AIR TO WATER HEAT PUMPS

Hot water and comfortable ambient temperature all year round

HEAT PUMP PRINCIPLE

REDUCE CO2 EMISSIONS WITH ENERGY EFFICENT SOLUTIONS


Heat pumps use mainly ambient air for the production of domestic heating. This source of renewable energy reduce the overall energy consumption and minimize the amount of CO2 emissions.

CARRIER. A UNITED TECHNOLOGIES COMPANY

Whether you need air conditioning for a new building or a refurbishment project, for a commercial centre, an oce application or an industrial process, Carrier can oer you a wide range of solutions to meet your needs from liquid chillers/heat pumps, fan coil solutions, air treatment/ handling solutions right through to standard and tailormade system controls. Carrier provides heating, ventilating and air conditioning solutions for optimised individual customer comfort.

OUR MISSION IS TO MAKE THE WORLD A BETTER PLACE

T EU is committed to reducing The ts overall emissions to at least 20% t below 1990 levels by 2020, and is b re eady to scale up this reduction to as much as 30% under a new global a climate change agreement when c other developed countries make o comparable eorts. c It has also set itself the target of increasing the share of renewables in energy use to 20% and increase energy eciency by 20% before 2020.

RENEWABLE ENERGY

3 kW

+ =

ELECTRICITY

1 kW 4 kW

HEATING POWER

IMPROVE THE ENERGY USE IN YOUR HOME

In recognition of our commitment to developing products for a safer, cleaner and less polluted planet, Carrier received the prestigious Ozone Protection Award (EPA).

refrigerant
2 CARRIER HEATING SYSTEMS 3

RADIATORS
E Existing low temperature radiators can be used with heat pump heating system. u The electronic control of the module keep T the temperature constant avoiding heating peaks and heat waste. p

FAN COILS

THE IDEAL SOLUTION


XP Energy heat pump system is designed to satisfy dierent applications (new houses or renovation) and dierent conditions (one zone, two zone, sanitary hot water production).

T Terminal fan coil distribute the heat or cold air in the ambient. Its fan speed can be a re egulated to match user personal needs.

UNDER FLOOR HEATING


W Water circuit run in underoor pipes. With this system heat energy (radiant W heat and heat conduction) is diused h evenly in the indoor. Using the heat e pump in cooling mode the same circuit p o cool the indoor ambient in summer period.

HEAT PUMP

CONTROL SOLAR PANEL HYDRONIC MODULE SANITARY HOT WATER TANK


The hot water stored in the tank is kept in temperature using the heat generated by the heat pump. The electrical heating is used only whenever there is a peak request for o hot water. h Dierent tank type size are available to D adapt to any domestic need. With the a anti-legionella feature included the system a will periodically heat over 70C to prevent w bacteria formation. b T user friendly interface is placed in the The hydronic module. Provide triple function, h nstallation parameters and setpoints, n user selectable programs and scheduled u operation, system monitoring and self check o diagnosis. d

SWIMMING POOL HEATER


Heat pumps have spare capacity available in the intermediate season which can be used to heat a swimming pool without altering the comfort in the house. This heat exchanger is designed to recover this capacity.

CARRIER HEATING SYSTEMS

STOCKHOLM KRAKOW

LONDON

-3

-5 -10

-15

FRANKFURT

INVERTER DRIVEN TECHNOLOGY


The advance electronic management of the compressor operation enable consistent energy savings compared to a traditional xed speed system:

Yearly distribution of outdoor air temperature in number of hours

-15 -7 -5

PARIS

-7

-3
ATHENS

HIGH COP IN PART LOAD


gp

-3
MADRID ROME

TEMPERATURE CONTROL
INVERTER

FIXED SPEED

ENERGY SAVINGS
Size the system based on the temperature condition in your area. Youll be able to calculate upfront the savings on your energy bills and the time needed to fully recover your investment.

SOFT START

TAX REDUCTION AND INCENTIVE FLOATING SETPOINT

CARRIER HEATING SYSTEMS

SINGLE ZONE SYSTEM up to 6,5 kW

ER INTERFACE SANITARY WATER TANK

Emitters type SINGLE ZONE

FLOOR

FAN COIL

RADIATOR ADIATOR

TOTAL COMFORT SOLUTION


Enjoy the comfortable well being in every season, using less energy and with the personal satisfaction of helping to preserve our delicate environment.

ULTRA PRECISE TEMPERATURE CONTROL


Conversely to standard thermostat that cannot avoid temperature uctuation. Carrier have developed and adaptive control which calculate also the inertia of the building. Its powerful software elaborate the signals coming from the sensors and adjust the operating parameters accordingly. The result is the optimal room temperature maintained constantly in every condition.

INVERTER VERTER HEAT PUMP

HYDRONIC YDRONIC MODU MODULE

TWO ZONES SYSTEM up to 11,5 kW


USER INTERFACE

Emitters type FIRST ZONE

HEATING
Standard Thermostat

SANITARY WATER TANK

FLOOR
Low or medium temperature

FAN COIL

RADIATOR ADIATOR

Emitters type SECOND ZONE


Buer tank

INVERTER HEAT PUMP PUM


Indoor heating inertia is not considered

25lt

HYDRONIC HYDRON MODULE

FLOOR
Low temperature

FAN COIL

RADIATOR ADIATOR

COOLING

Carrier Thermostat control

UNIQUE IN THE MARKET


Temperature is continuosily controlled and regulated

HOT WATER

CARRIER HEATING SYSTEMS

THE ADVANTAGES OF THE LOW TEMPERATURE


Using low temperature emitters increases the eciency of the system. As you can see in the graph the performance of the Heat pump (COP) is not constant. It is measured at a rating point for system reference, but it increases when the temperature of the water circulating in the system is low.

1,0

2,0

3,0

4,0

35C LWT 45C LWT

55C LWT
9 kW unit at 7C Outdoor temperature

THE RIGHT SYSTEM


The XP Energy heat pump solution is a cost eective choice in the long run, even in the areas with low temperature in winter time. In these condition the heat pump operation, depending on the type of system installed can be: Mono-energetic or bi-valent. MONOENERGETIC SYSTEM

Therefore by selecting a low temperature emitter like the Carrier fan coils youll increase the eciency, reduce the energy consumption and shorten the overall pay back time.

Carrier XP Energy Two zone system gives the possibility to distribute the water at dierent temperature, based on the emitters demand and the signals coming from the temperature sensors.

BIVALENT SYSTEM

All year round the highest COP, due to the lowest LWT

10

CARRIER HEATING SYSTEMS

11

LONG PIPE RUNS AND FLEXIBLE INSTALLATION Outdoor units have long pipe runs (up to 70 m) and pipe elevation (30 m) therefore can be placed in the best suitable spot of your home, without aectign the system performance.

HYDRONIC MODULE
XP Energy hydronic module ensures a high level of comfort and energy saving. It is designed to t in a standard kitchen cabinet. Its main functions is to integrate dierent components, including the possibility to connect solar panels.

USER INTERFACE

CONDENSING UNIT
INVERTER TECHNOLOGY ADVANCED SYSTEM ELECTRONIC MANAGEMENT Two distinct electronic management logics optimise individual well-being with minimum energy consumption: Pulse Amplitude Modulation (PAM) of direct current to generate maximum power for the compressor at start-up and in peak load conditions. Pulse Width Modulation (PWM) of direct current optimises compressor eciency once the preset temperature has been reached, ensuring optimum comfort while saving energy. DC TWINROTARY COMPRESSOR Two rotary compression cylinders, oset from each other by 180, and a DC brushless motor with the shaft in perfect balance are used to reduce vibration and noise, even when operating at very low speeds.

The electronic control manage two independent temperature zone with their own programmable temperature settings. Calculates also the thermal inertia of the house as well as the evolution of the outdoor air temperature to create the required level of comfort. The two zone hydro module includes a 25 liters buer tank.

ECO COMFORT

LOWAMBIENT PERFORMANCE For the comfort of end-users, these heat pumps can work in extreme temperature conditions from 15 C to 46 C outdoor temperature.

LOW SOUND LEVELS XP Energy systems are very quiet. The outdoor units components drastically reduce any possible noise: fully insulated compressor, twin rotary cylinder shaft, component vibration suppression, fan design.

ACCESSORIES
Heat exchanger control for swimming pool heating Accumulative water tank for sanitary hot water production

VERY QUIET

QUIET

DISTURBING

Thermodynamic hot water tank (with heat pump) for sanitary water production

12

CARRIER HEATING SYSTEMS

13

Air to water split system Indoor unit Outdoor unit (HP) Nominal cooling capacity Minimum cooling capacity Maximum cooling capacity Nominal power input E.E.R. Energy eciency class (cooling mode) Nominal heating capacity Minimum heating capacity Maximum heating capacity Nominal power input C.O.P. Energy eciency class (heating mode)

Heating only
80AW1--H 38AW050H7 80AW1--H 38AW065H7 80AW2--H 38AW090H7 80AW2--H 38AW115H7 80AW1--X 38AW050H7

Heating and cooling


80AW1--X 38AW065H7 80AW2--X 38AW090H7 80AW2--X 38AW115H7

kW kW kW kW W/W kW kW kW kW W/W

5,00 1,17 5,86 1,13 4,41 A

6,53 0,86 8,81 1,51 4,32 A

9,10 1,61 14,75 2,07 4,40 A

11,50 1,77 15,43 2,71 4,24 A

4,23 0,76 5,62 1,16 3,65 A 5,00 1,17 5,86 1,13 4,41 A

5,59 1,03 7,55 1,53 3,65 A 6,53 0,86 8,81 1,51 4,32 A

7,88 2,15 11,4 1,95 4,05 A 9,10 1,61 14,75 2,07 4,40 A

9,00 2,46 13,02 2,37 3,80 A 11,50 1,77 15,43 2,71 4,24 A

Indoor unit Electric heater Electrical heaters back up Maximum comfort zones number Heater capacity, kW Boiler back up connection Heating only Heating and cooling Reversible Domestic hot water production

kW kW

Hydronic module matched with CDU 5 kW and 6,5 kW 80AW100H 80AW100X 80AW102H 80AW102X 80AW104H 2 2 4 12 12 22 1 1 1 1 1 1,0 1,0 1,2 1,2 1,4 yes yes yes yes yes yes yes yes yes yes yes yes Option Option Option Option Option

80AW104X 4 22 1 1,4 yes yes yes Option

80AW106H 6 23 1 1,6 yes yes Option

80AW106X 6 23 1 1,6 yes yes yes Option

Indoor unit Outdoor unit Nominal water ow Minimum water ow Maximum water ow Sound power (cooling mode) Sound power (heating mode) Dimensions (h l d) Weight Power supply

80AW1--lt/h lt/h lt/h dB(A) dB(A) mm kg V-ph-Hz 38AW050H7 860 688 1032 27 27 780/580/360 40 230-1-50 38AW065H7 1118 894 1342 38AW090H7 1548 1238 1358

80AW2--38AW115H7 1978 1582 2374 27 27 1050/560/522 80 230-1-50 Hydronic module matched with CDU 9 kW and 11,5 kW 80AW200H 80AW200X 80AW204H 80AW204X 80AW206H 4 4 6 22 22 23 2 2 2 2 2 2,0 2,0 2,4 2,4 2,6 yes yes yes yes yes yes yes yes yes yes yes yes yes yes Option Option Option Option Option

Outdoor unit (HP) Compressor type Maximum pipe length Maximum height dierence Chargeless Air ow (min / max) Air ow (min / max) Sound pressure (cooling mode) Sound power (cooling mode) Sound pressure (heating mode) Sound power (heating mode) Dimensions (h l d) Weight Flare connections Power supply

m m m l/sec m3/h dB(A) dB(A) dB(A) dB(A) mm kg in V-ph-Hz

38AW050H7 Twin Rotary 50 30 20 728 2620 44 64 44 64 690 900 320 49 1/4 1/2 230-1-50

38AW065H7 Twin Rotary 30 30 20 783 2820 45 65 48 68 820 900 320 51 3/8 5/8 230-1-50

38AW090H7 Twin Rotary 70 30 30 1658 5970 48 68 49 69 1360 900 320 88 3/8 5/8 230-1-50

38AW115H7 Twin Rotary 70 30 30 1767 6360 50 70 50 70 1360 900 320 88 3/8 5/8 230-1-50

Indoor unit Electric heater Electrical heaters back up Maximum comfort zones number Heater capacity, kW Boiler back up connection Heating only Heating and cooling Reversible Domestic hot water production

kW kW

80AW206X 6 23 2 2,6 yes yes yes Option

80AW208H 8 24 2 2,8 yes yes Option

80AW208X 8 24 2 2,8 yes yes yes Option

System size 50 65 90 115

Boiler backup yes yes

0 kW yes yes yes yes

2 kW yes yes -

Electric heater 4 kW yes yes yes yes

6 kW yes yes

8 kW yes yes

Code 80AW9009 OUTDOOR UNIT (air temperature) COOLING max min max 30 C db 45 C db 5 C db 24 C wb 17 C wb HEATING min 15 C db 18 C 4 C 55 C 20 C max INDOOR UNIT (water temperature) 80AW9010 COOLING min max HEATING min 80AW9011 80AW9019 80AW9020

Description Accumulative hot water tank for sanitary water production Thermodynamic hot water tank (with heat pump) for sanitary water production Heat exchanger plus control for swimming pool heating Electronic mixing valve zoning kit Direct zoning kit

A A B B

A 38AW050H7 mm mm mm mm 900 900 900 900 38AW065H7 38AW090H7 38AW115H7

B 690 820 1360 1360

C 320 320 320 320 49 51 88 88 80AW1--80AW2--mm mm

A 580 560

B 780 1050

C 360 522 40 80

14

CARRIER HEATING SYSTEMS

CARRIER HEATING SYSTEMS

15

www.carrier.com
September 2009 The manufacturer reserves the right to change the product specications, data and images without notice.

You might also like