You are on page 1of 2

HP33DN Element

HP33DN Series
Interchanges for Hycon/Hydac 0330D/0500D/0660D pressure series

Hy-Pro G6 Dualglass
High Performance Filter Elements
Performance
Temperature: Element collapse -45f to 225f, -43c to 107c (buna) -20f to 250f, -29c to 120c (viton) 450 psid (31 bar)

Interchange Media
G6 media pleat pack features our latest generation of graded density glass media that delivers required cleanliness while optimizing dirt capacity. Hydac/Hycon 0330D003BN3HC 0330D003BNHC 0330D005BN3HC 0330D005BNHC 0330D010BN3HC 0330D010BNHC 0330D020BN3HC 0330D020BNHC 0500D003BN3HC 0500D003BNHC 0500D005BN3HC 0500D005BNHC 0500D010BN3HC 0500D010BNHC 0500D020BN3HC 0500D020BNHC 0660D003BN3HC 0660D003BNHC 0660D005BN3HC 0660D005BNHC 0660D010BN3HC 0660D010BNHC 0660D020BN3HC 0660D020BNHC Hy-Pro HP33DNL7-3MB HP33DNL7-3MB HP33DNL7-6MB HP33DNL7-6MB HP33DNL7-12MB HP33DNL7-12MB HP33DNL7-25MB HP33DNL7-25MB HP33DNL10-3MB HP33DNL10-3MB HP33DNL10-6MB HP33DNL10-6MB HP33DNL10-12MB HP33DNL10-12MB HP33DNL10-25MB HP33DNL10-25MB HP33DNL14-3MB HP33DNL14-3MB HP33DNL14-6MB HP33DNL14-6MB HP33DNL14-12MB HP33DNL14-12MB HP33DNL14-25MB HP33DNL14-25MB

Dynamic Filter Efficiency


DFE rated elements perform true to rating even under demanding variable flow and vibration conditions. Todays industrial and mobile hydraulic circuits require elements that deliver specified cleanliness under all circumstances . Wire mesh supports the media to ensure against cyclical flow fatigue, temperature, and chemical resistance failures possible in filters with synthetic support mesh.

Tested to ISO quality standards


ISO 2941 ISO 2942 ISO 2943 ISO 3724 ISO 3968 ISO 16889 Collapse and burst resistance Fabrication and Integrity test Material compatibility with fluids Flow fatigue characteristics Pressure drop vs. flow rate Mutipass performance testing

Fluid Compatibility
Petroleum based fluids, water glycols, polyol esters, phosphate esters, HWBF

*If No HC in Hydac/Hycon p/n or number not listed above call or consult interchange guide *For Viton seals (where A in MP p/n is V) replace the B in Hy-Pro p/n with a V. *Water removal and Dynafuzz media also available. Call or consult the Hy-Pro on line interchange guide at www.filterelement.com www.filterelement.com

For technical service call 317.849.3535 or fax 317.849.9201

L7 Dualglass Dp vs flow rate flow rate lpm


0 30 25 1 3 6 12 25 0.5 0.0 0 12 24 36 48 60 72 84 96 1.5 45 91 136 182 227 273 318 363 2.0 30 0

L14 Dualglass Dp vs flow rate flow rate lpm


78 155 233 310 388 465 543 620 1 25 3 6 12 25 1 0.5 0 0 20 40 60 80 100 120 140 160 20 15 10 5 0 2 1.5

Dp bar

15 10 5 0

1.0

flow rate gpm

flow rate gpm

L19 Dualglass Dp vs flow rate flow rate lpm


0 20 1 15 3 6 12 76 151 227 303 379 454 530 606 1.2 0.9

L26 Dualglass Dp vs flow rate flow rate lpm


0 16 1 95 189 284 379 473 568 662 757 3 0.9 12 25 0 0 25 50 75 100 125 150 175 200 0.6 0.3

10 5

0.6 0.3

8 4 0

25 0 0 20 40 60 80 100 120 140 160 0

flow rate gpm

flow rate gpm

Pressure Drop Calculation


Pressure drop curves based on oil viscosity of 141 SSU, and specific gravity = 0.86. Dp across element is proportionally related to viscosity and specific gravity. For new DP use the following conversion formula: DP element = DP curve x Actual Viscosity/141 x Actual SG/0.86
table 1 table 2 table 3 table 4 table 5

HP33DNL __ - __ __ __ __
table 1 code length 7 single 10 10 inch 14 double 19 triple 26 extended table 2 code filtration rating 1 B2.5[c] = 1000 (B1 = 200) 3 B5[c] = 1000 (B3 = 200) 6 B7[c] = 1000 (B6 = 200) 12 B10[c] = 1000 (B10 = 200) 25 B22[c] = 1000 (B25 = 200) or 25u nominal wire mesh 74 74u nominal wire mesh 149 149u nominal wire mesh table 3 code A M SF W Media G6 Dualglass w/water removal G6 Dualglass Dynafuzz wire mesh table 4 code Element OD omit Standard S reduced capacity table 5 code B V E

seal Nitrile(buna) Fluorocarbon EPR

TB33DN-0302

Hy-Pro filters are tested to the latest industry standard ISO16889 (replacing ISO4572) resulting in A new scale for defining particle sizes and determining a beta ratio.

New (ISO16889) vs Old (ISO4572) size comparison Bx(c)=1000 (ISO16889) Bx=200 (ISO4572) 2.5 5 <1 3 7 12 22 6 12 25

Dp bar

Dp psi

12

Dp psi

Dp bar

Dp bar

Dp psi

Dp psi

20

You might also like