1. Overview
GSM/GPRS Series Smart Gas Meter is a new generation intelligent gas meter developed by Holley, which evolved on prepaid gas meter. It adopts Siemens GSM Module 900/1800/1900Mhz communication module to send consumption data timely to the data center. This AMR technology will make operators benefit from recording the load profile and Input-Output Ratio online.
2. Conform Standards
MID 2004/22/EC and EN12405; IEC 60079-0, 11; UNICN13757, IEC60870;
3. Main Feature
3.1 Working principle
GAS METER WORKING DIGRAM
DEVIATION10PPM (Monthly maximum datetime allowed deviation1minute)
GSM?GPRS
COMMUNICATE
REAL-TIME CLOCK
MAIN BOARD
ELECTRO VALVE
POWER SUPPLY
LCD/ALARM
1. with pressure presetting, 2. USE Pt trasducer(platinum resistence) to measure Temperature , then correct the Correctedted the metrology data To STANDARD condition
MCU: Using TI or MICROCHIP Companys SCM, low power dissipation and high performance.
Powered by built-in 12AH li-battery, service life >10 years Using mature dual reed switches measuring technology. Communication Module: GSM 900/1800/1900MHz Electro-valve: high reliable, lower voltage loss, low power dissipation. Clock Module: Using high accuracy clock chip from Dallas Company, clock offset10PPM.
3. 3 Tariff Calculation
Following parameters can be recorded automatically: Users information in five different time intervals. Time point of calculating could be preset. Gas consumption records of recent one hundred days could be saved and easy to get the gas consumption curve at any time interval.
can be re-opened by pressing the trigger button or switching off and switching on the power supply.
3.6 Display
Our gas meter has both register display and LCD display. Without users operation on meter, LCD screen will keep shut in order to preserve battery power. When display button being pressed down, LCD screen will light on. After releasing display button for sixty seconds, meter will enter low power consumption mode, at the meantime LCD screen shuts down. The default display content is accumulated gas consumption. By keep pressing the display button, other information will display in turn. Displaying information is
accumulated gas consumption, recent month gas consumption, present time, gas meter serial number.
Whether operation of Valve is normal or not. Whether the condition of memory is normal or not. Whether the condition of measuring sensor is normal or not. Whether the parameters of internal operation are normal or not.
electro-valve will shut down automatically due to users illegal operation or gas meter fault. After fault being ruled out, user can make an application of re-open valve to administration centre, and administration centre can authorize user through long distance. After accepting the authorization, then user can open the valve by pressing the button on the gas meter.
4.2 Functions 4.2.1 Support working in SMS mode or GPRS mode 4.2.2 Support setting of intervals for collecting and uploading data 4.2.3 Support checking of local GSM signal strength 4.2.4 Support remote reading of gas meter ID 4.2.5 Support local and remote time calibration
4.2.6 Support local storage of collected data, which memory can be extended as per
customer requirement
4.2.7 Support real-time battery indication. The low battery threshold can be configurable
to alert the users to change the battery.
4.2.8 Support setting of system working hours for extending battery life
NULL
Voltage Testing
Battery Input
Gas meter data acquisition interface Clock Battery RS232 interface Hardware Clock MCU Siemens module system
LED Indication
LED Indication
4.4 Main functions 4.4.1 Low consumption: The DTU can be waked up passively by the gas meter or
actively by the system on schedule. In working mode, the DTU can passively accept the gas meter push data or actively pull to read the gas meter data
4.4.2 High capacity data storage: According to the protocol, the data stored can be read
through RS232 interface and the memory can be extended according to the data volume.
4.4.3 Working mode setting: The DTU can work in SMS mode or GPRS+SMS mode. 4.4.4 SMS center setting: Maximum 15 bytes. Please consult the local mobile operator
to get the parameter.
4.4.5 Group SMS: Users can specify more than one data centers to upload the data to
multiple data center servers.
4.4.6 Interval of data acquisition: 10-50000 min as per customer requirement. The
battery life can be extended if the interval is set to be longer.
4.4.7 Interval of data uploading: 10-50000 min. 10-50000 min as per customer
requirement. The battery life can be extended if the interval is set to be longer.
4.4.8 DTU online time: 30-1800 sec. The energy consumption of the module can be
controlled in order to extend the battery life.
4.4.9 SMS data processing mode: It supports transparent mode and local storage mode;
if the data cannot be uploaded due to network failure, the data can be stored in local memory to ensure that the data will not be lost.
4.4.10 DTU ID: 12 byte for DTU ID; the local gas meter address can be inquired. 4.4.11 GSM status: Users can inquire the GSM signal strength to avoid low
communication success rate caused by the poor quality of local network.
4.4.12 Battery level inquiry: Users can set a threshold to trigger the low battery
alarming and inquire the voltage of the battery. In low battery mode, reminders will be sent to the users for battery replacement.
The system works in three working modes: Sleeping mode, data-receiving mode and data-uploading mode. Workflow: After the system is powered, the DTU enters the data-receiving ready mode. If no data is received, it enters the sleeping mode. When the DTU is in sleeping mode, the system can be waked in two ways: 1: The system can be waked by the gas meter module to enter the data-receiving mode. It returns to sleeping mode after the data receiving is completed. The waking time interval is set according to the data-acquisition interval of the gas meter. 2: The system enters data-uploading mode. After the data uploading is completed, it enters the sleeping mode again. 4.5.3 Battery Consumption Analysis We use 12AH high power lithium battery which is very popular and easy to be sourced in the market. Working parameter and mode: Interval of data acquisition: 180 min, uploading interval: 4320 min (3days)DTU online time: 300 sec. Based on the above parameters, the system can work for 9 years.
The tree structure in the left includes all the node names and the corresponding phone numbers. If the SMS mode is selected, the messages should be sent according to the format as below: Header of SMS uplink frame + SMS content The SMS uplink frame starts like this: SMSsend13116742086F, among which SMSsend is the beginning, followed by 3-15 byte target phone number and ended up with F, and plus the content to be send. For example, to set the working mode of the data center, assume the password is 123456 and working mode 1. Then format of SMS message is: SMSsend13116742086F*SET123456WKMD=1& Responding frame of server DTU for downlink data The frame header returned: SMSback13116742086F For example: SMSsend13116742086F*SET123456WKMD=1& Responding data:
5.1 The DTU Formats of Downlink SMS message format mainly includes 4 types: reading format, setting format, special format and sending format.
5.1.1 SMS format outline SMS format setting: *read-write operationpassword of 6 digit one or >one query items&,the query items are separated with #. Starting symbols *
Read-write operation GET&SET 6 digit password: admin password is HTGPRSinitial password is 000000. One or >one query items: the parameters are separated with #. Ending symbol & After read-write success, a SMS will be returned. 5.1.2 SMS setting A SMS will be returned after successful setting For example: To set the IP address of data center, imagine the password is 123456,IP address is 192.168.1.1,then the SMS format is : *SET123456DCIP=192168001001& To set the serial interface number of data center, imagine the password is123456 serial interface number is2008 then the SMS format is *SET123456DCPT=02008& To set multiple data formats, imagine the password is 123456,IP address is 192.168.1.1, the communication port number of data center is 2000the APN is CMNET heart beat cycle is 8, then the format is: *SET123456DCIP=192168001001#DCPT=02000#GAPN=CMNET#HBCY=5& 5.1.3 SMS Read
To read the IP address and the communication port number of data center, imagine the password is123456, the read format and returned SMS format are : Read *GET123456DCIP& Responding *GETDCIP=192168001001# To read multiple parameters, imagine the password is123456 the read format and returned SMS format are : Read*GET123456DCIP#DCPT#GAPN#HBCY& Responding *GETDCIP=192168001001&DCPT=02000&GAPN=CMNET&HBCY=005# 5.1.4 Special command Re-link GPRS network command. *SET123456RLIK& Re-linked GPRS network command returned *SETOK#>>12345678RELIKING 5.1.5 Sending message The data sent is the data set in the textbox, either HEX or asc. SMSsend13116742086F123456789
8. Note
DTUfull name: Data Transmission unit DTU terminal ID: Set by user, the ID of the module SMS : Text message Working mode : SMS mode &GPRSTCPUDPmode; In SMS mode, only SMS function supported.
9. Network topography
client
router
internet
CDMA/GSM/GPRS
operator
operator
operator
Before deploying smart gas meter, Operator should set up customer profile in the management system, and then write user information into SIM Card. Once this SIM card is inserted into smart gas meter, smart gas meter complete its register process.
Accuracy Class
Class 1.5
5TOD intervals
Backup Battery
0.5s/d(23)
Batterys Life
THAN YEARS
10
10 A
-20 ~50
93%
BB
0.01 m3
Item Nominal flow-rate (Qn) Maximum flow-rate (Qmax) Minimum flow-rate (Qmin)
Total pressure absorption Pa Operation pressure range Cyclic volume Permiss ible error QminQ<0.1Q max 0.1QmaxQQ max kPa dm3 % % dm3 m3 mm
Min. recording reading Max. recording reading Operational ambient temperature Storage temperature Central distance Connection thread Dimension Weight
Quality steel sheet, thickness is 0.8mm 15 Polyester powder plastics coating (gray) Printed index cover of polycarbonate or index cover of aluminum bezel with glass.