SECTION 10900 BAZAAR TENT STRUCTURE
THIS DRAWING AND THE INFORMATION CONTAINED HEREIN ARE THE SOLE PROPERTY OF SAUDI ARAMCO. NO REPRODUCTION IN FULL OR IN PART SHALL BE OBTAINED FROM THIS DOCUMENT WITHOUT THE WRITTEN CONSENT OF ITS OWNER.

ENGG

CERT

PMT

PART 1 - GENERAL 1.01 SCOPE OF WORK A. Work included in this section comprises of the design, manufacture, supply and installation of tent structure including the foundation. The manufacturer shall be responsible for executing all aspects of design, engineering and manufacture. Calculations and drawings to be submitted to Saudi Aramco for approval..

DESCRIPTION

B.

1.02
DATE JOB/EWO

RELATED SECTIONS Section 03100 Section 03200 Section 03300 Section 05120 Section 08120 Section 08520 Section 08800 Concrete Formwork. Concrete Reinforcement. Cast in place concrete. Structural steel.. Aluminum doors and frames. Aluminum windows. Glazing.

REV. NO.

DISCIPLINE ENGINEER

__ ________ _ DATE: ________

PROJECT ENGINEER
____________ DATE

CERTIFIED _ __________
DATE: ________

1.03

REFERENCES A. B. C. Submit under provision of section 01300. UFC ASTM E84 Uniform Fire Code (Article32). Surface burning characteristics of building materials.

CONSTRUCTION AGENCY
________________ DATE:

OPERATIONS
______________ DATE:_________ REVISION CERTIFICATION EDSD VERIFICATION THIS INDICATES THAT REV. NO.________ OF THIS DRAWING IS COVERED, FOR ALL APPROVAL/CERTIFICATION REQUIREMENTS,, CONTROL NUMBER BY DRAWING COMPLETION CERTIFICATE (DCC) NO.: __________________________ By:

D.
Date:

SAUDI ARAMCO Engineering Standards (SAES): M-001 Structural Design Criteria for Non-Building Structures. Preparation of Structural Calculations.

A-204 E.

SAUDI ARAMCO Engineering Practice (SAEP):


SECTION 10900

CONSTRUCTION SPECIFICATIONS
KAUST TOWN CENTER RESIDENTIAL & COMMUNITY SUPPORT BUILDINGS

DWG. TYPE PLANT NO. INDEX

DRAWING NO.

SHT. NO. REV. NO.

DOC

K55 SAUDI ARABIA

VE-417361 BI-25-00002

RABIGH

14-Sep-07

JOB/EWO#

1 OF 5

00

Saudi Aramco 2616-ENG (3/99)


OPERNS.


SAUDI ARAMCO OIL COMPANY
1023 Contractor Quality Assurance and Quality Control Requirements. Qualification of NDT Personnel. Qualification of Non-Saudi Aramco NDT Personnel.
THIS DRAWING AND THE INFORMATION CONTAINED HEREIN ARE THE SOLE PROPERTY OF SAUDI ARAMCO. NO REPRODUCTION IN FULL OR IN PART SHALL BE OBTAINED FROM THIS DOCUMENT WITHOUT THE WRITTEN CONSENT OF ITS OWNER.

CERT

PMT

ENGG

1140 1142

DESCRIPTION

F.

SAUDI ARAMCO Materials System Specifications (SAMSS): 12-SAMSS-007 Steel Structures.

G.

American Institute of Steel Construction (AISC): 1. Specification for the Design, Fabrication and Erection of Structural steel buildings. Code of Standard Practice for steel buildings and bridges. Quality Criteria and Inspection Standards. Structural Steel Detailing.

DATE JOB/EWO

2. 3. 4. H.

REV. NO.

DISCIPLINE ENGINEER

American Welding Society (AWS): A2.0 D1.1-96 Standard Welding Symbols. Structural Welding Code Steel.

__ ________ _ DATE: ________

PROJECT ENGINEER
____________ DATE

CERTIFIED _ __________
DATE: ________

I.

American Society for Testing and Materials (ASTM): A36/36M A53-B Standard Specification for Structural Steel. Standard specification for pipe, steel, black and hot dipped, zinc coated, welded and seamless. Standard specification for structural bolts, steel, heat treated 120/150 Ksi minimum tensile strength.

CONSTRUCTION AGENCY
________________ DATE:

OPERATIONS
______________ DATE:_________ REVISION CERTIFICATION EDSD VERIFICATION THIS INDICATES THAT REV. NO.________ OF THIS DRAWING IS COVERED, FOR ALL APPROVAL/CERTIFICATION REQUIREMENTS,, CONTROL NUMBER BY DRAWING COMPLETION CERTIFICATE (DCC) NO.: __________________________ By:

A325

1.04
Date:

SUBMITTALS Submit to SAUDI ARAMCO engineer copies of all materials required to establish the compliance with this section. Submittals shall include at least the following.

SECTION 10900

CONSTRUCTION SPECIFICATIONS
KAUST TOWN CENTER RESIDENTIAL & COMMUNITY SUPPORT BUILDINGS

DWG. TYPE PLANT NO. INDEX

DRAWING NO.

SHT. NO. REV. NO.

DOC

K55 SAUDI ARABIA

VE-417361 BI-25-00002

RABIGH

14-Sep-07

JOB/EWO#

2 OF 5

00

Saudi Aramco 2616-ENG (3/99)


OPERNS.


SAUDI ARAMCO OIL COMPANY
A. Detailed product and layout drawings showing all important details of construction and dimension, anchor bolts locations and all aspects of structure design. The drawings should include detailed plan, elevation, and sections. Tent Fabric samples of size 300 x 300 mm in the color and finish selected by SAUDI ARAMCO. Track record (project list) of projects completed in this area. Submit under provisions of Section 01300. Design Calculations Submit design calculations by tent structural manufacturer to SAUDI ARAMCO Representative in a neat, compact and orderly form. Reference all equations used or assumptions made to appropriate source of information by page and paragraph number and supply copy of same. Calculations shall include, but are not necessarily limited to the following: 1. Stresses in members due to bending, shear, compression and torsion caused by vertical and lateral loads and handling. Deflection. Design calculations for stresses at connections and supports under both in-place and hoisting phase. Documentation to comply with SAES-4-204
THIS DRAWING AND THE INFORMATION CONTAINED HEREIN ARE THE SOLE PROPERTY OF SAUDI ARAMCO. NO REPRODUCTION IN FULL OR IN PART SHALL BE OBTAINED FROM THIS DOCUMENT WITHOUT THE WRITTEN CONSENT OF ITS OWNER.

ENGG

CERT

PMT

B.

DESCRIPTION

C. D. E.

REV. NO.

DATE JOB/EWO

DISCIPLINE ENGINEER

__ ________ _ DATE: ________

2. 3.

PROJECT ENGINEER
____________ DATE

CERTIFIED _ __________
DATE: ________

4. F.

Materials Data 1. Submit material information and data for the SAUDI ARAMCO Representative's review at least twenty-one (21) calendar days prior to scheduled start date of any fabrication.

CONSTRUCTION AGENCY
________________ DATE:

OPERATIONS
______________ DATE:_________ REVISION CERTIFICATION EDSD VERIFICATION THIS INDICATES THAT REV. NO.________ OF THIS DRAWING IS COVERED, FOR ALL APPROVAL/CERTIFICATION REQUIREMENTS,, CONTROL NUMBER BY DRAWING COMPLETION CERTIFICATE (DCC) NO.: __________________________ By:

G.

Shop Drawings 1. Submit shop drawings to the SAUDI ARAMCO Representative for approval. Shop drawings shall be prepared under the direction of a registered professional engineer, and so certified.

Date:

2.

SECTION 10900

CONSTRUCTION SPECIFICATIONS
KAUST TOWN CENTER RESIDENTIAL & COMMUNITY SUPPORT BUILDINGS

DWG. TYPE PLANT NO. INDEX

DRAWING NO.

SHT. NO. REV. NO.

DOC

K55 SAUDI ARABIA

VE-417361 BI-25-00002

RABIGH

14-Sep-07

JOB/EWO#

3 OF 5

00

Saudi Aramco 2616-ENG (3/99)


OPERNS.


SAUDI ARAMCO OIL COMPANY
THIS DRAWING AND THE INFORMATION CONTAINED HEREIN ARE THE SOLE PROPERTY OF SAUDI ARAMCO. NO REPRODUCTION IN FULL OR IN PART SHALL BE OBTAINED FROM THIS DOCUMENT WITHOUT THE WRITTEN CONSENT OF ITS OWNER.

PMT

1.05

SYSTEM DESCRIPTION A. B. C. The Tent structure shall be 10m x 13m rectangular shape. Tent structure height = 7M (approximately). Clearance at lowest point = 3M (approximately) Tent shall have a permanently fixed label bearing the following information: 1. 2. 3. Identification of tent size and fabric or material type. Identification of flame retardant treatment as per UFC 1103. The trade name and type of flame retardant outlined in the flame retardant treatment. The name of person and firm that applied the flame retardant.

ENGG

CERT

DATE JOB/EWO

DESCRIPTION

D.

4. 1.06

REV. NO.

SUPPLIER QUALIFICATIONS A. The supplier shall be an experienced and qualified manufacturer of proven ability that has regularly engaged in the successful manufacture and installation of large size tent structures.

DISCIPLINE ENGINEER

__ ________ _ DATE: ________

PROJECT ENGINEER
____________ DATE

PART 2- PRODUCT 2.01 SUPPLIERS A. 1) CANOBBIO Supplier: Al Rafid Steel Industries. Tel: 01 477 8591 Fax: 01 265 1953 Export Vlaanderen Tel: 01 480 1760 Fax: 01 480 1764

CERTIFIED _ __________
DATE: ________

CONSTRUCTION AGENCY
________________ DATE:

2)

OPERATIONS
______________ DATE:_________ REVISION CERTIFICATION EDSD VERIFICATION THIS INDICATES THAT REV. NO.________ OF THIS DRAWING IS COVERED, FOR ALL APPROVAL/CERTIFICATION REQUIREMENTS,, CONTROL NUMBER BY DRAWING COMPLETION CERTIFICATE (DCC) NO.: __________________________ By:

B. 2.02
Date:

Substitutions: under provisions of Section 16000.

MATERIAL A. Tent Fabric Fabric shall be non combustible-flame-resistant double skin suitable for outdoor installation 100% PVDF. Color to be selected by SAUDI ARAMCOs Representative.
SECTION 10900

CONSTRUCTION SPECIFICATIONS
KAUST TOWN CENTER RESIDENTIAL & COMMUNITY SUPPORT BUILDINGS

DWG. TYPE PLANT NO. INDEX

DRAWING NO.

SHT. NO. REV. NO.

DOC

K55 SAUDI ARABIA

VE-417361 BI-25-00002

RABIGH

14-Sep-07

JOB/EWO#

4 OF 5

00

Saudi Aramco 2616-ENG (3/99)


OPERNS.


SAUDI ARAMCO OIL COMPANY
Outer skin shall be Ferrari 1202 Fluoto or approved equal. Inner skin shall be Ferrari 702 Series 8000 or approved equal. Heat transfer coefficient of a single-membrane covering is about 4.9 [kcal/m2h oC]. For a double-membrane covering, it depends on the distance between them, and goes from 2.3 to 2.7. B. Steel Structure Steel members to be: Powder coated. Representative. Color to be selected by SAUDI ARAMCOs
THIS DRAWING AND THE INFORMATION CONTAINED HEREIN ARE THE SOLE PROPERTY OF SAUDI ARAMCO. NO REPRODUCTION IN FULL OR IN PART SHALL BE OBTAINED FROM THIS DOCUMENT WITHOUT THE WRITTEN CONSENT OF ITS OWNER.

DESCRIPTION

ENGG

CERT

PMT

PART 3 - EXECUTION
DATE JOB/EWO

3.01

INSTALLATION Installation of the tent structure elements shall be in accordance to the manufacturers recommendations.

REV. NO.

3.02
DISCIPLINE ENGINEER

DELIVERY, STORAGE AND HANDLING The contractor shall ensure proper handling and storage at site in accordance with manufacturers recommendations.

__ ________ _ DATE: ________

PROJECT ENGINEER
____________ DATE

3.03

WARRANTY The manufacturer shall guarantee the completed tent structure installation to be free from defects in workmanship and or materials for a minimum period of five (5) years from the date of completion.

CERTIFIED _ __________
DATE: ________

CONSTRUCTION AGENCY
________________ DATE:

END OF SECTION

OPERATIONS
______________ DATE:_________ REVISION CERTIFICATION EDSD VERIFICATION THIS INDICATES THAT REV. NO.________ OF THIS DRAWING IS COVERED, FOR ALL APPROVAL/CERTIFICATION REQUIREMENTS,, CONTROL NUMBER BY DRAWING COMPLETION CERTIFICATE (DCC) NO.: __________________________ By:

Date:

SECTION 10900

CONSTRUCTION SPECIFICATIONS
KAUST TOWN CENTER RESIDENTIAL & COMMUNITY SUPPORT BUILDINGS

DWG. TYPE PLANT NO. INDEX

DRAWING NO.

SHT. NO. REV. NO.

DOC

K55 SAUDI ARABIA

VE-417361 BI-25-00002

RABIGH

14-Sep-07

JOB/EWO#

5 OF 5