Feature Easy wiring Auto conguration capability (self-learning mode) Central programming of all device congurations from the panel Flexible network structure (Loop, stub, T-tap & mixed structure) All cable types usable (Shielded & Unshielded cables) Reduced programming and installation cost and time Benet
Up to 3000m line length Up to 1.5A current Up to 254 elements per loop/line Up to 127 elements per loop/line in LSN classic version
Less installation time and cost through reduced number of loops Increased number of loop powered devices
Built-in diagnosis functions Remote support is possible Short circuit isolators in each device increase system integrity and cost savings
One cable connects multiple areas Can withstand a short or open circuit at any point in the loop and all devices still function High security against tamper Easy operation Way of address setting can be chosen depending on wiring Cost efcient installation, additional security Cost efcient and time saving
Digital communication into every detector Addressable detectors Automatic or manual address setting possible One bus for intrusion, re and malfunction Remote programming and maintenance Special features LSN improved version
FS-OT-en-16_4998144899_11
FAH-T 420 Heat Detector Feature Combination of rate of rise and xed temperature measurement Central alarm LED visible from any direction 2-wire device
FAP-O 420 Optical Smoke Detector Light scattering principle Drift compensation Automatic pollution detection Central alarm LED visible from any direction 2-wire device
FAP-DO 420 Dual-Optical Smoke Detector Dual Ray technology Twolight scattering smoke sensors with different wavelengths (infrared andblue LED) Drift compensation Automatic pollution detection Central alarm LED visible from any direction 2-wire device
FAP-OT 420 Multisensor Detector Optical, Thermal Combination of light scattering principle, rateof rise and xed temperature measurement Drift compensation Automatic pollution detection Central alarm LED visible from any direction 2-wire device
FAP-DOT 420 Multisensor Detector Dual-Optical, Thermal Dual Ray technology (seeFAP-DO 420) in combination with rate of rise and xed temperature measurement Drift compensation Automatic pollution detection Central alarm LED visible from any direction 2-wire device
FAP-OTC 420 Multisensor Detector Optical, Thermal, Chemical Combination of light scattering principle, rate of rise and xed temperature measurement as well as combustion gas detection Drift compensation Automatic pollution detection Central alarm LED visible from any direction 2-wire device
FAP-DOTC 420 Multisensor Detector Dual-Optical, Thermal, Chemical Dual Ray technology (seeFAP-DO 420) in combination with rate of rise and xed temperature measurement as well as combustion gas detection Drift compensation Automatic pollution detection Central alarm LED visible from any direction 2-wire device
Benet Error free alarm signals which virtually eliminate the occurrence of false alarms Used where an open, fast-developing re might occur Detection of test re TF1
Error free alarm signals which virtually eliminate the occurrence of false alarms Used where a smoldering re might occur
Error free alarm signals which virtually eliminate the occurrence of false alarms Used where equal response to different types of re is essential Detection of test re TF1
Error free alarm signals which virtually eliminate the occurrence of false alarms Used where open, fastdeveloping res, as well as smoldering res, might occur Detection of test re TF1
Error free alarm signals which virtually eliminate the occurrence of false alarms Used in environments with varying conditions Detection of test re TF1
Error free alarm signals which virtually eliminate the occurrence of false alarms Used where CO gas might harm people Detection of test re TF1
Error free alarm signals which virtually eliminate the occurrence of false alarms Used in environments with special conditions to maintain, and where CO gas might harm people Detection of test re TF1
FS-OT-en-16_4998144899_11
FAP-OC 520 Smoke Detector Feature Light scattering principle in a virtual chamber White housing Multi-sensor detection in a combination of combustion gas and scattered-light sensor Central alarm LED visible from any direction 2-wire device
FAP-OC 520-P Smoke Detector Light scattering principle in a virtual chamber Multi-sensor detection in a combination of combustion gas and scattered-light sensor Color rings can be tted into the detector to adapt to the ceiling Central alarm LED visible from any direction 2-wire device
FAP-O 520 Smoke Detector Light scattering principle in a virtual chamber White housing Central alarm LED visible from any direction 2-wire device
FAP-O 520-P Smoke Detector Light scattering principle in a virtual chamber Color rings can be tted into the detector to adapt to the ceiling Central alarm LED visible from any direction 2-wire device
FAD-O 420 and FAD-HS 420 EN Duct Detector Use in ventilation systems with air velocities from 1m/s to 20m/s For the activation of fans, door controls or external display devices an optional relay board can be installed A clear section on the frosted cover allows to view alarm LED of integrated FAD-O 420 detector Tamper control 2-wire device
Benet Unobtrusive design Easy to clean Enhances the appearance of architecturally attractive rooms Ideal for dust-sensitive areas High stability against disturbance values
Unobtrusive design Easy to clean Enhances the appearance of architecturally attractive rooms Ideal for dust-sensitive areas High stability against disturbance values
Unobtrusive design Easy to clean Enhances the appearance of architecturally attractive rooms Ideal for dust-sensitive areas
Unobtrusive design Easy to clean Enhances the appearance of architecturally attractive rooms Ideal for dust-sensitive areas
FS-OT-en-16_4998144899_11
FAS-420-TM Aspirating Smoke Detector Feature Display sensitivity can be set to 0.05%/m light oscuration RoomIdent re localization 10 level smoke density display Innovative air ow sensor technology High Power Light Source 4-wire device Max. 8 aspiration openings and 40m or 2x25m pipe lenth
FAS-420-TP Aspirating Smoke Detector Display sensitivity can be set to 0.015%/m light oscuration 2 detector modules possible Innovative air ow sensor technology High Power Light Source 4-wire device Max. 48 aspiration openings and TP1: 300m; TP2:560m (2x280m) pipe lenth
FAS-420-TT Aspirating Smoke Detector Display sensitivity can be set to 0.0015%/m light oscuration 2 detector modules possible Innovative air ow sensor technology High Power Light Source 4-wire device Max. 48 aspiration openings and TT1: 300m; TT2: 560m (2x280m) pipe lenth
FMC-210 DM/SM Manual Call Point Different colors Single and double action Indoor and outdoor versions 2-wire device
FMC-420RW Manual Call Point Different colors Resettable or with glass pane Single-action call point Indoor and outdoor (IP67) versions 2-wire device
FMC-420RW Manual Call Point Outdoor Red color only Resettable or with glass pane Single-action version EN54-11 and EN54-17 compliant
Benet Very early smoke detection even under challanging environmental conditions Minimalization of false alarms due to intelligent signal processing Easy maintenance and service no interruption of regular operations Up to 5 rooms can be individually monitored
Very early smoke detection even under challanging environmental conditions Minimalization of false alarms due to intelligent signal processing Easy maintenance and service no interruption of regular operations 2-detector-dependency
Very early smoke detection even under challanging environmental conditions Minimalization of false alarms due to intelligent signal processing Easy maintenance and service no interruption of regular operations 2-detector-dependency
High exibility Can be used for re and other types of manual alarms
High exibility Can be used for re and other types of manual alarms
FS-OT-en-16_4998144899_11
FNM-420-A-BS-WH/ FNM-420-A-BS-RD Base Sounder Feature 2 types: red and white 90dB with current < 5mA Constant sound pressure level incase of voltage drop Immediate and permanent synchronization of different sounder groups within one loop 32 tones Different sound pressure levels Combination with detector/Beacon
FNM-420-A- WH/ FNM-420-A-RD Stand-alone Sounder Indoor 2 types: red and white 100dB with current < 5mA Constant sound pressure level incase of voltage drop Immediate and permanent synchronization of different sounder groups within one loop 32 tones Different sound pressure levels Double entry back box for simplied installation
FNM-420-B-RD Stand-alone Sounder Outdoor Red colour only Outdoor type with IP66 100dB with current <5mA Constant sound pressure level incase of voltage drop Immediate and permanent synchronization of different sounder groups within one loop 32 tones Different sound pressure levels Double entry back box for simplied installation
FNS-420-R Strobe Addressable strobe Freely congurable Combination with detector base or with LSN base sounder Low current consumption of 6mA 2-wire device
FLM-420-I2 Input Interface Module 2 monitored inputs Available as in-built, wall-mount and DIN-rail version Contact or voltage monitoring Line monitoring with use of EOL resistor 2-wire device
FLM-420-O2 Output Interface Module 2 open collector outputs Available as in-built, wall-mount and DIN-rail version Max. switchable current per output 700mA Max. switchable voltage per output 30VDC Outputs are electrically isolated from LSN-loop and short-circuit proof 2-wire device
FLM-420/4-CON Conventional Interface Module 2 re zones class B or 1 re zone class A Available as wall-mount and DIN-rail version 200mA max. supply current per Aux-output switchable Aux for resetting 4-wire detectors 4-wire device
Benet > 50 sounders per loop European tones covered Easy installation (sounder snaps into pre-installed mounting plate) Special mounting plate for surface mounted cabling Installation costs reduced by mounting detectors or beacons into the base sounder
> 50 sounders per loop Very high, consistent sound pressure level atlow power European tones covered Easy installation (comfortable back box with knock-outs and space for cabling) Very robust design
> 50 sounders per loop Very high, consistent sound pressure level at low power European tones covered Easy installation (comfortable back box with knock-outs and space for cabling) Very robust weather-proof design
Allows integration with Maximum light at 1Hz technical alarms (e.g. frequency for high level freezer, air condition) ofvisibility Low current consumption The various monitoring types ensure customized allows connection of a applications large number of peripheral elements
One class A or two class B zone Provides integration of conventional re alarm periphery into LSN systems Compatible with 2- and 4-wire detectors Can be used with a wide range of conventional detectors
FS-OT-en-16_4998144899_11
FLM-420-RLV1 Relay Interface Module Low Voltage Feature 1 low voltage relay 30V/1A LSN improved version Available as in-built, wall-mount and DIN-rail version 2-wire device
FLM-420-RLV8-S Octo-relay Interface Module Low Voltage Eight change-over contact relays provide potentialfree contact outputs Maximum switching capacity of the relays 2A / 30VDC 2-wire device
FLM-420-O8I2-S Octo-Output Interface Module with 2 Inputs Eight individually switchable open collector outputs Max. switchable current per output 700mA Outputs electrically isolated from LSN loop and short circuit proof Individually selectable monitoring functions (EOL or contact) for the two inputs each 2-wire device
FLM-420-I8R1-S Octo-Input Interface Module with Relay Individually selectable monitoring functions (EOLor contact) for eachof the 8 inputs Maximum switching capacity 2A/30VDC 2-wire device
Isolation of short circuits 1 supervised output line 2 high voltage relays on LSN-Line reversed polarity with up (240V/10A) 2-wire device to 3A 2 supervised feedback Available as surface mount lines and DIN-rail version Available as surface mount 4-wire device and DIN-rail version 2-wire device
Supervised control of signaling devices Easy monitoring and activating of signaling devices
FS-OT-en-16_4998144899_11
FLM-420-RLE-S Interface Module Feature 1 low voltage relay (30V, 1A) 2 supervised input lines 1 input line programmable as relay feedback DIN-rail mountable Delivered with housing for surface mounting
FLM-420-O1I1 Output-Input Interface Modules Open collector output electrically isolated from LSN loop and short-circuit proof Max. switchable current per output 700mA Individually selectable input monitoring functions (EOL, contact or voltage) 2-wire device
FK 100 LSN RF Interface Module Connection of up to 30wireless detectors Bi-directional data transfer 868-870MHz short range device Transmission path monitoring LSN classic 4-wire device
DOW 1171 Radio Smoke Detector Deception-proof operating behaviour High resistance to e lectro magnetic interference, temperature changes, humidity, corrosion and contamination Smoke detector with outstanding interference immunity Conntectable to FK-100-LSN
MPA Detector Remote Indicator DIN 14623, ATEX PTB01, ATEX 2163X Good visibility Elegant, robust and efcient design Easy localization of detectors Compatible to LSN-classic and LSN improved
FAA-RI 420 Remote Indicator Good visibility Elegant, robust and efcient design Easy localization of detectors Compatible to LSN-classic and LSN improved
Benet Supervision and control of external applications, e.g. extinguishing systems Conformity to VdS 2496: 2005 Low supply current
Easy expansion of existing re alarm systems High transmission and functional security Outstanding interference immunity
VdS approved Parallel indication for detectors in false ceilings Mounting in corridors or access pathways
Parallel indication for detectors in false ceilings Mounting in corridors or access pathways Cost-efcient solution