1 - OPERATING GUIDE

1.11.1

Alarms with Critical severity


The following tables resumes all the alarms with Critical severity. The creation of the resuming signal of Critical alarm is different if the equipment is in protected configuration (Tab. 1.4) or in not protected one (Tab. 1.5).

Tab. 1.4 Event on Hardware key IDU

Alarms with Critical severity in protected configuration (1+1) H/S Code System Type Unknown Dis Mis Configuration Not Congruent with HW Card Fail Power Fail ASIC Fail I2C Fail ODU 1 DC ODU 2 DC SW Mismatch Download Failure LOF EBER TIM Description Alarm for System Type unknown (equipment temporary condition) IDU disconnected IDU mismatch Equipment configuration set via software not congruent with the requirements of the current System Type IDU fault Absence of the inner voltages ASIC circuit fail Fail on I2C inner communication bus Fail on the control circuit for the ODU 1 power supply Fail on the control circuit for the ODU 2 power supply FPGA software of the IDU not congruent with the hardware Error during the download of the FPGA software of the IDU Frame loss on aggregate signal High error degree (BER 10-3) on aggregate signal Error of link identification code (ID of received link different from the expected one) Absence of signal on tributary 1 . . Absence of signal on tributary 16 Presence of serious alarm on TX channel Presence of AIS on RX channel Root of the Card Fail alarm Root of the Card Fail alarm Root of the Card Fail alarm Root of the Card Fail alarm Root of the Card Fail alarm Root of the Card Fail alarm Root of the Card Fail alarm Notes

Trib 1 LOS . . Trib 16 LOS TX channel RX channel Tx On Line CH AIS Ins

1-144

SW COMMAND COLLECTION MW3649ENCCIT_0177 - February 2007

1 - OPERATING GUIDE

Tab. 1.5 Event on Hardware key IDU

Alarms with Critical severity in not protected configuration (1+0) Code System Type Unknown Dis Mis Configuration Not Congruent with HW Card Fail Power Fail ASIC Fail I2C Fail ODU DC SW Mismatch Download Failure LOF EBER TIM Description Alarm for System Type unknown (equipment temporary condition) Disconnected unit Mismatch unit Equipment configuration set via software not congruent with the requirements of the current System Type IDU fail Absence of the inner voltages ASIC circuit fail Fail on I2C inner communication bus Root of the Card Fail alarm Root of the Card Fail alarm Root of the Card Fail alarm Notes

Fail on the control circuit for the ODU power Root of the Card Fail supply alarm FPGA software of the IDU not congruent with the hardware Error during the download of the FPGA software of the IDU Frame loss on aggregate signal High error degree (BER 10-3) on aggregate signal Error of link identification code (ID of received link different from the expected one) Absence of signal on tributary 1 . . Absence of signal on tributary 16 Cable fail Interrupted/disconnected cable Overload on the cable Reception fail on the ODU Frame loss on aggregate signal at cable level High error degree (BER 10-3) on aggregate signal at cable level IDU - ODU path error (the IDU not detects the ODU) Root of the Card Fail alarm Root of the Card Fail alarm With IDU version A, only 8 tributaries are available (from 1 to 8) Root of the Card Fail alarm Root of the Card Fail alarm

Trib 1 LOS . . Trib 16 LOS I/F cable Cable Fail Open Cable Cable Overload FERF LOF EBER Path Fail

SW COMMAND COLLECTION MW3649ENCCIT_0177 - February 2007

1-145

1 - OPERATING GUIDE

Tab. 1.5 Event on ODU

Alarms with Critical severity in not protected configuration (1+0) Code Dis Mis ODU Power Fail ODU P Alarm Card Fail Power Supply I2C Fail IF Tx OL ODU mismatch Absence of the ODU power supply voltage (detected on the IDU) Fail for the ODU P ODU fail Absence of the ODU power supply voltage (detected on the ODU) Fail on I2C inner communication bus Fail of the local oscillator relevant to the IF TX section Fail of the local oscillator relevant to the IF RX section Modulator fail Root of the Card Fail alarm Root of the Card Fail alarm Root of the Card Fail alarm; available for ODU HD/HDe only Root of the Card Fail alarm; available for ODU HD/HDe only Root of the Card Fail alarm Description Disconnected ODU Notes

IF Rx OL

MOD Fail RF Tx OL RF Rx OL Tx Bias

Fail of the local oscillator relevant to the RF Root of the Card Fail TX section alarm Fail of the local oscillator relevant to the RF Root of the Card Fail RX section alarm Fail to the bias circuit of the TX section Root of the Card Fail alarm; available for ODU HD/HDe only Root of the Card Fail alarm

Tx Det RF LOS DEM Fail Freq Plan Fail TX channel RX channel Tx On Line CH AIS Ins

Fail to the RF transmitter Absence of the RF RX signal Demodulator fail Configuration error into the frequency plan Presence of serious alarm on the TX channel on service Presence of AIS on the RX channel

1-146

SW COMMAND COLLECTION MW3649ENCCIT_0177 - February 2007

1 - OPERATING GUIDE

1.11.2

Alarms with Major severity


The following tables resume all the alarms with Major severity. The creation of the resuming signal of Major alarm is different if the equipment is in protected configuration (Tab. 1.6) or in not protected one (Tab. 1.7).

Tab. 1.6 Event on Hardware key IDU

Alarms with Major severity in protected configuration (1+1) H/S Code Dis Mis ODU 1 HW Prot: Required ODU 2 HW Prot: Required Description Disconnected hardware key Hardware key mismatch Request of hardware protection of the ODU 1 for serious alarm Request of hardware protection of the ODU 2 for serious alarm Notes

Test of Periodic Timed Switching I/F 1 cable

ODU Stby Fail Alarm detected on the standby chain when During Periodic Test it is forced in service during the test Periodic Timed Switching Cable Fail Open Cable Cable Overload FERF LOF EBER Path Fail Cable fail Interrupted/disconnected cable Overload on cable Reception fail on the ODU Frame loss on aggregate signal at cable level High error degree (BER 10-3) on aggregate signal at cable level Error of IDU - ODU path (the IDU not detects the ODU) Cable fail Interrupted/disconnected cable Overload on cable Reception fail on the ODU Frame loss on aggregate signal at cable level High error degree (BER 10-3) on aggregate signal at cable level Error of IDU - ODU path (the IDU not detects the ODU) Root of the Card Fail alarm Root of the Card Fail alarm Root of the Card Fail alarm Root of the Card Fail alarm

I/F 2 cable

Cable Fail Open Cable Cable Overload FERF LOF EBER Path Fail

SW COMMAND COLLECTION MW3649ENCCIT_0177 - February 2007

1-147

1 - OPERATING GUIDE

Tab. 1.6 Event on ODU 1

Alarms with Major severity in protected configuration (1+1) H/S Code Dis Mis ODU Power Fail ODU P Alarm Card Fail Power Supply I2C Fail IF Tx OL ODU mismatch Absence of the ODU power supply voltage (detected on the IDU) Fail to the P of the ODU ODU fail Absence of the ODU power supply voltage (detected inside the ODU) Fail on I2C inner communication bus Fail on the local oscillator of the IF TX section Fail on the local oscillator of the IF RX section Modulator fail Fail on the local oscillator of the RF TX section Fail on the local oscillator of the RF RX section Fail to the bias circuit of the TX section Root of the Card Fail alarm Root of the Card Fail alarm Root of the Card Fail alarm; available for ODU HD/HDe only Root of the Card Fail alarm; available for ODU HD/HDe only Root of the Card Fail alarm Root of the Card Fail alarm Root of the Card Fail alarm Root of the Card Fail alarm; available for ODU HD/HDe only Root of the Card Fail alarm Description ODU Disconnected Notes

IF Rx OL

MOD Fail RF Tx OL RF Rx OL Tx Bias

Tx Det RF LOS DEM Fail Freq Plan Fail

Fail to the RF transmitter Absence of the RF RX signal Demodulator fail Configuration error into the frequency plan

1-148

SW COMMAND COLLECTION MW3649ENCCIT_0177 - February 2007

1 - OPERATING GUIDE

Tab. 1.6 Event on ODU 2

Alarms with Major severity in protected configuration (1+1) H/S Code Dis Mis ODU Power Fail ODU P Alarm Card Fail Power Supply I2C Fail IF Tx OL ODU mismatch Absence of the ODU power supply voltage (detected on the IDU) Fail to the P of the ODU ODU fail Absence of the ODU power supply voltage (detected inside the ODU) Fail on I2C inner communication bus Fail on the local oscillator of the IF TX section Fail on the local oscillator of the IF RX section Modulator fail Fail on the local oscillator of the RF TX section Fail on the local oscillator of the RF RX section Fail to the bias circuit of the TX section Root of the Card Fail alarm Root of the Card Fail alarm Root of the Card Fail alarm; available for ODU HD/HDe only Root of the Card Fail alarm; available for ODU HD/HDe only Root of the Card Fail alarm Root of the Card Fail alarm Root of the Card Fail alarm Root of the Card Fail alarm; available for ODU HD/HDe only Root of the Card Fail alarm Description ODU Disconnected Notes

IF Rx OL

MOD Fail RF Tx OL RF Rx OL Tx Bias

Tx Det RF LOS DEM Fail Freq Plan Fail Tab. 1.7 Event on Hardware key Dis Mis

Fail to the RF transmitter Absence of the RF RX signal Demodulator fail Configuration error into the frequency plan

Alarms with Major severity in not protected configuration (1+0) Code Description Disconnected hardware key Hardware key mismatch Notes

SW COMMAND COLLECTION MW3649ENCCIT_0177 - February 2007

1-149

1 - OPERATING GUIDE

1.11.3

Alarms with Minor severity


The following table resumes the alarms with Minor severity.

Tab. 1.8 Event on Hardware key Network interfaces F R D Embedded D channel SNTP synchronization

Alarms with Minor severity Code Key E2prom Fail Description Fail of the EEPROM Alarm for protocol error on F interface Alarm for protocol error on R interface Alarm for protocol error on D interface Frame loss on input embedded D channel Frame loss on output embedded D channel Notes

D-CH IN LOF D-CH OUT LOF

Time Server Missing Loss of synchronization with the Time Server

1-150

SW COMMAND COLLECTION MW3649ENCCIT_0177 - February 2007

1 - OPERATING GUIDE

1.11.4

Alarms with Warning severity


The following table resumes the alarms with Warning severity.

Tab. 1.9 Event on Hardware key ODU1

Alarms with Warning severity Code Alignment Fail SW Not Aligned Description Serial number of the hardware key different from the one saved into the Controller Version of the running software on the ODU different from the version present into the memory of the Controller Version of the running software on the ODU different from the version present into the memory of the Controller Version of the running software on the FPGA of IDU different from the version present into the memory of the Controller Condition of early warning high Condition of early warning low Block error on remote terminal Reception fail on remote terminal AIS presence at input on tributary 1 . . AIS presence at input on tributary 16 AIS presence at output on tributary 1 . . AIS presence at output on tributary 16 Error on tributary 1 . . Error on tributary 16 Alarm present on the stand-by chain before that it is forced in service during the Periodic Timed Switching test phase With IDU version A, only 8 tributaries are available (from 1 to 8) With IDU version A, only 8 tributaries are available (from 1 to 8) With IDU version A, only 8 tributaries are available (from 1 to 8) Notes

ODU 2 (not present in System Type (1+0)) IDU

SW Not Aligned

SW Not Aligned

EW High EW Low FEBE FERF Trib 1 AIS IN . . Trib 16 AIS IN Trib 1 AIS OUT . . Trib 16 AIS OUT Trib 1 Code . . Trib 16 Code Test of Periodic Timed Switching (not present in System Type (1+0)) Last test failed

1.11.5

Alarms with Indeterminate severity


Currently no alarm of Indeterminate severity is available for the equipment.

SW COMMAND COLLECTION MW3649ENCCIT_0177 - February 2007

1-151

1 - OPERATING GUIDE

1.11.6

Events with Test severity


The following table resumes the events with Test severity (events that activate the signaling of manual operation on progress).

Tab. 1.10 Event on Commissioning test for system 1

Events with Test severity Code Temporary System 1 OFF Description Temporary switching of system 1 Notes Temporary condition that automatically ends at the end of the set switching off period

ODU 1 CW Test Commissioning test for system 2 (not present in System Type (1+0)) Temporary System 2 OFF

Forcing of transmission of the not modulated carrier Temporary switching of system 2 Temporary condition that automatically ends at the end of the set switching off period

ODU 2 CW Test Test of Single Timed First/Second Forcing Period Switching (not present in System Type (1+0)) Test of Periodic Timed Switching (not present in System Type (1+0)) Forcing Period

Forcing of transmission of the not modulated carrier Period 1/2 of forcing of the hardware switch Temporary condition that automatically ends at the end of the set forcing period Temporary condition that automatically ends at the end of the set forcing period

Period of forcing of the standby channel of the hardware switch

Protection (1+1) H/S Manual Forced ODU (not present in System Type (1+0)) Test loop on the tributaries Trib 1 Local Loop . . Trib 16 Local Loop Trib 1 Rem. Loop . . Trib 16 Rem. Loop

Command of manual forcing of the protection hardware switch Local loop command on tributary 1 . . Local loop command on tributary 16 Remote loop command on tributary 1 . . Remote loop command on tributary 16 With IDU version A only eight tributaries are available (from 1 to 8)

1-152

SW COMMAND COLLECTION MW3649ENCCIT_0177 - February 2007