Professional Documents
Culture Documents
3-I
p. 12
OPTI-0.3-TL
p. 18
page 10 to page 21
PVI-2000/3600 UNO-2.0-I UNO-2.5-I PVI-2000-OUTD p. 24 p. 28 p. 32 PVI-3.0-TL PVI-3.6-TL PVI-4.2-TL PVI-3.8-I PVI-4.6-I p. 34
p. 40
PVI-10.0-I PVI-12.0-I
p. 54
TRIO-27.6-TL TRIO-20.0-TL
p. 64
page 22 to page 67
p. 70
PVI-165.0/220.0 PVI-275.0/330.0
p. 80 p. 82 PVI-CENTRAL-250 p. 88 PVI-CENTRAL-300
page 68 to page 97
STATION
p. 100
p. 108 p. 110
p. 124
MSWI-55.0/110.0 MSWI-50/100-US
p. 136 PVI-12.5-TL-W p. 140 SSWI-10.0-I p. 148 PVI-5000-TL-W PVI-6000-TL-W p. 152 p. 160 PVI-3.0-TL-W PVI-3.6-TL-W PVI-4.2-TL-W p. 172
p. 188 CONTACTS
p. 196
SERVICE
WIND
LSWI-2.5MW
p. 132
p. 144
p. 156
SSWI-3.8-I SSWI-4.6-I
p. 166
VISION
STATION
PVI-250.0-TL PVI-500.0-TL
PVI-55.0/110.0
p. 78
PVI-CENTRAL-50 p. 84 PVI-CENTRAL-100
PVI-ULTRA
p. 94
UNO TRIO
PVI-5000-TL PVI-6000-TL
p. 46
PVI-10.0-TL PVI-12.5-TL
p. 60
MICRO OPTIMIZER
RESIDENTIAL PV INVERTERS
NEW
MICRO-0.25-I MICRO-0.3-I
NEW
OPTI-0.3-TL
300W - 4 kW
PVI-2000 PVI-3600
NEW
UNO-2.0-I UNO-2.5-I PVI-3.0-TL PVI-3.6-TL PVI-3.8-I
NEW
PVI-250.0-TL PVI-500.0-TL
55 kW - 1400 kW
PVI-CENTRAL-50/100 PVI-55.0/110.0 PVI-165.0/220.0 PVI-275.0/330.0 PVI-250-US PVI-300-US
NEW
ULTRA-700-TL ULTRA-1050-TL ULTRA-1400-TL
3 kW - 6 kW
PVI-3.0-TL-W PVI-3.6-TL-W PVI-4.2-TL-W SSWI-3.8-I SSWI-4.6-I PVI-5000-TL-W PVI-6000-TL-W SSWI-10.0-I PVI-12.5-TL-W
10 kW - 25 kW
4000 WIND INTERFACE 7200 WIND INTERFACE 25kW-WIND-INTERFACE
Small Wind
COMMERCIAL PV INVERTERS
4 kW - 30 kW
PVI-4.2-TL PVI-4.6-I PVI-5000-TL PVI-6000-TL PVI-10.0-TL PVI-10.0-I PVI-12.0-I PVI-12.5-TL
NEW
TRIO-20.0-TL TRIO-27.6-TL
PV STATION
turnkey solutions
STATION 440/660-IT/DE STATION 770/1000-IT/DE STATION 1000/1320-IT/DE/US
NEW
AURORA UNIVERSAL
NEW
AURORA ENVIRONMENTAL PVI-AEC-EVO PVI-DESKTOP
55 kW - 110 kW
MSWI-55.0 MSWI-110.0 MSWI-50-US MSWI-100-US LSWI-2.5MW
Medium Wind
Large Wind
Welcome
As President of Power-Ones Renewable Energy Solutions, I am excited to showcase our broad array of products and services for the Solar and Wind markets. Power-One has a long-standing history in the global power electronics industry, providing a four-decades strong foundation for our technology innovation, quality and service within the Renewable Energy industry. If you are new to our products, we offer the full range of photovoltaic and wind products, from small residential inverters to large utility-grade units. From the contents of this brochure, you will find that we offer a diverse range of solutions to meet the needs of every installation. At Power-One, our objective is to be the best-in-class for on-time delivery, reliability and yield. Since 2009, our company has risen from the number nine position amongst the worlds solar inverter manufacturers to the number two global position, shipping 2.6 GW of inverters in 2010. With our global presence, including design, manufacturing, sales and service in Asia, Europe and the Americas, we offer flexibility, regionally specific products and rapid manufacturing and service response times for our customers throughout the world. Our broad array of Aurora products offers industry leading efficiency and reliability, providing customers with a technologically advanced product that produces higher yields than our competitors. In fact, Photon Magazine said our European 10.0kW three-phase inverter, which received their A+ rating, takes its place among the top devices Photon Lab has tested so far. Coupled with our innovative technology, we also provide our customers with excellent pre- and post-sales service. This ensures their orders are not only correct to their specification before they receive the product, but that they also have an efficient care package for increased uptime throughout the life of the inverter. This enables us to be more of a partner than a supplier to our customers, as we like to think of ourselves as our customers manufacturing arm no different than if we were within their organizations. On behalf of a very hard working team, we are looking forward to working with you as we provide our leading design, technology and service to meet your renewable energy needs. I encourage you to contact Power-One Renewable Energy Solutions team so that we can be the supplier of choice for all of your future renewable energy projects. With best wishes
This global catalogue introduces a certain number of new products to the Power-One Aurora range. So far we have installed products totaling more than 4 GW of power globally. We have redesigned the smallest of our residential inverters, the new UNO 2 kW single phase inverter. A new look inverter from both a style and technology standpoint, it is high performing, extremely robust, easily installed and features a new user interface. Other important news includes two new string inverter products for large roof top applications, TRIO-27.6 and TRIO-20.0, three-phase inverters outputting 27.6 kW and 20.0 kW respectively. These products fill a gap between our previous 10.0 kW and 12.5 kW three-phase products and our smallest Central inverter products (50kW and 55kW). This new design of inverter benefits from three-phase inverter technology perfected in the PVI-10.0 and 12.5, probably the worlds most commonly used three-phase inverter which has led the way in best-in-class efficiency. Power-One is also launching the new ULTRA, our biggest inverter with an output of up to 1.4MW featuring passive liquid cooling. This new concept in large scale utility inverter features an IP65 enclosure, high performances, minimum footprint, low maintenance and Power-Ones traditional modular approach. All this plus a low operational cost benefit for our customers.
Key Features of the Aurora product range Power-Ones Aurora products compare favorably with the competition for the high innovation content and key features which are the stronghold of our offering. The wide working input voltage range can accommodate any panel string size, allowing installers to buy their inverter with confidence knowing the Aurora inverter will suit whatever installation they have on their books. The wide input range also allows a low power of activation to extend the daily working time of the inverter. The Aurora inverters also feature a rugged IP65 construction to fit any type of installation without putting restrictions on where and how the inverter should be installed. Maximum power-point trackers (MPPT) allow you to accommodate sub arrays with different orientations or made up of different PV panels. This technology also allows the installation designer to know that any incidents of partial shading will be overcome by the MPPT technology creating the optimum power curve for energy harvesting. Modular central inverters, used for large commercial and utility scale applications, allow a reduction in downtime caused either by the failure at the inverter level or the photovoltaic field. This eliminates plant shutdown, the reduction of repair time and consequently financial benefits in terms of production. At Power-One, we aim high so you can too.
10
AURORA MICRO
MICRO
AURORA MICRO
11
MICRO OPTIMIZER
MICRO-0.25-I MICRO-0.3-I
GENERAL SPECIFICATIONS OUTDOOR MODELS
MICRO-0.25-I-OUTD-230 MICRO-0.25-I-OUTD-208/240 MICRO-0.3-I-OUTD-230 MICRO-0.3-I-OUTD-208/240
NEW
12
AURORA MICRO
The new Aurora 300 Watt micro-inverter product offers something new to Power-One customers. The ability to individually link all modules within a specific installation is an alternative to the traditional Aurora string inverters Power-One is famous for. Micro-inverters have some advantages over string inverters. They allow you to control the panels output individually and offer Maximum Power Point Tracking (MPPT) for each single module. They also allow you to control individual panels in different ways and reduce the losses in efficiency in a variety of challenging conditions.
Features
Electrolyte-free power converter to further increase the life expectancy and long term reliability Outdoor enclosure for unrestricted use under any environmental conditions Increased energy harvesting thanks to the MPPT algorithm which works at the level of each solar
panel in any light condition No DC input current ripple The HF isolation allows it to fit any application that requires the grounding of either one of the input terminations 95.5% of efficiency Ease of installation by the implementation of a package inclusive of proprietary wireless communication hub and grid interface Reduced susceptibility to fault. In case of a component failure only the energy produced from one PV module will be lost Up to 10 micro inverters directly connectable in a string
AURORA MICRO
13
MICRO OPTIMIZER
MPPT 1 (DC/DC) +
HF TRANSFORMER
BULK CAPS
IN1
N1 L2(1)
L1(2) N2 L2(2)
PE
WIRELESS
CONTROL CIRCUIT
MICRO-0.3-I
97
MICRO-0.3-I
Efficiency [%]
55
96-97 95-96 94-95 93-94 92-93 91-92 90-91 89-90 88-89 87-88 86-87 85-86 84-85 83-84 82-83 81-82 80-81 79-80 78-79 77-78 76-77 75-76 74-75
96
50
95
Efficinecy [%]
94
93
Vin=35V
40
92
Vin=40V Vin=25V
91
35
90
0%
10%
20%
30%
40%
50%
60%
70%
80%
90%
100%
Pout [%@300W]
5%
10%
20%
30%
50%
75%
25 100%
Pout [% @300W]
14
AURORA MICRO
Vin [V]
45
PARAMETER
Input Side Maximum DC Input Power (Pdcmax) Operating DC Input Voltage Range (Vdcmin...Vdcmax) MPPT Input DC Voltage Range (VMPPTmin ... VMPPTmax) Absolute Maximum DC Input Voltage (Vmax,abs) Maximum DC Input Current (Idcmax) Number of DC Inputs Pairs for each MPPT DC Connection Type Start-up DC Input Voltage (Vstart) Output Side AC Grid Connection Type Rated AC Power (Pac,r) Rated AC Grid Voltage (Vac,r) AC Voltage Range (Vacmin...Vacmax) Maximum AC Output Current (Iac,max) Rated Output Frequency (fr) Output Frequency Range (fmin...fmax) Nominal Power Factor (Cosphiac,r) Maximum number of units per string Output Protection Anti-Islanding Protection Output Overvoltage Protection - Varistor Operating Performance Maximum Efficiency (max) Weighted Efficiency (EURO/CEC) Stand-by Consumption Communication Monitoring System (PC/Data logger) Remote Monitoring Environmental Ambient Temperature Range Relative Humidity Noise Emission Maximum Operating Altitude without Derating Physical Environmental Protection Rating Cooling Dimension (H x W x D) Weight Safety Isolation Level Marking Safety and EMC Standard Grid Standard Available Products Variants Standard
MICRO-0.25-IOUTD
265 Wp 18...58 V 20...50 V 65 V 10.0 A 1
MICRO-0.3-IOUTD
320 Wp 18...58 V 30...50 V 65 V 10.0 A 1
MICRO-0.25-IOUTD-US
265 Wp 18...58 V 20...50 V 65 V 10.0 A 1
MICRO-0.3-IOUTD-US
320 Wp 18...58 V 30...50 V 65 V 10.0 A 1
Tool Free PV connector WM Tool Free PV connector WM Tool Free PV connector WM Tool Free PV connector WM / MC4 / MC4 / MC4 / MC4 25V Single phase 250 W 230 V 180...264 V (1) 1.2 A 50 Hz 47...53 Hz > 0.95 10
(2)
25V Single phase 300 W 230 V 180...264 V (1) 1.5 A 50 Hz 47...53 Hz > 0.95 10
(2)
25V Single phase/Split phase 250 W 208 V / 240 V 183-228 V / 211-264 V 1.3 A 60 Hz 59.3...60.5 Hz > 0.95 10
25V Single phase/Split phase 300 W 208 V / 240 V 183-228 V / 211-264 V 1.15 A 60 Hz 59.3...60.5 Hz > 0.95 10
According to local standard According to local standard According to local standard According to local standard Yes 96.0% 95.4% / 95.5% < 50mW Wireless Wireless Yes 96.3% 95.5% / 95.5% < 50mW Wireless Wireless Yes 96.0% 95.4% / 95.5% < 50mW Wireless Wireless Yes 96.3% 95.5% / 95.5% < 50mW Wireless Wireless
-40...+85C / -40...185F with -40...+85C / -40...185F with -40...+85C / -40...185F with -40...+85C / -40...185F with derating above 65C/149F derating above 65C/149F derating above 65C/149F derating above 65C/149F 0...100 % condensing 0...100 % condensing 0...100 % condensing 0...100 % condensing < 30 db(A) @ 1 m 2000 m / 6560 ft IP 65 Natural < 30 db(A) @ 1 m 2000 m / 6560 ft IP 65 Natural < 30 db(A) @ 1 m 2000 m / 6560 ft NEMA 4X Natural < 30 db(A) @ 1 m 2000 m / 6560 ft NEMA 4X Natural
262mm x 244mm x 35mm / 262mm x 244mm x 35mm / 262mm x 244mm x 35mm / 262mm x 244mm x 35mm / 10.3 x 9.6 x 1.37 10.3 x 9.6 x 1.37 10.3 x 9.6 x 1.37 10.3 x 9.6 x 1.37 < 1.65 kg / 3.5 lb HF Transformer < 1.65 kg / 3.5 lb HF Transformer < 1.65 kg / 3.5 lb HF Transformer < 1.65 kg / 3.5 lb HF Transformer
CE CE cCSAus cCSAus EN61000-6-2, EN61000-6-3, EN61000-6-2, EN61000-6-3, EN 61000-6-2, EN 61000-6-3, EN 61000-6-2, EN 61000-6-3, EN61000-3-11, EN61000-3- EN61000-3-11, EN61000-3FCC Part15 Class B, UL 1741 FCC Part15 Class B, UL 1741 12, EN 50178 12, EN 50178 VDE0126-1-1, DK5940, AS4777, G83/1 VDE0126-1-1, DK5940, AS4777, G83/1 IEEE 1547 IEEE 1547
MICRO-0.25-I-OUTD-230
MICRO-0.3-I-OUTD-230
MICRO-0.25-I-OUTDUS-208/240
MICRO-0.3-I-OUTDUS-208/240
1. The AC voltage range may vary depending on specific country grid standard 2.The Frequency range may vary depending on specific country grid standard
AURORA MICRO
15
16
AURORA OPTIMIZER
OPTIMIZER
AURORA OPTIMIZER
17
MICRO OPTIMIZER
OPTI-0.3-TL
GENERAL SPECIFICATIONS OUTDOOR MODELS
OPTI-0.3-TL-OUTD OPTI-0.3-TL-OUTD-US
NEW
18
AURORA OPTIMIZER
Power-Ones new Optimizer products use DC-to-DC technology to help maximize the energy harvested from solar installations. Normally, within each array, the solar panels are usually joined together in a serial pattern. This creates issues if one panel fails as this reduces the energy being produced by the entire installation. The Optimizer maximizes the energy from each module within a string as they optimize the voltage/current for any given weather conditions. The Optimizer also maximizes energy harvesting in panels suffering from partial or temporary shading. This helps installers to create the largest installations possible and increase Return on Investment (ROI).
Features
Ability to mitigate PV panel mismatch High efficiency up to 99.5% Single panel MPP tracker compatible with all Power-One inverter models Ease of installation by the implementation of a package inclusive of proprietary wireless
data communication Temperature hardened construction
AURORA OPTIMIZER
19
MICRO OPTIMIZER
STRING CCOMBINER
INVERTER
OPTI 0.3
OPTI 0.3
OPTI 0.3
MPPT
MPPT
MPPT
WIRELESS
WIRELESS
WIRELESS
OPTI 0.3
OPTI 0.3
OPTI 0.3
MPPT
MPPT
MPPT
WIRELESS
WIRELESS
WIRELESS
OPTI 0.3
OPTI 0.3
OPTI 0.3
MPPT
MPPT
MPPT
WIRELESS
WIRELESS
WIRELESS
OPTI 0.3
OPTI 0.3
OPTI 0.3
MPPT
MPPT
MPPT
WIRELESS
WIRELESS
WIRELESS
Block Diagram
BLOCK DIAGRAM OF WIRELESS CONNECTION ARCHITECTURE
CG (COMMUNICATION GATEWAY)
INTERNET
OPTI-0.3*
OPTI-0.3*
OPTI-0.3*
OPTI-0.3*
OPTI-0.3*
OPTI-0.3*
OPTI-0.3*
OPTI-0.3*
OPTI-0.3*
OPTI-0.3*
OPTI-0.3*
OPTI-0.3*
20
AURORA OPTIMIZER
PARAMETER
Input Side Maximum Input Power (Pdcmax) MPP Input range (VMPPTmin-VMPPTmax) Absolute Maximum Input Voltage (Vmax,abs) Maximum Input Current (Idcmax) Number of DC Inputs Pairs DC Connection Type Maximum Output Power (Pdcmax) Output Voltage Range (VdcminVdcmax) Maximum Output Current (Idcmax) Output Reverse Polarity Protection Output Over Voltage Protection Operating Performance Maximum Efficiency (max) Pass Through Efficiency (pt) Weighted Efficiency (EURO/CEC) Communication Remote Control (Data logger; On/Off; Upgrade) User Interface Environmental Ambient Temperature Range Relative Humidity Noise Emission Operating Altitude Physical Environmental Protection Rating Cooling Dimension (H x W x D) Weight Safety Marking Safety and EMC Standard Available Products Variants Standard
1. Adjustable via wireless connection
OPTI-0.3-TL-OUTD
OPTI-0.3-TL-OUTD-US
300 Wp 20...60 V 65 V 10.0A 1 Tool Free PV connector WM / MC4 300W 20..60(1) V 12.0 A Yes > 60 V 98.0 % 99.3% 98.2% / 98.0% Wireless Not applicable -40...+65C / -40...169F 0...100% condensing < 30 db(A) @ 1 m 2000 m / 6560 ft IP 65 Natural < 0,6 kg / 1,32 lb CE EN 61000-6-2, EN 61000-6-3, FCC Part15 Class B, EN 50178 OPTI-0.3-TL-OUTD
300 Wp 20...60 V 65 V 10.0A 1 Tool Free PV connector WM / MC4 300W 20..60(1) V 12.0 A Yes > 60 V 98.0 % 99.3% 98.2% / 98.0% Wireless Not applicable -40...+65C / -40...169F 0...100% condensing < 30 db(A) @ 1 m 2000 m / 6560 ft NEMA 4X Natural < 0,6 kg / 1,32 lb cCSAus EN 61000-6-2, EN 61000-6-3, FCC Part15 Class B, UL 1741 OPTI-0.3-TL-OUTD-US
158mm x 169mm x 28.6mm / 6.2 x 6.65 x 1.12 158mm x 169mm x 28.6mm / 6.2 x 6.65 x 1.12
AURORA OPTIMIZER
21
22
AURORA UNO
UNO
AURORA UNO
23
UNO TRIO
PVI-2000 PVI-3600
GENERAL SPECIFICATIONS INDOOR MODELS
PVI-2000 PVI-3600
24
AURORA UNO
The smallest of Power-Ones Aurora PV string inverters, this unit is designed to be housed indoors as opposed to many of its outdoor counterparts. This small residential string inverter will work most effectively with small photovoltaic residential installations. This very compact, slim, lightweight and easy-to-install inverter offers a very cost effective entry point for users new to photovoltaics or in need of a simple power inverter solution. The inverter offers a range of benefits, including maximum energy harvesting, through both its high-speed Maximum Power Point Tracker (MPPT) and transformerless technology. The important parameter is the wide input voltage range making the inverter suitable to low power installations with reduced string size. The graphical display allows users to check real-time performance through its integrated data logger.
Features
Wide input range High speed and precise MPPT algorithm for real time power tracking and improved energy
harvesting Flat efficiency curves ensure high efficiency at all output levels ensuring consistent and stable performance across the entire input voltage and output power range RS-485 communication interface (for connection to laptop or datalogger) Compatible with PVI-RADIOMODULE for wireless communication with Aurora PVI-DESKTOP
AURORA UNO
25
UNO TRIO
MPPT (DC/DC)
BULK CAPS
INVERTER (DC/AC)
LINE FILTER
PE
STANDARD VERSION
(*) Not available for PVI-2000
RS485 + T/R - T/R RTN DC/DC DSP CONTR. DC/AC DSP CONTR. REMOTE CONTROL +R -R
CONTROL CIRCUIT
PVI-2000
99 99
PVI-3600
97
97
95
95
Efficiency, %
93
93
91
91
89
89
87 480 Vdc 85
87
480 Vdc
85 0% 10% 20% 30% 40% 50% 60% 70% 80% 90% 100% 0% 10% 20% 30% 40% 50% 60% 70% 80% 90% 100%
26
AURORA UNO
PARAMETER
Input Side Absolute Maximum DC Input Voltage (Vmax,abs) Start-up DC Input Voltage (Vstart) Operating DC Input Voltage Range (Vdcmin...Vdcmax) Rated DC Input Power (Pdcr) Number of Independent MPPT Maximum DC Input Power for each MPPT (PMPPTmax) MPPT Input DC Voltage Range (VMPPTmin,f ... VMPPTmax,f) at Pacr DC Input Voltage Range with Parallel Configuration of MPPT at Pacr DC Power Limitation with Parallel Configuration of MPPT DC Power Limitation for each MPPT with Independent Configuration of MPPT at Pacr , max unbalance example Maximum DC Input Current (Idcmax) / for each MPPT (IMPPTmax) Maximum Input Short Circuit Current for each MPPT Number of DC Inputs Pairs for each MPPT DC Connection Type Input Protection Reverse Polarity protection Input Over Voltage Protection for each MPPT - Varistor Photovoltaic Array Isolation Control Output Side AC Grid Connection Type Rated AC Power (Pacr) Maximum AC Output Power (Pacmax) Rated AC Grid Voltage (Vac,r) AC Voltage Range Maximum AC Output Current (Iac,max) Rated Output Frequency (fr) Output Frequency Range (fmin...fmax) Nominal Power Factor (Cosphiac,r) Total Current Harmonic Distortion AC Connection Type Output Protection Anti-Islanding Protection Maximum AC Overcurrent Protection Output Overvoltage Protection - Varistor Operating Performance Maximum Efficiency (max) Weighted Efficiency (EURO/CEC) Feed In Power Threshold Stand-by Consumption Communication Wired Local Monitoring Remote Monitoring Wireless Local Monitoring User Interface Environmental Ambient Temperature Range Relative Humidity Noise Emission Maximum Operating Altitude without Derating Physical Environmental Protection Rating Cooling Dimension (H x W x D) Weight Mounting System Safety Isolation Level Marking Safety and EMC Standard Grid Standard Available Products Variants Standard
1. Different DC connection type for specific country model 2. The AC voltage range may vary depending on specific country grid standard 3. The Frequency range may vary depending on specific country grid standard
PVI-2000
600 V 200 V (adj. 120...350 V) 0.7 x Vstart...580 V
PVI-3600
2100 W 1 2100 W Linear Derating From MAX to Null [530VVMPPT580V] 210...530 V Not applicable Not applicable Not applicable 10.0 A / 10.0 A
3800 W 2 2000 W
200...530 V 200...530 V Linear Derating From MAX to Null [530VVMPPT580V] 2000 W [200VVMPPT530V] the other channel: Pdcr-2000W [180VVMPPT530V] 20.0 A / 10.0 A 12.0 A 2
1 Tool Free PV Connector WM / MC 3 / MC 4 (1) Yes, from limited current source 2 According to local standard Single phase 2000 W 2000 W 230 V 180...264 V (2) 10.0 A 50 Hz 47...53 Hz (3) > 0.995 < 2.5 % Circular connector According to local standard 16.0 A 2 (L - N / L - PE) 95.5% 94.4% / 10.0 W < 8.0 W
3600 W 3600 W
16.0 A
20.0 A
96.0% 95.0% / -
PVI-USB-RS485_232 (opt.), PVI-DESKTOP (opt.) PVI-AEC-EVO (opt.), AURORA-UNIVERSAL (opt.) PVI-DESKTOP (opt.) with PVI-RADIOMODULE (opt.) Graphic display -20...+55C /-4...131F with derating above 40C/104F 0...95 % < 30 db(A) @ 1 m 2000 m / 6560 ft IP 21 Air Forced 440mm x 465mm x 57mm / 17.3 x 18.3 x 2.2 < 7.5 kg / 16.5 lb < 8.5 kg / 18.7 lb Wall bracket Transformerless CE EN 50178, EN61000-6-1, EN61000-6-3, EN61000-3-2, EN61000-3-3, AS/NZS 3100 DK 5940, VDE 0126-1-1, G83/1, AS 4777 PVI-2000 PVI-3600
AURORA UNO
27
UNO-2.0-I UNO-2.5-I
GENERAL SPECIFICATIONS OUTDOOR MODELS
UNO-2.0-I-OUTD UNO-2.5-I-OUTD
NEW
28
AURORA UNO
The UNO-2.0-I and UNO-2.5-I are the latest single phase string inverters in the Aurora range. A new-look inverter but packed with Power-Ones proven high performing technology. The new look inverter has new features including a special built-in heat sink compartment and front panel display system. The smallest of Power-Ones outdoor range, these new products are the right size for the average rooftop installation. This rugged outdoor inverter has been designed as a completely sealed unit to withstand the harshest environmental conditions. The high speed MPPT offers real-time power tracking and improved energy harvesting. Despite the isolated operation, the UNO-2.0-I and UNO-2.5-I feature an efficiency of 96.3%. The wide input voltage range makes the inverter suitable to low power installations with reduced string size.
Features
Each inverter is set on specific grid codes which can be selected in the field Single phase output Wide input range High speed and precise MPPT algorithm for real time power tracking and improved energy
harvesting Flat efficiency curves ensure high efficiency at all output levels ensuring consistent and stable performance across the entire input voltage and output power range Outdoor enclosure for unrestricted use under any environmental conditions RS-485 communication interface (for connection to laptop or datalogger) Compatible with PVI-RADIOMODULE for wireless communication with Aurora PVI-DESKTOP
AURORA UNO
29
UNO TRIO
IN1.1(+) IN1.2(+) +
IN1.1(+) IN1.2(+) + +
MPPT (DC/DC)
HF TRANSFORMER
BULK CAPS
INVERTER (DC/AC)
LINE FILTER
IN
IN -N
- PE
STANDARD VERSION
-S VERSION
RS485 + T/R - T/R RTN DC/DC DSP CONTR. DC/AC DSP CONTR. REMOTE CONTROL +R -R
CONTROL CIRCUIT
UNO-2.0-I-OUTD
99,00% 99,00%
UNO-2.5-I-OUTD
98,00%
98,00%
97,00%
97,00%
96,00%
96,00%
Efficiency, %
95,00%
Efficiency, %
200Vdc
95,00%
94,00%
94,00%
93,00%
93,00%
200Vdc
92,00%
300Vdc
92,00%
300Vdc
91,00%
350Vdc
91,00%
350Vdc
90,00% 0% 10% 20% 30% 40% 50% 60% 70% 80% 90% 100%
90,00% 0% 10% 20% 30% 40% 50% 60% 70% 80% 90% 100%
30
AURORA UNO
PARAMETER
Input Side Absolute Maximum DC Input Voltage (Vmax,abs) Start-up DC Input Voltage (Vstart) Operating DC Input Voltage Range (Vdcmin...Vdcmax) Rated DC Input Power (Pdcr) Number of Independent MPPT Maximum DC Input Power for each MPPT (PMPPTmax) MPPT Input DC Voltage Range (VMPPTmin,f ... VMPPTmax,f) at Pacr DC Power Limitation for each MPPT with Independent Configuration of MPPT at Pacr , max unbalance example Maximum DC Input Current (Idcmax) / for each MPPT (IMPPTmax) Maximum Input Short Circuit Current for each MPPT Number of DC Inputs Pairs for each MPPT DC Connection Type Input Protection Reverse Polarity protection Input Over Voltage Protection for each MPPT - Varistor Photovoltaic Array Isolation Control DC Switch Rating for each MPPT (-S Version) Output Side AC Grid Connection Type Rated AC Power (Pacr) Maximum AC Output Power (Pacmax) Rated AC Grid Voltage (Vac,r) AC Voltage Range Maximum AC Output Current (Iac,max) Rated Output Frequency (fr) Output Frequency Range (fmin...fmax) Nominal Power Factor (Cosphiac,r) Total Current Harmonic Distortion AC Connection Type Output Protection Anti-Islanding Protection Maximum AC Overcurrent Protection Output Overvoltage Protection - Varistor Operating Performance Maximum Efficiency (max) Weighted Efficiency (EURO/CEC) Feed In Power Threshold Stand-by Consumption Communication Wired Local Monitoring Remote Monitoring Wireless Local Monitoring User Interface Environmental Ambient Temperature Range Relative Humidity Noise Emission Maximum Operating Altitude without Derating Physical Environmental Protection Rating Cooling Dimension (H x W x D) Weight Mounting System Safety Isolation Level Marking Safety and EMC Standard Grid Standard Available Products Variants With DC Switch
1. The AC voltage range may vary depending on specific country grid standard 2. The Frequency range may vary depending on specific country grid standard 3. Night time consumption < 0.6W
UNO-2.0-I-OUTD
UNO-2.5-I-OUTD
2100 W
2600 W
2300 W Linear Derating From MAX to Null [470VVMPPT520V] 200...470 V Not applicable 10.0 A / 10.0 A
2900 W Linear Derating From MAX to Null [470VVMPPT520V] 205...470 V 12.8 A / 12.8 A
15.0 A 2 Tool Free PV Connector WM / MC4 Yes, from limited current source 2 According to local standard 16 A / 600 V Single phase 2000 W 2200 W 230 V 180...264 V (1) 10.0 A 50 Hz 47...53 Hz (2) > 0.995 (adj. 0.95) < 2% Screw terminal block According to local standard 15.0 A 2 (L - N / L - PE) 96.3% 95.0% / 24.0 W < 8.0 W (3) PVI-USB-RS485_232 (opt.), PVI-DESKTOP (opt.) PVI-AEC-EVO (opt.), AURORA-UNIVERSAL (opt.) PVI-DESKTOP (opt.) with PVI-RADIOMODULE (opt.) Graphic display -25...+60C (-13...+ 140F) with derating above 45C (113F) 0...100 % condensing < 50 db(A) @ 1 m 2000 m / 6560 ft IP 65 Natural 518mm x 367mm x 160mm / 20.4 x 14.4 x 6.3 < 17 kg / 37.4 lb Wall bracket HF transformer CE EN 50178, AS/NZS3100, AS/NZS 60950, EN61000-6-1, EN61000-6-3, EN61000-3-11, EN61000-3-12 Enel Guideline, VDE 0126-1-1, G83/1, EN 50438, RD1663, AS 4777 UNO-2.0-I-OUTD-S UNO-2.5-I-OUTD-S 12.0 A 2500 W 2750 W
AURORA UNO
31
PVI-2000-OUTD
GENERAL SPECIFICATIONS OUTDOOR MODELS
PVI-2000-OUTD
The transformerless operation of this compact outdoor residential inverter provides an efficiency of 95.5%. The high-speed Maximum Power Point Tracker (MPPT) produces real-time power tracking and improved energy harvesting. The wide input voltage range makes this inverter suitable to low power installations with reduced string size. This rugged outdoor inverter has been designed as a completely sealed unit to stand withstand the harshest environmental conditions. This small single string inverter features a front heat sink to keep the unit cleaner and more efficient over time.
Features
Wide input range High speed and precise MPPT algorithm for real time power tracking and improved energy harvesting Outdoor enclosure for unrestricted use under any environmental conditions RS-485 communication interface (for connection to laptop or datalogger) for wireless communication with Aurora PVI-DESKTOP Compatible with PVI-RADIOMODULE PVI-2000 OUTD OLD Prod1_Title Prod1_Part Nos Prod1_Prod Pic Prod1_Back Pic
32
AURORA UNO
PARAMETER
Input Side Absolute Maximum DC Input Voltage (Vmax,abs) Start-up DC Input Voltage (Vstart) Operating DC Input Voltage Range (Vdcmin...Vdcmax) Rated DC Input Power (Pdcr) Number of Independent MPPT Maximum DC Input Power for each MPPT (PMPPTmax) MPPT Input DC Voltage Range (VMPPTmin,f ... VMPPTmax,f) at Pacr DC Power Limitation for each MPPT with Independent Configuration of MPPT at Pacr , max unbalance example Maximum DC Input Current (Idcmax) / for each MPPT (IMPPTmax) Maximum Input Short Circuit Current for each MPPT Number of DC Inputs Pairs for each MPPT DC Connection Type Input Protection Reverse Polarity protection Input Over Voltage Protection for each MPPT - Varistor Photovoltaic Array Isolation Control Output Side AC Grid Connection Type Rated AC Power (Pacr) Maximum AC Output Power (Pacmax) Rated AC Grid Voltage (Vac,r) AC Voltage Range Maximum AC Output Current (Iac,max) Rated Output Frequency (fr) Output Frequency Range (fmin...fmax) Nominal Power Factor (Cosphiac,r) Total Current Harmonic Distortion AC Connection Type Output Protection Anti-Islanding Protection Maximum AC Overcurrent Protection Output Overvoltage Protection - Varistor Operating Performance Maximum Efficiency (max) Weighted Efficiency (EURO/CEC) Feed In Power Threshold Stand-by Consumption Communication Wired Local Monitoring Remote Monitoring Wireless Local Monitoring User Interface Environmental Ambient Temperature Range Relative Humidity Noise Emission Maximum Operating Altitude without Derating Physical Environmental Protection Rating Cooling Dimension (H x W x D) Weight Mounting System Safety Isolation Level Marking Safety and EMC Standard Grid Standard Available Products Variants Standard
1. The AC voltage range may vary depending on specific country grid standard 2. The Frequency range may vary depending on specific country grid standard
PVI-2000-OUTD
600 V 200 V (adj. 120...350 V) 0.7 x Vstart...580 V 2100 W 1 2100 W Linear Derating From MAX to Null [530VVMPPT580V] 210...530 V Not applicable 10.0 A / 10.0 A 12.0 A 1 Tool Free PV Connector WM / MC4 Yes, from limited current source 2 According to local standard Single phase 2000 W 2000 W 230 V 180...264 V (1) 10.0 A 50 Hz 47...53 Hz (2) > 0.995 < 2.5 % Circular connector According to local standard 16.0 A 2 (L - N / L - PE) 95.5% 94.4% / 10.0 W < 8.0 W PVI-USB-RS485_232 (opt.), PVI-DESKTOP (opt.) PVI-AEC-EVO (opt.), AURORA-UNIVERSAL (opt.) PVI-DESKTOP (opt.) with PVI-RADIOMODULE (opt.) 16 characters x 2 lines LCD display -25...+60C /-13...140F with derating above 40C/104F 0...100 % condensing < 40 db(A) @ 1 m 2000 m / 6560 ft IP 65 Natural 420mm x 326mm x 141mm / 16.5 x 12.8 x 5.6 < 14.5 kg / 32.0 lb Wall bracket Transformerless CE EN 50178, EN61000-6-1, EN61000-6-3, EN61000-3-2, EN61000-3-3, AS/NZS 3100 DK 5940, VDE 0126-1-1, G83/1, AS 4777 PVI-2000-OUTD
AURORA UNO
33
34
AURORA UNO
The most common residential inverter is the ideal size for an average-sized family home. This family of single-phase string inverter complements the typical number of rooftop solar panels, allowing home-owners to get the most efficient energy harvesting for the size of the property. This rugged outdoor inverter has been designed as a completely sealed unit to withstand the harshest environmental conditions. One of the key benefits of the Uno family of single-phase inverters is the dual input section to process two strings with independent MPPT especially useful for rooftop installations with two different orientations (ie East and West). The high speed MPPT offers real-time power tracking and improved energy harvesting. The transformerless operation gives the highest efficiency of up to 97.0%. The wide input voltage range makes the inverter suitable to low power installations with reduced string size.
Features
Each inverter is set on specific grid codes which can be selected in the field Single phase output Dual input sections with independent MPP tracking, allows optimal energy harvesting from Wide input range High speed and precise MPPT algorithm for real time power tracking and improved energy
two sub-arrays oriented in different directions harvesting Flat efficiency curves ensure high efficiency at all output levels ensuring consistent and stable performance across the entire input voltage and output power range Outdoor enclosure for unrestricted use under any environmental conditions Integrated DC disconnect switch in compliance with international Standards (-S Version) RS-485 communication interface (for connection to laptop or datalogger) Compatible with PVI-RADIOMODULE for wireless communication with Aurora PVI-DESKTOP
AURORA UNO
35
UNO TRIO
MPPT 1 (DC/DC)
BULK CAPS
INVERTER (DC/AC)
LINE FILTER
IN2.1(+)
IN2.1(+)
MPPT 2 (DC/DC)
PE
IN2
IN2
STANDARD VERSION
(*)Not available in PVI-3.0-TL-OUTD
-S VERSION
RS485 + T/R - T/R RTN DC/DC DSP CONTR. DC/AC DSP CONTR. REMOTE CONTROL +R -R
CONTROL CIRCUIT
PVI-4.2-TL-OUTD
99 98 97 96 95 94 Efficiency [%] 93 92 91 90 89 88 87 86 85 215Vdc 345Vdc 480Vdc
PVI-4.2-TL-OUTD
100,00% 95,00% 90,00% 85,00% 80,00% 75,00% 70,00% 65,00% 60,00% 55,00% 50,00% 45,00% 40,00% 35,00% 30,00% 25,00% 20,00% 15,00% 10,00% 5,00% 480 96,8 96,4 96 95,6 [%] of Rated Power 95,2 94,8 94,4 94 93,6 93,2 92,8 92,4 92 91,6
96 96,4
96,2
96,8
96,4
96 96
94 92
100%
95,2
0%
10%
20%
30%
40%
50%
60%
70%
80%
90%
215
36
AURORA UNO
PARAMETER
Input Side Absolute Maximum DC Input Voltage (Vmax,abs) Start-up DC Input Voltage (Vstart) Operating DC Input Voltage Range (Vdcmin...Vdcmax) Rated DC Input Power (Pdcr) Number of Independent MPPT Maximum DC Input Power for each MPPT (PMPPTmax) DC Input Voltage Range with Parallel Configuration of MPPT at Pacr DC Power Limitation with Parallel Configuration of MPPT DC Power Limitation for each MPPT with Independent Configuration of MPPT at Pacr , max unbalance example Maximum DC Input Current (Idcmax) / for each MPPT (IMPPTmax) Maximum Input Short Circuit Current for each MPPT Number of DC Inputs Pairs for each MPPT DC Connection Type Input Protection Reverse Polarity protection Input Over Voltage Protection for each MPPT - Varistor Photovoltaic Array Isolation Control DC Switch Rating for each MPPT (-S Version) Output Side AC Grid Connection Type Rated AC Power (Pacr) Maximum AC Output Power (Pacmax) Rated AC Grid Voltage (Vac,r) AC Voltage Range Maximum AC Output Current (Iac,max) Rated Output Frequency (fr) Output Frequency Range (fmin...fmax) Nominal Power Factor (Cosphiac,r) Total Current Harmonic Distortion AC Connection Type Output Protection Anti-Islanding Protection Maximum AC Overcurrent Protection Output Overvoltage Protection - Varistor Operating Performance Maximum Efficiency (max) Weighted Efficiency (EURO/CEC) Feed In Power Threshold Stand-by Consumption Communication Wired Local Monitoring Remote Monitoring Wireless Local Monitoring User Interface Environmental Ambient Temperature Range Relative Humidity Noise Emission Maximum Operating Altitude without Derating Physical Environmental Protection Rating Cooling Dimension (H x W x D) Weight Mounting System Safety Isolation Level Marking Safety and EMC Standard Grid Standard Available Products Variants Standard With DC Switch
1. The AC voltage range may vary depending on specific country grid standard 2. Maximum Output Current Limited to 16A for G83/1 version 3. The Frequency range may vary depending on specific country grid standard 4. Ask sales for availability
PVI-3.0-TL-OUTD
PVI-3.6-TL-OUTD
600 V 200 V (adj. 120...350 V) 0.7 x Vstart...580 V 3750 W 2
PVI-4.2-TL-OUTD
4375 W
3000 W 120...530 V 140...530 V Linear Derating From MAX to Null [530VVMPPT580V] 2000 W [200VVMPPT530V] 3000 W [190VVMPPT530V] the other channel: Pdcr-2000W the other channel: Pdcr-3000W [90VVMPPT530V] [112VVMPPT530V] 20.0 A / 10.0 A 32.0 A / 16.0 A 12.5 A 20.0 A 1 2 for MPPT1 and 1 for MPPT2 Tool Free PV Connector WM / MC4 Yes, from limited current source 2 According to local standard 25 A / 600 V Single phase 3600 W 4000 W 230 V 180...264 V(1) 17.2 A (2) 50 Hz 47...53 Hz (3) > 0.995 < 3.5 % Screw terminal block According to local standard 19.0 A 2 (L - N / L - PE) 96.8% 96.0% / 10.0 W < 8.0 W PVI-USB-RS485_232 (opt.), PVI-DESKTOP (opt.) PVI-AEC-EVO (opt.), AURORA-UNIVERSAL (opt.) PVI-DESKTOP (opt.) with PVI-RADIOMODULE (opt.) 16 characters x 2 lines LCD display -25...+60C /-13...140F with derating above 55C/131F 0...100 % condensing < 50 db(A) @ 1 m 2000 m / 6560 ft IP 65 Natural 617mm x 325mm x 222mm / 24.3 x 12.8 x 8.7 17.5 kg / 38.5 lb Wall bracket Transformerless CE EN 50178, AS/NZS3100, AS/NZS 60950, EN61000-6-1, EN61000-6-3, EN61000-3-2, EN61000-3-3 DK 5940, VDE 0126-1-1, G83/1, DK 5940, VDE 0126-1-1, G83/1, DK 5940, VDE 0126-1-1, G59/2, G59/2(4) , EN 50438, RD1663, EN 50438, RD1663, AS 4777 EN 50438, RD1663, AS 4777 AS 4777 PVI-3.0-TL-OUTD PVI-3.0-TL-OUTD-S PVI-3.6-TL-OUTD PVI-3.6-TL-OUTD-S PVI-4.2-TL-OUTD PVI-4.2-TL-OUTD-S
3000 W 3300 W
4200 W 4600 W
14.5 A
20.0 A
16.0 A
22.0 A
AURORA UNO
37
MPPT 1 (DC/DC)
BULK CAPS
INVERTER (DC/AC)
IN1.1(+)
IN1 IN1 LINE FILTER GRID PARALLEL RELAY L1 N L2
IN2.1(+) IN2.2(+) +
+
IN2.1(+)
IN2
MPPT 2 (DC/DC)
IN2
PE
STANDARD VERSION
-S VERSION
RS485 + T/R - T/R RTN DC/DC DSP CONTR. DC/AC DSP CONTR. REMOTE CONTROL +R -R
GROUND FAULT DETECTION
CONTROL CIRCUIT
PVI-4.2-OUTD-US
100 99 98 97
Efficiency, %
96 96,4
PVI-4.2-OUTD-US
100,00% 95,00% 90,00% 85,00% 80,00% 75,00% 97,0 96,2 96,4 70,00% 60,00% 55,00% 50,00% 45,00% 96 40,00% 96 35,00% 30,00% 25,00% 94 95,2 94 92 250 300 345 92 400 MPPT Voltage [V] 95,2 20,00% 15,00% 10,00% 5,00% 480 [%] of Rated Power 65,00%
95,6 95,2 94,8 94,4 94 93,6 93,2 92,8 92,4 92 91,6 96,6 96 97,0
96 95 94 93 92 91 90 0% 200 Vdc 340 Vdc 480 Vdc 10% 20% 30% 40% 50% 60% 70% 80% 90% 100%
92 215
38
AURORA UNO
PARAMETER
Input Side Absolute Maximum DC Input Voltage (Vmax,abs) Start-up DC Input Voltage (Vstart) Operating DC Input Voltage Range (Vdcmin...Vdcmax) Rated DC Input Power (Pdcr) Number of Independent MPPT Maximum DC Input Power for each MPPT (PMPPTmax) DC Input Voltage Range with Parallel Configuration of MPPT at Pacr DC Power Limitation with Parallel Configuration of MPPT DC Power Limitation for each MPPT with Independent Configuration of MPPT at Pacr , max unbalance example Maximum DC Input Current (Idcmax) / for each MPPT (IMPPTmax) Maximum Input Short Circuit Current for each MPPT Number of DC Inputs Pairs for each MPPT DC Connection Type Input Protection Reverse Polarity protection Input Over Voltage Protection for each MPPT - Varistor Photovoltaic Array Isolation Control DC Switch Rating for each MPPT (-S Version) Output Side AC Grid Connection Type Rated AC Power (Pacr) Maximum AC Output Power (Pacmax) Rated AC Grid Voltage (Vac,r) AC Voltage Range Maximum AC Output Current (Iac,max) Rated Output Frequency (fr) Output Frequency Range (fmin...fmax) Nominal Power Factor (Cosphiac,r) Total Current Harmonic Distortion AC Connection Type Output Protection Anti-Islanding Protection Maximum AC Overcurrent Protection Output Overvoltage Protection - Varistor Operating Performance Maximum Efficiency (max) Weighted Efficiency (EURO/CEC) Feed In Power Threshold Stand-by Consumption Communication Wired Local Monitoring Remote Monitoring Wireless Local Monitoring User Interface Environmental Ambient Temperature Range Relative Humidity Noise Emission Maximum Operating Altitude without Derating Physical Environmental Protection Rating Cooling Dimension (H x W x D) Weight Mounting System Safety Isolation Level Marking Safety and EMC Standard Grid Standard Available Products Variants Standard With DC Switch
PVI-3.0-OUTD-US
PVI-3.6-OUTD-US
600 V 200 V (adj. 120...350 V) 0.7 x Vstart...580 V 3750 W 2
PVI-4.2-OUTD-US
4380 W
3000 W 120...530 V 140...530 V Linear Derating From MAX to Null [530VVMPPT580V] 2000 W [200VVMPPT530V] 3000 W [190VVMPPT530V] the other channel: Pdcr-2000W the other channel: Pdcr-3000W [90VVMPPT530V] [112VVMPPT530V] 20.0 A / 10.0 A 32.0 A / 16.0 A 12.5 A 20.0 A 2 (1 on -S Version) Screw terminal block,3 Knock-Outs: 1 or 1 (w/ Ring Red.) Yes, from limited current source 2 GFDI (for use with either Positive or Negative Grounded Arrays) 25 A / 600 V 208 V 240 V 277 V 208 V 240 V 277 V 208 V 240 V 277 V Single phase / Split phase 3000 W 3600 W 4200 W 3000 W 3300 W 3300 W 3600W 4000 W 4000 W 4200 W 4600 W 4600 W 208 V 240 V 277 V 208 V 240 V 277 V 208 V 240 V 277 V 183-228 V 211-264 V 244-304 V 183-228 V 211-264 V 244-304 V 183-228 V 211-264 V 244-304 V 14.5 A 14.5 A 12.0 A 17.2 A 16.0 A 16.0 A 20.0 A 20.0 A 20.0 A 60 Hz 59.3...60.5 Hz > 0.995 < 2% Screw Terminal Block, 3 Knock-Outs: 1 or 1 (w/ Ring Reducer) 208 V 240 V 277 V 208 V 240 V 277 V 208 V 240 V 277 V According to UL 1741/IEE1547 20.0 A 20.0 A 15.0 A 25.0 A 20.0 A 20.0 A 25.0 A 25.0 A 25.0 A 2 (L1 - L2 / L1 - PE) 208 V 240 V 277 V 208 V 240 V 277 V 208 V 240 V 277 V 96.9% 97.0% 97.0% - / 96.0% - / 96.0% - / 96.0% - / 96.0% - / 96.0% - / 96.0% - / 96.0% - / 96.0% - / 96.0% 20.0 W < 8.0 W PVI-USB-RS485_232 (opt.), PVI-DESKTOP (opt.) PVI-AEC-EVO (opt.), AURORA-UNIVERSAL (opt.) PVI-DESKTOP (opt.) with PVI-RADIOMODULE (opt.) 16 characters x 2 lines LCD display -25...+60C (-13...+140F) with derating above 55C (131F) 0...100 % condensing < 50 db(A) @ 1 m 2000 m / 6560 ft NEMA 4X Natural 617mm x 325mm x 222mm / 24.3 x 12.8 x 8.7 859mm x 325mm x 222mm / 33.8 x 12.8 x 8.7 (-S Version) < 17.5 kg / 38,5 lb < 21.3 kg / 47.3 lb (-S version) Wall bracket Transformerless cCSAus UL 1741, CSA - C22.2 N. 107.1-01 IEEE 1547 PVI-3.0-OUTD-US PVI-3.0-OUTD-S-US PVI-3.6-OUTD-US PVI-3.6-OUTD-S-US PVI-4.2-OUTD-US PVI-4.2-OUTD-S-US
AURORA UNO
39
PVI-3.8-I PVI-4.6-I
40
AURORA UNO
This isolated inverter is optimized for use in residential applications requiring PV array grounding, such as some thin-film modules. This inverter has also been designed to serve all countries and regions with specific field-configurable set-ups available for all major country grid codes and display languages. The 3.8 and 4.6kW isolated inverters have all the usual Aurora benefits including dual input section to process two strings with independent MPPT, high speed and precise MPPT algorithm for real-time power tracking and energy harvesting, as well as regular high performance efficiencies of up to 96.9%. The wide input voltage range makes the inverter suitable to low power installations with reduced string size. Its high frequency isolated topology allows this unit to be lightweight and compact in size to help with transportation and installation. This rugged outdoor inverter has been designed as a completely sealed unit to withstand the harshest environmental conditions.
Features
Each inverter is set on specific grid codes which can be selected in the field Single phase output Night Wake up button to access energy harvesting data and error log Dual input sections with independent MPP tracking, allows optimal energy harvesting from
two sub-arrays oriented in different directions Wide input range High speed and precise MPPT algorithm for real time power tracking and improved energy harvesting Flat efficiency curves ensure high efficiency at all output levels ensuring consistent and stable performance across the entire input voltage and output power range Outdoor enclosure for unrestricted use under any environmental conditions RS-485 communication interface (for connection to laptop or datalogger) Compatible with PVI-RADIOMODULE for wireless communication with Aurora PVI-DESKTOP
AURORA UNO
41
UNO TRIO
IN1.1(+)
+
IN1.2(+)
MPPT 1 (DC/DC)
HF TRANSFORMER
BULK CAPS
INVERTER (DC/AC)
IN1
IN1.1(-) IN1.2(-)
IN2.1(+) IN2.2(+) +
IN2.1(+) IN2.2(+)
MPPT 2 (DC/DC)
HF TRANSFORMER
PE
IN2
IN2
STANDARD VERSION
-S VERSION
RS485
+R -R
ALARM
PVI-3.8-I-OUTD
100 99 98 97 96 95 94 93 92 91 90 0% 100 99 98 97
Efficiency, %
PVI-4.6-I-OUTD
Efficiency, %
96 95 94 93 92 91 90 0%
200 Vdc 340 Vdc 416 Vdc 10% 20% 30% 40% 50% 60% 70% 80% 90% 100%
200 Vdc 340 Vdc 416 Vdc 10% 20% 30% 40% 50% 60% 70% 80% 90% 100%
42
AURORA UNO
PARAMETER
Input Side Absolute Maximum DC Input Voltage (Vmax,abs) Start-up DC Input Voltage (Vstart) Operating DC Input Voltage Range (Vdcmin...Vdcmax) Rated DC Input Power (Pdcr) Number of Independent MPPT (4) Maximum DC Input Power for each MPPT (PMPPTmax) DC Input Voltage Range with Parallel Configuration of MPPT at Pacr DC Power Limitation with Parallel Configuration of MPPT DC Power Limitation for each MPPT with Independent Configuration of MPPT at Pacr , max unbalance example Maximum DC Input Current (Idcmax) / for each MPPT (IMPPTmax) Maximum Input Short Circuit Current for each MPPT Number of DC Inputs Pairs for each MPPT DC Connection Type Input Protection Reverse Polarity protection Input Over Voltage Protection for each MPPT - Varistor Photovoltaic Array Isolation Control DC Switch Rating for each MPPT (-S Version) Output Side AC Grid Connection Type Rated AC Power (Pacr) Maximum AC Output Power (Pacmax) Rated AC Grid Voltage (Vac,r) AC Voltage Range Maximum AC Output Current (Iac,max) Rated Output Frequency (fr) Output Frequency Range (fmin...fmax) Nominal Power Factor (Cosphiac,r) Total Current Harmonic Distortion AC Connection Type Output Protection Anti-Islanding Protection Maximum AC Overcurrent Protection Output Overvoltage Protection - Varistor Operating Performance Maximum Efficiency (max) Weighted Efficiency (EURO/CEC) Feed In Power Threshold Stand-by Consumption Communication Wired Local Monitoring Remote Monitoring Wireless Local Monitoring User Interface Environmental Ambient Temperature Range Relative Humidity Noise Emission Maximum Operating Altitude without Derating Physical Environmental Protection Rating Cooling Dimension (H x W x D) Weight Mounting System Safety Isolation Level Marking Safety and EMC Standard Grid Standard Available Products Variants Standard With DC Switch
1. The AC voltage range may vary depending on specific country grid standard 2. Maximum Output Current Limited to 16A for G83/1 version 3. The Frequency range may vary depending on specific country grid standard 4. Independent MPPT just with negative ground
PVI-3.8-I-OUTD
520 V 200 V (adj. 120...350 V) 0.7 x Vstart...520 V 2 3000 W
PVI-4.6-I-OUTD
4000 W
4800 W
160...470 V 180...470 V Linear Derating From MAX to Null Linear Derating From MAX to Null [470VVMPPT520V] [470VVMPPT520V] 3000 W [210VVMPPT470V] the other channel: 3000 W [210VVMPPT470V] the other channel: Pdcr-3000W [90VVMPPT470V] Pdcr-3000W [130VVMPPT470V] 25.0 A / 12.5 A 28.0 A / 14.0 A 22.0 A 2 Tool Free PV Connector WM / MC4 Yes, from limited current source 2 According to local standard 25 A / 600 V Single phase 3800 W 4200 W 230 V 180...264 V (1) 18.2 A (2) 50 Hz 47...53 Hz (3) > 0.995 (adj. 0.95) < 2% Screw terminal block According to local standard 20.0 A 2 (L - N / L - PE) 96.8% - / 96.5% 24.0 W < 8.0 W PVI-USB-RS485_232 (opt.), PVI-DESKTOP (opt.) PVI-AEC-EVO (opt.), AURORA-UNIVERSAL (opt.) PVI-DESKTOP (opt.) with PVI-RADIOMODULE (opt.) 16 characters x 2 lines LCD display -25...+60C (-13...+ 140F) -25...+60C (-13...+ 140F) with derating above 50C (122F) 0...100 % condensing < 50 db(A) @ 1 m 2000 m / 6560 ft 25.0 A 22.5 A 4600 W 5000 W
IP 65 Natural 712mm x 325mm x 222mm / 28.0 x 12.8 x 8.7 < 24.0 kg / 53.0 lb Wall bracket HF Transformer CE EN 50178, AS/NZS3100, AS/NZS 60950, EN61000-6-1, EN61000-6-3, EN61000-3-11, EN61000-3-12 Enel Guideline, VDE 0126-1-1, G83/1, G59/2, EN 50438, RD1663, AS 4777 PVI-3.8-I-OUTD PVI-3.8-I-OUTD-S PVI-4.6-I-OUTD PVI-4.6-I-OUTD-S
AURORA UNO
43
IN1.1(+)
*
MPPT 1 (DC/DC)
HF TRANSFORMER
BULK CAPS
INVERTER (DC/AC)
IN1.2(+)
IN1 IN1 LINE FILTER GRID PARALLEL RELAY L1 N L2
IN1.1(-) IN1.2(-)
IN2.1(+) IN2.2(+) +
IN2.1(+) IN2.2(+)
*
MPPT 2 (DC/DC)
HF TRANSFORMER
IN2
IN2
PE
STANDARD VERSION
-S VERSION-NG
* if -PG version, switch is on negative polarity.
RS485 + T/R - T/R RTN DC/DC DSP CONTR. DC/AC DSP CONTR. REMOTE CONTROL +R -R
GROUND FAULT DETECTION
CONTROL CIRCUIT
PVI-3.8-I-OUTD-US
100 99 98 97 96 95 94 93 92 91 90 0% 100 99 98 97
Efficiency, %
PVI-4.6-I-OUTD-US
Efficiency, %
96 95 94 93 92 91 90 0%
200 Vdc 340 Vdc 416 Vdc 10% 20% 30% 40% 50% 60% 70% 80% 90% 100%
200 Vdc 340 Vdc 416 Vdc 10% 20% 30% 40% 50% 60% 70% 80% 90% 100%
44
AURORA UNO
PARAMETER
Input Side Absolute Maximum DC Input Voltage (Vmax,abs) Start-up DC Input Voltage (Vstart) Operating DC Input Voltage Range (Vdcmin...Vdcmax) Rated DC Input Power (Pdcr) Number of Independent MPPT (4) Maximum DC Input Power for each MPPT (PMPPTmax) DC Input Voltage Range with Parallel Configuration of MPPT at Pacr DC Power Limitation with Parallel Configuration of MPPT DC Power Limitation for each MPPT with Independent Configuration of MPPT at Pacr , max unbalance example Maximum DC Input Current (Idcmax) / for each MPPT (IMPPTmax) Maximum Input Short Circuit Current for each MPPT Number of DC Inputs Pairs for each MPPT DC Connection Type Input Protection Reverse Polarity protection Input Over Voltage Protection for each MPPT - Varistor Photovoltaic Array Isolation Control DC Switch Rating for each MPPT (-S Version) Output Side AC Grid Connection Type Rated AC Power (Pacr) Maximum AC Output Power (Pacmax) Rated AC Grid Voltage (Vac,r) AC Voltage Range Maximum AC Output Current (Iac,max) Rated Output Frequency (fr) Output Frequency Range (fmin...fmax) Nominal Power Factor (Cosphiac,r) Total Current Harmonic Distortion AC Connection Type Output Protection Anti-Islanding Protection Maximum AC Overcurrent Protection Output Overvoltage Protection - Varistor Operating Performance Maximum Efficiency (max) Weighted Efficiency (EURO/CEC) Feed In Power Threshold Stand-by Consumption Communication Wired Local Monitoring Remote Monitoring Wireless Local Monitoring User Interface Environmental Ambient Temperature Range Relative Humidity Noise Emission Maximum Operating Altitude without Derating Physical Environmental Protection Rating Cooling Dimension (H x W x D) Weight Mounting System Safety Isolation Level Marking Safety and EMC Standard Grid Standard Available Products Variants Standard - Positive Ground Standard - Negative Ground With DC Switch - Positive Ground With DC Switch - Negative Ground
4. Independent MPPT just with negative ground
PVI-3.8-I-OUTD-US
PVI-4.6-I-OUTD-US
4000 W
4800 W
Linear Derating From MAX to Null [470VVMPPT520V] 3000 W [240VVMPPT470V] the other channel: Pdcr-3000W [90VVMPPT470V] 25.0 A / 12.5 A 15.6 A
Linear Derating From MAX to Null [470VVMPPT520V] 3000 W [210VVMPPT470V] the other channel: Pdcr-3000W [130VVMPPT470V] 28.0 A / 14.0 A 17.0 A
2 Screw terminal block, 3 Knock-Outs: or 1 (w/ Ring Red.) Yes, from limited current source 2 GFDI (for use with either Positive or Negative Grounded Arrays) 25 A / 600 V 208 V 240 V 277 V 208 V 240 V Single phase / Split phase 3300 W 3800 W 4600 W 3300 W 3800W 4200 W 5000 W 5000 W 208 V 240 V 277 V 208 V 240 V 183...228 V 211...264 V 244...304 V 183...228 V 211...264 V 16.0 A 16.0 A 16.0 A 23.0 A 20.0 A 60 Hz 59.3...60.5 Hz > 0.995 < 2% Screw terminal block, 3 Knock-Outs: or 1 (w/ Ring Red.) 208 V 240 V 277 V 208 V 240 V According to UL 1741/IEE1547 20.0 A 20.0 A 20.0 A 30.0 A 25.0 A 2 (L1 - L2 / L1 - PE) 208 V 240 V 277 V 208 V 240 V 96.9% 96.9% - / 96.0% - / 96.5% - / 96.5% - / 96.0% - / 96.5% 24.0 W < 8.0 W PVI-USB-RS485_232 (opt.), PVI-DESKTOP (opt.) PVI-AEC-EVO (opt.), AURORA-UNIVERSAL (opt.) PVI-DESKTOP (opt.) with PVI-RADIOMODULE (opt.) 16 characters x 2 lines LCD display -25...+60C (-13...+ 140F) -25...+60C (-13...+ 140F) with derating above 50C (122F) 0...100 % condensing < 50 db(A) @ 1 m 2000 m / 6560 ft
277 V
NEMA 4X Natural 712mm x 325mm x 222mm / 28.0 x 12.8 x 8.7 952mm x 325mm x 222mm / 37.5 x 12.8 x 8.7 (-S Version) < 24.0 kg / 53.0 lb < 28.0 kg / 61.0 lb (-S version) Wall bracket HF Transformer cCSAus UL 1741, CSA - C22.2 N. 107.1-01 IEEE 1547 PVI-3.8-I-OUTD-US-PG PVI-3.8-I-OUTD-US-NG PVI-3.8-I-OUTD-US-S-PG PVI-3.8-I-OUTD-US-S-NG PVI-4.6-I-OUTD-US-PG PVI-4.6-I-OUTD-US-NG PVI-4.6-I-OUTD-US-S-PG PVI-4.6-I-OUTD-US-S-NG AURORA UNO 45
PVI-5000-TL PVI-6000-TL
GENERAL SPECIFICATIONS OUTDOOR MODELS
PVI-5000-TL-OUTD PVI-6000-TL-OUTD PVI-5000-OUTD-US PVI-6000-OUTD-US
46
AURORA UNO
Designed for residential and small commercial PV installations, this inverter fills a specific niche in the Aurora product line to cater for those installations producing between 5kW and 20kW. This inverter has all the usual Aurora benefits, including dual input section to process two strings with independent MPPT, high speed and precise MPPT algorithm for real-time power tracking and energy harvesting, as well as transformerless operation for high performance efficiencies of up to 97.1%. The wide input voltage range makes the inverter suitable to low power installations with reduced string size. This outdoor inverter has been designed as a completely sealed unit to withstand the harshest environmental conditions.
Features
Each inverter is set on specific grid codes which can be selected in the field Single phase output Dual input sections with independent MPP tracking, allows optimal energy harvesting
from two sub-arrays oriented in different directions Wide input range High speed and precise MPPT algorithm for real time power tracking and improved energy harvesting Flat efficiency curves ensure high efficiency at all output levels ensuring consistent and stable performance across the entire input voltage and output power range Outdoor enclosure for unrestricted use under any environmental conditions RS-485 communication interface (for connection to laptop or datalogger) Compatible with PVI-RADIOMODULE for wireless communication with Aurora PVI-DESKTOP
AURORA UNO
47
UNO TRIO
MPPT 1 (DC/DC)
BULK CAPS
INVERTER (DC/AC)
LINE FILTER
IN2.1(+) IN2.2(+) +
IN2.1(+) IN2.2(+) +
+
MPPT 2 (DC/DC)
PE
IN2
IN2
STANDARD VERSION
-S VERSION
RS485 + T/R - T/R RTN DC/DC DSP CONTR. DC/AC DSP CONTR. REMOTE CONTROL +R -R
CONTROL CIRCUIT
PVI-5000-TL-OUTD
100 99 98 97 96 Efficiency, % 95 94 93 250 Vdc 92 345 Vdc 91 90 0% 10% 20% 30% 40% 50% 60% 70% 80% 90% 100% % of Rated Output Power 480 Vdc 91 90 0% 10% 20% 92 Efficiency, % 100 99 98 97 96 95 94 93
PVI-6000-TL-OUTD
30%
40%
50%
60%
70%
80%
90%
100%
48
AURORA UNO
PARAMETER
Input Side Absolute Maximum DC Input Voltage (Vmax,abs) Start-up DC Input Voltage (Vstart) Operating DC Input Voltage Range (Vdcmin...Vdcmax) Rated DC Input Power (Pdcr) Number of Independent MPPT Maximum DC Input Power for each MPPT (PMPPTmax) DC Input Voltage Range with Parallel Configuration of MPPT at Pacr DC Power Limitation with Parallel Configuration of MPPT DC Power Limitation for each MPPT with Independent Configuration of MPPT at Pacr , max unbalance example Maximum DC Input Current (Idcmax) / for each MPPT (IMPPTmax) Maximum Input Short Circuit Current for each MPPT Number of DC Inputs Pairs for each MPPT DC Connection Type Input Protection Reverse Polarity protection Input Over Voltage Protection for each MPPT - Varistor Photovoltaic Array Isolation Control DC Switch Rating for each MPPT (-S Version) Output Side AC Grid Connection Type Rated AC Power (Pacr) Maximum AC Output Power (Pacmax) Rated AC Grid Voltage (Vac,r) AC Voltage Range Maximum AC Output Current (Iac,max) Rated Output Frequency (fr) Output Frequency Range (fmin...fmax) Nominal Power Factor (Cosphiac,r) Total Current Harmonic Distortion AC Connection Type Output Protection Anti-Islanding Protection Maximum AC Overcurrent Protection Output Overvoltage Protection - Varistor Operating Performance Maximum Efficiency (max) Weighted Efficiency (EURO/CEC) Feed In Power Threshold Stand-by Consumption Communication Wired Local Monitoring Remote Monitoring Wireless Local Monitoring User Interface Environmental Ambient Temperature Range Relative Humidity Noise Emission Maximum Operating Altitude without Derating Physical Environmental Protection Rating Cooling Dimension (H x W x D) Weight Mounting System Safety Isolation Level Marking Safety and EMC Standard Grid Standard Available Products Variants Standard With DC Switch
1. The AC voltage range may vary depending on specific country grid standard 2. The Frequency range may vary depending on specific country grid standard 3. Limited to 4600 W for Germany
PVI-5000-TL-OUTD
PVI-6000-TL-OUTD
4800 W
6200 W
150...530 V 180...530 V Linear Derating From MAX to Null [530VVMPPT580V] 4000 W [220VVMPPT530V] the other channel: Pdcr-4000W [90VVMPPT530V] 4000 W [220VVMPPT530V] the other channel: Pdcr-4000W [120VVMPPT530V]
36.0 A / 18.0 A 22.0 A 2 Tool Free PV Connector WM / MC4 Yes, from limited current source 2 According to local standard 25 A / 600 V Single phase
5000 W 5000 W (3) 230 V 180...264 V (1) 25.0 A 50 Hz 47...53 Hz (2) > 0.995 < 3.5% Screw terminal block According to local standard 32.0 A 2 (L - N / L - PE) 97.0% 96.4% / 10.0 W < 8.0 W
6000 W 6000 W
30.0 A
40.0 A
PVI-USB-RS485_232 (opt.), PVI-DESKTOP (opt.) PVI-AEC-EVO (opt.), AURORA-UNIVERSAL (opt.) PVI-DESKTOP (opt.) with PVI-RADIOMODULE (opt.) 16 characters x 2 lines LCD display -25...+60C (-13...+ 140F) with derating above 50C (122F) 0...100% condensing <50 db(A) @ 1 m 2000 m / 6560 ft IP 65 Natural 810mm x 325mm x 222mmm / 31.9 x 12.8 x 8.7 < 26.0 kg / 57.3 lb Wall bracket Transformerless CE EN 50178, AS/NZS3100, AS/NZS 60950, EN61000-6-1, EN61000-6-3, EN61000-3-2, EN61000-3-3 DK 5940, VDE 0126-1-1, G59/2, EN 50438, RD1663, AS 4777 PVI-5000-TL-OUTD PVI-5000-TL-OUTD-S PVI-6000-TL-OUTD PVI-6000-TL-OUTD-S
AURORA UNO
49
MPPT 1 (DC/DC)
BULK CAPS
INVERTER (DC/AC)
IN2(+)
MPPT 2 (DC/DC)
IN2 IN2(-)
IN2
-S VERSION
RS485 + T/R - T/R RTN DC/DC DSP CONTR. DC/AC DSP CONTR. REMOTE CONTROL +R -R
GROUND FAULT DETECTION
CONTROL CIRCUIT
PVI-6000-OUTD-US
PVI-6000-OUTD-US
100 99 98 97 Efficiency, % 96 95 94 93 92 91 90 250 Vdc 345 Vdc 480 Vdc 0% 10% 20% 30% 40% 50% 60% 70% 80% 90% 100%
97,1 96,8 96,5 96,2 95,9 [%] of Rated Power 95,6 95,3 95 94,7 94,4 94,1 93,8 93,5 93,2 92,9 92,6
400
300
10%
250 100%
50
AURORA UNO
PARAMETER
Input Side Absolute Maximum DC Input Voltage (Vmax,abs) Start-up DC Input Voltage (Vstart) Operating DC Input Voltage Range (Vdcmin...Vdcmax) Rated DC Input Power (Pdcr) Number of Independent MPPT Maximum DC Input Power for each MPPT (PMPPTmax) DC Input Voltage Range with Parallel Configuration of MPPT at Pacr DC Power Limitation with Parallel Configuration of MPPT DC Power Limitation for each MPPT with Independent Configuration of MPPT at Pacr , max unbalance example Maximum DC Input Current (Idcmax) / for each MPPT (IMPPTmax) Maximum Input Short Circuit Current for each MPPT Number of DC Inputs Pairs for each MPPT DC Connection Type Input Protection Reverse Polarity protection Input Over Voltage Protection for each MPPT - Varistor Photovoltaic Array Isolation Control DC Switch Rating for each MPPT (-S Version) Output Side AC Grid Connection Type Rated AC Power (Pacr) Maximum AC Output Power (Pacmax) Rated AC Grid Voltage (Vac,r) AC Voltage Range Maximum AC Output Current (Iac,max) Rated Output Frequency (fr) Output Frequency Range (fmin...fmax) Nominal Power Factor (Cosphiac,r) Total Current Harmonic Distortion AC Connection Type Output Protection Anti-Islanding Protection Maximum AC Overcurrent Protection Output Overvoltage Protection - Varistor Operating Performance Maximum Efficiency (max) Weighted Efficiency (EURO/CEC) Feed In Power Threshold Stand-by Consumption Communication Wired Local Monitoring Remote Monitoring Wireless Local Monitoring User Interface Environmental Ambient Temperature Range Relative Humidity Noise Emission Maximum Operating Altitude without Derating Physical Environmental Protection Rating Cooling Dimension (H x W x D) Weight Mounting System Safety Isolation Level Marking Safety and EMC Standard Grid Standard Available Products Variants With DC Switch
PVI-5000-OUTD-US
PVI-6000-OUTD-US
6180 W 2 4000 W 200...530 V Linear Derating From MAX to Null [530VVMPPT580V] 4000 W [230VVMPPT530V] 4000 W [225VVMPPT530V] the other channel: Pdcr-4000W the other channel: Pdcr-4000W [90VVMPPT530V] [120VVMPPT530V] 36.0 A / 18.0 A 22.0 A 1 Screw Terminal Block, 3 Knock-Outs: 1 or 1 (w/ Ring Reducer) Yes, from limited current source 2 GFDI (for use with either Positive or Negative Grounded Arrays) 25 A / 600 V 240 V 277 V 208 V 240 V Single phase / Split phase 5000 W 6000 W 5000 W 6000 W 240 V 277 V 208 V 240 V 211...264 V 244...304 V 183...228 V 211...264 V 23.0 A 20.0 A 30.0 A 28.0 A 60 Hz 59.3...60.5 Hz > 0.995 < 2% Screw terminal block 240 V 277 V 208 V 240 V According to UL 1741/IEE1547 30.0 A 25.0 A 40.0 A 35.0 A 2 (L1 - L2 / L1 - PE) 240 V 277 V 208 V 240 V 97.1% 97.1% 96.5% 96.5% 96.0% 96.5% 20.0 W < 8.0 W PVI-USB-RS485_232 (opt.), PVI-DESKTOP (opt.) PVI-AEC-EVO (opt.), AURORA-UNIVERSAL (opt.) PVI-DESKTOP (opt.) with PVI-RADIOMODULE (opt.) 16 characters x 2 lines LCD display -25...+60C (-13...+ 140F) with derating above 50C (122F) 0...100% condensing <50 db(A) @ 1 m 2000 m / 6560 ft IP 65 Natural 1052mm x 325mm x222mmm / 41.4 x 12.8 x 8.7 < 27.0 kg / 59.5 lb Wall bracket Transformerless cCSAus UL 1741, CSA - C22.2 N. 107.1-01 IEEE 1547 PVI-5000-OUTD-US PVI-6000-OUTD-US
5150 W
208 V
277 V
AURORA UNO
51
52
AURORA TRIO
TRIO
AURORA TRIO
53
UNO TRIO
PVI-10.0-I PVI-12.0-I
GENERAL SPECIFICATIONS OUTDOOR MODELS
PVI-10.0-I-OUTD-400 PVI-10.0-I-OUTD-US-208 PVI-10.0-I-OUTD-US-480 PVI-10.0-I-OUTD-CAN-600 PVI-12.0-I-OUTD-400 PVI-12.0-I-OUTD-US-480 PVI-12.0-I-OUTD-CAN-600
-S2 version
-S version
Designed for commercial usage, this three-phase inverter is highly unique in its ability to control the performance of the PV panels, especially during periods of variable weather conditions. This device has two independent MPPTs and efficiency ratings of up to 97.3%. The input voltage range makes the inverter suitable to installations with reduced string size. The HF isolation allows positive or negative ground configuration. It is available with an optional fully-integrated DC and AC disconnect (-S2 version). The unit is free of electrolytic capacitors, leading to a longer product lifetime.
Features
Electrolyte-free power converter to further increase the life expectancy and long term reliability True three-phase bridge topology for DC/AC output converter Each inverter is set on specific grid codes which can be selected in the field Night Wake up button to access energy harvesting data and error log Dual input sections with independent MPP tracking, allows optimal energy harvesting from two
sub-arrays oriented in different directions High speed and precise MPPT algorithm for real time power tracking and improved energy harvesting Flat efficiency curves ensure high efficiency at all output levels ensuring consistent and stable performance across the entire input voltage and output power range Outdoor enclosure for unrestricted use under any environmental conditions Integrated DC disconnect switch in compliance with international Standards (-S and -S2 version) RS-485 communication interface (for connection to laptop or datalogger) Compatible with PVI-RADIOMODULE for wireless communication with Aurora PVI-DESKTOP
AURORA TRIO
55
UNO TRIO
IN1.1(+) IN1.2(+)
(1)
MPPT 1 (DC/DC)
HF TRANSFORMER
BULK CAPS
INVERTER (DC/AC)
L1 L2 L3 N
IN2.1(+) IN1.2(+) +
IN2.1(+) IN2.2(+)
(1)
MPPT 2 (DC/DC)
HF TRANSFORMER
PE
IN2 IN2
STANDARD VERSION
-S VERSION
RS485 IN1.1(+) IN1.2(+) IN1.3(+) + T/R - T/R RTN DC/DC DSP CONTR. GROUND FAULT DETECTION DC/AC DSP CONTR. REMOTE CONTROL +R -R
(1) (1)
(1) (1)
-S2 VERSION-NG
PVI-10.0-I-OUTD
100 99 98 97 96 Efficiency, % Efficiency, % 95 94 93
220 Vdc
PVI-12.0-I-OUTD
100 99 98 97 96 95 94 93
250 Vdc
92 91 90
90%
100%
0%
10%
20%
30%
40%
50%
60%
70%
80%
90%
100%
56
AURORA TRIO
PARAMETER
Input Side Absolute Maximum DC Input Voltage (Vmax,abs) Start-up DC Input Voltage (Vstart) Operating DC Input Voltage Range (Vdcmin...Vdcmax) Rated DC Input Power (Pdcr) Number of Independent MPPT (4) Maximum DC Input Power for each MPPT (PMPPTmax) DC Input Voltage Range with Parallel Configuration of MPPT at Pacr DC Power Limitation with Parallel Configuration of MPPT DC Power Limitation for each MPPT with Independent Configuration of MPPT at Pacr , max unbalance example Maximum DC Input Current (Idcmax) / for each MPPT (IMPPTmax) Maximum Input Short Circuit Current for each MPPT Number of DC Inputs Pairs for each MPPT DC Connection Type Input Protection Reverse Polarity protection Input Over Voltage Protection for each MPPT - Varistor Photovoltaic Array Isolation Control DC Switch Rating for each MPPT (-S Version) Fuse Rating (-FS Version) Output Side AC Grid Connection Type Rated AC Power (Pacr) Maximum AC Output Power (Pacmax) Rated AC Grid Voltage (Vac,r) AC Voltage Range Maximum AC Output Current (Iac,max) Rated Output Frequency (fr) Output Frequency Range (fmin...fmax) Nominal Power Factor (Cosphiac,r) Total Current Harmonic Distortion AC Connection Type Output Protection Anti-Islanding Protection Maximum AC Overcurrent Protection Output Overvoltage Protection - Varistor Operating Performance Maximum Efficiency (max) Weighted Efficiency (EURO/CEC) Feed In Power Threshold Stand-by Consumption Communication Wired Local Monitoring Remote Monitoring Wireless Local Monitoring User Interface Environmental Ambient Temperature Range Relative Humidity Noise Emission Maximum Operating Altitude without Derating Physical Environmental Protection Rating Cooling Dimension (H x W x D) Weight Mounting System Safety Isolation Level Marking Safety and EMC Standard Grid Standard Available Products Variants Standard With DC Switch
1. The AC voltage range may vary depending on specific country grid standard 2. The Frequency range may vary depending on specific country grid standard 3. Limited to 10000 W for Benelux 4. Independent MPPT just with negative ground
PVI-10.0-I-OUTD-400
PVI-12.0-I-OUTD-400
10500 W
12300 W
220...470 V 250...470 V Linear Derating From MAX to Null [470VVMPPT520V] 6800 W [275VVMPPT470V] 6800 W [285VVMPPT470V] the other channel: Pdcr-6800W the other channel: Pdcr-6800W [155VVMPPT470V] [220VVMPPT470V] 48.0 A / 24.0 A 50.0 A / 25.0 A 29.0 A 2 Tool Free PV Connector WM / MC4 Yes, from limited current source 2 According to local standard 32 A / 600 V Not applicable Trifase (/Y) 10000 W 11000 W (3) 400 V 320...480 V (1) 16.0 A 50 Hz 47...53 Hz (2) > 0.995 (adj. 0.9) < 2% Screw terminal block According to local standard 20.0 A 3 plus gas arrester 97.3% 97.0% / 30 W <8W PVI-USB-RS485_232 (opt.), PVI-DESKTOP (opt.) PVI-AEC-EVO (opt.), AURORA-UNIVERSAL (opt.) PVI-DESKTOP (opt.) with PVI-RADIOMODULE (opt.) 16 characters x 2 lines LCD display -25...+60C /-13...140F -25...+60C /-13...140F with derating above 50C/122F with derating above 45C/113F 0...100% condensing < 50 db(A) @ 1 m 2000 m / 6560 ft IP 65 Natural 716mm x 645mm x 222mm / 28.2 x 25.4 x 8.7 < 45.8 kg / 99.0 lb Wall bracket HF transformer CE EN 50178, AS/NZS3100, AS/NZS 60950, EN61000-6-1, EN61000-6-3, EN61000-3-11, EN61000-3-12 Enel Guideline, VDE 0126-1-1, G59/2, EN 50438, RD1663, AS 4777 PVI-10.0-I-OUTD-400 PVI-10.0-I-OUTD-S-400 PVI-12.0-I-OUTD-400 PVI-12.0-I-OUTD-S-400 18.0 A 12000 W 12500 W
AURORA TRIO
57
PARAMETER
Input Side Absolute Maximum DC Input Voltage (Vmax,abs) Start-up DC Input Voltage (Vstart) Operating DC Input Voltage Range (Vdcmin...Vdcmax) Rated DC Input Power (Pdcr) Number of Independent MPPT (4) Maximum DC Input Power for each MPPT (PMPPTmax) DC Input Voltage Range with Parallel Configuration of MPPT at Pacr DC Power Limitation with Parallel Configuration of MPPT DC Power Limitation for each MPPT with Independent Configuration of MPPT at Pacr , max unbalance example Maximum DC Input Current (Idcmax) / for each MPPT (IMPPTmax) Maximum Input Short Circuit Current for each MPPT Number of DC Inputs Pairs for each MPPT DC Connection Type Input Protection Reverse Polarity protection Input Over Voltage Protection for each MPPT - Varistor Photovoltaic Array Isolation Control DC Switch Rating for each MPPT (-S Version) Fuse Rating (-FS Version) Output Side AC Grid Connection Type Rated AC Power (Pacr) Maximum AC Output Power (Pacmax) Rated AC Grid Voltage (Vac,r) AC Voltage Range Maximum AC Output Current (Iac,max) Rated Output Frequency (fr) Output Frequency Range (fmin...fmax) Nominal Power Factor (Cosphiac,r) Total Current Harmonic Distortion AC Connection Type Output Protection Anti-Islanding Protection Maximum AC Overcurrent Protection Output Overvoltage Protection - Varistor Operating Performance Maximum Efficiency (max) Weighted Efficiency (EURO/CEC) Feed In Power Threshold Stand-by Consumption Communication Wired Local Monitoring Remote Monitoring Wireless Local Monitoring User Interface Environmental Ambient Temperature Range Relative Humidity Noise Emission Maximum Operating Altitude without Derating Physical Environmental Protection Rating Cooling Dimension (H x W x D) Weight Mounting System Safety Isolation Level Marking Safety and EMC Standard Grid Standard Available Products Variants Standard - Positive Ground Standard - Negative Ground With DC Switch - Positive Ground With DC Switch - Negative Ground With AC and DC Switches - Positive Ground With AC and DC Switches - Negative Ground 58 AURORA TRIO
PVI-10.0-I-OUTDUS-208
PVI-10.0-I-OUTDUS-480
PVI-10.0-I-OUTDCAN-600
520 V 200 V (adj. 120...350 V) 0.7 x Vstart...520 V 10500 W 2 6800 W 220...470 V Linear Derating From MAX to Null [470VVMPPT520V] 6800 W [285VVMPPT470V] 6800 W [285VVMPPT470V] 6800 W [285VVMPPT470V] the other channel: Pdcrthe other channel: Pdcrthe other channel: Pdcr-6800W 6800W [155VVMPPT470V] 6800W [220VVMPPT470V] [155VVMPPT470V] 48.0 A / 24.0 A 29.0 A 2 (3 on -S2 Version) Screw Terminal Block, 3 Knock-Outs: or 1 /w/ring red.) Yes, from limited current source 2 GFDI (for use with either Positive or Negative Grounded Arrays) 32 A / 600 V 12 A or 15 A / 600 V (1) Trifase (/Y) 10000 W 11000 W 480 V 422...528 V 14.0 A 60 Hz 59.3...60.5 Hz > 0.995 < 2% Screw Terminal Block, 3 Knock-Outs: According to UL 1741/IEE1547 20.0 A 3 plus gas arrester 97.3% - / 97.0% 30 W <8W PVI-USB-RS485_232 (opt.), PVI-DESKTOP (opt.) PVI-AEC-EVO (opt.), AURORA-UNIVERSAL (opt.) PVI-DESKTOP (opt.) with PVI-RADIOMODULE (opt.) 16 characters x 2 lines LCD display -25...+60C /-13...140F -25...+60C /-13...140F -25...+60C /-13...140F with derating above 40C/104F with derating above 50C/122F with derating above 45C/113F 0...100% condensing < 50 db(A) @ 1 m 2000 m / 6560 ft NEMA 4X Natural 716mm x 645mm x 222mm / 28.2 x 25.4 x 8.7 958mm x 645mm x 222mm / 37.7 x 25.4 x 8.7 (-S/-S2 version) < 45.8 kg / 99.0 lb < 48.5 kg / 107 lb (-S Version) < 51.7 / 114 lb (-S2 Version) Wall bracket HF transformer cCSAus UL 1741, CSA - C22.2 N. 107.1-01 IEEE 1547 PVI-10.0-I-OUTD-US-208-PG PVI-10.0-I-OUTD-US-208-NG PVI-10.0-I-OUTD-S-US-208-PG PVI-10.0-I-OUTD-S-US-208-NG PVI-10.0-I-OUTD-S2-US-208-PG PVI-10.0-I-OUTD-S2-US-208-NG PVI-10.0-I-OUTD-US-480-PG PVI-10.0-I-OUTD-US-480-NG PVI-10.0-I-OUTD-S-US-480-PG PVI-10.0-I-OUTD-S-US-480-NG PVI-10.0-I-OUTD-S2-US-480-PG PVI-10.0-I-OUTD-S2-US-480-NG PVI-10.0-I-OUTD-CAN-600-PG PVI-10.0-I-OUTD-CAN-600-NG PVI-10.0-I-OUTD-S-CAN-600-PG PVI-10.0-I-OUTD-S-CAN-600-NG PVI-10.0-I-OUTD-S2-CAN-600-PG PVI-10.0-I-OUTD-S2-CAN-600-NG
1. Order separately 2. Just for -480 version, the inverter applies current limit derating below 220V down to 2A/1A at 90V 4. Independent MPPT just with negative ground
PARAMETER
Input Side Absolute Maximum DC Input Voltage (Vmax,abs) Start-up DC Input Voltage (Vstart) Operating DC Input Voltage Range (Vdcmin...Vdcmax) Rated DC Input Power (Pdcr) Number of Independent MPPT (4) Maximum DC Input Power for each MPPT (PMPPTmax) DC Input Voltage Range with Parallel Configuration of MPPT at Pacr DC Power Limitation with Parallel Configuration of MPPT DC Power Limitation for each MPPT with Independent Configuration of MPPT at Pacr , max unbalance example Maximum DC Input Current (Idcmax) / for each MPPT (IMPPTmax) Maximum Input Short Circuit Current for each MPPT Number of DC Inputs Pairs for each MPPT DC Connection Type Input Protection Reverse Polarity protection Input Over Voltage Protection for each MPPT - Varistor Photovoltaic Array Isolation Control DC Switch Rating for each MPPT (-S Version) Fuse Rating (-FS Version) Output Side AC Grid Connection Type Rated AC Power (Pacr) Maximum AC Output Power (Pacmax) Rated AC Grid Voltage (Vac,r) AC Voltage Range Maximum AC Output Current (Iac,max) Rated Output Frequency (fr) Output Frequency Range (fmin...fmax) Nominal Power Factor (Cosphiac,r) Total Current Harmonic Distortion AC Connection Type Output Protection Anti-Islanding Protection Maximum AC Overcurrent Protection Output Overvoltage Protection - Varistor Operating Performance Maximum Efficiency (max) Weighted Efficiency (EURO/CEC) Feed In Power Threshold Stand-by Consumption Communication Wired Local Monitoring Remote Monitoring Wireless Local Monitoring User Interface Environmental Ambient Temperature Range Relative Humidity Noise Emission Maximum Operating Altitude without Derating Physical Environmental Protection Rating Cooling Dimension (H x W x D) Weight Mounting System Safety Isolation Level Marking Safety and EMC Standard Grid Standard Available Products Variants Standard - Positive Ground Standard - Negative Ground With AC and DC Switches - Positive Ground With AC and DC Switches - Negative Ground
1. Order separately 2. Just for -480 version, the inverter applies current limit derating below 220V down to 2A/1A at 90V 4. Independent MPPT just with negative ground
PVI-12.0-I-OUTD-US-480
PVI-12.0-I-OUTD-CAN-600
520 V 200 V (adj. 120...350 V) 0.7 x Vstart...520 V 12300 W 2 6800 W 250...470 V Linear Derating From MAX to Null [470VVMPPT520V] 6800 W [275VVMPPT470V] the other channel: Pdcr-6800W [220VVMPPT470V] 50.0 A / 25.0 A (2) 29.0 A 2 (3 on -S2 Version) Screw Terminal Block, 3 Knock-Outs: or 1 /w/ring red.) Yes, from limited current source 2 GFDI (for use with either Positive or Negative Grounded Arrays) 32 A / 600 V 12 A or 15 A / 600 V (1) Trifase (/Y) 12000 W 12500 W
480 V 422...528 V
16.0 A 60 Hz 59.3...60.5 Hz > 0.995 < 2% Screw Terminal Block, 3 Knock-Outs: According to UL 1741/IEE1547 20.0 A 3 plus gas arrester 97.3% - / 97.0% 30 W <8W
600 V 528...660 V
PVI-USB-RS485_232 (opt.), PVI-DESKTOP (opt.) PVI-AEC-EVO (opt.), AURORA-UNIVERSAL (opt.) PVI-DESKTOP (opt.) with PVI-RADIOMODULE (opt.) 16 characters x 2 lines LCD display -25...+60C /-13...140F with derating above 45C/113F 0...100% condensing < 50 db(A) @ 1 m 2000 m / 6560 ft NEMA 4X Natural 716mm x 645mm x 222mm / 28.2 x 25.4 x 8.7 958mm x 645mm x 222mm / 37.7 x 25.4 x 8.7 (-S/-S2 version) < 45.8 kg / 99.0 lb < 48.5 kg / 107 lb (-S Version) < 51.7 / 114 lb (-S2 Version) Wall bracket HF transformer cCSAus UL 1741, CSA - C22.2 N. 107.1-01 IEEE 1547 PVI-12.0-I-OUTD-US-480-PG PVI-12.0-I-OUTD-US-480-NG PVI-12.0-I-OUTD-S2-US-480-PG PVI-12.0-I-OUTD-S2-US-480-NG PVI-12.0-I-OUTD-CAN-600-PG PVI-12.0-I-OUTD-CAN-600-NG PVI-12.0-I-OUTD-S2-CAN-600-PG PVI-12.0-I-OUTD-S2-CAN-600-NG
AURORA TRIO
59
PVI-10.0-TL PVI-12.5-TL
GENERAL SPECIFICATIONS OUTDOOR MODELS
PVI-10.0-TL-OUTD PVI-10.0-TL-OUTD-S PVI-10.0-TL-OUTD-FS PVI-12.5-TL-OUTD PVI-12.5-TL-OUTD-S PVI-12.5-TL-OUTD-FS
60
AURORA TRIO
The three-phase 10.0 and 12.5 kW non-isolated inverter is an industry leader. Designed for commercial usage, this three-phase inverter is highly unique in its ability to control the performance of the PV panels, especially during periods of variable weather conditions. This transformerless device has two independent MPPTs and efficiency ratings of up to 97.7%. The wide input voltage range makes the inverter suitable to low power installations with reduced string size. It is available with an optional fully-integrated DC switch, fuse and remote controlled DC disconnect function. The unit is free of electrolytic capacitors, leading to a longer product lifetime.
Features
Electrolyte-free power converter to further increase the life expectancy and long term reliability True three-phase bridge topology for DC/AC output converter Each inverter is set on specific grid codes which can be selected in the field Dual input sections with independent MPP tracking, allows optimal energy harvesting from two
sub-arrays oriented in different directions Wide input range High speed and precise MPPT algorithm for real time power tracking and improved energy harvesting Flat efficiency curves ensure high efficiency at all output levels ensuring consistent and stable performance across the entire input voltage and output power range Outdoor enclosure for unrestricted use under any environmental conditions Integrated DC disconnect switch in compliance with international Standards (-S Version) RS-485 communication interface (for connection to laptop or datalogger) Compatible with PVI-RADIOMODULE for wireless communication with Aurora PVI-DESKTOP
AURORA TRIO
61
UNO TRIO
N PE
IN2
IN2
STANDARD VERSION
-S VERSION
REMOTE CONTROL +R -R
CONTROL CIRCUIT
-FS VERSION
PVI-10.0-TL-OUTD
99% 98% 97% 96% Efficiency [%] 95% 94% 93% 92% 91% 90% 0% 300 Vdc 570 Vdc 750 Vdc
PVI-12.5-TL-OUTD
100,00% 95,00% 90,00% 85,00% 80,00% 75,00% 70,00% % Pout nom 97.5 97.8 65,00% 60,00% 55,00% 50,00% 97.0 45,00% 40,00% 96.5 96.0 95.0 35,00% 30,00% 25,00% 20,00% 15,00% 10,00% 97,50-98,00 97,00-97,50 96,50-97,00 96,00-96,50 95,50-96,00 95,00-95,50 94,50-95,00 94,00-94,50 93,50-94,00 93,00-93,50 92,50-93,00
6%
13%
19%
25%
31%
38%
44%
50%
56%
63%
69%
75%
81%
88%
94% 100%
93.0 5,00% 300 330 360 390 420 450 480 510 540 570 600 630 660 690 720 750 Vin [Vdc]
62
AURORA TRIO
PARAMETER
Input Side Absolute Maximum DC Input Voltage (Vmax,abs) Start-up DC Input Voltage (Vstart) Operating DC Input Voltage Range (Vdcmin...Vdcmax) Rated DC Input Power (Pdcr) Number of Independent MPPT Maximum DC Input Power for each MPPT (PMPPTmax) DC Input Voltage Range with Parallel Configuration of MPPT at Pacr DC Power Limitation with Parallel Configuration of MPPT DC Power Limitation for each MPPT with Independent Configuration of MPPT at Pacr , max unbalance example Maximum DC Input Current (Idcmax) / for each MPPT (IMPPTmax) Maximum Input Short Circuit Current for each MPPT Number of DC Inputs Pairs for each MPPT DC Connection Type Input Protection Reverse Polarity protection Input Over Voltage Protection for each MPPT - Varistor Photovoltaic Array Isolation Control DC Switch Rating for each MPPT (-S Version) Fuse Rating (-FS Version) Output Side AC Grid Connection Type Rated AC Power (Pacr) Maximum AC Output Power (Pacmax) Rated AC Grid Voltage (Vac,r) AC Voltage Range Maximum AC Output Current (Iac,max) Rated Output Frequency (fr) Output Frequency Range (fmin...fmax) Nominal Power Factor (Cosphiac,r) Total Current Harmonic Distortion AC Connection Type Output Protection Anti-Islanding Protection Maximum AC Overcurrent Protection Output Overvoltage Protection - Varistor Operating Performance Maximum Efficiency (max) Weighted Efficiency (EURO/CEC) Feed In Power Threshold Stand-by Consumption Communication Wired Local Monitoring Remote Monitoring Wireless Local Monitoring User Interface Environmental Ambient Temperature Range Relative Humidity Noise Emission Maximum Operating Altitude without Derating Physical Environmental Protection Rating Cooling Dimension (H x W x D) Weight Mounting System Safety Isolation Level Marking Safety and EMC Standard Grid Standard Available Products Variants Standard With DC Switch With DC Switch and Fuse
1. The AC voltage range may vary depending on specific country grid standard 2. The Frequency range may vary depending on specific country grid standard 3. Limited to 10000 W for Benelux
PVI-10.0-TL-OUTD
PVI-12.5-TL-OUTD
10300 W
12800 W
6800 W 8000 W 300...750 V 360...750 W Linear Derating From MAX to Null [750VVMPPT850V] 8000 W [445VVMPPT750V] 6800 W [380VVMPPT750V] the other channel: Pdcr-6800W the other channel: Pdcr-8000W [195VVMPPT750V] [270VVMPPT750V] 36.0 A / 18.0 A 22.0 A 2 (-S Version) 3 (Standard or FS Version) Tool Free PV Connector WM / MC4 Yes, from limited current source 2 According to local standard 25 A / 1000 V 10 A / 1000 V Three phase (/Y) 10000 W 11000 W (3) 400 V 320...480 V 16.6 A 50 Hz 47...53 Hz (2) > 0.995 (adj. 0.9) < 2% Screw terminal block According to local standard 19.0 A 3 plus gas arrester 97.8% 97.1% / 30.0 W < 10.0 W PVI-USB-RS485_232 (opt.), PVI-DESKTOP (opt.) PVI-AEC-EVO (opt.), AURORA-UNIVERSAL (opt.) PVI-DESKTOP (opt.) with PVI-RADIOMODULE (opt.) 16 characters x 2 lines LCD display -25...+60C (-13...+140F) -25...+60C /-13...140F with derating above 55C (131F) with derating above 50C/122F 0...100% condensing < 50 db(A) @ 1 m 2000 m / 6560 ft IP 65 Natural 716mm x 645mm x 222mm / 28.2 x 25.4 x 8.7 < 41.0 kg / 90.4 lb Wall bracket Transformerless CE EN 50178, AS/NZS3100, AS/NZS 60950, EN61000-6-2, EN61000-6-4, EN61000-3-11, EN61000-3-12 DK 5940, VDE 0126-1-1, G59, EN 50438, RD1663, AS 4777, BDEW PVI-10.0-TL-OUTD PVI-10.0-TL-OUTD-S PVI-10.0-TL-OUTD-FS PVI-12.5-TL-OUTD PVI-12.5-TL-OUTD-S PVI-12.5-TL-OUTD-FS 97.2% / 22.0 A 20.0 A 12500 W 13800 W
AURORA TRIO
63
TRIO-27.6-TL TRIO-20.0-TL
GENERAL SPECIFICATIONS OUTDOOR MODELS
TRIO-27.6-TL-OUTD TRIO-20.0-TL-OUTD
NEW
64
AURORA TRIO
The latest in Power-Ones Aurora Trio range, this new-look three-phase inverter fills a specific niche in the commercial solar market. This new three-phase inverter benefits from the three-phase inverter technology perfected in the PVI-10.0 and 12.5, probably the worlds most commonly used three-phase inverter which has led the way in best-in-class efficiency. Controlling more PV panels than its smaller predecessor, the Trio-27.6 and Trio-20.0 will offer more flexibility and control to installers who have large installations with varying aspects or orientations. This device has two independent MPPTs and efficiency ratings of up to 98.2%. The very wide input voltage range makes the inverter suitable to installations with reduced string size. The new look inverter has new features including a special built-in heat sink compartment and front panel display system. The unit is free of electrolytic capacitors, leading to a longer product lifetime.
Features
Electrolyte-free power converter to further increase the life expectancy and long term reliability Quiet Rail True three-phase bridge topology for DC/AC output converter Each inverter is set on specific grid codes which can be selected in the field Dual input sections with independent MPP tracking, allows optimal energy harvesting from two sub-arrays oriented in different directions Wide input range Detachable wiring box to allow an easy installation Integrated string combiner with different options of configuration which include DC and AC disconnect switch in compliance with international Standards (-S2 and -S2X version) High speed and precise MPPT algorithm for real time power tracking and improved energy harvesting Flat efficiency curves ensure high efficiency at all output levels ensuring consistent and stable performance across the entire input voltage and output power range Outdoor enclosure for unrestricted use under any environmental conditions
AURORA TRIO
65
UNO TRIO
IN1A(+) IN1(+) + IN1B(+) IN1C(+) IN1D(+) *IN1E(+) IN1 IN1A(-) IN1B(-) IN1(-) IN1C(-) IN1D(-) *IN1E(-) CURRENT READING
MPPT 1 (DC/DC)
BULK CAPS
INVERTER (DC/AC)
IN1
IN1
LINE FILTER
-S2 VERSION
L1, S L2, S L3, S N, S PE L1 L2 L3 N
-S2X VERSION
L1, S L2, S L3, S N, S PE
IN2A(+) IN2(+) + IN2B(+) IN2C(+) IN2D(+) *IN2E(+) IN2 IN2A(-) IN2B(-) IN2(-) IN2C(-) IN2D(-) *IN2E(-)
CURRENT READING
OVP MONITORING
MPPT 2 (DC/DC)
PE
IN2
IN2
-S2 VERSION
OVP MONITORING
-S2X VERSION
* not present on TRIO-20.0-TL CURRENT READING OVP MONITORING + IN1(+)
P
CONTROL CIRCUIT
IN1
IN1(-)
PT 100 PT 1000 4...20mA / 0...10V adj 4...20mA / 0...10V adj ON/OFF EXT
*
PC_RS485
GND
+ T/R
+ IN2(+)
- T/R GND
+R GND
SD CARD
IN2
PMU AN 1 ALARM
IN2(-)
N.C N.O C
STANDARD VERSION
TRIO-20.0-TL-OUTD
100 99 98 97 96 Efficiency, % 95 94 93
500 Vdc
TRIO-27.6-TL-OUTD
100 99 98 97 96 Efficiency, % 95 94 93
500 Vdc
92 91 90
90%
100%
0%
10%
20%
30%
40%
50%
60%
70%
80%
90%
100%
66
AURORA TRIO
PARAMETER
Input Side Absolute Maximum DC Input Voltage (Vmax,abs) Start-up DC Input Voltage (Vstart) Operating DC Input Voltage Range (Vdcmin...Vdcmax) Rated DC Input Power (Pdcr) Number of Independent MPPT Maximum DC Input Power for each MPPT (PMPPTmax) DC Input Voltage Range with Parallel Configuration of MPPT at Pacr DC Power Limitation with Parallel Configuration of MPPT DC Power Limitation for each MPPT with Independent Configuration of MPPT at Pacr , max unbalance example Maximum DC Input Current (Idcmax) / for each MPPT (IMPPTmax) Maximum Input Short Circuit Current for each MPPT Number of DC Inputs Pairs for each MPPT DC Connection Type Input Protection Reverse Polarity protection Input Over Voltage Protection for each MPPT - Varistor Input Over Voltage Protection for each MPPT Plug In Modular Surge Arrester (-S2X Version) Photovoltaic Array Isolation Control DC Switch Rating for each MPPT (-S Version) Fuse Rating (-FS Version) Output Side AC Grid Connection Type Rated AC Power (Pacr) Maximum AC Output Power (Pacmax) Rated AC Grid Voltage (Vac,r) AC Voltage Range Maximum AC Output Current (Iac,max) Rated Output Frequency (fr) Output Frequency Range (fmin...fmax) Nominal Power Factor (Cosphiac,r) Total Current Harmonic Distortion AC Connection Type Output Protection Anti-Islanding Protection Maximum AC Overcurrent Protection Output Overvoltage Protection - Varistor Output Over Voltage Protection Plug In Modular Surge Arrester (-S2X Version) Operating Performance Maximum Efficiency (max) Weighted Efficiency (EURO/CEC) Feed In Power Threshold Stand-by Consumption Communication Wired Local Monitoring Remote Monitoring Wireless Local Monitoring User Interface Environmental Ambient Temperature Range Relative Humidity Noise Emission Maximum Operating Altitude without Derating Physical Environmental Protection Rating Cooling Dimension (H x W x D) Weight Mounting System Safety Isolation Level Marking Safety and EMC Standard Grid Standard Available Products Variants Standard With DC Switch With DC Switch and Fuse
1. The AC voltage range may vary depending on specific country grid standard 2. The Frequency range may vary depending on specific country grid standard
TRIO-20.0-TL-OUTD
TRIO-27.6-TL-OUTD
20750 W
28600 W
16000 W [500VVMPPT800V] 12000 W [480VVMPPT800V] the other channel: Pdcr-12000W the other channel: Pdcr-16000W [350VVMPPT800V] [400VVMPPT800V] 50.0 A / 25.0 A 64.0 A / 32.0 A 30.0 A 40.0 A 1 (4 on -S2X version) 1 (5 on -S2X version) Tool Free PV Connector WM / MC4 Yes, from limited current source 2 3 (Classe II) According to local standard 40 A / 1000 V 10 A / 1000 V 20000 W 22000 W 33.0 A Three phase (/Y) 400 V 320...480 V (1) 50 Hz 47...53 Hz (2) > 0.995 (adj. 0.9) < 3% Cage clamp According to local standard 4 4 (Class II) 98.2% 98.0% / 98.0% 40 W < 8W PVI-USB-RS485_232 (opt.), PVI-DESKTOP (opt.) PVI-AEC-EVO (opt.), AURORA-UNIVERSAL (opt.) PVI-DESKTOP (opt.) with PVI-RADIOMODULE (opt.) Graphic display -25...+60C /-13...140F with derating above 45C/113F 0...100% condensing < 50 db(A) @ 1 m 2000 m / 6560 ft IP 65 Natural 1060mm x 751mm x 291mm / 41.7 x 29.6 x 11.4 < 70.0 kg / 154.3 lb < 75.0 kg / 165.4 lb Wall bracket Transformerless CE EN 50178, AS/NZS3100, AS/NZS 60950, EN61000-6-1, EN61000-6-3, EN61000-3-11, EN61000-3-12 Enel Guideline, VDE 0126-1-1, G59/2, EN 50438, RD1663, AS 4777 TRIO-20.0-TL-OUTD-400 TRIO-20.0-TL-OUTD-S2-400 TRIO-20.0-TL-OUTD-S2X-400 TRIO-27.6-TL-OUTD-400 TRIO-27.6-TL-OUTD-S2-400 TRIO-27.6-TL-OUTDS2X-400 27600 W 30000 W 45.0 A
34.0 A
46.0 A
AURORA TRIO
67
68
AURORA LITE
LITE
AURORA LITE
69
PVI-250 PVI-500
GENERAL SPECIFICATIONS CENTRALIZED MODELS
PVI-250.0-TL-CN PVI-500.0-TL-CN
NEW
PVI-250-TL-CN
70
AURORA LITE
This product offers high performance with affordable capital expenditure and has been specifically designed for the fast growing Asian market. Power-Ones new 250kW and 500kW utility grade central inverters have a number of key features, including a very high efficiency of 98.5%, electrolytic capacitor-free leading to longer MTBF (mean time between failures), compact size and weight; touch screen display, and 1000 Voc (open circuit voltage) rating. This product design is the result of the experience we have acquired with more than 50MW of installation in the challenging Asian market.
Features
Reverse-polarity protection minimizes potential damage caused by array mis-wiring Maximum input voltage up to 1000 Vdc, high design flexibility and reduced
distribution losses for large scale PV plants DC
Transformer-less inverter for direct connection to MV transformer Integrated DC and AC distribution and protection. Fully equipped for connection, additional
accessories not required High efficiencies deliver more energy Two independent RS-485 communication interfaces for inverter and intelligent string combiner monitoring
AURORA LITE
71
PV ARRAY 1(+) PV ARRAY 2(+) PV ARRAY 3(+) PV ARRAY 4(+) PV ARRAY 5(+) A AC FILTER PV ARRAY 1(-) PV ARRAY 2(-) PV ARRAY 3(-) PV ARRAY 4(-) PV ARRAY 5(-) GROUND FAULT DETECTION / REVERSE POLARITY DETECTION EMI FILTER
OVR
INVERTER 1
GRID CONTROL
PV ARRAY 6(+) PV ARRAY 7(+) PV ARRAY 8(+) PV ARRAY 9(+) PV ARRAY 10(+) A AC FILTER PV ARRAY 6(-) PV ARRAY 7(-) PV ARRAY 8(-) PV ARRAY 9(-) PV ARRAY 10(-) GROUND FAULT DETECTION / REVERSE POLARITY DETECTION EMI FILTER L1 L2 L3 P
OVR
INVERTER 1
GRID CONTROL
24 VDC
PVI STRINGCOMB
PVI DISPLAY
PVI AEC-EVO
PVI-250.0-TL-CN
99,0
98,0
97,0
96,0
Efficiency, %
95,0
94,0
93,0
92,0
810 Vdc
91,0 0,0%
10,0%
20,0%
30,0%
40,0%
50,0%
60,0%
70,0%
80,0%
90,0%
100,0%
110,0%
72
AURORA LITE
PARAMETER
Input Side Absolute Maximum DC Input Voltage (Vmax,abs) MPPT Input DC Voltage Range (VMPPTmin,r ... VMPPTmax,r) MPPT Input DC Range (VMPPTmin,f ... VMPPTmax,f) at Full Power Number of Independent MPPT Multi-Master Number of Independent MPPT Master/Slave Maximum Combined DC Input Current (Idcmaxc) Maximum DC Input Current for Each Module (Idcmax,m) Number of DC Inputs Pairs DC Connection Type Input Protection Reverse Polarity Protection Input Over Voltage Protection - Varistor Photovoltaic Array Isolation Control Fuse Size for Each Input Pair Output Side AC Grid Connection Type Rated AC Power (Pac,r) Rated Grid Voltage (Vac,r) AC Voltage Range (Vacmin...Vacmax) Maximum Output Current (Iac,max) Rated Frequency (fr) Frequency Range (fmin...fmax) Power Factor (Cosphiac,r) Total Harmonic Distortion AC Connection Type Output Protection Anti-Islanding Protection Output Overvoltage Protection (Varistor) Night Time Disconnect AC Circuit Breaker Operating Performance Maximum Efficiency (max) Weithted Efficiency (EURO / CEC) Stand-by Consumption/Night-time power loss AC Auxiliary Supply Auxiliary Supply Consumption Auxiliary Supply Consumption without Cooling Inverter Switching Frequency Communication Wired Local Monitoring Remote Monitoring AURORA String Combiner User Interface Environmental Ambient Temperature Range Relative Humidity Noise Emission Maximum Operating Altitude without Derating Physical Environmental Protection Rating Cooling Required Air Cooling Flow Dimension (H x W x D) Weight Safety Transformer Marking Safety and EMC Standard Grid Standard
1. The AC voltage range may vary depending on specific country grid standard 2. The Frequency range may vary depending on specific country grid standard 3. Power factor variations beyond 0.9 imply a reduction of the active power
PVI-250.0-TL-CN
1000 V 475....900 V 475....900 V 1 Not applicable 550 A 550 A 5 10 x 70 mm2 (M10) Yes, from limited current source 2 for each input, Class II According to local standard 125 A / 1100 V Three phases ( / ) 250 kW 320 V 272...368 V (1) 450 A 50/60 Hz 47...53 / 57...63 Hz (2) > 0.995 (adj. 0.90) (3) < 3% (@ Pac,r) 3 x 240 mm2 (M10) According to local standard 3, star connected, Class II Yes 690 V / 630 A (T5) 98.5% 98.2% / < 33 W 3 x 400 Vac +N, 50/60 Hz < 405 W < 100 W 9 kHz PVI-USB-RS485_232 (opt.) PVI-AEC-EVO (opt.), AURORA-UNIVERSAL (opt.) PVI-STRINGCOMB (opt.) TFT LCD 5.7 -20...+ 50C/-4...122F with derating above 45C/113F 0...95% non condensing <62 dB(A) @ 1 m 1000 m / 3280 ft
PVI-500.0-TL-CN
1000 V 475....900 V 475....900 V 2 1 1100 A 550 A 10 20 x 70 mm2 (M10) Yes, from limited current source 2 for each input, Class II According to local standard 125 A / 1100 V Three phases () 500 kW 320 V 272...368 V (1) 900 A 50/60 Hz 47...53 / 57...63 Hz (2) > 0.995 (adj. 0.90) (3) < 3% (@ Pac,r) 3 x 240 mm2 (M10) According to local standard 3, star connected, Class II Yes 690 V / 1kA (T6) 98.5% 98.2% / < 66 W 3 x 400 Vac +N, 50/60 Hz < 810 W < 220 W 9 kHz PVI-USB-RS485_232 (opt.) PVI-AEC-EVO (opt.), AURORA-UNIVERSAL (opt.) PVI-STRINGCOMB (opt.) TFT LCD 5.7 -20...+ 50C/-4...122F with derating above 45C/113F 0...95% non condensing <62 dB(A) @ 1 m 1000 m / 3280 ft
IP 20 IP 20 Air Forced Air Forced 4000 m3/h - 2360 CFM 8000 m3/h - 4720 CFM 2280mm x 1200mm x 800mm / 89.8 x 47.2 x31.5 2280mm x 2000mm x 800mm / 89.8 x 78.7 x 31.5 < 800 kg / 1765 lb < 1200 kg / 2645 lb No No CE, CQC CE, CQC EN 50178, EN 61000-3-12, EN61000-6-2, EN61000- EN 50178, EN 61000-3-12, EN61000-6-2, EN610006-4, IEC 62109-1 6-4, IEC 62109-1 CNCA/CTS0004, GB/T 19939, IEC 62116 CNCA/CTS0004, GB/T 19939, IEC 62116
AURORA LITE
73
74
AURORA PLUS
PLUS
AURORA PLUS
75
These extremely scalable modular inverter systems, based on 55kW modular blocks, increase usable power and improve availability. The reduction of performance in any individual module will not impact the energy-harvesting capabilities of other modules. The product is available with and without transformer. Industry-leading power conversion efficiencies of up to 98% (-TL), combined with high-speed Maximum Power Point Tracking (MPPT) channels, optimize energy harvesting across a wide array of operating conditions. Inverter systems are delivered pre-configured and pre-tested, significantly reducing on-site wiring and testing. In case of ungrounded application the unit can be configured as single or multiple MPPT (with exception of PVI-55.0/-TL).
Features
Reduced susceptibility to a single fault. In case of a component failure, a maximum of 55kW will be lost Reduced acoustic noise due to the high switching frequency Reverse-polarity protection minimizes potential damage caused by array mis-wiring Maximum input voltage up to 1000Vdc, high design flexibility and reduced DC distribution losses for large scale PV plants Integrated DC and AC distribution and protection. Fully equipped for connection, additional accessories not required Easy installation and maintenance procedure. Front extractible DC/AC converters and accessibility to all critical parts High efficiencies deliver more energy Two independent RS-485 communication interfaces for inverter and intelligent string combiner monitoring Integrated DC disconnect switch for each 55 kW module AC and DC side integrated protection (fuses and OVR) easily replaceable Compliant to BDEW
76 AURORA PLUS
OVR REVERSE POLARITY PROTECTION PV ARRAY 1 (+) PV ARRAY 1 (-) DC FUSE DC BREAKER EMC FILTER INVERTER MODULE 55.0kW
CONTACT
DC / AC INVERTER
LINE FILTER
CONTROL CIRCUIT
OVR REVERSE POLARITY PROTECTION PV ARRAY 2 (+) PV ARRAY 2 (-) DC FUSE DC BREAKER EMC FILTER INVERTER MODULE 55.0kW
CONTACT
DC / AC INVERTER
LINE FILTER
CONTROL CIRCUIT
OVR REVERSE POLARITY PROTECTION PV ARRAY 1 (+) PV ARRAY 1 (-) DC FUSE DC BREAKER EMC FILTER INVERTER MODULE 55.0kW
CONTACT
CONTROL CIRCUIT
OVR REVERSE POLARITY PROTECTION PV ARRAY 2 (+) PV ARRAY 2 (-) DC FUSE DC BREAKER EMC FILTER INVERTER MODULE 55.0kW
CONTACT
AC FUSE
DC / AC INVERTER
LINE FILTER
CONTROL CIRCUIT
OVR REVERSE POLARITY PROTECTION PV ARRAY 1 (+) PV ARRAY 1 (-) DC FUSE DC BREAKER EMC FILTER INVERTER MODULE 55.0kW
CONTACT
DC / AC INVERTER
LINE FILTER
CONTROL CIRCUIT
OVR REVERSE POLARITY PROTECTION PV ARRAY 2 (+) PV ARRAY 2 (-) DC FUSE DC BREAKER EMC FILTER INVERTER MODULE 55.0kW
CONTACT
DC / AC INVERTER
LINE FILTER
24 VDC
CONTROL CIRCUIT
208 VAC CONTROL CIRCUIT
PVI-55.0/330.0-TL
100,00 99,00 98,00 97,00 96,00 95,00 94,00 550Vdc 93,00 92,00 91,00 90,00 0% 485Vdc 500Vdc
Efficiency [%]
10%
20%
30%
40%
50%
60%
70%
80%
90%
100%
AURORA PLUS
DC / AC INVERTER
LINE FILTER
300kVA TRANSFORMER
/
77
Efciency Curves
PVI-55.0
98,00 98,00
PVI-110.0
97,00
97,00
96,00
96,00
95,00
485Vdc
94,00
500Vdc
94,00
500Vdc
93,00
550Vdc
93,00
550Vdc
92,00
92,00
91,00
91,00
90,00 0% 10% 20% 30% 40% 50% 60% 70% 80% 90% 100% Pac / Pnom [%]
90,00 0%
10%
20%
30%
40%
50%
60%
70%
80%
90%
100%
78
AURORA PLUS
PARAMETER
Input Side Absolute Maximum DC Input Voltage (Vmax,abs) MPPT Input DC Voltage Range (VMPPTmin,r ... VMPPTmax,r) MPPT Input DC Range (VMPPTmin,f ... VMPPTmax,f) at Full Power Number of Independent MPPT Multi-Master Number of Independent MPPT Multi - Master/Slave Number of Independent MPPT Master/Slave Maximum Combined DC Input Current (Idcmaxc) Maximum DC Input Current for Each Module (Idcmax,m) Number of DC Inputs Pairs DC Connection Type Input Protection Reverse Polarity Protection Input Over Voltage Protection - Varistor Photovoltaic Array Isolation Control Fuse Size for Each Input Pair Output Side AC Grid Connection Type Rated AC Power (Pac,r) Rated Grid Voltage (Vac,r) AC Voltage Range (Vacmin...Vacmax) Maximum Output Current (Iac,max) Rated Frequency (fr) Frequency Range (fmin...fmax) Power Factor (Cosphiac,r) Total Harmonic Distortion AC Connection Type Output Protection Anti-Islanding Protection Output Overvoltage Protection (Varistor) Night Time Disconnect AC Circuit Breaker Operating Performance Maximum Efficiency (max) Weithted Efficiency (EURO / CEC) Stand-by Consumption/Night-time power loss AC Auxiliary Supply Auxiliary Supply Consumption Auxiliary Supply Consumption without Cooling Inverter Switching Frequency Communication Wired Local Monitoring Remote Monitoring AURORA String Combiner User Interface Environmental Ambient Temperature Range Relative Humidity Noise Emission Maximum Operating Altitude without Derating Physical Environmental Protection Rating Cooling Required Air Cooling Flow Dimension (H x W x D) Weight Weight of the module Safety Transformer Marking Safety and EMC Standard Grid Standard
1. The AC voltage range may vary depending on specific country grid standard 2. The Frequency range may vary depending on specific country grid standard 3. Power factor variations beyond 0.9 imply a reduction of the active power
PVI-55.0
PVI-55.0-TL
PVI-110.0
PVI-110.0-TL
1000 V 485...950 V 485...850 V 1 Not applicable 1 124 A 124 A 1 1x185mm2 (M10) YES, with series diode 2 for each input pair, Class II According to local standard 125 A / 1000 V Three phases ( / ) 55 kW 400 V 320...480 V (1) 81 A 320 V 256...368 V (1) 100 A Three phases ()
1000 V 485...950 V 485...850 V 2 Not applicable 1 248 A 124 A 2 1x185mm2 (M10) + 1x300mm2 (M12) YES, with series diode 2 for each input pair, Class II According to local standard 125 A / 1000 V Three phases ( / ) 110 kW 400V 320...480 V (1) 160 A 320 V 256...368 V (1) 200 A Three phases ()
50/60 Hz 47...53 / 57...63 Hz (2) > 0.995 (adj. 0.90) (3) < 3% (@ Pac,r) 1 x 95 mm2 (M8) 1 x 300 mm2 (M12) According to local standard Yes, Class II Yes 50 kA 96.30% 98.00% 95.1% / 96.0% 97.7% / 98.0% < 17 W < 23 W 3x400 Vac +N, 50/60 Hz < 0.36% of Pac,r < 0.24% of Pac,r < 0.25% of Pac,r < 0.22% of Pac,r 18 kHz PVI-USB-RS485_232 (opt.) PVI-AEC-EVO (opt.), AURORA-UNIVERSAL (opt.) PVI-STRINGCOMB (opt.) 16 characters x 2 line LCD display for each module -10...+ 60C/+14...140F with derating above 50C/122F 0...95% non condensing <62 dB(A) @ 1 m 1000 m / 3280 ft
50/60 Hz 47...53 / 57...63 Hz (2) > 0.995 (adj. 0.90) (3) < 3% (@ Pac,r) 1 x 95 mm2 (M8) 1 x 300 mm2 (M12) According to local standard Yes, Class II Yes 50 kA 96.40% 98.00% 95.2% / 96.0% 97.7% / 98.0% < 24 W < 19 W 3 x 400 Vac +N, 50/60 Hz < 0.31% of Pac,r < 0.24% of Pac,r < 0.23% of Pac,r < 0.22% of Pac,r 18 kHz PVI-USB-RS485_232 (opt.) PVI-AEC-EVO (opt.), AURORA-UNIVERSAL (opt.) PVI-STRINGCOMB (opt.) 16 characters x 2 line LCD display for each module -10...+ 60C/+14...140F with derating above 50C/122F 0...95% non condensing < 63 db (A) @ 1 m 1000 m / 3280 ft
IP 20 IP 20 Air Forced Air Forced 1600 m3/h - 944 CFM 2800 m3/h - 1652 CFM 2400 m3/h - 1416 CFM 1675mm x 1250mm x 850mm 1077mm x 1250mm x 850mm 1675mm x 1250mm x 850mm 1077mm x 1250mm x 850mm / 69.5 x 49,2 x 33.5 / 42.4 x 49.2 x 33.5 / 65.9 x 49.2 x 33.5 / 42,4 x 49.2 x 33.5 < 700 kg / 1543 lb < 350 kg / 771 lb < 800 kg / 1765 lb < 480 kg / 1058 lb < 60 kg / 132 lb < 60 kg / 132 lb No Yes No CE CE EN 50178, EN61000-6-2, EN61000-6-4, EN61000-3-11, EN 50178, EN61000-6-2, EN61000-6-4, EN61000-3-11, EN61000-3-12 EN61000-3-12 Enel Guideline, BDEW, RD 1663 Enel Guideline, BDEW, RD 1663 Yes
AURORA PLUS
79
Efciency Curves
PVI-55.0/330.0-TL
100,00 99,00 98,00
PVI-165.0/220.0
98,00
97,00
96,00
97,00 96,00 Efficiency [%] 95,00 94,00 550Vdc 93,00 485Vdc
Efficiency [%]
95,00
485Vdc
500Vdc
94,00
500Vdc
93,00
550Vdc
92,00
92,00 91,00 90,00 0% 10% 20% 30% 40% 50% 60% 70% 80% 90% 100% Pac / Pnom [%]
91,00
90,00 0%
10%
20%
30%
40%
50%
60%
70%
80%
90%
100%
80
AURORA PLUS
PARAMETER
Input Side Absolute Maximum DC Input Voltage (Vmax,abs) MPPT Input DC Voltage Range (VMPPTmin,r ... VMPPTmax,r) MPPT Input DC Range (VMPPTmin,f ... VMPPTmax,f) at Full Power Number of Independent MPPT Multi-Master Number of Independent MPPT Multi - Master/Slave Number of Independent MPPT Master/Slave Maximum Combined DC Input Current (Idcmaxc) Maximum DC Input Current for Each Module (Idcmax,m) Number of DC Inputs Pairs DC Connection Type Input Protection Reverse Polarity Protection Input Over Voltage Protection - Varistor Photovoltaic Array Isolation Control Fuse Size for Each Input Pair Output Side AC Grid Connection Type Rated AC Power (Pac,r) Rated Grid Voltage (Vac,r) AC Voltage Range (Vacmin...Vacmax) Maximum Output Current (Iac,max) Rated Frequency (fr) Frequency Range (fmin...fmax) Power Factor (Cosphiac,r) Total Harmonic Distortion AC Connection Type Output Protection Anti-Islanding Protection Output Overvoltage Protection (Varistor) Night Time Disconnect AC Circuit Breaker Operating Performance Maximum Efficiency (max) Weithted Efficiency (EURO / CEC) Stand-by Consumption/Night-time power loss AC Auxiliary Supply Auxiliary Supply Consumption Auxiliary Supply Consumption without Cooling Inverter Switching Frequency Communication Wired Local Monitoring Remote Monitoring AURORA String Combiner User Interface Environmental Ambient Temperature Range Relative Humidity Noise Emission Maximum Operating Altitude without Derating Physical Environmental Protection Rating Cooling Required Air Cooling Flow Dimension (H x W x D) Weight Weight of the module Safety Transformer Marking Safety and EMC Standard Grid Standard
1. The AC voltage range may vary depending on specific country grid standard 2. The Frequency range may vary depending on specific country grid standard 3. Power factor variations beyond 0.9 imply a reduction of the active power
PVI-165.0
PVI-165.0-TL
PVI-220.0
PVI-220.0-TL
1000 V 485...950 V 485...850 V 3 2 1 372 A 124 A 3 2x185mm2 (M10) + 1x300mm2 (M12) YES, with series diode 2 for each input pair, Class II According to local standard 125 A / 1000 V Three phases ( / ) Three phases () 165 kW 165 kW 400 V 320 V 320...480 V (1) 256...368 V (1) 240 A 300 A 50/60 Hz 47...53 / 57...63 Hz (2) > 0.995 (adj. 0.90) (3) < 3% (@ Pac,r) 1 x 185 mm2 (M10) 2 x 300 mm2 (M12) According to local standard Yes, Class II Yes 50 kA 96.50% 98.00% 95.3% / 96.0% 97.7% / 98.0% < 31 W < 26 W 3 x 400 Vac +N, 50/60 Hz < 0.30% of Pac,r < 0.24% of Pac,r < 0.23% of Pac,r < 0.22% of Pac,r 18 kHz PVI-USB-RS485_232 (opt.) PVI-AEC-EVO (opt.), AURORA-UNIVERSAL (opt.) PVI-STRINGCOMB (opt.) 16 characters x 2 line LCD display for each module -10...+ 60C/+14...140F with derating above 50C/122F 0...95% non condensing < 68 db (A) @ 1 m < 66 db (A) @ 1 m 1000 m / 3280 ft IP 20 Air Forced 4000 m3/h - 2360 CFM 3200 m3/h - 1888 CFM
1000 V 485...950 V 485...850 V 4 2 1 496 A 124 A 4 2x185mm2 (M10)+ 2x300mm2 (M12) YES, with series diode 2 for each input pair, Class II According to local standard 125 A / 1000 V Three phases ( / ) Three phases () 220 kW 220 kW 400 V 320 V 320...480 V (1) 256...368 V (1) 320 A 400 A 50/60 Hz 47...53 / 57...63 Hz (2) > 0.995 (adj. 0.90) (3) < 3% (@ Pac,r) 1 x 185 mm2 (M10) 2 x 300 mm2 (M12) According to local standard Yes, Class II Yes 50 kA 96.50% 98.00% 95.3% / 96.0% 97.7% / 98.0% < 28 W < 33 W 3 x 400 Vac +N, 50/60 Hz < 0.28% of Pac,r < 0.24% of Pac,r < 0.22% of Pac,r < 0.22% of Pac,r 18 kHz PVI-USB-RS485_232 (opt.) PVI-AEC-EVO (opt.), AURORA-UNIVERSAL (opt.) PVI-STRINGCOMB (opt.) 16 characters x 2 line LCD display for each module -10...+ 60C/+14...140F with derating above 50C/122F 0...95% non condensing < 72 db (A) @ 1 m < 69 db (A) @ 1 m 1000 m / 3280 ft IP 20 Air Forced 4800 m3/h - 2832 CFM 4000 m3/h - 2360 CFM
2184mm x 1250mm x 850mm 1675mm x 1250mm x 850mm 2184mm x 1250mm x 850mm 1675mm x 1250mm x 850mm / 86.0 x 49.2 x 33.5 / 65,9 x 49,2 x 33.5 / 86.0 x 49.2 x 33.5 / 65,9 x 42,9 x 33.5 < 1200 kg / 2646 lb < 680 kg / 1500 lb < 60 kg / 132 lb Yes < 1300 kg / 2867 lb < 780 kg / 1720 lb < 60 kg / 132 lb
No Yes No CE CE EN 50178, EN61000-6-2, EN61000-6-4, EN61000-3-11, EN 50178, EN61000-6-2, EN61000-6-4, EN61000-3-11, EN61000-3-12 EN61000-3-12 Enel Guideline, BDEW, RD 1663 Enel Guideline, BDEW, RD 1663
AURORA PLUS
81
Efciency Curves
PVI-55.0/330.0-TL
100,00 99,00 98,00
PVI-275.0/330.0
98,00
97,00
96,00
97,00 96,00 Efficiency [%] 95,00 94,00 550Vdc 93,00 485Vdc
95,00
Efficiency [%]
485Vdc
500Vdc
94,00
500Vdc
93,00
550Vdc
92,00
92,00 91,00 90,00 0% 10% 20% 30% 40% 50% 60% 70% 80% 90% 100% Pac / Pnom [%]
91,00
90,00 0%
10%
20%
30%
40%
50%
60%
70%
80%
90%
100%
82
AURORA PLUS
PARAMETER
Input Side Absolute Maximum DC Input Voltage (Vmax,abs) MPPT Input DC Voltage Range (VMPPTmin,r ... VMPPTmax,r) MPPT Input DC Range (VMPPTmin,f ... VMPPTmax,f) at Full Power Number of Independent MPPT Multi-Master Number of Independent MPPT Multi - Master/Slave Number of Independent MPPT Master/Slave Maximum Combined DC Input Current (Idcmaxc) Maximum DC Input Current for Each Module (Idcmax,m) Number of DC Inputs Pairs DC Connection Type Input Protection Reverse Polarity Protection Input Over Voltage Protection - Varistor Photovoltaic Array Isolation Control Fuse Size for Each Input Pair Output Side AC Grid Connection Type Rated AC Power (Pac,r) Rated Grid Voltage (Vac,r) AC Voltage Range (Vacmin...Vacmax) Maximum Output Current (Iac,max) Rated Frequency (fr) Frequency Range (fmin...fmax) Power Factor (Cosphiac,r) Total Harmonic Distortion AC Connection Type Output Protection Anti-Islanding Protection Output Overvoltage Protection (Varistor) Night Time Disconnect AC Circuit Breaker Operating Performance Maximum Efficiency (max) Weithted Efficiency (EURO / CEC) Stand-by Consumption/Night-time power loss AC Auxiliary Supply Auxiliary Supply Consumption Auxiliary Supply Consumption without Cooling Inverter Switching Frequency Communication Wired Local Monitoring Remote Monitoring AURORA String Combiner User Interface Environmental Ambient Temperature Range Relative Humidity Noise Emission Maximum Operating Altitude without Derating Physical Environmental Protection Rating Cooling Required Air Cooling Flow Dimension (H x W x D) Weight Weight of the module Safety Transformer Marking Safety and EMC Standard Grid Standard
1. The AC voltage range may vary depending on specific country grid standard 2. The Frequency range may vary depending on specific country grid standard 3. Power factor variations beyond 0.9 imply a reduction of the active power
PVI-275.0
PVI-275.0-TL
PVI-330.0
PVI-330.0-TL
1000 V 485...950 V 485...850 V 5 3 1 620 A 124 A 5 3x185mm2 (M10) +2x300mm2 (M12) YES, with series diode 2 for each input pair, Class II According to local standard 125 A / 1000 V Three phases ( / ) 275 kW 400 V 320...480 V (1) 400 A 320 V 256...368 V (1) 500 A Three phases ()
1000 V 485...950 V 485...850 V 6 3 1 744 A 124 A 6 3x185mm2 (M10) +3x300mm2 (M12) YES, with series diode 2 for each input pair, Class II According to local standard 125 A / 1000 V Three phases ( / ) 400 V 320...480 V (1) 480 A Three phases () 330 kW 320 V 256...368 V (1) 600 A
50/60 Hz 47...53 / 57...63 Hz (2) > 0.995 (adj. 0.90) (3) < 3% (@ Pac,r) 1 x 240 mm2 (M12) 2 x 300 mm2 (M12) According to local standard Yes, Class II Yes 50 kA 96.70% 98.00% 96.5% / 96.0% 97.7% / 98.0% < 45 W < 40 W 3 x 400 Vac +N, 50/60 Hz < 0.29% of Pac,r < 0.24% of Pac,r < 0.22% of Pac,r < 0.22% of Pac,r 18 kHz PVI-USB-RS485_232 (opt.) PVI-AEC-EVO (opt.), AURORA-UNIVERSAL (opt.) PVI-STRINGCOMB (opt.) 16 characters x 2 line LCD display for each module -10...+ 60C/+14...140F with derating above 50C/122F 0...95% non condensing < 75 db (A) @ 1 m < 72 db (A) @ 1 m 1000 m / 3280 ft
50/60 Hz 47...53 / 57...63 Hz (2) > 0.995 (adj. 0.90) (3) < 3% (@ Pac,r) 1 x 240 mm2 (M12) 2 x 300 mm2 (M12) According to local standard Yes, Class II Yes 50 kA 96.70% 98.00% 96.5% / 96.0% 97.7% / 98.0% < 52 W < 47 W 3 x 400 Vac +N, 50/60 Hz < 0.28% of Pac,r < 0.24% of Pac,r < 0.22% of Pac,r < 0.22% of Pac,r 18 kHz PVI-USB-RS485_232 (opt.) PVI-AEC-EVO (opt.), AURORA-UNIVERSAL (opt.) PVI-STRINGCOMB (opt.) 16 characters x 2 line LCD display for each module -10...+ 60C/+14...140F with derating above 50C/122F 0...95% non condensing < 78 db (A) @ 1 m < 75 db (A) @ 1 m 1000 m / 3280 ft
IP 20 IP 20 Air Forced Air Forced 6800 m3/h - 4012 CFM 4800 m3/h - 2832 CFM 7600 m3/h - 4484 CFM 5600 m3/h - 3304 CFM 2184mm x 1250mm x 850mm 2184mm x 1250mm x 850mm / 86.0 x 49.2 x 33.5 2184mm x 1250mm x 850mm / 86.0 x 49.2 x 33.5 2184mm x 1250mm x 850mm 1215mm x 1250mm x 870mm / 86.0 x 49.2 x 33.5 1215mm x 1250mm x 870mm / 86.0 x 49.2 x 33.5 / 47.8 x 49.2 x 34.3 (Transf.) / 47.8 x 49.2 x 34.3 (Transf.) < 1600 kg / 3527 lb < 1000 kg / 2205 lb < 1750 kg / 3858 lb < 1150 kg / 2535 lb < 60 kg / 132 lb < 60 kg / 132 lb No Yes No CE CE EN 50178, EN61000-6-2, EN61000-6-4, EN61000-3-11, EN 50178, EN61000-6-2, EN61000-6-4, EN61000-3-11, EN61000-3-12 EN61000-3-12 Enel Guideline, BDEW, RD 1663 Enel Guideline, BDEW, RD 1663 Yes
AURORA PLUS
83
PVI-CENTRAL-50 PVI-CENTRAL-100
84
AURORA PLUS
These Aurora commercial-grade inverters are designed for large solar applications such as apartment buildings and industrial facilities. These extremely scalable modular inverter systems, based on 50kW conversion modules, increase usable power and improve availability. The reduction of performance in any individual inverter will not impact the energyharvesting capabilities of other modules. Industry-leading power conversion efficiencies of up to 95.8%, combined with high-speed Maximum Power Point Tracking (MPPT) channels, optimize energy harvesting across a wide array of operating conditions. Inverter systems are delivered pre-configured and pre-tested, significantly reducing on-site wiring and testing.
Features
Reduced susceptibility to a single fault. In case of a component failure, a maximum of 50kW will be lost Reduced acoustic noise due to the high switching frequency Reverse-polarity protection minimizes potential damage caused by array mis-wiring Maximum input voltage up to 600Vdc, high design flexibility and reduced DC distribution losses for large scale PV plants Integrated DC and AC distribution and protection. Fully equipped for connection, additional accessories not required Easy installation and maintenance procedure. Front extractable DC/AC converters and accessibility to all critical parts High efficiencies deliver more energy Two independent RS-485 communication interfaces - for inverter and intelligent string combiner monitoring Integrated DC disconnect switch for each 50 kW module AC and DC side integrated protection (fuses and OVR) easily replaceable Integrated fuse grounding kit with ground-fault detection and interruption (GFDI)
compliant to UL1741
AURORA PLUS 85
OVR REVERSE POLARITY PROTECTION PV ARRAY 1 (+) PV ARRAY 1 (-) DC FUSE (1) EMC FILTER DC / AC INVERTER LINE FILTER DC BREAKER INVERTER MODULE 50kW CONTACT EMI FILTER AC FUSE
PE
CONTROL CIRCUIT
OVR REVERSE POLARITY PROTECTION PV ARRAY 2 (+) PV ARRAY 2 (-) DC FUSE (1) EMC FILTER DC / AC INVERTER LINE FILTER DC BREAKER INVERTER MODULE 50kW CONTACT EMI FILTER AC FUSE
PE
CONTROL CIRCUIT
AC CONTACTOR
100kVA TRANSFORMER
PE
PVI-CENTRAL-50
100 99 98 97 96 Efficiency, % 95 94 93 92 91 90 0% 10% 20% 30% 40% 50% 60% 70% 80% 90% 100% % of Rated Output Power
330 Vdc 370 Vdc 480 Vdc
PVI-CENTRAL-100
100 99 98 97 96 Efficiency, % 95 94 93 92 91 90 0% 10% 20% 30% 40% 50% 60% 70% 80% 90% 100%
330 Vdc 370 Vdc 480 Vdc
86
AURORA PLUS
PARAMETER
PVI-CENTRAL50-US-208
PVI-CENTRAL100-US-208
PVI-CENTRAL50-US-480
PVI-CENTRAL100-US-480
Input Side Absolute Maximum DC Input Voltage (Vmax,abs) 600 V 600 V MPPT Input DC Voltage Range (VMPPTmin,r ... VMPPTmax,r) 330...600 V 330...600 V MPPT Input DC Range (VMPPTmin,f ... VMPPTmax,f) at Full Power 330...600 V 330...600 V Number of Independent MPPT Master/Slave 1 1 Maximum Combined DC Input Current (Idcmaxc) 170 A 340 A 170 A 340 A Maximum DC Input Current for Each Module (Idcmax,m) 170 A 170 A Number of DC Inputs Pairs 1 2 1 2 DC Connection Type 2 x 3/0 AWG 90 / M10 4 x 3/0 AWG 90 / M10 2 x 3/0 AWG 90 / M10 4 x 3/0 AWG 90 / M10 Input Protection Reverse Polarity Protection Yes, with series diode Yes, with series diode Input Over Voltage Protection - Varistor Yes Yes Photovoltaic Array Isolation Control GFDI (1), According to UL 1741 GFDI (1), According to UL 1741 Fuse Size for Each Input Pair 200A / 600V 200A / 600V Output Side AC Grid Connection Type Three phases () Three phases () Rated AC Power (Pac,r) 50 kW 100 kW 50 kW 100 kW Rated Grid Voltage (Vac,r) 208 V 208 V 480 V 480 V AC Voltage Range (Vacmin...Vacmax) 183...228 V 183...228 V 422...528 V 422...528 V Maximum Output Current (Iac,max) 139 A 278 A 61 A 121 A Rated Frequency (fr) 60 Hz 60 Hz Frequency Range (fmin...fmax) 59.3...60.5 Hz 59.3...60.5 Hz Power Factor (Cosphiac,r) > 0.995 > 0.995 Total Harmonic Distortion < 4% (@ Pac,r) < 3% (@ Pac,r) AC Connection Type 3 x 2/0 AWG 90 / M10 3 x 2/0 AWG 90 / M10 Output Protection Anti-Islanding Protection According to UL 1741 According to UL 1741 Output Overvoltage Protection (Varistor) Yes Yes Night Time Disconnect Yes Yes AC Circuit Breaker Yes / 65 kA Yes / 65 kA Operating Performance Maximum Efficiency (max) 95.6% 95.8% Weithted Efficiency (EURO / CEC) - / 95.0% - / 95.0% Stand-by Consumption/Night-time power loss < 15 W < 30 W < 15 W < 30 W AC Auxiliary Supply 3 x 480 Vac, 50/60 Hz 3 x 480 Vac, 50/60 Hz Auxiliary Supply Consumption < 0.40% of Pac,r < 0.40% of Pac,r Inverter Switching Frequency 18 kHz 18 kHz Communication Wired Local Monitoring PVI-USB-RS485_232 (opt.) PVI-USB-RS485_232 (opt.) Remote Monitoring PVI-AEC-EVO (opt.), AURORA-UNIVERSAL (opt.) PVI-AEC-EVO (opt.), AURORA-UNIVERSAL (opt.) AURORA String Combiner PVI-STRINGCOMB (opt.) PVI-STRINGCOMB (opt.) User Interface 16 characters x 2 lines LCD display for each module 16 characters x 2 lines LCD display for each module Environmental -10...+50C/+14...122F -10...+50C/+14...122F Ambient Temperature Range with derating above 40C/104F with derating above 40C/104F Relative Humidity 0...95 % non condensing 0...95 % non condensing Noise Emission < 62 dB @ 1 m < 62 dB @ 1 m Maximum Operating Altitude without Derating 1000 m / 3280 ft 1000 m / 3280 ft Physical Environmental Protection Rating Nema 1 Nema 1 Cooling Air forced Air forced Required Air Cooling Flow 1500 m3/h - 885 CFM 2000 m3/h - 1180 CFM 1500 m3/h - 885 CFM 2000 m3/h - 1180 CFM 1275mm x 1675mm x 850mm 1275mm x 1675mm x 850mm 1275mm x 1675mm x 850mm 1275mm x 1675mm x 850mm Dimension (H x W x D) / 50.2 x 66.0 x 33.5 / 50.2 x 66.0 x 33.5 / 50.2 x 66.0 x 33.5 / 50.2 x 66.0 x 33.5 Weight 700 kg / 1550 lb 850 kg / 1873 lb 700 kg / 1550 lb 850 kg / 1873 lb Weight of the module < 70 kg / 154 lb < 70 kg / 154 lb Safety Transformer Yes Yes Marking cCSAus cCSAus Safety and EMC Standard UL 1741, CSA - C22.2 N. 107.1-01 UL 1741, CSA - C22.2 N. 107.1-01 Grid Standard IEEE 1547 IEEE 1547
1. Ground Fault Detector Interrupter
AURORA PLUS
87
PVI-CENTRAL-250 PVI-CENTRAL-300
GENERAL SPECIFICATIONS CENTRALIZED MODELS
PVI-CENTRAL-250-US PVI-CENTRAL-300-US PVI-CENTRAL-250-CAN PVI-CENTRAL-300-CAN
88
AURORA PLUS
These Aurora commercial-grade inverters are designed for large solar applications such as apartment buildings and industrial facilities. These extremely scalable modular inverter systems, based on 50kW conversion modules, increase usable power and improve availability. The reduction of performance in any individual inverter will not impact the energyharvesting capabilities of other modules. Industry-leading power conversion efficiencies of up to 97.6%, combined with high-speed Maximum Power Point Tracking (MPPT) channels, optimize energy harvesting across a wide array of operating conditions. Inverter systems are delivered pre-configured and pre-tested in rugged enclosures, significantly reducing on-site wiring and testing. Three independent MPPT input channels offer maximum flexibility and energy harvesting.
Features
Reduced susceptibility to a single fault. In case of a component failure, a maximum of 50kW will be lost Reduced acoustic noise due to the high switching frequency Outdoor enclosure for unrestricted use under any environmental conditions Maximum input voltage up to 600Vdc, high design flexibility and reduced DC distribution losses for large scale PV plants Integrated DC and AC distribution and protection. Fully equipped for connection, additional accessories not required Easy installation and maintenance procedure. Front extractible DC/AC converters and accessibility to all critical parts Two independent RS-485 communication interfaces - for inverter and intelligent string combiner monitoring High efficiency LV isolation transformer Integrated DC disconnect switch for each 50 kW module AC and DC side integrated protection (fuses and OVR) easily replaceable Integrated fuse grounding kit with ground-fault detection and interruption (GFDI)
compliant to UL174
AURORA PLUS 89
DC FUSE
(1)
DC BREAKER
OVR
CONTROL CIRCUIT
DC FUSE
(1)
DC BREAKER
OVR
CONTROL CIRCUIT
DC FUSE
(1)
DC BREAKER
OVR
CONTROL CIRCUIT
DC FUSE
(1)
DC BREAKER
OVR
CONTROL CIRCUIT
AC BREAKER
REVERSE POLARITY PROTECTION PV ARRAY 1 (+) PV ARRAY 1 (-) PE OVR
DC FUSE
(1)
DC BREAKER
+ 24 VDC
480 VAC
R S T PE
CONTROL CIRCUIT
DC FUSE
(1)
DC BREAKER
OVR
CONTROL CIRCUIT
PVI-CENTRAL-250-US
100 99 98 97 96 95 94 93 320 Vac 92 91 90 360 Vac 480 Vac 92 91 90 0% 10% 20% Efficiency, % 100 99 98 97 96 95 94 93
PVI-CENTRAL-300-US
Efficiency, %
0%
10%
20%
30%
40%
50%
60%
70%
80%
90%
100%
30%
40%
50%
60%
70%
80%
90%
100%
90
AURORA PLUS
PARAMETER
PVI-CENTRAL250-US
PVI-CENTRAL300-US
PVI-CENTRAL250-CAN
PVI-CENTRAL300-CAN
Input Side Absolute Maximum DC Input Voltage (Vmax,abs) 600 V 600 V MPPT Input DC Voltage Range (VMPPTmin,r ... VMPPTmax,r) 320...600 V 320...600 V MPPT Input DC Range (VMPPTmin,f ... VMPPTmax,f) at Full Power 320...550 V 320...550 V Number of Independent MPPT Multi - Master/Slave 3 3 Maximum Combined DC Input Current (Idcmaxc) 850 A 1020 A 850 A 1020 A Maximum DC Input Current for Each Module (Idcmax,m) 170 A 170 A Number of DC Inputs Pairs 5 6 5 6 DC Connection Type 10 x 350 kcmil 90 / M10 12 x 350 kcmil 90 / M10 10 x 350 kcmil 90 / M10 12 x 350 kcmil 90 / M10 Input Protection Reverse Polarity Protection YES, with series diode YES, with series diode Input Over Voltage Protection - Varistor Yes Yes Photovoltaic Array Isolation Control GFDI (1), According to UL 1741 GFDI (1), According to UL 1741 Fuse Size for Each Input Pair 200A / 600V 200A / 600V Output Side AC Grid Connection Type Three phases () Three phases () Rated AC Power (Pac,r) 250 kW 300 kW 250 kW 300 kW Rated Grid Voltage (Vac,r) 480 V 480 V 600 V 600 V AC Voltage Range (Vacmin...Vacmax) 423...528 V 528...660 V Maximum Output Current (Iac,max) 315 A 378 A 253 A 303 A Rated Frequency (fr) 60 Hz 60 Hz Frequency Range (fmin...fmax) 59.3...60.5 Hz 59.3...60.5 Hz Power Factor (Cosphiac,r) > 0.995 > 0.995 Total Harmonic Distortion < 3% (@ Pac,r) < 3% (@ Pac,r) AC Connection Type 3 x 350 kcmil 90 / M10 3 x 350 kcmil 90 / M10 Output Protection Anti-Islanding Protection According to UL 1741 According to UL 1741 Output Overvoltage Protection (Varistor) Yes Yes Night Time Disconnect Yes Yes AC Circuit Breaker Yes / 65 kA Yes / 65 kA Operating Performance Maximum Efficiency (max) 97.6% 97.6% Weithted Efficiency (EURO / CEC) 97.6 / 97.2% 97.6 / 97.2% Stand-by Consumption/Night-time power loss < 105 W < 120 W < 105 W < 120 W AC Auxiliary Supply 3 x 480 Vac, 50/60 Hz 3 x 480 Vac, 50/60 Hz Auxiliary Supply Consumption < 0.30% of Pac,r < 0.35% of Pac,r < 0.30% of Pac,r < 0.35% of Pac,r Inverter Switching Frequency 9 kHz 9 kHz Communication Wired Local Monitoring PVI-USB-RS485_232 (opt.) PVI-USB-RS485_232 (opt.) Remote Monitoring PVI-AEC-EVO (opt.), AURORA-UNIVERSAL (opt.) PVI-AEC-EVO (opt.), AURORA-UNIVERSAL (opt.) AURORA String Combiner PVI-STRINGCOMB (opt.) PVI-STRINGCOMB (opt.) User Interface TFT LCD 5.7 TFT LCD 5.7 Environmental -25...+60 C / -13...+140F -25...+60 C / -13...+140F Ambient Temperature Range with derating above 50C / 122F with derating above 50C / 122F Relative Humidity 0...100 % condensing 0...100 % condensing Noise Emission < 62 dB @ 1 m < 62 dB @ 1 m Maximum Operating Altitude without Derating 1000 m / 3280 ft 1000 m / 3280 ft Physical Environmental Protection Rating Nema 3R Nema 3R Cooling Air forced Air forced 8000 m3/h - 4720 CFM 7000 m3/h 8000 m3/h Required Air Cooling Flow 7000 m3/h - 4130 CFM Dimension (H x W x D) 2147mm x 2933mm x 1250mm / 84.5 x 115.7 x 49.3 2147mm x 2933mm x 1250mm / 84.5 x 115.7 x 49.3 Weight < 2495 kg / 5500 lb 2722 kg / 6000 lb < 2495 kg / 5500 lb 2722 kg / 6000 lb Weight of the module < 70 kg / 154 lb < 70 kg / 154 lb Safety Transformer Yes Yes Marking cCSAus cCSAus Safety and EMC Standard UL 1741, CSA - C22.2 N. 107.1-01 UL 1741, CSA - C22.2 N. 107.1-01 Grid Standard IEEE 1547 IEEE 1547
1. Ground Fault Detector Interrupter
AURORA PLUS
91
92
AURORA PLUS
ULTRA
AURORA PLUS
93
ULTRA
GENERAL SPECIFICATIONS CENTRALIZED MODELS
ULTRA-700.0-TL ULTRA-1050.0-TL ULTRA-1400.0-TL
NEW
94
AURORA PLUS
The largest solar power inverter in the Power-One Aurora product range, the new Ultra 1.4MW unit is designed with large utility-grade installations in mind. This liquid-cooled, high-powered Aurora inverter is the largest PV inverter available in the market. The compact chassis gives maximum power for the minimum footprint. Industry-leading power conversion efficiencies of up to 98.7%, combined with high-speed Maximum Power Point Tracking (MPPT) channels, optimize energy harvesting across a wide array of operating conditions. Up to four independent MPPT input channels offer maximum flexibility and energy harvesting. This large inverter system significantly reduces the wiring requirements and on-site testing thanks to the presence of separated and dedicated compartments for DC and AC.
Features
High performance utility grade inverter for large utility PV installations with 98.7% efficiency Outdoor enclosure for unrestricted use under any environmental conditions Passive liquid cooling with total segregation of internal compartments assuring a 5-year maintenance cycle Reduced susceptibility to a single fault. In case of a component failure, a maximum of 350kW will be lost Extended MPPT input voltage range Direct transformerless conversion to the 690 Vac output reduces AC distribution cost Maximum input voltage up to 1100 Vdc, high design flexibility and reduced DC distribution losses for large scale PV plants Integrated DC and AC distribution and protection. Fully equipped for connection, additional accessories not required Easy installation and maintenance procedure. Front extractible DC/AC converters and accessibility to all critical parts Ethernet communication and two independent RS-485 communication interfaces for inverter and intelligent string combiner monitoring Compliant to BDEW and FERC 661
AURORA PLUS 95
PV ARRAY 1(+) PV ARRAY 2(+) PV ARRAY 3(+) PV ARRAY 4(+) PV ARRAY 5(+) PV ARRAY 6(+) PV ARRAY 1(-) PV ARRAY 2(-) PV ARRAY 3(-) PV ARRAY 4(-) PV ARRAY 5(-) PV ARRAY 6(-)
INVERTER MODULE 350kW DC BREAKER OVR BULK CAPS MODULE DC / AC INVERTER MODULE LINE FILTER MODULE AC CONTACT MODULE EMI FILTER AC FUSE
CONTROL CIRCUIT
INVERTER MODULE 350kW OVR DC BREAKER BULK CAPS MODULE DC / AC INVERTER MODULE LINE FILTER MODULE AC CONTACT MODULE EMI FILTER
PV ARRAY 19(+) PV ARRAY 20(+) PV ARRAY 21(+) PV ARRAY 22(+) PV ARRAY 23(+) PV ARRAY 24(+) PV ARRAY 19(-) PV ARRAY 20(-) PV ARRAY 21(-) PV ARRAY 22(-) PV ARRAY 23(-) PV ARRAY 24(-)
Efficiency, %
AC FUSE
CONTROL CIRCUIT
INVERTER MODULE 350kW OVR DC BREAKER BULK CAPS MODULE DC / AC INVERTER MODULE LINE FILTER MODULE
CONTROL CIRCUIT
INVERTER MODULE 350kW OVR DC BREAKER BULK CAPS MODULE DC / AC INVERTER MODULE LINE FILTER MODULE AC CONTACT MODULE EMI FILTER AC FUSE
CONTROL CIRCUIT
PVI-ULTRA
99,0% 98,5% 98,0% 97,5% 97,0% 96,5% 96,0% 95,5% 95,0% 94,5% 0% 10% 20% 30% 40% 50% 60% 70% 80% 90% 100% 650 Vdc
96
AURORA PLUS
PARAMETER
Input Side Absolute Maximum DC Input Voltage (Vmax,abs) MPPT Input DC Voltage Range (VMPPTmin,r ... VMPPTmax,r) MPPT Input DC Range (VMPPTmin,f ... VMPPTmax,f) at Full Power Number of Independent MPPT Multi-Master Number of Independent MPPT Multi - Master/Slave Maximum Combined DC Input Current (Idcmaxc) Maximum DC Input Current for Each Module (Idcmax,m) Number of DC Inputs Pairs DC Connection Type Input Protection Reverse Polarity Protection Input Over Voltage Protection - Varistor Photovoltaic Array Isolation Control Fuse Size for Each Input Pair Output Side AC Grid Connection Type Rated AC Power (Pac,r) Rated Grid Voltage (Vac,r) AC Voltage Range (Vacmin...Vacmax) Maximum Output Current (Iac,max) Rated Frequency (fr) Frequency Range (fmin...fmax) Power Factor (Cosphiac,r) Total Harmonic Distortion AC Connection Type Output Protection Anti-Islanding Protection Output Overvoltage Protection (Varistor) Night Time Disconnect AC Switch AC Fuse for each module Operating Performance Maximum Efficiency (max) Weithted Efficiency (EURO / CEC) Stand-by Consumption/Night-time power loss AC Auxiliary Supply Auxiliary Supply Consumption Auxiliary Supply Consumption without Cooling Inverter Switching Frequency Communication Wired Local Monitoring Remote Monitoring AURORA String Combiner User Interface Environmental Ambient Temperature Range Relative Humidity Noise Emission Maximum Operating Altitude without Derating Physical Environmental Protection Rating Cooling Required Air Cooling Flow Dimension (H x W x D) Weight Weight of the module Safety Transformer Marking Safety and EMC Standard Grid Standard
1. The AC voltage range may vary depending on specific country grid standard 2. The Frequency range may vary depending on specific country grid standard 3. Power factor variations beyond 0.9 imply a reduction of the active power
ULTRA-700.0-TLOUTD-690
ULTRA-1050.0-TLOUTD-690
1100 V 470...1000V 550...900 V 3 2 1240 A + 620 A 620 A 18 18 x 50mm2 (M8)...185mm2(M10) Yes, via input breaker 2 for each module According to local standard 125 A / 1100 V Three phases () 1050 kW 690 V 621...759 V (1) 876 A 50/60 Hz 47...53 / 57...63 Hz (2) > 0.995 (adj. 0.90) (3) < 3% (@ Pac,r) 3 x 240 mm2 (M12) According to local standard Yes Yes Yes 3x350A
ULTRA-1400.0-TLOUTD-690
700 kW
1400 kW
584 A
1168 A
98.7% 98.2% / 98.0% < 90 W 3 x 400 Vac +N, 50/60 Hz < 0.65% of Pac,r < 0.08% of Pac,r 7,5 KHz
98.7% 98.2% / 98.0% < 135 W 3 x 400 Vac +N, 50/60 Hz < 0.50% of Pac,r < 0.08% of Pac,r 7,5 KHz PVI-USB-RS485_232 (opt.) PVI-AEC-EVO (opt.), AURORA-UNIVERSAL (opt.) PVI-STRINGCOMB (opt.) TFT LCD 5.7
98.7% 98.2% / 98.0% < 180 W 3 x 400 Vac +N, 50/60 Hz < 0.65% of Pac,r < 0.08% of Pac,r 7,5 KHz
-20...+ 60C/-4...140F with derating above 50C/122F -40...+ 60C/-40...140F with derating above 50C/122F (opt.) 0...100% condensing < 78 dB(A) @ 1 m 1000 m / 3280 ft IP 65 Passive liquid and air forced Not applicable 2938mm x 3700mm x 1520mm / 115.7 x 145.7 x 59.9 < 2500 kg / 5521 lb < 55 kg / 121 lb
No CE EN 50178, EN61000-6-2, EN61000-6-4, EN61000-3-11, EN61000-3-12 Enel Guideline, BDEW, FERC 661
AURORA PLUS
97
98
AURORA STATION
STATION
AURORA STATION
99
STATION
PVI-STATION
Power-Ones turnkey solution allows large installation customers to select their power inverter solution to be custom-fitted into a prefabricated weatherproof cabin to allow for simple and speedy installation in the field. There are many tailor-made options available for rated power between 440kW and 1.3 MW. The major benefit of this product is the high power-low space ratio and its ability to configure to specific customer requirements such as multiple MPPTs. This product maximizes efficiencies and reliability by using the new Aurora Central inverters, liquid filled MV transformers. The modular format of the Aurora central inverters along with a unique easy-out, easy-in rack system allows for simple maintenance in all weather conditions.
Features
Turnkey solution for PV plants Rated power between 440kW and 1.3 MW Very compact design Best in class efficiency thanks to the use of new generation Power-One inverters and mineral
liquid insulated MV transformers Maximum flexibility thanks to the different inverter size and technology
100
AURORA STATION
STANDARD STATION FOR NORTH AMERICA (MULTI-MASTER CONFIGURATION WITH FLOATING ARRAY)
PVI-330.0-TL L1 L2 L3 PM6 INV AUX1 MV TRANSFORMER TO GRID 320 V / MEDIUM VOLTAGE
STANDARD STATION FOR NORTH AMERICA (MULTI-MASTER CONFIGURATION WITH FLOATING ARRAY)
PVI-330.0-TL L1 L2 L3 PM6 INV AUX1 MV TRANSFORMER TO GRID
PM1
PM1
PM1
PVI-330.0-TL
PM1
PVI-330.0-TL
PM1
PVI-330.0-TL
PM1
PVI-330.0-TL
PM1
PVI-330.0-TL
PVI-330.0-TL
100,00 99,00 98,00 97,00 96,00 95,00 94,00 550Vdc 93,00 92,00 91,00 90,00 0% 485Vdc 500Vdc
Efficiency [%]
10%
20%
30%
40%
50%
60%
70%
80%
90%
100%
AURORA PLUS
101
PARAMETER
Inverter Type Input Side MPPT Input range (VMPPTmax,r...VMPPTtmin,r) MPPT Input range (VMPPTmax,f-VMPPTmin,f ) at full power Absolute Maximum Input Voltage (Vmax,abs) Number of Independent MPPT Multi-Master Number of Independent MPPT Master/Slave Number of Independent MPPT Multi-Master/Slave Maximum Combined Input Current (Idcmax,c) Number of DC Inputs Pairs Available Products Variants -US version for North America -IT version for Italy -DE version for Germany Output Side Inverter Rated Power (Pac,r) -US version Rated Output Voltage (Vac,r) -IT version -DE version Rated Frequency (fr) Nominal Power Factor (Cosphiac,r) Operating Performance (Inverter) Maximum Efficiency (max) Weighted Efficiency (EURO) Transformer -US version Type -IT/DE version -US version Cooling Class -IT/DE version Communication Local Monitoring System -US/IT/DE version Remote Control -US/IT/DE version -US version SCADA System -IT/DE version Environmental Ambient Temperature Range Inverter Station
STATIONPLUS-440.0
2 x PVI-220.0-TL
STATIONPLUS-550.0
1 x PVI-330.0-TL 1 x PVI-220.0-TL
STATIONPLUS-660.0
2 x PVI-330.0-TL 475...950 V 475...850 V 1000 V 12 6 2 1488 A 12 660 kW 3 x 4.16...35 kV 3 x 15...20 kV 3 x 10...20 kV 50/60 Hz > 0.995 (adj. 0.90) 98.0% 97.7%
STATIONPLUS-770.0
1 x PVI-330.0-TL 2 x PVI-220.0-TL
STATIONPLUS-880.0
2 x PVI-330.0-TL 1 x PVI-220.0-TL
8 4 2 992 A 8 440 kW
10 5 2 1240 A 10 550 kW
14 7 3 1736 A 14 770 kW
16 8 3 1984 A 16 880 kW
3 Phase, Oil Filled Mineral/Dry Type ONAN (for Oil Filled Fransformer), Air Cooled (for Dry Transformer) 1 x RS-485 (inc.) PVI-AEC-EVO (opt.), AURORA-UNIVERSAL (opt.) Optional -10...+60C/+14...140F with derating above 50C/122F -10...+60C/+14...140F 0...95% non condensing 1000 m / 3280 ft Sandwich Frame and Standing Seam Roof or Vibrated Reinforced Concrete Vibrated Reinforced Concrete Concrete (Platform for Sandwich Type), Foundation Tank (for Concrete-Made Station) IP 54 CE EN 50178, EN61000-6-2, EN61000-6-4, EN61000-3-11, EN61000-3-12 Enel Guideline, BDEW, RD 1663
Relative Humidity Maximum Operating Altitude without Derating Physical -US version -IT version Construction -DE version -US version Mounting -IT/DE version -US version Environmental Protection Rating -IT/DE version Standard Inverter
102
AURORA STATION
STATIONLITE-500.0
1 x PVI-500.0-TL
STATIONLITE-1000.0
2 x PVI-500.0-TL
STATIONLITE-1500.0
3 x PVI-500.0-TL
STATIONLITE-2000.0
4 x PVI-500.0-TL
475...950 V 475...850 V 1000 V 18 9 3 2214 A 18 990 kW 20 10 4 2480 A 20 22 11 4 2728 A 22 24 12 4 2976 A 24 1320 kW 2 1 1 550 A 5 500 kW 4 2 2 1100 A 10 -
1100 kW 1210 kW 3 x 4.16...35 kV 3 x 15...20 kV 3 x 10...20 kV 50/60 Hz > 0.995 (adj. 0.90) 98.0% 97.7%
1000 kW 1500 kW 3 x 4.16...35 kV 50/60 Hz > 0.995 (adj. 0.90) 98.50% 98.20% 3 Phase Pad-Mounted, Oil Filled Biodegradable KNAN 1 x RS 485 (inc.) PVI-AEC-EVO (opt.), AURORA-UNIVERSAL (opt.) Optional -20...+55C/-4...131F with derating above 45C/113F -20...+55C/-4...131F 0...95% non condensing 1000 m / 3280 ft
3 Phase Pad-Mounted, Oil Filled Biodegradable 3 Phase, Oil Filled Mineral/Dry Type KNAN ONAN (for Oil Filled Fransformer), Air Cooled (for Dry Transformer) 1 x RS-485 (inc.) PVI-AEC-EVO (opt.), AURORA-UNIVERSAL (opt.) Optional -10...+60C/+14...140F with derating above 50C/122F -10...+60C/+14...140F 0...95% non condensing 1000 m / 3280 ft Steel Frame with Aluminum Wall Skin and Standing Seam Roof Sandwich Frame and Standing Seam Roof or Vibrated Reinforced Concrete Vibrated Reinforced Concrete Pad-Mount or Pier-Mount Concrete (Platform for Sandwich Type), Foundation Tank (for Concrete-Made Station) NEMA 3R IP 54 CE EN 50178, EN61000-6-2, EN61000-6-4, EN61000-3-11, EN61000-3-12 Enel Guideline, BDEW, RD 1663
Steel Frame with Aluminum Wall Skin and Standing Seam Roof Pad-Mount or Pier-Mount NEMA 3R CQC, CE EN 50178, EN 61000-6-2, EN 61000-6-4, IEC 62109-1 CNCA/CTS0004, GB/T 19943, IEC 62116
AURORA STATION
103
104
AURORA VISION
VISION
AURORA VISION
105
VISION
106
AURORA VISION
The rules for managing solar electric power production turn traditional business operations on its head. Solar power plants are highly distributed, with each site generating far less power than a nonrenewable power plant. In addition, plants are typically distributed over large geographic areas and may be managed by off-site staff. Operating profit margins are narrow in the solar electric industry, and plants must operate at 98% uptime and produce more than 95% of expected output. With these constraints, failures can be expensive. Small defects (string faults or panel soiling, for example) and inaccurate problem diagnosis can eat up an entire downtime budget or worse. Catastrophic failures, such as damaged inverters, could mean days or weeks offline. No plant operator can afford this type of exposure. Maximum Uptime, Increased Return on Investment and Peace of Mind In 2010, Power-One acquired the technology of leader remote monitoring provider for renewable energy systems Fat Spaniel Technologies. All Power-Ones existing monitoring and control products and services now feature alongside the Fat Spaniel solutions to address renewable energy information needs. These combined products, services and solutions fall under the new category Aurora Vision. There is also an additional premium offering called Fat Spaniel Prime Edition focused on advanced data analysis and visualization of performance across installations. Aurora Vision has three key offerings: Software, Hardware and Accessories. Aurora Vision software includes a full range of system fault management, diagnostics, asset tracking, performance index and alerting services to enable O&M service providers to maximize system energy output while minimizing costs. Other digital services available include revenue information such as billing data, Renewable Energy Certificate (REC) reporting, performance-based incentive (PBI) reporting and XML data feeds. Web-based energy production and conservation metrics, displayed via Internet-connected PCs and kiosks in high traffic areas, such as building lobbies or retail sites, provides an effective way to market clean energy. The hardware section of Aurora Vision includes the equipment designed to capture data and environmental information to allow the transferral between inverter, installation and owner. A key product is the Aurora Universal which is installed at the PV plant. This section also includes inverter add-ons such as string-combiner boxes and the EVO easy control box. Accessories include monitoring equipment such as the Desktop monitoring system and the EVO Easy Control. Providing the complete panel to grid system solution is the key objective for Power-One. The Aurora Vision services will help maximize the return on investment of renewable energy projects through the better understanding and communication between the user and the installation.
AURORA VISION
107
AURORA VISION
GENERAL SPECIFICATIONS
Features
Real Time Visibility - Aurora Vision provides highly interactive and real-time access to key performance and operations metrics to help plant management optimize operational decisions. Over 4,100 plants supporting an aggregate of 240 MW power generated use Aurora Vision for monitoring and management. Scalable and Secure Platform - Field-tested, scalable and secure architecture supports over 10 million plant operations transactions per day and trusted by U.S. utility- and environmental regulatory agencies to enable prompt and accurate financial rebate processing. Extensible & Modular Solution - Modular design enables extensibility of the platform to support Easy integration with Aurora Universal platform and other popular inverters to increase diagnostic capability, reduce non-compliance risk, and enable plant uptime of 98%+.
108
AURORA VISION
PARAMETER
PORTFOLIO DASHBOARD Overview Granularity ASSET MANAGEMENT Overview Plant Summary Asset Details EVENT MANAGEMENT Overview Profile Management REPORTING Standard Reporting Custom Reporting Agency Reporting ANALYTICS Overview
Portfolio level view of power, energy, plant status, and active events Daily, weekly monthly and yearly summarization of key performance indicators Portfolio level view of assets by location, status (severity of active events) and system size Operational level summary of each plant available as daily, weekly, month and yearly summaries Not applicable Manage asset details, report generation, event log analysis and plant sharing capabilities at individual plant level
Monitor and manage critical event data such as severity, plant, asset, type, duration, start, end, notify, acknowledge and notes System default profile only Unlimited profile generation and associate events and corresponding basic/advanced severity levels View and export standard operational reports across the plant portfolio Create, view and export custom operational reports across the plant portfolio
Log of agency reports submitted by plant, by agency, by calendar period Not applicable Perform advanced data analysis and visualization of performance across plants
Block Diagram
AURORA VISION
109
AURORA UNIVERSAL
GENERAL SPECIFICATIONS
NEW
110
AURORA VISION
The Aurora Universal System is a high-performance, customer-premises data management platform for renewable energy plant operations, revenue-grade metering, and smart grid integration. Aurora Universal interoperates with multi-vendor balance-of-system equipment including inverters, string combiners, meters, and environmental systems, delivering high-frequency/highaccuracy data sampling and high reliability. Together with Power-Ones Aurora Vision and Fat Spaniel Prime edition software-as-a-service management solutions, Aurora Universal helps simplify operational management and ensure availability of distributed power plants.
Features
Unified Interoperable Platform
A unified plant data management platform that seamlessly integrates balance-of-system components (inverters, string combiners, environmental systems) from Power-One and a widerange of 3rd Party vendors. Provides out-of-box integration with Aurora Vision and Fat Spaniel Prime Software-as-a-Service solutions for fast installation and instant plant management.
Field-tested, scalable and secure architecture enables reliable real-time revenue-grade energy monitoring and management.
Modular design enables extensibility of the platform to support wide range of multi-vendor devices and applications from residential to utility environments.
111
VISION
Aurora Universal Revenue Grade: for high-accuracy energy management and metering for power plants of up to 2 MW in capacity (or segments thereof) Aurora Universal Industrial: for continuous monitoring of popular string and central Inverter models Aurora Universal Residential: for continuous monitoring of popular residential inverter models
18 36 Vdc
RS485_1
RS485_2
ETHERNET_1
CT ETHERNET_2 Reserved
Block Diagram
112
AURORA VISION
PARAMETER
PORTFOLIO DASHBOARD Computing Environment Interoperability Data Sampling Rate Real-Time Management Upgradability COMMUNICATIONS Serial Port 1 Serial Port 2 Maximum Devices Per Serial Port Ethernet 1 Ethernet 2 PROTOCOLS Plant Network Transport Protocols Support LAN/WAN Protocols REVENUE GRADE SUPPORT Revenue Grade Meters CT Integration POWER SUPPLY DC Power Supply Input ENVIRONMENTAL PARAMETERS Ambient Temperature Range Environmental Protection Rating Relative Humidity ENVIRONMENTAL PARAMETERS Dimension Weight
High performance platform and Fat Spaniel Open Premise Platform software Multi-Vendor Interoperability with popular renewable energy vendors and product models High Frequency Data Sampling 1 minute average that can be varied to meet application requirements Compatible with Aurora Vision and Fat Spaniel Prime Software-as-a-Service solutions for real-time performance management and reporting Field Upgradable over the Internet RS485 interface for Power-One Aurora (or Modbus) devices RS485 interface for 3rd party devices (Modbus or proprietary) 15 per RS485 (recommended) 10/100 BaseT Ethernet for WAN and LAN communications Reserved Modbus/RTU, Modbus/TCP, SunSpec and vendor-specific TCP/IP, HTTP, DHCP, SSL Integrated revenue grade meter (meets ANSI C.12 for 98%+ accuracy) Optional 5A CTs allowing for a wide range of current sizes (ordered separately) Not applicable Not applicable 90...575 VAC, 50/60 Hz -20...+55C / -4...+131F NEMA 4X <90% Non-Condensing 393.4mm x 352.0mm x 161.0mm / 15.2 x 13.9 x 6.3 < 3.6 kg / 7.9 lb -20...+55C / -4...+131F NEMA 4X <90% Non-Condensing 393.4mm x 352.0mm x 161.0mm / 15.2 x 13.9 x 6.3 < 3.6 kg / 7.9 lb -10...+40C / 14...+104F Indoor only Not applicable 77.0mm x 111.0mm x 26.0 mm 3.03 x 4.4 x 1.0 < 0.2 kg / 0,4 lb Not applicable Not applicable
AURORA VISION
113
PVI-STRINGCOMB PVI-STRINGCOMB-US
GENERAL SPECIFICATIONS CENTRALIZED MODELS
PVI-STRINGCOMB PVI-STRINGCOMB-US
114
AURORA VISION
The Aurora PVI-STRINGCOMB string combiner box is an ideal complement to the Aurora commercial and utility grade inverter that ensures the same monitoring accuracy of the PV generator typically achieved with string inverters. Up to 10 channels of individual or paired string currents can be accurately monitored via hall effect sensors, and any issue detected promptly signaled to the managing inverter and the system supervisor to allow prompt detection of the faulty strings. All string combiner boxes include surge protection with removable elements as well as fuse protection for each couple of string channels. It is available with a fully-integrated DC switch (optional on -S version), fuse and remote controlled DC disconnect function.
Features
Up to 20 strings directly connectable Cartridge fuse on each input for over current protection 10 Hall-effect current sensors for fast and precise monitoring and fault diagnostic Integrated DC disconnection switch (-US and -S version) Rugged watertight powder-coated aluminum enclosure RS485 serial bus for communication with the central inverter 4 analog inputs for ambient sensors: temperature, irradiance, wind speed, anti-theft Available fuse size: 10A, 12A, 16A, 20A Internal auxiliary power supply and additional output for external auxiliary (-S Version) Overvoltage protection on DC power line and signals via replaceable varistors (-S Version)
AURORA VISION
115
VISION
-S VERSION DC BREAKER
S19 (+) S20 (+) INPUT STRING CONNECTORS FUSE STATUS CURRENT SENSE V
S1(+) S2 (+)
WIND
FUSE STATUS
CURRENT SENSE
+ RS485
SENSORS
EXTERNAL SERVICES
CONTROL UNIT
- RS485
ANTI-THEFT ALARM
Block Diagram
116
AURORA VISION
PARAMETER
Input Side DC Input String Voltage Range Absolute Maximum DC Input String Voltage Maximum DC Current for Each Measurement Channel Measument Channels Strings for Each Measurement Channel Maximum Number of Input Strings Number of Input String for Each Fuse String Cable Cross Section Output Side Maximum Output Current Output Cable Connection Ground Connection Cable Output DC Switch Rating Communication User Interface Features Anti-theft Alarm (opt.) Anemoter Sensor Monitoring (opt.) Temperature Sensor Monitoring (opt.) Reference PV Cell Monitoring (opt.) Data Monitoring String Currents String Fuse Status Ambient Parameters Overvoltage status Environmetal Parameters Ambient Temperature Range Relative Humidity Maximum Operating Altitude without Derating Environmental Protection Rating Cooling Enclosure Dimension (H x W x D) Weight Warranty Safety Marking Safety and EMC Standard Available Products Variants 10 A x 20 input strings or 20 A x 10 input strings 10 A x 20 input strings or 20 A x 10 input strings with DC switch
AURORA STRINGCOMB
250 850 V 1000 V 20.0 A 10 2 20 2 6 mm2 max. 160.0 A 1 x M10 (200 mm2 max.) 1 x M8 (350 mm2 max.) Not available 1 x RS485 Yes Yes Yes Yes Yes Yes Yes Yes -25...+55C / -13...131F 0...100 % condensing 1000m / 3280 ft IP 65 Natural Aluminun Powder-Coated 559mm x 757mm x 250mm / 22.0 x 29.8 x 9.8 < 23 kg / 50.7 lb 5year standard 10/15/20 optional CE EN 50178, EN 61000-6-2, EN 61000-6-4 PVI-STRINGCOMB Not available
AURORA STRINGCOMB-S
250 850 V 1000 V 20.0 A 10 2 20 2 6 mm2 max. 125.0 A 1 x M10 (200 mm2 max.) 1 x M8 (350 mm2 max.) 125 A / 1,000 V 1 x RS485 Yes Yes Yes Yes Yes Yes Yes Yes -25...+55C / -13...131F 0...100 % condensing 1000m / 3280 ft IP 65 Natural Aluminun Powder-Coated 559mm x 757mm x 250mm / 22.0 x 29.8 x 9.8 < 25 kg / 55.1 lb 5year standard 10/15/20 optional CE EN 50178, EN 61000-6-2, EN 61000-6-4 Not available PVI-STRINGCOMB-S
AURORA VISION
117
S1(+) S2 (+)
CURRENT SENSE
DC BREAKER STATUS
PV FIELD
CONTROL UNIT
- RS485
S1(-) S2 (-)
GROUNDED CONDUCTOR
S19 (-)
REFERENCE AMBIENT TEMPERATUR TEMPERATURE WIND
S20 (-)
SENSORS
M/S C W/SM
EXTERNAL SERVICES
ANTI-THEFT ALARM
Block Diagram
118
AURORA VISION
PARAMETER
Input Side DC Input String Voltage Range Absolute Maximum DC Input String Voltage Maximum DC Current for Each Measurement Channel Measument Channels Strings for Each Measurement Channel Maximum Number of Input Strings Number of Input String for Each Fuse String Cable Cross Section Output Side Maximum Output Current Output Cable Connection Ground Connection Cable Output DC Switch Rating Communication User Interface Features Anti-theft Alarm (opt.) Anemoter Sensor Monitoring (opt.) Temperature Sensor Monitoring (opt.) Reference PV Cell Monitoring (opt.) Data Monitoring String Currents String Fuse Status Ambient Parameters Overvoltage status Environmetal Parameters Ambient Temperature Range Relative Humidity Maximum Operating Altitude without Derating Environmental Protection Rating Cooling Enclosure Dimension (H x W x D) Weight Warranty Safety Marking Safety and EMC Standard Available Products Variants 10 A x 20 input strings or 20 A x 10 input strings
AURORA STRINGCOMB-US
250 600 V 600 V 20.0 A 10 2 20 1 AWG 20 6 200 A 2 x 300 kcmil (Each Pole) 2 x 300 kcmil 200 A / 600 V 1 x RS485 Yes Yes Yes Yes Yes Yes Yes Yes -25...+55C / -13...131F 0...100 % condensing 1000m / 3280 ft NEMA 4X Natural Aluminun Powder-Coated 800mm x 655mm x 246mm / 31.5 x 25.8 x 9.7 < 30.4 kg / 67 lb 5year standard 10/15/20 optional cCSAus UL 1741, CSA-C22.2 No. 107.1-01 PVI-STRINGCOMB-US
AURORA VISION
119
AURORA ENVIRONMENTAL
GENERAL SPECIFICATIONS
NEW
Features
The Aurora Environmental Meteorological Measurement System consists of a Meteorological Module (MM) and a Power Distribution and Communications Module (PDCM). The Aurora Environmental system automatically monitors site meteorological conditions and photovoltaic panel temperature in real-time, transmitting sensor measurements to the FST data center for site status monitoring and management. The Aurora Environmental is delivered ready for installation and use; only requiring the installer to mechanically mount the modules on a user supplied mast, connect AC power to the PDCM, and initialize an automatic system configuration process. No special tools, software, or on-site calibration is required.
120
AURORA VISION
PARAMETER
Sensors Wind Speed Wind Direction Rainfall Relative Humidity Solar Radiation Air Temperature Range PV Panel Temperature Range Dimensions (Maximums including sensors and mounting bracket) Dimension (H/L/W) Packaged Weight Packaged
459.0mmm x 559.0mm x 310.0mm / 18.1 x 22.0 x 12.2 559.0mm x 559.0mm x 381.0mm / 22.0 x 22.0 x 15.0 2.31 kg / 5.0 lb 5.44 kg / 12.0 lb
PARAMETER
General Internal Module Certifications Operating Temperature Relative Humidity Inputs & Outputs Input Power Output Power (to MM) Data Input Data Output Packaged Dimensions L/W/H Packaged Weight Packaged
PVI-AEC-EVO
GENERAL SPECIFICATIONS EASY CONTROL
PVI-AEC-EVO
Features
The Easy Control data logger links Power-One inverters and balance-of-system components over
the Internet to performance monitoring and management systems such as Aurora Vision and Fat Spaniel Prime Edition.
Connects up to 128 Power-One devices using RS485 communications for low-frequency data
sampling.
Collects performance information such as energy harvest, power, voltage and inverter status.
122
AURORA VISION
PARAMETER
Communication Inverter Communication (Port 1) Additional Inverter Communication (Port 2) Maximum Number of AURORA Devices (1) PC Communication Features Configurable Analog Inputs Temperature Analog Input Configurable Digital Inputs Digital Outputs Digital Outputs Configurable Power Supply AC/DC Power Supply
PVI-AEC-EVO
1 x RS485 1 x RS485 Configurable as Interface to Aurora 64xstringinverters or 32x55kW conversion module (central inverter) for Each RS485 Ethernet 10/100Mbps 2 configurable as 0 to 10 Vdc or 4 to 20 mA 1 x PT100 or PT1000 Sensor with Autosetting 4 x Opto Isolated as Status Inputs (for Alarms) or Power Management (PM) Control Signals 2 x Opto Isolated as Status Inputs or Pulse Converter Inputs (from Energy Meter) 3 x Relais Power Contacts 230 V / 3 A 2 x Opto Isolated (27 V, 50 mA) Output Status or Pulse Output Input: 100...240 VAC, 50/60 Hz - Output: 24 VDC, 0.75 A 18...48 VDC, 1 A < 7,5 W Lithium Type Li2032
Maximun Consumption Battery for Integrated Clock Environmental Parameters Ambient Temperature Range -20...+55C (-13...131F) Environmental Protection Rating IP20 Relative Humidity < 90% Non Condensing Mechanical Dimensions H x W x D 190mm x 90mm x 63mm / 3.54 x 6.30 x 2.48 - 9 Modules Weight < 0.36 kg / 0.80 lb Mounting System 35 mm Top Hat DIN Rail (EN50022) Available Product Variants Standard PVI-AEC-EVO Accessories (Ordering Code) Power Supply Yes Irradiance Sensor 0 - 10V (PVI-AEC-IRR) Optional Irradiance & Module Temp. Sensor 0 - 10V (PVI-AEC-IRR-T) Optional PT-100 Self-Adhesive Sensor (PVI-AEC-T100-ADH) Optional PT-100 Signal Converter, 24 V supply (PVI-AEC-T100-24V) Optional PT-1000 Sensor in case with Integrated Converter (PVI-AEC-T1000-INTEGR) Optional Wind Speed Sensor - Anemometer (PVI-AEC-WIND) Optional SD Card (1GB) Yes Safety Marking CE Safet and EMC standard PVI-AEC-EVO: EN 60950, EN 55022, EN 55024 (1) AURORA Devices are AURORA String Inverters and Modules for CENTRAL AURORA Inverter. Monitoring of String Comb is done via Strincomb Manager Module configured in Central Inverter; the maximum number of STRING COMB for each Stringcomb Manager is 12.
Block Diagram
18 - 36 Vdc INTERNAL POWER SUPPLY SUPPLY BUS + 5 V / 0.5A TX RX KEYBOARD RS485_1
AURORA DEVICES
RS232
DISPLAY
+ T/R - T/R RTN RS485_2 RELAY OUTPUT OPTOISOLATED 250V / 3A
RTN
CPU
2 6 A/D
AURORA VISION
123
PVI-DESKTOP
GENERAL SPECIFICATIONS DESKTOP MODELS
PVI-DESKTOP
Features
Power-Ones PVI-Desktop provides the ability to monitor performance of connected
inverters and is ideal for residential and small commercial PV and wind applications.
In
addition to wired connectivity (via RS-485), the PVI-Desktop system can also be connected to six targets inverters via a wireless RF tranceiver link capable of connectivity anywhere within 960 feet (free field). The wireless communication requires an optional radio tranceiver module to be installed in each inverter.
The system can be linked to a personal computer via Bluetooth (-BT version) or USB
connectivity, and will therefore allow performance monitoring at any location with online access using Aurora Communicator. Energy harvesting data for up to six Aurora inverters can be monitored simultaneously using the PVI-Desktop.
124
AURORA VISION
PARAMETER
Inverter Communication - Radio Radio Communication Maximum Radio Coverage Wired Communication Maximum Wired Conenction PC Communication Wireless Wired Communication Connectivity Compatibility with Inverters Maximum Number of AURORA Inverters Features Data Displaying Parameters Data Storage Parameters Software Upgrade Language Power Supply AC/DC Adapter USB Stand Alone Display Dimensions Color Resolution Type Equipment Stylus Pen AC Adapter USB Cable SD Card (1GB) Environmental Parameters Ambient Temperature Range in C (F) Environmental Protection Rating Relative Humidity Mechanical Dimensions H x W x D Weight Mounting Kit (Desk and Wall) Available Product Variants Standard Bluetooth Safety Marking
PVI-DESKTOP
864 MHz
PVI-DESKTOP-AU
915...927 MHz 300 m / 960 ft Free Space RS485 (Half Duplex 19200 bps) 2000 m / 3280 ft Bluetooth (Optional) USB 2.0 AURORA PVI String Series(1) 6 All Parameters of AURORA Inverters(1) Power and Energy (by SD Card) USB (AURORA COMMUNICATOR) or SD Card IT / EN / ES / DE / FR 5 V, 1 A, 50/60 Hz Yes Rechargeble Li-Ion Battery 3.5 Yes QVGA 320X240 px Integrated Touch Screen Resistive Yes Yes Yes Yes
PVI-DESKTOP-US
915 MHz
IP20
0/+ 40C (32/104F) IP20 < 90% Non Condensing 102mm x 125mm x 35mm / 4 x 5 x 2.1 < 0.4 kg / 0.88 lb Yes
NEMA 1
PVI-DESKTOP PVI-DESKTOP-BT
PVI-DESKTOP-AU PVI-DESKTOP-BT-AU
PVI-DESKTOP-US PVI-DESKTOP-BT-US
CE C-Tick FCC EN 60950, EN 62311, EN 301 489, Safety and EMC Standards AS/NZS 4268 FCC Cfr 47 part 15 EN 50371, EN 300 220, EN 300 328 (1) All AURORA String Series equipped with Radio Transmitter (Optional Feature). Further information about compatibility on the AURORA PVI-DESKTOP FAQ Frequently Asked Question
Desktop Highlights
RS485
915MHz
915MHz
RS485
915MHz
915MHz
RS485
AURORA Desktop
AURORA VISION
125
AURORA INSTALLER
EASY SOFTWARE INTERFACE TOOL FOR WIND TURBINE/INVERTER INTEGRATION FOR SPECIALISTS
This free software works on Windows XP as well as Windows 7 and represents the basic tool for the optimization of the power curve that will reside onto the inverter itself. It will be conveniently used by professionals and OEMs during inverter/turbine characterization, energy production evaluation as well as stability verifier. Curve Uploading Power basic function parameters Adjusting and Warning Logs download Error data every second for development and optimization phases Log time values monitoring, (Vin, Iin, Pin, Freq.in, Vout, Iout, Pout, Freq. Real out, Status, Temperatures, Energy, Leakage Current, Isolation Resistance) Energy Harvest info reading (daily, weekly, monthly, yearly, Total period, lifetime) of the settings changes Log Produces text data files that can be converter and elaborated with Excel Drivers for connection to a PC via Aurora Inverters RS485 or USB ports are available when using Power-One RS485/USB converter.
Dynamically to be improved
4000 3500 3000 2000 1500 1000
Vdc in Pac out
effective power curve loaded Pac, data collection example
FEATURES
2500
Vdc in
400
500
Dynamically stable
4000 3500 3000
Pac out
effective power curve loaded Pac, data collection example
2500
Vdc in
100
200
300
400
500
126
AURORA VISION
AURORA INSTALLER
Download the free software from Power-One official web site: http://www.power-one.com/renewable-energy/file-downloads Latest releases will be published in the same web page. English language only but intuitive menu will drive user in choices. It works whenever connected to a powered up inverter.
AURORA VISION
127
128
AURORA WIND
WIND
WIND
AURORA WIND 129
130
AURORA WIND
Power-One Converter Solutions for Full Conversion Large Wind and Hydro turbines working at variable speeds, geared or direct driven, need a full converter solution. The systems general structure can be modelled with a rectification stage interfacing the generator and an inverter stage facing the grid. Power-One is able to provide flexible solutions in terms of technology whether there is a need of an active front end facing the generator especially in case of direct drive or hybrid turbines or a passive rectification with 6 or 12 pulses operation mode.
G3 ~
G3 ~
Inverter
Inverter
Power Grid
Power Grid
Converter Features - Medium Voltage or 690V solutions - Liquid cooling - Modular solution - Electrolytic capacitors free - Multi-level topology IGBTs based
- IGBT based chopper - Wide range power factor management - State of the Art Control Algorithms - Fiber Optics
Power-One Converter Solutions for Doubly Fed generators DFiG architecture is still the most popular in the market because of its ability to work efficiently in a range of variable speed conditions Power-One is introducing multi-level back to back converters for this application and so able to improve dramatically the performances in terms of efficiency and consequently energy harvesting. Power-One converters for DFiG applications offers a much higher power density giving the possibility of installing the converter in the nacelle.
Power Grid
Converter Features - 690V Multi-level topology IGBTs based - Liquid cooling - Modular solution - Electrolytic capacitors free - IGBT based Active Crowbar - Power factor management - State of the Art Control Algorithms - Fiber Optics
Stator
G3 ~
Rotor Control
AURORA WIND
131
LSWI-2.5MW
GENERAL SPECIFICATIONS
LSWI-2.5MW
132
AURORA WIND
Following the growing demand for wind power and the market trend to introduce higher power turbines using In Line Technology, the Power Converter Unit will be a real core component of the turbine permanent magnet generator system in the following years. OEMs need to reduce the installation cost per kWh and the trend of developing high specialized components manufactured to specification brought Power-One to introduce the new Large Wind 2.5MW inverter module. Power-Ones inverter module has been developed to meet the highest technology needs where the turbine interface the grid, having an innovative IGBTs based design that incorporates Power-Ones Industry Leading Technology for Renewable Energy Inverters. Key features include liquid cooling and Medium Voltage operation, in addition to an outstanding 98.7% conversion Efficiency result, are ideal for multi-MW Wind Power Generators off-shore and on-shore applications.
Features
Medium voltage of 5500 VDC lowers cabling costs Liquid cooling Industry-leading power density and higher reliability High conversion efficiency (98.7% at full load) Modular design permits flexibility in sizing multiple inverters Low output voltage harmonic distortion; allows higher power quality to the utility grid Power conversion state of the art technology 3-Level NPC topology IGBT Technology Vector control algorithm with active and reactive power regulation
WIND
AURORA WIND 133
With larger turbine unit sizes, medium-voltage converter systems are most suitable for the corresponding high power. Power-One inverter module is designed to answer this requirement and will help OEMs to reduce the size of the turbines and reduce the cost of the system itself.
Medium Voltage
The Power-One inverter is designed to work in parallel for larger Wind Turbines of 10MW and potentially above. Power-Ones inverter module is introducing a new concept of flexibility in this Power Converter environment industry and can be matched and completed with a passive or active rectification stage depending on the wind turbine OEMs needs.
The Power-One inverter module is specifically designed to meet the requirements coming from offshore and onshore applications and is equipped with an original designed Liquid Cooled system. The extremely-integrated design of the inverters (2mx2m) cabinet works very effectively in a marine environment by providing protection from water, oil, and gas. One of the most important benefits for a power converter located in a difficult offshore area is to ensure reliability while allowing for quick and easy maintenance. Power-Ones modularity design concept has been implemented in order to fulfill this critical task.
Block Diagram
Z9
Z5
Z1 C5 C6 C7
Z11 C2 D6 Z12 D4
Z7
Z3
Z8
D2
Z4
Voltage Sensor
DSP CONTROLLER
Voltage Sensor
134
AURORA WIND
PARAMETER
Input Nominal Input Range Max Transient DC Voltage Output Continuous rated power @ 50C AC Max Current rating Nominal AC Output Voltage AC Frequency Tolerance Nominal Power Factor (Cosphiac,r) AC Current Harmonics (THD%) Conversion Efficiency Peak Efficiency % (@ P nom) Environmental Environmental Protection Degree Operating Temperature Range General Data Local Communication Low Voltage Ride Through Cooling Weight Dimension (H x W x D) Safety Marking
LSWi-2.5MW
3300...4300 V 4300...5300 V
2.575 MW 725.0 A 2400 V 50Hz / 60Hz 3Hz > 0.995 (adj. 0.8) <3% with grid voltage (<2% Full Load)
98.7%
IP43 -30C...+50C
RS485 CANBUS Compliance with US & EU requirements Liquid Cooled. Required external Water pump and heat exchanger 3500kg / 7716lb 2100mm x 2522mm x 803mmx / 82.7 x 99.3 x 31.6
CE
AURORA WIND
135
MSWI-55.0 MSWI-110.0
GENERAL SPECIFICATIONS
MSWI-55.0 MSWI-110.0
NEW
136
AURORA WIND
These Aurora Medium Scale Wind Inverters are designed for community scale wind system. These scalable modular inverter system, based on 55kW conversion modules, increases usable power and improve availability. As per modular concept, in case of single module failure, the system is able to continue harvesting energy with a self exclusion of the faulty cluster. Industry-leading power conversion efficiencies of up to 96.3% optimize energy harvesting across a wide array of operating conditions. Inverter systems are delivered pre-configured and pre-tested in rugged enclosures.
Features
Reduced susceptibility to a single fault. In case of a component failure, a maximum of 55kW will be lost Reduced acoustic noise due to the high switching frequency Reverse-polarity protection minimizes potential damage caused by array mis-wiring Maximum input voltage up to 1000 Vdc Integrated DC and AC distribution and protection. Fully equipped for connection, additional accessories
WIND
not required Easy installation and maintenance procedure. Front extractible DC/AC converters and front accessibility to all critical parts High efficiencies deliver more energy Independent RS-485 communication interface for inverter power curve driving
AURORA WIND 137
OVR REVERSE POLARITY PROTECTION IN1 (+) EMC FILTER IN 1 (-) DC / AC INVERTER LINE FILTER EMI FILTER DC FUSE DC BREAKER INVERTER MODULE 55kW CONTACT AC FUSE
PE
CONTROL CIRCUIT
OVR REVERSE POLARITY PROTECTION IN 2 (+) EMC FILTER IN 2 (-) DC / AC INVERTER LINE FILTER EMI FILTER DC FUSE DC BREAKER INVERTER MODULE 55kW CONTACT AC FUSE
PE
CONTROL CIRCUIT
AC CONTACTOR
100kVA TRANSFORMER
PE
MSWI-55.0
100 99 98 97 Efficiency, % Efficiency, % 96 95 94 93 92 91 90 0% 10% 20% 30% 40% 50% 60% 70% 80% 90% 100% 330 Vdc 370 Vdc 480 Vdc 91 90 0% 10% 20% 30% 100 99 98 97 96 95 94 93 92
MSWI-110.0
330 Vdc 370 Vdc 480 Vdc 40% 50% 60% 70% 80% 90% 100%
138
AURORA WIND
PARAMETER
Input Side Absolute Maximum DC Input Voltage (Vmax,abs) Input DC Voltage Range (VDCmin,r ... VDCmax,r) Input DC Range (VDCmin,f ... VDCmax,f) at Full Power Number of Independent Modules Master/Slave Maximum Combined DC Input Current (Idcmaxc) Maximum DC Input Current for Each Module (Idcmax,m) Number of DC Inputs Pairs DC Connection Type Input Protection Reverse Polarity Protection Input Over Voltage Protection - Varistor Generator Isolation Control Output Side AC Grid Connection Type Rated AC Power (Pac,r) Rated Grid Voltage (Vac,r) AC Voltage Range (Vacmin...Vacmax) Maximum Output Current (Iac,max) Rated Frequency (fr) Frequency Range (fmin...fmax) Power Factor (Cosphiac,r) Total Harmonic Distortion AC Connection Type Output Protection Anti-Islanding Protection Output Overvoltage Protection (Varistor) Operating Performance Maximum Efficiency (max) Weithted Efficiency (EURO / CEC ) Stand-by Consumption AC Auxiliary Supply Auxiliary Supply Consumption Inverter Switching Frequency Communication Wired Local Monitoring Remote Monitoring User Interface Environmental Ambient Temperature Range Relative Humidity Noise Emission Maximum Operating Altitude without Derating Physical Environmental Protection Rating Cooling Required Air Cooling Flow Dimension (H x W x D) Weight Weight of the module Safety Transformer Marking Safety and EMC Standard Grid Standard
1. The AC voltage range may vary depending on specific country grid standard 2. The Frequency range may vary depending on specific country grid standard
MSWI-55.0
1000 V 475...950 V 475...850 V 1 124 A 124 A 1 Cable lug No 2 for each input pair, Class II According to local standard Three phase ( / ) 55 kW 400 V 320...480 V (1) 81 A 50 / 60 Hz 47...53 / 57...63 Hz (2) > 0.995 < 3% (@Pac,r) 1 x 95 mm2 (M8) According to local standard Yes, Class II 93.30% 95.1% / 96.0% < 17 W 3x400 Vac +N, 50/60 Hz < 0.36% of Pac,r 18 kHz
MSWI-110.0
1000 V 475...950 V 475...850 V 2 248 A 124 A 2
110 kW
160 A
PVI-USB-RS485_232 (opt.) PVI-AEC-EVO (opt.), AURORA-UNIVERSAL (opt.) 16 characters x 2 lines LCD display for each module -10...+ 60C/+14...140F con derating sopra 50C/122F 0...95% non condensing < 62 dB(A) @ 1m < 65 dB(A) @ 1m 1000 m / 3280 ft IP 20 Air Forced 1600 m3/h - 944 CFM 2800 m3/h - 1652 CFM 1675mm x 1250mm x 850mm / 65.9 x 49.2 x 33.5 <700 kg / 1543 lb <800 kg / 1765 lb <60 kg / 132 lb Yes CE EN 50178, EN61000-6-2, EN61000-6-4, EN61000-3-11, EN61000-3-12 Guideline ENEL, G59
AURORA WIND
139
MSWI-50-US MSWI-100-US
GENERAL SPECIFICATIONS
MSWI-50-US-208 MSWI-50-US-480 MSWI-100-US-208 MSWI-100-US-480
140
AURORA WIND
These Aurora Medium Scale Wind Inverters are designed for community scale wind system. These scalable modular inverter system, based on 50kW conversion modules, increases usable power and improve availability. As per modular concept, in case of single module failure, the system is able to continue harvesting energy with a self exclusion of the faulty cluster. Industry-leading power conversion efficiencies of up to 95.8% optimize energy harvesting across a wide array of operating conditions. Inverter systems are delivered pre-configured and pre-tested in rugged enclosures.
Features
Reduced susceptibility to a single fault. In case of a component failure, a maximum of 50kW will be lost Reduced acoustic noise due to the high switching frequency Reverse-polarity protection minimizes potential damage caused by array mis-wiring Maximum input voltage up to 600 Vdc Integrated DC and AC distribution and protection. Fully equipped for connection, additional accessories
WIND
AURORA WIND 141
not required Easy installation and maintenance procedure. Front extractible DC/AC converters and front accessibility to all critical parts High efficiencies deliver more energy Independent RS-485 communication interface for inverter power curve driving
OVR REVERSE POLARITY PROTECTION IN1 (+) EMC FILTER IN 1 (-) DC / AC INVERTER LINE FILTER EMI FILTER DC FUSE DC BREAKER INVERTER MODULE 50kW CONTACT AC FUSE
PE
CONTROL CIRCUIT
OVR REVERSE POLARITY PROTECTION IN 2 (+) EMC FILTER IN 2 (-) DC / AC INVERTER LINE FILTER EMI FILTER DC FUSE DC BREAKER INVERTER MODULE 50kW CONTACT AC FUSE
PE
CONTROL CIRCUIT
AC CONTACTOR
100kVA TRANSFORMER
PE
MSWI-50-US
100 99 98 97 Efficiency, % Efficiency, % 96 95 94 93 92 91 90 0% 10% 20% 30% 40% 50% 60% 70% 80% 90% 100% 330 Vdc 370 Vdc 480 Vdc 91 90 0% 10% 20% 30% 100 99 98 97 96 95 94 93 92
MSWI-100-US
330 Vdc 370 Vdc 480 Vdc 40% 50% 60% 70% 80% 90% 100%
142
AURORA WIND
PARAMETER
MSWI-50US-208
MSWI-50US-480
MSWI-100US-208
MSWI-100US-480
Input Side Absolute Maximum DC Input Voltage (Vmax,abs) 600 V 600 V Input DC Voltage Range (VDCmin,r ... VDCmax,r) 330...600 V 330...600 V Input DC Range (VDCmin,f ... VDCmax,f) at Full Power 330...600 V 330...600 V Number of Independent Modules Master/Slave 1 1 Maximum Combined DC Input Current (Idcmaxc) 170 A 340 A Maximum DC Input Current for Each Module (Idcmax,m) 170 A 170 A Number of DC Inputs Pairs 1 2 DC Connection Type Cable lug M10/M12 Cable lug Input Protection Reverse Polarity Protection No No Input Over Voltage Protection - Varistor Yes Yes Generator Isolation Control Yes Yes Output Side AC Grid Connection Type Three phase () Three phase () Rated AC Power (Pac,r) 50 kW 100 kW Rated Grid Voltage (Vac,r) 208 V 480 V 208 V 480 V AC Voltage Range (Vacmin...Vacmax) 183...228 V 422...528 V 183...228 V 422...528 V Maximum Output Current (Iac,max) 139 A 61 A 278 A 121 A Rated Frequency (fr) 60 Hz 60 Hz Frequency Range (fmin...fmax) 59.3...60.5 Hz 59.3...60.5 Hz Power Factor (Cosphiac,r) > 0.995 > 0.995 Total Harmonic Distortion < 4% (@Pac,r) < 4% (@Pac,r) AC Connection Type 3 x 2/0 AWG 90 / M10 3 x 2/0 AWG 90 / M10 Output Protection Anti-Islanding Protection According to UL 1741/IEE1547 According to UL 1741/IEE1547 Output Overvoltage Protection (Varistor) Yes Yes Operating Performance Maximum Efficiency (max) 95.6% 95.8% 95.6% 95.8% Weithted Efficiency (EURO / CEC ) - / 95.0% - / 95.0% Stand-by Consumption < 15 W < 30 W AC Auxiliary Supply 3 x 480 Vac, 50/60 Hz 3 x 480 Vac, 50/60 Hz Auxiliary Supply Consumption < 0.40% of Pac,r < 0.40% of Pac,r Inverter Switching Frequency 18 kHz 18 kHz Communication Wired Local Monitoring PVI-USB-RS485_232 (opt.) PVI-USB-RS485_232 (opt.) Remote Monitoring PVI-AEC-EVO (opt.), AURORA-UNIVERSAL (opt.) PVI-AEC-EVO (opt.), AURORA-UNIVERSAL (opt.) User Interface Environmental Ambient Temperature Range Relative Humidity Noise Emission Maximum Operating Altitude without Derating Physical Environmental Protection Rating Cooling Required Air Cooling Flow Dimension (H x W x D) Weight Weight of the module Safety Transformer Marking Safety and EMC Standard Grid Standard -10...+ 50C/+14...122F with derating above 40C/104F 0...95% non condensing < 62 dB(A) @ 1m 1000 m / 3280 ft IP 20 / NEMA 1 Air Forced 1500 m3/h - 885 CFM 1275mm x 1675mm x 850mm / 50.2 x 66 x 33.5 700 kg / 1543 lb <70 kg / 154 lb Yes cCSAus UL 1741, CSA - C22.2 N. 107.1-01 IEEE 1547 -10...+ 50C/+14...122F with derating above 40C/104F 0...95% non condensing < 62 dB(A) @ 1m 1000 m / 3280 ft IP 20 / NEMA 1 Air Forced 2000 m3/h - 1180 CFM 1275mm x 1675mm x 850mm / 50.2 x 66 x 33.5 850 kg / 1873 lb <70 kg / 154 lb Yes cCSAus UL 1741, CSA - C22.2 N. 107.1-01 IEEE 1547 16 characters x 2 lines LCD display for each module 16 characters x 2 lines LCD display for each module
AURORA WIND
143
NEW
144
AURORA WIND
This new product added to Power-Ones Aurora wind accessories offers more flexibility for small wind applications. The 25 kW Wind Interface is designed to be a smart rectifier which once programmed with the turbines power curve it can control the output of single or multiple inverters allowing scalability for installation. Additionally it provides over-voltage protection and drives both a diversion load and a dumpload braking system.
Features
Conversion efficiency at rating: 99.6% Three-Phase input from PMG Unfused path to breake load Automatic diversion load function proportionally introduced on an external dedicated output Adjustable breake and diversion load intervention thresholds Fused wind input to inverter Automatic brake function above 530 Vdc Activation function of external brake resistor Power curve owner Working frequency skip window (optional)
WIND
AURORA WIND 145
BR K2 (+)
CONTROL
GP 2 N.C N.O C GP 3 N.C N.O C CAN BUS EXT CAN BUS INT RS485 EXT RS485 INT
CANH
FC 1 REF 1
FC 2 REF 2
FC 3 REF 3
FC 4 REF 4
CANH
CANL
CANL
+ T/R
+ T/R
GND
GND
GND
PARKING RESISTOR
(RECOMMENDED)
PMG
BR K2 (+)
BR K2 (-)
BR K1 (+) BR K1 (-)
1 2 3
WIND INTERFACE
FREQ CMD
WIND INVERTER
L
GND
- T/R
- T/R
GRID
IN (+) IN (-) N
FC 1 MAIN RELAY REF 1 FC 2 REF 2 FC 3 REF 3 FC 4 REF 4 OUT 1.1(+) OUT 1.2(+) OUT 1.3(+) OUT 1.4(+) OUT 2.1 (-) OUT 2.2 (-) OUT 2.3 (-) OUT 2.4 (-)
ES
HF TRANSFORMER
WIND INVERTER
L IN (+) IN (-) FCX (+)/WT (+) REF (-)/WT (-) N
146
AURORA WIND
PARAMETER
Input Side AC Input Range (No damage) (Vacd,min...Vacd,max) Operating AC Input Range (Vacmin...Vacmax) Operating Frequency Range (fmin...fmax) Maximum AC Input Current (Idcmax) Maximum Current in Main Brake Resistor (IMBR,max) Voltage Range in Main Brake Resistor (VMBRmin...VMBRmax) Maximum Current in Auxiliary Brake Resistor (IABR,max) DC Voltage Range in Auxiliary Brake Resistor (VABRmin...VABRmac) Type of Inputs Connection Input protection Input Over Voltage Portection - Varistor Input Fuse Size Output Side Maximum Output Power (Pdcmax) Output Voltage Range (Vdc,min...Vdc,max) Maximum Output Current (Idc,max) Type of Output Connection Output Protection Output Over Voltage Operating Performance Peak Efficiency (peak) Stand-by Consumption Communication Local Monitoring System Remote Control User Interface Environmental Ambient Temperature Range Relative Humidity Noise Emission Maximum Operating Altitude without Derating Physical Environmental Protection Rating Cooling Dimension (H x W x D) Weight Mounting System Safety Marking Safety and EMC standard
25kW-WIND-INTERFACE
25kW-WIND-INTERFACE-US
0...600 V 35...600 V 0...600 Hz (1) 85.0 A 50.0 A 0...750 V 30.0 A 0...1000 V Screw terminal block Cable Gland 4 3 x 100.0 A 25.0 kW 50...850 V 80.0 A Screw terminal block Cable Gland Yes 99.6 % <6W RS 485, 1 CAN BUS for parallelling operation AURORA DESKTOP (opt.) 16 characters x 2 line LCD display -25...+55C / -13...131F < 100% Condensing < 40 dB(A) 2000 m / 6560 ft IP 65 Natural 650mm x 350mm x 265mm / 25 x 12.8 x 9 22 kg / 48.5 lb Wall Bracket CE EN 51178, EN 61000-6-2, EN 61000-6-4
0...400 V 35...400 V 0...600 Hz (1) 85.0 A 50.0 A 0...600 V 30.0 A 0...600 V Screw terminal block Knock Out 3/8, 3/4, 1/2 4 3 x 100.0 A 25.0 kW 50...600 V 100.0 A Screw terminal block Knock Out 3/8, 3/4, 1/2 Yes 99.6 % <6W RS 485, 1 CAN BUS for parallelling operation AURORA DESKTOP (opt.) 16 characters x 2 line LCD display -25...+55C / -13...131F < 100% Condensing < 40 dB(A) 2000 m / 6560 ft NEMA 4X Natural 650mm x 350mm x 265mm / 25 x 12.8 x 9 22 kg / 48.5 lb Wall Bracket cCSAus UL 1741, CSA - C22.2 N. 107.1-01
1.The frequency input is for single isolated driving source. When using wind tach, the available frequency range is 5...200Hz. The inverter also provides a +5V internal pull up max. 0.5mA.
AURORA WIND
147
PVI-12.5-TL-W
GENERAL SPECIFICATIONS
PVI-12.5-TL-OUTD-W
NEW
148
AURORA WIND
This Aurora grid-tie wind inverter offers a unique combination of high efficiencies, installerfriendly designs and long service life. A major selling point of the Aurora Wind inverter is its very wide input voltage range ensuring power is continuously harvested from the lightest breeze to the strongest wind for small wind applications for up to 50kW. The competitive initial acquisition costs matched with the high efficiencies of up to 97.7% wide input range significantly increase return on investment on wind-power installations. This compact, weather-sealed inverter has a 16-point profile to best match the power curve of each wind turbine. Wind Interface box is an optional accessory.
Features
Electrolyte-free power converter to further increase the life expectancy and long term reliability True Three-Phase bridge topology for DC/AC output converter Transformerless operation for highest efficiency Power curve customization with high granularity to reach high level of power production yield Outdoor enclosure for unrestricted use under any environmental conditions Compact size and high power density Optimized real time power curve tracking algorithm and improved energy harvesting High overload capability: works up the power max limits under most ambient conditions Compatible with 25kW Wind Interface
WIND
AURORA WIND 149
IN1.1(+) IN1.2(+)
BOOST 1 (DC/DC)
BULK CAPS
INVERTER (DC/AC)
IN1.1(-) IN1.2(-)
LINE FILTER
IN1.1(+) IN1.2(+)
BOOST 2 (DC/DC)
PE
IN1.1(-) IN1.2(-)
RS485 + T/R - T/R RTN DC/DC DSP CONTR. DC/AC DSP CONTR. REMOTE CONTROL +R -R WT (+) WT (-) WIND SPEED INPUT
CONTROL CIRCUIT
PVI-12.5-TL-OUTD-W
100 99 98 97
Efficiency, %
96 95 94 93 92 91 90 0% 10%
360 Vdc 580 Vdc 750 Vdc 20% 30% 40% 50% 60% 70% 80% 90% 100%
150
AURORA WIND
PARAMETER
Input Side Maximum Absolute DC Input Voltage V(dc,abs) Operating DC Input Range (Vdcmin...Vdcmax) DC Input range at full power (Vfp,min...Vfp,max) Dc Power Limitation Maximum DC Input Current (Idcmax) Maximum Input Short Circuit Current DC Connection Type Input Protection Reverse Polarity Protection Input Over Voltage Protection - Varistor Generator Isolation Control Output Side AC Grid Connection Rated AC Power (Pacr) Maximum AC Output Power (Pacmax) Rated Grid AC Voltage (Vac,r) AC Voltage Range Maximum Output AC Current (Iac,max) Rated Frequency (fr) Frequency Range (fmin...fmax) Nominal Power Factor (Cosphiac,r) Total Harmonic Distortion AC Connection Type Output Protection Anti-islanding protection Maximum AC Overcurrent Protection Output Over Voltage Protection - Varistor Operating Performance Maximum Efficiency (max) Stand-by Consumption Communication Wired Local Monitoring Remote Monitoring Wireless Local Monitoring User Interface Environmental Ambient Temperature Range Noise Emission Maximum Operating Altitude with Derating Physical Environmental Protection Rating Cooling Dimension (H x W x D) Weight Safety Isolation Level Marking Safety and EMC standard Grid Standard Available Products Variants Standard
1. The AC voltage range may vary depending on specific country grid standard 2. The Frequency range may vary depending on specific country grid standard
PVI-12.5-TL-OUTD-W
900 V 100...850 V 360...750 V Power Limit to 10 A max for Vdc200 V Linear Derating From MAX to Null [750VVdc850V] 36 A 44 A Screw Terminal Block, Cable Glands No 4 Yes Three Phase (/Y) 12500 W 13800 W 400 V 320...480 V (1) 20 A 50 Hz 47...53 Hz (2) > 0.995 < 2% Screw Terminal Block, Cable Glands According to local standard 22 A 3, star connected to common point plus gas arrester to ground 97.7% < 10 W PVI-USB-RS485_223 (opt.), PVI-DESKTOP (opt.) PVI-AEC-EVO (opt.), AURORA-UNIVERSAL (opt.) PVI-DESKTOP (opt.) with PVI-RADIOMODULE (opt.) 16 characters x 2 lines LCD display -20...+60C /-4...140F with derating above 50C/122F < 50 dB(A) 2000 m / 6560 ft IP 65 Natural 716mm x 645mm x 222mm / 28.2 x 25.4 x 8.7 38 kg / 83.8 lb Transformerless CE EN 50178, AS/NZS3100, AS/NZS 60950, EN61000-6-2, EN61000-6-4, EN61000-3-11, EN61000-3-12 Guideline ENEL, VDE 0126-1-1, AS4777, G59/2 PVI-12.5-TL-OUTD-W
AURORA WIND
151
SSWI-10.0-I
GENERAL SPECIFICATIONS
SSWI-10.0-I-OUTD SSWI-10.0-I-OUTD-US-208 SSWI-10.0-I-OUTD-US-480
NEW
152
AURORA WIND
This Aurora grid-tie wind inverter offers a unique combination of high efficiencies, installerfriendly designs and long service life. A major selling point of the Aurora Wind inverter is its very wide input voltage range ensuring power is continuously harvested from the lightest breeze to the strongest wind. This high-frequency isolated three-phase unit allows for a direct parallel connection of multiple units, allowing for small wind applications for up to 50kW. The competitive initial acquisition costs matched with the high efficiencies of up to 97.1% wide input range significantly increase return on investment on wind-power installations. This compact, weather-sealed inverter has a 16-point profile to best match the power curve of each wind turbine. Wind Interface box is an optional accessory.
Features
Electrolyte-free power converter to further increase the life expectancy and long term reliability True Three-Phase bridge topology for DC/AC output converter Galvanic isolation by high frequency transformer Power curve customization with high granularity to reach high level of power production yield Outdoor enclosure for unrestricted use under any environmental conditions Compact size and high power density Optimized real time power curve tracking algorithm and improved energy harvesting High overload capability: works up the power max limits under most ambient conditions Compatible with 25kW Wind Interface Each inverter is set on specific grid codes which can be selected in the field
WIND
AURORA WIND 153
IN1.1(+) IN1.2(+)
BOOST 1 (DC/DC)
HF TRANSFORMER
BULK CAPS
INVERTER (DC/AC)
IN1.1(-) IN1.2(-)
LINE FILTER
IN1.1(+) IN1.2(+)
BOOST 2 (DC/DC)
HF TRANSFORMER
PE
IN1.1(-) IN1.2(-)
RS485 + T/R - T/R RTN DC/DC DSP CONTR. DC/AC DSP CONTR. REMOTE CONTROL +R -R WT (+) WT (-) WIND SPEED INPUT OPTO ISOLATOR
CONTROL CIRCUIT
SSWI-10.0-I-OUTD
100 99 98 97
Efficiency, %
96 95 94 93 92 91 90 0% 10%
416 Vdc
20%
30%
40%
50%
60%
70%
80%
90%
100%
154
AURORA WIND
PARAMETER
Input Side Maximum Absolute DC Input Voltage V(dc,abs) Operating DC Input Range (Vdcmin...Vdcmax) DC Input range at full power (Vfp,min...Vfp,max) Dc Power Limitation Maximum DC Input Current (Idcmax) Maximum Input Short Circuit Current DC Connection Type Input Protection Reverse Polarity Protection Input Over Voltage Protection - Varistor Generator Isolation Control Output Side AC Grid Connection Rated AC Power (Pacr) Maximum AC Output Power (Pacmax) Rated Grid AC Voltage (Vac,r) AC Voltage Range Maximum Output AC Current (Iac,max) Rated Frequency (fr) Frequency Range (fmin...fmax) Nominal Power Factor (Cosphiac,r) Total Harmonic Distortion AC Connection Type Output Protection Anti-islanding protection Maximum AC Overcurrent Protection Output Over Voltage Protection - Varistor Operating Performance Maximum Efficiency (max) Stand-by Consumption Communication Wired Local Monitoring Remote Monitoring Wireless Local Monitoring User Interface Environmental Ambient Temperature Range Noise Emission Maximum Operating Altitude with Derating Physical Environmental Protection Rating Cooling Dimension (H x W x D) Weight Safety Isolation Level Marking Safety and EMC standard Grid Standard Available Products Variants Standard
SSWI-10.0-I-OUTD-400
520 V 120...520 V 220...470 V Linear Derating From MAX to Null [470VVdc520V] 48 A 58 A Screw Terminal Block Cable Glands No 4 Yes Three Phase (/Y) 10000 W 11000 W 400 V 320...480 V (1) 16 A 50 Hz 47...53 Hz (2) > 0.995 < 2% Screw Terminal Block Cable glands According to local standard 20 A 3, star connected to common point plus gas arrester to ground 97.1% < 8W PVI-USB-RS485_223 (opt.), PVI-DESKTOP (opt.) PVI-AEC-EVO (opt.), AURORA-UNIVERSAL (opt.) PVI-DESKTOP (opt.) with PVI-RADIOMODULE (opt.) 16 characters x 2 lines LCD display -25...+60C /-13...140F with derating above 45C/113F < 50 dB(A) 2000 m / 6560 ft IP 65 Natural 716 mm x 645mm x 222 mm / 28.2 x 25.4 x 8.7 44.9 kg / 99 lb HF Transformer CE EN 50178, AS/NZS3100, AS/NZS 60950, EN610006-2, EN61000-6-4, EN61000-3-11, EN61000-3-12 Guideline ENEL, VDE 0126-1-1, AS4777, G59/2, EN 50438 SSWI-10.0-I-OUTD-400
60 Hz 59.3...60.5 Hz > 0.995 < 2% Screw Terminal Block 3 Knock-Outs: or 1 (w/ring reducer) According to UL 1741/IEE1547 35 A 20 A 3, star connected to common point plus gas arrester to ground 96.7% < 8W PVI-USB-RS485_223 (opt.), PVI-DESKTOP (opt.) PVI-AEC-EVO (opt.), AURORA-UNIVERSAL (opt.) PVI-DESKTOP (opt.) with PVI-RADIOMODULE (opt.) 16 characters x 2 lines LCD display -25...+60C /-13...140F with derating above 45C/113F < 50 dB(A) 2000 m / 6560 ft NEMA 4X Natural 716 mm x 645mm x 222 mm / 28.2 x 25.4 x 8.7 44.9 kg / 99 lb HF Transformer cCSAus UL 1741, CSA - C22.2 N. 107.1-01 IEEE 1547 SSWI-10.0-I-OUTD-US-208 SSWI-10.0-I-OUTD-US-480 97.1%
1. The AC voltage range may vary depending on specific country grid standard 2. The Frequency range may vary depending on specific country grid standard 3. Just for -480 version, the inverter applies current limit derating below 220V down to 2A/1A at 90V
AURORA WIND
155
156
AURORA WIND
Power-Ones Aurora Wind Interface box is a key accessory within the small wind applications. The compact wind interface is designed to work in tandem with a small wind inverter for a grid-connected application. Offering 99.4% efficiency, the Wind Interface Box passively rectifies the current produced by the turbine generator to feed the wind inverter. Additionally it drives a dumpload braking system.
Features
Conversion efficiency at rating: 99.4% Fused wind input to inverter Automatic brake function above 530 Vdc Activation function of external brake resistor Passive Three-Phase rectification
WIND
AURORA WIND 157
BULK CAPS
OUT 1.1(+) OUT 1.2(+) OUT 1.3(+) OUT 1.4(+) OUT 2.1(-) OUT 2.2(-) OUT 2.3(-) OUT 2.4(-)
TO WIND INVERTER
GND
DIVERSION LOAD SWITCH BRAKE (+) CONTROL TO DIVERSION LOAD BRAKE (-)
Block Diagram
FREQUENCY SIGNAL (OPTIONAL)
GRID
RS485
30 mA
USB
HOUSE
158 AURORA WIND
PARAMETER
Input Side AC Input Range (No damage) (Vacd,min...Vacd,max) Operating AC Input Range (Vacmin...Vacmax) Operating Frequency Range (fmin...fmax) Maximum AC Input Current (Idcmax) Maximum Current in Main Brake Resistor (IMBR,max) Voltage Range in Main Brake Resistor (VMBRmin...VMBRmax) Type of Inputs Connection Input protection Input Over Voltage Portection - Varistor Input Fuse Size Output Side Maximum Output Power (Pdcmax) Output Voltage Range (Vdc,min...Vdc,max) Maximum Output Current (Idc,max) Type of Output Connection Output Protection Output Over Voltage Operating Performance Peak Efficiency (peak) Stand-by Consumption Communication Local Monitoring System Remote Control User Interface Environmental Ambient Temperature Range Relative Humidity Noise Emission Maximum Operating Altitude without Derating Physical Environmental Protection Rating Cooling Dimension (H x W x D) Weight Mounting System Safety Marking Safety and EMC standard
252 mm x 287 mm x 85.7 252 mm x 287 mm x 85.7 252 mm x 287 mm x 85.7 252 mm x 287 mm x 85.7 mm / 9.9 x 11.3 x 3.37 mm / 9.9 x 11.3 x 3.37 mm / 9.9 x 11.3 x 3.37 mm / 9.9 x 11.3 x 3.37 1.8 kg / 4.0 lb Wall Bracket CE EN 50178, EN 61000-6-2, EN 61000-6-4 1.8 kg / 4.0 lb Wall Bracket CE EN 50178, EN 61000-6-2, EN 61000-6-4 1.8 kg / 4.0 lb Wall Bracket cCSAus UL 1741, CSA - C22.2 N. 107.1-01 1.8 kg / 4.0 lb Wall Bracket cCSAus UL 1741, CSA - C22.2 N. 107.1-01
1.The frequency input is for single isolated driving source. When using wind tach, the available frequency range is 5...200Hz. The inverter also provides a +5V internal pull up max. 0.5mA.
AURORA WIND
159
PVI-5000-TL-W PVI-6000-TL-W
GENERAL SPECIFICATIONS
PVI-5000-TL-OUTD-W PVI-6000-TL-OUTD-W PVI-5000-OUTD-US-W PVI-6000-OUTD-US-W
160
AURORA WIND
Aurora grid-tie transformerless wind inverters offer a unique combination of high efficiencies, installer-friendly designs and long service life. A major selling point of the Aurora Wind inverter is its very wide input voltage range ensuring power is continuously harvested from the lightest breeze to the strongest wind. The competitive initial acquisition costs matched with the high efficiencies of up to 97.0% significantly increase return on investment on wind-power installations. This compact, weather-sealed inverter has a 16-point profile to best match the power curve of each wind turbine.
Features
Single Phase Output Transformerless operation for highest efficiency Power curve customization with high granularity to reach high level of power production yield Outdoor enclosure for unrestricted use under any environmental conditions Compact size and high power density Optimized real time power curve tracking algorithm and improved energy harvesting High overload capability: works up the power max limits under most ambient conditions Compatible with 25kW Wind Interface Compatible with 7200 Wind Interface
WIND
AURORA WIND 161
IN1.1(+) IN1.2(+)
BOOST 1 (DC/DC)
BULK CAPS
INVERTER (DC/AC)
IN1.1(-) IN1.2(-)
LINE FILTER
L3
IN1.1(+) IN1.2(+)
BOOST 2 (DC/DC)
PE
IN1.1(-) IN1.2(-)
RS485 + T/R - T/R RTN DC/DC DSP CONTR. DC/AC DSP CONTR. REMOTE CONTROL +R -R WT (+) WT (-) WIND SPEED INPUT
CONTROL CIRCUIT
PVI-6000-OUTD-US-W
100 99 98 97
Efficiency, %
96 95 94 93 92 91 90 0% 10% 20% 30% 40% 50% 60% 70% 80% 90% 100% % of Rated Output Power
250 Vdc 400 Vdc 480 Vdc
162
AURORA WIND
PARAMETER
Input Side Maximum Absolute DC Input Voltage V(dc,abs) Operating DC Input Range (Vdcmin...Vdcmax) DC Input range at full power (Vfp,min...Vfp,max) Dc Power Limitation Maximum DC Input Current (Idcmax) Maximum Input Short Circuit Current DC Connection Type Input Protection Reverse Polarity Protection Input Over Voltage Protection - Varistor Generator Isolation Control Output Side AC Grid Connection Rated AC Power (Pacr) Maximum AC Output Power (Pacmax) Rated Grid AC Voltage (Vac,r) AC Voltage Range Maximum Output AC Current (Iac,max) Rated Frequency (fr) Frequency Range (fmin...fmax) Nominal Power Factor (Cosphiac,r) Total Harmonic Distortion AC Connection Type Output Protection Anti-islanding protection Maximum AC Overcurrent Protection Output Over Voltage Protection - Varistor Operating Performance Maximum Efficiency (max) Stand-by Consumption Communication Wired Local Monitoring Remote Monitoring Wireless Local Monitoring User Interface Environmental Ambient Temperature Range Noise Emission Maximum Operating Altitude with Derating Physical Environmental Protection Rating Cooling Dimension (H x W x D) Weight Safety Isolation Level Marking Safety and EMC standard Grid Standard Available Products Variants Standard
1. The AC voltage range may vary depending on specific country grid standard 2. The Frequency range may vary depending on specific country grid standard 3. Limited to 4600 W for Germany 4. Add suffix -AU to product description
PVI-5000-TL-OUTD-W
600 V 50...580 V 150...530 V Linear Derating From MAX to Null [530VVdc580V] 36 A 44 A Screw Terminal Block Cable Glands No 4 Yes Single Phase 5000 W(3) 5000 W 230 V 180...264 V (1) 25 A 50 Hz 47...53 Hz (2) > 0.995 < 2% Screw Terminal Block Cable Glands According to local standard 32 A 2 (L-N/L-PE) 97.0% < 8W PVI-USB-RS485_223 (opt.), PVI-DESKTOP (opt.) PVI-AEC-EVO (opt.), AURORA-UNIVERSAL (opt.) PVI-DESKTOP (opt.) with PVI-RADIOMODULE (opt.) 16 characters x 2 lines LCD display
PVI-6000-TL-OUTD-W
600 V 50...580 V 180...530 V Linear Derating From MAX to Null [530VVdc580V] 36 A 44 A Screw Terminal Block Cable Glands No 4 Yes Single Phase 6000 W 6000 W 230 V 180...264 V (1) 30 A 50 Hz 47...53 Hz (2) > 0.995 < 2% Screw Terminal Block Cable Glands According to local standard 40 A 2 (L-N/L-PE) 97.0% < 8W PVI-USB-RS485_223 (opt.), PVI-DESKTOP (opt.) PVI-AEC-EVO (opt.), AURORA-UNIVERSAL (opt.) PVI-DESKTOP (opt.) with PVI-RADIOMODULE (opt.) 16 characters x 2 lines LCD display
-25...+ 60C /-13...140F with derating above 50C/122F -25...+ 60C /-13...140F with derating above 50C/122F < 50 dB(A) < 50 dB(A) 2000 m / 6560 ft 2000 m / 6560 ft IP 65 Natural 810mm x 325mm x 228mm / 31.9 x 12.8 x 8.7 27 kg / 59.5 lb Transformerless CE EN 50178, EN61000-6-2, EN61000-6-4, EN61000-3-11, EN61000-3-12 VDE 0126-1-1, G59/2, EN 50438 PVI-5000-TL-OUTD-W IP 65 Natural 810mm x 325mm x 228mm / 31.9 x 12.8 x 8.7 27 kg / 59.5 lb Transformerless CE EN 50178, EN61000-6-2, EN61000-6-4, EN61000-3-11, EN61000-3-12 DK 5940, VDE 0126-1-1, G59/2, EN 50438, RD1663, AS4777(4) PVI-6000-TL-OUTD-W
AURORA WIND
163
IN1.1(+) IN1.2(+)
BOOST 1 (DC/DC)
BULK CAPS
INVERTER (DC/AC)
IN1.1(-) IN1.2(-)
LINE FILTER
L3
IN1.1(+) IN1.2(+)
BOOST 2 (DC/DC)
PE
IN1.1(-) IN1.2(-)
RS485 + T/R - T/R RTN DC/DC DSP CONTR. DC/AC DSP CONTR. REMOTE CONTROL +R -R WT (+) WT (-) WIND SPEED INPUT
CONTROL CIRCUIT
PVI-6000-OUTD-US-W
100 99 98 97
Efficiency, %
96 95 94 93 92 91 90 0% 10% 20% 30% 40% 50% 60% 70% 80% 90% 100% % of Rated Output Power
250 Vdc 400 Vdc 480 Vdc
164
AURORA WIND
PARAMETER
Input Side Maximum Absolute DC Input Voltage V(dc,abs) Operating DC Input Range (Vdcmin...Vdcmax) DC Input range at full power (Vfp,min...Vfp,max) Dc Power Limitation Maximum DC Input Current (Idcmax) Maximum Input Short Circuit Current DC Connection Type Input Protection Reverse Polarity Protection Input Over Voltage Protection - Varistor Generator Isolation Control Output Side AC Grid Connection Rated AC Power (Pacr) Maximum AC Output Power (Pacmax) Rated Grid AC Voltage (Vac,r) AC Voltage Range Maximum Output AC Current (Iac,max) Rated Frequency (fr) Frequency Range (fmin...fmax) Nominal Power Factor (Cosphiac,r) Total Harmonic Distortion AC Connection Type Output Protection Anti-islanding protection Maximum AC Overcurrent Protection Output Over Voltage Protection - Varistor Operating Performance Maximum Efficiency (max) Stand-by Consumption Communication Wired Local Monitoring Remote Monitoring Wireless Local Monitoring User Interface Environmental Ambient Temperature Range Noise Emission Maximum Operating Altitude with Derating Physical Environmental Protection Rating Cooling Dimension (H x W x D) Weight Safety Isolation Level Marking Safety and EMC standard Grid Standard Available Products Variants Standard 208 40 A
PVI-6000-OUTD-US-W
600 V 50...580 V 180...530 V Linear Derating From MAX to Null [530VVdc580V] 36 A 44 A Screw Terminal Block 3 Knock-Outs: 1 or 1 (w/ Ring Red.) No 4 Yes 240 Single Phase / Split Phase 6000 W 6000 W 240 V 211...264 V 28 A 60 Hz 59.3...60.5 Hz > 0.995 < 2% Screw Terminal Block 3 Knock-Outs: 1 or 1 (w/ring reducer) Wire Size: Max. AWG8 240 According to UL 1741/IEE1547 35 A 2 (L-N/L-PE) 97.0% < 8W PVI-USB-RS485_223 (opt.), PVI-DESKTOP (opt.) PVI-AEC-EVO (opt.), AURORA-UNIVERSAL (opt.) PVI-DESKTOP (opt.) with PVI-RADIOMODULE (opt.) 16 characters x 2 lines LCD display -25...+ 60C /-13...140F with derating above 50C/122F < 50 dB(A) 2000 m / 6560 ft NEMA 4X Natural 810mm x 325mm x 228mm / 31.9 x 12.8 x 8.7 26.3 kg / 58 lb Transformerless cCSAus UL 1741, CSA - C22.2 N. 107.1-01 IEEE 1547 PVI-6000-OUTD-US-W 277 30 A
208
277
208 V 183...228 V 30 A
277 V 244...304 V 24 A
AURORA WIND
165
SSWI-3.8-I SSWI-4.6-I
GENERAL SPECIFICATIONS
SSWI-3.8-I-OUTD SSWI-4.6-I-OUTD SSWI-3.8-I-OUTD-US SSWI-4.6-I-OUTD-US
NEW
166
AURORA WIND
This isolated inverter is optimized for use in small wind. applications. This inverter has also been designed to serve all countries and regions with specific field-configurable set-ups available for all major country grid codes and display languages. The competitive initial acquisition costs matched with the high efficiencies of up to 96.9% wide input range significantly increase return on investment on wind-power installations.
Its high frequency isolated topology allows this unit to be lightweight and compact in size to help with transportation and installation. This rugged outdoor inverter has been designed as a completely sealed unit to withstand the harshest environmental conditions.
Features
Single Phase Output Galvanic isolation by high frequency transformer Power curve customization with high granularity to reach high level of power production yield Outdoor enclosure for unrestricted use under any environmental conditions Compact size and high power density Optimized real time power curve tracking algorithm and improved energy harvesting High overload capability: works up the power max limits under most ambient conditions Each inverter is set on specific grid codes which can be selected in the field Compatible with 25kW Wind Interface Compatible with 7200 Wind Interface
WIND
AURORA WIND 167
IN1.1(+) IN1.2(+)
BOOST 1 (DC/DC)
HF TRANSFORMER
BULK CAPS
INVERTER (DC/AC)
IN1.1(-) IN1.2(-)
LINE FILTER
IN1.1(+) IN1.2(+)
BOOST 2 (DC/DC)
HF TRANSFORMER
PE
IN1.1(-) IN1.2(-)
RS485 + T/R - T/R RTN DC/DC DSP CONTR. DC/AC DSP CONTR. REMOTE CONTROL +R -R WT (+) WT (-) WIND SPEED INPUT OPTO ISOLATOR
CONTROL CIRCUIT
SSWI-3.8-OUTD-US-W
SSWI-4.6-OUTD-US-W
100 99 98 97 96 Efficiency, % 95 94 93 92 91 90 0% 10% 20% 30% 40% 50% 60% 70% 80% 90% 100% 200 Vdc 340 Vdc 416 Vdc 200 Vdc 340 Vdc 416 Vdc Efficiency, %
100 99 98 97 96 95 94 93 92 91 90 0% 10% 20% 30% 40% 50% 60% 70% 80% 90% 100% 200 Vdc 340 Vdc 416 Vdc
168
AURORA WIND
PARAMETER
Input Side Maximum Absolute DC Input Voltage V(dc,abs) Operating DC Input Range (Vdcmin...Vdcmax) DC Input range at full power (Vfp,min...Vfp,max) Dc Power Limitation Maximum DC Input Current (Idcmax) Maximum Input Short Circuit Current DC Connection Type Input Protection Reverse Polarity Protection Input Over Voltage Protection - Varistor Generator Isolation Control Output Side AC Grid Connection Rated AC Power (Pacr) Maximum AC Output Power (Pacmax) Rated Grid AC Voltage (Vac,r) AC Voltage Range Maximum Output AC Current (Iac,max) Rated Frequency (fr) Frequency Range (fmin...fmax) Nominal Power Factor (Cosphiac,r) Total Harmonic Distortion AC Connection Type Output Protection Anti-islanding protection Maximum AC Overcurrent Protection Output Over Voltage Protection - Varistor Operating Performance Maximum Efficiency (max) Stand-by Consumption Communication Wired Local Monitoring Remote Monitoring Wireless Local Monitoring User Interface Environmental Ambient Temperature Range Noise Emission Maximum Operating Altitude with Derating Physical Environmental Protection Rating Cooling Dimension (H x W x D) Weight Safety Isolation Level Marking Safety and EMC standard Grid Standard Available Products Variants Standard
SSWI-3.8-I-OUTD
520 V 90...520 V 160...470 V Linear Derating From MAX to Null [470VVdc520V] 25 A 44 A Screw Terminal Block Cable Glands No 4 Yes Single Phase 3800 W 4200 W 230 V 180...264 V (1) 18.2 A(2) 50 Hz 47...53 Hz (3) > 0.995 < 2% Screw Terminal Block Cable Glands According to local standard 20 A 2 (L-N/L-PE) 96.8% < 8W PVI-USB-RS485_223 (opt.), PVI-DESKTOP (opt.) PVI-AEC-EVO (opt.), AURORA-UNIVERSAL (opt.) PVI-DESKTOP (opt.) with PVI-RADIOMODULE (opt.) 16 characters x 2 lines LCD display
SSWI-4.6-I-OUTD
520 V 90...520 V 200...470 V Linear Derating From MAX to Null [470VVdc520V] 28 A 44 A Screw Terminal Block Cable Glands No 4 Yes Single Phase 4600 W 5000 W 230 V 180...264 V (1) 22.5 A 50 Hz 47...53 Hz (2) > 0.995 < 2% Screw Terminal Block Cable Glands According to local standard 25 A 2 (L-N/L-PE) 96.8% < 8W PVI-USB-RS485_223 (opt.), PVI-DESKTOP (opt.) PVI-AEC-EVO (opt.), AURORA-UNIVERSAL (opt.) PVI-DESKTOP (opt.) with PVI-RADIOMODULE (opt.) 16 characters x 2 lines LCD display
-25...+60C /-13...140F with derating above 45C/113F -25...+60C /-13...140F with derating above 45C/113F < 50 dB(A) < 50 dB(A) 2000 m / 6560 ft 2000 m / 6560 ft IP 65 Natural 712mm x 325mm x 222mm / 28 x 12.8 x 8.7 20 kg / 44 lb HF Transformer CE EN 50178, AS/NZS3100, AS/NZS 60950, EN61000-6-2, EN61000-6-4, EN61000-3-11, EN61000-3-12 IP 65 Natural 712mm x 325mm x 222mm / 28 x 12.8 x 8.7 20 kg / 44 lb HF Transformer CE EN 50178, AS/NZS3100, AS/NZS 60950, EN61000-6-2, EN61000-6-4, EN61000-3-11, EN61000-3-12
Guideline ENEL, VDE 0126-1-1, AS4777, G83/1, EN 50438 Guideline ENEL, VDE 0126-1-1, AS4777, G59/2, EN 50438 SSWI-3.8-I-OUTD SSWI-4.6-I-OUTD
1. The AC voltage range may vary depending on specific country grid standard 2. Maximum Output Current Limited to 16A for G83/1 version 3. The Frequency range may vary depending on specific country grid standard
AURORA WIND
169
PARAMETER
Input Side Maximum Absolute DC Input Voltage V(dc,abs) Operating DC Input Range (Vdcmin...Vdcmax) DC Input range at full power (Vfp,min...Vfp,max) Dc Power Limitation Maximum DC Input Current (Idcmax) Maximum Input Short Circuit Current DC Connection Type Input Protection Reverse Polarity Protection Input Over Voltage Protection - Varistor Generator Isolation Control Output Side AC Grid Connection Rated AC Power (Pacr) Maximum AC Output Power (Pacmax) Rated Grid AC Voltage (Vac,r) AC Voltage Range Maximum Output AC Current (Iac,max) Rated Frequency (fr) Frequency Range (fmin...fmax) Nominal Power Factor (Cosphiac,r) Total Harmonic Distortion AC Connection Type Output Protection Anti-islanding protection Maximum AC Overcurrent Protection Output Over Voltage Protection - Varistor Operating Performance Maximum Efficiency (max) Stand-by Consumption Communication Wired Local Monitoring Remote Monitoring Wireless Local Monitoring User Interface Environmental Ambient Temperature Range Noise Emission Maximum Operating Altitude with Derating Physical Environmental Protection Rating Cooling Dimension (H x W x D) Weight Safety Isolation Level Marking Safety and EMC standard Grid Standard Available Products Variants Standard
SSWI-3.8-I-OUTD-US
520 V 90...520 V 200...470 V Linear Derating From MAX to Null [470VVdc520V] 25 A 31.2 A Screw Terminal Block 3 Knock-Outs: No 4 Yes 240 Single Phase / Split Phase 3800 W 3800 W 240 V 211...264 V 16 A 60 Hz 59.3...60.5 Hz > 0.995 < 2% Screw Terminal Block 3 Knock-Outs: According to UL 1741/IEE1547 20 A 2 (L-N/L-PE) 96.9% < 8W PVI-USB-RS485_223 (opt.), PVI-DESKTOP (opt.) PVI-AEC-EVO (opt.), AURORA-UNIVERSAL (opt.) PVI-DESKTOP (opt.) with PVI-RADIOMODULE (opt.) 16 characters x 2 lines LCD display -25...+60C /-13...140F with derating above 45C/113F < 50 dB(A) 2000 m / 6560 ft NEMA 4X Natural 712mm x 325mm x 222mm / 28 x 12.8 x 8.7 20 kg / 44 lb HF Transformer cCSAus UL 1741, CSA - C22.2 N. 107.1-01 IEEE 1547 SSWI-3.8-I-OUTD-US 4200 W 277 V 244...304 V 16 A
277
170
AURORA WIND
PARAMETER
Input Side Maximum Absolute DC Input Voltage V(dc,abs) Operating DC Input Range (Vdcmin...Vdcmax) DC Input range at full power (Vfp,min...Vfp,max) Dc Power Limitation Maximum DC Input Current (Idcmax) Maximum Input Short Circuit Current DC Connection Type Input Protection Reverse Polarity Protection Input Over Voltage Protection - Varistor Generator Isolation Control Output Side AC Grid Connection Rated AC Power (Pacr) Maximum AC Output Power (Pacmax) Rated Grid AC Voltage (Vac,r) AC Voltage Range Maximum Output AC Current (Iac,max) Rated Frequency (fr) Frequency Range (fmin...fmax) Nominal Power Factor (Cosphiac,r) Total Harmonic Distortion AC Connection Type Output Protection Anti-islanding protection Maximum AC Overcurrent Protection Output Over Voltage Protection - Varistor Operating Performance Maximum Efficiency (max) Stand-by Consumption Communication Wired Local Monitoring Remote Monitoring Wireless Local Monitoring User Interface Environmental Ambient Temperature Range Noise Emission Maximum Operating Altitude with Derating Physical Environmental Protection Rating Cooling Dimension (H x W x D) Weight Safety Isolation Level Marking Safety and EMC standard Grid Standard Available Products Variants Standard 208 30 A
SSWI-4.6-I-OUTD-US
520 V 90...520 V 200...470 V Linear Derating From MAX to Null [470VVdc520V] 28 A 34 A Screw Terminal Block 3 Knock-Outs: No 4 Yes 240 Single Phase / Split Phase 4600 W 5000 W 240 V 211...264 V 20 A 60 Hz 59.3...60.5 Hz > 0.995 < 2% Screw Terminal Block 3 Knock-Outs: 240 According to UL 1741/IEE1547 25 A 2 (L-N/L-PE) 96.9% < 8W PVI-USB-RS485_223 (opt.), PVI-DESKTOP (opt.) PVI-AEC-EVO (opt.), AURORA-UNIVERSAL (opt.) PVI-DESKTOP (opt.) with PVI-RADIOMODULE (opt.) 16 characters x 2 lines LCD display -25...+60C /-13...140F with derating above 45C/113F < 50 dB(A) 2000 m / 6560 ft NEMA 4X Natural 712mm x 325mm x 222mm / 28 x 12.8 x 8.7 20 kg / 44 lb HF Transformer cCSAus UL 1741, CSA - C22.2 N. 107.1-01 IEEE 1547 SSWI-4.6-I-OUTD-US 277 25 A
208
277
AURORA WIND
171
172
AURORA WIND
Aurora grid-tie transformerless wind inverters offer a unique combination of high efficiencies, installer-friendly designs and long service life. A major selling point of the Aurora Wind inverter is its very wide input voltage range ensuring power is continuously harvested from the lightest breeze to the strongest wind. The competitive initial acquisition costs matched with the high efficiencies of up to 96.9% significantly increase return on investment on wind-power installations. This compact, weather-sealed inverter has a programmable 16-point profile which allows a tight match for any compatible permanent magnet turbine.
Features
Single Phase Output Transformerless operation for highest efficiency Power curve customization with high granularity to reach high level of power production yield Outdoor enclosure for unrestricted use under any environmental conditions Compact size and high power density Optimized real time power curve tracking algorithm and improved energy harvesting High overload capability: works up the power max limits under most ambient conditions Compatible with 25kW Wind Interface Compatible with 7200 Wind Interface Compatible with 4000 Wind Interface
WIND
AURORA WIND 173
IN1.1(+) IN1.2(+)
BOOST 1 (DC/DC)
BULK CAPS
INVERTER (DC/AC)
IN1.1(-) IN1.2(-)
LINE FILTER
L3
IN1.1(+) IN1.2(+)
BOOST 2 (DC/DC)
PE
IN1.1(-) IN1.2(-)
RS485 + T/R - T/R RTN DC/DC DSP CONTR. DC/AC DSP CONTR. REMOTE CONTROL +R -R WT (+) WT (-) WIND SPEED INPUT
CONTROL CIRCUIT
PVI-3.6-TL-OUTD-W
100 99 98 97 Efficiency, %
Efficiency, % 100 99 98 97 96 95 94 93
200 Vdc 340 Vdc 480 Vdc
PVI-4.2-TL-OUTD-W
96 95 94 93 92 91 90 0% 10% 20% 30% 40% 50% 60% 70% 80% 90% 100%
200 Vdc
90%
100%
174
AURORA WIND
PARAMETER
Input Side Maximum Absolute DC Input Voltage V(dc,abs) Operating DC Input Range (Vdcmin...Vdcmax) DC Input range at full power (Vfp,min...Vfp,max) Dc Power Limitation Maximum DC Input Current (Idcmax) Maximum Input Short Circuit Current DC Connection Type Input Protection Reverse Polarity Protection Input Over Voltage Protection - Varistor Generator Isolation Control Output Side AC Grid Connection Rated AC Power (Pacr) Maximum AC Output Power (Pacmax) Rated Grid AC Voltage (Vac,r) AC Voltage Range Maximum Output AC Current (Iac,max) Rated Frequency (fr) Frequency Range (fmin...fmax) Nominal Power Factor (Cosphiac,r) Total Harmonic Distortion AC Connection Type Output Protection Anti-islanding protection Maximum AC Overcurrent Protection Output Over Voltage Protection - Varistor Operating Performance Maximum Efficiency (max) Stand-by Consumption Communication Wired Local Monitoring Remote Monitoring Wireless Local Monitoring User Interface Environmental Ambient Temperature Range Noise Emission Maximum Operating Altitude with Derating Physical Environmental Protection Rating Cooling Dimension (H x W x D) Weight Safety Isolation Level Marking Safety and EMC standard Grid Standard Available Products Variants Standard
PVI-3.0-TL-OUTD-W
PVI-3.6-TL-OUTD-W
PVI-4.2-TL-OUTD-W
160...530 V 20 A 25 A
600 V 50...580 V 120...530 V Linear Derating From MAX to Null [530VVdc580V] 32 A 40 A Screw Terminal Block Cable Glands No 4 Yes Single phase 3600 W 4000 W 230 V 180...264 V (1) 17.2 A(3) 50 Hz 47...53 Hz (2) > 0.995 < 2% Screw Terminal Block Cable Glands According to local standard 19 A 2 (L-N/L-PE) 96.8% < 8W PVI-USB-RS485_223 (opt.), PVI-DESKTOP (opt.) PVI-AEC-EVO (opt.), AURORA-UNIVERSAL (opt.) PVI-DESKTOP (opt.) with PVI-RADIOMODULE (opt.) 16 characters x 2 lines LCD display -25...+ 60C/-13...140F with derating above 55C/131F < 50 dB(A) 2000 m / 6560 ft IP 65 Natural 618mm x 325mm x 222mm / 24.3 x 12.8 x 8.7 17 kg / 37.4 lb Transformerless CE EN 50178, EN61000-6-2, EN61000-6-4, EN61000-3-11, EN61000-3-12
140...530 V 32 A 40 A
3000 W 3300 W
4200 W 4600 W
14.5 A
20 A
16 A
22 A
1. The AC voltage range may vary depending on specific country grid standard 2. The Frequency range may vary depending on specific country grid standard 3. Maximum output current limited to 16A for G83/1 version 4. Ask sales for availability 5. Add suffix -AU to product description
AURORA WIND
175
IN1.1(+) IN1.2(+)
BOOST 1 (DC/DC)
BULK CAPS
INVERTER (DC/AC)
IN1.1(-) IN1.2(-)
LINE FILTER
L3
IN1.1(+) IN1.2(+)
BOOST 2 (DC/DC)
PE
IN1.1(-) IN1.2(-)
RS485 + T/R - T/R RTN DC/DC DSP CONTR. DC/AC DSP CONTR. REMOTE CONTROL +R -R WT (+) WT (-) WIND SPEED INPUT
CONTROL CIRCUIT
PVI-3.6-OUTD-US-W
100 99 98 97 Efficiency, %
Efficiency, % 100 99 98 97 96 95 94 93
200 Vdc 340 Vdc 480 Vdc
PVI-4.2-OUTD-US-W
96 95 94 93 92 91 90 0% 10% 20% 30% 40% 50% 60% 70% 80% 90% 100%
90%
100%
176
AURORA WIND
PARAMETER
Input Side Maximum Absolute DC Input Voltage V(dc,abs) Operating DC Input Range (Vdcmin...Vdcmax) DC Input range at full power (Vfp,min...Vfp,max) Dc Power Limitation Maximum DC Input Current (Idcmax) Maximum Input Short Circuit Current DC Connection Type Input Protection Reverse Polarity Protection Input Over Voltage Protection - Varistor Generator Isolation Control Output Side AC Grid Connection Rated AC Power (Pacr) Maximum AC Output Power (Pacmax) Rated Grid AC Voltage (Vac,r) AC Voltage Range Maximum Output AC Current (Iac,max) Rated Frequency (fr) Frequency Range (fmin...fmax) Nominal Power Factor (Cosphiac,r) Total Harmonic Distortion AC Connection Type Output Protection Anti-islanding protection Maximum AC Overcurrent Protection Output Over Voltage Protection - Varistor Operating Performance Maximum Efficiency (max) Stand-by Consumption Communication Wired Local Monitoring Remote Monitoring Wireless Local Monitoring User Interface Environmental Ambient Temperature Range Noise Emission Maximum Operating Altitude with Derating Physical Environmental Protection Rating Cooling Dimension (H x W x D) Weight Safety Isolation Level Marking Safety and EMC standard Grid Standard Available Products Variants Standard
PVI-3.0-OUTD-US-W
PVI-3.6-OUTD-US-W
PVI-4.2-OUTD-US-W
200...530 V 20 A 25 A
600 V 50...580 V 220...530 V Linear Derating From MAX to Null [530VVdc580V] 32 A 40 A Screw Terminal Block 3 Knock-Outs: 1 or 1 (w/ Ring Red.) No 4 Yes 277 208 240 277 Single Phase / Split Phase 3600 W 3300 W 3600 W 4000 W 4000 W 277 V 208 V 240 V 277 V 244...304 V 183...228 V 211...264 V 244...304 V 12.0 A 17.2 A 16 A 16 A 60 Hz 59.3...60.5 Hz > 0.995 < 2% Screw Terminal Block 3 Knock-Outs: 1 or 1 (w/ring reducer)
200...530 V 32 A 40 A
208
240
208
277
208 20 A
240 20 A
277 15 A
208 25 A
240 25 A
277 25 A
PVI-USB-RS485_223 (opt.), PVI-DESKTOP (opt.) PVI-AEC-EVO (opt.), AURORA-UNIVERSAL (opt.) PVI-DESKTOP (opt.) with PVI-RADIOMODULE (opt.) 16 characters x 2 lines LCD display -25...+ 60C/-13...140F with derating above 55C/131F < 50 dB(A) 2000 m / 6560 ft NEMA 4X Natural 618mm x 325mm x 222mm / 24.3 x 12.8 x 8.7 18 kg / 39.6 lb Transformerless cCSAus UL 1741, CSA - C22.2 N. 107.1-01 IEEE 1547 PVI-3.0-OUTD-US-W PVI-3.6-OUTD-US-W PVI-4.2-OUTD-US-W
AURORA WIND
177
Power-One is dedicated to making sure that each of our customers enjoy uninterrupted use and production from their Aurora Inverter. By purchasing an inverter from Power-One you have joined with a team that is dedicated to making your life easy. From startup and commissioning to trouble-shooting and fault correction, our technical support team members are ready and willing to assist in answering all your installation and technical questions. At Power-One, we want to ensure that your Inverter is as productive as possible at all times. With this in mind, we gladly offer a number of key services detailed on the following pages. Power-One is continually developing new and unique services to offer our customers in order to enhance your experience and improve your productive use of our product. More details on each program within the Aurora Service system can be gained by meeting with your local representative. For Service contact details and information on Return and Repairs please see page 201.
178
AURORA SERVICE
SERVICE
AURORA SERVICE
179
SERVICE
180
AURORA SERVICE
Aurora Advantage Programs include High End Performance Guarantees, Software and Communication integration and upgrades, Variable Up Time and Productive Time Assurance Plans, Remote Monitoring & Reporting, Field and Site Optimization, Lifetime repair/ replace, Ownership Transfer Reviews, Site Certification, On Site System Maintenance, Pre-Pack Maintenance, Start Up and Commissioning, Advanced System Integration, System Maximization, and On Site Emergency Intervention. The Advantage program allows you to custom tailor your Power-One support to meet you or your clients needs. From our full a la carte menu you can pick and choose those services that best cover your current and future needs. Performance Guarantees for Central and grouped string inverters will give you the ultimate peace of mind. We will ensure productive up-time tailored specifically to your financial obligations and your corporate programs. With a combination of our offer (modularity) and our service teams located around the world, we can help you reduce or eliminate down-time from a system failure. Communication and software update programs will help you keep in touch and up to date, the advanced service allows you to have constant monitoring, system upgrades and integration services available for your complete power plant.
ADVANTAGE
Long-term and lifetime programs were developed to ensure the long term productivity of your plant. Rest assured that Power-One will have the parts, the people and the systems in place to help you maintain a long term productive plant. Maintenance programs can be tailor fit to your installation. Whether we perform on-site system maintenance or you choose our self maintenance program plans, we can help you ensure a lifetime of production for the right cost. Commissioning services will help you start out right. With our complete system check and set up plan you have the comfort of knowing we are with you every step of the way. Through or comprehensive start up procedures you will see that each component and the combined system are working properly from day one.
AURORA SERVICE
181
SERVICE
182
AURORA SERVICE
The Aurora Assure Program includes Normal Warranty Coverage, Extended Warranty Coverage, Technical Support and Call Center, On Line Support, No Fault Warranty, Mid-life Warranty Extensions, End-of-life Management, End-of-life Replacement Discount, Monitoring & System Integration. When making a large investment it is important for you to ensure the longevity and high level of production of your facility. To do this one of the first steps you need to take is to work with a strong global company with years of operating experience in the inverter business. Power-One offers the best possible solution. Standard warranties from 5 to 10 years and warranty extensions of up to 20 total years, ensure the longevity and confidence that you need. Call Center support is available from 8am-5pm every working day and the online support and FAQ system is available for you 24/7. You may also log into the system and advise us of any questions you may have and we will gladly respond within the next working day.
ASSURE
Our new online system will soon allow you to register your warranty and track your service level agreements. Any time day or night, with our fast track system you will be able to determine where your inverter is in our system at anytime during repair, ask any question you may have and request further technical support as necessary. Online training programs will also be made available to registered owners or installers.
AURORA SERVICE
183
SERVICE
184
AURORA SERVICE
We think its time for you to join us an Alliance member. More than a club, Aurora Alliance is a partnership. Membership with an industry leader has its advantages. Through our Alliance Membership, you become a part of our future. We will work with you to help increase your knowledge and capability. You will learn more about layout and design, engineering support, knowledge base access, direct line technical support, training discount, enhanced sales programs, discount on specific service offers portal based warranty registration, marketing material and more.
ALLIANCE
The Aurora Alliance programs will keep you up to date on new Aurora offers, help you market your company with the advantage of Aurora collateral and allow you to enjoy many industry specific conversations with other Alliance members, all hosted by Power-One. Always check with your local Power-One Representative for Pricing and Programs News
AURORA SERVICE
185
SERVICE
186
AURORA SERVICE
By joining the Aurora Academy you become an informed member of an elite team. Included in this program are customer and installer specific training programs: On-Site Training, arranged to help tailor the training to your teams specific needs and site specific installation, cuts to the core allowing you to learn in a live classroom. This training is one of the most effective means to ensure your power plant maintains a high level of productivity. Certification training programs are designed to bring you and your team to the next level of proficiency. Learn the ins and outs of the PV and Wind systems obtain certification and access to specific FAQs. Develop your own Train the Trainer program.
ACADEMY
Power-One also offers safety training, site maintenance training and other unique programs develop to help you improve your plants performance. Power-Ones Regional Training Centers will offer a full calendar of training events. Our course work will be offered live and online for your convenience.
AURORA SERVICE
187
SERVICE
188
190
In the past few years, the EMEA market has represented Power-Ones spring-board into the renewable energy market. Thanks to the opportunities presented by the different regional markets in our territory, we have grown to be the second largest inverter manufacturer in the world. In 2010, EMEAs market topped an impressive 16 GW worth of new installations with Germany and Italy being the leading countries with about 8.5GW and 5.5GW respectively. As more and more photovoltaic installations are being deployed within EMEA, governments are issuing new laws and regulations to tighten feed-in-tariffs to try and drive our market towards full sustainability (grid parity). This opens up several new opportunities and also some challenges. I am confident that Power-One is ready for them. Our network of partners and distributors has reached a degree of penetration throughout Italy, Germany, France, Spain, Portugal, United Kingdom, Israel and the BeNeLux, which is second to none. We are still investing in our channel, not only to enlarge our sales and service structures in those countries but also in to open up branch offices in Greece, in the Arab Emirates and in several countries in Africa. We firmly believe that the continued expansion in new markets will bring Power-One the strength and the experience which will be needed to sustain the competitive challenges that lie ahead of us. As you flip the pages of this brochure, you will see a whole host of new products that we have prepared to the usual technical and technological excellence while keeping a very close eye to competitiveness and ease of use. We are proud of our new product offering and we are convinced that it will meet the markets taste and expectations. Finally, I would like to take this opportunity to thank our entire sales force, our distribution partners, our customer service people, our technical groups and all of the customers who have placed their trust in our products and services. We wouldnt be where we are without you and you can be sure of our continued commitment to provide you with best-in-class technology, flexibility, competitiveness and service.
North America is quickly becoming the largest PV market in the world. Each month, analysts are predicting even larger totals for 2011 and beyond, currently greater than 2GW. This is twice what was predicted last year. With the price of oil again on the rise, these numbers will continue to increase. Power-One continues to increase market share in all global markets. We attained the #2 position and continue to distance ourselves those behind. Differentiated product features along with the highest reliability are making Power-One the inverter of choice. Our plan to have local manufacturing in each of the three major geographies has been executed. In North America, the Phoenix, Arizona facility is now fully operational. Scarborough, Ontario also continues to expand its support of the Canadian marketplace with each new inverter we introduce. Having local manufacturing is key to our success by providing immediate customer support, local inventory, and producing products that comply with local incentive requirements. The Power-One Aurora family of inverters continues to expand in North America. Over the past year, we have launched a new line of isolated string inverters, the modular Central inverter platform, turn-key utility scale inverters, and the worlds most popular three-phase string inverter line. Demand for our transformerless string inverters continue to grow as customers realize the advantages this topology brings. Power-One market share will continue to grow as installers and owners recognize the value of design flexibility, simplified installation, robust engineering, best-in-class efficiency, and the highest reliability. We will continue to offer innovative new products to meet evolving requirements of the North American market. All of us at Power-One are excited to be part of the Renewable Energy industry during this time of unprecedented growth. We look forward to helping our partners continue to be successful by providing the best products and services available. The future is destined to be bright.
192
Asia is a market with a vibrant mix of cultures and business challenges which are unique and full of unpredictables. At Power-One Asia, we cover more than half the population of the globe and a vast area with high growth potential. In China, where we have just opened our brand new RE factory, the market requires mainly central inverters and has to be qualified by CQC. Our PVI-250-TL and PVI-500-TL are well positioned for the China market and currently we are engaging in a lot of brand and product promotion to try to gain traction. In Australia, our string inverter has gained number one market share in 2010. With the introduction of the new 2kW inverter, we should maintain our position in 2011. In India, PVI-250 and PVI-500 have already made in road into a few solar farm projects which are bases on the CQC standard. Soon our Indian office will also be set up to cope with upcoming demands. The earthquake and nuclear crisis in Japan has shocked the market place whereby the market has temporary went to hibernation. We are seeking to work with local partners to get our string inverter certified so when the market return, we will be able to catch the initial waves. Asia is the most densely populated area on earth and yet consumption of natural resources accounts for much less than the western world. And people in this part of the world do really adopt the philosophy of living with the nature. So conservation of energy and natural resources would be a main theme of most peoples daily living. The appreciation of good technology is also a part of the culture in Asia. Power-One positions here with good history and infrastructure in place to tackle the rising demand of green energy. With the opening of our RE factory in Shenzhen, China, we can now deliver Asia-made products to the market with good technology and timely services. We believe that we can capitalize on the growing market and make good inroads with our new 250kW and 500kW utility-grade products which will bring good cost-per-watt value to our customers. Continue to Aim High is part Power-Ones sales team in Asia. We will strive our efforts with the dedicated and focus team in gaining market share in this part of the world. And different spices will need to be deployed with our strategies to win.
194
196
COntacts
CONTACTS
CONTACTS
197
198
CONTACTS
Singapore
Australia
Power-One Renewable Energy Worldwide Sales Offices Country Australia China Singapore France Germany Italy Spain United Kingdom Dubai Canada USA East USA Central USA West Name/Region Asia Pacific Asia Pacific Asia Pacific Europe Europe Europe Europe Europe Middle East North America North America North America North America Telephone +61 2 9735 3111 +86 755 2988 5888 ext.5588 +65 6896 3363 00 800 00287672 Choix n4 +49 7641 955 2020 +39 055 9195 396 +34 629253564 +44 1903 823 323 +971 50 100 4142 +1 877 261-1374 +1 877 261-1374 +1 877 261-1374 +1 877 261-1374 Email sales.australia@power-one.com sales.china@power-one.com sales.singapore@power-one.com sales.france@power-one.com sales.germany@power-one.com sales.italy@power-one.com sales.spain@power-one.com sales.UK@power-one.com sales.dubai@power-one.com sales.canada@power-one.com sales.usaeast@power-one.com sales.usacentral@power-one.com sales.usawest@power-one.com
CONTACTS
199
200
CONTACTS
Regional Inventory Power-One is building the industrys leading regional repair inventory and testing facilities. With locations in virtually every country we sell in, we can ensure a quick and efficient turnaround time on your Inverter when a repair or replacement is required. Our vast global inventory backed by four global manufacturing locations is rapidly becoming the industry standard. Repairs Power-One offers regional return and repair capability as well as special programs to help you maintain an long term relationship with your customers, including swap stock, fixed rate repairs, out of warranty programs and life cycle management programs. Please feel free to ask your local Power-One representative about details.
CONTACTS
201
Publication Information Copyright 2011 Power-One Inc. Ver. 2011-02.2-EN All rights reserved All products are subject to technical improvements without notice Publisher Power-One Inc 740 Calle Plano, Camarillo, California 93012-8583, USA Trademarks Power-One, Aurora, Aurora Uno, Aurora Trio, Aurora Plus, Aurora Station, Aurora Vision, Aurora Wind, Aurora Service, Aurora Advantage, Aurora Assure, Aurora Alliance, Aurora Academy are registered trademarks of Power-One Inc. Acknowledgements Design Luchi Design - Firenze Photography Justin Bailie Dan Patitucci Industrial Foto
202
INFORMATION
www.power-one.com