Vacuum Contactor
Concept The high vacuum is one of the best dielectric media available for switching a high power electrical circuit. It enables designers to have minimum contact separation, low mechanism energy & hence makes the design compact. A very compact vacuum interrupter is resin encapsulated to increase the external creepage to form an Insulated Arc Interruption Device attached with a sturdy mechanism to yield the most compact Vacuum Contactor of its kind. The features of this contactor are as below. The mechanical latch or magnetic actuator design is also available upon special requirement.

Front View of a Typical L.V. Vacuum Contactor

Inside view of M.V. Vacuum Contactor (Solenoid Type)

Vacuum Contactor Trolly


Conventionally the motor switching in medium voltage range was done by the oil or SF6 circuit breakers. These circuit breakers which are basically designed for high current interruption with very high energy mechanisms are too unnecessary for switching the comparatively smaller loads. The frequent switching of such smaller loads results into exhausting the life of mechanisms or compels for higher maintenance. The vacuum contactor fuse combinations mounted on a trolley is a perfect solution giving a very high mechanism life. This trolley with new panels or retrofitting arrangement is an optimum solution.

Technical Specifications
Parameter VC400 Frequency Rated Insulation voltage Rated Operational voltage Rated Operational Current Making current AC4 / AC3* Breaking current AC4 / AC3* Short time current / time Switching mechanism Switching frequncy (max) AC1 Switching frequncy AC2 AC3 AC4 Mechanical Life (ops) Electrical Dielectric Withstand Impulse Withstand Closing time Opening time No of Aux.Contacts Rated Control voltage AC Rated Control voltage DC Tripping Voltage Closing Coil Inrush Current (220V) Holding Current Tripping Inrush current Coil Excitation Motor Application Transformer Capacitor Weight (approx.) 50 1.0 0.690 400 4 3.2 3.2/10 VC630 50 1.0 0.690 630 6.3 5.04 5.04/10 Vacuum Contactor Type VC400XL 50 1.1 1.100 400 4 3.2 3.2/10 MVC400 50 7.2 3.3/6.6 400 4 3.2 9/1 MVC400L 50 7.2 3.3/6.6 400 4 3.2 9/1 Mech. 300 0.25 0.25 28 60 115 25 CSVP11 50 12 11 400 4 3.2 9/1 Solenoid 1000 1 0.25 28 75 50-70 CSVP11L 50 12 11 400 4 3.2 9/1 Mech. 1000 0.2 0.2 28 75 50-70 HVC400 50 12 11 400 4 3.2 9/1 S/M 1000 1 0.25 28 75 50-70 Hz kV kV Amp kA rms kA rms kA/Sec. Ops/Hr. Ops/Hr. Ops/Hr. Ops/Hr. Ops/Hr. Millions Millions kV-1 min kVp ms ms Volt Volt Amp Amp Amp kW kVA kVAR Kg Units

Solenoid Solenoid Solenoid Solenoid 700 200 500 500 5 0.5 700 200 500 150 5 0.5 700 200 500 500 5 0.5 1200 2.5 0.25 28 60 115

70-100 70-100 70-100

4NO+4NC 4NO+4NC 4NO+4NC 3NO+4NC 4NO+4NC 3NO+4NC 4NO+4NC 4NO+4NC 110, 220, 240 & 415 24, 48, 110 & 220 Cont. 12 Cont. 20 Cont. 20 220 220 4.2 1 max. Cont. 1500 2000 2000 23 220 220 220 4.2 1 Pulse 1500 2000 2000 24 220/110 220/110 220/110 220/110 220/110 220/110 4.2 1 max. Cont. 6000 7500 1000 40 4.2 1 Pulse 6000 7500 1000 45 4.2 1 max. Cont./Pulse 6000 7500 1000 125

220/110 220/110 220/110 V AC/DC

* AC3 for VC-400, VC-630 and VC-400XL and AC4 for balance all. Notes : 1) 2) 3) 4) 5) 6) 7) 8) 9) Other coil voltages can be made available upon request. Standard AC Control Voltages can be provided on enquiry. MVC-400 and CS-VP11 : The conventional mechanism of closing & holding by electromagnet and opening by spring. MVC-400L and CS-VP11L : The electromagnetic coil for closing, a mechanical latch for holding delatching by an electromagnetic coil and opening by a spring. MVC-400XL : Electromagnetic coils are used for closing as well as opening and permanent magnet is used to hold contactor in closed or open condition. HVC-400 is metalclad outdoor vacuum contactor. Fuse selection recommendation : To be backed up by suitable short circuit protective devices. Suitable for retrofitting with existing M.O.C.B. motor switching arrangements. Surge supressors are available on request as an optional arrangement.

Applicable Standards :

VC series - IEC 60947 part IV secton 1 / IS 13947 part 4 section 1 MVC-400 series - IEC 470 / IS 9646 / BS 775 CS-VP11, CS-VP11L and HVC-400 - IEC 470 / IS 9046 / BS 775 / IEC 265 / IS 9920

For the disposal of product and packing material please adopt Local/National Legislation of waste disposal.

Vacuum Contactor Applications :

Motor Switching Transformer Switching

Capacitor Switching Furnace Switching

Vacuum Contactor Assembly and Testing :

Vacuum Interrupters Lab.


S-6 Division, D-2, M.I.D.C. Waluj, Aurangabad - 431 136 India. Tel : +91-240-2554662, 2554371, 2554372, 2554558, 2554559. Fax : +91-240-2554697 E-mail : Girish.Magre@cgl.co.in Web : www.cgvi.com, cglonline.com Regd. Office : Crompton Greaves Ltd., 6th Floor, CG House, Dr. Annie Besant Road, Worli, Mumbai - 400 030.