Pressure sensors OEM are top of the range pressure sensors. With their technical qualities and the attractive price level, they are suitable for OEM applications with mean and high quantities. The compact sensor design with G B pressure connection installation. The materials and technology used make these pressure sensors insensitive to chemically aggressive media and mechanical load. Measuring ranges from 0...1 bar up to 0...1000 bar, graded in accordance with EN, offer a wide range of possible applications. The overload limit up to 10 bar is 3.5 x , between 16 and 600 bar twice and for 1000 bar 1.5 x of the rated pressure. For connection of an electrical output signal, plugs according to DIN EN 175301-803 form A or cable outlets are available. The OEM pressure sensors meet the electromagnetic compatibility (EMC) requirements of EN 61326. enables space-saving and low-weight
Features
! ! ! ! ! ! ! ! Corrosion resistant stainless steel design Medium wetted parts of stainless steel No internal sealing elements Pressure connection G1/4 B High peak pressure resistance High alternating load resistance High long-term stability For dynamic and static measurements
Ranges
Gauge pressure 0...1 bar to 0...1000 bar
Applications
Pressure measurement for OEM applications like: ! ! ! ! ! Automation, Machine and apparatus design, Air compression, Refrigeration and air conditioning, Lifting and conveyor systems.
tecsis GmbH Carl-Legien Str. 40 D-63073 Offenbach / Main Tel.: +49(0) 69 / 5806-0
DE 707 e Vertrieb Inland Fax: +49(0) 69 / 5806-170 Export Sales Fax: +49(0) 69 / 5806-177 e-Mail: info@tecsis.de Internet: www.tecsis.de p. 1 / 4
Technical data
Model Pressure type Output signal 3296 absolute pressure 3396 positive gauge pressure 2-wire system 3-wire system 3-wire system 3-wire system 0 ... 16 bar to 0 ... 1000 bar thin film other ranges on request Option
Accuracy Ranges according to EN Sensor element Repeatability Stability (annual) Case Pressure connection Wetted parts Overload limit Electrical connection Power supply Power consumption Load
4...20 mA 1...5 VDC 1...6 VDC 0...10 VDC 1 % of F.S. 1) 0 ... 1 bar to 0 ... 16bar piezoresistive " 0.1 % of F.S. " 0.3 % of F.S.in rated conditions stainless steel 1.4301 G B acccording EN 837
Temp. compens. range Temperature influence - zero point - measuring range Response time Protection type Emission Interference Electrical protection types Temperature ranges - Storage - Medium - Ambient Weight 2) 2)
Stainless steel " 10 bar 3.5 x; " 600 bar 2 x; 1000 bar 1.5 x; vacuum resistant plug acc. to DIN EN 175301-803 form A with junction box 10....30 VDC, (14...30 VDC for voltage output) output 4...20 mA: signal current output 0...20 mA: signal current + 4 mA voltage output: 8 mA 420 mA " (UB #V$ - 10V) / 0.020A 0...10 V % 10 K& 1...5 V % 5 K& 1...6 V % 6 K& 0....80C 0.4 % / 10 K 0,3 % / 10 K " 5 ms (within 10 % to 90 % of F.S) IP 65 EN 60529 / IEC 529 according to EN 61326 according to EN 61326 polarity, overvoltage and short-circuit protection -30 .... 100 C -40 .... 100 C -30 .... 80 C approx. 0.15 kg
cable outlet
of F.S.= of full scale value 1) Terminal point adjustment 2) Declaration of conformity on request
DE 707 e p2/4
Dimensions
Case plug according to DIN EN 17-5301-803 form A
48
cable outlet
75
35
42
35
42
SW19
SW19 13 2
13 2 2
5 9.5 G1/4
5 9.5 G1/4
0.1 A
G1/4
16,5 +1
13 -0,5
Min.9,5
5,5
DE 707 e p. 3 / 4
Electrical connection
Two-wire system plug according to DIN EN 175301-803 form A
UB / S+
cable outlet
brown UB / S+ 1
1 3 2
green 0V / S-
0V / SE-020
E-003
cable outlet
brown UB 1
S+
3 2
white S+
0V / S-
green 0V / S- 2
E-004
E-022
Order details
1. Model 2. Measuring range 3. Output signal 4. Options
DE 707 e p. 4 / 4