Catalogue

MDS-R410A-2008

MULTI DIGITAL SCROLL UNITS


MODEL: MDS050B(R)5-MDS500B(R)5 COOLING CAPACITY: 13.5kW-134kW HEATING CAPACITY: 15kW-148kW

Digital Variable Multi

For High Ambient Temperature Cooling

Engineered for flexibility and performance. TM

For More Than a Century, McQuay has been Devoted to

Different Buildings

Global headquarters of McQuay (Minneapolis, USA)

McQuay Staunton Factory, USA

McQuay Aubum Factory, USA

McQuay Cecchina Factory, Italy

McQuay Shenzhen Factory, China

Workshop of McQuay Shenzhen Factory, China

Test center of McQuay Shenzhen Factory, China

Sound test room of McQuay Shenzhen Factory, China

Research of Central Air Conditioning and Related Technologies

Unanimous Acclamation

For 130 years, we have been forging ahead at the forefront of HVAC technology, creating many firsts in the development history of air conditioning. For most household and commercial users, McQuay is the incarnation of quality and trustworthiness. Today, McQuay introduces leading-edge central air conditioning technology all over the world. With centurial expertise, we are providing end users with energy-saving, eco-friendly and comfortable air conditioning products.

McQuay Cramlington Factory, UK

McQuay Multi Digital Scroll High Temperature Series

Based on the success of MDS Variable Digital Multi system of normal temperature series, McQuay MDS BHC High ambient temperature series is a new generation of multi-scroll units. They ideally combine the cutting-edge digital technology with high adaptability of atrocious environment. In addition, this series features higher performance, higher capacity, lower sound, easier installation, and stronger system management, taking the lead in the market.

imple

oft

anitary

Page 

trong ave energy

ilence

Indoor Unit Line-up


Model MCC MCK MDB MCM MWM
Ceiling concealed units

Capacity range
0.8HP 1.0HP 1.5HP 1.8HP 2.0HP 2.5HP 3.0HP 4.0HP 5.0HP 6.0HP 8.0HP 10.0HP

18 20 22 24 26
Page 

Ceiling cassette units

High static pressure duct units

Ceiling exposed / floor standing units

Wall mounted units

Featuring Leading-edge Digital Technology


McQuay Multi Digital Scroll High Temperature Series

High adaptability to Wider Operation Range


Specially designed BHC series multi digital scroll units are suitable for high ambient temperature application up to 52. Enlarged condensing coil can effectively lower the discharge pressure and make the system run safely at high ambient temperature. Fan motor is designed for high ambient temperature running. Electrical parts are selected for high ambient operation. Exhaust fan can maintain the internal temperature inside the control box at an accepted level even under very high ambient temperature to make the controllers and electrical parts work properly. Fins are protected by a special paint in gold color to give better protection against corrosion in aggressive environment.

Exhaust fan in control cabinet.

High EER
MDS100B system

100%

An optimization cooling-circuit design makes the unit more efficient. Take MDS120BHC for example: it's EER is up to 3.5 (35 cooling condition at full load), which is much higher than Normal styling.
5%

operating

operating Loading

operating Unloading

Page 6

trong

MDS digital variable multi BHC series units feature stronger cooling performance in high ambient temperature, stepless capacity modulation and accurate temperature control, thus making your space more comfortable.

Superior Cooling & Heating Performance


Specially designed MDS digital variable multi BHC series feature leading-edge unit design and superior heating performance. They have undergone strict system match and performance test, and work well in anbient temperature as high as 52. 52

Quick Achieving the Set Temperature


In MDS digital variable multi systems, heat transter is happened directly between the refrigerant and air. And equipped with a smart temperature controller, the unit can achieve the set temperature quickly. Also the indoor temperature fluctuates very little, making your room more comfortable.
Traditional air conditioners MDS digital variable multi system

Initial temp.: 30

Set temp.: 25

Wider Capacity Modulation Range


The compressor of MDS digital variable multi systems feature 10% ~ 100% stepless capacity modulation range. Thanks to this, the unit can provide cooling/heating capacity exactly as required. Compared with traditional invert systems (step output), MDS digital variable multi systems feature wider capacity modulation range, and save more energy.
Taking 10HP units for example

Cooling capacity %

MDS digital variable capacity system

Variable frequency system

Capacity %

Page 7

Featuring Leading-edge Digital Technology


McQuay Multi Digital Scroll High Temperature Series

ave energy
High EER

MDS digital variable multi systems feature leading-edge digital capacity modulation design, thus saving more energy and reducing electricity cost.

MDS BHC units feature leading-edge system design and higher EER, thus saving more energy compared with traditional air conditioners. For most time around the year, air conditioners work at a partial load. Seasonal EER is the main index for judging whether the unit is more energy-efficient. MDS digital variable multi systems feature high EER at full capacity, and even higher EER at partial capacity. Thanks to this, they can save more energy and effectively reduce the electricity cost. Digital stepless capacity modulation with a wider range Less on/off operations and smaller startup current 5% ~ 20% less capacity modulation loss compared with invert systems When the digital compressor is unloaded, the power of the unit is reduced to 10% of the full load power. No invert loss, thus reducing power consumption While working at partial load, the outdoor unit supplies heating/cooling capacity to the indoor units exactly as necessary, thus eliminating bypass power consumption.
Capacity modulation controller Digital compressor AC DC Capacity controller AC

AC

PWM valve control

AC

Converter

DC

DC

Transducer

Variable frequency

Compressor

Modulation loss = 0%

Modulation loss = 10%

Motor loss = 5 ~ 10%

MDS digital variable multi system

Traditional invert system

Energy Saving and Cost Effective


MDS digital variable multi systems feature high seasonal EER. They can achieve better heating and cooling performance with less power consumption. Compared with traditional systems, MDS digital variable multi systems can save up to 45% electricity cost.

Traditional central air conditioning system

Digital variable capacity system

Page 

oft

MDS digital variable multi systems ideally integrate leading-edge air handling technology, accurate temperature control technology and reliable smart multi-scroll technology. They are designed to make your room more comfortable and fresh.

Accurate Temperature Control and Quick Response


The capacity requirement for air conditioners changes according to lots of factors, such as ambient temperature and sunshine. Therefore, it would be much better if the air conditioners feature stepless capacity modulation and quick response. Otherwise, the temperature fluctuations will make people feel uncomfortable.The brand new MDS digital variable multi systems feature stepless capacity modulation, and can change output capacity instantly. Therefore, they can provide cooling/heating capacity as required. Whats more, accurate temperature control also makes your room more comfortable.
Temperature
Temperature fluctuation of traditional household air-conditioners: 2 C Temperature fluctuation of traditional variable frequency system: 0.5C Temperature fluctuation of MDS digital variable capacity system: 0.3 C

Time

Dry bulb temperature control can be as accurate as 0.3 Unique and dynamic load forecast technology Leading-edge and continuous load tracing technology Quick capacity modulation: instantly changing from 10% to 100% The electronic expansion valve is quick in response, thus making temperature control more accurate and reducing the time needed to achieve the set temperature.

Excellent Dehumidification Performance


In hot and wet days, the humidity of indoor air increases sharply, thus making people feel very uncomfortable. MDS digital variable multi systems feature better dehumidification performance. Even during the hot and wet rain season, they can make your room comfortable and brisk. MDS digital variable multi systems work at a lower sensible heat ratio. The suction pressure is lower than that of VRV systems. Therefore, they feature stronger dehumidification performance.
Environment Temperature () Variable frequency system MDS digital variable capacity system

Cooling capacity (kW) Note: take MDS100BHC for example

Page 9

Featuring Leading-edge Digital Technology


McQuay Multi Digital Scroll High Temperature Series

Reliable and Leading-edge One for More Technology


MDS digital variable multi systems feature advanced One for More technology. One outdoor unit can connect up to 32 indoor units. Therefore, the number of outdoor units can be greatly reduced, and the appearance of the building will not be degraded by installing air conditioners.

Multi-types and Flexibility


The indoor units feature multiple types. They suit well with modern household upholstery. If your room is perfectly upholstered, they will make perfection still more perfect. The indoor units use the air outlet of large central air conditioning system. In this way, they facilitate indoor upholstery. For indoor units, various capacities from 0.8 HP to 10 HP are available.
Indoor unit model Indoor unit capacity

MCK

0.8HP

MDB

MCC

MCM MWM 10HP

Page 10

oft
Excellent Electromagnetic Compatibility
While modulating capacity, MDS digital variable multi systems only shift precision parts, and produce no high frequency harmonic wave. Therefore, they will not destroy with high fidelity sound boxes, computers, telephones etc. They can be widely used in places where interference with the power supply must be strictly prohibited, such as computer rooms, telecom base stations, TV broadcast reception stations and telecom equipment rooms.

High frequency harmonic wave

MDS digital variable capacity system EMC regulations Variable frequency system

EMC comparison diagram

As the frequency signal changes, high frequency systems will generate high frequency harmonic waves with frequencies 5, 7, 11, 13, 17 19 times as high as that of the power supply. As a result, the power factor of the electricity network is reduced, the capacitor and transformer overheat, flashing points appear at the fluoroscopes and oscillographs, and the precision of precision instruments are lowered.The electromagnetic interference (EMI) of invert systems are now internationally deemed as an environmental pollution. The electricity cost spent on suppressing EMI also makes users sweat.

Page 11

Featuring Leading-edge Digital Technology


McQuay Multi Digital Scroll High Temperature Series

anitary

MDS digital variable multi systems feature leading-edge air purification technology. They can dampen the breeding of bacteria and improve air quality, thus making your room more sanitary and comfortable.

Fresh Air Replacing


Each room can be equipped with an independent fresh air processing unit, and takes in fresh air freely. In this way, it improves the indoor air quality and makes your room more comfortable. You can breathe in fresh air right inside your room. Optional HRB heat recycling units facilitate both fresh air suction and energy saving.
Fresh air Air supply Return air Note: The above pipelining only serves as an example. For MCK pipelining, please refer to the manual.

Dampening the Breeding of Bacteria


Scientific research shows the breeding of bacteria increases as the air humidity increases.MDS digital variable multi systems feature excellent dehumidification performance. Therefore, they can effectively dampen the breeding of bacteria, and prevent articles from going moldy. In this way, they can prevent the indoor air from being polluted, and greatly improve indoor air quality.

Excellent Disinfection Performance


You can choose to equip ceiling concealed units with air filters manufactured by McQuays brother company AAF (American Ail Filter). Such air filters contain the disinfectant lNTERSEPT. Research shows that they can effectively dampen the breeding of organisms, and improve indoor air quality (IAQ).

Page 12

ilence

MDS digital variable multi systems feature leading-edge sound absorbing technology, and operate more quietly.

Using a new type of spiral blades, the outdoor unit features smooth air draft structure, significantly reducing the turbulent flow and lowering the airflow sound level.

New type of spiral blades

V heat exchanger

Sound-insulation design for the compressor

Based on state-level sound test room and frequency analysis, all parts such as fans and motors are carefully compared, improved and chosen. The structure and pipeline also feature professional sound absorbing design, significantly reducing the sound level of the unit.

State-level precision sound test room

Sound frequency analysis

Innovative night silence mode (cooling) for the outdoor unit can automatically modulate the fan speed as the ambient temperature changes. Therefore, the unit can work more quietly and save more energy.

MDS digital variable multi systems can work more smoothly and quietly

Page 13

Featuring Leading-edge Digital Technology


McQuay Multi Digital Scroll High Temperature Series

imple

The MDS system are simple and reliable, the design and installation are more flexible.

The outdoor unit of MDS system is designed as package, the compact structure occupies less space and is easy to move. The outlines and dimensions of the innovated units are compact. They can be installed side by side to save space.

MDS system is designed to a capacity modulation system without oil circle. Piping length between outdoor unit and indoor unit can be extended up to 150 meters. The heighr between outdoor unit and indoor unit can be extended up to 50 meters when the outdoor unit is above the indooe unit. (If the outdoor unit is below the indoor unit, the height between them can be up to 40 meters.) The height between different indoor units can be extended up to 15 meters, which enables a single system to cover 4 or 5 floors. For different model condensing unit, factory recommends the different limit. The left drawing is just for your reference.

The outdoor units can be located on the rooftop, which saves space and is convenient for installation. The depth and height of all the units are the same. When they are located together, they look elegant.

Only the refrigerant pipe is needed for MDS system, which can save you a lot of money because there is no chilled water piping and other accessories.

The refnet joint is provided by the factory in accordance with different indooe units, which will reduce the work force at site and save a lot of money.

Page 14

McQuay Simple Software Management System


Central Control
MDS system can be connected up to 32 indoor units. 32 outdoor units can be controlled in a network through a centralized controller. The monitor software can monitor 1024 (32x32) indoor units in real time at the same time. The communication cables between indoor units and outdoor units are very easy to arrange. MDS system has a strong function of displaying the malfunction, which can save maintenance time and cost.

MDS

MDS system real time control interface

MDS

Capable of monitoring 1024 (32x32) indoor units simultaneously in real time

Dongle Key

Reliable
MDS system adopts the advantaged capacity modulation technology to reduce the control devices, which reduce the malfunction odds mostly. MDS system has excellent oil return performance even at low capacities, which will make sure that all of the removable parts of the compressor can be lubricated and cooled down. Thus, the compressor remains reliable throughout operation. It reduces the start/stop times, which will reduce the attack to the electricity supply net. The PWM (Pulse Width Modulation) valve has the longevity of 40 million times. The design is simple and there is no requirement for bypass valve.

Wired control + Remote control

Remote control

Central control

Page 15

Featuring Leading-edge Digital Technology


McQuay Multi Digital Scroll High Temperature Series

McQuay Software Management System


Real-time Monitor
System monitor software: Powerful MDS real-time monitor software can implement indoor control, system control, circuit control and service control. It helps users or serving personnel to view detailed parameters and unit data. Description of main control functions:

Indoor Monitoring
Set the mode, fan speed, auxiliary setting, and temperature of indoor units. Switch on/off indoor units.(You can operate several units or several machines in several units at the same time.) Set indoor units and outdoor units in groups. You can customize the group settings. (The default groups are by outdoor units.) Display alarms and check alarms. (You can check malfunction of outdoor or indoor units by selecting numbers.) Set timing mode and set the timing mode of indoor units. (You can set and save the timing mode of the units without any limitation.)

System Monitoring
Display the types and status of all the indoor units in the system, including alarm and timing. Description of icons of each type:
TYPE MCC MCK MDB Icon
Switching off Cooling Heating Dehumidifying Ventilating

Description of icons of indoor units:


Small icon The timing function of this indoor Description enabled unit is The wired controller of this indoor unit is locked. You cannot control it through the cable controller. Faults occur to this indoor unit. Double-click this icon to view the details.

Circuit Monitoring*
Select and view the system diagram, running parameters of outdoor units, and running parameters of all the indoor units.

Service Monitoring*
The current running parameters and the curves of history records of outdoor and indoor units can be displayed.

Note: * Only authorized maintenance personnel can use this window.

Page 16

Flexible and Convenient Selection Software


The selection software designed for different models allows you to select and verify unit models as required by customers, and determine the models of indoor and outdoor units as well as the required quantity of refnet joints and pipes. Thus, the selection software enables you to carry out complex unit design and selection more easily and quickly with a single click.

Page 17

Featuring Leading-edge Digital Technology


McQuay Multi Digital Scroll High Temperature Series

Ceiling Concealed MCC Series Indoor Units


The design of McQuay ceiling concealed indoor units takes into account the space module, small partition and other features of modern commercial buildings. Cooled/heated air is supplied to all parts of the room evenly, causing no indoor temperature difference. The units also timely refill the room with fresh air, thus completely eliminating air conditioning related harm. Whats more, the air conditioner and air duct are concealed and match well with the indoor upholstery, thus saving space and facilitating installation.

Auto dehumidification

Auto failure detection

Leak-proof drain pan

Taking in outdoor fresh air

Wireless remote (optional)

Air flow modulation

Silence mode

Anti-mildew filter

Timed on/off

Auto restart after power failure (optional)

Features
Miniaturized central air conditioner Similar to large central air conditioners, the indoor units and air duct are installed inside the ceiling and takes up no additional space. Therefore, they match well with the indoor upholstery. Optional ESP To supply conditioned air over different distances, various static pressure levels are applied to units according to their cooling capacities. To change the static pressure, you just need to change the motor connection wire.

Intelligent control The control system features microprocessor wire controller and LCD display, and provides several operation modes for you to choose from.

Quiet operation The centrifugal fan of the indoor unit features wide and efficient blades, and forward curved double suction. The fan rotates slower, and produces less sound. However, it generates stronger air flow.

Optional Super thin The indoor unit is as thin as 250 mm (220mm for MCC008T-015T) upholstery cost. Concealed installation saves both space and upholstery cost. The air supply outlet matches perfectly with the indoor upholstery, and makes your room more beautiful. Easier to installation The left and right connection pipes can be exchanged (for MCC008T-020T). A condensate pump with lift up to 500 mm is also available. Therefore, installation becomes much easier.

Right connection pipe

Left connection pipe

Page 18

Ceiling concealed indoor units


Model Nominal cooling capacity Power supply Rated power input Net weight Unit dimension (WxDxH) Air flow (H/M/L) Sound level (H/M/L) External static pressure Filter Liquid pipe Gas pipe Drain pipe mm(in) mm(in) mm(in) 6.35(1/4) 9.52(3/8) 12.7(1/2) 15.88(5/8) 19.05(3/4) kW Btu/h V/Ph/Hz kW kg mm m3/h CFM dB(A) Pa 0.047 22 0.047 22 1054469220 460/370/280 255/218/165 31/29/27 580/470/380 341277/224 34/32/30 15(0/30/50) Nylon 9.52(3/8) 19.05(3/4) 800/650/540 471/383/318 35/32/29 0.081 22 0.082 25 MCC008T MCC010T 2.0 6830 2.5 8540 MCC015T 3.65 12470 MCC018T MCC020T 4.5 15370 5.6 19130 MCC025T 6.5 22200 MCC030T 7.8 26640 MCC040T MCC050T 10.6 36200 12.4 42350 MCC060T 14.4 49180

220 - 240 / 1 / 50 0.082 25 0.123 27 1314490251 960/780/600 1200/950/800 565/459/353 37/36/35 706/559/471 42/40/38 30(15/50/70) 0.158 28 0.276 39 0.276 39 0.28 45 1924490251 2100/1750/1460 1236/1030/859 48/46/44

1664490251 1900/1520/1300 1118/895/765 47/45/43

50(15/30/70)

Notes: 1) All specification are subjected to change by the manufacturer without prior notice. 2) Nominal cooling capacity is based on 27DB, 19WB indoor temp. and 35DB outdoor temp. 3) The external static pressure data in bracket are adjustable, they can be achieved by changing the connectors inside the junction box. 4) Sound level are measured in an 11.5dBA background sound level anechoic chamber for units without return air plenum.

Page 19

Featuring Leading-edge Digital Technology


McQuay Multi Digital Scroll High Temperature Series

Ceiling Cassette MCK Series Indoor Units


When the ceiling cassette MCK series indoor units are installed, you can only see the panel. Cooled/heated air is supplied evenly in four directions, making modern apartments and offices more comfortable.

Auto dehumidification

Auto failure detection

Wireless remote

Leak-proof drain pan

Taking in outdoor fresh air

Auto swing

Air flow modulation

Silence mode Anti-mildew filter

Timed on/off

Prevent the Auto restart after ceiling from being power failure polluted (optional)

Features
Handsome appearance Trendy appearance design matches well with indoor upholstery, and adds more grace to your room. Microprocessor control Using a smart wireless remote, you can set the working mode, the fan speed, the on/off time etc. The unit also features accurate temperature control and energy saving, making your room more comfortable.

Low operation sound With leading-edge 3-D spiral blades and optimized air duct design, the unit operates with very little sound

Taking in outdoor fresh air The unit takes in more fresh air, making the air in your room fresh and healthy. Therefore, air conditioning related syndromes are completely eliminated.

Washable anti-mildew filter The filter can be easily and conveniently washed. It keeps the indoor air fresh and clean. Meanwhile, it can also get rid of unfavorable smells by using absorbent material.
Washable anti-mildew filter

Smooth water drainage Built-in automatic high-pressure condensate pump can pump out water up to 500mm high.The filter is optional.

500mm

Page 20

Ceiling cassette indoor units


Model Nominal cooling capacity Power supply Rated power input Net weight (with panel) Unit dimension (WxDxH) (with panel) Air flow (H/M/L) Sound level (H/M/L) External static pressure Liquid pipe Gas pipe Drain pipe kW Btu/h V/Ph/Hz kW kg mm m3/h CFM dB(A) Pa mm(in) mm(in) mm(in) 6.35(1/4) 9.52(3/8) 12.7(1/2) 15.88(5/8) 20.5(4/5) 0.028 26 (34) 0.029 0.040 30 (38) 0.043 MCK010T 2.8 9560 MCK015T 3.6 12290 MCK018T 4.5 15370 MCK020T 5.4 18440 MCK025T 6.5 22200 MCK030T 7.5 25610 MCK040T 10.0 34150 MCK050T 12.5 42690 MCK060T 14.0 47810

220 - 240 / 1 / 50 0.075 0.084 0.110 39.5 (47.5) 905905335 (930930363) 1800/1500/1350 1059/883/795 48/45/42 0.140 0.155

905905250 (930930278)

500/400/330 590/490/430 670/560/490 720/610/520 1200/1100/960 1300/1060/850 1360/1200/1110 1650/1450/1350 294/235/194 347/288/253 394/330/288 424/359/306 32/28/24 34/29/26 37/32/29 39/35/31 706/645/565 42/40/38 0 9.52(3/8) 19.05(3/4) 765/624/500 45/43/41 800/706/653 45/43/41 971/853/795 46/44/42

Notes: 1) All specification are subjected to change by the manufacturer without prior notice. 2) Nominal cooling capacity is based on 27DB, 19WB indoor temp. and 35DB outdoor temp. 3) Sound level are measured in an 11.5dBA background sound level anechoic chamber.

Page 21

Featuring Leading-edge Digital Technology


McQuay Multi Digital Scroll High Temperature Series

High Static Pressure Duct MDB Series Indoor Units


The design of McQuay High static pressure duct MDB series indoor units takes into account the space module, small partition and other features of modern commercial buildings. Cooled/heated air is supplied to all parts of the room evenly, causing no indoor temperature difference. The units also timely refill the room with fresh air, thus completely eliminating air conditioning related harm. Whats more, the air conditioner and air duct are concealed and match well with the indoor upholstery, thus saving space and facilitating installation.

Auto dehumidification

Auto failure detection

Leak-proof drain pan

Taking in outdoor fresh air

Wireless remote (optional)

Air flow modulation

Silence mode

Anti-mildew filter

Timed on/off

Auto restart after power failure (optional)

Features
Unique design The unique design makes the pipes easy to connect. Since the flange of the air outlet is tightly arranged in the bottom, the Gas pipes can be easily installed in the ceiling. It makes the mounting less demanding in terms of room height and reduces the construction cost. Taking in fresh air The unit uses an anti-mildew filter, and takes in enough fresh air to meet health requirements.

Graceful installation Similar to large central air conditioners, the indoor units and air duct are installed inside the ceiling. When the indoor units are installed, you can only see the air outlets. Therefore, they match well with the indoor upholstery and add more grace to your room.

Super thin The indoor unit is as thin as 350 mm, and is easy to mount on the ceiling. In this way, it saves space and building

Graceful installation The unit is ceiling mounted and matches well with the indoor upholstery. High static pressure also ensures that conditioned air can be supplied over a long distance.

Comfortable air supply The unit supplies cooled (heated) air to all parts of the room. The air outlet can be either downward or sideways. The air flow is both even and comfortable.

Bottom air supply Side air supply

Page 22

High static prssure duct indoor units


Model Nominal cooling capacity Power supply Rated power input Unit dimension (WxDxH) Air flow (H/M/L) Sound level (H/M/L) External static pressure Air outlet dimension Air inlet dimension Net weight Liquid pipe Gas pipe Drain pipe kW Btu/h V/Ph/Hz kW mm m3/h CFM dB(A) Pa mm mm kg mm(in) mm(in) mm(in) 286998 302957 69 9.52(3/8) 19.05(3/4) 20.5(4/5) 0.615 1230910350 2550/2040/1650 1501/1201/971 48/46/44 MDB050T 12.5 42690 MDB060T 1.4 47810 220 - 240 / 1 / 50 0.789 1430910350 3000/2540/1920 1766/1495/1130 50/48/46 100 2861198 3021157 75 264912 3881400 100 12.7(1/2) 28.6(1-1/8) 1.700 1690879420 4200/3740/3000 2470/2211/1769 57/55/52 MDB080T 2.24 76451 MDB100T 2.8 95563 380 - 415 / 3 / 50 1.480 16901020520 5000 2940 57 150 295749 4711402 150

Notes: 1) All specification are subjected to change by the manufacturer without prior notice. 2) Nominal cooling capacity is based on 27DB, 19WB indoor temp. and 35DB outdoor temp. 3) Sound level are measured in an 11.5dBA background sound level anechoic chamber.

Page 23

Featuring Leading-edge Digital Technology


McQuay Multi Digital Scroll High Temperature Series

Ceiling-exposed/Floor Standing MCM Series Indoor Units


Common air conditioners supply air in a single direction, making indoor temperature uneven and causing air conditioner related syndromes. McQuay Ceiling-exposed/floor standing MCM series indoor units feature smart dual outlet air supply, making air supply more comfortable.With dual air outlets, wider and even air supply, units of this series make the indoor temperature even and more comfortable.

Auto dehumidification

Auto failure detection

Wireless remote

Leak-proof drain pan

Auto swing

Air flow modulation

Silence mode

Anti-mildew filter

Timed on/off

Auto restart after power failure (optional)

Features
Handsome appearance The new type super thin design matches well with various upholstery styles, and adds more grace to your room. Manual/auto control over air supply direction The wind scooper can swing downwards and upwards to achieve the best air supply effect. You can also choose the air supply direction according to your own specific needs.

Innovative dual air outlet design The unit can supply air both horizontally and downwards. The wider air-supplying range makes the temperature and air flow more evenly distributed

Washable anti-mildew filter The filter can be easily and conveniently washed. It keeps the indoor air fresh and clean.

Ceiling mounted/floor standing The unit can be mounted either on the ceiling or on the floor, making it both economic and space saving.To mount the unit on the ceiling, you do not need to specially refit the ceiling. To mount the unit on the floor, you do not need to install a pedestal. Therefore, the unit features easy installation. While purchasing the unit, you need to specify the mounting type.

Easy maintenance/control Using a smart wireless remote, you can set the working mode, the fan speed, the on/off time etc. The unit also features accurate temperature control and energy saving, making your room more comfortable. To maintain and replace the air filter and electronic parts, you just need to open the return air grid.

Page 24

Ceiling mounted and floor standing indoor units


Model Nominal cooling capacity Power supply Rated power input Net weight Unit dimension (WxDxH) Air flow (H/M/L) Sound level (H/M/L) External static pressure Liquid pipe Gas pipe Drain pipe kW Btu/h V/Ph/Hz kW kg mm m3/h CFM dB(A) Pa mm(in) mm(in) mm(in) 15.88(5/8) 0.081 39 1214670214 1100/970/750 647/571/441 48/45/42 MCM020T 5.8 19810 MCM030T 7.5 25610 220 - 240 / 1 / 50 0.116 44 1214670249 1300/1100/870 765/647/512 50/46/43 0 9.52(3/8) 15.88(5/8) 20.5(4/5) 19.05(3/4) 0.161 64 1714670249 1850/1550/1200 1089/912/706 52/48/44 MCM050T 12.5 42690

Notes: 1) All specification are subjected to change by the manufacturer without prior notice. 2) Nominal cooling capacity is based on 27DB, 19WB indoor temp. and 35DB outdoor temp. 3) Sound level are measured in an 11.5dBA background sound level anechoic chamber.

Page 25

Featuring Leading-edge Digital Technology


McQuay Multi Digital Scroll High Temperature Series

Wall-mounted MWM Series Indoor Units


Wall-mounted MWM series indoor units are handsome in appearance.They feature air swing design. The wind scooper swings up and down to supply air evenly and comfortably into every part of the room.A smart wireless remote greatly facilitates control operations.

Auto dehumidification

Auto failure detection

Wireless remote

Leak-proof drain pan

Auto swing

Air flow modulation

Silence mode

Anti-mildew filter

Timed on/off

Auto restart after power failure (optional)

Features
Handsome appearance The new type super thin design matches well with various upholstery styles, and adds more grace to your room. Manual/auto control over air supply direction The wind scooper can swing up and down to achieve the best air supply effect. You can also choose the air supply direction according to your own specific needs.

Flexible installation The unit is thin and easy to install. MWM008T~015T series units are as thin as 198mm.

Washable anti-mildew filter The filter can be easily and conveniently washed. It keeps the indoor air fresh and clean.

198mm

Easy to control Using a smart wireless remote, you can set the working mode, the fan speed, the on/off time etc. The unit also features accurate temperature control and energy saving, making your room more comfortable.

Easy maintenance All kinds of maintenance work can be done from the front. The horizontal baffle can be easily removed and washed.

Page 26

Wall mounted indoor units


Model Nominal cooling capacity Power supply Rated power input Net weight Unit dimension (WxDxH) Air flow (H/M/L) Sound level (H/M/L) External static pressure Liquid pipe Gas pipe Drain pipe kW Btu/h V/Ph/Hz kW kg mm m3/h CFM dB(A) Pa mm(in) mm(in) mm 6.35(1/4) 9.52(3/8) 6.35(1/4) 9.52(3/8) 16.5 0.024 10 799198260 460/330/270 271/194/159 39/34/28 0.036 12 899198260 510/420/320 300/247/188 39/34/28 590/500/370 347/294/218 42/36/29 0 6.35(1/4) 12.7(1/2) 6.35(1/4) 15.88(5/8) 20.5 9.52(3/8) 15.88(5/8) MWM008T 2.2 7510 MWM010T 2.78 9490 MWM015T 3.52 12020 220 - 240 / 1 / 50 0.040 12 0.048 16 1062222304 860/720/590 506424/347 44/40/35 1100/790/680 647465/400 49/43/40 0.068 16 MWM020T 5.4 18440 MCM025T 6.5 22200

Notes: 1) All specification are subjected to change by the manufacturer without prior notice. 2) Nominal cooling capacity is based on 27DB, 19WB indoor temp. and 35DB outdoor temp. 3) Sound level are measured in an 11.5dBA background sound level anechoic chamber.

Page 27

Featuring Leading-edge Digital Technology


McQuay Multi Digital Scroll High Temperature Series

Outdoor Unit Specifications

8HP-14HP

16HP-28HP

Model Nominal cooling capacity


(1)

MDS080BHC kW Btu/h kW Btu/h kW kW V/Ph/Hz m3/h CFM dB(A) kg mm mm(in) mm(in) 22.4 76500 22.4 76500 6.4 9.0 11000/5800 6474/3414 60/54 280

MDS100BHC 28.0 95600 26.6 90800 8.5 10.2 12500/7300 7357/4297 62/55 285

MDS120BHC 33.6 114700 30.4 103800 9.6 11.8 12000/6400 7063/3767 61/56 320

MDS140BHC 39.2 133800 35.6 121500 11.9 14.4 380 - 415 / 3 / 50 13500/8000 7946/4709 63/57 355

MDS160BHC 44.8 152900 41.5 141600 12.8 16.2 22000/11600 12949/6828 60/55 515

MDS180BHC 50.4 172000 44.8 152900 14.6 18.2 22000/11600 12949/6828 60/55 520 19908401840

MDS200BHC 56.0 191200 51.5 175800 17.2 21.5 25000/14600 14715/8593 64/58 560 19.05(3/4) 38.1(1-1/2)

Nominal cooling capacity (2) Rated power input(1) Rated power input(2) Power supply Air flow (High/Low) Sound level(High/Low) Net weight Dimension(WxDxH) Liquid pipe Gas pipe Liquid pipe connection type Gas pipe connection type Refrigerant type Max. indoor quantity

9908401840 12.7(1/2) 28.6(1-1/8)

12908401840 15.88(5/8) 34.9(1-3/8) Flare Brazed flange R22

13

16

20

24

Model Combination Nominal cooling capacity (1) Nominal cooling capacity (2) Rated power input(1) Rated power input(2) Power supply Air flow (High/Low)) Sound level(High/Low) Net weight Dimension(WxDxH) Liquid pipe Gas pipe Liquid pipe connection type Gas pipe connection type Refrigerant type Max. indoor quantity kW Btu/h kW Btu/h kW kW V/Ph/Hz m3/h CFM dB(A) kg mm mm(in) mm(in)

MDS220BHC MDS120BMHC+ MDS100BSHC 61.6 210300 57.0 194500 18.1 22.0 24500/13700 14420/8064 63/57 605 22908401840

MDS240BHC MDS140BMHC+ MDS100BSHC 67.2 229400 62.2 212300 20.4 24.6 380 - 415 / 3 / 50 26000/15300 15303/9005 64/58 640 19.05(3/4)

MDS260BHC MDS120BMHC+ MDS140BSHC 72.8 248500 66.0 225300 21.5 26.2 25500/14400 15009/8476 64/58 675 25908401840 41.3(1-5/8) Flare Brazed flange R22

MDS280BHC MDS140BMHC+ MDS140BSHC 78.4 267600 71.2 243000 23.8 28.8 27000/16000 15892/9417 65/59 710

38.1(1-1/2)

24

32

Notes: 1) All specification are subjected to change by the manufacturer without prior notice. 2) (1) Cooling condition: Indoor D/W bulb Temp. 27/19,outdoor temperature: D bulb Temp.35; 3) (2) Cooling condition: Indoor D/W bulb Temp. 27/19,outdoor temperature: D bulb Temp.46; 4) The sound levels above are obtained in a semi-anechoic room with a background sound of 11.5dB(A). Depending on ambient sound or other factors, the actual sound level may vary.

Page 28

Accessories
Type Electronic expansion valve box Model Name Picture Units Remark

MEX

MCC, MCK, MCM, MWM indoor units

Standard

Wireless Remote controller

G4

MCM, MCK, MWM indoor units

Standard

Wired controller

MC301

MCC, MDB indoor units

Standard

Remote controller

AC5300

Working with the wired controller

Optional

Central controller

MC-CCS02B

All

Optional

Refnet joint

MDS-Yl

All

Optional

Refnet joint (with insulation)

MDS-YI-A

All

Optional

Twisted-pair

NA

All

Optional

Central control software

MC-CCS01A

All

Optional

Note: There are two types of refnet joint, Y-typeandC-type. We strongly recommend that the customer select the refnet joint provided by the factory. If other brands refnet joint is selected, it may result in bad effects to the system.
Page 29

Literature No.: CA-MDS(BHC)-0812A Supersedes: Nothing Part No.: M08039130008

2008 McQuay International

+1 (800) 432-1342

www.mcquay.com

While utmost care is taken in ensuring that all details in the publication are correct at the time of going to press, we are constantly striving for improvement and therefore reserve the right to alter model specifications and equipment without notice. Details of specifications and equipment are also subject to change to suit local conditions and requirements and not all models are available in every market.