You are on page 1of 4

125BE Series

Low-Nox Residential Oil Boilers

Great for Your Home. Better for the Environment.

High Efficiencies and Low Emissions

Patented Flexible Cast Iron Resists Thermal Shock



3½" of Insulation for Superior Heat Retention

Limited Lifetime Warranty

Non-Condensing Models 89+% AFUE


Outputs of 73, 97, 118 MBH

Condensing Models 91+% AFUE


Outputs of 75, 100, 121 MBH Approved for
B5 Fuel Oil
Qualifies for 30% Federal Tax Credit

Comfortable. Efficient. Intelligent Heating.


125BE: Better for your home

Innovative, Environmentally
Technological Advantages
Friendly Technology
The Buderus 125BE boilers
represent the best of innovative Low Emission Blue Flame Burner
The state-of-the-art Low-NOx Buderus BE burner
heating technology. Designed
on the 125BE burns at lower temperatures than
in Europe, where fuel costs conventional burners. The ceramic burner tube
are significantly higher and is designed to recirculate combustion gases,
environmental regulations are which assists in vaporizing the liquid oil droplets
and lowers the flame temperature. The complete
more stringent, each 125BE combustion that results means more than just
System is designed for high efficient use of the fuel that is burned. It also means
efficiency, to maximize the nitrogen oxide — NOx — formation is inhibited, and
that virtually no soot is produced. Not only do you
heating value of every ounce
get more heat from each drop of fuel, the boiler
of fuel, and to be environmentally conscious, burning cleaner with less stays cleaner resulting in fewer service calls, plus
impact on the environment. The 125BE brings new advances in oil burning there are fewer emissions into the environment.
technology — a modern, low emission, high efficiency oil burner.

Primary Recirculating Combustion Gasses


The 125BE boilers are based on the high quality and superior reliability of
the Buderus G115, the world’s best selling oil boiler. Since 1995 over a
quarter of a million G125BE Systems have been installed. Now this proven
European technology, which is both highly efficient and environmentally
conscious, is available in North America.

Packaged together from one manufacturer, a 125BE System offers you the
Secondary Recirculating Combustion Gasses
best for your home and for the environment. Every 125BE System is factory
tested to ensure years of dependable operation.
Premixed fuel/air combustion for lower NOx
levels as well as full and complete combustion.
Each 125BE System includes: This stable oil burning means higher AFUE and
Buderus GL-180M Cast Iron Boiler BE Low-NOx Burner lower fuel consumption.

Logamatic Control Tigerloop® Ultra™


Trouble free operation with oil pre-heater, high
efficiency 10-micron filtration Tigerloop® Ultra™,
The heart of every 125BE System is the cast iron boiler. Buderus uses plug and play connections and proven technology.
its patented GL-180M flexible cast iron to ensure that the boiler resists
thermal shock. Designed without a heat-consuming refractory or target wall, Automated burner Ceramic
controller with Burner Tube
service and maintenance calls are minimized, while fuel efficiency and heat reset button

transfer are maximized. Sections are securely joined together and sealed Flame Sensor

by profiled, beveled steel push nipples ensuring a long life with no leakage.
Oil pump
Special compounds provide an exhaust gas-tight seal for safe and efficient with solenoid
valve and oil
operation. A full 3½" of thermal insulation around the boiler, including connection
hoses
underneath, virtually eliminates standby and stack temperature losses,
improving efficiency. Additionally the 8 flue baffles on a 125BE enhance heat Burner Motor
transfer and contribute to the very high AFUE. Blower

Flue gas recirculation for complete gasification


of oil droplets, clean combustion and higher
efficiencies.

Flame sensor photo cell


Unparalleled Energy Efficiency
Need Hot Water?
No matter how much you want to save, keeping your home comfortable and
warm is a high priority. You can do both with a Buderus 125BE System. A
125BE System will use less fuel than even a new conventional boiler, and will Pairing a Buderus domestic hot
run as clean and efficiently 20 years from now as it did the first year. water tank with a 125BE
boiler will extend your
savings to your hot water
Even More Efficiency with
needs. A Buderus tank
Condensing Technology is so well insulated that it
The GB125BE starts with all the loses less than ¼ºF per
innovative features of the G125BE and hour. Available in a vertical
adds condensing technology — the model and a space-saving
horizontal model that
latest in fuel savings. At 89% the
installs under the boiler,
G125BE already has the industry’s
these tanks have a
highest AFUE for a non-condensing higher recovery rate than
Cut-a-way view of GB125BE
boiler. Adding condensing technology to stand-alone or tankless

showing the condensing create the GB125BE now increases coil models. This Buderus
Secondary Heat Exchanger.
AFUE to over 91%. System will give you years of
consistant high efficiency with minimal service calls.

Intelligent Heating − Added Comfort


Each 125BE comes with a Logamatic 2107. This weather responsive
energy management system, with its microprocessor-based controls, will The Ultimate in
intelligently control both your heat and domestic hot water. The Logamatic Fuel Conditioning
2107 has options available for room sensor
and the ability to control a mixing station A Tigerloop® Ultra™ oil de-aerator and high
for mixed temperature applications. efficiency oil filter comes standard on every 125BE.
This guarantees only conditioned oil is delivered to
Logamatic 2107 features include: the burner, resulting in additional
fuel economy, plus a cleaner burn,
Domestic hot water priority Outdoor reset with lower emissions. In addition,
Condensate protection Vacation mode your heating contractor will
appreciate its ease of
DHW recirculation pump operation LCD display
installation and maintenance,
Automatic Summer/Winter Compatible for integration of
simple routing of oil lines,
change over solar panels
easy mounting on the side of
the boiler, as well as a vacuum
Designed for Easy Installation & Maintenance for All Applications gauge to indicate the condition of
A 125BE System is ideal for new installations or as a replacement boiler. the filter and a viewing window
Two CSA approved venting options for the G125BE and 3 concentric vent showing the condition of the oil.

options for the GB125BE allow a wide range of installation possibilities.

Standard features on a Buderus 125BE System include integrated handles


for ease of transporting, adjustable rubber screw-in feet for leveling,
rear tappings and flue connection for efficient piping, baffles and clips for
adjusting stack temperatures, a reversible full “swing” burner door, as well
as front access plugs.
125BE Series: Low-NOx Residential Oil Boilers
CONVENTIONAL CONDENSING
Model G125BE/21 G125BE/28 G125BE/34 GB125BE/22 GB125BE/30 GB125BE/35
Performance Data 131/86˚F 176/140˚F 131/86˚F 176/140˚F 131/86˚F 176/140˚F
Gross Output (MBH) 73 97 118 76* 75 102* 100 124* 121
Net IBR (MBH) 63 84 103 67* 65 90* 87 109* 105
# of Sections 3 4 5 3 4 4
Firing Rate (GBH) 0.60 0.75 0.95 0.60 0.75 0.95
AFUE % 89.8 89.4 89.1 91.2 91.1 91.0
Piping Connections
Vent Connection Size 5" 5" 5" Buderus concentric 80/125 Buderus concentric 80/125 Buderus concentric 80/125
Supply 1¼" 1¼" 1¼" 1¼" 1¼" 1¼"
Return 1" 1" 1" 1" 1" 1"
Dimensions
Total Boiler Length (L) 34⅝" 39 ⅜" 44" 37½" 42 ⅜" 42 ⅜"
Boiler Block Length (LK) 21⅛" 25 ¾" 30½" 25¾" 30½" 30½"
Boiler Feet Spacing (FL) 11⅜" 16⅛" 20 ⅞" 11⅜" 16⅛" 16⅛"
Dry Weight (lbs.) 386 459 513 423 503 503
* IBR/Gama numbers are only tested and certified at the 176/140˚F temperatures. These numbers are based on internal testing.

Abbreviations
VK Boiler Supply
VS Connection (plugged)
RK Boiler Return
RS Connection (plugged)
Boiler Drain
EL
(Connection for drain valve)
VSL Connection (plugged)

FRONT BACK - G125BE BACK - GB125BE SIDE

Clearance Requirements

Galvanized Flex Insulated


Front Side Rear Top
Vent Pipe Oil Vent

24" 15" 20" 6" 18" 1"

G125BE Venting Information


One of the two CSA certified
terminations are required for use
with G125BE series boilers for direct
vent applications. Both terminations
require 1" clearance. Chimney
venting is also possible. AT-4 AerocowlAT-4
Termination
Aerocowl Termination FT-4 Concentric
FT-4
Pipe-in-Pipe
ConcentricTermination Full swing
Pipe-in-Pipe Termination burner door for superior access
Venting Information
Venting Information

CSA approvedCSAwith approved


two 4" 90°with
elbows,
two 4"and 90°upelbows,
to 6' ofand4" regular
up to 6'smoke
of 4" regular
pipe forsmoke
short vent
pipe for short vent
One of the twoOneCSA of the two CSA
runs. For longer
runs.
runsFor
uselonger
up toruns
10' of
use flexible
up to stainless
10' of flexible
steelstainless
insulatedsteel
oil vent.
insulated oil vent.
certified terminations
certifiedare
terminations are
GB125BE Venting Information required for use
required
with for use with
Use 4" metal pipe
Use for
4" metal
air intake.
pipe Use
for air
at intake.
least 6'Use
to 8'atofleast
4" metal
6' to pipe
8' of for
4" metal
air intake
pipeinfor air intake in
G125BE seriesG125BE
boilers for
series boilers for
There are three concentric vent conditioned space
conditioned
in cold climates
space in (below
cold climates
–20 ºF)(below –20 ºF)
direct vent applications.
direct vent applications.
options: horizontal, vertical through Direct vent burners
Directare
vent
equipped
burnerswith
are equipped
pre-purgewith cycles
pre-purge
for safe,cycles
complete
for safe,
exhaust
complete
Both terminations
of all exhaust of all
Bothareterminations
“zero are “zero
clearance” systems
clearance”
for easy
systems for easy
combustion products,
combustion
whileproducts,
cooling oil
while
burner
cooling
nozzle
oil for
burnerpositive
nozzleshut-off.
for positive shut-off.
the roof, or through the chimney. The and versatile applications.
and versatile applications.

venting kits provide the basic material


needed, your application may need
additional venting accessories. Htk Concentric Side Wall Kit DO Concentric Vertical Venting Kit GA-K Concentric Vertical Chimney Kit

Bosch Thermotechnology Corp. Subject to change without notice


50 Wentworth Avenue Londonderry, NH 03053 © 2009 Bosch Thermotechnology Corp.
Tel: (603) 552-1100 Fax: (603) 584-1681 www.buderus.net Part Number 44499063 03/09