ACCEPTANCE TEST PROCEDURE

PROJECT NAME:

TELKOMSEL 2G EQP #7 SUMALIRJA 2012 Project ID Contract No


Area Name Site Name Site ID Band / BTS Type

: 397-12-09-UPX-D20057-10-09-NSC-D2 : HOT12090421 - 42310001382-384


: Central Sulawesi : Repeater Tanjung Penyu : TLI009 : DCS / OUTDOOR CUSTOMER:

PT. TELEKOMUNIKASI SELULAR

ZXSDR B8900 Acceptance Test Record

For Internal Use Only

ZXSDR BS8900 Outdoor Macro BTS Acceptance Test Record


(2010-V1.0)

Contract No. Project Name Party A Date of Acceptance

HOT12090421 - 423 2G EQP #7 sumalirja 2012 ______________________ ________________

ZTE CORPORATION

Confidential and Proprietary Information of ZTE CORPORATION.

ZXSDR B8900 Acceptance Test Record

For Internal Use Only

Legal Information
All rights reserved. No part of this documentation may be excerpted, reproduced, translated, annotated or duplicated, in any form or by any means without the prior written permission of ZTE Corporation.

and are the registered trade marks of ZTE Corporation. The names and logos of ZTE products are proprietary logos or registered trade marks. The names of other products and companies mentioned in this manual may be proprietary to their owners respectively. Without the prior written permission of ZTE or the owners of third-party trade marks or trade names, this manual does not grant the reader any permission or right to use any marker appeared in the manual.

The product described herein conforms to the design requirements of environment protection and human security. The storage, usage, and discard of the product shall comply with the manual, related contract, or laws and regulations of related countries.

The actual product may differ from what is described in this standard due to frequent update of ZTE products and fast development of technologies. Please contact the local ZTE office for the latest updating information of the product.

For the latest document http://tsm.zte.com.cn

information,

please

visit

our

website:

Confidential and Proprietary Information of ZTE CORPORATION.

ZXSDR B8900 Acceptance Test Record

For Internal Use Only

Feedback Table
You are invited to give your suggestions and opinions to improve ZTE user manuals and enjoy better service by sending emails to zheng.junhua@zte.com.cn. Thank you for your cooperation!
Document Name Product Version No. Please provide your information for further contact: Name Post Code Tel Very Good General View Work instruction Convenient to consult Comments Complete test items Feasibility of test items Well-organized structure You may give suggestions from any perspective such as the content, structure, details, depth, expression, figures/tables, special tools, FAQ and so on. The suggestions are not confined to this document. Company Address E-mail Good Ordinary Bad Very Bad ZXSDR BS8900 Acceptance Test Record Document Version No. V1.0

Suggestions

Confidential and Proprietary Information of ZTE CORPORATION.

ZXSDR B8900 Acceptance Test Record

For Internal Use Only

Revision Records
Document Version No. V1.0 Prepared/ Revised by Zhao Yanghao Prepared/Revised on May 29, 2009 Total Pages 15 Reason for Revision New Contents of Revision (Key Points Only)

Note 1: This table must be completed before updating the archived document (the document archived in the archival room of the division or the Company). Note 2: Fill "None" in "Reason for Revision" and "Contents of Revision" when archiving this document for the first time.

Confidential and Proprietary Information of ZTE CORPORATION

ZXSDR B8900 Acceptance Test Record

For Internal Use Only

Preface
This Acceptance Test Record is made upon the actual condition of ZXSDR BS8900 product. It is used during the acceptance test for BS8900 equipment.

Confidential and Proprietary Information of ZTE CORPORATION

ZXSDR B8900 Acceptance Test Record

For Internal Use Only

Project Acceptance
User Name Start date Principal: Users team members Participants: Project name Finish date

Principal:

ZTEs team members

Participants:

Principal:

Supervisors team members

Participants:

Principal:

Construction technicians

Participants:

Remarks

Confidential and Proprietary Information of ZTE CORPORATION

ZXSDR B8900 Acceptance Test Record

For Internal Use Only

Note: This Test Record covers all test items for the whole set of products. Test items should be
selected according to equipment functions purchased against the contract and the project type (expanded or reformed).

Basic information
Site No. Site name Site type Letawa DCS

S x/x/x Site configuration O x

0/4/4

_________

BTS version information

Confidential and Proprietary Information of ZTE CORPORATION

ZXSDR B8900 Acceptance Test Record

For Internal Use Only

Reliability Test
Item No. 1-1 Test Item Input Power Test The voltage of DC input 1-1-1 Input power test of BS8900 power supply of BS8900 is in the range of 40 V ~ 57 V. 1-2 Power-off and Restart Test 1. The BS8900 can be started alarms 2. The calls can be normally made/received. 1-3 Transmission Interruption Test 1. After the transmission of BS8900 is interrupted, BS8900 has no signal. 1-3-1 Transmission interruption test of BS8900 2. After the transmission is recovered, BS8900 works normally and processes calls properly. 1. If the optical fiber of RSU is disconnected, the corresponding sector has no signal. 1-3-2 Fiber disconnection test of RSU 2. Once the optical fiber connection is restored, RSU works normally and calls can be made in corresponding sectors. 1-4 Board Switchover Test 1. The switchover is 1-4-1 Switchover test of CC board successful. 2. The calls are still held after the Confidential and Proprietary Information of ZTE CORPORATION 3 Pass Fail Pass Fail successfully Pass Fail without new un-cleared 1-2-1 Power-off test of cabinet Pass Fail Test Standard (Optional) Result Conclusion Remarks

ZXSDR B8900 Acceptance Test Record Test Standard (Optional) switchover. 3. New voice calls can be made. 1-5 Board Restart Test 1. The calls can be made or received normally. 2. In case of active/standby CC 1-5-1 Plugging/unplugging test CC board configuration, when the standby CC is unplugged, a call can be held. 3. After the system recovers, there is not any new un-cleared alarm. 1. The FS board restarts successfully, and there is no alarm at 1-5-2 Reset test of FS board the foreground and OMC after the restart operation. 2. Calls are tested to be normal. 1. The SA board restarts successfully, and there is no alarm at 1-5-3 Reset test of SA board the foreground and OMC after the restart operation. 2. Calls are tested to be normal. 1. The PM board restarts successfully, and there is no alarm at 1-5-4 Reset test of PM board the foreground and OMC after the restart operation. 2. Calls are tested to be normal. 1-5-5 Reset test of RSU board 1. The RSU board restarts successfully

For Internal Use Only

Item No.

Test Item

Result

Conclusion

Remarks

Pass Fail

Pass Fail

Pass Fail

Pass Fail

Pass Fail 4

Confidential and Proprietary Information of ZTE CORPORATION

ZXSDR B8900 Acceptance Test Record Test Standard (Optional) with automatic calibration completed, and there is no alarm at the foreground and OMC after the restart operation. 2. Calls are tested to be normal.

For Internal Use Only

Item No.

Test Item

Result

Conclusion

Remarks

OMC Function Test


Item No. 2-1 Test Item Configuration Management Test 1. BBU and RSU configurations can be made in OMC. 2-1-1 Configuration Management Test 2. Configuration data can be synchronized to the foreground. 3. Voice calls are normal. 2-2 Version Management Test 1. All board versions of BS8900 can be distributed and activated. 2-2-1 Version Management Test 2. Once BS8900 starts normal operations, all running versions of its boards are consistent to the distributed versions. Pass Fail Pass Fail Test Standard (Optional) Result Conclusion Remarks

Relay Alarm Test


Item No. 3-1 Test Item Access control of the equipment room Test Standard (Optional) 1. If the access control of the equipment room Result Conclusion Pass Fail 5 Remarks

Confidential and Proprietary Information of ZTE CORPORATION

ZXSDR B8900 Acceptance Test Record Test Standard (Optional) is powered on, OMC shows the access control alarm of the site. 2. Once the access control of the equipment room is powered off, the access control alarm of the site is cleared from OMC. 1. If some smog is produced to the site, OMC shows the smog 3-2 Smog alarm of the site. 2. Once the smog disappears, the smog alarm of the site is cleared from OMC. 1. If the flooding sensor is soaked into water, OMC site. 2. Once the flooding sensor is dried up, the flooding alarm of the site is cleared from OMC. 1. If the monitored air conditioner is powered off, OMC shows the air conditioner alarm of the site. 3-4 Failure of air conditioner 2. Once the monitored air conditioner is powered on again, the air conditioner alarm of the site is cleared from OMC. shows the flooding alarm of the 3-3 Flooding

For Internal Use Only

Item No.

Test Item

Result

Conclusion

Remarks

Pass Fail

Pass Fail

Pass Fail

Call Service Test

Confidential and Proprietary Information of ZTE CORPORATION

ZXSDR B8900 Acceptance Test Record Item No. 4-1 Test Item Service call Origination attempts: Successes: Failures: Release attempts: Successes: Local MS 4-1-1 subscriber serves as calling part Failures: Service quality: No audio signal Monolog Cross talking Echo Background noise Audio discontinuity Origination attempts: Successes: Local MS 4-1-2 subscriber serves as called party Failures: Release attempts: Successes: Failures: Average rate: Calling timeslot: 4-1-3 Timeslot call Normal timeslot: Abnormal timeslot: 4-2 Data service call GPRS test: PING test PING times: Average packet loss ratio: Uploading file size: 4-2-2 GPRS test: FTP test __ Average uploading rate: __ Confidential and Proprietary Information of ZTE CORPORATION __ Uploading time: Test Standard (Optional) Result

For Internal Use Only Conclusion Remarks

Pass Fail

Pass Fail

Pass Fail

4-2-1

Pass Fail

Pass Fail

ZXSDR B8900 Acceptance Test Record Item No. Test Item Test Standard (Optional) Result Downloading file size: __ Downloading time: __ Average downloading rate: Website homepage average display time: 4-2-3 GPRS test: HTTP test __ Website login success ratio: __ Page refresh success ratio: __ WAP homepage average login time: 4-2-4 GPRS test: WAP test __ WAP website login success ratio: __ Page refresh success ratio: __ __ __ __ __

For Internal Use Only Conclusion Remarks

Pass Fail

Pass Fail

Handover Test
Item No. Test Item Test Standard (Optional) Result Handover times: Intra-BTS intercell handover The speech does not interrupt during the handover. The voice is clear. __ ___ __ __ Pass Fail __ Success times: Failure times: Conclusion Remarks

5-1-1

Power Test
Confidential and Proprietary Information of ZTE CORPORATION 8

ZXSDR B8900 Acceptance Test Record

For Internal Use Only Conclusio n Pass Fail

Item No.

Test Item

Test Standard (Optional)

Result TRX power output

Remarks

6-1-1

BTS TRX output power test

:_____/_____/____ :_____/_____/____ :_____/_____/____

Coverage Test
Item No. Test Item Test Standard (Optional) Result Conclusion Pass Fail Remarks Please fill the attached Coverage Test Record.

7-1-1

Cell coverage

Confidential and Proprietary Information of ZTE CORPORATION

ZXSDR B8900 Acceptance Test Record

For Internal Use Only

Acceptance conclusion
Conclusion:

Tested by:

Date:

Confidential and Proprietary Information of ZTE CORPORATION

10

ZXSDR BS8900 Environment Acceptance Report

For Internal Use Only

ZXSDR BS8900 Outdoor Macro BTS Environment Acceptance Report


(2010-V1.0)

Contract No. Project Name Party A Date of Acceptance

HOT12090421 - 423 2G EQP #7 sumalirja 2012 ______________________ ________________

ZTE CORPORATION

Confidential and Proprietary Information of ZTE CORPORATION.

ZXSDR BS8900 Environment Acceptance Report

For Internal Use Only

ZXSDR BS8900 Outdoor Macro BTS Environment Acceptance Report (2009-V1.0)


Planned by: Complied by: Reviewed by: * * * * GSM Customer Service Dept., Mobile Product Support Center Liu Jiangning Zhao Yanghao

ZTE CORPORATION Address: Post code: ZTE Plaza, Keji Road South, Hi-tech Industrial Park, Nanshan District, Shenzhen, P.R. China 518057 http: //tsm. zte. com. cn 800-830-1118

Technical support website: Hotline: Fax: * *

+86 755 26770800

+86 755 26770801 * *

Confidential and Proprietary Information of ZTE CORPORATION.

ZXSDR BS8900 Environment Acceptance Report

For Internal Use Only

Legal Information
All rights reserved. No part of this documentation may be excerpted, reproduced, translated, annotated or duplicated, in any form or by any means without the prior written permission of ZTE Corporation.

and are the registered trade marks of ZTE Corporation. The names and logos of ZTE products are proprietary logos or registered trade marks. The names of other products and companies mentioned in this manual may be proprietary to their owners respectively. Without the prior written permission of ZTE or the owners of third-party trade marks or trade names, this manual does not grant the reader any permission or right to use any marker appeared in the manual.

The product described herein conforms to the design requirements of environment protection and human security. The storage, usage, and discard of the product should comply with the manual, related contract, or laws and regulations of related countries.

The actual product may differ from what is described in this standard due to frequent update of ZTE products and fast development of technologies. Please contact the local ZTE office for the latest updating information of the product.

For the latest document http://tsm.zte.com.cn

information,

please

visit

our

website:

Confidential and Proprietary Information of ZTE CORPORATION.

ZXSDR BS8900 Environment Acceptance Report

For Internal Use Only

1. Introductory Remarks
The check items fall into two categories: numbered compulsory items starting with C (compulsory for all offices) and numbered general items starting with G (relatively less strict for small-scale offices). Each item is subject to two acceptance checks (the first check takes place during the project survey and the second check is before the commencement of the project). For each check, an acceptance check conclusion must be worked out and signed by both parties. For any failed item, the expected completion time approved by the user should be indicated.

2. Acceptance Contents
Site Name: __________________
Item No. Requirements The civil engineering for the 1.1C antenna feeder system has been completed, and the internal decoration has been complete. The area of the installation position and passages should 1.2C facilitate and moving, meet the installation, project and maintenance of equipments, requirements. The equipment room should be equipped with two types of 1.3C Equipment installation environment 1.4C illumination facilities: common lighting and emergency lighting. Protective grounding cables and working grounding cables should be connected in the equipment room. Water supply pipes, drain pipes, 1.5G gas pipes or fireproof pipes are forbidden to be installed in the equipment room. All of the holes in the equipment 1.6C rooms must be sealed except the airways. When technical holes passing through 1.7C the outside wall, Pass Expected date: Fail completion Pass Expected date: Fail completion measures must be taken to prevent water from entering the room. Confidential and Proprietary Information of ZTE CORPORATION. Pass Expected date: Pass Expected date: Pass Expected date: Pass Expected date: Fail completion Fail completion Fail completion Fail completion Pass Expected date: Pass Expected date: Pass Expected date: Pass Expected date: Fail completion Fail completion Fail completion Fail completion Pass Expected date: Fail completion Pass Expected date: Fail completion Pass Expected date: First Check Fail completion Second Check Pass Expected date: Fail completion

ZXSDR BS8900 Environment Acceptance Report Item No. The 1.8G Requirements floor for meet bearing storing the capacity
2

For Internal Use Only Second Check Pass Expected date: Fail completion

First Check Pass Expected date: Fail completion

should be over 450 kg/m . The location should battery design

requirements. It is recommended that the width 1.9G of master doors should be no less than 800 mm to facilitate equipment transportation. AC power supply with enough capacity for this project has been 2.1C led into the equipment room and its voltage range is 380V10% Peripheral equipment (power supply) 2.2C or 220V10%. DC power distribution box Pass Expected date: Fail completion Pass Expected date: Fail completion should be installed. Its capacity and the terminals should be available and sufficient for this project. The voltage is -48V (-57~ -40V is allowable) or +24V (+19V~+29V is allowed). Transmission Peripheral equipment (Transmission) 3.1C equipment with Pass Expected date: Fail completion Pass Expected date: Fail completion sufficient capacity and terminals should be ready and meet the requirements transmission. Storage explosive 4.1C of flammable in or the Pass Expected date: Pass Expected date: Pass Expected date: Pass Expected date: Fail completion Fail completion Fail completion Fail completion Pass Expected date: Pass Expected date: Pass Expected date: Pass Expected date: Fail completion Fail completion Fail completion Fail completion materials of BTS Pass Expected date: Fail completion Pass Expected date: Fail completion

equipment room is prohibited. The fire extinguishers must be equipped in the room. The power sockets for different

4.2C Security

voltages in the equipment room should bear clear labels. Storage of signal jamming

4.3C

source in the equipment room is prohibited. The equipment room should be equipped with alarm devices

4.4G

such as smoke sensor and temperature sensor, which should be in good condition.

Confidential and Proprietary Information of ZTE CORPORATION.

ZXSDR BS8900 Environment Acceptance Report Item No. Requirements The surrounding area of the equipment room should be free 4.5G from high-voltage power cables, intense magnetic field, or strong electrical sparkles. The decoration materials should 4.6G satisfy the fireproof requirements, and should not produce toxic substance. The lightning-protection ground 5.1C Grounding system 5.2C Ground resistance should be Note less than 5 . of the building from should the be separated ground. working Pass Expected date: Pass Expected date: Pass Expected date: The 6.1C installation meet height the and Pass Expected date: Fail completion location of the antenna pole should design requirements. The lightning rod should be fixed above the antenna to cover the antenna within its protection 6.2C Antenna feeder system range. In the plain, the protection angle should be within 45 . And in high mountains
o o

For Internal Use Only Second Check

First Check

Pass Expected date:

Fail completion

Pass Expected date:

Fail completion

Fail completion

Pass Expected date:

Fail completion

Fail completion

Pass Expected date:

Fail completion

Fail completion

Pass Expected date: Pass Expected date:

Fail completion

Fail completion

Pass Expected date:

Fail completion

Pass Expected date:

Fail completion

and

thunder-dense area, the angle should be within 30 . The cabling racks connecting 6.3C iron tower and equipment room should meet the design requirements. The lightning rod should be 6.4C connected to the ground grid by grounding cables. Pass Expected date: Pass Expected date: Fail completion Fail completion Pass Expected date: Pass Expected date: Fail completion Fail completion

Note: In areas where the days with thunderstorm are less than 20 each year, the BTS ground resistance can be
less than 10ohm or comply with the requirements of engineering design.

Confidential and Proprietary Information of ZTE CORPORATION.

ZXSDR BS8900 Environment Acceptance Report

For Internal Use Only

3. Acceptance Information Sheet (Required)


Site name: _______________

Item Bearing Capacity of Equipment Room

Data

Source of Data

Remarks

On-site measurement
kg/m
2

User

Accurate data is unavailable On-site measurement User

Ground Resistance

Accurate data is unavailable On-site measurement User

DC Voltage

Accurate data is unavailable On-site measurement User

AC Voltage

Accurate data is unavailable On-site measurement User

Protection Angle of Lightning Rod

Accurate data is unavailable

Confidential and Proprietary Information of ZTE CORPORATION.

ZXSDR BS8900 Environment Acceptance Report

For Internal Use Only

4. Acceptance Conclusion

Conclusion of the first acceptance


Conclusion of the second acceptance

Signed by ZTE representative: Date:

Signed by users representative: Date:

Signed by ZTE representative: Date:

Signed by users representative: Date:

Confidential and Proprietary Information of ZTE CORPORATION.

ZXSDR BS8900 Installation Acceptance Report

For Internal Use Only

ZXSDR BS8900 Outdoor Macro BTS Installation Acceptance Report


(2010-V1.0)

Contract No. Project Name Party A Date of Acceptance

HOT12090421 - 423 2G EQP #7 sumalirja 2012 ______________________ ________________

ZTE CORPORATION

Confidential and Proprietary Information of ZTE CORPORATION.

ZXSDR BS8900 Installation Acceptance Report

For Internal Use Only

Legal Information

All rights reserved. No part of this documentation may be excerpted, reproduced, translated, annotated or duplicated, in any form or by any means without the prior written permission of ZTE Corporation.

and are the registered trade marks of ZTE Corporation. The names and logos of ZTE products are proprietary logos or registered trade marks. The names of other products and companies mentioned in this manual may be proprietary to their owners respectively. Without the prior written permission of ZTE or the owners of third-party trade marks or trade names, this manual does not grant the reader any permission or right to use any marker appeared in the manual.

The product described herein conforms to the design requirements of environment protection and human security. The storage, usage, and discard of the product shall comply with the manual, related contract, or laws and regulations of related countries.

The actual product may differ from what is described in this standard due to frequent update of ZTE products and fast development of technologies. Please contact the local ZTE office for the latest updating information of the product.

For the latest document http://ecc.zte.com.cn

information,

please

visit

our

website:

Confidential and Proprietary Information of ZTE CORPORATION.

ZXSDR BS8900 Installation Acceptance Report

For Internal Use Only

Feedback Table
You are invited to give your suggestions and opinions to improve ZTE user manuals and enjoy better service by sending emails to zheng.junhua@zte.com.cn. Thank you for your cooperation!
Document Name Product Version No. Please provide your information for further contact: Name Post Code Tel Very Good General View Manpower information Equipment installation technique Cable troughs Cable layout and connection Cable Comments specifications Grounding requirements Outlook assembly Labels and others Work instruction Convenient consult Correct content Complete content Well-organized structure to and Company Address E-mail Good Ordinary Bad Very Bad ZXSDR BS8900 Installation Acceptance Report (2009-V1.0) Document Version No. V1.0

Confidential and Proprietary Information of ZTE CORPORATION.

ZXSDR BS8900 Installation Acceptance Report Straightforward expression

For Internal Use Only

You may give suggestions from any perspective such as the content, structure, details, depth, expression, figures/tables, special tools, FAQ and so on. The suggestions are not confined to this document.

Suggestions

Confidential and Proprietary Information of ZTE CORPORATION.

ZXSDR BS8900 Installation Acceptance Report

For Internal Use Only

Revision Records
Document Version No. V1.0 Prepared/ Revised by Liu Jiangning Prepared/Revi sed on 2009-5-30 Total Pages 16 Reason for Revision None Contents of Revision (Key Points Only) None

Note 1: This table must be completed before updating the archived document (the document archived in the archival room of the division or the Company). Note 2: Fill "None" in "Reason for Revision" and "Contents of Revision" when archiving this document for the first time.

Confidential and Proprietary Information of ZTE CORPORATION.

ZXSDR BS8900 Installation Acceptance Report

For Internal Use Only

1 Read Me
This installation acceptance report is compiled with reference to related standards of Ministry of Information Industry and in light of specific situations of the BS8900 base station. It is applicable to hardware installation acceptance for the BS8900 equipment. The items to be checked fall into two categories: Compulsory (C) and General (G). An item marked with (G) is a general item, namely the item shall be complied with if conditions permit. An item marked with (C) is a compulsory item, namely it must be complied with.

Confidential and Proprietary Information of ZTE CORPORATION.

ZXSDR BS8900 Installation Acceptance Report

For Internal Use Only

2 Participants in Installation Acceptance


User Date of commencement Person in charge: Users personnel Participants: Person in charge: ZTEs personnel Participants: Person in charge: Participants: Person in charge: Constructors personnel Participants: Project name Date completion of

Project supervisors personnel

Remarks

Confidential and Proprietary Information of ZTE CORPORATION.

ZXSDR BS8900 Installation Acceptance Report

For Internal Use Only

3 BTS Basic Information


Basic Information BTS Number BTS Name BTS Type BTS Configuration S1/1/1 S2/2/2 S3/3/3 S1/1 S2/2 S3/3 O1 O2 O3 Others: ______ Data Records

Confidential and Proprietary Information of ZTE CORPORATION.

ZXSDR BS8900 Installation Acceptance Report

For Internal Use Only

4 Items for Hardware Acceptance


4.1 Outdoor Installation Location of the Equipment
Item Content If the equipment is to be installed in the mountain slope or 1.1 G on the flat ground under the iron tower, then the simple fencing or shelter shall be built for the base station. 1.2 C A cement platform is required for the equipment installation to ensure that the equipment is more secure. If the soil resistivity of the site is lower than 700m, the ground resistance for the site should be less than 10 . 1.3 G Otherwise, the equivalent radius of the ground grid should be at least 20m, and horizontal radiating ground conductors that are 20~30m long should be laid at the four corners of the ground grid. Result Conclusion

Pass Fail Pass Fail Pass Fail

4.2 Equipment Installation Techniques


Item 2.1 C Content The equipment location shall meet the engineering design documents. The vertical deviation of the cabinets shall not exceed 1 of the cabinet height. After the cabinets are installed, they shall look neat. The 2.3 G same row and line of cabinets shall be on the same surface, with a deviation not more than 5mm allowed. Result Conclusion

2.2

Pass Fail Pass Fail Pass Fail

Confidential and Proprietary Information of ZTE CORPORATION.

ZXSDR BS8900 Installation Acceptance Report Item Content Before the cabinet is installed, a cement platform should be built at first. Then the cabinet is installed, with a certain maintenance space reserved. It is prohibited to install the expansion bolts directly on the building roof. (1) If two cabinets are piled, then the maintenance space should meet the following requirements: the left side, the right side and the rear side of the cabinets shall all have at 2.4 C least 300mm of space reserved, and the front side shall have at least 800mm of space reserved; (2) If two cabinets are in parallel, then the distance between them shall be at least 50mm and the cement platform shall meet the following requirements: the left side of the left cabinet, the right side of the right cabinet and the rear side of the two cabinets shall have at least 300mm of space reserved, and the front side shall have at least 800mm of space reserved. The shake-proof measures shall meet the engineering 2.5 C design requirements. And the accessories of shake-proof anchors shall be in complete set and be fixed correctly. 2.6 C The cabinet and the base are connected reliably. The cabinet shall not shake. Expansion bolts for the cabinet or base (support) shall be installed correctly and securely, and all the insulating 2.7 C washers, flat washers, spring washers, bolts and nuts shall be installed in the correct sequence, without reverse installation. 2.8 C If the insulating anchor is fixed, make sure the expansion bolts are insulated from the cabinet. All the fasteners shall be screwed down. All the parts of the cabinet shall not fall off or have damages. The connection shall not fall off or break. All the logos and labels shall be correct, complete and clear. After the cabinet is installed, it is required to clean its internal and external surfaces. Push the cover plates at the top and bottom cable holes to prevent small animals from entering.

For Internal Use Only Conclusion

Result

Pass Fail

Pass Fail Pass Fail Pass Fail Pass Fail Pass Fail Pass Fail Pass Fail Pass Fail Pass Fail

2.9

2.10 G 2.11 G 2.12 G

2.13 C

Confidential and Proprietary Information of ZTE CORPORATION.

ZXSDR BS8900 Installation Acceptance Report

For Internal Use Only

4.3 Installation of Outdoor Cable Trays


Item 3.1 3.2 C C Content The installation positions and heights shall comply with the engineering design requirements. The cable tray and the wall or the cabinet row shall keep parallel, with 2mm of horizontal deviation per meter allowed. The cable tray shall be level or plumb, and the specifications of the level irons shall be consistent. Both ends of the level 3.3 G iron shall be close to the flat steels of the tray and the level iron clips. The level irons and flat steels of the cable tray shall be perpendicular to each other. 3.4 G Components such as level iron clips and fastening bolts shall be in complete set and firmly fixed. The level irons of the cable tray shall be evenly spaced. If 3.5 G they obstruct cabling, the spaces can be adjusted appropriately. The troughs shall be installed in a straight, flat and secure 3.6 G way. The troughs in the same line shall be aligned, with 2mm of deviation allowed at the joints of two troughs. 3.7 3.8 C C The protection ground of the cable tray shall comply with the engineering design requirements. Reliable electric connection shall be ensured between the connected trays. The ground support poles of the cable trays shall be 3.9 G installed in a vertical and reliable way. The reinforcement support shall be installed stably and securely, with the hangers fixed neatly and vertically. The expansion bolts to fasten all supports shall have the 3.10 G same surplus length (about 5mm of bolt rod left outside the nut) after they are tightened. The indoor cable trays shall be grounded reliably. For the 3.11 G long cable trays, it is recommended to ground them once every 5 meters with multi-strand copper wire, whose cross sectional area is at least 16mm .
2

Result

Conclusion

Pass Fail Pass Fail Pass Fail Pass Fail Pass Fail Pass Fail Pass Fail Pass Fail Pass Fail Pass Fail Pass Fail

Confidential and Proprietary Information of ZTE CORPORATION.

ZXSDR BS8900 Installation Acceptance Report

For Internal Use Only

4.4 Cable Distribution and Connection


4.4.1 Cabling Requirements
Item Content Routes of the power cables, ground cables and signal cables shall 4.1.1 C satisfy the engineering design requirements and product installation requirements. Different kinds of cables shall be laid separately, with their routes 4.1.2 G clear, smooth, straight and without cross. Finally, the cables shall be bundled with proper tightness. 4.1.3 G 4.1.4 C 4.1.5 G 4.1.6 G The cables outside the cabinet shall not intertwist. And cables shall not bend in 360 in the cable tray. It is prohibited to suspend the cables in the air inside the cabinet. Cables and connectors in the cabinet that are redundant or for subsequent expansion must be placed in the base. The cable bending radius shall meet the related requirements. Result Conclusion

Pass Fail Pass Fail Pass Fail Pass Fail Pass Fail Pass Fail

4.4.2 Bundling Requirements


Item Content Cables must be bundled neatly and close to each other. The 4.2.1 G cable surface shall be the same level, either horizontally or vertically, with a deviation not more than 5mm allowed. 4.2.2 G To avoid core breaking, the ties shall be bond at the two sides near the bundle bend rather than at the bend. The tie specification is right. The larger the sectional area is, the longer and wider ties should be used (to sustain large 4.2.3 G pull forces). Avoid using the ties in serial connection. If the ties have to be used in serial connection, at most two ties can be connected. The cables shall not loosen in the ties. The cable ties shall face a consistent direction. The intervals between the ties shall be even and tidy (usually 300mm~1000mm). For the 4.2.4 G horizontal cable tray, the interval between two neighboring ties shall not exceed twice that between two neighboring crosspieces. For the vertical cable tray, the cables must be bundled to every crosspiece. Result Conclusion

Pass Fail Pass Fail Pass Fail

Pass Fail

Confidential and Proprietary Information of ZTE CORPORATION.

ZXSDR BS8900 Installation Acceptance Report

For Internal Use Only

Item

Content The surplus part of the tie shall be cut off. For the tie inside the cabinet, the surplus part shall be completely cut off from the buckle. For the tie outside the cabinet, the surplus part

Result

Conclusion

4.2.5 C

shall be neatly cut, with 2mm left from the buckle. It is prohibited to mix the black ties with the white ones. White ties shall be used inside the cabinet while black ties used outside the cabinet. Power cables, ground cables and signal cables shall be laid separately along the two sides of the cable tray. The cable surface shall be clean, without engineer marks. The insulating layers of protective tubes shall have no scratches or signs of damage.

Pass Fail

4.2.6 G

Pass Fail Pass Fail

4.2.7 G

4.4.3 Cable Connection


Item Content The cut ends shall be covered with proper tubes or wrapped with 4.3.1 C insulating tapes. The color of the tubes and tapes should be consistent with the cables (except the yellow-green PGN cables). For the same kinds of cables, the length of the cable cut ends shall 4.3.2 G be the same and so as the tubes and insulating tapes. The deviation shall not exceed 5mm. The welded cable shall not have open joints, false welding, missed welding, wrong welding or mixed welding. The core wires shall be 4.3.3 C close to the terminal. The joints shall have no sharp tips or lumps. The insulating layers of the core wires shall not be burnt. And the length of copper wires exposed in the air shall not exceed 2mm. 4.3.4 C 4.3.5 C 4.3.6 G All cables are connected properly, securely and neatly. It is prohibited to have wrong cable connections. When the cables are connected to the copper bar, the oxide layer of the copper bar at the grounding point shall be removed. If the cables are connected by screws, the screws shall be tightened. Result Conclusion

Pass Fail Pass Fail Pass Fail Pass Fail Pass Fail Pass Fail

4.4.4 Power Cables & Ground Cables


Item Content The routes of the cabinet input power cable and its protective 4.4.1 C ground cable shall comply with the requirements of the design documents. The routes of the power cable inside the cabinet shall meet the production installation requirements. Result Conclusion

Pass Fail

Confidential and Proprietary Information of ZTE CORPORATION.

ZXSDR BS8900 Installation Acceptance Report The cross sectional areas of the power cables and the ground cables shall comply with the product installation requirements. The 4.4.2 C cross sectional area of the ground cables shall be at least 35 mm
2 2

For Internal Use Only

and they shall be connected reliably to the indoor ground copper bar. And that of the DC power cable shall be at least 25mm and they shall be connected reliably. The cabinet input power cable shall be the 220V 3-cored single-phase cable or the 380V 4-cored 3-phase cable. The DC power cable inside the cabinet or between cabinets shall be the 2-cored outdoor interwoven shielding cable (16mm ) or the blue cable (16mm ). The -48V GND power cable shall be black, and the ground cable shall be yellow-green. Power cables and ground cables shall be made of whole-piece
2 2

Pass Fail

4.4.3 G

Pass Fail

4.4.4 C

multi-strand copper wires. There shall be no joint in the middle of a cable and its insulating layer shall be intact. The surplus parts shall be cut off rather than being coiled or bent repeatedly. The wiring terminals shall match the diameter of the power cables and the ground cables. The core wires shall be tidily trimmed. It is prohibited to cut off part of the core wires and connect the rest to small wiring terminals. Power cables and ground cables shall be clamped reliably, and the core in the terminal shall not be moveable. When the power cables are crimped and connected, each bolt can

Pass Fail

4.4.5 G

Pass Fail

4.4.6 C

support at most two wire terminals, and these two terminals shall cross over rather than overlap. The clamping part of the wiring terminal shall be covered with a

Pass Fail Pass Fail Pass Fail Pass Fail Pass Fail

4.4.7 G

hot-shrinkable tube or at least two layers of insulating tapes, without exposing the naked core or copper lug. The colors of the insulating tapes or the hot-shrinkable tubes shall be consistent with the cables. The 48V power cable shall be

4.4.8 C

wrapped with blue tapes, the -48V GND power cable shall be wrapped with black tapes and the ground cables shall be wrapped with yellow tapes. The ground cable of the cabinet door shall be connected securely. It shall be complete and shall not fall off. The outdoor copper ground bar shall have a special reliable path to the underground ground grid, and the path shall be as short as possible.

4.4.9 G

4.4.10 C

4.4.5 Optical Fibers and Trunk Cables


Item Content Result Conclusion

Confidential and Proprietary Information of ZTE CORPORATION.

ZXSDR BS8900 Installation Acceptance Report When the optical fibers are distributed via the fiber distribution box, 4.5.1 C the end of the tail fiber protection tube shall not be more than 0.5m away from the fiber distribution box. The cable ties to fasten the tail fibers inside the cabinet shall be 4.5.2 C nylon adhibit ties. And the tail fibers shall be able to be drawn freely in the cable ties. The optical fibers shall be laid straightly. There shall be no other 4.5.3 G cables on their top. And they shall be kept from the sharp edges of other objects. 4.5.4 G The optical fibers shall enter the cabinet from the left side at the bottom of the cabinet. The cut end of the protection tube shall be neat without burrs. The 4.5.5 G joint between two tubes shall be wrapped with electrical insulating tapes to avoid damages to the tail fibers. 4.5.6 G 4.5.7 G 4.5.8 G The excessive optical fibers shall be coiled inside the tail fiber box, or coiled with a diameter over 80mm and then fixed. The idle optical connectors shall be covered by protective tubes. The cut end of the trunk cable shall not hurt the core wires. The welding joints of the trunk cables shall not have open joints, false welding, missing welding, wrong welding, or mixed welding. 4.5.9 C The cores shall closely fit with the terminals. The welding point shall not have sharp edge or lump, and the insulation layer of the cable shall not be burned during welding. The exposed copper wires shall not be longer than 2mm. The reserved cables on the back of the DDF and ODF terminal 4.5.10 G plates shall be neat with consistent radian and length. The length of the reserved cables shall ensure that the terminal plates can be freely turned in debugging.

For Internal Use Only

Pass Fail Pass Fail Pass Fail Pass Fail Pass Fail Pass Fail Pass Fail Pass Fail Pass Fail

Pass Fail

4.5 Antenna Feeder System


Item Content Result Planned antenna height: The actual mount height of the antennas shall be consistent with the network plan and their installation positions shall 5.1 C accord with the engineering design requirements. The antenna height means the height between the ground and the mid-point of the antenna. :_______ m :_______ m :_______ m Actual height: :_______ m :_______ m : _______ m antenna Conclusion

Pass Fail

Confidential and Proprietary Information of ZTE CORPORATION.

10

ZXSDR BS8900 Installation Acceptance Report

For Internal Use Only

Item

Content

Result Planned antenna azimuth: :_________ :_________ :_________ Actual azimuth: :_________ :_________ :_________ Planned mechanical down-tilt angle: :_________ :_________ :_________ Actual mechanical down-tilt angle: :_________ :_________ :_________ Planned electrical antenna

Conclusion

Measure the azimuth: the actual antenna azimuth shall 5.2 C comply with the network plan. And the azimuth deviation of the directional antenna shall be within 5.

Pass Fail

Measure the mechanical down-tilt angle of the antenna with an angle meter: the actual mechanical down-tilt angle shall 5.3 C comply with the network plan. And down-tilt angle deviation of the directional antenna shall be within 0.5. This item is not required for the omnidirectional antenna.

Pass Fail

For a pointer electrically regulated antenna, regulate it with a wrench; and for a digitally controlled and electrically regulated antenna, control it via a keyboard in the 5.4 C equipment room, but the control wire is easy to break. If the control wire breaks, it is necessary to directly regulate it with a wrench. The actual down-tilt angle shall comply with the network plan. And this item is not required for the non-electrically-regulated antenna. Master and diversity antennas in all the sectors should 5.5 C correspond to the proper cabinet jumpers in a one-to-one manner.

down-tilt angle: :_________ :_________ :_________ Actual electrical down-tilt angle: :_________ :_________ :_________

Pass Fail

Pass Fail
VSWR: ANT1:________ ANT2:________ ANT3:________ ANT4:________ ANT5:________ ANT6:________

5.6 C

The VSWR of the antenna feeder system shall be less than 1.5.

Pass Fail

Confidential and Proprietary Information of ZTE CORPORATION.

11

ZXSDR BS8900 Installation Acceptance Report

For Internal Use Only

Item

Content Both ends of the feeder shall bear feeder tags and both tags

Result

Conclusion

5.7 C

shall be consistent to ensure the feeder shall correspond to the proper antenna. Specification the feeder: of

Pass Fail Pass Fail

5.8 C

The feeder specification shall comply with the design.

:_________ m :_________ m :_________ m Planned antenna model: :_________ :_________

5.9 C

The models of applied antennas shall comply with the network plan.

:_________ Planned antenna model: :_________ :_________ :_________

Pass Fail

The antennas shall be installed below the lightning rod and 5.10 C within its protective range. The protective angle in the plains shall not be more than 45 and in the mountains not more than 30. The supporting rods of all antennas shall be securely installed and shall not shake. It shall satisfy the wind 5.11 C resistance requirements. The masts used for roof installation shall be grounded and fall within the effective lightning protection range. 5.12 C 5.13 C All antenna masts shall be installed steadily, well grounded and vertical to the ground with a vertical error less than 2. The diversity distance between two dual-polarization antennas of different sections shall be at least 300mm. The horizontal and vertical isolation of the GSM BTS and 5.14 C the other types of base station antennas shall comply with the network design requirements. 5.15 C The omni-antenna shall maintain the uprightness with the error less than 2. The distance from the omnidirectional antenna to the tower 5.16 C body shall not be less than 1.5m, and that from the directional antenna to the tower body no less than 1m. 5.17 C For the omni-antenna, the top of the jacket shall be as high as or higher than the top of the antenna bracket.

Pass Fail

Pass Fail Pass Fail Pass Fail Pass Fail Pass Fail Pass Fail Pass Fail

Confidential and Proprietary Information of ZTE CORPORATION.

12

ZXSDR BS8900 Installation Acceptance Report

For Internal Use Only

Item

Content When an omnidirectional antenna is mounted on the roof, it

Result

Conclusion

5.18 C

shall fall within the 45 protection range of the lightning rod and its horizontal distance to the lightning rod shall be at least 2.5m. The horizontal distance between the receiving antenna and the transmitting antenna shall be at least 3.5m. If the soil resistivity of the site is lower than 700m, the ground resistance for the site should be less than 10. Otherwise, the equivalent radius of the ground grid should be at least 20m, and horizontal radiant ground conductors that are 20~30m long should be laid at the four corners of the ground grid. The route must be correct and comply with the engineering design requirements. The bends of feeders must be round and smooth, with a bending radius at least 20 times the outer diameter of the feeder (the bending radius of a soft feeder shall be at least 10 times the outer diameter of the feeder). The feeders shall not be bent repeatedly. If the length of a feeder 20m, then ground it at two points, one within 2m from the antenna feeder connector and the other which is within 2m from the cabinet bottom cable inlet and connected to the outdoor ground bar; If 20m < its length 60m, add a ground point with 2m from the point where it leaves the iron tower or the rooftop; If its length >60m, it is required to add one more ground point for every 20 more meters. The oxidization layer of the grounding point shall be removed first before the outdoor feeder is grounded. Each grounding terminal shall be separately connected and fastened. If the feeder is not long enough, it shall never be joined with another feeder to form a longer one. In addition, the grounding terminals shall have anti-corrosion treatment. When the outdoor feeder grounding cables are routed from the top down (vertically), their included angle with the feeders shall be preferably no more than 15 and they must be well grounded with the grounding copper bars or towers.

Pass Fail Pass Fail Pass Fail

5.19 C

5.20 G

5.21 C

Pass Fail

5.22 C

Pass Fail

5.23 C

Pass Fail

5.24 G

If the tower has no grounding copper bar, connect the feeder ground terminals and the amplifier ground terminals separately with the tower body. Each grounding point shall have at most 2 ground terminals and have sound electric connection.

Pass Fail

Confidential and Proprietary Information of ZTE CORPORATION.

13

ZXSDR BS8900 Installation Acceptance Report

For Internal Use Only

Item

Content All connectors between outdoor antenna and feeder,

Result

Conclusion

5.25 C

between jumper and feeder, and ground points between feeder and grounding cable clip shall all have the waterproof treatment. Connectors between antenna and feeder, between jumper and feeder, and ground points between feeder and grounding cable clip shall all have the waterproof treatment: they shall be wrapped in the mode of 1 layer of P VC insulating tape 3 layers of waterproof adhibit adhesive tape 3 layers of PVC insulating tape". The waterproof adhibit adhesive tape shall be stretched with proper strength to make its width shrink to 75%~50% of the original width. And the antenna-feeder connector should be wrapped from the bottom up. After the connectors are wrapped securely, both ends shall be bond with black ties. Note: The wrapping direction should be the same as the connector screwing direction. It is prohibited to wrap the tape in the reverse direction. The outdoor jumpers shall be bond along the horizontal rails of the brackets to the supporting rods. At the joint between the jumper and antenna, the jumper shall keep 300mm straight (antenna port is in the back).

Pass Fail

5.26 C

Pass Fail

5.27 G 5.28 G

5.29 C 5.30 C

The feeders shall be connected correctly to the correct sectors. The feeder connectors are prepared and made correctly. And they shall not loosen. It is recommended to use trinity clips to fix the feeders. The interval between every two adjacent clips shall not exceed 1m. After the cabling, the intervals shall be consistent, and the clips shall be unmovable and in the uniform direction. After the feeders enter the cabinet, push the cover plates at

Pass Fail Pass Fail Pass Fail Pass Fail Pass Fail Pass Fail Pass Fail Pass Fail

5.31 G

5.32 G

the bottom cable holes to prevent small animals from entering.

5.33 C 5.34 G

There are no obvious breaks or distortions in the feeders, and the copper of the feeders shall not be exposed. The feeders shall not intertwist. They shall be laid neatly and straight, with the same curvature.

Confidential and Proprietary Information of ZTE CORPORATION.

14

ZXSDR BS8900 Installation Acceptance Report

For Internal Use Only

4.6 Assembly, Labels and Others


4.6.1 Assembly
Item Content The cabinet and its door shall not be seriously damaged or 6.1.1 G deformed and they shall be free of scratches or paint fall-off. The places where the paint has fallen off shall be re-painted in the same color. 6.1.2 G At least one antistatic wrist strap shall be equipped in each cabinet. The ESD jacks must be installed firmly. The air intakes and outtakes of the fans shall not be blocked. The cabinets shall not be used to store sundries such as tools or 6.1.4 G spare parts. There shall be no redundant or waste engineering materials such as cable ties or bolts inside the cabinets. 6.1.5 G There shall be no obvious dust inside the cabinets and on the floor beneath the cabinets. All dummy extractors and the blank filler panels should be installed. The connectors shall all be securely connected, the bolts fixing the 6.1.7 G boards shall all be tightened, and the fastening clips shall be in position and not damaged. 6.1.8 G 6.1.9 G Protection caps shall be applied to the idle optical interfaces and sockets. The cable holes in the cabinet shall be well protected and sealed. Result Conclusion

Pass Fail Pass Fail Pass Fail Pass Fail Pass Fail Pass Fail Pass Fail Pass Fail Pass Fail Pass Fail Pass Fail Pass Fail

6.1.3 G

6.1.6 G

6.1.10 G 6.1.11 G 6.1.12 G

The cabinet door can be opened and closed smoothly. The cabinet surfaces shall all be clean. All the fixing bolts shall be screwed tightly.

Confidential and Proprietary Information of ZTE CORPORATION.

15

ZXSDR BS8900 Installation Acceptance Report

For Internal Use Only

4.6.2 Labels
Item Content The power cable breakers for the ZTE equipment in the power 6.2.1 G cabinet and power distribution box shall bear labels indicating the cable directions. 6.2.2 G The labels for the above breakers shall be pasted tidily. Both ends for all cables must bear labels. The labels inside the 6.2.3 G cabinet shall be standard ZTE private pasters and the labels outside the cabinet shall be ZTE plastic tags. The feeder labels shall be outdoor tags. They shall be one for the antenna feeder, three for the outdoor feeders (one point near the 6.2.4 G antenna feeder connector, one near the cabinet inlet before the feeder enters the cabinet, and one before it leaves the iron tower or rooftop), and one near the rack-top jumper. 6.2.5 G The feeder shall be labeled, with the label 200mm away from the connector. The cables in the cabinet shall be labeled at consistent positions. 6.2.6 G The power cables, ground cables, transmission cables and optical fibers shall be labeled, with the labels 20mm away from the cable ends. No label should be pasted and no mark should be written on the 6.2.7 G board. If it is required, the handwriting should be neat and the labels should be pasted tidily. The label should mark out the equipment name (number) and the 6.2.8 G interface position as detailed as possible, such as Equipment name (number) Interface No. It is prohibited to use simple numbers to mark the labels. The labels shall be pasted in the same direction, with the side 6.2.9 G indicating the cable directions upward or facing the maintenance and operation planes for the convenience of reading. Result Conclusion

Pass Fail Pass Fail Pass Fail Pass Fail Pass Fail Pass Fail Pass Fail Pass Fail Pass Fail

4.6.3 Others
Item 6.3.1 G Content All the installation tools shall meet the antistatic requirements. The board unpacking and plugging/unplugging shall meet the antistatic operational requirements. Result Conclusion

Pass Fail Pass Fail

6.3.2 G

Confidential and Proprietary Information of ZTE CORPORATION.

16

ZXSDR BS8900 Installation Acceptance Report

For Internal Use Only

Item

Content To facilitate subsequent expansions, signal cables that are

Result

Conclusion

6.3.3 G

delivered for expansions shall be bond or placed in the to-be-expanded cabinet.

Pass Fail Pass Fail Pass Fail Pass Fail

6.3.4 G

Protective measures shall be taken for the idle plugs. For example, the protective caps can be used. The equipment room shall be clean and tidy. The useless packing

6.3.5 G

boxes shall be removed. And the spare parts shall be placed in order.

6.3.6 G

The specification of the fuse shall comply with the nominal capacity.

Confidential and Proprietary Information of ZTE CORPORATION.

17

ZXSDR BS8900 Installation Acceptance Report

For Internal Use Only

5 Acceptance Conclusion

Users comments

Signature:

Date:

ZTEs comments

Signature:

Date:

Project supervisors comments

Signature:

Date:

Constructors comments

Signature:

Date: