SOLAR PV POWER PLANT

SECTION-D TECH. PARTICULARS (TO BE FILLED BY THE TENDERER)

Sl. No. I 1 2 3 4 5 6 7 8 9 10 11 II 1 2 3 4 5 6 III 1 2 3 4 5 6 7

Description SOLAR PV PLANT Capacity Type of SPV module Rating of SPV module PCU(inverters) rating SCADA for diagonising and monitoring Schematics and layout drawings. No. Of modules per MW Array rating HT Transformer rating Area required Guaranteed annual energy genertion from 5mw plant TECHNICAL DETAILS OF PROJECT Meteorological parameters for the site. Height above seal level Solar radiation Temperature PV module Type Technology used TECHNICAL DETAILS OF PV MODULE - Technical Specifications of PV modules - PV module power output at STC - Dimensions of single module - Total no. of Module to be used - Total PV array capacity - Details of series / parallel combination - Out put of the PV array (s) to be connected to the PCU

To be furnished by the bidder

IV 1 2 3 4 5 6 7 8 9

MOUNTING STRUCTURE Type Material Overall dimensions Coating Wind speed rating Tilt angle Foundation Number of Module structure Fixing type
Page 1 of 72

CE(GSW)/SPV/BELAKAVADI

SOLAR PV POWER PLANT

SECTION-D TECH. PARTICULARS (TO BE FILLED BY THE TENDERER)

Sl. No.

Description

To be furnished by the bidder

Page 2 of 72

CE(GSW)/SPV/BELAKAVADI

SOLAR PV POWER PLANT

SECTION-D TECH. PARTICULARS (TO BE FILLED BY THE TENDERER)

Sl. No. V 1 2 3 4 6 7 8 9 10 11 12 13 14 VI 1 2 3 4 5 6 a b 7 8 9 10 11 a b c 12 a b 13 a b c d 14 a

Description INVERTER Input Data Max PV power (recommended) DC voltage range MPPT Max permissible DC voltage Max permissible DC current Output Data Nominal Ac power Operating voltage grid -20% TO 15% Utility type Operating frequency grid Voltage ripple PV voltage Phase shift Efficiency 1250 KVA TRANSFORMERS Manufacturer Transformer application/designation Quantity Full load rating KVA Number of Phases Rated No-load voltages HV LV Type of cooling Rated percentage impedance Rated frequency Hz Installation Outdoor/Indoor Winding connection HV LV Vector group Highest system voltage for which transformers are suitable HV LV Tapping on winding Off load taps Total tappings range Tapping steps On HV windings Maximum temperature rise of Oil by thermometer

To be furnished by the bidder

PPV UPC UPC max lPC max PAC UAC IAC UPP Cos j

: : : : : : : : : : : : : : : : : : : : :

: deg.

Page 3 of 72

CE(GSW)/SPV/BELAKAVADI

SOLAR PV POWER PLANT

SECTION-D TECH. PARTICULARS (TO BE FILLED BY THE TENDERER)

Sl. No.

Description b Winding by resistance method 15 Guaranteed Losses

To be furnished by the bidder : deg.

Page 4 of 72

CE(GSW)/SPV/BELAKAVADI

SOLAR PV POWER PLANT

SECTION-D TECH. PARTICULARS (TO BE FILLED BY THE TENDERER)

Sl. No. 16

17

18 19 a b c d e 20

Description Load loss at rated current at 75 deg. C winding temperature (guaranteed subject to + tolerance as per applicable standards) No-load losses ( core loss and dielectric loss ) at 100% rated voltage and frequency subject to + tolerance as per applicable standards) Magnetic current at rated voltage and frequency: in percent of full load current Weight Winding Core Oil Tank, coolers and fittings Total ( a to d ) Efficiency at 75 deg. C Full Load, U.P.F

To be furnished by the bidder KW

KW

Kg Kg Kg Kg % Maximum flux density

a At rated voltage b At 110% of rated voltage VII 1 2 3 4 5 6 7 8 (NEUTRAL GROUNDING RESISTORS) Manufacturer Resistor Material Outdoor/Indoor Type of Enclosure Rated Continuous Current Rated Ohmic Value Resistor Taps Maximum current carrying capacity for 60 secs 9 Rated Voltage 10 Insulation Grade 11 Rated Power 12 Temperature rise ( not exceeding safe temperature of insulation), when carrying a Maximum current for 60 Secs b Continuous rated current 13 Change in resistance with temperature Rise of 100 deg. a Off load taps 14 Voltage class of stand insulators 15 List of tests to be carried out 16 Applicable Standard

Wb/m2 Wb/m2

: : : : : : :

: :

: :

Page 5 of 72

CE(GSW)/SPV/BELAKAVADI

SOLAR PV POWER PLANT

SECTION-D TECH. PARTICULARS (TO BE FILLED BY THE TENDERER)

Sl. No. 17

Description Total Weight

To be furnished by the bidder

Page 6 of 72

CE(GSW)/SPV/BELAKAVADI

SOLAR PV POWER PLANT

SECTION-D TECH. PARTICULARS (TO BE FILLED BY THE TENDERER)

Sl. No. VIII 1 2 3 4 5 6 7 8 9 10 a) b) c) d) e) f) g) h) i)

j) k)

l) 11 a)

Description 11KV SWITCHGEAR CUBICLE System particulars Normal system voltage Corresponding highest system voltage Frequency Number of phases Neutral earthing Class indoor/outdoor Rated short circuit withstand of the panels Switchgear type Circuit breaker parameters Type Number of poles Rated voltage Rated normal current Rated frequency Rated short circuit breaking current Rated short time withstand current Rated Operating Duty Rated insulation level i) Rated/min power frequency withstand voltage (rms value) ii) Rated lightning impulse withstand voltage (peak value) Rated duration of short circuit Rated supply voltage for closing and opening devices and auxiliary circuitsClass indoor/outdoor No. of Auxiliary Contacts Current transformers Rated Insulation level i) Rated/min power frequency withstand voltage (rms value) ii) Rated lightning impulse withstand voltage (peak value) Class of insulation Instrument Safety Factor(ISF) Minimum creepage system voltage C.T. details Ratio - Primary -Secondary

To be furnished by the bidder

b) c) d) e) f) g)

Page 7 of 72

CE(GSW)/SPV/BELAKAVADI

SOLAR PV POWER PLANT

SECTION-D TECH. PARTICULARS (TO BE FILLED BY THE TENDERER)

Sl. No.

Description h) Class of Accuracy i) Core I ii) Core II

To be furnished by the bidder

Page 8 of 72

CE(GSW)/SPV/BELAKAVADI

SOLAR PV POWER PLANT

SECTION-D TECH. PARTICULARS (TO BE FILLED BY THE TENDERER)

Sl. No.

Description To be furnished by the bidder i) Purpose of each core i) Core I ii) Core II j) Burden i) Core I ii) Core II Note: CTs shall be of reputed make with proven experience. Potential transformers/voltage transformers Rated Insulation level. i) Rated/min power frequency withstand voltage (rms value) ii) Rated lightening impulse withstand voltage (peak value) Class of insulation Rated voltage factor Clear height of bushing Minimum creepage distance Applicable standard IS: 3156 PT details Rating Burden Class of Accuracy Purpose Connection Note: Potential transformers shall be single phase units. PTs shall be of reputed make with proven experience. Each secondary shall be protected by 3 Details of auxiliary supply for operation/control, protection, alarm, indication etc. DC supply AC supply FEEDER DETAILS Incoming feeders Current rating Outgoing feeder Current rating Spare feeders ---------------------nos amps nos amps amps

11 a)

b) c) d) e) f) 1 2 3 4 5

12

i) ii) 13

Page 9 of 72

CE(GSW)/SPV/BELAKAVADI

SOLAR PV POWER PLANT

SECTION-D TECH. PARTICULARS (TO BE FILLED BY THE TENDERER)

Sl. No. IX

X XI XII

Description D.C. BATTERY BANK DETAILS Make Main capacity Stand by capacity Ampere hours Battery Charger details 10 KW SOLAR PV ROOF TOP DETAILS ILLUMINATION SYSTEM FIRE FIGHTING SYSTEM AIR CONDITIONER SYSTEM

To be furnished by the bidder --------- VOLTS ------ VOLTS ----- each

: :

XIII XIV 1 2 3 4 5

COMMUNICATION SYSTEM 6300 KVA TRANSFORMER Name of the manufacturer Type of service (indoor/outdoor) Applicable standards No-load voltage ratio (guaranteed) Guaranteed continuous rating for the specified cooling, temperature rise over the ambient temperature (KVA)(With spare cooler cut-off) Guaranteed continuous overload rating (KVA) (With spare radiator in service) Rated voltage HV (kV) LV (kV) Rated frequency (Hz) No. of phases Current at rated voltage & on principal tap HV (Amps) LV (Amps) Vector group reference and symbol Guaranteed rated temperature rise above reference peak ambient temperature of air (C) Top oil by thermometer of winding by resistance by Hot spot temperature indicator for which the transformer is designed

6 7 i) ii) 8 9 10 i) ii) 11 12

a. b. c.

Page 10 of 72

CE(GSW)/SPV/BELAKAVADI

SOLAR PV POWER PLANT

SECTION-D TECH. PARTICULARS (TO BE FILLED BY THE TENDERER)

Sl. No. Description To be furnished by the bidder 13 i) Guaranteed No-load losses at rated voltage & frequency at principal tap (KW) (without tolerance) ii) No-load losses at the voltage corresponding to the highest tap (KW) No-load loss 14 a. At 90% rated voltage (KW) b. At 100% rated voltage (KW) c. At 110% rated voltage (KW) 15 i) Guaranteed load losses(KW) at rated output, rated frequency and at 75C average winding temperature at principal tap(without tolerance) ii) Load losses at rated output, rated frequency and at 75C average winding temperature at a. Highest tap b. Lowest tap Guaranteed total losses(KW) at normal 16 ratio, rated output, rated voltage and rated frequency and at 75C (without tolerance) Positive sequence impedance on rated 17 MVA base at rated current & frequency at 75oC winding temperature at: i) Principal tap(%) ii) Highest tap(%) iii) Lowest tap(%) 18 Zero Sequence impedence at 750 C i) Principal tap (%) ii) Highest tap (%) iii) Lowest tap (%) 19 Resistance voltage drop at 750 C average winding temperature and rated full load expressed as percentage of rated MVA(All values to be referred to primary) i) H.V(%) ii) L.V(%) 20 Reactance voltage drop at 750 C and full load between windings expressed as % of rated voltage between H.V & L.V (%)

Page 11 of 72

CE(GSW)/SPV/BELAKAVADI

SOLAR PV POWER PLANT

SECTION-D TECH. PARTICULARS (TO BE FILLED BY THE TENDERER)

Sl. No. 21

22 i) ii) 23 a. b. 24

i) ii) 25

i) ii) iii) iv) 26 i) ii) 27 28 29 i) ii) iii) 30 31 32 i) ii) iii)

Description To be furnished by the bidder Guaranteed impedance voltage at normal tap and at 75 C average winding temperature expressed as percentage of rated voltage (%) Impedance per phase Referred to H.V side (Ohms) Referred to L.V side (Ohms) Test voltages Lightning Impulse withstand(kV) Peak Power Frequency voltage withstand(kV) Peak Regulation at full load & 75 C winding temperature expressed as a % of normal voltage @ Unity P.F @ 0.8 P.F(lagging) Efficiencies at normal ratio, rated voltage, rated frequency and 75 deg. cen. average winding temperature for the output at unity p.f. & 0.8 p.f. corresponding to: 100 % Load 75 % Load 50 % Load 25 % Load Maximum efficiency(%) Load at which maximum efficiency occurs (% of full load) Permissible overloading Insulating & cooling medium Terminal arrangement HV side LV side Neutral Noise level when energised at normal voltage and frequency without load(db) External short circuit withstand capacity (MVA) & duration(secs.) Overflux withstand capability of the transformer corresponding to: Factor 1.1 Factor 1.25 Factor 1.4

Page 12 of 72

CE(GSW)/SPV/BELAKAVADI

SOLAR PV POWER PLANT

SECTION-D TECH. PARTICULARS (TO BE FILLED BY THE TENDERER)

Sl. No. 33

Description Ideal heating time or thermal time constant (Hours)

To be furnished by the bidder

Page 13 of 72

CE(GSW)/SPV/BELAKAVADI

SOLAR PV POWER PLANT

SECTION-D TECH. PARTICULARS (TO BE FILLED BY THE TENDERER)

Sl. No. 1 i) ii) iii) a) b) iv)

a) b) v) a) b) c) vi) vii) a) b) c) d) e) f) g) h) viii) a) b) c) ix) x) xi)

Description To be furnished by the bidder ADDITIONAL TECHNICAL PARTICULARS Details of core Type of core construction Type of joint between core limb & yoke Maximum flux density at rated voltage & frequency and at principal tap Core (weber/sq.mtrs) Yoke (weber/sq.mtrs) Max. flux density in iron at voltage and frequency 10% higher than normal (webers/sq.mtrs.) Core Yoke Magnetising current at normal ratio & frequency 90% of rated voltage 100% of rated voltage 110% of rated voltage power factor of magnetising current at normal voltage, ratio & frequency Material of core lamination and grade Thickness of core lamination Insulation between core lamination Insulation of core bolts Insulation of core bolt washers Core bolt insulation withstand voltage for 1 minute(kV rms) Are the core bolts grounded. If so how Area of cross section of core lamination. Material of core clamping plate Thickness of core clamping plate Insulation of core clamping plate Describe location/method of core grounding Details of oil ducts in core Exciting va/kg or w/kg of lamination material at i) 15,000 gauss ii) Rated induction (vide item iii(a)) iii) Induction as per item (iv)

Page 14 of 72

CE(GSW)/SPV/BELAKAVADI

SOLAR PV POWER PLANT

SECTION-D TECH. PARTICULARS (TO BE FILLED BY THE TENDERER)

Sl. No. 2 i) a) b) ii) a) b) iii) a) b) iv) v) a) b) vi) vii) viii) ix)

x) a) b) xi) a) b) xii) a) b) xiii) a) b) xiv) xv) a) b)

Description To be furnished by the bidder DETAILS OF WINDINGS: Type of Winding HV winding LV winding Material of the winding conductor HV winding LV winding Maximum current density of windings and conductor area (at rated current) Current density(A/cm2) HV winding LV winding Conductor area(cm2) HV winding LV winding Type of joints in the windings Resistance of (Approx) HV winding(ohms/ph) LV winding(ohms/ph) Whether HV windings are interleaved Whether windings are preshrunk Whether adjustable coil clamps are provided for HV & LV windings Whether electrostatic shields are provided to obtain uniform voltage distribution in the HV windings Insulation materials used for HV winding LV winding Insulation material used between HV & LV winding LV winding & core Type of axial coil supports HV winding LV winding Type of radial coil supports HV winding LV winding Maximum allowable torque on coil clamping bolts Minimum clearance to earth(cms) LV & core HV & yoke

Page 15 of 72

CE(GSW)/SPV/BELAKAVADI

SOLAR PV POWER PLANT

SECTION-D TECH. PARTICULARS (TO BE FILLED BY THE TENDERER)

Sl. No. xvi) a) b) c) xvii)

a) b)

a) b) xviii) a) b) c) xix) a) b) 3 i) ii) iii) iv) v) a) b) vi) vii) a) b) viii) ix) x) xi) x) xii)

Description To be furnished by the bidder Capacitance HV winding to earth when LV earthed(pF) winding to earth when HV earthed (pF) Interwinding (pF) Insulation strength of windings(1.2/50 microsec wave) Impulse full wave (Withstand values) HV winding (KVP) LV Winding (KVP) Impulse chopped wave (Withstand values) HV winding (KVP) LV Winding (KVP) Separate source power frequency withstand voltage HV Winding (KV rms) LV Winding (KV rms) Neutral end of LV (KV rms) Induced over voltage withstand voltage (kV rms) HV Winding LV Winding BUSHINGS: Name of manufacturer Country Standards applicable Type of bushing rated voltage class (kV) rated current(Amps) Lightning impulse withstand voltage (KV peak) (1.2/50 microsecs) Power frequency withstand voltage(KV rms) Wet for 1 minute(kv rms) Dry for 1 minute(kV rms) Visible corona discharge voltage (KV rms) Partial discharge level Creepage distance in air( mm) Creepage distance (protected) whether test tap is provided Recommended gap setting

Page 16 of 72

CE(GSW)/SPV/BELAKAVADI

SOLAR PV POWER PLANT

SECTION-D TECH. PARTICULARS (TO BE FILLED BY THE TENDERER)

Sl. No. xiii) xiv) xv)

Description To be furnished by the bidder Quantity of oil in bushing (kgs) & specification of oil used Weight of assembled bushings in Kgs Minimum clearance height for removal of bushings(mm)

Page 17 of 72

CE(GSW)/SPV/BELAKAVADI

SOLAR PV POWER PLANT

SECTION-D TECH. PARTICULARS (TO BE FILLED BY THE TENDERER)

Sl. No. 4 i) a) b) ii) a) b) 5 i) ii) a) b) c) d) iii) iv) v) vi) vii) a) b) viii) a) b) 6 i. ii. iii.

a. b. c. d. e.

Description To be furnished by the bidder MINIMUM CLEARANCE(mm) In air (between phases & phase to ground) HV LV In oil (between phases & phase to ground) HV LV DETAILS OF TANK Type of tank Approximate thickness of sheet Sides Bottom Cover Cooling tubes/radiators Vaccum recommended for hot oil circulation(Torr) Vaccum to be maintained during oil filling in transformer tank(TORR) Vaccum to which the tank can be subjected without distortion(TORR) No. of bidirectional wheels provided Track guage required for the wheels Transverse axis Longitudinal axis Pressure relief device State whether it is self sealing type(After release of pressure) If self sealing type state the operating pressure CONSERVATOR Type( with or without air cell) Total volume (ltrs) Volume between the highest and lowest levels (ltrs.) OIL QUANTITY Governing standards Specific resistance(Ohm-cm)@ 27C 90C Tan delta Water content(ppm) Dielectric strength(BDV)kV
Page 18 of 72

CE(GSW)/SPV/BELAKAVADI

SOLAR PV POWER PLANT

SECTION-D TECH. PARTICULARS (TO BE FILLED BY THE TENDERER)

Sl. No.

Description f. Characteristics of oil after ageing test

To be furnished by the bidder

Page 19 of 72

CE(GSW)/SPV/BELAKAVADI

SOLAR PV POWER PLANT

SECTION-D TECH. PARTICULARS (TO BE FILLED BY THE TENDERER)

Sl. No. i)

Description To be furnished by the bidder Specific resistance(Ohm-cm)@ a. 27C b. 90C Tan delta ii) Sludge Content iii) Neutralisation number iv) Deatails of oil preserving equipment v) offered 7 COOLING EQUIPMENT Type i) Make ii) Type and No. of radiators iii) Estimated quantity of oil in radiators (ltrs) iv) v) 8 i) ii) iii) 9 i) a) b) c) d) e) ii) a) b) c) d) e) f) Heat Dissipating capacity in KW for each radiator BUCHHOLZ RELAY Make & Type No.of electrical contacts Rating of electrical contacts TEMPERATURE INDICATORS Oil temperature indicator Make & Type Permissible setting ranges for alarm & trip Range of instrument Number of electrical contacts Rating of contacts Winding temperature indicator Make & Type Permissible setting ranges for alarm & trip Range of instrument Number of electrical contacts Rating of contacts Whether remote indicators provided. If so equipments required at purchaser's control room is included Details of anti earthquake device provided if any

10

Page 20 of 72

CE(GSW)/SPV/BELAKAVADI

SOLAR PV POWER PLANT

SECTION-D TECH. PARTICULARS (TO BE FILLED BY THE TENDERER)

Sl. No. 11 i) ii) iii) a) b) c) iv) v) vi) vii) a) b) c) 13 a) b) c) 14 i) ii) a) b) iii) a) b) iv) v) vi) vii) viii) ix) x) xi) xii)

Description To be furnished by the bidder TAP CHANGING GEAR Make Type, designation, standard applicable Tap voltage as percent of no-load rated KV Plus. Minus % variation per step No. of steps Whether padlock provided Position of taps on the HV windings Percent impedance: Lowest Tap Highest Tap Normal Tap Cable boxes No. of cable boxes Rating of cable boxes Size of cables A) WEIGHTS Net Weight of core Net weight of HV winding LV winding Net weight of copper for HV winding LV winding Net weight of insulating oil Net untanking weight of core frame & coils Volume of insulating oil Total weight of radiators (without oil) Transport weight of transformer package with oil but without fittings to be dismantled during transport Transformer under inert gas Overall dimensions of the major packages Transformer tank (assembly) Total despatching weight of anciliary equipment Total weight of transformer when completely assembled

Page 21 of 72

CE(GSW)/SPV/BELAKAVADI

SOLAR PV POWER PLANT

SECTION-D TECH. PARTICULARS (TO BE FILLED BY THE TENDERER)

Sl. No. B) 1

2 a) i) ii) iii) b) 3 5 6 i) ii) 7 XX 1 2 3 4 5

Description To be furnished by the bidder DIMENSIONS Untanking height of core and coils(drawing of lifting arrangement shall be enclosed) Height of Crane hook for removing bushings Dimension of transformer when finally assembled Underbase to topmost point Overall breadth Overall length Dimension of transformer during movement from repair bay to its final position (LxBxH) Overall transporting dimensions of largest package (LxBxH) Vacuum withstand strength of tank Guage of rail track Parallel to the shorter axis Parallel to the longer axis Dia of wheels Disconnecting chamber, sub transient reactance, transient reactance 200 KVA Dry type transformer Name of the manufacturer Type of service (indoor/outdoor) Applicable standards No-load voltage ratio (guaranteed) Guaranteed continuous rating for the specified cooling, temperature rise over the ambient temperature (KVA) Guaranteed continuous overload rating (KVA) Rated voltage Primary, kV Secondary, kV Rated frequency Hz No. of phases Current at rated voltage & on principal tap Primary (Amps) Secondary (Amps) Vector group reference and symbol

6 7

8 9 10

11

Page 22 of 72

CE(GSW)/SPV/BELAKAVADI

SOLAR PV POWER PLANT

SECTION-D TECH. PARTICULARS (TO BE FILLED BY THE TENDERER)

Sl. No. 12

Description To be furnished by the bidder Guaranteed rated temperature rise above reference peak ambient temperature of air (deg. cen.) Of winding by resistance by hot spot temperature indicator for which the transformer is designed No. of windings 13 Limit for hot spot temperature for which 14 the transformer is designed Excitation current referred to H.V. at 50 15 Hz at normal ratio in percentage of rated current at 90% rated voltage at 100% rated voltage at 110% voltage Power factor for exciting current at 100% 16 rated voltage and 50 Hz. Guaranteed no-load losses at rated 17 voltage & frequency at principal tap (KW) (max. including tolerance, if any) No-load losses at the voltage 18 corresponding to the highest tap (KW) No-load loss 19 At 90% rated voltage (KW) At 100% rated voltage (KW) At 110% rated voltage (KW) Guaranteed load losses at rated output, 20 rated frequency and at 75 deg. cen. average winding temperature at principal tap (KW) (Max. including tolerance, if any) Load losses at rated output, rated 20 frequency and at 75 deg. cen. average winding temperature at a Highest tap b Lowest tap Guaranteed total losses at normal ratio, 21 rated output, rated voltage and rated frequency and at 75 deg. cen. (KW) (Max. including tolerance, if any) Positive sequence impedance on rated 22 KVA base at rated current & frequency at 75oC winding temperature at, Principal tap (%)

Page 23 of 72

CE(GSW)/SPV/BELAKAVADI

SOLAR PV POWER PLANT

SECTION-D TECH. PARTICULARS (TO BE FILLED BY THE TENDERER)

Sl. No.

Description Highest tap (%) Lowest tap (%)

To be furnished by the bidder

Page 24 of 72

CE(GSW)/SPV/BELAKAVADI

SOLAR PV POWER PLANT

SECTION-D TECH. PARTICULARS (TO BE FILLED BY THE TENDERER)

Sl. No. 23

24

27

25

26 i) ii) 27 i) ii) 28

i) ii) 29

i) ii) iii) iv) 30 31

Description To be furnished by the bidder 0 Zero Sequence impedence at 75 C Principal tap (%) Highest tap (%) Lowest tap (%) Resistance voltage drop at 750 C average winding temperature and rated full load expressed as percentage of rated KVA (All values to be referred to primary) Primary (%) Secondary (%) 0 Reactance voltage drop at 75 C and full load between windings expressed as % of rated voltage between Primary & Secondary (%) Guaranteed impedance voltage at normal tap and at 75 deg.cen. average winding temperature expressed as percentage of rated voltage (%) Impedance per phase Referred to Primary side (Ohms) Referred to Secondary side (Ohms) Test Voltages Lightning impulse withstand kV (peak) Power frequency voltage withstand kV (peak) Regulation at full load & 75 deg.cen. winding temperature expressed as a % of normal voltage at unity P.F at 0.8 P.F(lagging) Efficiencies at normal ratio, rated voltage, rated frequency and 75 deg. cen. average winding temperature for the output at unity p.f. & 0.8 p.f. corresponding to 100 % Load 75 % Load 50 % Load 25 % Load Maximum efficiency(%) Load at which maximum efficiency occurs (% of full load)

Page 25 of 72

CE(GSW)/SPV/BELAKAVADI

SOLAR PV POWER PLANT

SECTION-D TECH. PARTICULARS (TO BE FILLED BY THE TENDERER)

Sl. No. 32

Description To be furnished by the bidder Time in minutes for which the transformer can be run at full load without exceeding the maximum permissible temperature at reference ambient temperature Permissible overloading Terminal arrangement Primary side Secondary side Neutral Insulating & cooling medium Noise level when energised at normal voltage & frequency without load (db) External short circuit withstand capacity (KVA) & duration (secs.) Overflux withstand capability of the transformer corresponding to Factor 1.1 Factor 1.25 Factor 1.4 Ideal heating time or thermal time constant (Hours) ADDITIONALTECHNICAL PARTICULARS Details of core Type of core construction Type of joint between core limb & yoke Maximum flux density at rated voltage & frequency and at principal tap Core (weber/sq.mtrs) Yoke (weber/sq.mtrs) Max. flux density in iron at voltage and frequency 10% higher than normal (webers/sq.mtrs.) Core Yoke Magnetising current at normal ratio & frequency 90% of rated voltage 100% of rated voltage 110% of rated voltage Power factor of magnetising current at normal voltage, ratio & frequency Material of core lamination and grade Thickness of core lamination
Page 26 of 72

33 34 i) ii) iii) 35 36 37 38 i) ii) iii) 39

1 i) ii) iii) a b iv)

a b v) a b c vi) vii)a b

CE(GSW)/SPV/BELAKAVADI

SOLAR PV POWER PLANT

SECTION-D TECH. PARTICULARS (TO BE FILLED BY THE TENDERER)

Sl. No.

Description c Insulation between core lamination d Insulation of core bolts e Insulation of core bolt washers

To be furnished by the bidder

Page 27 of 72

CE(GSW)/SPV/BELAKAVADI

SOLAR PV POWER PLANT

SECTION-D TECH. PARTICULARS (TO BE FILLED BY THE TENDERER)

Sl. No.

Description To be furnished by the bidder f Core bolt insulation withstand voltage for 1 minute (kV rms) g Are the core bolts grounded. If so how h Area of cross section of core lamination.

i Material of core clamping plate j Thickness of core clamping plate k Insulation of core clamping plate Describe location/method of core l grounding Exciting va/kg or w/kg of lamination viii) material at a 15,000 gauss b Rated induction (vide item iii[a]) c Induction as per item (iv) 2 DETAILS OF WINDINGS: i) Type of Winding a Primary winding b Secondary winding ii) Material of the winding conductor a Primary winding b Secondary winding iii) Maximum current density of windings and conductor area (at rated current) a Current density(A/cm2) i) Primary winding ii) Secondary winding b Conductor area(cm2) i) Primary winding ii) Secondary winding iv) Type of joints in the windings Resistance of i) Primary winding(ohms/ph) ii) Secondary winding(ohms/ph) v) Whether windings are preshrunk vi) Insulation materials used for a Primary winding b Secondary winding vii) Partial discharge level at 1.5Um/sqrt(3) kv rms

Page 28 of 72

CE(GSW)/SPV/BELAKAVADI

SOLAR PV POWER PLANT

SECTION-D TECH. PARTICULARS (TO BE FILLED BY THE TENDERER)

Sl. No. 3 i) ii) iii) iv) v) vi) vii) viii) 4 i) ii) iii) iv) v) 5 i) ii) iii) a b c iv) a

v) vi) 6 i) ii) a b iii) a b

Description BUSHINGS: Name of manufacturer Country Standards applicable Type of bushing rated voltage class (kV) rated current(Amps) Creepage distance in air( mm) Creepage distance (protected) WINDING TEMPERATURE INDICATORS Make & Type Permissible setting ranges for alarm & trip Range of instrument Number of electrical contacts Rating of contacts TAP CHANGING GEAR Make Type, designation, standard applicable Tap voltage as percent of no-load rated KV Plus Minus % variation per step No. of steps Percentage impedance i) Lowest tap ii) Highest tap iii) Normal tap Whether padlock provided Position of taps on the HV windings WEIGHTS Net Weight of core Net weight of Primary winding Secondary winding Net weight of copper for Primary winding Secondary winding

To be furnished by the bidder

Page 29 of 72

CE(GSW)/SPV/BELAKAVADI

SOLAR PV POWER PLANT

SECTION-D TECH. PARTICULARS (TO BE FILLED BY THE TENDERER)

Sl. No. XXI 1 2 3 4 5 i) ii) iii) 6

Description 66 KV ISOLATORS Type , make , and country of origin Applicable standard Maximum permissible continuous service voltage(KV) Whether remote controlled Clearance in air ( minimum ) Between phases ( mm ) Between live parts and earth(mm) Distance between centres of outer stacks of insulators ( mm ) One minute dry and wet power frequency withstand test voltage for complete assembled isolator / isolator cum earthing switch ( KV rms ) Against ground Across open contact 1.2 / 50 microsecond lightning impulse withstand test voltage on complete assembled isolator / isolator cum earthing switch KV(peak) Between live parts and ground . Across the open terminals of the same phase Radio interference voltage ( Micro Volts ) Particulars of main contacts i.e ., fixed contacts ( main and earthing switch ) and moving contacts ( main and earthing switch) Ttype Fixed contacts Moving contacts Material. Surface treatment and thickness of surface coating Contact area(sqmm) Contact pressure(kgs/sqmm) Current density at the minimum cross section of switch blade ( A / sq.mm ) Continuous current rating(Amps) Short time current rating I ) For 1. Sec.( KA rms ) ii ) for 3. Sec ( KA rms )

To be furnished by the bidder

i) ii) 7

i) ii) 8 9

i) a b ii) iii) iv) v) 10 11 12

Page 30 of 72

CE(GSW)/SPV/BELAKAVADI

SOLAR PV POWER PLANT

SECTION-D TECH. PARTICULARS (TO BE FILLED BY THE TENDERER)

Sl. No. 13 14

Description To be furnished by the bidder Rated peak short circuit current for Main blade ( KA peak ) Rated peak short circuit current for earthing blade ( KA peak )

Page 31 of 72

CE(GSW)/SPV/BELAKAVADI

SOLAR PV POWER PLANT

SECTION-D TECH. PARTICULARS (TO BE FILLED BY THE TENDERER)

Sl. No. 15 i)

Description To be furnished by the bidder Temparature rise corresponding to ; Max. continuous current rating at 40 deg C ambient temparature ii) short time current rating a i) for 1 second b ii) for 3 second 16 Max.transformer magnitising breaking current which can be safely inetrupted by the switch . Amps ( p.f ) 17 Max. capacitive breaking current which can be safely interrupted by the switch . Amps ( p.f ) 18 Max. current that can be safely interupted between equipotential busbars ( Amps ) 19 No. of operations which the switch can withstand without deterioration of contacts. 20 No.of times the switch can be operated without any need for inspection 21 Auxillary switches.( for both Main & Earth switch). i) No. of NO and NC contacts ii) Rated voltage(DC) iii) Rated current ( Amps ) iv) Test voltage ( KV ) 22 Phase to phase distance ( mm ) 23 Type of mounting whether horizontol upright or under hung 24 Number of breaks per phase 25 Power required by DC interlocking coil at 250 volts and its make 26 Safety factor taken into account while designing the isolator 27 Whether terminal connectors provided and if so indicate the type and material used 28 Rated mechanical terminal load a) Longitudinal ( straight ) b) transverse ( or cross ) 29 Whether arcing contacts provided if so , give type and material used

Page 32 of 72

CE(GSW)/SPV/BELAKAVADI

SOLAR PV POWER PLANT

SECTION-D TECH. PARTICULARS (TO BE FILLED BY THE TENDERER)

Sl. No. 30

31

Description To be furnished by the bidder Whether separate operating mechanism provided for operation of main blade and earthing blade. Location and type of bearing

Page 33 of 72

CE(GSW)/SPV/BELAKAVADI

SOLAR PV POWER PLANT

SECTION-D TECH. PARTICULARS (TO BE FILLED BY THE TENDERER)

Sl. No. 32 i) ii) iii) iv) a b c d v) vi) vii) viii) ix) a b x) xi) xii) xiii) xiv) xv) xvi) xvii) 33 34 35 36 37 38 39

Description To be furnished by the bidder Particulars of insulators Make Type Size Strength(kgs) Compressive Tensile Torsional Cantilever Strength Weight(kgs) No. of units per stack Diameter of shed (mm) Height of stack Creepage distance(mm) Total Protected Bolt circle dia. Top / bottom(mm) 1 minute power frequency withstand voltage ( KV rms ) Switching impulse withstand voltage ( KV rms ) Power frequency flashover voltage ( kV peak ) Impulse flashover voltage ( KV peak ) Lightning impulse withstand voltage ( KV ) Corona extinction voltage ( KV ) Puncture voltage ( KV ) Weight of three pole isolating switch without earthing blade(kgs) Weight of three pole isolating switch with earthing blade ( kgs ) Type of interlocking between isolating switch and earth switch. Torque required to open the switch ( kg-m) Test voltage of coil Closing time ( sec ) Total D.C. energy requirement of the control circuit for operating 'voltage of 250 Volts Dc Tolerence permissible in the D.C operating voltage ( percentage )

40

Page 34 of 72

CE(GSW)/SPV/BELAKAVADI

SOLAR PV POWER PLANT

SECTION-D TECH. PARTICULARS (TO BE FILLED BY THE TENDERER)

Sl. No. 41 42 43

Description To be furnished by the bidder Opening time of the isolating switch ( sec ) Weight of the operating mechanism (kgs) Type of interlocks provided

Page 35 of 72

CE(GSW)/SPV/BELAKAVADI

SOLAR PV POWER PLANT

SECTION-D TECH. PARTICULARS (TO BE FILLED BY THE TENDERER)

Sl. No. 44 i) ii) a b iii)

Description To be furnished by the bidder Motor operating mechanism Type Motor Rating ( Voltage , current , H.P ) Duty Power at normal operation required for a Interlocking coils ( watts ) b Heating element iv) Type of stop for limit position offered v) Operating time ( sec ) vi) Details of arrangement of emergency local / manual operating provided. 45 Actual dimensions of isolator 46 Dimension of base in mm . 47 MOM box particulars i) Manufacturer's Name ii) Indoor / Outdoor application iii) Thickness of sheet metal iv) Degree of protection v) Bill of materials for various equipment , ratings etc., vi) Colour of finished paint outside/inside

Control wiring / power wiring a Material of conductor & size b Conductor - solid / stranded viii) Type of mounting ix) Cable entry x) Space heater / lighting supply voltage / control voltage xi) Design ambient temparature 48 Terminal connectors i) Type ( bi-metalic or aluminium ) ii) Whether suitable for ACSR Drake iii) Material used 49 Support structure i) Material used ii) Whether galvanised

vii)

Page 36 of 72

CE(GSW)/SPV/BELAKAVADI

SOLAR PV POWER PLANT

SECTION-D TECH. PARTICULARS (TO BE FILLED BY THE TENDERER)

Sl. No. XXII

Description 66 KV SF6 GAS CIRCUIT BREAKERS Makers Name and country of manufacture Manufacturer's type & designation Applicable standards Rated voltage and frequency Number of poles Class: Indoor or outdoor Rated insulation level Normal current rating Under normal conditions Under site conditions Max.ambient temperature assumed for design Max.rise of temp.over ambient for Continuous rated current Short circuit current Short time current rating 1Sec. 3 Secs. Rated line charging breaking current with the over voltage not exceeding 2.5 pu Rated line charging breaking current and corresponding overvoltage recorded in test Supply side Line side Rated cable charging breaking current and corresponding over voltages recorded in tests Supply side Line side

To be furnished by the bidder

1 2 3 4 5 6 7 8 i) ii) 9 10 i) ii) 11 i) ii)

12

13 i) ii)

14 i) ii) 15 16 17

Rated(single) capacitor breaking current Rated small inductive breaking current Rated short circuit breaking current i) r.m.s.value of AC current ii) Percentage of DC component Symmetrical breaking current (including iii) DC component) 18 First-pole-to-clear factor a)Rated transient recovery voltage for 19 terminal faults.
Page 37 of 72

CE(GSW)/SPV/BELAKAVADI

SOLAR PV POWER PLANT

SECTION-D TECH. PARTICULARS (TO BE FILLED BY THE TENDERER)

Sl. No. 20 21 22

Description b) Method of representing TRV Rated characteristics for short line fault Rated short circuit making current Rated operating sequence

To be furnished by the bidder

Page 38 of 72

CE(GSW)/SPV/BELAKAVADI

SOLAR PV POWER PLANT

SECTION-D TECH. PARTICULARS (TO BE FILLED BY THE TENDERER)

Sl. No. 23 24

25

26 27 i) ii) iii) 28 29 30 31 32 i) ii) 33 34 35

36

37 38 i) a b c ii) a b

39

Description To be furnished by the bidder Rated out of phase breaking current Max. capacity under phase opposition Reactor loaded transformer interrupting capacity and corresponding switching surge over voltage Capacity for interrupting in rush current of transformers and corresponding over voltage capacity for interrupting Data on restriking voltage Amplitude factor Phase factor Rate of rise of restriking voltage and the device to limit the same Is the circuit breaker restrike free Opening time Maximum break time Closing time Minimum dead time 3 Phase reclosing Single phase reclosing Make time and arcing time Linking mechanism for single pole units Details of construction of linking mechanism Max. difference in time between the instants of contacts touching during closing between poles. Max.difference in time between the instants of contact seperating during opening between poles i)Max. voltage factor of the circuit breaker when switching off; Unloaded transformers Loaded transformers Open circuited lines When switching off asynchronous system Maximum current Maximum recovery voltage between contacts of one pole Total interrupting time measured from instant of trip coil energisation to arc extinction of resistor current

Page 39 of 72

CE(GSW)/SPV/BELAKAVADI

SOLAR PV POWER PLANT

SECTION-D TECH. PARTICULARS (TO BE FILLED BY THE TENDERER)

Sl. No.

40 41

Description Min. reclosing time at full rated interrupting capacity from the instant of trip coil energisation Min. clearance in open air a) between phases b)to earth

To be furnished by the bidder

Page 40 of 72

CE(GSW)/SPV/BELAKAVADI

SOLAR PV POWER PLANT

SECTION-D TECH. PARTICULARS (TO BE FILLED BY THE TENDERER)

Sl. No. 42 i) ii) 43 i) ii) 44 45 i) ii) 46 47 48 49 50 51 52 53 i) ii) iii) iv) v) 54 i) ii) iii) iv) 55 56 57 58 59 i)

Description To be furnished by the bidder One minute power frequency withstand test voltage between line terminals and grounded objects between terminals with breaker contacts open 1.2/50 micro second full wave impulse withstand test voltage between line terminals and grounded objects between terminals with breaker contacts open Corona extinction voltage Radio interference voltage Test voltage RI value Number of breaks in series per pole Total length of break per phase Type of device used to limit the rate of restriking voltage Whether the circuit breaker is trip free Type of main contacts Type of arcing contacts and/or arc control device Contact pressure Material of contacts Main Arcing Auxiliary Contacts surface plating Thickness of silver plating Number of spare auxiliary contacts provided Those closed when breaker is closed Those open when breaker is closed Rating of auxiliary contacts Breaking capacity of auxiliary contacts Type of operating mechanism b) for tripping Rated voltage of trip & closing coils Pick up range of trip coil Pick up range of closing coil Power required for trip coil and closing coil at its rated voltage

Page 41 of 72

CE(GSW)/SPV/BELAKAVADI

SOLAR PV POWER PLANT

SECTION-D TECH. PARTICULARS (TO BE FILLED BY THE TENDERER)

Sl. No.

Description ii) at 85% rated load

To be furnished by the bidder

Page 42 of 72

CE(GSW)/SPV/BELAKAVADI

SOLAR PV POWER PLANT

SECTION-D TECH. PARTICULARS (TO BE FILLED BY THE TENDERER)

Sl. No. 60 61 i) ii) a b iii) iv) v) 62 i) ii) 63 i) ii) iii) iv) v) vi) vii) viii) ix) x) xi) 64 i) ii) a b iii)

Description To be furnished by the bidder Number of operations at rated capacity the breaker is capable of performing without inspection /replacement of contacts or other main parts Pressure of SF6 gas Range of gas pressure for satisfactory operation Monitor for SF6 gas One for each pole Common for all the 3 poles Volume of SF6 gas per pole and gas pressure Leakage of SF6 gas permissible Provision available for isolating SF6 gas leaking pole from other healthy poles. Details of interlock provided against low pressure operation remote operation manual operation Insulator Make Type Dimension 1 minute dry power power frequency with stand voltage Flash over voltage Full wave impulse with stand voltage Carona discharge voltage Nature of dielectric medium Creepage distance total/ protected Permissible safe cantilever load on installed porcelain Insulation class Pneumatic or Spring/Pneumatic operating mechanism: Rated operating pressure kg/sq.cm b)Range of pressure for Closing Opening

c) Air consumption at rated pressure for a Closing b Opening c Close- Open

Page 43 of 72

CE(GSW)/SPV/BELAKAVADI

SOLAR PV POWER PLANT

SECTION-D TECH. PARTICULARS (TO BE FILLED BY THE TENDERER)

Sl. No. iv)

Description Number and capacity of local air receiver Time required for filling the air receiver to its rated pressure from atmospheric pressure.

To be furnished by the bidder

v)

Page 44 of 72

CE(GSW)/SPV/BELAKAVADI

SOLAR PV POWER PLANT

SECTION-D TECH. PARTICULARS (TO BE FILLED BY THE TENDERER)

Sl. No. vi)

Description To be furnished by the bidder Design pressure of air receiver Number of closing opening operations possible without charging the air vii) receiver. Arrangement provided for preventing the viii) operation of the breaker with insufficient air pressure. ix) Compressor a Make and size b No. of cylinders c No. of compression stage d Compression pressure after each stage Whether compressor is provided with its e own filter, if so, its type and make. Effectively delivered air in litres per f hour, at atmospheric pressure. g Maximum pressure h Driving Motor a)Make and type of the driving motor b) Horse power of driving motor c) Class of insulation d) Whether thermal over load protection provided with motor starter e) Starting time With 100% voltage at terminals With 85% voltage at terminals With 80% voltage at terminals f) Safe stall time at 100% rated voltage and under hot conditions. g) Type of bearings provided and expected life. h) Total weight of motor. i) Type and size of cable for which gland provided in the terminal box. Type and Routine type certificates i enclosed. Safety valve settings mounted on air j receiver Temperature rise of compressor while working at full load at ambient of 50 k deg.C. l Type of cooling

Page 45 of 72

CE(GSW)/SPV/BELAKAVADI

SOLAR PV POWER PLANT

SECTION-D TECH. PARTICULARS (TO BE FILLED BY THE TENDERER)

Sl. No.

Description m Pressure settings of a)Safety valve on local storage reservoir b) Compressor starting

To be furnished by the bidder

Page 46 of 72

CE(GSW)/SPV/BELAKAVADI

SOLAR PV POWER PLANT

SECTION-D TECH. PARTICULARS (TO BE FILLED BY THE TENDERER)

Sl. No.

x) a b c 65

66 i) ii) iii) 67 i) ii) 68 69 i) ii) 70 71 72 73 i) ii)

Description c)Compressor cut-off d)Low pressure alarm for local storage reservoirs. Compressed air piping Material Inner and outer diameter in mm Working pressure in kg/sq.cm. Spring/Spring operating mechanism: a) Make and type of spring charging motor b)Horse power of Motor c) Class of insulation d) Type of of bearing and expected life e)Total weight of motor f)Type of Routine Test Certificate g) No. of close-open operation possible after failure of AC supply to motor h)Time required for motor to charge the closing spring i) Whether indication of spring charged condition provided in central control cabinet j) Type and rating of the spring: k)Whether the breaker is single phase individually operated/ three phase gang operated Overall dimensions Height Width Length Weight Each pole Complete breaker Impact loading for foundation design Noise level While opening While closing Details of supporting structure Details of central control cabinet SF6 gas density monitor whether provided. Terminal clamps: Manufacturer's Name Alloy composition of clamp body& bolts

To be furnished by the bidder

Page 47 of 72

CE(GSW)/SPV/BELAKAVADI

SOLAR PV POWER PLANT

SECTION-D TECH. PARTICULARS (TO BE FILLED BY THE TENDERER)

Sl. No.

Description To be furnished by the bidder Range of dia. of conductors that can be iii) received Max temp.risewhen carrying rated current iv) at 50 deg.C ambient

Page 48 of 72

CE(GSW)/SPV/BELAKAVADI

SOLAR PV POWER PLANT

SECTION-D TECH. PARTICULARS (TO BE FILLED BY THE TENDERER)

Sl. No. v) vi) vii) viii) ix) x) 74

75 76 77 i) ii) iii) iv) v) vi) a b vii) viii) ix) x) 78 i) ii) iii) iv) v) vi) vii) viii) ix) x) xi)

Description To be furnished by the bidder Weight of each clamp/type Continuous current rating Application Applicable standard Whether horizontal or vertical take off Minimum thickness of any part All wiring of breaker cubicle, control block etc furnished Impact loading for foundation design to include dead load plus impact value of opening at max.interupting rating in terms of static load Whether S.C.Test Certificate enclosed Marshalling box particulars Manufacturers Name Indoor/Outdoor application Thickness of sheet metal Degree of protection Colour of finished paint out side/inside Control wiring/Power wiring Material of conductor & size Conductor-Solid/Stranded Type of mounting Cable entry Space heater/lighting supply /control voltage Design ambient temparature Guaranteed Technical Particulars of SF6 Gas Physical properties Density at 20 deg.C and 1 bar Electric strength Compatibility Toxic impurities Dew point Impurities Standard sizes of cylinder Prefered sizes of cylinder Test pressure of cylinders Max. filling ratio for tropical country

XXIII 1

60 KV LIGHTNING ARRESTERS Name of the manufacturer


Page 49 of 72

CE(GSW)/SPV/BELAKAVADI

SOLAR PV POWER PLANT

SECTION-D TECH. PARTICULARS (TO BE FILLED BY THE TENDERER)

Sl. No. 2 3 4

Description Manufacturer's type designation Applicable standards Rated Voltage (KV rms)

To be furnished by the bidder

Page 50 of 72

CE(GSW)/SPV/BELAKAVADI

SOLAR PV POWER PLANT

SECTION-D TECH. PARTICULARS (TO BE FILLED BY THE TENDERER)

Sl. No. 5 6 7

8 i) ii) iii) 9

10 i) ii)

11 12 13

14

15

16 17 i) ii) 18 19 20 21

22

Description To be furnished by the bidder Maximum continuous operating voltage (KV rms) Nominal discharge current(KA peak) Long duartion discharge class and energy discharge capacity (KJ/KV) Maximum lightning impulse residual voltage for discharge current of 8/20 micro sec. Wave (KV peak) 5 KA 10 KA 20 KA Residual voltage for 1 micro second steep front current of 10 KA (KV peak) Residual voltage for switching impulse current with virtual front time greater than 30 micro second but less than 100 micro seconds & magnitude of 250 Amps (KV peak) 1000 Amps. (KV peak) Resistive and capacitive component of the continuous current at ambient temperature (mA) Pressure relief class Number of sections in complete unit Impulse current withstand capacity.Short duration high current (4/10 Micro -sec wave)(KA peak) One minute power frequency (dry) withstand voltage of arrester housing (KV rms) Impulse withstand test voltage of arrester housing with 1.2/50 micro sec wave (KV peak) Creepage distance of arrester housing (mm) Total protected Cantiliver strength of complete arrester kgs Total height of arrester (mm) Total weight of the arrester (kgs) Maximum radio interference voltage at test voltage (micro volts) Shipping weight and volume of biggest package(kgs)

Page 51 of 72

CE(GSW)/SPV/BELAKAVADI

SOLAR PV POWER PLANT

SECTION-D TECH. PARTICULARS (TO BE FILLED BY THE TENDERER)

Sl. No. 23 24

Description To be furnished by the bidder Particulars of surge counter (make , type, etc.,) Particulars of terminal connectors suitable for ACSR Drake conductor

Page 52 of 72

CE(GSW)/SPV/BELAKAVADI

SOLAR PV POWER PLANT

SECTION-D TECH. PARTICULARS (TO BE FILLED BY THE TENDERER)

Sl. No. 25 i) ii) 26 i) ii) iii) iv) v) vi)

Description Maximum permissible length of lead between Arrester and surge counter surge counter and earth Support structures Height Breadth Width Material Weight /structure (kgs) Whether hot dip galvanised

To be furnished by the bidder

XXIV 1 2 3 4 5 6 7 8 9 10 11 12

66 KV CURRENT TRANSFORMERS Type of CTs Manufacturer's Name Standard Applicable Rated Voltage kV (rms) Rated Primary Current Rated Secondary Current Type of Primary Winding No. of Primary turns No. of Secondary turns No of Cores per CT Insulation Class of Windings Primary Winding Rated Primary Current Current Ratio Secondary Winding Rated Secondary Current Class of Accuracy Rating of VA Burden Sec.limiting Voltage Short time thermal rating of primary winding for One second Three seconds Rated dynamicCurrent(Peak Value) Max. temparature rise at rated current &burden over ambient temparature of Winding Oil at top Exposed current carrying parts

13 14 15 16 17 18 i) ii) 19 20 i) ii) iii)

Page 53 of 72

CE(GSW)/SPV/BELAKAVADI

SOLAR PV POWER PLANT

SECTION-D TECH. PARTICULARS (TO BE FILLED BY THE TENDERER)

Sl. No. 21 22

Description One minute power frequency dry withstand test voltage One minute power freequency wet withstand test voltage

To be furnished by the bidder

Page 54 of 72

CE(GSW)/SPV/BELAKAVADI

SOLAR PV POWER PLANT

SECTION-D TECH. PARTICULARS (TO BE FILLED BY THE TENDERER)

Sl. No. 23

Description 1.2/50 micro second impulse with-stand test voltage,KV(peak) One minute power freequency with stand test voltage on secondaries,KV(rms) Temparature rise after passing short time thermal current for a) One second b) Three seconds Current density in primary winding at (Amps./Cm2) Normal rating Short time rating for 1second. Short time rating for 3seconds. Dynamic rating Flux density at knee point voltage Charecteristic curves whether furnished Ratio & Phase angle curve Magnatisation curve Ratio correction factor curve Limits of composite error at rated primary saturation current Minimum knee point voltage of each core Max.exciting current at knee point Resistance of the sec.winding Sec.impedence value (ohms) Radio interference voltage microvolt Variation in ratio& phase angle error due to variation in Voltage, current & frequency Type of pressure relief device provided Total/Protected creepage distance in mm Mounting details Overall dimensions Grade & make of oil Weight of oil Total weight Terminal Connectors Type Suitable for ACSR drake Material used Type of painting Marshalling Box details degree of protection

To be furnished by the bidder

24 25

26 i) ii) iii) iv) 27 28 i) ii) iii) iv) 29 30 31 32 33

34 35 36 37 38 39 40 41 42 i) ii) iii) 43 44 i)

Page 55 of 72

CE(GSW)/SPV/BELAKAVADI

SOLAR PV POWER PLANT

SECTION-D TECH. PARTICULARS (TO BE FILLED BY THE TENDERER)

Sl. No. ii) iii) iv) v)

Description outdoor application colour of paint type of mounting cable entry

To be furnished by the bidder

Page 56 of 72

CE(GSW)/SPV/BELAKAVADI

SOLAR PV POWER PLANT

SECTION-D TECH. PARTICULARS (TO BE FILLED BY THE TENDERER)

Sl. No.

Description To be furnished by the bidder vi) design ambient temperature vii) space heater/lighting voltage/control voltage viii) design ambient temperature 45 Support structure i) Height(mm) ii) Breadth(mm) iii) Width(mm) iv) Material used v) Weight/structure(kgs) vi) Whether hot dip galvanised

XXV 1 2 3 4 5 6 i) ii) 7 i) ii) 8 i) ii) 9 10 11 12 13

66 KV POTENTIAL TRANSFORMERS Type Manufacturer's Name Standard Applicable Rated Voltage kV (rms) No of secondary windings Rated Secondary Voltage Winding 1 Volts Winding 2 Volts Rated Burden(VA) Winding 1 Winding 2 Accuracy Class Winding 1 Winding 2 Max. ratio error with rated burden & 5% normal primary voltage Max. Phase angle error with rated burden & 5% normal primary voltage Temperature rise at 1.1 times rated voltage with rated burden Rated voltage factor &Time Temperature rise at 1.5 times rated voltage with rated burden when applied for 30secs starting from normal operation One minute power frequency dry withstand test voltage KV(rms) One minute power frequency wet withstand test voltage KV(rms) 1.2/50 micro secondimpulse wet withstand test voltage KV(peak)
Page 57 of 72

14 15 16

CE(GSW)/SPV/BELAKAVADI

SOLAR PV POWER PLANT

SECTION-D TECH. PARTICULARS (TO BE FILLED BY THE TENDERER)

Sl. No. 17 18

Description One minute power frequency withstand test voltage on secondaries KV(rms) Type and class of insulation

To be furnished by the bidder

Page 58 of 72

CE(GSW)/SPV/BELAKAVADI

SOLAR PV POWER PLANT

SECTION-D TECH. PARTICULARS (TO BE FILLED BY THE TENDERER)

Sl. No. 19 i) ii) 20 21 22 23 i) ii) 24 25 26 i) ii) iii) XXVI A 1 i) ii) iii) iv) 2 i) ii) iii) iv) v) vi) vii)

Description Variation in ratio and phase angle error for variation in Voltage by 1% Frequency by 1 Hz Grade and make of oil Weight of oil an Kgs Total weight in Kgs Creepage distance(mm) Total Protected No. of earthing terminals provided Type of painting provided for base/ secondary box Terminal connectors Type(Bimetallic or Aluminium) Material used Applicable standards CONTROL AND PROTECTION PANELS

To be furnished by the bidder

NUMERICAL RELAY FOR TRANSFORMER PROTECTION DETAILS OF RELAY Type Make Programming Language No. of Processor used TECHNICAL DATA OF HARDWARE ANALOG INPUT VARIABLES Number of Inputs (Current / Voltage) Rated Frequency Rated Current Thermal Rating of Current Circuit Rated Voltage Thermal Rating of Voltage Circuit Burden per Phase Current Inputs Voltage Inputs CONTACT DATA: TRIPPING RELAYS No. of Contacts Maximum Operating Voltage Continuous Rating
Page 59 of 72

a 1 i) ii) iii)

CE(GSW)/SPV/BELAKAVADI

SOLAR PV POWER PLANT

SECTION-D TECH. PARTICULARS (TO BE FILLED BY THE TENDERER)

Sl. No. iv) v) vi)

Description Make and Carry for 0.5 Sec. Surge for 30 ms Making Power at 110 V DC

To be furnished by the bidder

Page 60 of 72

CE(GSW)/SPV/BELAKAVADI

SOLAR PV POWER PLANT

SECTION-D TECH. PARTICULARS (TO BE FILLED BY THE TENDERER)

Sl. No. b i) ii) iii) iv) v) vi) c i) ii) iii) iv) v) d i) ii) iii) e i) f i) ii) iii) g i) ii)

Description SIGNALLING RELAYS No. of contacts Maximum operating voltage Continuous Rating Make and Carry 0.5 Sec. Surge for 30 ms Making Power at 110 V D.C. OPTO COUPLER INPUTS No. of opto couplers Input voltage Threshold voltage Max. input current Operating time CONFIGURATION AND SETTINGS Local via communication interface PC compatibility Remote via Modem

To be furnished by the bidder

HUMAN MACHINE INTERFACE LOCAL CONTROL Whether HMI on relay is provided REMOTE COMMUNICATION Serial Interface LAN / FO interface Data Transfer Rate AUXILIARY SUPPLY Voltage AC and Range Voltage DC and Range

TECHNICAL DATA OF PROTECTION FUNCTIONS: MAIN FUNCTIONS List of functions available List of measurement functions Details of settings available Current setting Bias slope Inrush inhibit High set over current Current amplitude correction
Page 61 of 72

i) ii) iii) a b c d e

CE(GSW)/SPV/BELAKAVADI

SOLAR PV POWER PLANT

SECTION-D TECH. PARTICULARS (TO BE FILLED BY THE TENDERER)

Sl. No. f g h

Description Vector group compensation Restricted earth fault Circuit breaker fail

To be furnished by the bidder

Page 62 of 72

CE(GSW)/SPV/BELAKAVADI

SOLAR PV POWER PLANT

SECTION-D TECH. PARTICULARS (TO BE FILLED BY THE TENDERER)

Sl. No. i) ii) iii)

Description ANCILLIARY FUNCTIONS Logic Delay / Integrator Plausibility Check

To be furnished by the bidder

LIST OF MEASUREMENT FUNCTIONS Currents Voltages Phase angle Power Frequency DISTURBANCE RECORDER FEATURES Maximum number of analogue channels Maximum number of binary channels Sampling Frequency Available Recording Time Recording initiation Settings : Recording Periods : (i) Pre-event (ii) Event (iii) Post-event Software Details No. of event records GENERAL DATA Temperature Range Operation Storage Humidity Seismic Test Insulation Test Leakage Resistance Surge Voltage Test 1 MHZ disturbance Test Fast transient Test Electrostatic Discharge Test Radio Frequency Interference Test Emission Applicable Standards
Page 63 of 72

i) ii) iii) iv) v) vi)

vii) viii) i)

ii) iii) iv) v) vi) vii) viii) ix) x) xi) xii)

CE(GSW)/SPV/BELAKAVADI

SOLAR PV POWER PLANT

SECTION-D TECH. PARTICULARS (TO BE FILLED BY THE TENDERER)

Sl. No. i) ii)

Description DISPLAY Type Displayed parameters

To be furnished by the bidder

Page 64 of 72

CE(GSW)/SPV/BELAKAVADI

SOLAR PV POWER PLANT

SECTION-D TECH. PARTICULARS (TO BE FILLED BY THE TENDERER)

Sl. No. i) ii) iii)

Description MECHANICAL DESIGN Weight Methods of mounting Enclosure Protection Class MINIMUM P.C. HARDWARE REQUIREMENT Operating system Memory capacity Software

To be furnished by the bidder

4 i) ii) iii) B 1 i) ii) iii) iv)

v)

vi)

vii) viii) ix) x) xi) xii)

DISCRETE NUMERICAL PROTECTION RELAYS Non-directional Over-Current & E/F Relays Type Current Coil Rating Tap Range VA Burden Highest Tap Lowest Tap Power Consumption : Highest Tap Lowest Tap Time of operation at Maximum time dial setting at (i) 5 times tap setting current (ii) 10 times tap setting current Type of characteristic Whether draw out type Trip contact rating - Amps Whether seal in contacts provided or not - Yes / No. Whether HMI on relay is provided Details of communication facilities (Ports, Protocol etc.) Numerical Earth Fault Relay : Type Current Rating Operating Coil Polarizing Coil Tap Range VA Burden Operating Coil -(I) Highest Tap
Page 65 of 72

2 i) ii)

iii) iv)

CE(GSW)/SPV/BELAKAVADI

SOLAR PV POWER PLANT

SECTION-D TECH. PARTICULARS (TO BE FILLED BY THE TENDERER)

Sl. No. v)

Description (ii) Lowest Tap Power Consumption Operating Coil -(I) Highest Tap (ii) Lowest Tap

To be furnished by the bidder

Page 66 of 72

CE(GSW)/SPV/BELAKAVADI

SOLAR PV POWER PLANT

SECTION-D TECH. PARTICULARS (TO BE FILLED BY THE TENDERER)

Sl. No. vi)

vii) viii) ix) x) xi) C i) ii) iii) iv)

Description To be furnished by the bidder Time of Operation at maximum time dial setting at (i) 5 Times tap setting (ii) 10 Times tap setting Whether draw-out type or not. Trip contact rating - Amps Whether seal in contact provided or not Whether HMI on relay is provided Details of communication facilities (Ports, Protocol etc.) AUXILIARY RELAYS Operating DC Voltage Type Permissible variation in DC Voltage without effecting operation Output contacts: i) No. of contacts ii) Rating iii) Make & carry current for 0.5 sec iv) Breaking Environment i) Temperature ii) Humidity iii) Vibration endurance INDICATING METERS Quantity & Purpose Type Make Measuring range with suitable CT/PT ratio VA burden Current coil / potential coil Power consumption ISS/BSS grade of accuracy SWITCHES Type & quantity of switches Make No. of ways & poles Current rating for make and break at rated voltage PANEL DETAILS
Page 67 of 72

v)

D a b c d e f g

E
a b c d F

CE(GSW)/SPV/BELAKAVADI

SOLAR PV POWER PLANT

SECTION-D TECH. PARTICULARS (TO BE FILLED BY THE TENDERER)

Sl. No. a b c

Description Dimension of panel Weight of panel Ingress protection (Reqd. IP 21)

To be furnished by the bidder

Page 68 of 72

CE(GSW)/SPV/BELAKAVADI

SOLAR PV POWER PLANT

SECTION-D TECH. PARTICULARS (TO BE FILLED BY THE TENDERER)

Sl. No. G a b c d e f g h i j

k l m

Description To be furnished by the bidder ENERGY METER Type of meter Make Standard to which the meter confirms System voltage Basic current Nominal frequency Power loss in each current circuit at basic current in VA Power loss in each voltage circuit at reference in VA and Watt Accuracy class Display device (Hardware details) i) Type of display ii) Character size of display digits iii) No. of display digits used for data and parameter identification Type of mounting Time synchronising features Maximum number of parameters which can be stored in the non volatile memory at each 15 minute interval for 35 days i) Provision for real time clock ii) Real time clock accuracy iii) Life of real time clock (guaranteed) Communication features i) Type ii) Protocol

XXVII 1 2 3 4 5 6 7 8 9 10 11 12

BATTERY & BATTERY CHARGER Type & make No of chargers Float charger capacity Boost charger capacity Momentary DC bus load Continuous DC bus load Float charger current of battery Boost charger current of battery Voltage regulation Harmonics at rated load Without battery Type & No. of thyristors PIV & current rating of thyristors
Page 69 of 72

CE(GSW)/SPV/BELAKAVADI

SOLAR PV POWER PLANT

SECTION-D TECH. PARTICULARS (TO BE FILLED BY THE TENDERER)

Sl. No. 13 14 15 16 17 18 19 20 21

Description Rated out put voltage of charger Type & make of battery No. of battery banks No. of batteries in each bank Ampere hour rating of each bank Recommended boost charging current Recommended float charging current Dimensions of battery stand Maximum momentary current for one minute

To be furnished by the bidder

XXVIII SCADA SYSTEM 1 Hardware i) Work station PC / Server details: Make, quantity, processor, RAM, HDD, monitor, network card ii) Laser printer details Make, type, size, DPI 2 Data bus & network hardware i) Type ii) 100% redundancy Medium (twisted pair/coaxial/ fibre optic iii) with characteristic impedance) iv) Data transfer rate v) Topology (ring/bus) vi) Physical layer details 3 Software Details i) Operating System ii) Programming language iii) Remote Communication Details XXIX 1 2 3 i) ii) iii) 4 i) ii) 5 ACSR Conductor Code name Specification standard to which the conductor manufactured and tested makers name and address Aluminium rods steel wire/ rods Complete conductors Standing and wire diameter Aluminium steel wire/ rods Standard nominal copper area in Sq. mm.

Page 70 of 72

CE(GSW)/SPV/BELAKAVADI

SOLAR PV POWER PLANT

SECTION-D TECH. PARTICULARS (TO BE FILLED BY THE TENDERER)

Sl. No. 6 7 8 9 10

Description To be furnished by the bidder Calculated equivalent Aluminium area in sq. mm. Actual Aluminium area in sq. mm. Standard area of cross section in sq. mm. Diameter of complete conductor in mm Max. D C resistance in ohms/KM at 20 Deg. C.

Page 71 of 72

CE(GSW)/SPV/BELAKAVADI

SOLAR PV POWER PLANT

SECTION-D TECH. PARTICULARS (TO BE FILLED BY THE TENDERER)

Sl. No.

Description To be furnished by the bidder Continuous max. current rating of 11(i) conductors in till air at 40 Deg C ambient temperature (ii) temperature of the above current 12 Standard length in each drum in mtrs. 11KV XLPE Cable Name of the manufacturer Make & Type Applicable standards Conductor material Nominal area of the conductor (in sq. mm.) Form of the conductor Nominal thickness of the insulation Nominal thickness of the inner sheath(mm) Nominal thickness of the outer sheath(mm) Type of armour Nominal diia of armour Approx. overall dia of cable Approx. weight of the finished cable Nominal delivery length(mm) Max D C resistance of conductor at 20 deg. C(ohm/Km) Approx. A C resistance of conductor at 90 Deg. C(ohm/Km) Approx. reactance at 50c/s Current rating Short circuit rating Approx. capacitance at 50Hz.(in micro F/km) Essential Spares List of spares-1 set ( as per section-D, Data Sheet)

XXX 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 XXXI

Page 72 of 72