Professional Documents
Culture Documents
TENTATIVE
High performance compact outdoor unit realizing high efficiency and comfort
Flexible multi system contains high-level functions in a compact body to comfortably control 8 rooms. An indoor unit connection capacity from 11.2 kW to 18.2 kW is possible, and indoor units with a capacity of 2.0 kW to 7.0 kW can be selected and combined to meet the application. Installation is easy and saves space, so we can recommend this system for a wide range of applications including community housing, single-unit residences, and stores.
System Outline
Compact outdoor unit 8 rooms multi Broad lineup of indoor unit
02
New model
Height difference
29%
1290mm
Compact and lightweight outdoor unit is easy to carry in. It can be installed in various obscure places.
914mm
EER
5 3 1 0
4.75
4.75
25
50
75
100
Part load(%)
DC fan motor : High performance and high efficiency has been realized by using a small DC fan motor. Heat exchanger : Reduced compact size and energy saving has been realized by utilizing high density piping design and 3-Row heat exchanger.
High efficiency DC twin rotary compressor : A high performance, low noise, large capacity DC twin rotary compressor is used.
More Comfort
Quick comfort by optimized refrigerant control
Every room meets set point most quickly and comfortably by optimized refrigerant control.
All operation start
Refrigerant control by branch box
Increase capacity
Decrease capacity
Increase capacity
Decrease capacity
03
SU MO TU WE TH FR SA
7
3 6 9 12 15 18 21
UTY-RNNYM
UTY-RSNYM
System configuration
Outdoor unit
Controllable
1 multi system
Max. Controllable
8 indoor units
Power & Transmission line Transmission line Remote controller cable
When the indoor units are connected to a branch box, the addresses for each indoor unit are set automatically.
*Note : Cross-over connections are not allowed in the refrigerant system. Group settings are not allowed.
04
User-friendly operation
Large backlight LED screen Large easy-to-see operation panel
UTY-DMMYM
Comfort control
10C heat operation
When you leave, minimum heating operation is performed to maintain the room temperature (maintain at 10C).
Convenience
Weekly schedule timer
The ON/OFF setting can be set for 4 times a day. Two weekly patterns can be set to match the cooling and heating seasons.
Monday~Friday Saturday~Sunday
20C
START 10C
Economy operation
Low noise operation
Users can choose from 4 low noise levels, depending on the installation environment. The operation time can be set using the timer.
Quiet priority setting
Shift setting temp Air conditioning load factor Set temperature Heat load
Economy operation is energy saving, as the set temperature of indoor unit is shifted by 1C and the maximum electric value of the outdoor unit is suppressed.
Temp.
Economy operation
Normal operation
down Time
Capacity
100% 0
Prohibited Settings
The remote controller operation of all indoor units comes with a lock function to prevent unapproved operations in the various rooms. The central remote controller also has a key lock function to prevent children from playing with it, etc
05
Flexible Design
A variety of installation patterns can be supported using the branch box connection method.
Examples Examples
Balcony
Bed Room 3
Living Room
Dining Area
Bed Room 2
1F
Bed Room 3 Bed Room 2 Kitchen Family Room Kitchen Family Room
Outdoor unit 2.5 kW Indoor unit 2.0 kW Indoor unit Branch box
Dining Room
Living Room
2F
115m max.
Height difference between O.U. and I.U.
70m max.
Branch box Separation tube
30m max.
Branch box
Ratio up to 130%
Up to 8
*At least 2 units must be connected.
15m max.
15m max.
06
Easy Installation
All flare piping connection and simple installation that minimizes wiring mistakes. Wiring mistake automatic check function
The check operation detects wiring mistakes in advance.
Branch box
Branch Box
Allowed Branch Box Mounting Direction Hanging from the ceiling
Do not hang from the ceiling when performing a vertical installation.
98 kg
Weight
Separation tube
Back Right
07
Outdoor unit
Specifications
Model name Maximum Connectable Indoor Unit Indoor unit connectable capacity Power source Rated Capacity Input Power Air flow rate Cooling Heating Cooling Heating Cooling Heating Cooling Heating kW m3/h Cooling kW V/ /Hz kW AOYG45LAT8 8 11.2 - 18.2 230/1/50 14.0 16.0 5.20 5.07 4,650 4,800 56 58 Plate fin coil mm kg(Ibs) mm m CDB 914 x970x370 98 (217) 9.52/15.88 115 (Total) -5 to 46 -15 to 24 R410A 30
Dimensions
Outdoor Unit AOYG45LAT8
370
(Unit : mm)
166 650
24
970
24 24
401 440
370
12
dB(A)
Piping Connections (Small / Large) Max Pipe Length Max Height Difference (O.U I.U) Operating range Refrigerant Cooling Heating
08
21
914
Class
7,000BTU 2.0kW
9,000BTU 2.5kW
12,000BTU 3.5kW
14,000BTU 4.0kW
18,000BTU 5.0kW
24,000BTU 7.0kW
Wall Mounted
ASYG18LFCA ASYG24LFCA
Floor
AGYG09LVCA AGYG12LVCA AGYG14LVCA
Floor / Ceiling
ABYG14LVTA ABYG18LVTA
Compact Cassette
AUYG07LVLA AUYG09LVLA AUYG12LVLA AUYG14LVLA AUYG18LVLA
Slim Duct
ARYG07LLTA ARYG09LLTA ARYG12LLTA ARYG14LLTA ARYG18LLTA
Feature Explanation
Comfortable function
Up / down swing flaps
The up/down flaps automatically swing up and down.
Convenient function
10C HEAT operation
The room temperature can be set to go no lower than 10C, thus ensuring that the room does not get too cold when not occupied.
Sleep timer
The micro-computer gradually changes the room temperature automatically to afford a comfortable night's sleep.
Auto restart
In the event of a temporary power failure, the air conditioner will automatically restart in the same operating mode as before, once the power supply is restored.
Economy mode
Limits the maximum operation current, and performs operation with the power consumption suppressed.
Program timer
This digital timer allows selection of one of four options: ON, OFF, ON OFF or OFF ON.
Clean function
Long-life ion deodorization filter
The filter deodorizes by powerfully decomposing absorbed odors using the oxidizing and reducing effects of ions generated by the ultra-fine-particle ceramic.
Filter sign
Indicates the filter cleaning period by lamp. To enable Filter sign, it has to be selected on the function setting.
Auto-changeover
The unit automatically switches between heating and cooling modes based on your temperature setting and the room temperature.
Apple-catechin filter
Fine dust, invisible mold spores, and harmful microorganisms are absorbed onto the filter by static electricity, and further growth is inhibited and deactivated by the polyphenol extracted from apples.
Washable panel
09
Wired R.C.
Optional
Wired R.C.
Wireless R.C.
Compact design
New model
790mm
The filter deodorizes by powerfully decomposing absorbed odors using the oxidizing and reducing effects of ions generated by the ultra-fine-particle ceramic.
280mm
*The filter can be used for approx. 3 years if it is washed under water to restore its surface action when it is dirty.
Apple-catechin filter
203mm
Fine dust, invisible mold spores, and harmful microorganisms are absorbed onto the filter by static electricity, and further growth is inhibited and deactivated by the polyphenol extracted from apples.
Easy maintenance
Removable & washable panel
7mm 5 mm
30%
Optional parts
Wired Remote Controller: Simple Remote Controller: External Connect Kit: Communication Kit: Apple Catechin Filter: Ion Deodorization Filter: UTY-RNNYM UTY-RSNYM UTY-XWZX UTY-XCBXZ1 UTR-FA16 (Replacement parts) UTR-FA16-2 (Replacement parts)
Specifications
Model No. Power source Air flow rate (C/H) High High Sound pressure level (C/H) Med Low Quiet Dimensions H x W x D Net Weight Liquid Gas mm kg(lbs) mm dB(A) V//Hz m3/h ASYG07LJCA 230/1/50 560/560 36/36 32/32 29/29 25/25 ASYG09LJCA 230/1/50 600/600 37/37 33/33 29/29 25/25 280790203 8(18) 6.35 9.52 ASYG12LJCA 230/1/50 660/660 40/40 36/36 30/31 25/25
10
Optional
Wired R.C.
Wireless R.C.
Vertical airflow provides powerful floor level heating & Horizontal airflow does not blow cool air directly at the occupants in the room
Vertical airflow *1
(24/30)
Easy maintenance
Simplification of drain pan cleaning improves maintenance-ability.
(C) 33 32 31 30 29
46o
Power diffuser (full open)
*1 : Outside air conditions: 2C 60% Operation contents: Heating, Set temperature (Max set temp) 30C, airflow Hi, Air direction downward and front
Horizontal airflow *2
(24/30)
Pre Filter
(C) 15 16 17 18
*2 : Outside air conditions: 35C 40% Operation contents: Cooling, Set temperature (Min set temp) 18C, airflow Hi, Air direction downward and front
Optional parts
Wired Remote Controller: Simple Remote Controller: External Connect Kit: Apple Catechin Filter: Ion Deodorization Filter: UTY-RNNYM UTY-RSNYM UTY-XWZX UTR-FA13-1 (Replacement parts) UTR-FA13-2 (Replacement parts)
Specifications
Model No. Power source Air flow rate (C/H) High High Sound pressure level (C/H) Med Low Quiet Dimensions H x W x D Net Weight Liquid Gas mm kg(lbs) mm 12.70 dB(A) V//Hz m3/h ASYG18LFCA 230/1/50 900/900 43/42 37/37 33/33 26/25 320998228 14(31) 6.35 15.88 ASYG24LFCA 230/1/50 1,100/1,120 47/48 42/42 37/37 32/32
11
Floor
Wired R.C.
Optional
Wired R.C.
Wireless R.C.
Filter features
Long-life* ion deodorization filter The filter deodorizes by powerfully decomposing absorbed odors using the oxidizing and reducing effects of ions generated by the ultra-fine-particle ceramic.
*The filter can be used for approx. 3 years if it is washed under water to restore its surface action when it is dirty. Using different filters at both sides Ion Deodorization Filter Apple-catechin Filter
at operation start
at stable operation
Apple-catechin filter
Fine dust, invisible mold spores, and harmful microorganisms are absorbed onto the filter by static electricity, and further growth is inhibited and deactivated by the polyphenol extracted from apples.
Heating
Window
Easy maintenance
Washable panel removable
Removable panel
at operation start
at stable operation
Piping
Wall
Optional parts
Wired Remote Controller: Simple Remote Controller: Half Concealed Kit: External Connect Kit: Apple Catechin Filter: Ion Deodorization Filter: UTY-RNNYM UTY-RSNYM UTR-STA UTY-XWZX UTR-FC03-2 (Replacement parts) UTR-FC03-3 (Replacement parts)
600
740
200
Max. 150
Min. 730
Max. 80
Specifications
Model No. Power source Air flow rate (C/H) High High Sound pressure level (C/H) Med Low Quiet Dimensions H x W x D Net Weight Liquid Gas mm kg(lbs) mm dB(A) V//Hz m3/h AGYG09LVCA 230/1/50 530/530 39/39 34/35 28/30 22/22 600740200 14(31) 6.35 9.52 12.70 AGYG12LVCA 230/1/50 600/600 42/42 36/38 30/32 22/22 AGYG14LVCA 230/1/50 650/650 44/44 38/39 31/33 22/22
12
Floor / Ceiling
ABYG14LVTA ABYG18LVTA
Optional
Optional
Wired R.C.
Wireless R.C.
Flexible installation
Example for floor installation Floor console
Easy installation
Main work settings can be done easily from the remote controller at installation
Main work settings High ceiling setting Auto restart Temperature adjustment when cooling / heating
2 1
5 steps selectable Steps Swing: Cooling , Dry and Fan mode Swing: Heating and Fan mode
7 steps selectable
(Optional parts)
Optional parts
Wired Remote Controller: UTY-RNNYM Simple Remote Controller: UTY-RSNYM External Connect Kit: UTY-XWZX
Specifications
Model No. Power source Air flow rate (C/H) High High Sound pressure level (C/H) Med Low Quiet Dimensions H x W x D Net Weight Liquid Gas mm kg(lbs) mm dB(A) V//Hz m3/h ABYG14LVTA 230/1/50 640/640 36/36 34/34 33/33 29/29 199990655 27(60) 6.35 12.70 ABYG18LVTA 230/1/50 780/780 41/41 38/38 34/34 32/32
13
Compact Cassette
AUYG07LVLA AUYG09LVLA AUYG12LVLA AUYG14LVLA AUYG18LVLA
Optional
Optional
Wired R.C.
Wireless R.C.
Grille is an option
Easy maintenance
1 Maintenance of fan motor and fan
Maintenance of the fan motor and fan can be done easily after taking off the panel as the bell mouth of the fan can be removed easily. A : Fan motor C : Bell-mouth B : 2-stage turbo fan D : Panel
1 A B C D
Quiet quality
Optimization of wing form (laminar wing type) and wing number (7 blades each)
Designed by CFD-analysis (fluid) simulations
Quiet Laminar wing Airflow runs through smoothly along the laminar wing
No airflow separation
3
Quiet
Adoption of laminar wing Spin direction Airflow direction
3 Adaptation of
Grille cover
Optional parts
Wired Remote Controller: Simple Remote Controller: Air Outlet Shutter Plate: Fresh Air Intake Kit: Insulation Kit For High Humidity: External Connect Kit: UTY-RNNYM UTY-RSNYM UTR-YDZB UTZ-VXAA UTZ-KXGC UTY-XWZX
Slow
20
%UP
Specifications
Model No. Power source Air flow rate (C/H) High High Sound pressure level (C/H) Med Low Quiet Dimensions H x W x D Net Weight Liquid Gas mm kg(lbs) mm 9.52 UTG-UFYD-W dB(A) V//Hz m3/h AUYG07LVLA 230/1/50 540/540 33/34 31/32 29/29 26/27 AUYG09LVLA 230/1/50 540/540 33/34 31/32 29/29 26/27 AUYG12LVLA 230/1/50 610/610 37/37 33/33 31/31 27/28 245570570 15(33) 6.35 12.70 AUYG14LVLA 230/1/50 680/700 40/40 35/37 32/34 27/29 AUYG18LVLA 230/1/50 750/800 42/44 37/41 33/37 27/30
14
Slim Duct
ARYG07LLTA ARYG09LLTA ARYG12LLTA ARYG14LLTA ARYG18LLTA
Slim design with drain pump Increase static pressure range Dual concealed type
Optional
Optional
Wireless R.C.
Wired R.C.
Slim design
This model is slim design, it can install at the place where a ceiling is narrow.
Drain port
Height
198mm
Drain pump built-in
Drain pump
Air-intake
Air intake direction can be selected to match the installation site.
Wired Remote Controller Wireles Remote Controller
Bottom side
Back side
Flexible installation
Ceiling concealed Floor concealed
0 to 90 Pa Optional parts
Max.
Simple Remote Controller: IR Receiver Unit: Remote Sensor Unit: External Control Set: Auto Louver Grille Kit
UTY-RSNYM UTY-LRHYM FUTURE RELEASE UTY-XSZX UTD-ECS5A UTD-GYSA (for ARYG07/09/12/14LATU) UTD-GYSB (for ARYG18LATU)
Specifications
Model No. Power source Air flow rate (C/H) Static pressure range High Sound pressure level (C/H) Med Low Quiet Dimensions H x W x D Net Weight Liquid Gas mm kg(lbs) mm 9.52 18(40) dB(A) High V//Hz m3/h Pa 28/28 25/25 24/24 22/22 28/28 27/26 26/25 25/24 198700620 19(41) 6.35 12.7 ARYG07LLTA 230/1/50 550/550 ARYG09LLTA 230/1/50 600/600 ARYG12LLTA 230/1/50 650/650 0 to 90 29/29 28/28 27/27 26/24 32/32 30/30 28/28 26/24 32/33 31/32 30/31 29/29 198900620 23(50) ARYG14LLTA 230/1/50 800/800 ARYG18LLTA 230/1/50 940/940
15
Optional Parts
Connection Units
Branch Box
UTP-PY03A UTP-PY02A
Separation tube
UTP-SX248A
3 zones type
2 zones type
Liquid pipe
Gas pipe
Controllers
Central Remote Controller
UTY-DMMYM
IR Receiver Unit
UTY-LRHYM For Slim Duct Type
Others
Grille Kit
UTG-UFYD-W For Compact Cassette type
UTR-YDZB For Compact Cassette Type Shuts the air outlet when only using as 3 blow out.
Communication Kit
UTY-XCBXZ1 For Compact Wall Mounted Type
ISO 9001 ISO 14001 Certified number : 01 100 89394 Certified number : 01 104 9245101
N807
All products specified in this brochure comply with the Australian Communications Authority's (ACA) requirements for Electromagnetic
The colors may be different from the actual colors because this catalog is printed matter. Product specifications are subject to change without notice. Distributed by :