pvSpot REPORT Period type: Period value: Summarization type: Issued: Character encoding: Site: Coordinates (lat, lon):

month Apr 2014 day 09 Apr 2014 17:35 CET (GMT +0100) utf-8

51.998295, 4.374372

PV system: Name: DEMO Delft University of Technology, Netherlands Installed power: 12.24 kWp PV modules: c_Si Installation: building integrated Mounting: fixed mounting, one angle Azimuth/inclination: 180/26 User defined inverter: Euro eff.: 97.5% User defined DC losses: specified in detail User defined AC losses: -0.5% Degradation of PV modules: -0.3%

Service provider: GeoModel Solar s.r.o., Pionierska 15, 83102 Bratislava, Slovakia; Company ID: 45 354 766, VAT Number: Database description: This report is based on SolarGIS v1.8 high-resolution weather database operated by GeoModel Solar s.r.o Disclaimer and legal information: Considering the uncertainty of data and calculations, GeoModel Solar s.r.o. cannot take full guarantee of th Data columns: E_low E_best E_high Enabled Gti Ghi TEMP Expected pv electricity production - low estimation [kWh] Expected pv electricity production - best estimation [kWh] Expected pv electricity production - high estimation [kWh] 0: out of operation day set by user, 1: operational day Global tilted irradiation [kWh/m2] Global horizontal irradiation [kWh/m2] Average diurnal (24 hour) air temperature at 2 m [deg. C]

This report is copyright to 2014 GeoModel Solar s.r.o., all rights reserved. SolarGIS is a registered trade mark of GeoModel Solar

ovakia; Company ID: 45 354 766, VAT Number: SK2022962766; Registration: Business register, District Court Bratislava I, Section Sro, File 62765/B her database operated by GeoModel Solar s.r.o. The PV simulation software is designed to work with 15-minute time series of solar radiation and air tem Model Solar s.r.o. cannot take full guarantee of the accuracy of estimates. The maximum possible has been done for the assessment of weather paramete

IS is a registered trade mark of GeoModel Solar s.r.o.

ct Court Bratislava I, Section Sro, File 62765/B 5-minute time series of solar radiation and air temperature to represent the non-linear nature of PV power generation. Global horizontal and direct normal een done for the assessment of weather parameters based on the best available data, software and knowledge. GeoModel Solar s.r.o. shall not be liable

wer generation. Global horizontal and direct normal irradiance are calculated from Meteosat MSG satellite data, ECMWF aerosols and water vapour data. owledge. GeoModel Solar s.r.o. shall not be liable for any direct, incidental, consequential, indirect or punitive damages arising or alleged to have arisen o

e data, ECMWF aerosols and water vapour data. Air temperature at 2 m is calculated from NOAA NCEP GFS data. Both solar and temperature data are unitive damages arising or alleged to have arisen out of use of the provided report.

P GFS data. Both solar and temperature data are enhanced by high resolution terrain to the spatial resolution of approx. 80 metres. More information can

olution of approx. 80 metres. More information can be found at: http://solargis.info/doc/pvspot/.

Date E_low E_best E_high Enabled Gti 2014-04-01 49 55 61 1 2014-04-02 38 46 53 1 2014-04-03 36 43 51 1 2014-04-04 6 8 11 1 2014-04-05 49 56 63 1 2014-04-06 9 13 20 1 2014-04-07 21 30 41 1 2014-04-08 30 41 53 1

Ghi 5.50 4.53 4.31 0.92 5.60 1.40 3.05 3.98 4.45 3.87 3.74 0.98 4.51 1.45 2.83 3.51

TEMP 12.82 13.78 14.31 11.69 11.51 12.67 14.25 9.30

This report is copyright to 2014 GeoModel Solar s.r.o., all rights reserved. SolarGIS is a registered trade mark of GeoModel Solar

S is a registered trade mark of GeoModel Solar s.r.o.