You are on page 1of 7

Our policy is one of continuous development.

Accordingly the design of our products may change at any tim Whilst every effort is made to produce up to date literature, this document should only be regarded as a guid is intended for information purposes only. Its contents do not constitute an offer for sale or advice on the application of any product referred to in it. W cannot be held responsible for any reliance on any decisions taken on its contents without specific advice

products may change at any time. uld only be regarded as a guide and

f any product referred to in it. We contents without specific advice.

CORTEC

Ordering information
Variants Order No. Voltage Operated Attracted Armature Auxiliary Relay with Hand Reset Contacts Case Historical Record Purpose Only - Size 2 Case (Alstom Livery) Historical Record Purpose Only - Size 4 Case (Alstom Livery) Size 2 AREVA Livery (Grey/Grey) Size 4 AREVA Livery (Grey/Grey) Operation Indicator (Flag) By Contact Type Standard Contact No Flag With Flag BOM Contact No Flag With Flag Time Function Standard Time High Speed Relay to Operate in less than 10 Milliseconds Voltage & Contact Combinations Voltage Options 24 to 27 Vac/Vdc 30 to 34 Vac to Vdc 48 to 54 Vac to Vdc 110 to 125 Vac to Vdc 220 to 250 Vac to Vdc Plus Contact Configuration Options 1 Standard Contact plus 3 Heavy Duty Contacts MVAA13 J L R T 1

A B J K

1)

A C

0 0 0 0 1

0 2 5 7 0

0 5 0 5 0

0 0 0 0 0

0 1 0 1 to 0 1 0 8 0 1 3 1 to 0 1 3 4 0 1 7 6 to 0 1 9 6 0 2 2 1 to 0 2 3 4 0 1 0 9 to 0 1 2 0 0 1 3 5 to 0 1 4 3 0 0 1 6 0 0 2 2 0 1 5 1 to 0 1 7 5 0 2 0 1 to 0 2 2 0 0 0 3 1 to 0 0 5 1 0 0 5 3 to 0 0 6 9 C A

1 Standard Contact plus 3 Heavy Duty Contacts with Cut Out Contact

2 Standard Contacts plus 6 Heavy Duty Contacts

2 Standard Contacts plus 6 Heavy Duty Contacts with Cut Out Contact

3 Standard Contacts plus 2 Heavy Duty Contacts

3 Standard Contacts plus 2 Heavy Duty Contacts with Cut Out Contact

4 Standard Contacts - 4 Break Before Make 4 Standard Contacts - 4 Break Before Make with Cut Out Contact 4 Standard Contacts plus 4 Heavy Duty Contacts

4 Standard Contacts plus 4 Heavy Duty Contacts with Cut Out Contact

6 Standard Contacts with or without Cut Out Contact

8 Standard Contacts with or without Cut Out Contact Issue Housed in a size 2 Case Housed in a size 4 Case

Note 1) : High speed option temporarily withdrawn pending further investigations EXCEPT for variants : MVAA13R1AC0281C, MVAA13R1AC0781C, MVAA13R1BC0281C and MVAA21R1BC0781C

Page 3

211999236.xlsx.ms_office

2/18/2014

211999236.xlsx.ms_office Configurator

Voltage Operated Attracted Armature Auxiliary Relay with Hand Reset Contacts MVAA13
1-6 7 8 9 10 11 14 15

MVAA13
Case Size

R R K

1 K A

0101

Housed in a Size 2 Case


Operation Indicator (Flag) Time Function

A
Auxiliary Voltage, Vx

0000
Number of Standard Contacts
plus

0100
Contact Combination, Standard Contacts
plus

0101 0001

Number of Heavy Duty Contacts


3 Heavy Duty Contacts plus

Contact Combination, Heavy Duty Contacts

0000
Issue Factory Defined

Page 4

211999236.xlsx.ms_office

2/18/2014

Master Text

MVAA13R1KA0101C
SINGLE ELEMENT ATTRACTED ARMATURE AUXILIARY RELAY HAND RESET CONTACTS INCLUDING HEAVY DUTY WITH HAND RESET FLAG INDICATOR, WITH OR WITHOUT CUT OFF CONTACT HOUSED IN A SIZE 2 CASE Auxiliary Supply Voltage : 24 to 27 Vac/Vdc Standard Output Contacts : 1-Make Standard Contact PLUS 3-Make BOM Contacts Documents Outline Wrapper Customer Wiring Diagram : GJ0025.SHEET.1 : 01MVAA1324 SHT 1

Issue Version :

A Original - 17/06/2003 B Header Text, ie. Lines 5 to 8 added to Master Text sheet - 12/01/04 Retrospective amandments of Date Drivers, Database & BOM to C include Areva livery - 02/05/07 Time Function "C" temporarily withdrawn per CIDs NJOH-75XDNY, NJOH-76HD82, NJOH-76RDJP and NJOH-779BYL except for variants MVAA13R1AC0781C and MVAA13R1BC0781C - 25/09/07 Aux Units database text corrected for FB0307003.76 (coil was E ZC0228016 in error) - 09/10/07 Database amended to allow variants MVAA13R1AC0281C and F MVAA13R1BC0281C per CID NJOH-77UEHH - 12/10/07 BOM retrospectively corrected to differentiate between 01/2MVAA13 G 008 Sht1/2 - 11/05/08 D H FB0307013.02 added to Aux Units for MVAA13T1AA0307A - 18/07/08 Aux Units corrected for some 6 & 8 contact variants (unit was I FB0307003 in error) 17/09/08

Page 5

211999236.xlsx.ms_office

2/18/2014

BOM

PCS MATERIAL MASTER MVAA13R1KA0101C

NUMBER

DESCRIPTION

GJ0013003 GJ9179101AREVA GJ0414103AREVA GJ0428036AREVA GJ0010119AREVA ZB4018118 ZJ0254001 ZA0005106 ZA0005059 02MVAA1324 SHT 1 FB0307008.??? Aux Unit Coil Contacts

TERMINAL BLOCK ASSY MODULE PRINTED LABEL ASSY CASE MIDOS SIZE 2 (BLUE) ASSY COVER AND RESET ASSEMBLY MODULE SIZE 2 SELF TAPPING SCREW SIZE 4 X 1/4" LG ASSY PCB - COST-IMP'D MVAA/MVAJ - A/03 MIDOS MTG PACK (4X) ZA0005059 (12 PACK) INT WIRING DIAGRAM See Below FB0307008 ZC0228018 FB0316056

Page 6 of 7

211999236.xlsx.ms_office

2/18/2014

BOM

Qty. Required 1 1 1 1 1 10 1 1 1 1 1 1 1 1

Page 7 of 7

211999236.xlsx.ms_office

2/18/2014

You might also like