Professional Documents
Culture Documents
TK
owners guide
ThyssenKrupp Elevator manufactures four basic types of elevators: OILDRAULIC , TRACTION, FREIGHT and our MACHINE ROOM-LESS elevators. The information in this Owners Guide applies to all four types.
SAFETY GUIDELINES FOR P R O P E R U S E O F A N E L E VAT O R .
Following a few simple tips can help your passengers enjoy a safe, trouble-free ride. H Enter and exit the elevator promptly. Do not hold the doors open and carry on a conversation. This will delay proper elevator service. H Watch your step when entering or exiting the elevator. If uneven stops occur, call your ThyssenKrupp Elevator TEAMService specialist. H Do not reach into the door opening to disrupt the Microlight infrared beams. This device is provided to reopen the doors if an obstruction occurs. H Instruct tenants to promptly report any elevator malfunctions to the building manager. H Children should never ride unattended. They should not be allowed to play in an elevator.
SECURITY GUIDELINES.
Full-time maintenance or security personnel should be acquainted with the special features of the elevator so that they can react properly in any situation.
Keys to the elevator should only be used by authorized personnel and kept in a secure central location.
Lock the machine room door at all times. Only authorized personnel should be allowed to enter, and no materials may be stored there other than those for elevator maintenance. Refer to Safety Code for Elevators and Escalators ASME A17/B44, Canadian Standards Association CSA/CAN-B4494 for details.
When you contact your local ThyssenKrupp Elevator TEAMService specialist for a trouble call please have the following information available.
Proper building name and address Which elevator is the troubled unit An accurate, detailed description of the problem
3
safety features
EVERY THYSSENKRUPP ELEVATOR PRODUCT IS EQUIPPED WITH A NUMBER OF DEVICES FOR THE PROTECTION AND CONVENIENCE OF PASSENGERS. To ensure safety, personnel should become familiar with the function of the keyswitch and push-button operations on the elevators. ALL KEY OPERATION SHOULD BE USED BY AUTHORIZED PERSONNEL ONLY. Consult your local ThyssenKrupp Elevator representative for state or local codes that vary from the national code. Not all the features listed below will be installed on your elevator.
H MICROLIGHT Electronic door edges detect when the elevator doorways are blocked, keeping them open until the blockage is removed. If a beam is interrupted, the doors will not close or will automatically reopen if already closing. This door protection system replaces the safety edge and photo eye. H VENT SLOTS All elevators are equipped with vent slots to ensure adequate air flow. H EMERGENCY EXITS All elevators have an emergency exit on either the top of the car, the side of the car, or both. These exits should be locked at all times and used only by emergency personnel. H H O I S T W AY D O O R K E Y W AY (WHERE ALLOWED BY CODE) Allows access to the hoistway if the elevator is not at the landing. The hoistway should be accessed only by elevator or emergency
be safe
personnel.
car keyswitches
CARD READER
ON OFF
ON INSPECTION OFF
INSPECTION KEYSWITCH
Used for inspection mode.
HOISTWAY ENABLE
ON OFF
ON LIGHT OFF
LIGHT KEYSWITCH
Controls lighting in elevator.
H O I S T W AY E N A B L E KEYSWITCH
Used for inspection mode.
ON OFF
ON OFF
ATTENDANT SERVICE
ON OFF
AT T E N D A N T SERVICE KEYSWITCH
Activates and deactivates attendant service feature in car.
STOP RUN
RUN/STOP KEYSWITCH
For emergency stop in the hoistway. No alarm bell is activated.
Mounted in the hall station to call the car to the respective floor in an emergency situation.
H O I S T W AY A C C E S S KEYSWITCH
Gives access for inspectors from hall.
L O B B Y PA R K KEYSWITCH
Brings car to designated floor and shuts down car operation.
LOCKOUT KEYSWITCH
Enables authorized personnel to lockout access to a specific floor.
HALL LANTERN
Up and down arrows will illuminate, indicating which direction the elevator will travel when leaving the floor. A tone sounds once if the elevator is traveling up, twice if going down.
H A L L P O S I T I O N I N D I C AT O R ALARM BUTTON
Sounds a bell to alert others that someone in the elevator needs assistance. Numbers or letters illuminate, indicating the location of the elevator in the hoistway.
EMERGENCY LIGHT
Illuminates automatically when a power failure occurs.
emergency procedures
KNOW AND UNDERSTAND HOW YOUR INVESTMENT WITH THYSSENKRUPP ELEVATOR CAN SERVE AND PROTECT YOU AND YOUR TENANTS IN THE EVENT OF AN EMERGENCY. POWER FAILURE. S TA L L E D E L E VAT O R . In the event of the loss of normal power, limited elevator service is continued through an automatic transfer to our Emergency Power operation. Then, when normal power is restored, the elevators will automatically transfer back to normal operation. If there is not a standby power supply, the elevators will stop in progress and remain at rest until normal power is restored. H EMERGENCY POWER OPERATION Establish and maintain communication with the passengers inside the elevator by using the elevator's telephone or intercom, or simply by calling through the An Emergency Power lowering system provides automatic or manual return of an elevator to a predetermined landing during a blackout or single-phase electrical condition. ThyssenKrupp Elevator offers options for emergency power operation. If there is a standby power supply, the elevators will automatically return to the lowest landing and the doors will open, allowing the passengers to exit. The doors will then close and the elevator will shut down. The elevators will remain at that landing until a car is manually selected. H Some applications allow the elevators to lower to a pre-selected landing, cycle the doors, then shut down. If the designated landing is above the elevator at the time normal power is lost, the car will proceed to the next lowest landing, cycle the doors and shut down. Personnel should be notified of which landing the elevators will return to in the event of power failure. H Find out whether the regular elevator lighting or the emergency light is operating. This will help determine the degree of power failure. BATTERY LOWERING H Ask the passengers not to smoke. H Ask the passengers to stand clear of the doors. Find out how many people are in the elevator. H Contact your local ThyssenKrupp Elevator office and inform them of the situation. H Find out if anyone is injured or ill. If so, arrange for medical assistance. doors. Reassure the passengers that steps are being taken to remove them from the elevator. In the unlikely event that an elevator becomes stalled with passengers aboard, do not attempt a rescue yourself. While all ThyssenKrupp elevators have an emergency exit, this exit should be locked at all times and used only during an emergency by trained personnel. Please follow these instructions carefully:
As an option on our hydraulic elevators, we offer a Battery Lowering Unit, which provides supplemental power for the elevator when the building loses power. The unit returns the elevator to the designated landing and opens the doors, allowing passengers to exit safely.
be safe
FIRE SERVICE. In the event of a fire, never use the elevators to evacuate the building; use the stairways to get to a safe place. Under no circumstances should anyone except trained firefighters be allowed to use the elevators after a fire has been reported.
Fire Service is initiated automatically by the buildings smoke detectors or by activating the Fire Service keyswitch located in the hall.
When this service is initiated, all hall and car calls are cancelled, the elevators return to a designated floor, the doors open and remain open. Trained firefighters then may activate the Fire Service keyswitch in the elevator and gain control of the car. Combination Hall Station / Fire Service Keyswitch (2004 CODE)
To return to normal operation, return the elevator to the assigned Fire Service floor, hold constant pressure on the door open push-button and turn the Fire Service keyswitch in the car station to the Off position. Next, place the hall Fire Service keyswitch in the Bypass or Reset position. Pause momentarily, then turn the keyswitch to the Off position. Only authorized personnel should be permitted to reset Fire Service, after being certain there is no fire in the building, and the smoke/heat detectors have been reset.
FIRE SERVICE JEWEL Illuminates when Fire Service operation is activated, indicating the elevator is returning to the designated landing.
our commitment
Owners guide.
THANK YOU FOR INVESTING IN A THYSSENKRUPP ELEVATOR. OUR PRODUCTS ARE BUILT IN NORTH AMERICA AND ARE SOLD AND SERVICED ALL OVER THE WORLD. HERES WHAT OUR COMMITMENT TO EXCELLENCE MEANS TO YOU: GLOBAL STRENGTH WITH A LOCAL FOCUS. ThyssenKrupp Elevator, one of the worlds largest elevator companies, provides customers throughout North America with a powerful combination of elevator products, service and technology. We are leading the industry with innovative technology and unsurpassed customer service, providing global strength with a local focus. EXPERIENCE. Our employees are the most knowledgeable in the elevator industry. With on-going training programs that include field and local training, as well as regular factory seminars, ThyssenKrupp Elevator personnel are the most well-informed elevator specialists in the industry. They are supported 24/7 by factory field engineers who, if needed, are ready to travel at a moments notice. If you have questions or need assistance, you'll be glad you chose to purchase your elevator from the industry leader.
TEAMService. When your warranty has expired, youll want to make sure your elevator receives the kind of preventative maintenance which ensures optimum safe performance. As the manufacturer, ThyssenKrupp Elevator is able to furnish fast, reliable service and expertly trained technicians to protect your valuable investment. Choose our comprehensive TEAMService Platinum Premier elevator service plan which provides service 24 hours a day. We can even design a program customized to fit your specific needs.
PA R T S . Nobody knows your elevator like the people who built and installed it. Since every ThyssenKrupp Elevator office maintains an extensive inventory of spare parts and has access to our national parts distribution system, we can provide quality replacement parts at a moments notice.
C O M P L I A N C E W I T H R E G U L AT I O N S . The Americans with Disabilities Act (ADA) and Canadian Standards Association (CSA) stipulates that buildings must comply with the new requirements that make elevators easier to operate by people with disabilities. Should it be determined that your elevator is not in compliance with current regulations, ThyssenKrupp Elevator offers quick and cost-effective solutions.
M O D E R N I Z AT I O N . ThyssenKrupp Elevators modernization products can make an old elevators performance and appearance like new again. The ThyssenKrupp Elevator modernization department is staffed with technicians and engineers experienced in every kind of elevator modernization. We can customize a modernization package that is both time and cost efficient.
10
11
version 11.08 All illustrations and specifications are based on information in effect at time of publication approval. ThyssenKrupp Elevator reserves the right to change specifications or design and to discontinue items without prior notice or obligation. Copyright 2008 ThyssenKrupp Elevator Corporation TKE0093 v11.08 5M 1108 GSI Printed in USA
ThyssenKrupp Elevator P.O. Box 2177 Memphis, TN 38101 Tel: 877-230-0303 (Toll Free)
thyssenkruppelevator.com
12