You are on page 1of 1

9 ROOFTOP PHOTOVOLTAIC INSTALLATION TIPS

Dave Barista, Managing Editor September 1, 2009 Building Design and Construction Magazine

The popularity of rooftop photovoltaic (PV) panels has exploded during the past decade as Building Teams look to maximize building energy efciency, implement renewable energy measures, and achieve green building certication for their projects. However, installing rooftop PV systemsrack-mounted, roof-bearing, or fully integrated systemsrequires careful consideration to avoid damaging the roof system. Improper handling, storage, and installation of the PV panels can cause damage to the roof, which can lead to moisture intrusion, wind uplift problems, and even structural damage. In addition, rooftop PV systems should be designed with future maintenance, roof repairs, and re-suppression efforts in mind. BD+C asked a pair of roong experts to identify the most critical design, construction, and installation considerations. They offer the following tips: 1. Verify the fire rating of your rooftop photovoltaic system. Most rooftop PV systems qualify for a Class C re rating, while most of the roof coverings over which these systems are installed are re rated Class A or B, says Philip D. Dregger, PE, RRC, principal with roof and waterproong consultant Technical Roof Services Inc., Concord, Calif. Dregger says the re rating, especially spread of ame, is critical, especially for roof-bearing and rack-mounted systems. For instance, Building Teams may need to take steps like incorporating half-inch gypsum board into the assembly to obtain the proper re rating. For sloped roofs, Dregger says it is especially important to conrm that the required re classication is available at the slope required. For instance, standing-seam metal roofs routinely qualify as Class A re-resistant on unlimited slopes, whereas the same standing-seam metal roofs covered with thin-lm, exible PV panels have signicant slope restrictions, he says. 2. Flashing detail is critical for maintaining the warranty. Flashing detail work must be performed by a contractor approved by the roof membrane manufacturer, says Mike Ennis, technical director of the Single Ply Roong Industry (SPRI), Waltham, Mass., which recently convened a task force to identify key rooftop PV installation issues. Its not so much a difference in the details as it is that the details are properly completed, says Ennis. Building owners must get such permission in advance from the roofing manufacturer or the warranty may be voided. The main concern, says Ennis, is keeping a record of alterations to the roof system. For example, if a manufacturer gets a leak call immediately after an alternation is completed, they know where to start looking for the leak, he says. 3. PV systems must be properly marked. Marking is needed to provide emergency responders with appropriate warning and guidance with respect to working around and isolating the solar electric system. Proper marking helps responders identify energized electrical lines that connect the solar modules to the inverter, according to the California Department of Forestry and Fire Protections (CDFFP) Solar Photovoltaic Installation Guideline. Materials used for marking must be weather resistant and should be placed adjacent to the main service disconnect in a location clearly visible from the location where the lever is operated. 4. Make sure to protect the roof system while handling PV panels. Damage to roof systems, especially single-ply membranes,

often occurs during the handling of the PV panels. SPRIs Ennis offers four tips for avoiding roof system damage while moving and storing PVs: Store boxes PV units over joists to avoid deflecting the metal deck. If boxed units are palletized, place a cushion layer of plywood between the pallet and the roof surface. Do not point-load the roof surface by placing the corner of a hard panel directly on the surface. Use moving equipment fitted with pneumatic tires to transport equipment and materials over the nished roof surface. 5. In retrofit projects, consider roof life before installing PVs. Due to potentially high costs associated with temporarily disconnecting and moving PV panels to execute roof repairs, Building Teams should assess the remaining life of the existing roof covering as part of a PV project, says Dregger. He says serious consideration should be given to replacing the existing roof covering as part of a PV project. At the very least, says Dregger, you should investigate and repair roof leaks and perform any preventive-type maintenance work, even if it is not scheduled to be performed for a couple of years. 6. Pay close attention to the location of direct current (DC) conductors. Conduit, wiring systems, and raceways for photovoltaic circuits should be located as close as possible to the ridge or hip or valley and from the hip or valley as directly as possible to an outside wall to reduce trip hazards and maximize ventilation opportunities, according to the CDFFPs installation guidelines. DC combiner boxes should be located such that conduit runs are minimized in the pathways between arrays. To limit the hazard of cutting live conduit in venting operations, DC wiring should be run in metallic conduit or raceways when located within enclosed spaces in a building and should be run (to the maximum extent possible) along the bottom of load-bearing members. 7. Provide for fall protection in certain cases. In retrot projects, if the PV modules direct foot trafc to within six feet of unprotected roof edges or roof openings, fall protection provisions, such as guardrails and roof hatches, are a must, says Dregger. 8. Configure PV arrays to allow access for future maintenance, roof repairs, and fire-suppression efforts. CDFFPs installation guidelines recommend a minimum of six feet of clearance along the perimeter of the roof and at least four feet around roof access hatches and skylights. Also, pathways should be provided along the centerline of both axes of the roof. Locate these pathways over structural members. 9. Make sure integrated PV panels can handle high winds. For semi-rigid PV panels adhered over mechanically attached single-ply roofs, you need to make sure that the PV panels can accommodate billowing of the singly-ply membrane during high-wind conditions without incurring damage, such as cracking, splitting, or rupture. Dregger recommends installing air retarders and supplemental membrane fasteners around each PV panel to help avoid damage.

You might also like