You are on page 1of 29

IQ Products Electrical Aftermarket Products and Services

March 2006
Aftermarket Solutions, Ref. No. [191]

10-1

IQ Products

Contents
Description IQ Products Product Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Product History . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Product History Time Line . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . General Information Metering Selection Chart . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Protective Relay Selection Chart . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Technology Upgrades IQ DP-4000/4100 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . IQ Analyzer 6400/6600. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Power Xpert Meter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Current Products IQ Energy Sentinels. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . IQ 200 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . IQ 300 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . IQ Multipoint Energy Submeter II . . . . . . . . . . . . . . . . . . . . . . . . . . . . . MP-3000 Motor Protection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . FP-5000 Feeder Protection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Digitrip 3000 (DT-3000) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Accessories IQ Flange . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . IQ DC Power Supply . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . IQ Cable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . IQ Floor Mounted Enclosure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Addressable Relay II . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Power Modules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Discontinued Product Recommended Replacement IQ 2000 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . IQ Analyzer 6000/6200. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . RTD Modules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . IQ Data Plus and IQ Data Plus II . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . IQ 1000 and IQ 1000 II . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . IQ Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . IQ Generator . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Further Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Pricing Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 10-2 10-3 10-3 10-4 10-8 10-11 10-12 10-13 10-17 10-18 10-19 10-20 10-21 10-22 10-23 10-24 10-24 10-24 10-25 10-25 10-25 10-26 10-26 10-26 10-27 10-27 10-27 10-27 10-28 10-28

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24

Power Management Products

25

CA08105001E

For more information visit: www.EatonElectrical.com

10-2

IQ Products Electrical Aftermarket Products and Services


March 2006

Electronic Metering and Protection

Aftermarket Solutions, Ref. No. [192]

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25

Product Description
Eatons electrical business IQ Metering and Protection group of Cutler-Hammer products are multifunctional communicating products based on microprocessor technology. They are designed to replace existing electromechanical devices and can be applied at low, medium and high voltage points in the electrical distribution system. These devices offer communications capabilities to link electrical distribution equipment to Cutler-Hammer PowerNet Power Management Software. These products generally surpass capabilities available with older analog/electromechanical technologies. Depending on the features available from each device, information from these devices may be used to record and analyze power system and power quality events or problems and may improve power systems protection and coordination. With communications, these devices may be used for energy monitoring and management with trended data for use in future power system planning.

Power Management Products

For more information visit: www.EatonElectrical.com

CA08105001E

IQ Products Electrical Aftermarket Products and Services


March 2006
Aftermarket Solutions, Ref. No. [193]

10-3

Electronic Metering and Protection


power quality measurements, as well as harmonic plots, disturbance and transient waveforms, and an ITIC disturbance summary screen. Since then, the IQ Metering and Protection product family has grown to include additional products for both metering and protective functions. The IQ DP-4000 and the IQ AnaIyzer provide advanced metering functions including the ability to monitor power quality parameters. IQ Energy Sentinels provide a low cost method to monitor energy usage for individual feeders or loads. The IQ Multipoint Energy Submeter II provides cost-effective and spacesaving energy submetering for a wide variety of applications. The MP-3000 added increased motor protection capability. The FP-5000 introduced in 2001, provides overcurrent protection for distribution feeders.

Product History
Originally a Westinghouse Product
In the early 1980s, power metering and protective relaying functions were performed by electromechanical devices. Analog meters and induction disk protective relays were found on virtually every switchgear lineup manufactured up to that time. With the maturing of solid-state electronics, microprocessorbased replacements for the electromechanical devices became available. These new devices provided increased functionality and exibility, in a smaller space, for less cost. Westinghouse led the movement towards electronic metering and protection devices with the introduction of the IQ 2000 motor protection and control relay. In 1987, the IQ 2000 functions were split and two new products were introduced the IQ 1000 and the IQ Data Plus. The IQ 1000 provided all current monitoring and motor protection functions and was developed for use on AMPGARD medium voltage starters and low voltage motor control assemblies. The IQ Data Plus provided complete electrical metering and system voltage protection and was developed for use on low and medium voltage switchgear, as well as AMPGARD and low voltage motor control assemblies. The latest next generation addition to Metering is the Power Xpert Meter product series. The Power Xpert Meter power quality instrument monitors critical aspects of an electrical distribution system. This premier power quality metering instrument uses the latest in advanced technology to make it simple to use, powerful, scalable and highly exible. Power Xpert Meters offer a new level of intuitive user interface design, presenting critical electrical distribution system information in a simple to navigate and easy-tounderstand information architecture. The Power Xpert Meters graphic display visualizes the information from up to 16 Power Xpert PQ instruments. The embedded Web server displays complex power quality data using standard Internet browsers and allows for device conguration from the browser. Both the local graphic display and the embedded Web server present real time, historical and event information in a browser-style graphical format to help the user interpret key circuit information such as current loading, voltage and power levels, power factor, energy usage, I/O status,

1 2 3 4 5 6

Product History Time Line


Page 10-26 10-26 10-27 10-27 10-21 10-27 10-27 10-11 Product IQ 2000 Model (A) IQ 2000 Model (B) IQ 1000 IQ 1000 II MP-3000 IQ Data Plus IQ Data Plus II IQ DP-4000 AEM AEM II IQ 500 10-27 10-27 10-25 10-17 10-17 10-23 IQ Data IQ Generator AR (Addressable Relay) ARII (Addressable Relay II) IQ Energy Sentinel (Breaker Mount) IQ Energy Sentinel (Universal Mount) Digitrip MV DT-3000 CED CED II 10-12 10-26 10-12 10-13 10-22 10-18 10-19 10-20 IQ Analyzer IQ Analyzer 6000/6200 IQ Analyzer 6400/6600 Power Xpert 8000/6000/4000 FP-5000 IQ 200 IQ 300 IQ Multipoint Energy Submeter IQ Multipoint Energy Submeter II 1980 1985 1990 1995 2000 Present

7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25

Figure 10-1. Product History Time Line

CA08105001E

For more information visit: www.EatonElectrical.com

10-4

IQ Products Electrical Aftermarket Products and Services


March 2006

Metering Selection Chart

Aftermarket Solutions, Ref. No. [194]

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25

General Information
Table 10-1. Metering Selection Chart Dimensions in Inches (mm)
Device Name Accessories See Page 10-24 Power Xpert Series IQ 7000 Series IQ Analyzer 6000 Series IQ DP-4000 Series

Section Page Number

10-13 0.1% of Reading +0.02% FS 0.5% of Reading +0.01% FS 0.005 20 Amperes (400%) 0.1% of Reading +0.0025% FS 0.1% of Reading +0.0025% FS 0.1% of Reading +0.0025% FS 0.1% 0.1% 0.01 Hz 1% 1% ANSI C12.20 0.2 Class ANSI C12.20 0.2 Class ANSI C12.20 0.2 Class 0.5% of Reading +0.01% FS ANSI C12.20 0.2 Class ANSI C12.20 0.2 Class ANSI C12.20 0.2 Class ANSI C12.20 0.2 Class 85th 85th L-L, L-N, VAUX, L-L A, B, C, N, G Watt, Var, VA Apparent/Displacement Hz Amperes/Volts (L-L, L-N, AUX, L-L) L-L, L-N kW, kvar, kVA, Amperes 5 MB Limited to Size of CompactFlash Card Option (512 MB) 60 Cycles per Event 5 Max. 8 Via Status Input Yes Local/Computer

N/A 0.01% FS 0.01% FS 1% to 200% 0.05% 0.05% 0.05% 0.04% 0.04% 0.001 Hz 127th 127th 0.04% RV 0.04% RV 0.04% RV 0.05% RV 0.05% 0.05% 0.05% Exceeds ANSI C12 127th 127th L-L, L-N A, B, C, N or G Watt, Var, VA Displacement Hz Amperes/Volts All Up to 4 MB Up to 5760 cycles 32 Max. 32 Max. 8 Standard/64 Max. 64 Max. At Device Yes Local /Computer Local /Computer

10-12 0.2% FS 0.2% FS 3 800% 0.4% FS, Reading 0.4% FS, Reading 0.4% FS, Reading 0.8% FS 0.8% FS 0.04% or 0.01 Hz 50th 50th 0.5% Reading 1% Reading 0.5% Reading 0.2% FS 0.4% FS 0.4% FS 0.4% FS ANSI C12.20 (0.5%) 50th 50th L-L, L-N A, B, C, N, G Watt, Var, VA Apparent/Displacement Hz Amperes/Volts All Time/Date 504 Events with Timestamp 10 Waveform Events (4) 10 A Form C (4) 0 10/4 20 mA (3) + 30 Vdc Differential (1) 0 20/4 20 mA At Device or Via Communications Yes Local /Computer Local /Computer Legend

10-11 0.3% FS 0.3% FS 10 250% 0.6% FS 0.6% FS 0.6% FS 1.0% FS 1.0% FS 0.17% FS 31st 31st 0.6% FS 0.6% FS 0.6% FS 0.3% 0.6% 0.6% 0.6% L-L, L-N A, B, C Watt, Var, VA Apparent/Displacement Hz Amperes/Volts All 2 Alarms (3) 10 A Form C (1) kW Demand (1) kW Demand At Device or Via Communications Yes PG = Programmable FS = Full Scale RV = Read Value

Electrical Parameters
Volts Amperes Current Range (% of Nominal) Watts Vars VA PF-Apparent PF-Displacement Frequency THD-Voltage THD-Current Watthours Varhours VA-Hours Ampere-Demand Watt-Demand Var-Demand VA-Demand Revenue Accuracy Individual Ampere Harmonics Individual Voltage Harmonics

Minimum and/or Maximum Values


Volts Current Power Power Factor Frequency THD Flicker Demand Values Trend Analysis Event Logging Disturbance Recording

Other Features
PG Output Relays PG Analog Outputs Discrete Contact Inputs Analog Inputs Synch-Input kW Utility kWh Pulse Initiator Waveform Display Frequency Distribution Display

From 3 300% of FS. At unity power factory and 5 300% of FS. At a power factor <0.5 and 5 300% of FS. Under typical operating conditions. Individual values reported to 85th harmonic; anti-alias ltering prevents higher frequences from distorting readings (see IEC61000-4-7). Optional. Relays programmable to operate on any measured function.

For more information visit: www.EatonElectrical.com

CA08105001E

IQ Products Electrical Aftermarket Products and Services


March 2006
Aftermarket Solutions, Ref. No. [195]

10-5

Metering Selection Chart

General Information (Continued)


Table 10-1. Metering Selection Chart Dimensions in Inches (mm) (Continued)
Device Name Accessories See Page 10-24 IQ 300 IQ 200 Series IQ 100 IQ Energy/Power Sentinel IQ Multipoint Energy Submeter II

1 2 3 4

Section Page Number

10-19 0.5% FS 0.5% FS 1 200% 1.0% FS 1.0% FS 1.0% FS 2.0% FS 2.0% FS 0.1% Hz 1.0% Per ANSI C12 1.0% Per ANSI C12 1.0% Per ANSI C12 0.5% Per ANSI C12 1.0% Per ANSI C12 1.0% Per ANSI C12 1.0% Per ANSI C12 ANSI C12.1 (1%) L-L, L-N A, B, C Watt, Var, VA Apparent/Displacement Hertz All (2) 100 mA Form A (2) +30 Vdc Differential (1) 4 20 mA Via Communications Only Yes

10-18 0.5% FS 0.5% FS 1 200% 1.0% FS 1.0% FS 1.0% FS 2.0% FS 2.0% FS 0.1% Hz 1.0% Per ANSI C12 1.0% Per ANSI C12 1.0% Per ANSI C12 0.5% Per ANSI C12 1.0% Per ANSI C12 1.0% Per ANSI C12 1.0% Per ANSI C12 ANSI C12.1 (1%) L-L, L-N A, B, C Watt, Var, VA Apparent/Displacement Hertz All

N/A 0.5% FS 0.5% FS 5 120% 0.1% Hz

10-17 0.5% FS 0.5% FS 1.0% FS 1.0% FS 1.0% FS 2.0% FS 2.0% FS 0.1% FS 1.0% FS 1.0% FS

10-20 0.5% FS 1.0% FS 1.0% Per ANSI C12 1.0% Per ANSI C12 ANSI C12.1 (1%)

5 6 7 8 9 10 11 12 13 14 15 16 17 18

Electrical Parameters
Volts Amperes Current Range (% of Nominal) Watts Vars VA PF-Apparent PF-Displacement Frequency THD-Voltage THD-Current Watthours Varhours VA-Hours Ampere-Demand Watt-Demand Var-Demand VA-Demand Revenue Accuracy Individual Ampere Harmonics Individual Voltage Harmonics

Minimum and/or Maximum Values


Volts Current Power Power Factor Frequency THD Flicker Demand Values Trend Analysis Event Logging Disturbance Recording

(2) 100 mA Form A (2) +30 Vdc Differential (1) 4 20 mA Via Communications Only Yes

Via Communications Only Legend

Via Communications Only PG = Programmable FS = Full Scale RV = Read Value

Other Features
PG Output Relays PG Analog Outputs Discrete Contact Inputs Analog Inputs Synch-Input kW Utility kWh Pulse Initiator Waveform Display Frequency Distribution Display

19 20 21 22 23 24 25

IQ Power Sentinel only. IQ 115 only. At computer only. IQ 330/330M only. IQ 320 only. IQ 230/230M only. IQ 220 and IQ 230 models only.

CA08105001E

For more information visit: www.EatonElectrical.com

10-6

IQ Products Electrical Aftermarket Products and Services


March 2006

Metering Selection Chart

Aftermarket Solutions, Ref. No. [196]

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25

General Information
Table 10-1. Metering Selection Chart Dimensions in Inches (mm) (Continued)
Device Name Accessories See Page 10-24 Power Xpert Series IQ 7000 Series IQ Analyzer 6000 Series IQ DP-4000 Series

Section Page Number

10-13 LCD Graphic (320 x 240 Pixels) 5.5 mm H x 4 mm W

N/A LED Text /LCD Graphic Touchscreen LED 3 Lines/LCD Graphic RS-232, RS-485, Ethernet , Modem

10-12 Graphic LCD with LED backlight 7 Lines, 147 Characters Up to 7 Lines PowerNet

10-11 7 Segment LED 1 Line, 7 Characters 1 Line PowerNet

Other Features (Continued)


Display Type Display Lines/Character Display Character Height Communications

Modbus RTU, Modbus ASCII, Modbus TCP, Ethernet TCP/IP, HTML, FTP, INCOM Gateway (available 2006) Dimensions Meter 8.22 W x 8.82 H x 6.72 D (208.8 W x 224.0 H x 170.7 D) Display 7.80 W x 9.02 H x 2.49 D (198.1 W x 229.1 H x 63.2 D) Operating Temperature Range -20-60C Display Unit -20-70C Meter Base Unit (Using < 10 VA Meter Sourced 24 V Power) Physical Characteristics

10.50 W x 7.25 H x 3.40 D (266.7 W x 184.1 H x 86.4 D) Base -40C to +70C

6.70 (170.2) W x 10.30 (261.6) H x 5.40 (137.2) D

6.70 (170.2) W x 10.30 (261.6) H x 5.40 (137.2) D

-20 70C

-20 70C

Two-piece design (Power Xpert PQ Instrument + Remote Graphics display which supports up to 16 Power Xperts). Display/Meter mounting options: Display remotely mounted up to 4000 ft. away from up to 16 Power Xperts or Display OR Power Xpert mounted together on opposite sides of a panel (15 additional meters can still be remotely mounted). Perceptability (Total, L-L, L-N) PST (Total, L-L, L-N) PLT (Total, L-L, L-N) 6 Yes Yes Yes Yes Yes

Flicker (Per Phase)

Number of 9's of Availability Phasors Sequence Components Crest Factor K-Factor PQ Index Connectivity

Standard: RS-485 remote display port, RS-485 Modbus RTU Slave port, INCOM Gateway port (available 2006), RJ-45 10/100Base-T Local Conguration Port (local WEB server connection) Optional: Selectable 100F or 10/ 100Base-T Ethernet network port, RS-485 Modbus RTU Selectable Master/Slave port, RS-232 Modbus ASCII Slave port, Internal Modem (Future), Graphic Display, RS-485 meter display network port , RJ-45 10/1000Base-T for access to local display Power Xpert network , IRDA Port for access to Local Display Power Xpert Network

Optional. Display ports restrict access to up to 16 Power Xpert meters located on the display RS-485 network.

Legend

PG = Programmable FS = Full Scale RV = Read Value

For more information visit: www.EatonElectrical.com

CA08105001E

IQ Products Electrical Aftermarket Products and Services


March 2006
Aftermarket Solutions, Ref. No. [197]

10-7

Metering Selection Chart

General Information (Continued)


Table 10-1. Metering Selection Chart Dimensions in Inches (mm) (Continued)
Device Name Accessories See Page 10-24 IQ 300 IQ 200 Series IQ 100 IQ Energy/Power Sentinel IQ Multipoint Energy Submeter II

1 2 3 4

Section Page Number

10-19

10-18

N/A Red LED 3 Lines, 4 Characters

10-17

10-20 PowerNet

5 6 7 8

Other Features (Continued)


Display Type Display Lines/Character Display Character Height Communications LCD with LED backlight Backlit LCD 8 Numeric/ 10 Alphanumeric 2 Lines PowerNet , RS-485 4 Lines, 20 Characters

1.6 (4.06) H x .09 (2.3) W 2.25 (57.2) H x 2.0 (50.8) W PowerNet , RS-485 PowerNet

Dimensions

6.70 (170.2) W x 10.30 (261.6) H x 5.40 (137.2) D 0 50C

Refer to TD.17.06.T.E.

Refer to TD02601003E Refer to TD.17.07.T.E.

Refer to TD02601004E

9 10 11

Operating Temperature Range

0 50C

-20 70C

-25 70C

-25 70C

Physical Characteristics

12 13 14
Flicker (Per Phase)

15 16 17 18 19 20 21 22 23

Number of 9's of Availability Phasors Sequence Components Crest Factor K-Factor PQ Index Connectivity

IQ 320 only. IQ 330/330M only.

Legend

PG = Programmable FS = Full Scale RV = Read Value

24 25

CA08105001E

For more information visit: www.EatonElectrical.com

10-8

IQ Products Electrical Aftermarket Products and Services


March 2006

Protective Relay Selection Chart

Aftermarket Solutions, Ref. No. [198]

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25

General Information (Continued)


Table 10-2. Protective Relay Selection Chart
Device Name For Further Details and Information, See TD02600001TE. DT-3000 FP-5000 MP-3000

Technical Data Number

IEEE Device Number 32 67 67N 50 51 50G 51G 50G (N) 51G (N) 51VR

TD.17.10.T.E

TD02602003E 10

TD.17.11.T.E

Protection Functions
Directional Power Phase Directional Ground Directional Phase Inst. OC Phase TOC Calc. Residual Ground IOC Calc. Residual Ground TOC Ground Inst. OC (measured) Ground TOC (measured) Phase Voltage Restrained OC No. of Curves (ANSI/IEC/Thermal) TOC Time Reset Negative Sequence OC (unbalance) Negative Sequence Voltage Overvoltage Undervoltage Underfrequency Overfrequency Breaker Failure Zone Interlocking Thermal Overload Locked Rotor Jam/Stall Cold Load Pickup Loss of Load Power Factor

11

46 47 59 27 81U 81O 50BF 49 49S/51 51R

55 25

Control Functions
Synchronization Check Remote Open/Close Programmable I/O Programmable Logic Multiple Setting Groups Number of Starts Limit Starts per Hour Time Between Starts Emergency Restart Reduced Voltage Starting Trip Lockout (Trip Only)

For more information visit: www.EatonElectrical.com

CA08105001E

IQ Products Electrical Aftermarket Products and Services


March 2006
Aftermarket Solutions, Ref. No. [199]

10-9

Protective Relay Selection Chart

General Information (Continued)


Table 10-2. Protective Relay Selection Chart (Continued)
Device Name For Further Details and Information, See TD02600001TE. DT-3000 FP-5000 MP-3000

1 2 3 4

Technical Data Number

IEEE Device Number

TD.17.10.T.E

TD02602003E

TD.17.11.T.E

5 6 7 8 9 10 11 12 13 14

Metering Functions
Amperes Ampere Demand Volts Phase Angle Current Voltage Positive, Negative and Zero Sequence Watts Watt Demand Watthour Vars Var Demand Varhour VA VA Demand VA-Hour Frequency Trending (Load Prole) Minimum/Maximum Recording

Monitoring Functions
Trip Circuit Monitor Breaker Wear Failure to Close Oscillography Sequence of Events Trip Target Data Clock Number of Starts Acceleration Time RTD Temperature Hottest RTD

15 16 17 18

Communications
Local HMI Local Communication Port RS-232 Local Communication Port RS-485 Remote Communication Port FSK Addressable Protocols INCOM Modbus

19

Optional

20 21 22 23 24 25

CA08105001E

For more information visit: www.EatonElectrical.com

10-10

IQ Products Electrical Aftermarket Products and Services


March 2006

Protective Relay Selection Chart

Aftermarket Solutions, Ref. No. [200]

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25

General Information (Continued)


Table 10-2. Protective Relay Selection Chart (Continued)
Device Name For Further Details and Information, See TD02600001TE. DT-3000 FP-5000 MP-3000

Technical Data Number

IEEE Device Number

TD.17.10.T.E

TD.17.30.T.E

TD.17.11.T.E

Construction
Panel Mount Case Drawout Operating Temperature Range Power Supply Options Dual Source Power Supply ac Current Inputs ac Voltage Inputs Wye PTs Delta/Open Delta PTs Binary Inputs Alarm Outputs Trip Outputs Analog Outputs Local Display LEDs ( Local Targets ) 1 2 Form C 2

Optional -30C to 55C 120 240 Vac 24 250 Vdc Optional


-40C to 60C 48 125 Vac/dc 100 240 Vac/dc

Optional -20C to 60C 120 240 Vac


8 2 Form C 5 Optional

2 3 1 1


DT-3030 Only

Standards
ANSI IEC UL CE CSA

For more information visit: www.EatonElectrical.com

CA08105001E

IQ Products Electrical Aftermarket Products and Services


March 2006
Aftermarket Solutions, Ref. No. [201]

10-11

IQ DP-4000/4100 and Features and Benets

Technology Upgrades
IQ DP-4000/4100

Table 10-3. IQ DP-4000/4100 Ordering Information


Description Catalog Number

IQ DP-4000/4100

The Cutler-Hammer IQ DP-4000 is a microprocessor-based monitoring providing complete electrical metering and system voltage protection. In one compact, standard package the IQ DP-4000 will provide an alternative to individually mounted and wired conventional meters and switches. The new IQ DP-4000 also monitors Apparent Power (VA), Reactive Energy (Varhours), Apparent Energy (VA-Hours), and % Total Harmonic Distortion (THD) to provide the user with basic power quality information. The IQ DP-4000 meets and surpasses UL/CSA/CE standards.

Space savings in structure replaces conventional individual metering devices. Standardization of design one door-mounted device. Direct voltage input up to 600 V. New DIP switch design. Standardization of CT and PT connections. With additional PTs and set points, device can be used in HV setting. Relaying included in I/O module (Model 4100). Optional interface capability to computer network for data collection, storage and/or printout via PowerNet Eaton leading power distribution monitoring network. Retains present parameters through power failure with nonvolatile memory.

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25

Separate Source without I/O Capability IQDP4010 Separate Source control power without I/O, dc supply Three-Phase without I/O Capability Separate Source with I/O Capability IQDP4020 IQDP4030 IQDP4110

Separate Source control power with IQDP4120 three Form C relay output contacts and one sync pulse input, dc supply Three-Phase with I/O Capability IQDP4130

CA08105001E

For more information visit: www.EatonElectrical.com

10-12

IQ Products Electrical Aftermarket Products and Services


March 2006

IQ Analyzer 6400/6600

Aftermarket Solutions, Ref. No. [202]

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25

Technology Upgrades (Continued)


IQ Analyzer 6400/6600

Table 10-4. IQ Analyzer 6400/6600 Ordering Information


Description IQ Analyzer, Separate Source Power Module IQ Analyzer, 24 to 48 Vdc Power Module IQ Analyzer, 3-Phase Power Module IQ Analyzer, Separate Source Power Module with Waveform Display and Sub-Cycle Voltage Distribution Capture IQ Analyzer, 24 to 48 Vdc Power Module with Waveform Display and Sub-Cycle Voltage Distribution Capture IQ Analyzer, 3-Phase Power Module with Waveform Display and Sub-Cycle Voltage Distribution Capture IQ Flange, to Provide Extra Clearance When Mounting 45-inch Extension Cable for Remote Mounting of Power Module 24 to 48 Vdc Separate Source Power Module 100 240 Vac and 100 250 Vdc Separate Source Power Module 3-Phase, Self-Powered Power Module Catalog Number IQA6410 IQA6420 IQA6430 IQA6610 IQA6620 IQA6630 IQFLANGE IQA45CABLE IQMDCPM IQMSSPM IQM3PPM IPONI EPONI EPONIF WEBPONI MPONI IQDPAUXPS IQA6600PORTI

IQ Analyzer 6400/6600

The Cutler-Hammer IQ Analyzer 6400/ 6600 is a complete solution for users who want to monitor all aspects of their electrical distribution system. It provides extensive metering, power quality analysis, remote input monitoring, control relaying, analog input/outputs and communications capability. All programming can be done through the faceplate or through the communications option. Its online Help Pushbutton feature displays information on device operation, programming and troubleshooting.

INCOM Communication Module Ethernet Communications Module (10Base-T) Ethernet Communications Module with Fiber Optic Port (10Base-T and 10Base-FL) Web-Enabled Communications Module RS-485 Communication Module with Modbus Protocol IQ Analyzer/IQ DP-4000 Auxiliary Power Supply Portable IQ Analyzer with IPONI

Features and Benets


All information accessible through communications port. Quality true rms readings through 50th harmonic. Meets ANSI C12.16 Class 10 revenue metering specications. Accurate readings for non-sinusoidal wave forms with up to 3.0 crest factor. Screens display auto ranging units, kilo units, mega units as needed. 10 digit energy readings. Displays multiple parameters at the same time. Programmable custom screens.

The new IQ Analyzer Model 6600 with waveform display at the device and sub-cycle voltage disturbance capture provides the capability to monitor a wide range of harmonic parameters. These include harmonic voltage, current magnitudes and phase angles as well as system disturbances such as transient voltage disturbances and sub-cycle voltage interruptions.

For more information visit: www.EatonElectrical.com

CA08105001E

IQ Products Electrical Aftermarket Products and Services


March 2006
Aftermarket Solutions, Ref. No. [203]

10-13

Power Xpert Meter

Technology Upgrades (Continued)


Power Xpert Meter

Ease of Use
Power Xpert Meter Graphic Display
The Power Xpert Meter display features a large easy to read white backlit graphic LCD. The information presented by the display is organized into an information architecture that is easy to navigate and organized for simplicity. Screen navigation is accomplished using a Navigation Control Dial and a "back" button. The user simply twists the knob on the Navigation Control Dial to move between menu selections and drill down links on the screen. When the selection is highlighted, pressing the knob makes the selection. Information is displayed from a single meter or an RS-485 daisychain of up to 16 meters. The display features a rich set of screens including real time data, trend plots, waveform views and an ITIC Plot. The graphic display allows basic device setup and password protected resets. An audible alarm is available to annunciate alarm conditions.

Disturbance Information
Sag/swell recording 60 cycles of waveform are recorded at 256 samples per cycle including 30 cycles of pre and 30cycles of post event data. The Power Xpert Meter Embedded web server supports viewing of triggered waveforms one channel at a time and includes the ability to zoom and to scroll horizontally using a slider bar. Waveforms are stored in Power Xpert Meters non-volatile ash memory using an industry standard Comtrade format. Waveforms can be automatically sent out as Comtrade attachments to an email following an event, or can be retrieved from a ftp directory structure in Power Xpert Meters memory for viewing in Standard Comtrade viewers (available in 2006).

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25

Power Xpert Meter

General Description
The Power Xpert Meter power quality instrument monitors critical aspects of an electrical distribution system. This premier power quality metering instrument uses the latest in advanced technology to make it simple to use, powerful, scalable and highly exible. Power Xpert Meters offer a new level of intuitive user interface design, presenting critical electrical distribution system information in a simple to navigate and easy-to-understand information architecture. The Power Xpert Meters graphic display visualizes the information from up to 16 Power Xpert PQ instruments. The embedded Web server displays complex power quality data using standard Internet browsers and allows for device conguration from the browser. Both the local graphic display and the embedded Web server present real time, historical and event information in a browser-style graphical format to help the user interpret key circuit information such as current loading, voltage and power levels, power factor, energy usage, I/O status, power quality measurements, as well as harmonic plots, disturbance and transient waveforms, and an ITIC disturbance summary screen. The Power Xpert Graphic Display uses a simple twist and click navigation control dial to easily navigate the menus, select links to related pages, and to drill down into increasing levels of important detail. A back key enhances the browser like navigation of the graphic display. The Web server also provides the energy and demand readings required to help manage the cost of energy. The Power Xpert Web server also includes critical information regarding power quality such as harmonic distortion, icker, crest factor, K-factor and more.
CA08105001E

Historical Trend Logging


The Power Xpert Meter records historical data for graphical viewing from the Local display or the Embedded web server. Graphical views of historical data support pan and zoom. 138 standard metering parameters are logged as part of the standard meter functionality including min./max. and average for each parameter. The averages are calculated over the interval period. The minimum and maximum readings are based on 200 ms calculations. Storage capacity for standard trend plots:

Power Xpert Meter Embedded Web Server


The Power Xpert Meter embedded Web server offers Eaton customers a new level of accessibility to the critical information required to manage their electrical distribution system. The Web server includes real time circuit information in both numeric and graphical visual formats to help monitor circuit parameters such as current loading, voltage and power levels, power factor, thd, Flicker and more. The Web server also provides energy and demand readings with graphic useage plots to help analyze energy useage patterns. Energy readings include kWh, kvarh, delivered and received and kVAh with time of use and RTP displays. The interval energy usage plot includes the ability to show this month and last for benchmarking puposes. Both the Power Xpert Meter embedded Web server and the local graphic display support graphical trend charts of key circuit measurements such as current, voltage, power and energy. The trend chart supports a zoom feature that allows the user to view data over a short period of 18 hours up to 4 years. The trend chart includes zoom in/out buttons and a horizontal slider bar control to manage scrolling forward and backward through the data. Trend charts of basic readings include minimum, maximum and average readings. Trend charts of interval by interval energy data also display peak demand.

2 days of 5 minute interval min./ max./average data. 8 days of 15 minute interval min./ max./average data. 28 days of 1 hour interval min./max/ average data. 56 weeks of 8 hour interval min./ max./average data. 208 weeks of 1 week interval min./ max./average data.

Energy Prole data


The Power Xpert Meter records Real and Reactive energy forward, reverse, net and absolute sum, as well as Apparent energy (kVAh). Up to 8 status inputs can be congured as energy accumulators for counting KYZ pulse inputs. These readings are stored over a congurable interval from 1 to 60 minutes, as well as in daily and weekly totals. Storage capacity: 62 days of 15 minute interval energy and pulse interval data. Fixed interval capacity = 5952 intervals. Congurable intervals from 1 to 60 min.

For more information visit: www.EatonElectrical.com

10-14

IQ Products Electrical Aftermarket Products and Services


March 2006

Power Xpert Meter

Aftermarket Solutions, Ref. No. [204]

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25

Technology Upgrades (Continued)


372 days of 1 day accumulated energy and pulse interval data. 208 weeks of 1 week accumulated energy and pulse interval data.

Inputs and Outputs


Power Xpert Meter is available with an optional digital I/O card which includes: 8 digital inputs self sourced 24 Vdc. 3 relay outputs 5A maximum continuous, 380 Vac max., 125 Vdc maximum 2 solid state outputs 80 mA maximum continuous, 30 Vdc maximum.

Highlighting a eld such as the Avg. Current value and pressing the Navigation Control Dial brings up a detail screen like the one below

Event Triggers
The Power Xpert Meter supports 5 types of congurable event triggers:

Out of Limits, Demand Overload, ITIC, Sub-Cycle Disturbance and Fast Transient. These triggers permit pickup, reset and pickup delay to be congured by the user. When a trigger occurs, actions include Performance Monitoring (#9s analysis), Capturing Waveform, Capture Parameters, and Send Email, Operate a Relay Output. The Graphic Display ashes an LED to annunciate the alarm condition. An audible alarm is also available.

Each of the 8 inputs are interrupt driven, allowing for 1ms accuracy of digital events time stamps (1ms accuracy requires local NTP server). Inputs can also be congured for demand synch, and pulse counting. Inputs selected for pulse counting can be scaled. Interval by interval pulse recordings are maintained in Power Xpert Meters prole memory and can be displayed graphically. Outputs can be used for KYZ, or alarm annunciation.

Current Summary

Highlighting an individual reading on the detail summary level screen and selecting it drills down to a level including links to Min./Max., Historical Trend Plots, Triggers, Harmonic spectral data, and waveform viewing. Selecting the trend plot for a given parameter displays a historical graph of the selected parameter over the last 18 hours. The zoom buttons change the time scale to one of several data views based on historical averages with Min./Max. The Pan button allows scrolling within the selected view.

Power Xpert Meter Display Features


A menu-driven graphical display with information organized into a user friendly information architecture. The homepage (see below) offers: Graphical level indicator based on a statistical analysis for 3 phase Line to Line and Line to Neutral Voltage and per phase currents to quickly indicate out of normal readings Large easy-to-read average L-L voltage and average Phase currents and System Frequency can be highlighted and selected using the Navigation Control Dial to drill down for additional detail. Menu selections for Meter, Power, Quality, Events and Setup are shown for ease of navigation into display of more detail, or basic device setup.

Trigger options include:


Out of Limits over 100 triggers (105). Demand Overload 10 triggers ITIC 8 Triggers. Fast Transient dV/dT and Absolute per phase. Sub-Cycle disturbance dV/dT and Absolute

Event Logging
The Power Xpert Meter Local graphic display or the embedded Web Server allow the user to view a list of triggered events along with any captured parameters, event details, and triggered waveforms. In addition a separate event log includes a variety of activities including acknowledged triggers, new min. and max. events, and system operations such as resets. The size of the event log is virtually unlimited based only on the memory option selected.

Trend Plot

ITIC Analysis Plot


The Power Xpert Meter graphic display and Web server include a graphic display of the ITIC plot with counts of disturbances and transients that have occurred. The ITIC plot organizes events into 8 distinct disturbance zones corresponding to severity and a 9th zone for transients. A pass/fail count is displayed to indicate how many events are outside the ITIC limits. Clicking on any counter in the ITIC Web page will link the user to the event view and display all triggered events in the selected zone. This makes it simple to view disturbance waveforms associated with the ITIC plot.

Waveforms can be displayed for currents and voltages. The waveforms can be viewed on demand for steady state conditions. Triggered waveforms can also be displayed to view sag/ swell or transient data.

Homepage

Waveform Viewer

For more information visit: www.EatonElectrical.com

CA08105001E

IQ Products Electrical Aftermarket Products and Services


March 2006
Aftermarket Solutions, Ref. No. [205]

10-15

Power Xpert Meter Events Top Level Screen


Active/Aknowledged Event list, Trigger List, System Log, ITIC Curve Link. The web server allows the user to view waveforms of the voltage and current to spot power quality problems such as notching.

Technology Upgrades (Continued)

1 2 3 4 5

Event Detail Screens


Event List, Condition, Acknowledge Button, Trigger Date/Time, Trigger description.

Setup Top Level Screen


View setup, Edit setup, Login, Logout.

Setup Detail Screens


Quick Setup, Trigger setup, Detail setting.
Harmonic Spectrum

The Power Xpert Meter classies disturbances and summarizes the results graphically using the ITIC plot.

Harmonic Spectral Plot

6 7 8 9 10 11 12 13

The harmonic spectral plot displays both harmonics and interharmonics up to the 85th order. A detailed table also includes individual magnitudes and angles of current and voltage harmonics as well as a harmonic power calculation at each frequency. Even, Odd, Interharmonic, and total THD are displayed for diagnostic purposes.
Power Xpert Meter Homepage

ITIC Plot

The number of ITIC Sags and Swells are indicated for each of 9 severity levels. A Pass/Fail summary is shown to indicate how many events are outside the ITIC pass zone.

Power Xpert Meter Local Display Screens


Meter Top Level Screen
V-LL avg, V-LN avg, IA, IB, IC, Iavg, Freq.

Meter Detail Screens


Per phase detail L-L. L.N, Symmetrical Comp, Aux. Channels, Min./Max. with date/time of occurrence, Trend Plots, Triggers, Phasors.

Power Top Level Screen


3-Phase Power Factor, kWHr, kWd, Real Time kW, kvar, kVA, Load Prole Link.

Power Xpert Meter offers Eaton customers a new level of accessibility to the critical information required to manage the electrical distribution system. The Power Xpert Meter embedded Web server includes real time circuit information in both numeric and graphical visual formats to help monitor circuit parameters such as current loading, voltage and power levels, power factor. The Web server also provides the energy and demand readings required to help manage the cost of energy. Readings include kWh, kvarh, delivered and received and kVAh with time of use and separate status input controlled energy accumulation to account for energy during special times such as rate alert periods or standby generator times of operation. The Power Xpert Meter Web server also includes critical information regarding Power Quality such as harmonic distortion, icker, crest factor, K-factor and more.

Historical Trend Plot

14 15 16 17 18 19 20 21 22 23

Graphical Trending of Data


The Power Xpert Meter embedded Web server supports graphical trend charts of key circuit measurements such as current, voltage, power and energy. The trend chart supports a zoom feature that allows the user to view data over a short period of 18 hours or a longer period of 48 months. The trend chart has a horizontal slider bar control to manage scrolling forward and backward through the data. Trend charts of basic readings include minimum, maximum and average readings. Trend charts of energy data also display demand values.

Power Detail Screens


Per phase detail, kVA, kvar, kW, Min./ Max. with date/time of occurrence, Trend Plots, Triggers.

Quality Top Level Screen


10 min. and 24 hr. PQIndex, THDI, THDV, Kfactor, Crest Factor, Flicker Pst, %9s of Reliability.

Quality Detail Screens


Per phase detail L-L, L-N,V aux., Odd, Even, Interharmonics, Present, Min./ Max., Trend Plots, Harmonic spectrum plots, waveform plots.
CA08105001E

Steady-State Waveform Energy Load Prole

24 25

For more information visit: www.EatonElectrical.com

10-16

IQ Products Electrical Aftermarket Products and Services


March 2006

Power Xpert Meter

Aftermarket Solutions, Ref. No. [206]

1 2 3 4

Technology Upgrades (Continued)


Energy Managers can view load prole data compared against the peak demand. The plot allows comparison of present and past months usage.

RS-232 Modbus ASCII Slave port. Internal Modem (Future).

Graphic Display
RS-485 meter display network port. RJ-45 10/100Base-T for access to Local Display Power Xpert network. IRDA Port for access to Local Display Power Xpert Network.

Web Server Device Conguration

5 6 7
Disturbance Recording

Special software is not required to congure a Power Xpert Meter meter. The embedded Web Server includes comprehensive device set-up capability.

Note: Display ports restrict access to up to 16 Power Xpert meters located on the display RS-485 network.

Communication Protocols Supported


Metered/Monitored Parameters

8 9 10 11 12 13 14 15 16 17 18

Sag/Swell Recording
60 cycles of waveform are recorded at 256 samples per cycle including 30 cycles of pre and post event data. The Power Xpert Meter embedded Web server supports viewing of triggered waveforms one channel at a time including the ability to zoom and to scroll horizontally using a slider bar. Waveforms are stored in Power Xpert Meters non-volatile ash memory using an industry standard Comtrade format. Waveforms can be automatically sent out by email following an event, or can be retrieved from a FTP directory structure in Power Xpert Meters memory.

Volts: L-L, L-N, Avg. L-L, Avg. L-N, N-G. Phase neutral and ground currents. Power: real, reactive and apparent. Frequency. Power factor: apparent and displacement. Energy. Demand. % THD. Minimum and maximum values. Harmonics. Flicker. Number of 9s of availability. Phasors. Sequence Components. Crest Factor. K-Factor. PQ Index.

Modbus RTU, Modbus ASCII. Modbus TCP. Ethernet TCP/IP. HTML. FTP. INCOM Gateway (contact Eaton for availability).

Physical Characteristics
Two-piece design: Power Xpert PQ Instrument. Remote Graphics display (Supports up to 16 Power Xperts). Display/meter mounting options: Display remotely mounted up to 4000 ft. away from up to 16 Power Xperts. Display and Power Xpert mounted together on opposite sides of a panel. (15 additional meters can still be remotely mounted.)

Meter Characteristics
Height: 8.82 inches (224.1 mm). Width: 8.20 inches (208.3 mm). Depth: 6.72 inches (170.8mm) including optional wall mounting brackets. NEMA rating: NEMA 1.

Accuracy
Currents and voltages: 0.05% reading + 0.025% FS. Energy, and demand power: 0.10% of reading + 0.0025% FS. Frequency: 0.01 Hertz. Power Factor: 0.10% At Unity PF 0.30% at 0.5 PF.

Display Characteristics
Height: 9.02 inches (229.0 mm). Width: 7.8 inches (198 mm). Depth: 1.45 inches (36.8 mm) behind panel surface. 1.04 (26.3mm) projection in front of panel surface. NEMA rating: NEMA 12.

ITIC Analysis Plot

19 20 21 22 23 24 25

The ITIC Web page includes counters to track the occurrence of disturbances and a pass/fail summary. In addition, selecting any disturbance counter links to a detailed event view of the disturbances in that ITIC category. Disturbance waveforms can be viewed from the browser.

Communications
Multiple communications ports including:

Standard
RS-485 remote display port. RS-485 Modbus RTU Slave port. INCOM Gateway port (contact Eaton for availability). RJ-45 10/100Base-T Local Conguration Port (Local Web server connection).

Listings/Certications
Safety: EN61010-1, UL 61010A-1. Accuracy: IEC/EN60687 0.2 class, ANSI C12.20 0.2 Class. EMC: FCC Part 15 Subpart B Class A Immunity. IEC Standards: 50081-2, 61000-3, 61000-4, 61000-6.

Optional
Selectable 100F or 10/100Base-T Ethernet network port. RS-485 Modbus RTU Selectable Master/Slave port.

For more information visit: www.EatonElectrical.com

CA08105001E

IQ Products Electrical Aftermarket Products and Services


March 2006
Aftermarket Solutions, Ref. No. [207]

10-17

IQ Energy Sentinel
IQ Energy Sentinels with built-in CTs and communications have the added benet of greater overall system accuracy. Conventional metering often is less accurate since external CTs and separate transducers may each have inaccuracies of 1% or more. The IQ Energy Sentinel provides a unique and cost-effective method to implement energy submetering at lower levels in the distribution system economically. Or they may be installed when upgrading to Series C from older circuit breakers often with no additional space or modications required. The Universal Mount IQ Energy Sentinel with internal CTs may be utilized wherever breaker mounting is not feasible or possible. The Universal Mount IQ Energy Sentinel for external CTs may be utilized for monitoring loads larger than 400 amperes or when the use of existing CTs is desired. Table 10-5. IQ Energy Sentinels Ordering Information
Description For F-Frame Breakers For J-Frame Breakers For K-Frame Breakers Universal with Internal CTs Universal for External CTs

Current Products
IQ Energy Sentinels

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25

IQ Energy Sentinels

The Cutler-Hammer IQ Energy Sentinel is a highly accurate, microprocessorbased submeter designed to monitor power and energy readings. It represents an alternative to installing separate watt meters, watthour meters and watt demand meters. Key advantages include unmatched savings in space, lower installation costs, and the capability to communicate data readings in a variety of ways.

Submetering application examples for the IQ Energy Sentinel include energy monitoring and demand management, product cost analysis, process/machine tool efciency and productivity improvement. Additional applications include energy cost allocation of tenant billing for commercial, industrial, recreational and residential facilities.

Catalog Number IQESF_ _ _ IQESJ_ _ _ IQESK_ _ _ IQESUI_ _ _ IQESUE_ _ _

Retrotting
The space-saving design characteristics of the breaker mount IQ Energy Sentinels allow them to be added to existing Series C Circuit Breakers at any time often with no additional space or modications required.

Final three characters of catalog number are for voltage rating, i.e., 2 0 8 for 120/240, 240, 208Y/120 systems.

CA08105001E

For more information visit: www.EatonElectrical.com

10-18

IQ Products Electrical Aftermarket Products and Services


March 2006

IQ 200

Aftermarket Solutions, Ref. No. [208]

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25

Current Products (Continued)


IQ 200

One IQ 200 provides an alternative to an assortment of individually wired and mounted ammeters, voltmeters, ammeter and voltmeter switches, wattmeters, varmeters, power factor meters, frequency meters, watthour and demand meters. ANSI C12 Class 10 revenue metering accuracy make the IQ 200 an ideal choice for sub-metering and subbilling applications. The IQ 200 can be easily programmed and monitored from the faceplate keypad which features a 4 line x 20 character LED backlit LCD display. Opting for the compatible PowerNet system allows the user to program and monitor the meter remotely from a PC.

Table 10-6. IQ 200 Ordering Information


Description Catalog Number

IQ 210 Complete Meter IQ210 Includes Base, Display and 14-inch (355.6 mm) cable IQ 220 Complete Meter Includes IQ220 Base Display Module and 14-inch (355.6 mm) cable with INCOM Communications and KYZ Output IQ 230 Complete Meter with Base IQ230 Module, Display, and 14-inch (355.6 mm) Cable with INCOM communications, pulse output, 2 contact outputs, 2 digital inputs, 1 analog input and anti-tamper seal IQ 230M Complete Meter IQ230M with Base Module, Display, and 14-inch (355.6 mm) Cable with RS-485 Modbus communications, pulse output, 2 contact outputs, 2 digital inputs, 1 analog input and anti-tamper seal IQ 220 Transducer Base only with INCOM Communications and KYZ output 3 foot Category 5 Cable 6 foot Category 5 Cable 10 foot Category 5 Cable IQ220TRAN

IQ 200

General Description
The Cutler-Hammer IQ 200s compact size and exible mounting capabilities make it perfectly suited for machine control panels such as panelboard and switchboard mains and feeders, low voltage metal-enclosed switchgear feeders, motor control centers, and especially for individual load monitoring. The base module can be display mounted, panel mounted, DIN-rail mounted or side mounted. The display ts into a standard 1/4 DIN cutout, and for retrot applications a 100 mm ANSI collar is available.

Retrot Opportunities
Retrot of existing electrical distribution systems with the IQ 200 for load and energy monitoring. Five mounting options makes installation easier.

IQ 200D IQ 210/220 Display Module IQ200D IQ23CABLE IQ26CABLE IQ210CABLE

Ratings
Application to 200 kV, no PTs to 600 V. CT ratios selectable 5 to 8000 A. Single-phase 2- or 3-wire Three-phase 3- or 4-wire.

For more information visit: www.EatonElectrical.com

CA08105001E

IQ Products Electrical Aftermarket Products and Services


March 2006
Aftermarket Solutions, Ref. No. [209]

10-19

IQ 300
One IQ 300 provides an alternative to an assortment of individually wired and mounted ammeters, voltmeters, ammeter and voltmeter switches, wattmeters, varmeters, power factor meters, frequency meters, watthour and demand meters. ANSI C12 Class 10 revenue metering accuracy makes the IQ 300 an ideal choice for circuits where precise energy measurements are required. The IQ 300 can be easily programmed from the faceplate with display and keypad, which features a two-line reverse mode LCD display with LED backlight. Auto scrolling function allows hands-free viewing of all voltages and currents. All measurements can be viewed from the local display. The IQ 300 can also be congured and monitored using PowerPort, free software available on the Eaton Web site, or can be used with PowerNet, the fullfeatured power management system software. Table 10-7. IQ 300 Ordering Information
Description Catalog Number

Current Products (Continued)


IQ 300

1 2 3 4

IQ 310 Complete Meter with Base IQ310 Module, Display, and 14-inch (355.6 mm) Cable no communications, no pulse output IQ 320 Complete Meter with Base Module, Display, and 14-inch (355.6 mm) Cable with INCOM communications and pulse output IQ 330 Complete Meter with Base Module, Display, and 14-inch (355.6 mm) Cable with INCOM communications, pulse output, 2 contact outputs, 2 digital inputs, 1 analog input and anti-tamper seal IQ320

IQ330

5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25

IQ 300

General Description
The Cutler-Hammer IQ 300s thin display and exible mounting capabilities make it perfectly suited for any application where an accurate, multifunction meter is desired such as panelboard and switchboard mains and feeders, motor control centers, and both low voltage and high voltage metal-enclosed switchgear. The base module can be display mounted, panel mounted, DIN-rail mounted or side mounted. The display only requires 1.5 inches behind the panel it is mounted in, including display to base cable.

IQ 330M Complete Meter IQ330M with Base Module, Display, and 14-inch (355.6 mm) Cable with RS-485 Modbus communications, pulse output, 2 contact outputs, 2 digital inputs, 1 analog input and anti-tamper seal IQ 300D Display Module Only 3 feet (.9 m) Long CAT5 Cable 6 feet (1.8 m) Long CAT5 Cable 10 feet (3 m) Long CAT5 Cable IQ300D IQ23CABLE IQ26CABLE IQ210CABLE

CA08105001E

For more information visit: www.EatonElectrical.com

10-20

IQ Products Electrical Aftermarket Products and Services


March 2006

IQ Multipoint Energy Submeter II

Aftermarket Solutions, Ref. No. [210]

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25

Current Products (Continued)


IQ Multipoint Energy Submeter II
Product Description
The Cutler-Hammer IQ Multipoint Energy Submeter II from Eatons electrical business is a low cost multipoint meter a revenue class electronic submetering device that can be mounted in panelboards or switchboards. When mounted in a panelboard or switchboard, the IQ Multipoint Energy Submeter II provides customers with an integrated power distribution and energy metering solution that saves space, reduces installation labor and lowers total cost.

The IQ Multipoint Energy Submeter II is ideal for multi-tenant applications in which property managers are interested in measuring tenant energy usage for the purpose of monthly energy cost allocation. As such, its customers include apartment complex owners, ofce owners, tenant building managers, and meter reading companies. The IQ Multipoint Energy Submeter II can measure any of the following number of circuits:

The IQ Multipoint Energy Submeter II uses highly accurate current sensors to monitor each load. Current sensors can be provided in a number of ratings and are supplied with integral cable and plug-in connector. All current sensors are self-protecting in the event of an open circuit condition under load. The IQ Multipoint Energy Submeter II automatically detects the rating of each current sensor that is connected. The IQ Multipoint Energy Submeter II is UL listed as a Class 1 device.

16 single-phase, two-wire (single-pole). 8 single-phase, three-wire (two-pole). 5 three-phase, four-wire (three-pole).


Ordering Information
The IQ Multipoint Energy Submeter II, current sensors and other accessories can be ordered from Eaton distributors. Refer to the following catalog numbers when ordering. Table 10-8. IQ Multipoint Energy Submeter II and Accessories
Product Description Catalog Number

General Description
The IQ Multipoint Energy Submeter II provides a cost-effective solution for residential or commercial metering installations. Typical installations include:

High-rise buildings. Government institutions. Universities and campuses. Ofce buildings. Medical facilities. Apartment and condominium complexes. Airports. Shopping malls. Industrial parks. Marinas. RV parks. Mixed-use facilities.

Any combination of circuits may be used provided the total number of current sensors does not exceed 16. The meter provides instantaneous (kW), demand and cumulative (kWh) measurements for each load. The unit also provides interval energy data logging, time-of-use energy registers, coincident peak demand storage, and scheduled remote meter reading data in non-volatile memory. Bus voltage is also measured.

IQ Multipoint Energy Submeter II IQMESIIN1 120/208/240 V with INCOM Communications IQ Multipoint Energy Submeter II IQMESIIN2 277/480 V with INCOM Communications IQ Multipoint Energy Submeter II IQMESIIN3 347/600 V with INCOM Communications External CT Current Sensor 5 Amperes for Use with External CTs 50 Ampere Current Sensor 70 Ampere Current Sensor 125 Ampere Current Sensor 200 Ampere Current Sensor 400 Ampere Current Sensor Current Sensor Extension 4 feet (1.2 m) Current Sensor Extension 8 feet (2.4 m) Current Sensor Extension 16 feet (4.8 m) CS005

CS050 CS070 CS125 CS200 CS400 CSET04 CSET08 CSET16

Application Description
The IQ Multipoint Energy Submeter II provides cost-effective and space-saving energy submetering for a wide variety of applications. The IQ Multipoint Energy Submeter II is ideally suited for energy metering of multi-tenant buildings. It can also be used to monitor energy to any load up to 600 volts for energy billing or cost allocation. Built-in communication capabilities enable an IQ Multipoint Energy Submeter II to be networked to a local PC or via modem to a remote master PC or energy service provider.

Stacked Pair of IQ Multipoint Energy Submeter IIs in a Cutler-Hammer Pow-R-Line 3a Panelboard

The IQ Multipoint Energy Submeter II product may be applied and installed in a stacked design. The submeter remains treated as two individual devices. The 16-circuit limit applies for each unit, and both devices may not share a single circuit. By stacking two individual units together, a signicant panel space savings can be accomplished, and a possible 32 circuits can now be available in a single panel design.

For more information visit: www.EatonElectrical.com

CA08105001E

IQ Products Electrical Aftermarket Products and Services


March 2006
Aftermarket Solutions, Ref. No. [211]

10-21

MP-3000 Motor Protection Relay


The MP-3000 motor protection relay provides adaptive overload trip characteristics based on motor temperature when motor RTDs are connected through an optional URTD module. Metering of RTD inputs (individual winding, motor bearing, load and auxiliary temperatures) is also provided. The MP-3000 motor protection relay has two discrete inputs, four Form C (1NO and 1NC) contacts and one 4 to 20 mA analog output. The relay provides maximum user exibility to congure the I/O. All inputs and outputs (except for the trip output) are user-programmable. In addition, the relay has 10 LEDs for the indication of protection on, program mode, monitor mode, view setting mode, history mode, log mode, trip, alarm, auxiliary 1 and auxiliary 2 operation. A test page in the program mode provides display indication of the discrete input states and testing of the output relays, target LEDs and analog circuit. A user-friendly operator interface and display provides quick access to the settings, monitored values, motor history and operational logs. Large LED alphanumeric character display provides easy viewing from any angle in any light. Simple keypad operation provides quick and easy navigation through all settings and stored data. The program mode and emergency override buttons are access restricted via sealing provisions and latched cover. An integrated help function provides an online description display of functions, abbreviations and operations.

Current Products (Continued)


MP-3000 Motor Protection

1 2 3 4 5 6 7 8 9 10 11 12

Optimum Motor Protection


The MP-3000 motor protection relay has been designed for maximum motor operation and protection. It permits running the motor as close to its design limits while protecting it against excessive heating and damaging overload conditions. The MP-3000 eld proven protection algorithms were developed based on motor designs and operating parameters for optimum operation and protection while minimizing nuisance tripping. The MP-3000 motor protection relay utilizes a patented protection algorithm and measurement technique based on proven positive and negative (unbalance) sequence current sampling and true rms calculations.

MP-3000 Motor Protection

General Description
The Cutler-Hammer MP-3000 motor protection relay is a multifunctional microprocessor-based protective relay for the protection of 3-phase ac motors. Though it may be applied to any size motor at any voltage level, it is most commonly applied on medium voltage or larger motors. The MP-3000 relay is a current only device that provides complete and reliable motor protection, monitoring and starting control functions. The MP-3000 motor protection relay is available in either a xed mount, semi-ush case or in a semi-ush quick release drawout case. Both housings are compact and t a standard IQ cutout. The optional quick release drawout case features two-stage contact disconnects and self-shorting CT circuit terminal blocks. A spare self-shorting terminal pair is available for use as relay removal alarm or for continuous motor operation (non-failsafe mode) on relay removal. The optional communication module is externally mounted on the xed mount case and internally mounted in the drawout case. The MP-3000 motor protection relay has three phase and one ground current inputs. Both a 5 ampere and 1 ampere version are available. The ground protection and metering functions can be used with either a zero sequence ground CT or from the residual connection of the phase CTs. The zero sequence ground CT provides greater ground fault sensitivity than the residual connection. The unit is user-programmable for 60 Hz or 50 Hz operation.

Table 10-9. MP-3000 Motor Protection Ordering Information


Description Motor Protection in Fixed Case, 5 ampere CT, Communication Capable with PONI Motor Protection in Drawout Case, 5 ampere CT, No Communication Motor Protection in Drawout Case, 5 ampere CT, with INCOM PONI Motor Protection in Fixed Case, 1 ampere CT, Communication Capable with PONI Motor Protection in Drawout Case, 1 ampere CT, No Communication Motor Protection in Drawout Case, 1 ampere CT, with INCOM PONI Motor Protection Drawout Case Inner Chassis, 5 ampere, CT, No Communication Motor Protection Drawout Case Inner Chassis, 5 ampere, CT, with INCOM PONI Motor Protection Drawout Case Inner Chassis, 1 ampere, CT, No Communication Motor Protection Drawout Case Inner Chassis, 1 ampere, CT, with INCOM PONI Motor Protection Drawout Case Outer Chassis Motor Protection, 5 ampere, URTD, INCOM PONI, Fiber Optic Link Motor Protection, 1 ampere, URTD, INCOM PONI, Fiber Optic Link 5 Meter Fiber Optic Cable for MP-3000/URTD Communication Universal RTD Module Catalog Number MP-3000 MP-3001 MP-3002 MP-3100 MP-3101 MP-3102 MP3001-IC MP3002-IC MP-3101-IC MP3102-IC MP3-OC MP3000VPI MP3100VPI MPFO-5 URTP

13 14 15 16 17 18 19 20 21 22 23 24 25

CA08105001E

For more information visit: www.EatonElectrical.com

10-22

IQ Products Electrical Aftermarket Products and Services


March 2006

FP-5000 Feeder Protection Relay

Aftermarket Solutions, Ref. No. [212]

1 2 3 4 5 6

Current Products (Continued)


FP-5000 Feeder Protection

Application Description
The Cutler-Hammer FP-5000 feeder protection relay provides complete 3-phase and ground overcurrent and voltage protection plus metering in a single, compact drawout case. It may be used as primary protection on feeders, mains and tie circuit breaker applications, and as backup protection for transformers, high voltage lines and differential protection. The relay is most commonly used on medium voltage switchgear applications. The FP-5000 takes full advantage of its microprocessor technology providing the user new freedoms and a wealth of data-gathering features. The relay performs self-checking of all major hardware and rmware protection elements to ensure their operation in the event of a system or component electrical failure or fault. Protection functions are well suited for main and distribution feeder circuit applications. Programmable logic control functions make the FP-5000 relay ideally suited for main-tie-main and main 1/main 2 transfer schemes. The multiple settings groups can be utilized for arc ash mitigation when an alternative setting group, set to have instantaneous elements only is activated using a selector switch and the programmable I/O in the FP-5000. The Zone Interlocking feature can be utilized for bus protection instead of an expensive and complicated bus differential (87B) scheme. The FP-5000 works directly with the Cutler-Hammer Digitrip 3000 and Digitrip MV relays.

Breaker failure logic provides faster remote backup clearing times for stuck breaker operation. The FP-5000 provides trip and close circuit monitoring and alarming features. It continually monitors the complete trip and close circuits for continuity and readiness to trip. Open and close pushbuttons are conveniently located on the front of the relay for local breaker operation. Loss-of-vacuum monitoring is activated when the breaker is open. Residual current is monitored and alarmed if detected. When an electrical fault or disturbance occurs, the FP-5000 begins to store the following in non-volatile memory: Voltage and current sampled data. Calculated values. Status of internal protection functions, logic, contact inputs and outputs.

Feeder Protection FP-5000

7 8 9 10 11

General Description

12 13

14 15 16 17 18 19 20 21 22 23 24 25

Microprocessor-based protection with monitoring and control for medium voltage main and feeder applications. Current, voltage, frequency and power protection for electric power distribution systems. Complete metering of voltage, currents, power, energy, minimum/ maximum and demand functions. Programmable logic control functions for main-tie-main transfer schemes. Trip logs, event logs and waveform capture for better fault analysis and system restoration. Data Logger to provide energy usage proles for better planning, utilization and energy usage. Compact, drawout case design. Meets ANSI, UL and cUL standards. Multiple setting groups. ANSI, IEC and thermal protection curves for greater exibility.

Retrieval and viewing of the data is easy, aiding in the quick analysis and restoration of your electric power system. When the FP-5000 isnt responding to disturbances in the power system, its providing valuable metering information at the relay and remotely. It provides energy usage and demand reading, and can alarm when usage reaches a set value. Power factor measurements can be used for cap bank switching to control kvar demand. Onboard data trending can provide load proles for up to 40 days.

Catalog Numbering System


Table 10-10. FP-5000 Catalog Numbering System

FP5 2 00 - 0 1
Current Range 2 = 5 Amperes 3 = 1 Ampere Control Voltage 0 = 48 125 Vac/dc 1 = 100 240 Vac/dc Communications Protocol 0 = INCOM 1 = Modbus

For more information visit: www.EatonElectrical.com

CA08105001E

IQ Products Electrical Aftermarket Products and Services


March 2006
Aftermarket Solutions, Ref. No. [213]

10-23

DT-3000 MV Trip Unit


The DT-3000 may be applied as the transformer primary protection or as backup to the differential protection. The DT-3000 also has zone selective interlocking to minimize equipment damage resulting from a phase or ground fault in an area where long time and/or short time delay is in use. The integral Dual-Source Power Supply allows the DT-3000 to operate solely from the main CTs during a fault if the normally connected ac voltage is not available, i.e., an electromechanical or electronic self powered relay.

Current Products (Continued)


DT-3000

Electrical Power System Protection


The DT-3000 provides phase and ground protection for most types of medium voltage electrical power distribution systems. Protection curves are similar to those on low voltage power circuit breaker trip units, and provide close coordination with downstream devices, as well as upstream fuse and/or electromagnetic relays. Just one DT-3000 replaces the normal complement of three or four conventional electromagnetic overcurrent relays, an ammeter, a demand ammeter, an ammeter switch and, in some situations, a lockout relay switch (device 86).

1 2 3 4 5 6 7

DT-3000

General Description

Table 10-11. DT-3000 Ordering Information


Description DT-3000 Protective Relay DT-3000 Protective Relay Chicago Version DT-3030 Protective Relay (24 48 Vdc CE Mark Version) DT-3000 Drawout Case Protective Relay DT-3000 Chicago Version Drawout Case Protective Relay DT-3030 Drawout Case Protective Relay (24 48 Vdc CE Mark Version) DT-3000 Protective Relay with 120 Vac Dual-Source Power Supply DT-3000 Protective Relay with 240 Vac Dual-Source Power Supply Catalog Number DT3000 DT3100 DT3030 DT3001 DT3101 DT3031 DT3010 DT3020

Microprocessor-based, 3-phase and ground overcurrent relay. Independent phase and ground measuring circuits and operation. ANSI, IEC and thermal protection curves. Fixed mount or drawout design. Dual-source power supply option for ac control power applications.

8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25

The Cutler-Hammer Digitrip 3000 Trip Unit (DT-3000) is a multifunction, microprocessor-based overcurrent trip unit designed for both ANSI and IEC applications. The DT-3000 design provides true rms sensing design of each phase and ground current. It can be power from either ac or dc control power. The DT-3000 can be used for any application where instantaneous and/or time overcurrent protection is required.

CA08105001E

For more information visit: www.EatonElectrical.com

10-24

IQ Products Electrical Aftermarket Products and Services


March 2006

Accessories

Aftermarket Solutions, Ref. No. [214]

1 2 3 4 5 6

Accessories
IQ Flange

IQ DC Power Supply

IQ Cable

IQ Cable IQ Flange

7 8 9 10 11 12

For applications where extra door mounting space is required, a angemounting unit is available. The CutlerHammer IQ Flange provides an extra 2.5 inches of clearance for the device. Table 10-12. IQ Flange Ordering Information
Description Catalog Number

For applications where remote mounting of the power supply is required, an extension cable is available.
IQ DC Power Supply

The IQ DC Power Supply is a dc to ac inverter module intended for use where dc power is available, but some ac is required. The unit will operate an MP-3000 or other ac powered IQ devices requiring no more than 75 VA of power at any power factor. Table 10-13. IQ DC Power Supply Ordering Information
Description IQ DC Power Supply Catalog Number IQDCPS

Two types of cable are available. The rst (catalog number IQCABLE) is for the obsolete IQ Data, Generator, and Data Plus II. The second (catalog number IQA45CABLE) is for the IQ Analyzer and IQ DP-4000. Table 10-14. IQ Cable Ordering Information
Description 36-inch Extension Cable IQ Data, Generator, Data Plus II 45-inch Extension Cable IQ Analyzer/IQ DP-4000 Catalog Number IQCABLE IQA45CABLE

IQ Flange Option, to Provide IQFLANGE Extra Clearance when Mounting

13 14 15 16 17 18 19 20 21 22 23 24 25
For more information visit: www.EatonElectrical.com CA08105001E

IQ Products Electrical Aftermarket Products and Services


March 2006
Aftermarket Solutions, Ref. No. [215]

10-25

Accessories

Accessories (Continued)
IQ Floor-Mounted Enclosure

Addressable Relay II

Power Modules
Eaton and Westinghouse have produced a number of different meters dating back to the 1980s. Many of these meters used and continue to use power modules to provide voltage sensing isolation and control power to the meter. Power modules are available to power the meter directly from the voltage source being sensed or for separate control power input. Renewal part power modules are available for the meters shown in Table 10-17 below. Table 10-17. Power Modules Ordering Information
Description Used with Meter Style Number 2D78533G03 2D78533G04 Power Module Catalog Number DATAGENPM

1 2 3 4 5 6 7 8 9

Addressable Relay II

Two 10-Inch wide Enclosures (Shown with Optional 10-Inch High Bus Compartment)

The Addressable Relay II has two status inputs and a Form C contact output. Input rating: 48 120 Vac, 48 125 Vdc. Output contact rating: 10 A at 277 Vac, 10 A at 30 Vdc. Features include a communications watchdog and relay pulse. Baud rate is selectable. Table 10-16. Addressable Relay II Ordering Information
Description Addressable Relay II Catalog Number ARII

Type 1
Standard AMPGARD structure construction, painted ASA-61. To be used as a lineup extension for mounting IQ products. Each 10-inch wide section comes with (two) doors with worksin-a-drawer drawout panel. Each door has (three) standard IQ cutouts with device panels and can be supplied with or without IQ devices. Table 10-15. IQ Floor-Mounted Enclosure Ordering Information
Description 10-inch W x 30-inch D x 90-inch H (Bus Compartment Optional) Style Number 2147A95G35

Old IQ Data and IQ Generator Power Module

Old IQ Data 2D78522G01 Plus II SelfPowered 3-Phase Power Module Old IQ Data Plus II Separate Source 110 to 240 Vac Power Module Old IQ DP-4000 and IQ Analyzer Self-Powered 3-Phase Power Module 2D78522G02

IQDP3PPM

10
IQDPSSPM

11 12

2D82302GXX IQA3PPM 4D13110GXX

13 14 15 16 17

Old IQ DP-4000 2D82302GXX IQASSPM and IQ Analyzer 4D13110GXX Separate Source 110 to 240 Vac or 110 to 250 Vdc Power Module New IQ DP-4000 and IQ Analyzer Self-Powered 3-Phase Power Module New IQ DP-4000 and IQ Analyzer 24/48 Vdc Power Module 66D2045GXX IQM3PPM 66D2040GXX

66D2045GXX IQMDCPM 66D2040GXX

18 19 20 21 22 23 24 25

New IQ DP-4000 66D2045GXX IQMSSPM and IQ Analyzer 66D2040GXX Separate Source 110 to 240 Vac or 110 to 250 Vdc Power Module

The adjacent power modules will work with each basic meter style, regardless of the last two digits of the meter style number.

CA08105001E

For more information visit: www.EatonElectrical.com

10-26

IQ Products Electrical Aftermarket Products and Services


March 2006

IQ 2000, IQ Analyzer 6000/6200 and RTD Module

Aftermarket Solutions, Ref. No. [216]

1 2 3 4 5 6 7

Replacement Capabilities Discontinued Product Recommended Replacement


IQ 2000 IQ Analyzer 6000/6200 RTD Modules

IQ 2000 Model A

IQ Analyzer 6000/6200

Universal RTD Module

8 9 10 11 12
IQ 2000 Model B

13 14 15 16 17 18 19 20 21 22 23 24 25

The Cutler-Hammer IQ Analyzer 6000/ 6200 is a complete solution for users who want to monitor all aspects of their electrical distribution system. It provides extensive metering, power quality analysis, remote input monitoring, control relaying, analog input/outputs and communications capability. All programming can be done through the faceplate or through the communications option. Its online Help Pushbutton feature displays information on device operation, programming and troubleshooting.

Recommended Replacement:
The RTD Modules for the IQ 2000 have been discontinued. Now available is the new Universal RTD Module that replaces all of the RTD modules for the Model A and B IQ 2000 units, as well as the IQ 1000, IQ 1000 II and all current IQ metering and protection products. Table 10-18. Universal RTD Ordering Information
Description Universal Module Catalog Number URTD

Recommended Replacement:
Production of IQ 2000 devices has been discontinued. The IQ 2000 can be replaced with the MP-3000 electronic motor protective relay and the IQ DP-4000 electronic meter. The MP-3000 provides motor current protective relaying, while the IQ DP-4000 provides complete electrical metering and voltage protective alarming functions. For specic application consideration, contact your local Eaton Field Sales ofce.

Features and Benets


All information accessible through communications port. Quality true rms readings through 50th harmonic. Meets ANSI C12.16 class 10 revenue metering spec. Accurate readings for non-sinusoidal waveforms with up to 3.0 crest factor. Screens display auto ranging units, kilo units, mega units as needed. 10 digit energy readings. Displays multiple parameters at the same time. Programmable custom screens.

The IQ Analyzer Model 6200 with waveform display at the device and sub-cycle voltage disturbance capture provides the capability to monitor a wide range of harmonic parameters. These include harmonic voltage, current magnitudes and phase angles, as well as system disturbances such as transient voltage disturbances and sub-cycle voltage interruptions. This unit is also available in a portable version.

Recommended Replacement:
New IQ Analyzer 6400/6600.

For more information visit: www.EatonElectrical.com

CA08105001E

IQ Products Electrical Aftermarket Products and Services


March 2006
Aftermarket Solutions, Ref. No. [217]

10-27

IQ Data Plus/II, IQ 1000/II, IQ Data and IQ Generator

Replacement Capabilities (Continued) Discontinued Product Recommended Replacement (Continued)


IQ Data Plus and IQ Data Plus II IQ Data IQ Generator

1 2 3 4 5 6 7

IQ Data Plus II

IQ Data

IQ Generator

The Cutler-Hammer IQ Data Plus was discontinued in 1989 and was replaced by the IQ Data Plus II. The IQ Data Plus II was discontinued in 1998.

Recommended Replacement:
IQ DP-4000

The Cutler-Hammer IQ Data provides simultaneous current and voltage metering. In one compact, standard package, this device provides an alternative to individually mounted and wired ammeters, voltmeters, ammeter and voltmeter switches.

Features and Benets

The Cutler-Hammer IQ Generator provides simultaneous current and voltage metering. In addition, the IQ Generator monitors frequency. This device provides an alternative to individually mounted and wired ammeters, voltmeters, ammeter and voltmeter switches and frequency meters.

8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25

IQ 1000 and IQ 1000 II

IQ 1000 II

Recommended Replacement:
Both the IQ 1000 and the IQ 1000 II have been discontinued and replaced by the MP-3000 for complete motor protection. A detailed application note (MP3K01R4.PDF) describing replacement of the IQ 1000 II with an MP-3000 is available at www.EatonElectrical.com.

Space savings in structure replaces ammeter, voltmeter, selector switches and frequency meter (IQ Generator). Standardization of design one door-mounted device. Direct voltage input up to 600 V No additional Potential Transformers (PTs) required. User friendly eld settable DIP switches. Standard model derives power from separate source 120/240 Vac supply. Only two style numbers. No need to stock multiple units for different Current Transformers (CT) and PT ratios. Interface capability to computer network for data collection, storage and/or printout via IMPACC. Membrane faceplate, designed and tested to perform in a harsh industrial environment (Type 3R, 12). Retains preset parameters through power failure with use of eld settable DIP switches (no batteries).
Catalog Number IQDATA IQDATAPM

Features and Benets

Space savings in structure replaces ammeter, voltmeter, selector switches and frequency meter (IQ Generator). Standardization of design one door-mounted device. Direct voltage input up to 600 V No additional PTs required. User-friendly eld settable DIP switches. Standard model derives power from separate source 120/240 Vac supply. Only two style numbers. No need to stock multiple units for different CT and PT ratios. Interface capability to computer network for data collection, storage and/or printout via IMPACC. Membrane faceplate, designed and tested to perform in harsh industrial environment (Type 3R, 12). Retains preset parameters through power failure with use of eld settable DIP switches (no batteries).
Catalog Number IQGEN IQGENPM

Table 10-20. IQ Generator


Description Basic Metering Basic Metering with 3-Phase Power Module

Table 10-19. IQ Data


Description Basic Metering Basic Metering with 3-Phase Power Module

Recommended Replacement:
IQ 300.
CA08105001E For more information visit: www.EatonElectrical.com

Recommended Replacement:
IQ 300.

10-28

IQ Products Electrical Aftermarket Products and Services


March 2006
Aftermarket Solutions, Ref. No. [218]

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25

Further Information
Publication Number Description

Metering Devices
TD02600001E TD.17.02B.T.E TD.17.03A.T.E TD.17.31.T.E TD.17.06A.T.E TD.17.07.T.E TD02601004E TD17C01TE TD17C03TE TD.17.08A.T.E TD.17.08A.T.E TD02601002E Selection Chart IQ Analyzer IQ DP-4000 IQ 300 IQ 200 IQ Sentinels IQ Multipoint Energy Submeter II Portable IQ Analyzer Optional Clamp-on CTs IQ DP-4000 I/O Module IQ Analyzer/IQ DP-4000 Auxiliary Power Supply Current Transformers Selection Chart Digitrip 3000 Overcurrent Relay MP-3000 Motor Protection Relay FP-5000 Feeder Relay Dual-Source Power Supply Digitrip 3000 Optional Drawout Case Universal RTD Module IQ DC Power Supply

Protective Relays
TD02600001E TD.17.10.T.E TD.17.11.T.E TD.17.30.T.E TD.17.12.T.E TD.17.13.T.E TD.17.14.T.E TD.17.08A.T.E

Pricing Information
IQ Products
Vista/VISTALINE Discount Symbol C10-S24.

DT-3000
Vista/VISTALINE Discount Symbol MV-3.
CSA is a registered trademark of Canadian Standards Association. Cutler-Hammer is a federally registered trademark of Eaton Corporation. Modbus is a registered trademark of Modicon, a division of Schneider Electric Industries SA. NEMA is a registered trademark and service mark of the National Electrical Manufacturers Association. UL and cUL are federally registered trademarks of Underwriters Laboratories Inc.

For more information visit: www.EatonElectrical.com

CA08105001E

NOTICE
These les are the same as the last printed version of the catalog dated March 2006. For the most up-to-date information, install the Automatic Tab Updater (ATU) by visiting www.gathermydata.com/install or visit our web site at www.eaton.com/electrical.
Click HERE to Continue

You might also like