You are on page 1of 1

This drawing shows schematically the drainage facilities and minimum structural Details of the structural, geotechnical

150 DIA.

requirements.

and foundation systems are to be designed by Qualified Persons.


2.0m FOR 2.7m AND 3.0m MAINTENANCE ACCESS 3.5m FOR 4.5m MAINTENANCE ACCESS

R6 STIRRUP A A GRADE 25 CONCRETE 4 R10

4.5m FOR 6.0m MAINTENANCE ACCESS

75 x 75 x 8 THK. STEEL PLATE FIRMLY WELDED TO STEEL POST 13 DIA. GALVANISED

SECTION C - C
150 DIA.
150 DIA.

STEEL CHAIN 100 DIA (NOMINAL BORE)

600 FOR RURAL AREA

100 FOR URBAN AREA

300 / 100

1000

FIXED STEEL POST FILLED WITH CONCRETE


400

C 6mm DIA. STIRRUPS (5 NOS) 4 R10 GRADE 25 CONCRETE

TO BE PAINTED IN PEACOCK BLUE PAINT NO.0115 (BODELAC 3000 OR OTHER APPROVED EQUIVALENT)

BRASS PADLOCK

GROUND LEVEL
300 / 0 400

100

TO BE PAINTED IN WHITE

600

150mm DIA. PRECAST CONCRETE PIPE 100 FOR RURAL AREA 50 FOR URBAN AREA CAST-IN-SITU GRADE 25 CONCRETE

GRADE 20 MASS CONCRETE 100 FOR RURAL AREA GROUND LEVEL 50 FOR URBAN AREA 300
50

GROUND LEVEL

450 SQ.

600

650

650

STEEL POSTS AND CHAINS


300

200

FOR MAINTENANCE ACCESS

50

15

50 450 SQ

50

IA

450 SQ

SECTION A - A

ELEVATION
150 DIA.

(WHITE)

(BLUE)

PLAN VIEW
250

DETAILS OF DRAINAGE RESERVE CONCRETE MARKER

6 THK. M.S. PLATE WELDED TO TOP OF G.S. PIPE

250

G.S. PIPE (MEDIUM DUTY)

300x300x12 THK. M.S. STEEL PLATE WELDED TO G.S. PIPE HILTI HKD FLUSH ANCHOR-HKD M20

750

150 NOMINAL DIA.G.S. PIPE (MEDIUM DUTY) WELDED CENTRALLY ON 300x300x12 THK.

NOTES 1. ALL DIMENSIONS SHOWN ARE IN MILLIMETRES UNLESS OTHERWISE STATED. 2. MATERIALS a) ALL G.S. PIPES OR EQUIVALENT TO BE LIGHT TUBES CONFORMING TO S.S.17 b) ALL STEEL USED TO BE MILD STEEL CONFORMING TO B.S.4360 c) ALL GALVANISING TO BE HOT DIPPED GALVANISED COATING CONFORMING TO S.S.117 3. GALVANISED STEEL PIPES TO BE PREPARED a) ONE COAT OF APPROVED WASH PRIMER b) ONE COAT OF APPROVED ZINC CHROMATE PAINT c) ONE UNDERCOAT OF APPROVED OIL BASED PAINT AND PAINTED AS FOLLOWS:
450x450x300 CONC. FOOTING (CONCRETE 20) G.L.

300

M.S. PLATE

30

0
30

(BLUE)

250

12

100

G.L.
300

45

45

20 DIA. BOLT SECURED IN ANCHOR WITH BUILT-IN EXPANSION PLUG AND INTERNAL THREADS (HILTI HKD FLUSH ANCHOR-HKD M20) OR EQUIVALENT 450

ISOMETRIC VIEW

d) TWO TOP COATS OF APPROVED OIL BASED PAINT 4. ALL STEEL RODS, FLAT & SQUARE TO BE PREPARED AND PAINTED AS FOLLOWS:

SECTION X-X
DETACHABLE BOLLARD

NOTES

a) BEFORE ERECTION CLEAN WITH WIRE BRUSH TO REMOVE ALL RUST & MILL SCALE AND PAINT ONE COAT OF APPROVED PRIMING PAINT b) AFTER ERECTION PAINT ONE UNDERCOAT OF APPROVED OIL BASED PAINT AND TWO TOP COATS OF APPROVED OIL BASED PAINT

1. THREE COATS OF APPROVED OIL BASED PAINT TO BE PAINTED ON BOLLARDS. 2. STEEL BASED PLATE BOLTS AND NUTS TO BE COATED WITH BITUMINOUS PAINT.

DRAWING NO.