Symbol
Description PVSPM PVSPM module giving priority to OSP + PVB Max. pump pressure = 350 bar Max. pump flow = 160 l/min. CF flow OSP = 60 l/min CF flow PVB = 100 l/min
PVSP modules 157B6708, 157B6728 and 157B6718 to be installed as the valve group end module instead of the PVS end plate
PVSP PVSP module giving priority tor OSP Max. pump pressure = 350 bar Max. pump flow = 160 l/min. CF flow OSP = 60 l/min
PVSPM PVSPM module giving priority to PVB Max. pump pressure = 350 bar Max. pump flow = 160 l/min. CF flow PVB = 100 l/min PVSP PVSP module giving priority to OSP With charge valve for supply of the braking circuit Max. pump pressure = 350 bar Max. pump flow = 160 l/min. CF flow OSP = 60 l/min 157B6718 (Open center) 157B6709 (Open center/ closed center)
03-2000
DKMH.PN.570.R1.02 520L0291
Book 8a partition 8
www.danfoss.com/fluidpower
PVSP/M
1. 2. 3. 4. 5. 6. 7. 8. 9. 10. PP orifice Dynamic orifice LS orifice for steering unit Spring for compensator spool Connection for LS-signal from steering unit Compensator spool for CF-connection PVSP housing Priority spool Plug, open-centre Plug, closed-centre
CF = controlled flow EF = excess flow Priority module PVSP contains a P-connection (for the pump) and a CF-connection. Accordingly, the standard pump connections in PVP, PVPVM and PVPDM must therefore always be provided with a steel plug (see example on page 3). The PVSP module can give priority to an OSP steering unit and/or a PVB 32 module. The excessive flow is passed on through EF to non-prioritised PVB 32 basic modules. If priority is solely given to the OSP steering unit (157B6708, 157B6728 or 157B6718), the PVSP module fills in the place of end plate PVS(I). When specifying valve groups of this nature, you are therefore not to give in any code number into field 11 in the specification form (see example on page 6). In valve groups that must give priority to PVB 32 (max. one PVB), PVSPM must be mounted as MidInlet (157B6707, 157B6728 and 157B6709). The PVB module that is given priority must be turned a 180 and installed on the right of PVSP (see orientation of ports on pages 4 and 5). PVSP-module 157B6718 includes an integrated charge valve that feeds the braking circuit through B1, B2 and B3. State the min required braking circuit pressure in the LSA field (see example on page 6). As the start/stop ratio of the charge valve is 1:1.2, a setting pressure of, for example, 200 bar will make the charge valve maintain a braking circuit pressure of 200-240 bar. If the working pressure of the valve exceeds the max permissible braking circuit pressure, a pressure reduction valve must be applied. Note: In prioritised PVB-modules, always remember to dismantle the LS shuttle valve (see example on page 3). And together with prioritised PVB modules, always use endplate 157B2018 (without O-rings). In open-centre systems, prioritised PVB-modules and steering units must always embody an integrated relief valve to avoid that an unintended, high pressure builds-up. In closed-centre systems, the system relief valve in PVP opens at a (max. 20 bar) higher pressure on the prioritised functions. It is therefore recommended to use PVB and OSP with integrated relief valve.
157B2018
Compensator spool for PVSP/M PVSP module 157B6709 contains no compensator as it solely gives priority to PVG 32. Accordingly, you are not to give in any code number into field 13.
DKMH.PN.570.R1.02
PVSP When specifying a PVG 32 valve group that contains a PVSP module, give in the code number into the field following the last PVB-module (in this case in field 6). Give in the code number of the compensator spool into field 13 (see example on page 6). For choice of stay bolt set PVAS, see page 4.
OSP dynamic
PVSPM Give in the code number of PVSPM into field 5. For PVSPM, select a PVS endplate without O-rings, code 157B2018 (see example on page 7) For choice of stay bolt set PVAS, see page 5
OSP static
Characteristics of PVSP/PVSPM
P P CFPVB
7 bar spring P P EF
DKMH.PN.570.R1.02
Dimensions
Valve group with PVPVM + PVSP Specification see page 6 Valve group with PVPD + PVSPM
Stay bolt set PVAS For pump pressures higher than 320 bar (however, no more than max. 350 bar) use PVAS 157B8041 157B8050
L2 140 189 238 287 336 385 434 483 532 581
Code number max. 320 bar 157B8001 157B8002 157B8003 157B8004 157B8005 157B8006 157B8007 157B8008 157B8009 157B8010
Code number max. 350 bar 157B8041 157B8042 157B8043 157B8044 157B8045 157B8046 157B8047 157B8048 157B8049 157B8050
Weight (kg) 0,15 0,25 0,30 0,40 0,45 0,50 0,60 0,65 0,70 0,80
In valve groups containing the above combination of modules, use PVAS stay bolt sets as specified in the survey.
DKMH.PN.570.R1.01
Dimensions
Valve group with PVPVM + PVSPM Specification see page 7 Valve group with PVPD + PVSP
LS: G 1/4
PVAS 157B8022 157B8030 are intended for pump pressures up to 350 bar In valve groups containing the above combination of modules, use PVAS stay bolt sets as specified in the survey.
1 2 3 4 5 6 7 8 9
Code number PVSPM PVSP 157B8022 157B8023 157B8022 157B8024 157B8023 157B8025 157B8024 157B8026 157B8025 157B8027 157B8026 157B8028 157B8027 157B8029 157B8028 157B8030 157B8029
Weigth (kg) PVSPM PVSP 0,3 0,35 0,3 0,45 0,35 0,5 0,45 0,55 0,5 0,65 0,55 0,7 0,65 0,75 0,7 0,85 0,75
DKMH.PN.570.R1.02
PVG No.
Subsidiary/Dealer
Function
A-Port
157B p=
2000 100 6130 5940 6233 100 6230 6233 220 6718 100 8005
bar
B-Port
a b a b a b a b a b a b a b a b a b a b
157B LSA
13
bar
157B 157B 157B 157B 157B 157B 157B 157B 157B 157B 157B 157B 157B 157B 157B 157B 157B 157B 157B 157B
c b c b c b c b c b c b c b c b c b c b
bar
LSB 157B
157B LSA
13
bar
157B 2100 157B 3171 157B 2001 157B 3171 157B 2002 157B 3171 157B 2250 157B 157B 157B 157B 157B 157B 157B 157B 157B 157B -
bar
LSB 157B
157B LSA
13
bar
bar
LSB 157B
157B LSA
13
bar
bar
LSB 157B
157B LSA
13
bar
bar
LSB 157B
157B LSA
13
bar
bar
LSB 157B
157B LSA
13
bar
bar
LSB 157B
157B LSA
13
bar
bar
LSB 157B
157B LSA
13
bar
bar
LSB 157B
10
157B LSA
13
bar
bar
LSB
11 12
Filled in by
157B 157B
Date
The above is an example specification of a PVG 32 valve group (shown on page 4) with PVSP, 157B6718, mounted. Note: The specification must be completed so that it covers the valve group seen from above. 6 DKMH.PN.570.R1.01
PVG No.
Subsidiary/Dealer
Function
A-Port
157B p=
2000 100 6130 5940 6233 100 6230 bar 6707 6233 220 2018 8025 bar bar bar bar bar bar bar bar bar bar
157B 157B 157B LSB 157B LSB 157B LSB 157B LSB 157B LSB 157B LSB 157B LSB 157B LSB 157B LSB 157B LSB
B-Port
a b a b a b a b a b a b a b a b a b a b
157B LSA
13
bar
157B 157B 157B 157B 157B 157B 157B 157B 157B 157B 157B 157B 157B 157B 157B 157B 157B 157B 157B 157B
c b c b c b c b c b c b c b c b c b c b
157B LSA
13
bar
157B 2100 157B 3171 157B 2001 157B 3171 157B 2002 157B 157B -
157B LSA
13
bar
157B LSA
13
bar
157B LSA
13
bar
157B 3171 157B 2250 157B 157B 157B 157B 157B 157B 157B 157B -
157B LSA
13
bar
157B LSA
13
bar
157B LSA
13
bar
157B LSA
13
bar
10
157B LSA
13
bar
11 12
Filled in by
157B 157B
Date
The above is an example specification of a PVG 32 valve group (shown on page 5) with PVSP, 157B6707, mounted. Note: The specification must be completed so that it covers the valve group seen from above. DKMH.PN.570.R1.02 7
Danfoss can accept no responsibility for possible errors in catalogues, brochures and other printed material. Danfoss reserves the right to alter its products without notice. This also applies to products already on order provided that such alterations can be made without subsequential changes being necessary in specifications already agreed. All trademarks in this material are property of the respective companies. Danfoss and the Danfoss logotype are trademarks of Danfoss A/S. All rights reserved.