You are on page 1of 4

PROJECT:

ITEM NO.:

FOOD WASTE REDUCTION SYSTEM

PRODUCT FEATURES & SPECIFICATIONS


Up to 85% volume reduction Capacity 700 lbs (317.5 kg) of waste per hour Fits under standard table minimum height 34" (863.6 mm) Does not require cardboard Stainless steel construction Quick and easy to clean no tools required One year full warranty Processes 100% food waste or up to 50% disposables NEMA 4 stainless steel electrical control panel Removeable auger and screen Interlock on discharge chute Water usage 2-5 GPM (7.6-18.9 LPM) sink or bowl configuration Trough application contact factory

ELECTRICAL SPECIFICATIONS
208-230V, 60 Hz, 3 Ph, 7.7/9.4 amps (Disposer 6.0/7.4 amps, WX 1.7/2 amps) 460V, 60 Hz, 3 Ph, 4.7 amps (Disposer 3.7 amps, WX 1 amp)

DISPOSER MOUNTING ASSEMBLIES


#6 Collar Adaptor for welding into trough or sink, provides 6-5/8" (168.3 mm) opening, includes splash baffle 18" Type A Sink Bowl Assembly with two water nozzles, includes removable splash baffle and stainless bowl cover

ACCESSORIES
Trough Nozzle - 1" (25.4 mm) NPT WXP Inlet/Outlet Flange - 2" (50.8 mm) NPT (secondary) (Trough or high water flow applications) Dejamming Wrench
A complete collection of our product drawings is available for download at the InSinkErator Revit/CAD Library, which can be found at www.insinkerator.com/foodservice. Product information is also accessible on The KCL CADalog. More information is available from KCL at www.kclcad.com.
4700 21st STREET RACINE, WI 53406-5093 TEL: 800-845-8345 FAX: 262-554-3620

www.insinkerator.com
InSinkErator is a business unit of Emerson Electric Co.

The Emerson logo is a trademark and a service mark of Emerson Electric Co.

InSinkErator 2013Printed in USAForm No. F269-13K-89-85

SYSTEM COMPONENTS
This System Includes:
Waste Xpress Unit 3 HP Disposer Disposer mount (collar or bowl) Syphon Breaker Flow Control Valve 5 GPM (18.9 LPM) Magnetic Silver Saver 10 gallon (37.9 liter) Waste Can 3" (76.2 mm) to 2" (50.8 mm) disposer waste outlet reducer fitting (2) 24V Water Solenoids WX-101A Control Center

Items Supplied by Others:


Plumbing from cold water supply to bowl or trough Plumbing from hot water supply to Waste Xpress Plumbing from disposer to Waste Xpress or Waste Xpress to floor sink or floor drain Shut off valves Electrical connections

TYPICAL INSTALLATION

45 bend shown (max of 4 can be used)

Figure 1. Waste Xpress Top View

1-1/2" (38.1 mm)

3" (76.2 mm)

Syphon Breaker Sink Bowl Cold Water Solenoid Hot Water Solenoid Waste Xpress

1-1/2" min (38.1 mm min) Disposer

1" min (25.4 mm min)

Flow Control Valve

WX-101A Controller 10 max (3.1 m max)

Shut Off Valve (supplied by others)

Figure 2. Waste Xpress Typical Installation

GENERAL NOTES
Disposer
Install the disposer per the Instruction, Care and Use manual. When positioning disposer ensure that the overload reset button is accessible by end user. Connect cold water to either the sink bowl or end of trough. The Waste Xpress should be disassembled and cleaned a minimum of once daily. Interior of cabinet and discharge chute should be cleaned with hot soapy water. Auger, screen and bearing bracket can be cleaned either manually with hot soapy water or in a dishwasher.

Waste Xpress

Install the Waste Xpress per the Instruction, Care and Use manual. Position the pulper so that the front surface of the discharge chute is recessed 3" (76.2 mm) (see Figure 1) from the front edge of the table and that a minimum clearance of 1" (25.4 mm) exists between the underside of the table and top of the discharge chute (see Figure 2) for proper removal of discharge chute, ease of cleaning and general maintenance. Position the pulper so that it is within 10' (3.1 m) of the disposer outlet flange. (See Figure 2)

Control Panel

Install the WX-101A control panel per the Instruction, Care and Use manual and in accordance to local, state and or national electric codes. Position the control panel so that the front surface is recessed 1-1/2" (38.1 mm) from the front edge of the table and that a minimum clearance of 2" (50.8 mm) exists between the underside of the table and the top of the control panel for ease of installation and serviceability. Position the WX-101A control panel so that it is within site of the disposer and pulper.

PLUMBING NOTES
Waste Connection
2" (50.8 mm) NPT used between disposer, Waste Xpress and drain When connecting the drain line from the disposer to the Waste Xpress use a maximum of (4) 90 bends (45 bends are recommended) with a 1/4" (6.4 mm) drop per foot of run or as local codes apply. Floor sink or drains should be installed per local codes but kept clear of yet accessible to pulper. Trough applications in excess of 10' (3.1 m) and/or systems plumbed with a cold water supply greater than 7 GPM (26.5 LPM) must incorporate the second drain outlet from the pulper and be drained independently to floor sink or drain.

Fresh Water Connections

1/2" (12.7 mm) NPT used on syphon breaker, solenoid and flow control valve. 1/2" (12.7 mm) NOM compression used on sink bowl nozzles. 1/2" (12.7 mm) Ridged Copper (compression) used on hot water connection to pulper. If fresh water supply is greater than 50 psi (144.7 kPa), a pressure regulating valve must be installed in both. It is recommend that ball type shutoff valves be installed in the cold and hot water lines. It is recommended that the hot water connected between solenoid valve and pulper be terminated with a union for ease of serviceability.

TROUGH APPLICATION NOTES


Construction
The recommended maximum trough length is 10' (3.1 m). A silver saver should be fabricated prior to end of trough to catch utensils and dishes.

Magnet

Water Supply

Can be mounted to trough either by tack welding to using weld studs (see instruction sheet for weld stud pattern). Trough magnets should be placed within 12" (304.8 mm) of end of trough or trough intersection with sink bowl (see Figure 4). Additional magnets can be used as necessary.

For trough lengths of 10' (3.1 m) or less place water nozzle at end of trough. For trough lengths greater than 10' (3.1 m) place one water nozzle at end of trough and one mid stream. Do not plumb water to disposer grind chamber.

Trough Flow

Water Nozzle

Figure 3. Trough Typical Installation Top View

Connect Cold Water Supply to end of Trough

1" (25.4 mm) min, 3" (76.2 mm) max

1" min (25.4 mm min)

Recommended Magnet Location

Optional Magnet Location

Figure 4. Trough Typical Installation

DIMENSIONS
5-1/4" (133.4 mm)

2" (50.8 mm) NPT Outlet (Either Side) 15" (381 mm) 8-5/8" (219.1 mm)

2" (50.8 mm) NPT Inlet (Either Side)

9-7/8" (250.8 mm) 8-1/4" (209.6 mm)

18-3/4" (476.3 mm) 12-1/8" (308.0 mm)

15-1/8" (384.2 mm)

15-3/4" (400.1 mm) 14" (355.6 mm) 5-5/16" (134.9 mm) 6-3/4" (171.5 mm)

1-5/8" (41.3 mm)

1" (25.4 mm)

Waste Xpress Top View

27-3/8" (695.3 mm)

Leveling Foot Adjustment Range 2-3/4" (69.9 mm)

Waste Xpress Front View


1/2" (12.7 mm) Hot Water Inlet

Control Center Front View

Control Center Side View

8" (203.2 mm)

6-1/2" (165.1 mm)

7-7/8" (200.0 mm) 21-3/4" (552.5 mm) 14-1/2" (368.3 mm) 8-1/8" (206.4 mm) Electrical Connection Cover

33-1/2" (850.9 mm) 26-7/8" (682.6 mm) 21-1/8" (536.6 mm) 9-1/8" (231.8 mm)

13" (330.2 mm) 23-3/4" TO 31-1/8" (603.3 mm TO 790.6 mm)

External Electrical Connection Cover

2" (50.8 mm) NPT Outlet Adjustable Legs 8-3/4" (222.3 mm) 8-3/4" (222.3 mm)

1/2" (12.7 mm) Electrical Inlet

Waste Xpress Side View

Waste Xpress Back View

Disposer Front View

Disposer Side View

NOTE: All Waste Xpress height dimensions are max numbers. Leveling foot will allow height to be reduced up to 2-3/4" (69.9 mm).

PROJECT INFORMATION
Item Number: Quantity: Manufacturer: InSinkErator Project: Address: City/State/Zip: Contact: Phone: Model Number: Electrical Requirements:

volts

phase

Dealer: City/State/Zip: Contact: Phone:

Installer: Contact: Phone:

Consultant: Contact: Phone: