Test Report No.

S09MEC06305lCLC
dated 29 SEPT 2009

Note: This repon is issued subject to TUV S i l o PSWs "Terms and Conditions Governing Technical Services". The termsand conditions governing the issue of this reparlare set out as atlached within this report.

PSB Singapore

SUBJECT:

Choose certainty. Add value.

Testing of TURBIDITY BARRIER GEOTAG SC200.

TESTED FOR: WALL TAG PTE LTD H I - 0 1 , BTH Centre, 23 Serangoon North Avenue 5, Singapore 554530 Attn : Mr. Peter Leong

DESCRIPTION OF SAMPLE: A set of material sample reference TURBIDITY BARRIER GEOTAG SC200 was received on 08 Sept 2009.

DATE OF TEST: 24 Sept 2009 to 29 Sept 2009

YO", - 0 ,

Mind

Laboratarf: TUV SUD PSB Re. ~ t d . Testing Sewices No.1 Science Palk DrNe Singapore 118221

Phone: +65-6885 1333 Fax : 465-6776 8670 E-mYI: lesiiig@luv-sud-p~b~~ w.1~~-sud-pb.sg Co. Reg : 199002667R

Reoional Head Office:


TUV S u O ~ s i a Pacific Re. Ltd.

3 Science Palk Dme, kO401105 The Franklin. Singapore 118223

m v '

Page 1 of 6

Test Report No. S09MEC06305lCLC


dated 29 SEPT 2009

PSB Singapore

METHOD OF TEST: 1. ASTM D4595 : 1986 (Reapproved 1994) Standard test method for tensile properties of geotextiles by the wide-width strip method. Specimen size Specimen condition Clamp type Grip distance Crosshead speed Machine used No. of tested specimen 2. 200mm (width) x 200mm (length) Dry Compressive clamp 1OOmm 1Ommlmin Zwick, 2100 5 per direction

ASTM D4884 : 1996 Standard test method for strength of sewn or thermally bonded seams of geotextiles. Specimen size Specimen condition Clamp type Grip distance Crosshead speed Machine used No. of stitch-line No. of tested specimen 200mm (Net width) x 320mm (length) Dr~ Compressive clamp IOOmm 10mmlrnin Zwick, Z100 6 5 per direction

3.

ASTM D4491: 96 Standard test method for water permeability of geotextiles by permittivity: Constant head test No. of tested specimen 5

4.

ASTM D4751: 95 Standard test method for determining apparent opening size of geotextiles. Shaker used No. of tested specimen Endecotts (Octagon 200) 5

TESTING CONDITIONS: ENIISO : 20 ASTM

+2 : 21 + 2

OC OC

/65.+ 5% RH 165 f 5% RH, unless otherwise specified

Test Report No. S09MEC06305lCLC


dated 29 SEPT 2009

PSB Singapore

TEST RESULTS: Table I - Wide-width tensile strength Test Unit TURBIDIN BARF'-GEOTAG SC2C

'

1(a).

Stdev

W~de-wldth tenslle strength (dry), average Machine d~rect~on kN/m 214.75 11.46

l(b)

Elongat~on at break, average Mach~ne d~rect~on


%

9.64

0.29

l Seam strength test Table I


V "

Tesl

Unit

Remarks *

28 75 2). Wide-w~dth seam strength (dry), Machine To Machine direction 34.27 kN/m 35.56 33.68 36.95 33.84 Seam rupture

Page 3 of 6

Test Report No. S09MEC06305lCLC


dated 29 SEPT 2009

PSB Singapore

TEST RESULTS (CON'T):

Table Ill -Water permittivity

IER GEOlTAG SC2C)O Tesr Unit


I

2
0.94 0.0469
3

1
0.0460

MOI~IYO

a~dev 0

C.V. (%) 7 91

Water permitt~vlty * Flow rate *

S'

0.79 0.0394

0.93 0.0465

i9 0 0447

m/s

* : Calculated based on 2 0 ' ~ water and 50mm water head, refer to flgure 1.

Test Report No. S09MEC063051CLC


dated 29 SEPT 2009

PSB Sngapore

TEST RESULTS (CON'T):

Table IV
?

- Apparent opening size


TURBIDITY BAlPRIER G E

~.~

~~

. , .. .
llnit

1
34.08

-.
Specimen weight Apparent opening size, 0 9 5 Average g mm mm

2 34.00

0.075

34.24 34.16 34.1 0

0.075

0.075

0.075

0.075

Remark: C.V. - coefficient of variation in percentage Stdev - standard deviation

Associate Engineer

Product Manager Industrial & Polymer Products Mechanical Centre

Page 5 of 6

Test Report No. S09MEC06305lCLC


dated 29 SEPT 2009
PSB Singapore

This Report is issued under Ule following conditions: 1. 2. Results of the testinglcalibrationin the form of a report will be issued immediately after the service has been completed or terminated. Unless otherwise requested, a report shall contain only technical resulk. Analysis and interpretation of the results and pmfesslonal opinion and recommendations expressed thereupon, if required, shall be clearly indicated and additional fee paid for, by the Ciient. indicate or imply that they are applicable to other similar items. In addition, such results must not be used to indicate or imply that TUV SUD PSB approves, recommends or endorses the manufacturer, supplier or user of such productiequipment, or that TUV SUD PSB in any way 'Quamntees"the later peffomlance of the productiequipment.
4.

3. This report applies to the sample of the specific product/equipmen! given at the time of its testingicaiibration The results are not used to

The samplels mentioned in this report islare submittedisuppliedimanutactured by the Client. TUV SOD PSB therefore assumes no responsibility for the accumcy of information on the brand name, model number, origin of manufacture, consignment or any inlormation supplied. Additional copies of the report are available to the Client at an additional fee. No third party can obtain a copy of this report through TUV SUD PSB, unless the Client has authorised TUV SUD PSB in writing to do so.
TUV SUD PSB may at its sole discretion add to or amend the conditions of the report at the time of issue of the report and such report and such additions or amendments shall be binding on the Cl~ent.

5.
6.

7.

All copyright in the report shall remain with TUV SOD PSB and the Client shall, upon payment of TUV SUD PSB's lees for the carrying out of the tests/calibrations, be aranted a license to use or oublish the reDort to the third oarties subiect tothe terms and conditions herein, provlded always that TUV SUD PSB may at its absolute discretion be entilleb to impose such conditions on the license as it sees fit Noth~ng in this report shall be interpreted to mean that TL~VSUD PSB has verified or ascertained any endorsement or marks from any other testing authority or bodies that may be found on that sample. This report shall not be reproduced wholly or in parts and no reference shall be made by the Ciient to TljV SLID PSB or to the report or results furnished by TUV SUD PSB in any advertisements or sales promotion.

8. 9.

10. Unless otherwise stated, the tests are carried out in TUV SUD PSB Pte Ltd. No.1 Science Park Dlive Singapore 118221.

March 2009

Page 6 of 6