Item

Description Unit Quantity BILL NO.2 ROADS, CARPARKS AND KERBS(PROVISIONAL) RESURFACING OF EXISTING ROAD PAVEMENT

Rate

Amount (RM)

Prepare and apply on layer of bituminous tack coat as described applied at a rate to be approved by the S.O. 40mm Thick premix wearing course as specified spread, levelled and rolled to required gradients, falls and chambers with approved roller.

M NEW PREMIX ROAD AND CARPARKS C Excavate for road commencing at reduced level average 500 mm deep, get out , part return, fill in, cart away from site as directed including trimming , levelling, grading and rolling ground to required gradient fall, slopes and camber with approved roller. Labour for trimming , levelling, grading and rolling, sub-grade to required gradient , cambers, curves and cross fall to an even surface with an approved roller to 95% heavy compaction to B.S. 1377. 250 mm Thick sub-base of 50mm crushed aggregate base course spread, levelled and rolled to required gradient, falls, and chambers with approved roller. 150 mm Thick road base of 38 mm crushed aggregate base course ditto.

G H

Prepare and apply one layer of bitumen prime coat. M 60 mm Thick premix binder course as specified spread, levelled and rolled Prepare and apply one layer of bituminous tack coat as described applied at a rate to be approved by the S.O.

Item

Description Unit Quantity BILL NO.2 ROADS, CARPARKS AND KERBS(PROVISIONAL)

Rate

Amount (RM)

A 40 mm Thick premix wearing course as specified spread, levelled and rolled to required gradients, falls and cambers with approved roller. PRECAST CONCRETE KERB

Supply and lay precast concrete kerb laid on and including outlet opening for discharge pipe where necessary, all necessary moulding, excavation reinfrocement, formwork etc and painting kerb with approved road paint all as per drawing no B Precast concrete kerb overall size 600 mm x 150mm x 305 mm high with chamfered top on one side, rounded and displayed REINFORCED COCRETE KERB C 150 mm wide x 150 mm high once chamfered reinforced concrete kerb reinforced with and including 3 nos. 10 mm diameter high tensile steel rod reinforcement an 12 mm diameter high tensile steel rod reinforcement at 300 mm centres including all necessary formwork and painting with approved paint system all as per drawing no. ROAD SIGN D Supply, delivery and installation of 3 mm thick fibre reinforced plastic road signs with reflective lettering colour and size as per JKR standard including 38 mm diameter G.I. post, excavation, base, formwork and painting all as per drawing no. 'BERHENTI' sign 'NO ENTRY ' sign

E F

NO NO

Item

Description Unit Quantity BILL NO.2 ROADS, CARPARKS AND KERBS(PROVISIONAL) ROAD MARKING

Rate

Amount (RM)

Allow for the roads and carparks demarcating lines and directional arrows in two coats of thermoplastic road paint in approved colour on finished road surfaces all as per site layout plan and detail drawing no. ITEM TESTING

Carry out CBR testing to road sub-base at locations as shown on the drawings or as directed by S.O. all as per Addendum Specification

NO

Item Description Unit Quantity BILL NO.3 - SURFACE WATER DRAINAGE (PROVISIONAL) DRAIN 300 mm Wide (internally) concrete take-off drain constructed of 300 mm half round precast concrete drain channel laid to fall on 125 mm thick reinforced concrete Grade 35 base on Grade 15 lean concrete blinding and 100 mm thick reinforced concrete Grade 35 walls, both base and wall reinforced with and including one layer of BMC A7 steel mesh reinforcement, rendering all exposed surfaces with cement and sand (1:3) mortar and including all necessary excavation, cart away, formwork, planking, strutting, bends, ends, ends, outlets, and intersection all as per drwing no.

Rate

Amount (RM)

A B C

Average 600 mm deep to invert level. Average 700 mm deep to invert level. Average 1300 mm deep to invert level.

M M M

Item Description Unit Quantity BILL NO.3 - SURFACE WATER DRAINAGE (PROVISIONAL) SUMP 750 mm X 750 mm (internally) concrete sump constructed of 150 m thick reinforced concrete Grade 35 base and walls on 50 mm thick Grade 15 lean concrete blinding both base and walls reinforced with and including 12 mm diameter and 16 mm diameter high tensile steel rod reinforcement at 150 mm centres bothways complete with 750 mm x 750 mm hot dip galvanised mild steel grille cover constructed of 60 mm x 60 mm x 6 mm thick hot dip galvanised angle frame and 50 mm x 6 mm thick hot dip galvanised flat bars welded at both ends to angle frame at 30 mm centres, rendering all exposed surfaces with cement and sand (1:3) mortar and including all necessary excavation, cart away, formwork and jointing surfaces water darin to sump, all as per drawing no.

Rate

Amount (RM)

Average mm deep to invert level.

NO

Item Description Unit Quantity BILL NO.3 - SURFACE WATER DRAINAGE (PROVISIONAL) BOX CULVERT 450 mm wide (internally) concrete box culvert constructed of 300 mm half round precast concrete drain channel laid to fall on mass concrete on 150 mm thick reinforced concrete Grade 35 base on 50 mm thick Grade 15 lean concrete blinding, 150 mm thick reinforced Grade 35 walls and and 150 mm reinforced concrete concrete Grade 35 slab, all reinforced with and including 10 mm diameter and 12 mm diameter high tensile steel rod reinforcement at 150 m and 125 mm centres bothway respectively, forming 50 mm diameter PVC weepholes with stone No.3 wrapped with geotextile at 1000mm centres on bothsides of walls, complete with formin gopening through slab to receive manhole cover (measured separately), rendering all exposed surfaces with cement and sand (1:3) mortar and inluding all necessary excavation, cart away, formwork, construction, joint, planking, strutting shoring, dewatering, etc,and jointing to drain, all as per drawing no.

Rate

Amount (RM)

Average mm deep to invert level

Item Description Unit Quantity BILL NO.3 - SURFACE WATER DRAINAGE (PROVISIONAL) REINFORCED CONCRETE KERB A 150 mm Wide x 200 mm high once chamfered reinforced concrete kerb for culvert, reinforced with and including 10 mm diameter mild steel rod at 150 m centres and 12 mm diameter high tensile steel rod reinforcement inluding all necessary formwork and painting with approved paint system all as per drawing no. GALVANISED IRON GRATING B 300 mm Wide galvanised iron grating constructed of 60 mm x 60 mm x 9 mm thick flat bar welded at both end to angle frame at 30 mm centres all as per drawing no. M

Rate

Amount (RM)

CULVERT COVER C 400 mm Diameter cast iron heavy duty circular manhole cover all as per drawing no. NO

TESTING D Test the whole of Drainage System in the presence of the S.O. with water or by other means, make good any defects, re-test on completion and leave the whole works in prefect working order to entire satisfaction of the S.O. and local Authorities.

ITEM

mount (RM)

mount (RM)

mount (RM)

mount (RM)

mount (RM)

mount (RM)

mount (RM)