You are on page 1of 6

Wall fans

High air performance and low energy consumption

Wall fans efficient and durable


The Big Dutchman wall fans are very versatile with a high performance, low energy consumption and low maintenance costs. They are also corrosion-proof and made for a long service life. Thanks to the large variety they can be ideally adapted to any type of barn. In addition to steelframe axial fans, we also offer V-belt driven fans. Let our experts advise you which solution best fits your requirements.

Axial fans with frame


Excellent adjustability
Our axial fans with frame are ideally suited for incorporation into walls. The frame has an aerodynamic shape and is made of high-quality sheet steel. The blades are made of moulded aluminium diecasting and therefore have an exceptionally high degree of efciency. Our product range includes standard fans (FC) as well as sickle-shaped fans (FE), the latter being more pressure-resistant and quieter.

Standard fan (FC)

Sickle-shaped fan (FE)

Advantages
4 excellent adjustability; 4 high air capacity at a low energy consumption; 4 low noise level; 4 quick and easy assembly; 4 high corrosion resistance; 4 long service life.

Wire mesh guard A wire mesh guard is required if the fan is installed in an accessible location.

Shutters This shutter is a self-actuated closing flap made of PVC. If the fan is at a standstill, the shutter is closed.

Dimensions and installation details


Impeller A B C D E F (in cm) (in mm) 35 435 485 375 86 75 89 40 490 540 420 91 88 102 45 535 575 480 75 96 123 50 615 655 528 77 104 141 56 675 725 589 60 119 138 63 750 805 664 64 130 154 71 810 850 763 44 150 202 80 910 970 869 34 193 252 91 1010 1070 977 48 190 197

AirMaster
Advantages

High air performance

4 optimised aerodynamics at the air admission and air exit sides for a high air flow rate; 4 specially-formed blades ensure optimum operation thus reducing energy costs; 4 the shutters open by the air flow pressure and stay open thanks to

balancing weights > minimal air resistance; 4 low noise level; 4 stable, robust and simple design; 4 easy to assemble and easy to install in the building.

Important components
Casing The fan casing consists of galvanized sheet steel, the inside construction is made of high-quality polypropylene for a high corrosion resistance. Blade and blade hub The vane has 3 or 5 specially shaped blades made of glass-fibre reinforced plastic. Air guide-rails on every blade ensure a large air capacity combined with a low resistance and thus low energy consumption. The blade hub is made of aluminium. The 5-blade AirMaster is often installed in barns with a high back pressure (cage houses with tunnel ventilation, use of exhaust air treatment systems). Shutters The shutters are opened by the air flow and then kept open by means of a balancing weight. When the fan stops, the shutters close. V-belt gearing The V-belt pulley is made of aluminium and is manufactured as one piece together with the blade hub by diecasting. The V-belt is pretensioned, further tensioning is therefore not necessary. Electric motors We use high-quality motors with a large voltage range (motor protection IP 55, approved for UL/CSA). The motor is completely closed; a separate cooling fan is not necessary. This means there is no danger of dust entering the motor or overheating of the motor.

electric motor without cooling fan with protective cover > well-protected against dust

specially-formed blades made of glass-fibre reinforced plastic with air guide-rails for optimum air performance

all 4 corners are equipped with plastic covers > no dirt corners > good hygiene

shutters are opened by the air flow > a centrifugal system is not necessary central V-belt pulley made of aluminium with pretensioned V-belt > retensioning not necessary

diagonal braces for better stability

fan with 3 or 5 blades extremely stable connection between hub and blade > copes well with high loads

Dimensions: V130 VC130


522 275 95 152 85
85

1380
133 275

1275 782

1600 1380

If used in the EU, the fans must carry the CE mark of conformity. As opposed to fans without CE mark these fans possess a protective grating (in front of the shutters at an installation height below 2.70 m).

1380

AirMaster with cone


Cone fans (VC130) are mainly used in barns with especially large air-flow performance requirements. They are also characterized by a low power consumption.

Light trap
Big Dutchman offers two light traps. The previous model reduces the amount of light passing through the fan to a minimum and is thus especially suited for rearing and breeding houses. The air performance is reduced by approx. 12 %. The new light trap PerforMacs is ideally suited for broiler and laying houses. It has been optimised aerodynamically, reducing the air performance by only approx. 10 %. The segments of both light traps are made of plastic which makes them extremely durable and easy to clean.

Technical specifications of the series AirMaster V130 / VC130


Type Code No. Speed control V130-3 1.0 PS E13 60-25-4509 V130-3 1.5 PS E13 60-25-4501 V130-3 1.5 PS E13 60-25-4503 V130-5 1.5 PS E13 60-25-4505 V130-5 1.5 PS E13 60-25-4507 V130-3 1.5 PS-R 60-25-4141 V130-5 1.5 PS-R 60-25-4140 VC130-3 1.0 PS E13 60-25-4565 VC130-3 1.5 PS E13 60-25-4561 VC130-5 1.5 PS E13 60-25-4563 VC130-3 1.5 PS-R 60-25-4020 VC130-5 1.5 PS-R 60-25-4060 NC NC FC NC FC FC FC NC NC NC FC FC 0 Pa Air capacity in m3/h 20 Pa 30 Pa 40 Pa 60 Pa 80 Pa Consumption Ampere Spec. output Watt/1000m3/h 27.5 33.6 33.6 34.3 34.3 36.7 36.8 24.6 29.9 29.8 34.3 33.4 Noise level dB(A)* 72 74 74 74 74 74 74 72 74 74 74 74 40400 36100 33100 29 900 2.2 44700 40500 38400 36 000 29 300 3.0 44 700 40500 38 400 36 000 29 300 3.0 39600 36500 35000 33 400 29 800 25 600 3.0 39600 36500 35 000 33 400 29 800 25 600 3.0 43700 39700 37500 34 800 28 600 19 200 3.1 38700 35600 34 100 32 500 28 800 24 500 3.0 44500 40400 37 800 35 400 2.3 49000 45200 43 100 40 700 35 900 3.0 43100 40000 38700 37 000 33 900 28 300 3.0 47700 43800 41 600 39 200 34 300 21 800 3.2 41800 38800 37 200 35 600 32 300 27 100 3.1

V = fan without cone; VC = fan with cone; 130 = diameter of impeller; 3 = 3-blade; 5 = 5-blade; R = standard motor (only for use outside of the EU) E13 = complies with the directive 2009/125/EC (ErP Directive) starting 2013 NC = non-controllable FC = frequency-controllable Connection values: 400 V, 50 Hz; on request available with other voltages and frequencies Weight: AirMaster without cone: 80 kg; AirMaster with cone: 99kg * Noise level measured at the outlet side 45 lateral, at a distance of approx. 2 m; all types also available unassembled

1380

Technical specifications of axial fans with frame


Description details
FC035-4EQ FE091-6DQ FC = standard fan FE = sickle-shaped fan 4 = 4-pole; 6 = 6-pole 35 = dia impeller (cm) E = 1-phase (1~ 230 V) D = 3-phase (3~ 400 V) Q = wall installation

Technical specifications: 1 ~ 230 V, 50 Hz


FC035-4EQ FC040-4EQ FC045-4EQ FC050-4EQ FC056-6EQ FC063-6EQ FC071-6EQ FC080-6EQ FE091-6EQ Code No. 60-47-9135 60-47-9140 60-47-9145 60-47-9150 60-47-9156 60-47-9163 60-47-9171 60-47-9180 60-47-9191 Power consumption (Watt) 157 243 341 450 388 545 785 1.160 895 Nominal current (Ampere) 0.75 1.3 1.9 2.3 1.95 2.7 4.1 6.3 4.6 Motor protection switch (Ampere) 1.0 1.4 2.3 2.7 2.2 3.0 4.6 6.7 5.2 Noise level (dB(A)) 46 51 53 54 48 53 55 55 57
The noise level was measured free-blowing at a 45 angle from the centre of the fan at a distance of 7 m (at 0 Pa pressure increase).

Technical specifications: 3 ~ 400 V, 50 Hz


FC045-4DQ FC050-4DQ FC056-6DQ FC063-6DQ FC071-6DQ FC080-6DQ FE091-6DQ Code No. 60-47-9645 60-47-9650 60-47-9656 60-47-9663 60-47-9671 60-47-9680 60-47-9691 Power consumption (Watt) 295 432 323 484 780 1120 939 Nominal current (Ampere) 0.8 1.1 0.74 1.4 1.8 2.7 1.95 Motor protection switch (Ampere) 0.9 1.3 0.8 1.5 1.9 3.1 2.4 Noise level (dB(A)) 53 54 48 53 55 55 57
The noise level was measured free-blowing at a 45 angle from the centre of the fan at a distance of 7 m (at 0 Pa pressure increase).

Air capacity
Single-phase power supply 230 V, 50 Hz: capacity (m3/h) / spec. output (W/1000 m3/h)
Type / Negative pressure FC035-4EQ FC040-4EQ FC045-4EQ FC050-4EQ FC056-6EQ FC063-6EQ FC071-6EQ FC080-6EQ FE091-6EQ 0 Pa 10 Pa 3 320 / 47.9 4 510 / 52.1 6 260 / 55.9 7 800 / 58.1 8 560 / 46.0 11 750 / 45.3 15 950 / 50.4 22 300 / 53.4 22 200 / 41.3 20 Pa 3180 / 50.9 4240 / 56.6 6120 / 58.0 7660 / 61.0 8210 / 49.0 11400 / 47.6 15550 / 52.7 21700 / 56.0 21200 / 44.1 30 Pa 3050 / 53.8 3950 / 61.5 5950 / 61.2 7400 / 64.6 7860 / 51.7 11000 / 50.0 15000 / 55.6 21050 / 58.7 20100 / 46.9 40 Pa 2910 / 57.0 3640 / 67.3 5780 / 64.9 7250 / 67.7 7430 / 55.3 10550 / 53.0 14600 / 58.2 20450 / 61.4 18600 / 50.8 50 Pa 2810 / 59.4 3260 / 75.2 5560 / 68.3 6900 / 73.0 6910 / 60.3 10000 / 56.8 14000 / 61.2 19850 / 64.3 17600 / 54.0 3 460 / 45.4 4 790 / 48.2 6 350 / 53.7 8 000 / 55.4 8 870 / 43.7 12 300 / 42.3 16 450 / 47.6 23 000 / 50.4 23 130 / 38.7

The capacity was measured without wire mesh guard and at an air density of 1.2 kg/m3.

Three-phase power supply 400 V, 50 Hz: capacity (m3/h) / spec. output (W/1000 m3/h)
Type / Negative pressure FC045-4DQ FC050-4DQ FC056-6DQ FC063-6DQ FC071-6DQ FC080-6DQ FE091-6DQ 0 Pa 10 Pa 6 290 / 48.0 8 120 / 53.8 8 530 / 38.7 12 380 / 40.4 16 600 / 48.2 22 440 / 51.3 22 400 / 34.4 20 Pa 6130 / 50.4 7970 / 56.3 8200 / 41.3 12000 / 43.0 16150 / 50.5 21920 / 53.6 21410 / 41.4 30 Pa 5950 / 52.9 7800 / 59.6 7850 / 44.5 11650 / 45.5 15600 / 53.1 21400 / 56.4 20450 / 44.0 40 Pa 5820 / 55.3 7630 / 62.1 7480 / 47.3 11190 / 48.7 15300 / 54.8 20900 / 58.9 19450 / 46.7 50 Pa 5650 / 58.1 7470 / 64.3 7060 / 50.7 10760 / 51.3 14800 / 57.6 20340 / 61.5 18410 / 49.7 6 470 / 45.6 8 330 / 51.1 8 850 / 36.5 12 750 / 38.0 17 000 / 45.9 22 900 / 48.9 23 370 / 36.5

The capacity was measured without wire mesh guard and at an air density of 1.2 kg/m3.

The motors are fabricated according to the IP 54 (dust-proof and water-proof) protection system. All mentioned fans 1 ~ 230 V and 3 ~ 400 V can be controlled electronically or by a transformer. On request the fans are also available frequency-controlled and/or with different supply voltage and/or 60 Hz.

Areas of application
Our wall fans are very versatile. Depen ding on the climate zone, different ventilation concepts are possible. Side and cross ventilation are often established by means of axial fans. They pull the air across the barn. Longitudinal ventilation is normally accomplished by means of AirMaster fans as these have a higher air capacity. In case of tunnel ventilation they pull the air through the barn in longitudinal direction at a high air speed. This is a so-called displacement ventilation at minimum energy consumption. CombiTunnel ventilation is best installed in climate zones with large temperature fluctuations summer/winter or day/night temperatures. In the case of decentralized exhaust air extraction via chimneys in the roof, AirMaster fans in the gable can be switched on for additional ventilation on hot summer days.

Cross ventilation

Side ventilation

Longitudinal ventilation

Tunnel ventilation

CombiTunnel ventilation

Decentralized exhaust air extraction with additional gable ventilation Technical details subject to change.en6/2013

Germany: Big Dutchman International GmbH Big Dutchman Pig Equipment GmbH Postfach 1163 49360 Vechta Tel. +49(0) 4447 801-0 Fax -237 big@bigdutchman.de www.bigdutchman.de

USA: Big Dutchman, Inc. Tel. +1 616 392 5981 bigd@bigdutchmanusa.com www.bigdutchmanusa.com Brazil: Big Dutchman (Brasil) Ltda. Tel. +55 16 2108 5300 bigdutchmanbrasil@ bigdutchman.com.br www.bigdutchman.com.br Russia: OOO Big Dutchman Tel. +7 495 2295 171 ikotov@bigdutchman.ru www.bigdutchman.ru Asia/Pacific: BD Agriculture (Malaysia) Sdn. Bhd. Tel. +60 3 33 61 5555 bdasia@bigdutchman.com www.bigdutchman.com BD Agriculture (Thailand) Ltd. Tel. +66 2 349 6531 bdt@bigdutchman.com www.bigdutchman.co.th Abb. 762 China: Big Dutchman (Tianjin) Livestock Equipment Co., Ltd. Tel. +86 10 6476 1888 bdcnsales@ bigdutchman.com www.bigdutchman.cn

You might also like