INTRINSICALLY SAFE PRESSURE TRANSMITTER TM/Ex

20

II 1G EEx ia IIC T3...T6


Features
Compact and robust stainless steel assembly 1.4435 (316L) Piezoresistive measuring element Gauge, absolute or sealed gauge Standard DIN pressure ranges from 0100 mbar to 01000 bar Calibration available for all common pressure units High reliability Short delivery time Customized versions due to modular assembly Low current consumption due to the high input impedance Media temperature up to 150C (optional)

Typical applications Drucktransmitter mit piezoresitivem Messelement.


Machine installations Industrial process control Heating and ventilation Environmental monitoring Food industry Mobile hydraulics Test and calibration systems In hazardous areas

- feel the Dif ference

Specifications
Pressure range Overpressure [bar] 0.1 0.5 3 bar > 0.5 2 3 x FS
(min. 3 bar)

> 2 25 3 x FS

> 25 600 3 x FS
(max. 850 bar, optional up to 1500 bar)

> 600 1000 1500 bar

Burst pressure Accuracy1) Thermal shift Zero Span Response time Long term stability (1 year)
1)

[bar] [ % FS] [ % FS/C] 070C -2585C 070C -2585C

> 200 0.5

> 200 0.5

> 200 0.5

> 850
(optional up to 1500 bar)

1500 1

(optional 0.25)

(optional 0.25)

(optional 0.25)

0.5

(optional 0.5)

0.06 0.08 0.015 0.02 < 1 ms/1090% FS < 4 mbar

0.03 0.04 0.015 0.02

0.015 0.02 0.015 0.02

0.015 0.02 0.015 0.02

0.015 0.02 0.015 0.02

< 4 mbar

< 0.2% FS

< 0.2% FS

< 0.2% FS

Zero based non-conformity according to DIN 16086, including hysteresis and repeatability

Electrical data
Pressure range Full scale signal
(10V DC voltage supply)

[bar] [mV]

up to 0.25 15

> 0.25 0.6 25 Connection

> 0.6 1 35

> 1 2.5 50

> 2.5 100

Electrical connection

+Vin

+Out

GND - Out

Input impedance Bridge resistance

> 10 kOhm 3 kOhm, typ. Materials

Process connection, diaphragm, housing Seals (standard)

Stainless steel 1.4435 (316L) Viton

(other materials on request) (other materials see ordering information)

The pressure transmitter TM/Ex fulfill the emission and immunity requirements described in the EMC directive 89/336/EEC.

Pressure Connection

Dimensions
Version for media temperature up to 100C

Electrical Connection
46.5

Pin 1 2 3 +Vin +Out GND


- Out

G 1/4 F

SW27

32,5

Fig. 1

24

22

Fig. 10

3 1 2

12
G 1/4 M

SW27

Version for media temperature up to 150C


32,5 16
G 1/4 M

Fig. 2
24

Fig. 11
SW27
49

68

35,5 13,5

Fig. 3

Cable socket connector


3 2 4 5

G 1/2 M

SW27

Pin
32,5
20,5

Fig. 4

74.5

1 2 3 4

+Out - Out +Vin GND

G 1/2 M 18,4

SW27

Fig. 12 Fig. 5
Cable socket connector
A B F E D

34,5

19,5

G 1/2 M

18,4

SW27

33,5

Fig. 6
62.5

Pin A B C D +Vin GND +Out - Out

25
G 1/2 M

Fig. 13
SW27

43

Fig. 7

Colour white yellow brown green +Vin GND +Out - Out

17
1/2 NPT M
PG9

31,5

SW27

Fig. 14

Fig. 8