M ODEL Automatic Blood Pressure Monitor


60 sets Memory
with Date & Time

dP
r B l o o re s s u
You sion Is A Sile re Re
r en ssage brough nt
t e K
erlth m d OMRON Healthto y
t
M o n it o

gu

n
il l eby
H yp

Ia c
ou re

la rl y
a
He

a
YJ

Fully automatic inflation and deflation

Fuzzy logic

Large display, easy to read

Displays average of up to last 3 readings taken within 10 minutes


from most recent measurement

Durable fan-shaped cuff

60 sets memory with date & time


Battery low symbol to alert users to replace batteries

created by joko sutantiyo joko@nautiza.com www.nautiza.com


The Omron SEM-2 automatic blood pressure monitor uses oscillometric method of blood pressaure
measurement. This means the monitor detects your blood’s movement through your brachial artery
and converts the movements into a digital reading. An oscillometric monitor does not need a stethoscope
so the monitor is easy to use.

Average function
Omron SEM-2 displays the average of up to last 3 readings taken within 10 minutes from recent
measurement, i.e. If 2 or 3 readings are taken within 10 minutes, the respective average of last 2 or
3 readings are displayed. If only 1 reading is taken within 10 minutes, this reading would be displayed
as the average value. This feature enables the user to track any variation within a short time interval.

Easy measurement for special conditions


If the systolic pressure is known to be more than 220 mmHg, press and hold START/STOP button until
the arm cuff inflates 30 to 40 mmHg higher than the suspected systolic pressure.

How to avoid incorrect blood pressure measurement ?


1. Avoid eating, smoking, and exercising for at least 30 minutes before taking a measurement.
Also rest for at least 15 minutes before taking your first reading.
2. Stress raises blood pressure. Avoid taking measurements during stressful times.
3. Remove tight-fitting clothing from your left upper arm
4. Measurement should be taken in a quiet place and you should be in relaxed, seated position.
5. Rest your left arm on the arm of a chair or on table so that the cuff is at the same level as your heart.
Remain still and do not talk during the measurement.
6. Do not take a measurement after bathing, alcohol or exercise.

WHO Blood Pressure Classification


The World Health Organization (WHO)/ International Society of Hypertention (ISH) developed
the following Blood Pressure Classification, to be used as a general guidline only.
Systolic (mmHg) Diastolic (mmHg)
Optimal less than 120 less than 80
Normal 120 to 129 80 to 84
High-Normal 130 to 139 85 to 89
Grade 1 hypertension (mild) 140 to 159 90 to 99
Grade 2 hypertension (moderate) 160 to 179 100 to 109
Grade 3 hypertension (severe) more than 180 more than 110
There is no universally accepted definition of hypotension (low blood pressure), but a systolic pressure below 99 mmHg is usually regarded as hypotension.

SPECIFICATIONS
Display LCD Digital Display
Measurement Range Pressure: 0 to 299 mmHg, Pulse : 40 to 180 beats/min
Accuracy/Calibration Pressure: Within +3mmHg, Pulse rate: Within +5% of reading
Power Source 4 “AA” batteries (or AC Adapter)
Battery Life Approx. 1500 uses when used twice a day with new “AA” alkaline batteries
Main Unit Weight Approx. 340g not including batteries
Main Unit Dimensions Approx. 121mm (w) x 86mm (h) x 141mm (I)
External Dimensions Approx. 146mm (w) 446mm (I), Cuff tube 600mm (I)
Measurable Circumference of Wrist Fits arm circumferences 220mm to 320mm
Contents Main unit, Arm cuff, Storage case, 4 “AA” Alkaline batteries, Instruction manual

NOTE: These specifications are subject to change without notice.