cross section area 5.57cm 5.57cm
Second moment of area I= 13.8cm4 13.8cm4
Radius of gyration r= 1.57cm 1.57cm
Yield stress fy= 235N/mm 210N/mm
Plastic modulus Sp= 7.87cm 7.87cm
Safe working Moment Mc= 1.12kn.m 1.00kn.m
Safe working shear force = 29.2kn. 26.1kn
Safe axial load as TG20:08 table 20 and 40.

Scaffold Boards BS 2482. Specification

Scaffold Fittings see TG20:08 table 24

Ladder beams steel, permissible bending 13.5kn.m, permissible shear 18.0kn.
450mm aluminum beams (Generation) permissible bending 13.9kn.m, permissible shear 12.3kn.
Diamond aluminum beams (Generation) permissible bending 39.5kn.m, permissible shear 33.5kn

Job No. 147 Sheet 1 of 3 Rev:

CALCULATION SHEET


Formula Scaffolding Ltd JOB TITLE: Nyria Way
70 High Street
West End SUBJECT: Double width independent.
Southampton
Hants CUSTOMER: Kier Services

SO30 3DU
Tel: 02380 466900 MADE BY: Wayne Lovelock Date: 28/09/12

CHECKED BY: Date:


-------------------------------------------------------------------------------------------------------------------
The independent scaffold erected to the girth of the block is a basic scaffold as defined by Tg20:08 4.4.2. It has a
load class 3 with each lift boarded ( 2.0kn/m2 on one lift and 1 .00kn/m2 on a second lift).
Wind load S factor = 22 x 1.00 x (1+10/1000)=22.22 < 40 ( 4.4.2-7).

One element of the scaffold to rear adjacent the balconies is a double width independent at the base lift which
needs a further design check, and a loading bay adjacent the scaffold with a 10kn/m2 loading needs a design check.

Double width to the rear.

Load = 2.00kn/m2. Inner bay at 4bds wide and outer bay up to 7 bds wide.

Load to transoms from inner bay, 2.00kn+0.25kn x 1.2= 2.7kn/m.
2.7kn x0.9= 2.43kn. Bm= 2.43 x0.9/8=0.27kn.m < 1.12kn.m therefore acceptable.
End reaction 2.43/2=1.22 to the centre ledger.

Load to transoms from outer bay, 2.00kn+0.25kn x 1.2=2.7kn/m
2.7kn x 1.58=4.3kn. Bm 4.3 x1.58/8=0.85kn.m therefore acceptable.
End reaction to centre ledger= 4.3kn/2=2.15kn.

Max load to centre ledger from CPL of each transom = 1.22+2.15=3.37kn.

Bm to ledger 3.37x2/4=1.68kn.m > 1.12kn, therefore use a twin ledger as the centre ledger on the base lift.
1.68kn.m < 2 x 1.12kn.m, therefore acceptable.









Job No.147 Sheet 2 of 3 Rev:


CALCULATION SHEET

Formula Scaffolding Ltd JOB TITLE: Nyria Way
70 High Street
West End SUBJECT: Loading bay
Southampton
Hants CUSTOMER: Kier Services.

SO30 3DU
Tel: 02380 466900 MADE BY: Wayne Lovelock Date: 27/09/12.

CHECKED BY: Date:


-------------------------------------------------------------------------------------------------------------------
The loading bay is to be 2 (5 board) bays wide complete with each lift boarded and up to 6m long. Loading to be
one lift at any time at 10kn/m2.

Load to boards with transoms at 600mm.. 10+0.25kn x 0.6=6.15kn/m.
Bm 6.15 x 0.6 x0.6/8=0.28kn.m <0.71kn.m therefore acceptable.

Load to transoms.
10.25kn x 0.6 x 1.13m=6.95kn.
Bm 6.95 x 1.13/8=0.98kn.m <1.12kn.m therefore acceptable.

End reaction to transoms 6.95kn/2=3.48kn.

Load to ledgers at max 1.2centres.
Centre ledger Bm 6.95kn x 1.2/4=2.09kn > 1.12kn.m, therefore reduce centre standard spacings to 0.6m
Bm 6.95 x 0.6/4=1.04< 1.12kn.m therefore acceptable.

Load to ledgers ( outside) worst case CPL
Bm 3.34kn x 1.2/4=1.00< 1.12kn.m therefore acceptable.

Check load to standards.
Worst case centre standard.
Load 10.25kn +0.25= 10.50 x 1.2 x 0.6=7.56kn. ( use check fittings on centre ledgers 2 x 6.1kn >7.56kn)
Pc at 2.0m = 28.2>7.56 therefore acceptable.

Summary.

Outside bay size 1.2m, inner standards at 0.6m
Lift heights 2m to match independent scaffold.
Transoms at 600mm centres.
Only 1 lift to be fully load at a time.
Brace externally over 3 sides (allowing for chute and hoist.), wing brace 2
nd
and 4
th
lift to the independent,
internally ledger brace every other standard to on bay only.
Job No. 147 Sheet 3 of 3 Rev: