Column reinforcement & column grouping

Required reinforcement
Sl COLU
NO MN
No

Size

Up to
plinth

GF

FF

SF

TF

Steel provided
Colu
mn
Critical
type

No of bars & Dia

Ast in
sqmm

Result

20 300 X 450

699

1969 2179 1419

2179

C1

8-20 mm

2512

SAFE

15 300 X 450

1029

2049 2119 1429

2119

C1

8-20 mm

2512

SAFE

16 300 X 450

1059

1959 1769 1059

1959

C2

4-20 mm & 4- 16 mm

2060

SAFE

19 300 X 450

929

1869 1809 1049

1869

C2

4-20 mm & 4- 16 mm

2060

SAFE

2 300 X 450

609

1439 1649 1459

1649

C2

4-20 mm & 4- 16 mm

2060

SAFE

3 300 X 450

609

1439 1649 1459

1649

C2

4-20 mm & 4- 16 mm

2060

SAFE

1 300 X 450

599

1389 1619 1429

1619

C3

8-16 mm

1608

SAFE

4 300 X 450

599

1389 1619 1429

1619

C3

8-16 mm

1608

SAFE

6 300 X 450

1049

1419 1279 1249

1419

C3

8-16 mm

1608

SAFE

10

7 300 X 450

1049

1419 1279 1249

1419

C3

8-16 mm

1608

SAFE

11

5 300 X 450

889

1249 1169 1129

1249

C4

4-16 mm & 4- 12 mm

1256

SAFE

12

8 300 X 450

889

1249 1169 1129

1249

C4

4-16 mm & 4- 12 mm

1256

SAFE

13

13 300 X 450

919

1189 1159 1169

1189

C4

4-16 mm & 4- 12 mm

1256

SAFE

14

12 300 X 450

929

1179 1159 1169

1179

C4

4-16 mm & 4- 12 mm

1256

SAFE

15

11 300 X 450

919

1079 1079 1079

1079

C4

4-16 mm & 4- 12 mm

1256

SAFE

16

14 300 X 450

919

1079 1079 1049

1079

C4

4-16 mm & 4- 12 mm

1256

SAFE

17

17 300 X 300

1469

1869 1499

739

819

1869

C5

4-20 mm & 4- 16 mm

2060

SAFE

18

18 300 X 300

1469

1859 1499

739

819

1859

C5

4-20 mm & 4- 16 mm

2060

SAFE

19

9 300 X 300

1259

1349 1269

779

639

1349

C6

4- 16 mm

1608

SAFE

20

10 300 X 300

1329

1349 1269

779

639

1349

C6

4- 16 mm

1608

SAFE

21

21 300 X 300

709

1189 1249

869

1249

C7

4-16 mm & 4- 12 mm

1256

SAFE

22

24 300 X 300

709

1209 1239

859

1239

C7

4-16 mm & 4- 12 mm

1256

SAFE

23

22 300 X 300

579

1049 1139

639

1139

C7

4-16 mm & 4- 12 mm

1256

SAFE

24

23 300 X 300

579

1049 1129

639

1129

C7

4-16 mm & 4- 12 mm

1256

SAFE

25

25 300 X 300

489

989

939

729

989

C7

4-16 mm & 4- 12 mm

1256

SAFE

26

26 300 X 300

489

989

939

729

989

C7

4-16 mm & 4- 12 mm

1256

SAFE

SUPPORT REACTIONS AND FOOTING GROUPING


Sl No

JOINT

LOAD

FORCE-X FORCE-Y FORCE-Z

MOM-X

MOM-Y

MOM Z

Footing
type

16

36

-7.78

619.06

-8.68

-6.05

0.01

4.81

F1

19

36

-3.83

584.47

-8.65

-6.04

-0.01

2.54

F1

18

36

-4.09

582.05

-9.89

-6.62

0.01

2.67

F1

17

36

4.19

581.46

-9.9

-6.62

-0.01

-2.69

F1

12

36

1.79

577.4

0.11

-0.41

0.02

-0.78

F1

36

1.75

577.09

-1.1

-1.18

-0.02

-0.78

F1

36

-1.75

577

-1.08

-1.15

0.02

0.78

F1

13

36

-1.98

576.96

0.06

-0.45

-0.02

0.95

F1

36

-1.71

576.77

-1.16

-1.28

0.67

F1

10

36

1.7

576.7

-1.15

-1.26

-0.66

F1

11

11

36

-1.71

573.88

-0.04

-0.45

0.01

0.68

F1

12

14

36

1.84

573.4

-0.1

-0.5

-0.03

-0.7

F1

13

15

36

10.22

536.83

-6.93

-4.86

-0.02

-6.56

F2

14

20

36

1.52

502.59

-6.9

-4.86

0.05

-0.04

F2

15

36

0.24

445.07

11.4

7.04

-0.22

F2

16

10

36

-0.26

445.07

11.4

7.05

0.26

F2

17

36

-10.65

420.11

8.61

5.01

6.75

F3

18

36

10.65

420.07

8.6

-6.74

F3

19

36

10.52

419.98

8.64

5.1

0.03

-6.43

F3

20

36

-10.52

419.94

8.63

5.08

-0.03

6.44

F3

21

22

36

-7.66

368.71

2.2

1.12

4.91

F4

22

23

36

7.39

367.45

2.26

1.15

-4.69

F4

23

26

36

-1.43

324.92

-1.8

-1.38

0.01

0.95

F4

24

25

36

1.37

324.88

-1.8

-1.38

-0.01

-0.87

F4

25

21

36

10.75

265.38

-1.41

-1.16

-0.01

-6.95

F4

26

24

36

-10.57

264.16

-1.33

-1.12

0.05

6.88

F4

Load calculations
name of the work: C/O Dormitory block in APSWRS(B) complex at station Ghanpur (v&m) in
Warangal Dist.
I. wall loads
A) Brick masonary walls
230 mm thick and
3.095 height.
0.23x3.095x20 =
or say
B)

Brick masonary walls (parapet)

230 MM thick and

14.237 KN/m
14.3 KN/m
1 height.

0.23x1x20 =
or say
Brick masonary walls (head
C) room)

230 MM thick and

2.075 height.

0.23x2.075x20 =
or say

D)

Brick masonary walls UNDER


MID LANDING BEAM

230 MM thick and

Brick masonary partition walls

115 MM thick and

FLOOR LOADS
DEAD LOADS
i) For 125 mm thick roof slabs
dead load of slab = 25x0.125
floor finish

3.125
1.50
4.625
4.625

Total
or say
iv) staircase load Dead load
staircase span
=
waist slab thickness =
floor to floor distance =
width of landing
=
Slooped length of the flight=
weight of waist slab
=
weight of steps
=
floor finish @1.5 kn/mt =
Total udl on staircase beam=
or say
Live load on rooms
=
Live load on corridors
=
Live load on staircase
=
UDL on staircase beam =
4.8 X 4 /2 =
or say

4.8
0.175
3.5
1.5
3.74
11.46
3.09
3.60
18.16
19.00
3.00
4.00
4.00

Mts.
Mts.
Mts.
Mts.
Mts.
KN/m
KN/m
KN/m
KN/m
KN/m
KN/SQm
KN/SQm
KN/SQm

9.60 KN/m
10.00 KN/m

5.75 KN/m
5.8 KN/m

3.375 height.

0.115x3.375x19.2 =
or say
a)

9.545 KN/m
9.6 KN/m

1.25 height.

0.23x1.25x20 =
or say

E)

4.6 KN/m
4.6 KN/m

KN/sqm
KN/sqm
KN/sqm
KN/sqm

7.7625 KN/m
7.8 KN/m

Sl. ZONE
NO
.

PARAMETERS FOR SESMIC ANALYSIS


Sesmic intensity Importa Response
Dimensions of structure
factor Z
nce
reduction
factor I Factor R
L
B
H

1 II

0.1

17.38

19.03

Fundamental
natural period

Pz=.0
Px=.09 9H/(d
H/(d) )
15.3 0.330 0.316

Wind load
Design wind pressure Pz =
Design wind speed =Vz=k1k2k3xVB
VB besiC wind speed
Probability factor = k1
Terrain factor
= k2
Topography factor= k3

=
=
=
=

0.6(Vz)2

44 M/SEC
1.00
1.02
1.00
Vz
= 1.08x1.02x1.00x44
= 44.88
Pz /Pd 0.6(Vz)2
=
= 0.6(44.88)^2 1209 N/m2
OR Say
1.21 KN/M

ONE WAY SLAB DESIGN


Slab panel size Lx
Slab panel size Ly
Slab thickness D
Dia of main rod provided d
Dia of distribution of rod provided d1
Cover c
Properties of concrete -M 15, 20,25
Efective slab thickness in x direction = D-d/2-c
Efective slab thickness in y direction
Effective span in short direction (Lx)
Effective span in long direction (Ly)
Ly/Lx

2.23
5.25
125
8
8
20
25
20
101
93
2.331
5.343
2.292

mts
mts
mm
mm
mm
mm
mm
mm
mts
mts

Required spacing =
Provide spacing =

272 mm C/C
200 mm C/C

Check for deflection = SAFE

one way slab


Span Condition
Continous-26,Simply supported-20
26
Loads on the slab
a) Dead load of slab
3.125 KN
b) Wt of flooring
1.500 KN
c) Wt of partitions
0.000 KN
Total load
4.625 KN
Factored load
Wd
6.938 KN
d) Live load
3.000 KN
Factored load
Wl
4.500 KN
Boundary conditions
Near middle of end span Cdsp-1/12 & Clsp-1/10
Near middle of interior span Cdsp-1/16 & Clsp-1/12
At support Next to the End support Cdsu-1/10 & Clsu 1/9
At other interior support Cdsu-1/12 & Clsu 1/9
Cdsp
1/12
Clsp
1/10
Cdsu
1/10
Clsu
1/9
Factored moments
Max +ve BM
5.586 KN/m
Max -ve BM
6.486 KN/m
positive reinforcement
Mu/bd*d
0.548
Pt
0.157
Ast required
158 mm^2
Required spacing
318 mm C/C
Provide
252 mm^2
Negative reinforcement
Mu/bd*d
0.636
Pt
0.183
Ast required
185 mm^2
Required spacing
272 mm C/C
Provide
252 mm^2
Hence SAFE

Distribution steel
Asd
=
150
Required spacing =
335

Check for deflection


Actual span/ Effective depth
22.08
Ast required
158 mm^2
Ast provided
252 mm^2
Fs
150.92
Modification factor MF
2.99
Allowable span/Effective 77.82
depth

Design of roof slab


Slab =

S1

Fy =
Fck =
Clearcover

415 N/mm
20 N/mm
20 mm

Ly =
Lx =

Slab thickness =
D.L.of slab =
Floor finishes =
Live load =
Total

125 mm
3.13
1.50
2.00
6.63 kN/m

Beam width
Ley =
Lex =
dx=
dy=

Ly/Lx =

5.230 m
4.700 m

200 mm
5.131 m
4.601 m
101
93

1.115

Ast Required

Edge Condition= Two Adjacent edges discontinuous


Mx- = x*1.5*w*lx =
0.057
11.97 kN-m
Mx+ = x*1.5*w*lx =
0.043
8.98 kN-m

My- = y*1.5*w*lx =
My+ = y*1.5*w*lx =
Check for deflection
fs =
Pt =
d required =
d provided =
Slab =

0.045
0.034

156
0.40
88.5
101.0 O.K

9.54 kN-m
7.15 kN-m

Modification factor =

Ast Provided

Ast
354
260

8 mm
142 c/c
193

8
125
125

305
224

8 mm
165 c/c
224 c/c

8
150
150

2.00

S1

Fy =
Fck =
Clearcover

415 N/mm
20 N/mm
20 mm

Ly =
Lx =

Slab thickness =
D.L.of slab =
Floor finishes =
Live load =
Total

125 mm
3.13
1.50
4.00
8.63 kN/m

Beam width
Ley =
Lex =
dx=
dy=

Ly/Lx =

230 mm
3.631 m
2.951 m
101
93

1.230

Ast Required

Edge Condition= One short edge discontinuous


Mx- = x*1.5*w*lx =
0.049
Mx+ = x*1.5*w*lx =
0.037

My- = y*1.5*w*lx =
My+ = y*1.5*w*lx =
Check for deflection
fs =
Pt =
d required =
d provided =

3.760 m
3.080 m

144
0.25
56.8
101.0 O.K

0.037
0.028

Ast Provided

5.56 kN-m
4.17 kN-m

Ast
158
150

8 mm
319 c/c
335

8
200
200

4.13 kN-m
3.10 kN-m

150
150

8 mm
335 c/c
335 c/c

8
200
200

Modification factor =

2.00

DESIGN OF FOOTING

F1
Load
Mx=
Mz=
Sbc of soil=
Fck=
Fy=
Clear cover =
Pedestal Y
Pedestal X
Area of footing=
Ly=
Lx=

619.06
6.05
4.81
200
20
415
50
0.45
0.60

kN
kN-m
kN-m
kN/m
N/mm
N/mm
mm
m
m

3.40 m
Required
1.77 m
1.92 m

Gross Upward pressure


Net Upward pressure

198
181 kN/m

My =
Mx =

135.56 kN-m
108.96 kN-m

depth required =

Provided
1.90 m
1.90 m
which is less than S.B.C

18 -#10
1.90

160.8 mm
1.90

0.45
0.60

Provide overall Depth =


dx=
dy=

400 mm
345 mm
335 mm

Ast "X" parallel to longer dir=


Ast "Y" parallel to shorter dir=

1129.202 mm
900.906 mm

Parallel to Short Direction=


Parallel to Long Direction=
Check for oneway shear=
One way shear force 'X'=
One way shear force 'Y'=
One way shear stress 'v-x'=
One way shear stress 'v-y'=

Dia of bar
10
10

Required
18
18

201.164 kN
157.321 kN
0.316 N/mm
0.240 N/mm

Perm, shear stress 'X'=


c

Pt =
0.222
0.341 safe

Perm, shear stress 'Y'=


c
Check for twoway shear=
Two way shear force 'X'=
Two way shear stress 'v-x'=
Perm, shear stress =

Pt =
0.216
0.337 safe
778.43 kN
0.662
1.12 safe

18 -#10
Min Ast 'X' =
Min Ast 'Y' =
Provided
18
18

1311 mm
1311 mm

F2
Load
Mx=
Mz=
Sbc of soil=
Fck=
Fy=
Clear cover =
Pedestal Y
Pedestal X
Area of footing=
Ly=
Lx=

536.83
4.86
6.56
200
20
415
50
0.45
0.60

kN
kN-m
kN-m
kN/m
N/mm
N/mm
mm
m
m

2.95 m
Required
1.64 m
1.79 m

Gross Upward pressure


Net Upward pressure

194
177 kN/m

My =
Mx =

109.14 kN-m
86.23 kN-m

depth required =

Provided
1.80 m
1.80 m
which is less than S.B.C

13 -#10
1.80

148.2 mm
1.80

0.45
0.60

Provide overall Depth =


dx=
dy=

400 mm
345 mm
335 mm

Ast "X" parallel to longer dir=


Ast "Y" parallel to shorter dir=

903.933 mm
709.465 mm

Parallel to Short Direction=


Parallel to Long Direction=
Check for oneway shear=
One way shear force 'X'=
One way shear force 'Y'=
One way shear stress 'v-x'=
One way shear stress 'v-y'=

Dia of bar
10
10

Required
13
10

162.887 kN
122.166 kN
0.270 N/mm
0.197 N/mm

Perm, shear stress 'X'=


c

Pt =
0.169
0.303 safe

Perm, shear stress 'Y'=


c
Check for twoway shear=
Two way shear force 'X'=
Two way shear stress 'v-x'=
Perm, shear stress =

Pt =
0.164
0.299 safe
664.70 kN
0.565
1.12 safe

13 -#10
Min Ast 'X' =
Min Ast 'Y' =
Provided
13
13

745.2 mm
745.2 mm

F3
Load
Mx=
Mz=
Sbc of soil=
Fck=
Fy=
Clear cover =
Pedestal Y
Pedestal X
Area of footing=
Ly=
Lx=

420.11
5.01
6.75
200
20
415
50
0.45
0.60

kN
kN-m
kN-m
kN/m
N/mm
N/mm
mm
m
m

2.31 m
Required
1.45 m
1.60 m

Gross Upward pressure


Net Upward pressure

198
181 kN/m

My =
Mx =

71.94 kN-m
54.40 kN-m

depth required =

Provided
1.60 m
1.60 m
which is less than S.B.C

10 -#10
1.60

127.6 mm
1.60

0.45
0.60

Provide overall Depth =


dx=
dy=

350 mm
295 mm
285 mm

Ast "X" parallel to longer dir=


Ast "Y" parallel to shorter dir=

697.169 mm
523.029 mm

Parallel to Short Direction=


Parallel to Long Direction=
Check for oneway shear=
One way shear force 'X'=
One way shear force 'Y'=
One way shear stress 'v-x'=
One way shear stress 'v-y'=

Dia of bar
10
10

Required
10
8

126.207 kN
89.215 kN
0.277 N/mm
0.189 N/mm

Perm, shear stress 'X'=


c

Pt =
0.172
0.306 safe

Perm, shear stress 'Y'=


c
Check for twoway shear=
Two way shear force 'X'=
Two way shear stress 'v-x'=
Perm, shear stress =

Pt =
0.166
0.301 safe
517.18 kN
0.547
1.12 safe

10 -#10
Min Ast 'X' =
Min Ast 'Y' =
Provided
10
10

566.4 mm
566.4 mm

-#

DESIGN OF FOOTING

F4
Load
Mx=
Mz=
Sbc of soil=
Fck=
Fy=
Clear cover =
Pedestal Y
Pedestal X
Area of footing=
Ly=
Lx=

368.71
1.12
4.91
200
20
415
50
0.45
0.45

kN
kN-m
kN-m
kN/m
N/mm
N/mm
mm
m
m

2.03 m
Required
1.42 m
1.42 m

Gross Upward pressure


Net Upward pressure

191
175 kN/m

My =
Mx =

54.14 kN-m
54.14 kN-m

depth required =

Provided
1.50 m
1.50 m
which is less than S.B.C

10 -#10
1.50

114.4 mm
1.50

0.45
0.45

safe
safe
safe

Provide overall Depth =


dx=
dy=

300 mm
245 mm
235 mm

Ast "X" parallel to longer dir=


Ast "Y" parallel to shorter dir=

635.092 mm
635.092 mm

Parallel to Short Direction=


Parallel to Long Direction=
Check for oneway shear=
One way shear force 'X'=
One way shear force 'Y'=
One way shear stress 'v-x'=
One way shear stress 'v-y'=

Dia of bar
10
10

Required
10
10

113.921 kN
109.992 kN
0.323 N/mm
0.299 N/mm

Perm, shear stress 'X'=


c

Pt =
0.231
0.347 safe

Perm, shear stress 'Y'=


c
Check for twoway shear=
Two way shear force 'X'=
Two way shear stress 'v-x'=
Perm, shear stress =

Pt =
0.221
0.341 safe
464.56 kN
0.701
1.12 safe

10 -#10
Min Ast 'X' =
Min Ast 'Y' =
Provided
10
10

735 mm
735 mm

Design of Staircase
Span :

4.8 m

Over all Depth of the Slab =

175 mm

Effective Depth =

149 mm

(assumed)

Loads:
2
4.900 kN/m
2
1.875 kN/m

Self wt, wd =
Wt. Of steps =

2
4 kN/m
2
1.5 kN/m

Live Load =
Floor finish =
Total Working Load w =

2
12.28 kN/m

Factored Load, wu =

18.41 kN/m

Design moment :
consider 1m width of slab, wu =

18.41 kN/m

Mu.max = wuL / 12 =

35.35 kN.m

Check for Concrete Depth :


Mur.max =

Ru.max bd

61.27

Main Steel :
Required Ast =
Dia of bars =
Spacing, srqrd

822.61 mm
12 mm
=

Provide

137.42 mm
12 mm @

Check for Deflection


Sprov =

120 mm c/c

120 mm
2
942.00 mm

Ast.prov =
fs = 0.58 x fy x Ast.rqrd / Ast.prov =

210.1939

pt.prov =

0.63

modification factor
a1 =

1.29

Minimum effective depth required =

143.51 mm
safe

Distribution steel :
For Fe-415, pt.min = 0.12%
Ast =
Dia of bars =
Spacing, srqrd
Provide

2
210 mm
8 mm
239.24 mm

8 mm @

200 mm c/c

You might also like