4.09
Page 1 of 3
A C
1,480 Q
1,770 1,285
178 23 079.1
No. of Cyls.
A (mm)
* B (mm)
* C (mm)
H (mm)
5 (720 r/min) 5 (750 r/min) 6 (720 r/min) 6 (750 r/min) 7 (720 r/min) 7 (750 r/min) 8 (720 r/min) 8 (750 r/min) 9 (720 r/min) 9 (750 r/min)
4,346 4,346 4,791 4,791 5,236 5,236 5,681 5,681 6,126 6,126
2,486 2,486 2,766 2,766 2,766 2,766 2,986 2,986 2,986 2,986
6,832 6,832 7,557 7,557 8,002 8,002 8,667 8,667 9,112 9,112
3,712 3,712 3,712 3,712 3,899 3,899 3,899 3,899 3,899 3,899
42.3 42.3 45.8 46.1 52.1 52.1 56.3 58.3 63.9 63.9
178 33 898.3
P Free passage between the engines, width 600 mm and height 2,000 mm Q Min. distance between engines: 2,900 mm (without gallery) and 3,100 mm (with gallery) * Depending on alternator ** Weight includes a standard alternator All dimensions and masses are approximate and subject to change without prior notice.
MAN Diesel
198 82 841.0
MAN Diesel
4.09
Page 2 of 3
58 58 64 21.5 58
58 58 92 24.8 58
C m3/h 5) kg/kWh bar Charge air pressure Air required to dissipate heat radiation (engine) (t2-t1= 10C) m3/h Exhaust gas data 6) Volume ow (temperature turbocharger outlet) m3/h 7) Mass ow t/h Temperature at turbine outlet C Heat content (190C) kW Permissible exhaust back pressure mbar Pumps a) Engine driven pumps m3/h HT circuit cooling water (2.5 bar) m3/h LT circuit cooling water (2.5 bar) m3/h Lube oil (4.5 bar) b) External pumps 8) Diesel oil pump (5 bar at fuel oil inlet A1) m3/h Fuel oil supply pump (4 bar discharge pressure) m3/h Fuel oil circulating pump (8 bar at fuel oil inlet A1) m3/h Starting air data Air consumption per start, incl. air for jet assist (IR/TDI) Nm3
50 53 12,792 14,924 6.67 6.67 22,682 26,247 27,381 14.4 388 857 31,944 16.8 388 1,000
< 30
1) LT cooling water ow rst through LT stage charge air cooler, then through lube oil cooler, water temperature outlet engine regulated by mechanical thermostat. 2) HT cooling water ow rst through HT stage charge air cooler, then through water jacket and cylinder head, water temperature outlet engine regulated by mechanical thermostat. 3) Tolerance: + 10% for rating coolers, - 15% for heat recovery.
4) Basic values for layout of the coolers. 5) Under above mentioned reference conditions. 6) Tolerance: quantity +/- 5%, temperature +/- 20C. 7) Under below mentioned temperature at turbine outlet and pressure according above mentioned reference conditions. 8) Tolerance of the pumps delivery capacities must be considered by the manufactures.
Fig. 4.09.02a: List of capacities for L27/38, 720 rpm, IMO Tier II
MAN Diesel
198 82 841.0
MAN Diesel
4.09
Page 3 of 3
C m3/h 5) kg/kWh bar Charge air pressure Air required to dissipate heat radiation (engine) (t2-t1=10C) m3/h Exhaust gas data 6) Volume ow (temperature turbocharger outlet) m3/h 7) Mass ow t/h Temperature at turbine outlet C Heat content (190C) kW Permissible exhaust back pressure mbar Pumps a) Engine driven pumps m3/h HT circuit cooling water (2.5 bar) m3/h LT circuit cooling water (2.5 bar) m3/h Lube oil (4.5 bar) b) External pumps 8) Diesel oil pump (5 bar at fuel oil inlet A1) m3/h Fuel oil supply pump (4 bar discharge pressure) m3/h Fuel oil circulating pump (8 bar at fuel oil inlet A1) m3/h Starting air data Air consumption per start, incl. air for jet assist (IR/TDI) Nm3
Air temperature LT-water temperature inlet engine (from system) Air pressure Relative humidity Temperature basis Setpoint HT cooling water engine outlet 1) Setpoint LT cooling water engine outlet 2) Setpoint Lube oil inlet engine Number of Cylinders Engine output Speed Heat to be dissipated 3) Cooling water (C.W.) Cylinder Charge air cooler; cooling water HT Charge air cooler; cooling water LT Lube oil (L.O.) cooler Heat radiation engine Flow rates 4) Internal (inside engine) HT circuit (cylinder + charge air cooler HT stage) LT circuit (lube oil + charge air cooler LT stage) Lube oil External (from engine to system) HT water ow (at 40C inlet) LT water ow (at 38C inlet) Air data Temperature of charge air at charge air cooler outlet Air ow rate
C C bar % C C C kW rpm kW kW kW kW kW
45 38 1 50 79 nominal (Range of mechanical thermostatic element 77 to 85) 35 nominal (Range of mechanical thermostatic element 29 to 41) 66 nominal (Range of mechanical thermostatic element 63 to 72) 6 7 8 9 2,100 2,450 2,800 3,150 750 315 679 181 282 70 368 797 208 329 81 421 916 234 376 93 473 1037 258 423 104
4.09
< 30
1) LT cooling water ow rst through LT stage charge air cooler, then through lube oil cooler, water temperature outlet engine regulated by mechanical thermostat. 2) HT cooling water ow rst through HT stage charge air cooler, then through water jacket and cylinder head, water temperature outlet engine regulated by mechanical thermostat. 3) Tolerance: + 10% for rating coolers, - 15% for heat recovery.
4) Basic values for layout of the coolers. 5) Under above mentioned reference conditions. 6) Tolerance: quantity +/- 5%, temperature +/- 20C. 7) Under below mentioned temperature at turbine outlet and pressure according above mentioned reference conditions. 8) Tolerance of the pumps delivery capacities must be considered by the manufactures.
Fig. 4.09.02b: List of capacities for L27/38, 750 rpm, IMO Tier II
MAN Diesel
198 82 841.0