Product data sheet membrane type:

Capacity at nominal conditions nitrogen content [%] 99.5 Capacity 1.0 [Nm3/hr] Nominal conditions: operating pressure: temperature: ambient pressure:

NG 3 H
99 1.6 98 2.6 97 3.4 96 4.5 95 5.3

7 bar(g)/105 psig 20 C/ 68 F 1013 mbar(a)/ 1 atm

Calculation of capacity at membrane pressures different from the nominal pressure multiply nominal capacity by correction factor for the actual membrane pressure as given below Pressure 4/60 5/75 6/90 7/105 8/120 9/135 10/150 11/165 12/180 [bar(g)]/[psig] correction factor 0.4 0.6 0.8 1.0 1.2 1.3 1.5 1.6 1.7 Calculation of air requirements multiply capacity by airfactor as given below nitrogen content [%] 99.5 99 Air-factor 8.5 6.0 Compressed air specifications max. operating pressure : compressed air temperature: compressed air temperature range: residual oil content : particles: relative humidity: Ambient conditions ambient temperature range: ambient pressure: air quality: Dimensions and connections Dimensions L x H x D [mm3] Weight [kg] connections: inlet/outlet vent Deviating features on request

98 4.3

97 3.5

96 3.0

95 2.6

13.0 bar(g)/188 psig 10 C above ambient 2 - 50 C/ 36 - 122 F < 0.01 mg/m3 filtered at 0.01 cut off 100 % (non condensing)

2-40 C/ 36-104 F (frostfree) atmospheric inlet air must be normally clean air without vapours of organic compounds as well as other contaminants 270 x 764 x 84 16.3 BSP BSP

Attention Aquilo gas separation membranes separate oxygen from pressurised air. The composition of the product is determined by measuring the residual oxygen content. The nitrogen content is calculated by subtracting the residual oxygen content from 100 %. Air is composed of nitrogen (78.1%), oxygen (20.9 %), Argon (0.9 %), CO2 (0.03 %), and some trace inert gases. Therefore it should be born in mind that the value that is normally called the nitrogen content actually is the inert gas content. The nitrogen produced should, with the exception of the reduced oxygen concentration, be treated as pressurised air. If special purity is required appropriate post treatment of the nitrogen must be provided.

Aquilo Gas Separation BV Oude Kerkstraat 4 4870 AG ETTEN-LEUR Tel. + 31 76 5085300; Fax + 31 76 5085333

Aquilo reserves the right to make alterations doc code: 9.12.03. 9.29 rev 0 printed 1/02/99

Dimensional drawing of NG 3 H

Installation instructions: 1. NG 3 H module should be positioned upright as shown above 2. Mounting can be done with the aid of the socket screws that keep the lock-up plates in position; never pressurise the module when the socket screws bolts and the metal sheets are not in their original position as this can lead to serious injury 3. Installation according to manual titled Aquilo gas separation membranes: Installation Manual: Instructions for manufacturing nitrogen generators (Aquilo document: 9.00.00.9.06 rev. 0)