Schlumberger Heat

CF COMBI
COMPACT HEAT METER

Modular design : Replaceable battery, Easy installation and maintenance, Communication module can be inserted on site. Fixed date reading. Flexible in communication : Multifunction display, Input for 2 water meters, M-BUS output, Energy pulse output.

- Conforms to O.I.M.L R75 and EN 1434. - Approved in all European countries : Germany (P.T.B), France (DRIRE), Sweden, Poland, CIS, etc. Schlumberger applie an environmental protection policy in accordance with its HSE commitment.

Schlumberger Heat

MODULAR DESIGN
This modular design provides considerable flexibility in adapting the CF Combi to the users needs : Integrator may be offset and rotated to facilitate installation and use, Separable metrological subassemblies (hydraulic part / integrator / probes*) for maintenance and for tests (individual, periodic, etc.), Replaceable battery**, Communication functions useable on site (depending on originally installed equipment) due to a removable interface.
* Only for seven-year battery version ** By a competent person

COMMUNICATION FIXED DATE READING


Reading once every year on fixed date (choice of month ca be programmed*** on site by the user). Reading of the CF Combi Energy index for the previous 2 years on fixed date. Reading of the Volume index for 2 water meters for the 2 previous years on fixed date - if the water meter inputs option was chosen. The following communication options are available if optional modules are added for use with the originally installed equipment : 2 WATER METER INPUTS : - Inputs compatible with the pulse standard : reed switch, unpolarized type, 100 L. - Connected water meter start indexes updated *** on site STANDARD M-BUS OUTPUT for remote reading : - M-BUS communication protocol - On site programming*** of remote reading addresses. Energy PULSE OUTPUT : - Reed switch, unpolarized type.

AUTOMATIC INTERNAL CHECK


Continuous monitoring by self test. Totalization of the time in alarm.

S.I STANDARD BUS OUTPUT for remote reading : - S.I. BUS communication protocol - On site programming*** of remote reading addresses.
*** No equipment is necessary

Schlumberger Heat

RANGE
INTEGRATOR Operating range : Application : Flow meter position : Energy unit : SENSOR Type : T: 0 C - 160 C T : 0 C - 160 C Heating or cooling Supply or return MWh or GJ Pt100 - IEC 751 Class B Direct immersion ou pocket sensor 90 C or 110 C 0.6 m3/h - 1 m3/h** - 1,5 m3/h - 2,5 m3/h 16 bars
* Please call us for other flows ** 90C only

FLOW METER

Temperature of use : Qn* : PN :

Example of models :

Heating - 90 C

Heating - 110 C

Cooling

MULTIFUNCTION DISPLAY
Level 1
Energy Energy year -1 Energy year - 2 Display test

Level 2
Water meter 1 index (current year) Water meter 2 index (current year) Water meter 1 index (year-1) Water meter 2 index (year-1) Water meter 1 index (year-2) Water meter 2 index (year-2)

Level 3
Volume index Instantaneous flow Max. flow Temperature difference Supply temperature Return temperature Instantaneous power Max. power Alarm duration

Previous

Next
Standard display

Several display levels available.


The various levels are accessible by simultaneously pressing the two push buttons on the front.

Additional display for option with water meter equipment

Schlumberger Heat

CATALOGUE
Original comm. equipment *
M-BUS/Water meter SI-BUS/Energy pulse
* Associated module to be ordered separately

Maximum temperature
90 C 110 C

Application
Heating Cooling

Nominal Flow
0,6 m3/h 1 m3/h ** 1,5 m3/h 2,5 m3/h

Battery
7 years (7 +1 years) 10 ans (10 +1 year)

Flow meter position


Supply Return

Energy unit
MWh GJ

Sensors
Pocket sensor *** Direct immersion

** 90C only and for heating application *** 90C maximum only

TECHNICAL CHARACTERISTICS
Metrology Temperature range Temperature T Typical accuracy Enthalpy coefficient K Power supply : battery Displays Mechanical protection Electromagnetic compatibility Ambient temperature Pulse value : - Display units Save Maximum offset distance PTB, DRIRE, OIML R75, EN 1434 20 - 90 C / 0 - 110 C / 0 - 90 C 3 - 70 C / 3 - 110 C / 3 - 90 C (0.2 + 0.5/T) % - ASIC acquisition circuit Variable, automatic correction 3 VDC battery, lithium manganese battery - mercury free Life : 7 years (+ 1 year storage) 1.8 Ah or 10 years (+ 1 year storage) 2.5 Ah 7 digits - liquid crystal (LCD) > IP 54 EC : EN5081-1, EN5082-1 5 - 55 C 1 or 2.5 liters - configuration stored in the EEPROM Energy : 0,001 MWh ou 0,01 GJ - Volume : 0,01 m3 Index and configuration stored permanently (EEPROM) 1.3 meters with wall support supplied

COMMUNICATION MODULE, to be chosen from one of the following options : S.I. BUS and Energy pulse outputs M-BUS output and water meter input Schlumberger BUS 20 mA - 30 V - 500 ms - not polarized 300 or 2400 Bauds - IEC 870-5 - M-BUS protocol 100 liters, Free potential

HYDRAULIC PART OF THE CF Combi Version* ( m3/h) Qmin horizontal position (l/h) Qmin vertical position (l/h) A - length (mm) Weight (Kg) Meter pipe thread Connection pipe thread Class Pressure loss at Qn (mbar) Qn 0,6 12 24 110 1,3 G3/4B G1/2B B-H/A-V 200 Qn 1 20 40 110 1,3 G3/4B G1/2B B-H/A-V 200 Qn 1,5 30 60 110 1,3 G3/4B G1/2B B-H/A-V 200 Qn 2,5 100 130 1,4 G1B G3/4B B-H/A-V 200 50

DIMENSIONS
34 71
CF combi

75 / 50

* Please call us for other versions.

Schlumberger - Water & Heat 50, Avenue Jean Jaurs, BP 620.03 92120 Montrouge - FRANCE Tl. : (33) (1) 47 46 61 00 Fax : (33) (1) 47 46 56 66
Schlumberger is bound by the foregoing specifications only after confirmation.

97 ME 34 - 7/97 - imprim en France par Mosaque

110 85

85

115 / 90