You are on page 1of 16

Huawei Partner IT Product Manual

Storage Section

HUAWEI TECHNOLOGIES CO., LTD.

Huawei storage products panorama

The channel storage products


N8500 Clustered NAS CSS Distributed Storage Big Data Storage N9000
Full symmetrix distributed architecture 3~288 nodes, up to 40PB capacity SPECsfs2008 5M+ OPS Dynamic storage tiering 10GE/Infiniband high-speed interconnect

UDS Massive Storage

Big Data & Cloud Storage

Active-Active cluster architecture File and block interface 2~24 nodes, up to 15PB capacity SPECsfs2008 3M+ OPS Rich features for data management

Open hardware and distributed file system architecture Posix/NFS/CIFS/JDBC/ODBC interface Multi-GE interconnect

Amazon S3 compliance EB level scalability High density design, 2PB+ in 1 rack

HDP3500E

VTL6900

Dorado2100 G2

Dorado5100

VIS6600T

Data Protection

Integrate with NBU DB, file and OS data protection VM data protection

PB level scalability Cluster architecture Inline dedup and postprocessing dedup

Disk Storage

Up to 400K IOPS of SPC-1 Access latency low to 500s Four-level data protection

Up to 600K IOPS of SPC-1 Access latency low to 500s Four-level data protection

2~8 nodes, Scale-out Virtual Storage

S2200T

S2600T/S5500T/S5600T/S5800T

S6800T

HVS85T/HVS88T

Disk Storage
Dual controllers 4GB cache 204 disks Unified Storage, supports both block and file applications Up to 192GB cache Up to 1,440 disks

Up to 384GB cache Up to 1440 disks Up to 250K IOPS of SPC-1

2 ~ 16 controllers Up to 3TB cache Up to 3,216 disks 0~5s RPO

Storage Management Software

Data Replication Software


Management Console InfraControl HyperSnap HyperClone HyperCopy HyperReplication

Storage Software

SmartQoS SmartMotion SmartTier

SmartCache SmartThin SmartX Insight

UltrPath UltraVR UltraAPM

Huawei storage specications at a glance

SAN / Unied Storage Specications


Model Architecture
Single/Dualcontroller Dualcontroller Dualcontroller Dualcontroller Dualcontroller Dualcontroller

IOPS

Number of le engine
NA

OPS

Cache

Maximum Disks per number of enclosure drives


204 12

drive type
SAS/NL SAS/ SATA SSD/SAS/NL SAS/SATA SSD/SAS/NL SAS/SATA SSD/FC/SAS/ NL SAS/SATA SSD/FC/SAS/ NL SAS/SATA SSD/FC/SAS/ NL SAS/SATA

Host port
8 Gbps FC or 1 Gbps iSCSI 8Gbps FC, 1Gbps iSCSI, 10Gbps Iscsi(TOE)

Backend port
6Gb SAS

backend port(per controller)


1

S2200T

18,000

NA

2/4

S2600T

40,266 *

100,000 8/16

276

12/24

6Gb SAS

S5500T

60,242 *

2/4

200,000 8/16/32

528

12/24

6Gb SAS 4Gb FC/6Gb SAS 4Gb FC/6Gb SAS 4Gb FC/6Gb SAS

S5600T

102,471 *

2/4/6

300,000 24/48

1152

24

S5800T

130,000

2/4/6/8

400,000 96/192

1440

24

8Gbps FC, 1Gbps iSCSI, 10Gbps iSCSI(TOE), 10Gbps FCoE

4/4~16

4/4~20

S6800T

250,388 *

NA

NA

192/384 1440

24

4/4~20

*: SPC-1 Result

Huawei storage specications at a glance

The main SAN / Unied Storage


HUAWEI BAND7 BAND6 BAND5 BAND4 BAND3
300K~500k 200K~300k S6800T S5800T

EMC
VMAXe VNX 7500 XIV

IBM

NetApp
FAS6200 FAS3270 E7900 FAS3240 E7900 FAS3210 E5400 FAS2240 E2600 FAS2040

HP

Dell
Compellent

HDS

V7000U

F400 P6000 F200 P6000 P6000

Compellent AMS2500

100K~200K

S5600T

VNX 5700

DS5300

PS6010

50K~100K

S5500T

VNX 5500

DS5100

PS6000

AMS2300

25K~50K

S2600T

VNX 5300 VNX 5100 VNXe3300 VNXe3100

DS5020

P4000

PS4000

AMS2100

BAND2

5K~25K

S2200T

DS3500

P2000

MD3600 MD3200

Huawei storage specications at a glance

The main high-end cluster NAS


PRICE(USD) HUAWEI EMC Isilon IBM NetApp FAS

BAND9 BAND8 BAND7

>1M N8500 500K~1M

300K~500K

N8500

S200 x400

N7900 SoNAS

FAS6280 FAS6080

BAND6

200K~300K

N8500

S200 x400

N6060 SoNAS

FAS6240 FAS6040

Huawei storage specications at a glance

All-solid-state storage & High-end NAS specications


Model Architecture SPC-1 IOPS Number of host ports Cache Maximum number of drives or capacity Disks per enclosure Drive Host port
8Gbps FC/ 10GE (iSCSI) /40Gb IB 8Gbps FC/ 10GE (iSCSI)

Maximum Backend number of backend port port

Dorado2100 G2

Dualcontroller

8Gb FC : 16 10 Gb iSCSI: 8 48 40Gb IB:4

100

25

SLC: 100GB/200GB; eMLC: 200GB/400GB SLC: 100GB/200GB; eMLC: 200GB/400GB

6Gb SAS

16

Dorado5100

Dualcontroller

600,052

8Gb FC : 40 10GE : 20

96

96

24

6Gb SAS

20

N8500

2~24 nodes

3,064,602*

4~16/node

16~192 GB/node

15PB

12/24

FC/SSD/SAS/ NL_SAS/SATA

10GE/GE

4Gb FC/ 6Gb SAS

NA

#: release later *: SPECsfs2008_nfs.v3 Result

Huawei storage specications at a glance

List of software function


software
Thin provisioning

Intended use
storage space is allocated based on the actual amount of written data , improve resource utilization Using SSD and hotspot identification technology, the hot data is copied from the HDD to the SSD to enhance the performance Based on the point-in-time data copy, provides data protection for local failure

S2200T

S2600T/5500T/ 5600T/5800T
HyperThin

S6800T
HyperThin

N8500
HyperThin

Dorado
HyperThin

SSD data cache

SmartCache HyperImage(Block) Snapshot(File) HyperCopy HyperClone HyperMirror (Synchronous) HyperMirror (Synchronous) HyperMirror (Asynchronous) (Block) File Engine Replication(File) DiskGuard

SmartCache

SmartCache

Snapshot

HyperImage HyperCopy

HyperImage HyperCopy HyerClone HyperMirror (Synchronous)

HyperImage HyperCopy HyperClone HyperMirror (Synchronous) HyperMirror (Asynchronous) (Block) File Engine Replication(File)

HyperImage

The heterogeneous Data migration between heterogeneous devices volume data copy Volume cloning Synchronous remote replication provide multiple real-time copies of data volumes, can be used for the production, testing Provide data protection from power outages and disasters, to ensure zero data loss

HyperMirror (Synchronous)

Asynchronous remote replication

Provide a long distance data protection from power outages and disasters; can accept some data loss

HyperMirror (Asynchronous)

HyperMirror (Asynchronous)

HyperMirror (Asynchronous)

Host Disk Protection data protection for application consistency Storage device management NAS protocols Multipath Storage Resource Management VMware VAAI

Protect the host disk partition, the operating system and files

DiskGuard

DiskGuard

Require the data consistency of application program UltraAPM Provide configuration, monitoring and management ISM of storage device Require standard protocol when hosts access NAS storage Provide path selection, path switching when hosts access SAN storage Provide the end-to-end management of the storage from the host / virtual machine, network to storage device Compatible with vSphere VAAI to enhance the storage efficiency of virtual machine Compatible with Vmware SRM interface, realize disaster recovery of virtual machine Compatible with SMI-S standard protocols, provides a standard interface for third-party management system UltraPath

UltraAPM

UltraAPM

ISM CIFS/NFS/FTP/Http UltraPath

ISM

ISM CIFS/NFS/FTP/Http

ISM

UltraPath

UltraPath

InfraControl

InfraControl

InfraControl

InfraControl

Support 5.1

Support 5.1 SRM 5.0; SRM 5.0 Update 1

Support 5.1 SRM 5.0; SRM 5.0 Update 1 SMI-S 1.4

NA

NA

Vmware SRM

SMI-S CTP

SMI-S 1.4

Product description

Starter storage S2200T


Target Market
SMBs and remote /branch offices Distributed DAS implementations Large enterprise and corporate distributed sites dual controllers single controller Government and education Current FC SAN Implementations Customers with high-bandwidth applications that require strong sequential performance Large file storage Video capture/streaming SharePoint & CAD Backup-to-disk implementations

Key selling points:


Entry-level price, 816TB Value Low-end market leader with feature-rich software and meet the full different demand.

Product description

S2200T Controller Enclosure


Front view of the controller enclosure (single controller and dual controllers)
Controller enclosure
Houses 12x3.5-inch hard disks Supports mainstream SAS, NL SAS, and SATA disks Provides four 2+2 redundant coffer disks in the first four slots

Rear view of the controller enclosure (dual controllers)

Rear view of the controller enclosure (single controller)

Controller and disk integration (dual controller)


Provides management network ports and serial ports. Carries one onboard 4x6 Gbit/s SAS port. Supports one expansion I/O module. Carries four onboard GE ports.

Power module
1+1 redundant Provides a conversion efficiency of 92%. (The conversion efficiency of golden power supplies is 88%.)

Fan/BBU
Intelligent fan speed control BBUs are built in the system to provide power failure protection

Controller and disk integration


Provides management network ports and serial ports. Carries one onboard 4x6 Gbit/s SAS port. Carries four onboard GE ports.

Product description

Unied Storage: T Series


SAN application server NAS application server

CIFS/NFS FC/iSCSI File engine components

Key selling points:


File & block fusion, network simplifies Innovative Smart Series software, according To the need of storage resources

Block engine components Disks group components

Product description

Key selling points


Customer problems Product features
Unified storage (files and data blocks) Scalable Flexible Redundant modules provide highly reliability Hot swap technology Designed to provide "five nines" availability A wealth of data protection features Smartcache Policy-based tiering Automated tiering The unified support: files, data blocks Storage optimization technology, including data blocks virtual file deduplication and virtual provisioning Tiered storage (SSD, SAS, NL-SAS) Value-added software

Business Impact
Structured and unstructured data coexist Integration reduces the total cost of ownership Large capacity to meet the rapid data growth

Rapid data growth

Meet stringent SLA requirements

To achieve the best level of service High performance access Always available (best state) Data is protected Improve the performance of reading data Easy to manage Automation efficiency

The complexity of the storage tiering

Management costs

Cost-effective Efficient storage utilization Reduce management costs Cost-effective warranty options

Product description

T Series components introduction: File Engine


The file engine of a T series unified storage system is developed on the Pangea V1R3 hardware platform. It is a 4 U independent engine and resembles the Pangea V1R1 hardware platform (S5500T/S5600T/S6800T controller enclosure). Each controller in the independent engine is a node of the file engine, that is, every engine provides two nodes.

Controller File engine


One controller is one node.

Interface module File Engine S2600T/ S5500T One Intel Xeon E5504 2.0 GHz 16GB S5600T/ S5800T One Intel Xeon E5645 2.4 GHz 24GB
Each node has six I/O module slots. Each node has a GE card for heartbeat communication. Each node has an 8 Gbit/s Fiber Channel adapter for array connection. Each node has a maximum of four GE or 10GE adapters for NAS host interfaces.

CPU

Memory

Product description

T Series components introduction: S2600T Block Engine


3.5-inch controller enclosure
Houses 12x3.5-inch hard disks Supports mainstream SAS disks, SATA disks, and SSDs Provides four 2+2 redundant coffer disks in the first four slots

Power module
Achieves 1+1 redundancy Provides a conversion efficiency of 92%. (The conversion efficiency of golden power supplies is 88%.)

Controller module
Provides management network ports and serial ports Carries two onboard 4x6 Gbit/s SAS ports Supports one expansion I/O module Carries four onboard GE ports

Fan/BBU
Fan speed is intelligently controlled BBUs are built in the system to provide power failure protection

Product description

T Series components introduction: S5500T Block Engine


2.5-inch controller enclosure:
Houses twenty-four 2.5-inch hard disks Supports mainstream SAS disks, NL SAS disks, and SSDs Provides four 2+2 redundant coffer disks in the first four slots Independently powers on or off each hard disk

3.5-inch controller enclosure


Houses 12x3.5-inch hard disks Supports mainstream SAS disks, NL SAS disks, and SSDs Provides four 2+2 redundant coffer disks in the first four slots Independently powers on or off each hard disk

Controller module
Provides management network ports and serial ports Carries two onboard 4x6 Gbit/s SAS ports Supports one expansion I/O module Carries four onboard 8 Gbit/s Fiber Channel ports

Fan/BBU
Fans are in 3+1 redundancy. (The system can tolerate the failure of one fan.) Fan speed is intelligently controlled BBUs are built in the system to provide power failure protection

Power module
Achieves 1+1 redundancy Provides a conversion efficiency of 92%. (The conversion efficiency of golden power supplies is 88%.)

Product description

T Series components introduction: S5600T/S5800T Block Engine


Controller module
Dual controllers Automatic CPU frequency control System power-off button

BBU
2+2 redundancy DC/AC power failure protection

Interface module
12 I/O module slots Up to 1440 hard disks Hot-swappable I/O modules Diversified interface types: 8 Gbit/s Fiber Channel, 4 Gbit/s Fiber Channel, 4x6 Gbit/s SAS, GE/10GE

Fan
5+1 redundancy (the failure of one fan is tolerable.) Intelligent fan speed control

Power module Management module


1+1 redundancy Hot-swappable Dual power planes (2+2 redundancy) Provides a conversion efficiency of 92%. (The conversion efficiency of golden power supplies is 88%.)

Product description

SAN S6800T

Key selling points:


Highly reliable architecture designed to ensure that the customer's business system is secure High-end quality, mid-range price

Product description

S6800T Block Engine


Control module
Two controllers CPU frequency control, reducing power consumption System power-off button

BBU module
2+2 redundancy. Supports DC/AC power failure protection

Interface module
Provides 12 I/O modules slots Supports up to 1,440 hard disks Supports hot-swappable interface cards Supports various types of interfaces cards: 8 Gbit/s FC, 4 Gbit/s FC, 4 x 6 Gbit/s SAS, and GE/10GE

Fan module
5+1 redundancy of fans (Faults on one fan do not affect the normal running of the system.) Intelligent fan speed adjustment

Power supply module Management module


1+1 redundancy Supports hot swap Dual plane power supply (2+2 redundancy) The transfer efficiency is up to 92% that is higher than that (88%) of gold medal power supply

Product description

N8500
OceanStor N8500 cluster NAS storage system is an industry-leading, unified storage platform for high-end applications, with high performance, high scalability, high reliability, high efficient data management features.

Key selling points:


1st Leading performance: SPEC 3,064,602 OPS, 2 times to the 2nd No single point failure, high reliability design 15PB exible space, hundred billion files

N8500

Product description

N8500 Hardware Infrastructure


The N8500 is based on the separation of the clustered NAS file engine and the storage unit. The engine is either directly connected to the storage unit or cascaded by using the FC switch Suggested storage unit model: S5500T, S5600T, S5800T, S6800T

Rack GE switch unit (optional) FC switch unit (optional) Engine unit Storage unit

1Clustered NAS File Engine 2Fabric Cable 3FC Switch unit 4Storage unit controller 5Storage unit disk enclosure

10

Product description

Direct connection (two nodes)


Two heartbeat links
FC port GE port Heartbeat port

N8500 Engine

Storage unit

Product description

Switch connection (six nodes)


Two heartbeat switches Two heartbeat links

FC switches

FC port GE port Heartbeat port

Storage unit

11

Product description

N8500 NAS File Engine


Control module
Two controllers Mainstream server platform Automatic frequency adjustment, reducing power consumption System power-off button

BBU module apron


2+2 redundancy DC/AC power failure protection

Fan module
Fan 5+1 redundancy Low power consumption for heat dissipation Granular fan speed control

Interface module
By default, each node provides four GE service interfaces, four 8 Gbit/s FC back-end storage interfaces, and two GE heartbeat interfaces Each node provides three PCE2.0 8x interface card slots for the expansion of GE/10GE service interface card or 8 Gbit/s FC back-end storage interface card All the interface cards support hot swapping

Local system module


Embedded reliable SSD as the local system disk Each system module provides an independent management port. Each system module provides a serial port for software debugging

Power module
2+2 redundancy 92% power conversion efficiency

Product description

Storage Unit Controller with Disks: S5500T Block Engine


2.5-inch disk enclosure
24 x 2.5-inch hard disks Support mainstream disks, such as SAS, SATA, and SSD The first four disks are coffer disks, forming 2+2 redundancy Each disk can be independently powered on/off

3.5-inch disk enclosure


12 x 3.5-inch disks Support mainstream disks, such as SAS, SATA, and SSD The first four disks are coffer disks, forming 2+2 redundancy Each disk can be independently powered on/off

Control module integrating controller and disk


Mainstream desktop CPU platform Provides management network ports and serial ports. Two integrated 6 Gbit/s SAS interfaces. Supports 1 interface module Four integrated 8 Gbit/s FC interfaces

Fan module/BBU module


Fan 3+1 redundancy Delicate fan speed control Embedded BBU to protect data when a power-off occurs

Power module
1+1 redundancy 92% power conversion efficiency

12

Product description

Storage Unit Controller without Disks: S5600T/S5800T/S6800T Block Engine


Control module
Two controllers Mainstream server platform Automatic frequency adjustment, reducing power consumption System power-off button

BBU module
2+2 redundancy DC/AC power failure protection

Interface module
12 interface card slots A maximum of 1440 hard disks All the interface cards support hot swapping Various interface types, such as 8 Gbit/s FC, 4 Gbit/s FC, 6 Gbit/s SAS, GE, and 10GE

Fan module
Fan 5+1 redundancy Low power consumption for heat dissipation. Granular fan speed control

Management module
2+2 redundancy Hot swap Embedded reliable SSD as the system coffer

Power module
2+2 redundancy 92% power conversion efficiency

Product description

All-solid state storage Dorado


Huawei OceanStor Dorado series are high-performance all-solid-state SAN for enterprises, with the advanced cache management and I / O scheduling algorithm, based on the design of all-solid-state storage system architecture, provide users performance experience, to meet the needs of large database, high-performance computing, VDI and other different applications of high-performance storage.

Dorado2100 G2

Dorado5100

13

Product description

Dorado2100 G2
Key selling points:
600K IOPS, Microsecond-level access latency, providing ultra high efficiency. Fully redundant architecture, Active/Active mode, enabling services to always remain online.

Superior performance
Dorado2100 G2 provides up to 600K IOPS, equivalent in performance to the traditional array with 750 pcs 15K rpm SAS hard drives. Access time: access latency is as low as 500 s, only 5% of the traditional array delay.

Green energy-saving
Low power consumption: Typical power consumption of the system is less than 110W, compared to traditional arrays with the same performance, energy saves up to 90%.

Stable and reliable


Proprietary four level data protection architecture eliminate single point failure, keep business continuing

Product description

Dorado 5100
Key selling points:
1M IOPS, Microsecond-level access latency, providing ultra high efficiency. Fully redundant architecture, Active/Active mode, enabling services to always remain online. Superior performance
SPC-1 IOPS: Dorado5100 provides up to 600,052 SPC-1 IOPS , equivalent in performance to the traditional array with 2000 15K rpm SAS hard drives. Access time: access latency is as low as 500 s, only 5% of the traditional array delay.

Green energy-saving
Low power consumption: Typical power consumption of the system is less than 110W, compared to traditional arrays with the same performance, energy saves up to 90%.

Stable and reliable


Proprietary four level data protection architecture eliminate single point failure, keep business continuing

14

Copyright Huawei Technologies Co., Ltd. 2013. All rights reserved. No part of this document may be reproduced or transmitted in any form or by any means without prior written consent of Huawei Technologies Co., Ltd. Trademark Notice , HUAWEI, and are trademarks or registered trademarks of Huawei Technologies Co., Ltd.

Other trademarks, product, service and company names mentioned are the property of their respective owners. General Disclaimer
The information in this document may contain predictive statements including, without limitation, statements regarding the future financial and operating results, future product portfolio, new technology, etc. There are a number of factors that could cause actual results and developments to differ materially from those expressed or implied in the predictive statements. Therefore, such information is provided for reference purpose only and constitutes neither an offer nor an acceptance. Huawei may change the information at any time without notice.

HUAWEI TECHNOLOGIES CO., LTD. Huawei Industrial Base Bantian Longgang Shenzhen 518129, P.R. China Tel: +86-755-28780808 Version No.: M3-035262-20130316-C-4.0 www.huawei.com

You might also like