60 Hz
Standby
(2)
Rated output Active power output * Rated speed Standard Voltage Voltage available
kVA kW r.p.m. V V
991 792
1.046 837
Performance data refers to Standard Reference Conditions of ISO 8528 : + 25 C , 100 m ALT, relative humidity 30 % During running-in period the output increases by approx. 5 % which is taken into consideration at delivery. Power reduction acc. to DIN ISO 3046. Standard values: Above 100 m ALT approx. 1 % per 100 m. Above 25 C (77 F) approx. 4 % per 10 C (50 F). * Considering cos phi= 0,8
1.800 r.p.m.
Standby
(2)
Rated output Manufacturer Engine model 4 stroke Diesel Engine - Injection type Aspiration type Cylinders, number and arrangement Bore x stroke Total displacement Cooling system Lube oil specifications Compression ratio Specific fuel consumption (P.R.P) Specific oil consumption (at full load) Lube oil maximum capacity Total coolant capacity Speed governor Air filter
kW
838
924
mm L
PERKINS 4008 - TAG2 DIRECT TURBOCHARGED AND AFTERCOOLED 8-L 160 x 190 30,56 WATER SAE 15 W 40 13,6 : 1 221 0,25 153 162 Electronic DRY
(1) Prime Power (P.R.P.) - ISO 8528: prime power is the maximum power available during a variable power sequence, which may be run for an unlimited number of hours per year, between stated maintenance intervals. The permissible average power output during a 24 hours period shall not exceed 80% of the prime power. 10% overload available for governing purposes only. (2) Max Stand-by power (ISO 3046 Fuel Stop power): power available for use at variable loads for limited annual time (500h), within the following limits of maximum operating time: 100% loads 25 h per year - 90% loads 200 h per year No overload available. Applicable in case of failure of the main in areas of reliable electrical network.
Synchronous Generator *
Poles Winding connections (standard) Frame mounting Insulation Enclosure (according to IEC-34-5) Exciter system Voltage regulator Steady voltage precision
N
4 Star - serie SAE 0 - 18 H IP 23 Self-regulating Brushless A.V.R + PMG (Electronic) within 1,5% from no load to full loading with cosf=0,81
class
*Alternator used by HIMOINSA Gensets meet the requirements of following Standard: BS5000, VDE 0530, NEMA MG1-32, IEC34, CSA C22.2-100, AS1359.
2 x 152 72 2.542
8,2 11,15
2 x 178
24V 153
999 999
WEIGHT AND DIMENSIONS OPEN SKID GENSET Length Width Height Shipping volume seaworthy (Standard supplier) Dry weight (with standard accessories) WEIGHT AND DIMENSIONS SOUNDPROOFED GENSET Length Width Height Shipping volume seaworthy (Standard supplier) Dry weight (with standard accessories) Sound level at 7m WEIGHT AND DIMENSIONS SOUNDPROOFED CONTAINER 30'' Length Width Height Shipping volume seaworthy (Standard supplier) Dry weight (with standard accessories) Sound level at 7m
m - ft m - ft m - ft m3 - ft3 kg - lb
5,15 1,9 2,8 27,39 7.900 7,05 1,9 2,6 34,82 8.400
N/A
16,89 6,23 9,18 965,96 17.380 23,08 6,22 8,51 1.221,6 18.480
m - ft m - ft m - ft m3 - ft3 kg - lb dB(A)
m - ft m - ft m - ft m3 - ft3 kg - lb dB(A)
N/A
Local distributor