You are on page 1of 3

KVA

KVA is Kilo volt amperes.It's the product of voltage and current. It's the unit of power in electrical terms.When we multiply KVA with the powerfactor,we get kilowatts. Mathematically

Single phase kVA to amps calculation formula


The current I in amps is equal to 1000 times the apparent power S in kilovolt-amps, divided by the voltage V in volts:

I(A) = 1000 S(kVA) / V(V)


3 phase kVA to amps calculation formula
Calculation with line to line voltage
The current I in amps (with balanced loads) is equal to 1000 times the apparent power S in kilovolt-amps, divided by the square root of 3 times the line to line voltage VL-L in volts:

I(A) = 1000 S(kVA) / (3 VL-L(V) )


Calculation with line to neutral voltage
The current I in amps (with balanced loads) is equal to 1000 times the apparent power S in kilovolt-amps, divided by 3 times the line to neutral voltage VL-N in volts:

I(A) = 1000 S(kVA) / (3 VL-N(V) )

KVA, Voltage and Current Calculator

KVA, Voltage and Current Calculation

KVA Calculator is an online tool used in electrical engineering to measure the unknown quantity by two known quantities applied to the below formulas for single phase and three phase connection. To calculate KVA, you need to enter the known values of voltage and the current into the respective fields. These two values are applied to the below formulas used in this KVA Calculator to calculate the unknown quantity KVA. For single phase connection, KVA can be mathematically derived from this below

Find Value of

KVA

Amps A

Volt
formula For three phase connection, KVA can be mathematically derived from this below formula

KVA

Type of Service
Voltage Calculator is also used in electrical engineering to measure the unknown voltage by two known quantities KVA and current applied to the below formulas. For single phase connection, voltage can be mathematically derived from this below formula

Advertisement

For three phase connection, voltage can be mathematically derived from this below formula

Current Calculator is also used in electrical engineering to measure the unknown current by two known quantities KVA and voltage applied to the below formulas. For single phase connection, current can be mathematically derived from this below formula

For three phase connection, current can be mathematically derived from this below formula

Answer:
First determine what voltage is needed for phase to phase. Where you work on or where the gears are coming from would help to answer this question. In Southeast Asia, where power is 220~240 volts, a 3 phase system would be 415v phase to phase. In North america, a 3 phase system would be 208v phase to phase. So now you know the voltage that you are working with on a 3 phase system. Next use this formula, kVA x 1000 / voltage required / 1.73 = amp 3 phase Example, you have a 60kVA generator. And you working in North America, which is 208v phase to phase. 60 kVA x 1000 / 208 v / 1.73 = 166amp 3 phase Written by: Rony Xu Hope this helps!

atheist plumb shudder ascetic voluptuous

you cant believe a thing while you are ignorant the thing is.

You might also like