You are on page 1of 4

Tech Note

Pump side modules PVPV and PVPVM for pumps with variable displacement

DKMH.PN.500.DC.02 replaces DKMH.PN.500.DB.02 Introduction With the introduction of PVPV and PVPVM, Danfoss is now able to supply pump side modules for systems with variable pumps. The new modules offer the following advantages: 1" P- and T-connection ports Lower pressure drop PVPVM enables the use of LS-pumps with flows up to 230 l/min Relief of pressure peaks with PVLP 63

Versions and code numbers

Symbol

Description
PVPV Closed center pump side module for pumps with variable displacement With pilot supply for electrical actuation Max pump pressure = 350 bar Max. pump flow = 150 l/min. PVPV Closed center pump side module for pumps with variable displacement With pilot supply for electrical actuation With chock and suction valve PVLP 63 Max pump pressure = 350 bar Max. pump flow = 150 l/min. PVPVM Closed centre pump side module for pumps with variable displacement With pilot supply for electrical actuation Max pump pressure = 350 bar Max pump flow = 230 l/min PVPVM Closed centre pump side module for pumps with variable displacement With pilot supply for electrical actuation With chock and suction valve PVLP 63 Max pump pressure = 350 bar Max pump flow = 230 l/min

Codenumbers P og T = G1

PVPV: To be installed in the same way as the standard range of PVP 32 pump side modules (see page 2).

157B5938

157B5941

PVPVM: To be installed as "mid inlet", i.e. that PVB 32 is to be mounted on both sides of the pump side module (see pages 2, 3 and belonging specification on page 4).

157B5937

157B5940

01-2000

DKMH.PN.500.DC.02 520L0222

Book 8 partition 3

www.danfoss.com/fluidpower

PVPV When ordering PVPV fitted with PVLP 63, please state the sales- and code No. in space 0 in the order form. Also, always state the PVLP 63 opening pressure in space 0.

Example
0 157B 5941 p = 100 bar 157B 2100 157B

PVPVM To order PVG 32 fitted with PVPVM, use standard order form HZ.57.A3.52 When ordering PVPVM fitted with PVLP 63, please state the sales- and code No. in space b in the order form. Also, always state the PVLP 63 opening pressure in space 0. (see example page 4)

Flowcharacteristics for PVPV/PVPVM Flow from PVB (without pressure compensator) left and rigth of PVPVM respectively. (For flow characteristics on PVPV, see catalogue HK.57.B1.02 page 23) Note that under certain circumstances systems with large pump flows may occasionally generate pressure peaks. For advice on systems of this nature, please contact the Danfoss sales organisation for hydraulics. 2

Set pressure difference between pump pressure and LS signal = 10 bar

Set pressure difference between pump pressure and LS signal = 15 bar

The oil flow depends on the pressure difference between pump pressure and LS-signal. Normally, the pressure difference can be set on the LS-pump control.

DKMH.PN.500.DC.02 520L0222

Dimensions PVPVM

MA og LS: G 1/4 For dimensions on PVPV and other PVPVM measures, see catalogue HK.57.B1.03.

Stay bolt set, PVAS for PVPVM In PVG 32 valve groups fitted with PVPV use standard PVAS, 157B8001 - 8010

Qty., basic module 2 3 4 5 6 7 8 9 10

L1 166 214 262 310 358 406 454 502 550

L2 213 262 311 360 409 458 507 551 600

L3 131 179 227 275 323 371 419 467 515

Code number 157B8022 157B8023 157B8024 157B8025 157B8026 157B8027 157B8028 157B8029 157B8030

Weight (kg) 0,3 0,35 0,45 0,5 0,55 0,65 0,7 0,75 0,85

DKMH.PN.500.DC.02 520L0222

Proportional Valve PVG 32 Specification


Customer Application

PVG No.

Subsidiary/Dealer

Function

A-Port

157B p=

2000 100 6130 bar 5940 6233 100 6230 bar 6233 220 bar bar bar bar

157B 157B 157B LSB 157B LSB 157B LSB 157B LSB 157B LSB 157B bar LSB 157B bar LSB 157B bar LSB 157B bar LSB 157B bar LSB

7004

B-Port

a b a b a b a b a b a b a b a b a b a b

157B 3171 157B 2100 157B -

157B LSA

13
bar

157B 157B 157B 157B 157B 157B 157B 157B 157B 157B 157B 157B 157B 157B 157B 157B 157B 157B 157B 157B

4216 2100 4016 2001 4016 2150 4116 2250

c b c b c b c b c b c b c b c b c b c b

157B LSA

7023 100 7002

13
bar

157B 2100 157B 3171 157B 2001 157B 3171 157B 2002 157B 3171 157B 2250 157B 157B 157B 157B 157B 157B 157B 157B 157B 157B

157B LSA

13
bar

157B LSA

13
bar

157B LSA

7021 220

13
bar

157B LSA

13
bar

157B LSA

13
bar

157B LSA

13
bar

157B LSA

13
bar

10

157B LSA

13
bar

11 12
Filled in by

157B 157B

2000 8024 Date

Example of a specification for a PVG 32 valve group (shown on page 3) fitted with PVPVM, 157B5940. Note that the specification must be filled in to correspond to the valve group seen from above. 4 DKMH.PN.500.DC.02 520L0222