Table of Contents
81-Series
82-Series
83-Series
84-Series
85-Series
86-Series
Misc.
81-Series
Section Contents
81-Series
Commercial & Light Industrial
Pre-Insulated Pipe Supports
Page(s)
Pictorial Selection Guide
A-B
1-13
Fig.
BP8110
BP8120
BP8130
BP8140
BP8150
BP8160
BP8170
BP8172
BP8174
BP8180
BP8182
BP8184
BP8190
Light
Light
Medium
Medium
Medium
Medium
Heavy
Heavy
X-Heavy
Heavy
Heavy
X-Heavy
Heavy
1
2
3
4
5
6
7
8
9
10
11
12
13
81-Series
81-Series
Fig.
Pipe Size
Range
BP8110
BP8120
BP8130
BP8130
BP8140
BP8140
BP8190
1/2 - 24
1/2 - 24
1/2 - 4
1/2 - 24
1/2 - 4
1/2 - 24
1/2 - 24
For Installation On
Load
Class
Page
Light
Light
Light
Medium
Medium
Medium
Heavy
1
2
3
3
4
4
13
CLEVIS HANGER
PIPE CRADLES
ROLL
FLAT SURFACE
81-Series
81-Series
Fig.
Pipe Size
Range
BP8150
BP8160
BP8170
BP8172
BP8174
BP8180
BP8182
BP8184
2 1/2 - 42
2 1/2 - 42
2 1/2 - 42
6 - 42
10 - 30
2 1/2 - 42
6 - 42
10 - 30
For Installation On
Load
Class
Page
Medium
Medium
Heavy
Heavy
X-Heavy
Heavy
Heavy
X-Heavy
5
6
7
8
9
10
11
12
ROLL
FLAT SURFACE
BP8110
Fig. BP8110
Design Data
Temperature Range: +40F to +1200F
Higher temperatures available upon
request.
Insulation: Calcium Silicate asbestos
free, treated with water repellant.
Jackets: Galvanized Steel ASTM A-527
Glue: Industrial contact adhesive
Load Rating:
For process systems operating at
500F or greater, multiply the load
rating in the chart by the following
factors:
500 = .90, 750 = .75, 1000 = .50,
1200 = .30
To develop maximum load rating,
width of support surface should be
at least 1/2 of dimension A.
For higher load ratings, see
BP8130, BP8190.
Maximum Load
Ratings (lbs)
Insulation Thickness
1/2
3/4
1 1/2
2 1/2
3 1/2
Pipe
On Flat
In Clevis
Size
Surface
Hanger
1/2
3/4
1
1 1/4
1 1/2
2
2 1/2
3
3 1/2
4
5
6
8
10
12
14
16
18
20
24
40
50
60
80
110
140
170
200
250
300
380
440
490
540
600
620
650
680
730
810
50
60
70
90
120
160
220
270
330
380
490
600
810
1080
1300
1510
1730
1940
2160
2480
4
4
4
4
4
6
6
6
6
6
-
24
24
24
24
24
24
20
20
20
20
-
4
4
4
4
4
6
6
6
6
6
-
24
24
24
24
24
24
20
20
20
20
-
4
4
4
4
4
6
6
6
6
6
6
6
-
24
24
24
24
24
24
20
20
20
20
20
20
-
4
4
4
4
4
6
6
6
6
6
6
6
9
9
12
12
12
12
18
18
24
24
24
24
24
24
20
20
20
20
20
20
16
16
16
16
16
16
16
16
4
4
4
4
4
6
6
6
6
6
6
6
9
9
12
12
12
12
18
18
24
24
24
24
24
24
20
20
20
20
20
20
16
16
16
16
16
16
16
16
4
4
4
4
4
6
6
6
6
6
6
6
9
9
12
12
12
12
18
18
24
24
24
24
24
24
20
20
20
20
20
20
16
16
16
16
16
16
16
16
6
6
6
6
6
6
9
9
9
9
9
9
9
9
12
12
12
12
18
18
24
24
24
24
24
24
20
20
20
20
20
16
16
16
16
16
16
16
16
16
6
6
6
6
6
6
9
9
9
9
9
9
9
9
12
12
12
12
18
18
24
24
24
24
24
24
20
20
20
20
20
16
16
16
16
16
16
16
16
16
6
6
6
6
6
6
9
9
9
9
9
9
9
9
12
12
12
12
18
18
24
24
24
24
24
24
20
20
20
20
20
16
16
16
16
16
16
16
16
16
Copper
Tubing Size
OD
5/8
7/8
1 1/8
1 3/8
1 5/8
2 1/8
2 5/8
3 1/8
3 5/8
4 1/8
5 1/8
6 1/8
8 1/8
10 1/8
12 1/8
The load ratings represent average values obtained in accordance with accepted methods and are subject to normal manufacturing variations.
---- Dimensions and ratings are subject to change without notice. ----
Easy Installation
Order Information: Specify Quantity Pipe Size & Type Insulation Thickness Figure Number
1
Fig. BP8120
BP8120
Design Data
Temperature Range: +40F to +1200F
Higher temperatures available upon
request.
Insulation: Calcium Silicate asbestos
free, treated with water repellant.
Jackets: Galvanized Steel ASTM A-527
Glue: Industrial contact adhesive
Load Rating:
For process systems operating at
500F or greater, multiply the load
rating in the chart by the following
factors:
500 = .90, 750 = .75, 1000 = .50,
1200 = .30
To develop maximum load rating,
width of support surface should be
at least 1/2 of dimension A.
For higher load ratings, see
BP8140, BP8190.
Pipe
Size
1/2
3/4
1
1 1/4
1 1/2
2
2 1/2
3
3 1/2
4
5
6
8
10
12
14
16
18
20
24
Maximum Load
Ratings (lbs)
On Flat In Clevis
Surface
Hanger
40
50
60
80
110
140
170
200
250
300
380
440
490
540
600
620
650
680
730
810
50
60
70
90
120
160
220
270
330
380
490
600
810
1080
1300
1510
1730
1940
2160
2480
Insulation Thickness
1 1/2
2
2 1/2
A
B
A
B
A
B
6
6
6
6
6
6
6
6
6
6
-
24
24
24
24
24
24
20
20
20
20
-
6
6
6
6
6
6
6
6
6
6
-
24
24
24
24
24
24
20
20
20
20
-
6
6
6
6
6
6
6
6
6
6
6
6
-
24
24
24
24
24
24
20
20
20
20
20
20
-
6
6
6
6
6
6
6
6
6
6
6
6
9
9
12
12
12
12
18
18
1/2
3/4
24
24
24
24
24
24
20
20
20
20
20
20
16
16
16
16
16
16
16
16
6
6
6
6
6
6
6
6
6
6
6
6
9
9
12
12
12
12
18
18
24
24
24
24
24
24
20
20
20
20
20
20
16
16
16
16
16
16
16
16
6
6
6
6
6
6
6
6
6
6
6
6
9
9
12
12
12
12
18
18
24
24
24
24
24
24
20
20
20
20
20
20
16
16
16
16
16
16
16
16
3
A
6
6
6
6
6
6
9
9
9
9
9
9
9
9
12
12
12
12
18
18
3 1/2
A
B
24
24
24
24
24
24
20
20
20
20
20
16
16
16
16
16
16
16
16
16
6
6
6
6
6
6
9
9
9
9
9
9
9
9
12
12
12
12
18
18
6
6
6
6
6
6
9
9
9
9
9
9
9
9
12
12
12
12
18
18
24
24
24
24
24
24
20
20
20
20
20
16
16
16
16
16
16
16
16
16
24
24
24
24
24
24
20
20
20
20
20
16
16
16
16
16
16
16
16
16
Copper
Tubing
Size OD
5/8
7/8
1 1/8
1 3/8
1 5/8
2 1/8
2 5/8
3 1/8
3 5/8
4 1/8
5 1/8
6 1/8
8 1/8
10 1/8
12 1/8
The load ratings represent average values obtained in accordance with accepted methods and are subject to normal manufacturing variations.
---- Dimensions and ratings are subject to change without notice. ----
Easy Installation
Order Information: Specify Quantity Pipe Size & Type Insulation Thickness Figure Number
BP8130
Fig. BP8130
Design Data
Temperature Range: +40F to +1200F
Higher temperatures available upon
request.
Insulation: Calcium Silicate asbestos
free, treated with water repellant.
Jackets: Galvanized Steel ASTM A-527
Glue: Industrial contact adhesive
Load Rating:
For process systems operating at
500F or greater, multiply the load
rating in the chart by the following
factors:
500 = .90, 750 = .75, 1000 = .50,
1200 = .30
To develop maximum load rating,
width of support surface should be
at least 1/2 of dimension A.
For higher load ratings, see
BP8150, BP8190.
Insulation Thickness
Maximum Load Ratings (lbs)
1/2
3/4
1 1/2
2 1/2
3 1/2
Pipe
On Flat
On Pipe
Clevis
Size
Surface
Roll
Hanger
50
55
70
90
120
160
180
220
270
330
440
490
540
570
620
650
680
700
760
840
40
50
65
80
110
140
170
200
250
300
55
60
75
100
130
170
240
300
350
410
520
620
870
1190
1400
1620
1830
2050
2260
2590
4
4
4
4
4
6
6
6
6
6
-
20
20
20
20
20
20
18
18
18
18
-
4
4
4
4
4
6
6
6
6
6
-
20
20
20
20
20
20
18
18
18
18
-
4
4
4
4
4
6
6
6
6
6
6
6
-
20
20
20
20
20
20
18
18
18
18
16
16
-
4
4
4
4
4
6
6
6
6
6
6
6
9
9
12
12
12
12
18
18
20
20
20
20
20
20
18
18
18
18
16
16
14
14
14
14
12
12
12
12
4
4
4
4
4
6
6
6
6
6
6
6
9
9
12
12
12
12
18
18
20
20
20
20
20
20
18
18
18
18
16
16
14
14
14
14
12
12
12
12
4
4
4
4
4
6
6
6
6
6
6
6
9
9
12
12
12
12
18
18
20
20
20
20
20
20
18
18
18
18
16
16
14
14
14
14
12
12
12
12
6
6
6
6
6
6
9
9
9
9
9
9
9
9
12
12
12
12
18
18
20
20
20
20
20
20
18
18
18
18
16
16
14
14
14
14
12
12
12
12
6
6
6
6
6
6
9
9
9
9
9
9
9
9
12
12
12
12
18
18
20
20
20
20
20
20
18
18
18
18
16
16
14
14
14
14
12
12
12
12
6
6
6
6
6
6
9
9
9
9
9
9
9
9
12
12
12
12
18
18
20
20
20
20
20
20
18
18
18
18
16
16
14
14
14
14
12
12
12
12
1/2
3/4
1
1 1/4
1 1/2
2
2 1/2
3
3 1/2
4
5
6
8
10
12
14
16
18
20
24
See
BP8150
The load ratings represent average values obtained in accordance with accepted methods and are subject to normal manufacturing variations.
---- Dimensions and ratings are subject to change without notice. ----
Easy Installation
Order Information: Specify Quantity Pipe Size & Type Insulation Thickness Figure Number
3
Copper
Tubing
Size OD
5/8
7/8
1 1/8
1 3/8
1 5/8
2 1/8
2 5/8
3 1/8
3 5/8
4 1/8
5 1/8
6 1/8
8 1/8
10 1/8
12 1/8
Fig. BP8140
BP8140
Design Data
Temperature Range: +40F to+1200F
Higher temperatures available upon
request.
Insulation: Calcium Silicate asbestos
free, treated with water repellant.
Jackets: Galvanized Steel ASTM A-527
Glue: Industrial contact adhesive
Load Rating:
For process systems operating at
500F or greater, multiply the load
rating in the chart by the following
factors:
500 = .90, 750 = .75, 1000 = .50,
1200 = .30
To develop maximum load rating,
width of support surface should be
at least 1/2 of dimension A.
For higher load ratings, see
BP8160, BP8190.
Insulation Thickness
3/4
1 1/2
2 1/2
3 1/2
Pipe
On Flat
On Pipe
Clevis
Size
Surface
Roll
Hanger
50
55
70
90
120
160
180
220
270
330
440
490
540
570
620
650
680
700
760
840
40
50
65
80
110
140
170
200
250
300
55
60
75
100
130
170
240
300
350
410
520
620
870
1190
1400
1620
1830
2050
2260
2590
6
6
6
6
6
6
6
6
6
6
-
20
20
20
20
20
20
18
18
18
18
-
6
6
6
6
6
6
6
6
6
6
-
20
20
20
20
20
20
18
18
18
18
-
6
6
6
6
6
6
6
6
6
6
6
6
-
20
20
20
20
20
20
18
18
18
18
16
16
-
6
6
6
6
6
6
6
6
6
6
6
6
9
9
12
12
12
12
18
18
20
20
20
20
20
20
18
18
18
18
16
16
14
14
14
14
12
12
12
12
6
6
6
6
6
6
6
6
6
6
6
6
9
9
12
12
12
12
18
18
20
20
20
20
20
20
18
18
18
18
16
16
14
14
14
14
12
12
12
12
6
6
6
6
6
6
6
6
6
6
6
6
9
9
12
12
12
12
18
18
20
20
20
20
20
20
18
18
18
18
16
16
14
14
14
14
12
12
12
12
6
6
6
6
6
6
9
9
9
9
9
9
9
9
12
12
12
12
18
18
20
20
20
20
20
20
18
18
18
18
16
16
14
14
14
14
12
12
12
12
6
6
6
6
6
6
9
9
9
9
9
9
9
9
12
12
12
12
18
18
20
20
20
20
20
20
18
18
18
18
16
16
14
14
14
14
12
12
12
12
6
6
6
6
6
6
9
9
9
9
9
9
9
9
12
12
12
12
18
18
20
20
20
20
20
20
18
18
18
18
16
16
14
14
14
14
12
12
12
12
1/2
3/4
1
1 1/4
1 1/2
2
2 1/2
3
3 1/2
4
5
6
8
10
12
14
16
18
20
24
See
BP8160
Copper
Tubing Size
OD
5/8
7/8
1 1/8
1 3/8
1 5/8
2 1/8
2 5/8
3 1/8
3 5/8
4 1/8
5 1/8
6 1/8
8 1/8
10 1/8
12 1/8
The load ratings represent average values obtained in accordance with accepted methods and are subject to normal manufacturing variations.
---- Dimensions and ratings are subject to change without notice. ----
Easy Installation
Order Information: Specify Quantity Pipe Size & Type Insulation Thickness Figure Number
BP8150
Fig. BP8150
Design Data
Temperature Range: +40F to +1200F
Higher temperatures available upon
request.
Insulation: Calcium Silicate asbestos
free, treated with water repellant.
Jackets: Galvanized Steel ASTM A-527
Glue: Industrial contact adhesive
Load Distribution Plate: Carbon steel
ASTM A-36
Coating: Primer coated or hot-dip
galvanized. Other coatings available
upon request.
Load Rating:
For process systems operating at
500F or greater, multiply the load
rating in the chart by the following
factors:
500 = .90, 750 = .75, 1000 = .50,
1200 = .30
To develop maximum load rating,
width of support surface should be
at least 1/2 of dimension B.
For higher load ratings, see
BP8170, BP8180.
Pipe
Size
2 1/2
3
3 1/2
4
5
6
8
10
12
14
16
18
20
24
30
36
42
220
270
330
380
490
540
680
700
1000
1080
1190
1300
1400
1510
1620
1620
1620
200
250
300
340
440
490
600
620
890
970
1050
1160
1240
1350
1460
1460
1460
9
9
9
9
9
9
9
9
12
12
12
12
12
12
12
12
12
6
6
6
6
6
6
6
6
9
9
9
9
9
9
9
9
9
1/4
1/4
1/4
1/4
1/4
1/4
1/4
1/4
3/8
3/8
1/2
1/2
1/2
3/4
3/4
3/4
3/4
Max. Axial
Travel
(inches)
on
Pipe Roll
+/-
2
2
2
2
2
2
2
2
3
3
3
3
3
3
3
3
3
The load ratings represent average values obtained in accordance with accepted methods and are subject to normal manufacturing variations.
---- Dimensions and ratings are subject to change without notice. ----
Easy Installation
Order Information: Specify Quantity Pipe Size & Type Insulation Thickness Figure Number
5
Fig. BP8160
BP8160
Design Data
Temperature Range: +40F to +1200F
Higher temperatures available upon
request.
Insulation: Calcium Silicate asbestos
free, treated with water repellant.
Jackets: Galvanized Steel ASTM A-527
Glue: Industrial contact adhesive
Load Distribution Plate: Carbon steel
ASTM A-36
Coating: Primer coated or hot-dip
galvanized. Other coatings available
upon request.
Load Rating:
For process systems operating at
500F or greater, multiply the load
rating in the chart by the following
factors:
500 = .90, 750 = .75, 1000 = .50,
1200 = .30
To develop maximum load rating,
width of support surface should be
at least 1/2 of dimension B.
For higher load ratings, see
BP8170, BP8180.
Pipe
Size
2 1/2
3
3 1/2
4
5
6
8
10
12
14
16
18
20
24
30
36
42
220
270
330
380
490
540
680
700
1000
1080
1190
1300
1400
1510
1620
1620
1620
200
250
300
340
440
490
600
620
890
970
1050
1160
1240
1350
1460
1460
1460
9
9
9
9
9
9
9
9
12
12
12
12
12
12
12
12
12
6
6
6
6
6
6
6
6
9
9
9
9
9
9
9
9
9
1/4
1/4
1/4
1/4
1/4
1/4
1/4
1/4
3/8
3/8
1/2
1/2
1/2
3/4
3/4
3/4
3/4
Max. Axial
Travel
(inches)
on
Pipe Roll
+/-
2
2
2
2
2
2
2
2
3
3
3
3
3
3
3
3
3
The load ratings represent average values obtained in accordance with accepted methods and are subject to normal manufacturing variations.
---- Dimensions and ratings are subject to change without notice. ----
Easy Installation
Order Information: Specify Quantity Pipe Size & Type Insulation Thickness Figure Number
BP8170
Fig. BP8170
Design Data
Temperature Range: +40F to +1200F
Higher temperatures available upon
request.
Insulation: Calcium Silicate asbestos
free, treated with water repellant.
Structural Inserts: High-density
calcium silicate asbestos-free, treated
with water repellant.
Load Distribution Plate: Carbon steel
ASTM A-36
Coating: Primer coated or hot-dip
galvanized. Other coatings available
upon request.
Jackets: Galvanized Steel ASTM A-527
Glue: Industrial contact adhesive
Load Rating:
To develop maximum load rating,
width of support surface should be
at least 1/2 of dimension B.
For higher load ratings, see
BP8172, BP8174, BP8210-Series.
On Flat Surface
2 1/2
3
3 1/2
4
5
6
8
10
12
14
16
18
20
24
30
36
42
270
330
380
440
540
600
760
950
1730
1780
1990
2160
2260
2480
2690
2690
2690
6
6
6
6
6
6
6
9
9
9
9
9
9
9
9
9
9
3
3
3
3
3
3
3
6
6
6
6
6
6
6
6
6
6
1/4
1/4
1/4
1/4
1/4
1/4
1/4
3/8
3/8
3/8
1/2
1/2
1/2
3/4
3/4
3/4
3/4
The load ratings represent average values obtained in accordance with accepted methods and are subject to normal manufacturing variations.
---- Dimensions and ratings are subject to change without notice. ----
Easy Installation
Order Information: Specify Quantity Pipe Size & Type Insulation Thickness Figure Number
7
Fig. BP8172
BP8172
Design Data
Temperature Range: +40F to +1200F
Higher temperatures available
upon request.
Insulation: Calcium Silicate
asbestos free, treated with water
repellant.
Structural Inserts:
High-density
calcium silicate asbestos-free, treated with
water repellant.
Load Distribution Plate: Carbon steel
ASTM A-36
Coating: Primer coated or hot-dip
galvanized. Other coatings
available upon request.
Jackets: Galvanized Steel ASTM A-527
Glue: Industrial contact adhesive
Load Rating:
To develop maximum load
rating, width of support surface
should be at least 1/2 of
dimension B.
For higher load ratings, see
BP8174, BP8210-Series.
Intended for installation on flat surfaces.
Order Hardware Separately - see Hardware Catalog 98H.
Pipe
Size
Maximum Load
Ratings (lbs)
A
9
9
9
9
9
9
9
9
9
9
9
9
6
6
6
6
6
6
6
6
6
6
6
6
1/2
1/2
5/8
5/8
5/8
3/4
3/4
3/4
1
1
1
1
On Flat Surface
6
8
10
12
14
16
18
20
24
30
36
42
1080
1350
1670
2420
2990
3550
3880
4090
4410
4840
4840
4840
The load ratings represent average values obtained in accordance with accepted methods and are subject to normal manufacturing variations.
---- Dimensions and ratings are subject to change without notice. ----
Easy Installation
Order Information: Specify Quantity Pipe Size & Type Insulation Thickness Figure Number
BP8174
Fig. BP8174
Design Data
Temperature Range: +40F to +1200F
Higher temperatures available
upon request.
Insulation: Calcium Silicate
asbestos free, treated with water
repellant.
Structural Inserts:
High-density
calcium silicate asbestos-free,
treated with water repellant.
Load Distribution Plate: Carbon
steel ASTM A-36
Coating: Primer coated or hot-dip
galvanized. Other coatings
available upon request.
Jackets: Galvanized Steel ASTM A-527
Glue: Industrial contact adhesive
Load Rating:
To develop maximum load rating,
width of support surface should be
at least 1/2 of dimension B.
For higher load ratings, see
BP8210-Series.
Pipe
Size
Maximum Load
Ratings (lbs)
A
9
9
9
9
9
9
9
9
6
6
6
6
6
6
6
6
3/4
3/4
3/4
1
1
1
1
1
On Flat Surface
10
12
14
16
18
20
24
30
2260
3660
4200
4740
5170
5490
5920
5920
The load ratings represent average values obtained in accordance with accepted methods and are subject to normal manufacturing variations.
---- Dimensions and ratings are subject to change without notice. ----
Easy Installation
Order Information: Specify Quantity Pipe Size & Type Insulation Thickness Figure Number
9
Fig. BP8180
BP8180
Design Data
Temperature Range: +40F to +1200F
Higher temperatures available upon
request.
Insulation: Calcium Silicate
asbestos free, treated with water
repellant.
Structural Inserts:
High-density
calcium silicate asbestos-free,
treated with water repellant.
Load Distribution Plate: Carbon
steel ASTM A-36
Coating: Primer coated or hot-dip
galvanized. Other coatings
available upon request.
Jackets: Galvanized Steel ASTM A-527
Glue: Industrial contact adhesive
Note:
For higher load ratings, see
BP8182, BP8184, BP8210-Series
Pipe
Size
Maximum
Load Ratings
(lbs)
A
9
9
9
9
9
9
9
12
12
12
12
12
12
12
12
12
12
6
6
6
6
6
6
6
9
9
9
9
9
9
9
9
9
9
1/4
1/4
1/4
1/4
1/4
1/4
1/4
3/8
3/8
3/8
1/2
1/2
1/2
3/4
3/4
3/4
3/4
On Pipe Roll
2 1/2
3
3 1/2
4
5
6
8
10
12
14
16
18
20
24
30
36
42
250
270
330
380
490
540
680
950
1510
1590
1780
1940
2020
2210
2420
2420
2420
Max. Axial
Travel
(Inches)
on
Pipe Roll
2
2
2
2
2
2
2
4
4
4
4
4
4
4
4
4
4
The load ratings represent average values obtained in accordance with accepted methods and are subject to normal manufacturing variations.
---- Dimensions and ratings are subject to change without notice. ----
Easy Installation
Order Information: Specify Quantity Pipe Size & Type Insulation Thickness Figure Number
10
BP8182
Fig. BP8182
Design Data
Temperature Range: +40F to +1200F
Higher temperatures available
upon request.
Insulation: Calcium Silicate
asbestos free, treated with water
repellant.
Structural Inserts:
High-density
calcium silicate asbestos-free,
treated with water repellant.
Load Distribution Plate: Carbon
steel ASTM A-36
Coating: Primer coated or hot-dip
galvanized. Other coatings
available upon request.
Jackets: Galvanized Steel ASTM A-527
Glue: Industrial contact adhesive
Note:
For higher load ratings, see
BP8184, BP8210-Series.
Pipe
Size
Maximum
Load Ratings
(lbs)
A
12
12
12
12
12
12
12
12
12
12
12
12
9
9
9
9
9
9
9
9
9
9
9
9
1/2
1/2
5/8
5/8
5/8
3/4
3/4
3/4
1
1
1
1
On Pipe Roll
6
8
10
12
14
16
18
20
24
30
36
42
970
1210
1480
2750
2850
3180
3450
3630
3960
4360
4360
4360
Max. Axial
Travel
(Inches)
on
Pipe Roll
3
3
3
3
3
3
3
3
3
3
3
3
The load ratings represent average values obtained in accordance with accepted methods and are subject to normal manufacturing variations.
---- Dimensions and ratings are subject to change without notice. ----
Easy Installation
Order Information: Specify Quantity Pipe Size & Type Insulation Thickness Figure Number
11
Fig. BP8184
BP8184
Design Data
Temperature Range: +40F to +1200F
Higher temperatures available
upon request.
Insulation: Calcium Silicate
asbestos free, treated with water
repellant.
Structural Inserts:
High-density
calcium silicate asbestos-free,
treated with water repellant.
Load Distribution Plate: Carbon
steel ASTM A-36
Coating: Primer coated or hot-dip
galvanized. Other coatings
available upon request.
Jackets: Galvanized Steel ASTM A-527
Glue: Industrial contact adhesive
Note:
For higher load ratings, see
BP8210-Series.
Pipe
Size
Maximum
Load Ratings
(lbs)
A
12
12
12
12
12
12
12
12
9
9
9
9
9
9
9
9
1
1
1
1
1
1
1
1
On Pipe Roll
10
12
14
16
18
20
24
30
2020
3660
3770
4250
4630
4900
5330
5870
Max. Axial
Travel
(Inches)
on
Pipe Roll
2 1/4
2 1/4
2 1/4
2 1/4
2 1/4
2 1/4
2 1/4
2 1/4
The load ratings represent average values obtained in accordance with accepted methods and are subject to normal manufacturing variations.
---- Dimensions and ratings are subject to change without notice. ----
Easy Installation
Order Information: Specify Quantity Pipe Size & Type Insulation Thickness Figure Number
12
BP8190
Fig. BP8190
Design Data
Temperature Range: +40F to +1200F
Higher temperatures available
upon request.
Insulation: Calcium Silicate
asbestos free, treated with water
repellant.
Structural Inserts:
High-density
calcium silicate asbestos-free,
treated with water repellant.
Jackets: Galvanized Steel ASTM A-527
Glue: Industrial contact adhesive
Note:
For higher load ratings, see
BP8210-Series.
Maximum Load
Ratings (lbs)
Pipe
Size
1/2
3/4
1
1 1/4
1 1/2
2
2 1/2
3
3 1/2
4
5
6
8
10
12
14
16
18
20
24
Insulation Thickness
3/4
1/2
Clevis
1 1/2
2 1/2
3 1/2
Hanger
60
60
90
110
140
190
270
330
380
440
600
650
970
1300
1560
1780
2050
2320
2590
2960
4
4
4
4
4
6
6
6
6
6
-
24
24
24
24
24
24
20
20
20
20
-
4
4
4
4
4
6
6
6
6
6
-
24
24
24
24
24
24
20
20
20
20
-
4
4
4
4
4
6
6
6
6
6
6
6
-
24
24
24
24
24
24
20
20
20
20
20
20
-
4
4
4
4
4
6
6
6
6
6
6
6
9
9
12
12
12
12
18
18
24
24
24
24
24
24
20
20
20
20
20
20
16
16
16
16
16
16
16
16
4
4
4
4
4
6
6
6
6
6
6
6
9
9
12
12
12
12
18
18
24
24
24
24
24
24
20
20
20
20
20
20
16
16
16
16
16
16
16
16
4
4
4
4
4
6
6
6
6
6
6
6
9
9
12
12
12
12
18
18
24
24
24
24
24
24
20
20
20
20
20
20
16
16
16
16
16
16
16
16
6
6
6
6
6
6
9
9
9
9
9
9
9
9
12
12
12
12
18
18
24
24
24
24
24
24
20
20
20
20
20
16
16
16
16
16
16
16
16
16
6
6
6
6
6
6
9
9
9
9
9
9
9
9
12
12
12
12
18
18
24
24
24
24
24
24
20
20
20
20
20
16
16
16
16
16
16
16
16
16
6
6
6
6
6
6
9
9
9
9
9
9
9
9
12
12
12
12
18
18
24
24
24
24
24
24
20
20
20
20
20
16
16
16
16
16
16
16
16
16
Copper
Tubing Size
OD
The load ratings represent average values obtained in accordance with accepted methods and are subject to normal manufacturing variations.
---- Dimensions and ratings are subject to change without notice. ----
Easy Installation
Order Information: Specify Quantity Pipe Size & Type Insulation Thickness Figure Number
13
5/8
7/8
1 1/8
1 3/8
1 5/8
2 1/8
2 5/8
3 1/8
3 5/8
4 1/8
5 1/8
6 1/8
8 1/8
10 1/8
12 1/8
Section Contents
82-Series
Page(s)
Pictorial Selection Guide
A-B
1-32
Fig.
BP8210
BP8211
BP8212
BP8213
BP8220
BP8221
BP8222
BP8223
BP8230
BP8231
BP8232
BP8233
BP8240
BP8241
BP8242
BP8243
BP8250
BP8251
BP8252
BP8253
BP8260
BP8261
BP8262
BP8263
Light
Medium
Heavy
X-Heavy
Light
Medium
Heavy
X-Heavy
Light
Medium
Heavy
X-Heavy
Light
Medium
Heavy
X-Heavy
Light
Medium
Heavy
X-Heavy
Light
Medium
Heavy
X-Heavy
contd on reverse
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
82-Series
Section Contents
82-Series
Heavy Industrial Pre-Insulated Pipe Slides & Guides
(contd)
82-Series
Page(s)
Fig.
BP8270
BP8271
BP8272
BP8273
BP8280
BP8281
BP8282
BP8283
Light
Medium
Heavy
X-Heavy
Light
Medium
Heavy
X-Heavy
25
26
27
28
29
30
31
32
82-Series
Fig.
Load
Class
Page
BP8210
BP8211
BP8212
BP8213
1.5
1.5
1.5
1.5
0.5
0.5
0.5
0.5
N/A
N/A
N/A
N/A
Light
Medium
Heavy
X-Heavy
1
2
3
4
BP8220
BP8221
BP8222
BP8223
4.5
4.5
4.5
4.5
0.5
0.5
0.5
0.5
N/A
N/A
N/A
N/A
Light
Medium
Heavy
X-Heavy
5
6
7
8
BP8230
BP8231
BP8232
BP8233
1.5
1.5
1.5
1.5
0
0
0
0
YES
YES
YES
YES
Light
Medium
Heavy
X-Heavy
9
10
11
12
BP8240
BP8241
BP8242
BP8243
4.5
4.5
4.5
4.5
0
0
0
0
YES
YES
YES
YES
Light
Medium
Heavy
X-Heavy
13
14
15
16
82-Series
Order Information: Specify Quantity Pipe Size & Type Insulation Thickness Figure Number
82-Series
82-Series
Fig.
Load
Class
Page
BP8250
BP8251
BP8252
BP8253
1.5
1.5
1.5
1.5
1.5 - 4.5
1.5 - 4.5
1.5 - 4.5
1.5 - 4.5
N/A
N/A
N/A
N/A
Light
Medium
Heavy
X-Heavy
17
18
19
20
BP8260
BP8261
BP8262
BP8263
4.5
4.5
4.5
4.5
1.5 - 4.5
1.5 - 4.5
1.5 - 4.5
1.5 - 4.5
N/A
N/A
N/A
N/A
Light
Medium
Heavy
X-Heavy
21
22
23
24
BP8270
BP8271
BP8272
BP8273
1.5
1.5
1.5
1.5
0
0
0
0
w/ Slide Pads
w/ Slide Pads
w/ Slide Pads
w/ Slide Pads
Light
Medium
Heavy
X-Heavy
25
26
27
28
BP8280
BP8281
BP8282
BP8283
4.5
4.5
4.5
4.5
0
0
0
0
w/ Slide Pads
w/ Slide Pads
w/ Slide Pads
w/ Slide Pads
Light
Medium
Heavy
X-Heavy
29
30
31
32
Order Information: Specify Quantity Pipe Size & Type Insulation Thickness Figure Number
B
Fig. BP8210
Design Data
BP8210
Temperature Range
Range: +40F to +1200F
Higher temperatures available upon
request.
Insulation: Calcium Silicate asbestos
free, treated with water repellant.
Jackets: Galvanized Steel ASTM A-527.
Glue: Industrial contact adhesive.
Structural inserts: High-density
calcium silicate asbestos free, treated
with water repellant.
Steel Straps/Base: Carbon Steel
ASTM A-36.
Fasteners: ASTM A-307 plated.
Slide Pad: UHMW Polyethylene (Teflon
Optional).
Coating: Primer coated or hot dipped
galvanized. Other coatings available
upon request.
Note:
For higher load ratings, see BP8211
For greater axial travel, see BP8220
For lateral restraint, see BP8230
For lateral travel, see BP8250
1" Thk.
1 1/2" Thk.
2" Thk.
Pipe Vert.
Size Load B C
E
B C
E
B C
E
160 4 1.5
3.25 4
2
4.375 4 2.5
5.375
1/2
190 4 1.5
3.25 4
2
4.375 4 2.5
5.375
3/4
250 4
2
3.875 4 2.5
4.875 4
3
5.937
1
2
4.375 4 2.5
5.5 4
4
7
1 1/2 350 4
410
4
2.5
5
4
3
6.0625
4
4
7
2
5.5 4
4
7.125 4 4.5
8.125
2 1/2 500 4 2.5
570 4
3
6.062 4
4
7.125 4 4.5
8.125
3
910 4
4
7.25 4 4.5
8.25 4 5.5
9.25
4
1130 4 4.5
8.25 4 5.5
9.25 4 6.5
10.25
5
1380 4 5.5
9.25 4 6.5
10.25 4 7.5 11.375
6
1830 4 7.5 11.625 4
8 12.625 4
9 13.625
8
2160 4
9 13.625 4 9.5 14.875 4 10.5 15.875
10
2370 4 10.5 16.125 4
11 17.125 4
12 18.125
12
2690 4
11 17.125 4
12 18.125 4 12.5 19.125
14
3120 4 12.5 19.125 4
13 20.125 6
14 21.375
16
3450
4
14
21.375
4
14.5
22.375
6
15.5
23.375
18
3660 4 15.5 23.375 4
16 24.375 6 16.5 25.375
20
3880 4
18 27.375 4
19 28.375 6 19.5 29.375
24
5060 4 22.5 33.625 6
23 34.625 6
24 35.625
30
5920 4 26.5 39.625 6 27.5 41.125 6
28 42.125
36
6670 4
31 46.125 6 31.5 47.125 6 32.5 48.125
42
B
4
4
4
4
4
4
4
4
4
4
6
6
6
6
6
6
6
6
6
6
6
2 1/2" Thk.
C
E
4
4
4
4.5
4.5
5.5
5.5
6.5
7.5
8
9.5
11
12.5
13
14.5
16
17.5
20.5
24.5
28.5
33
7
7
7
8
8
9.125
9.125
10.25
11.375
12.625
14.875
16.875
19.125
20.125
22.375
24.375
26.375
30.375
36.625
43.125
49.125
3" Thk.
C
E
4" Thk.
C
E
5" Thk.
C
E
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
4.5
4.5
4.5
5.5
5.5
6.5
6.5
7.5
8
9
10.5
12
13
14
15.5
16.5
18
21
25
29.5
33.5
6
6
6
6
6
6
6
6
6
6
6
6
6
6
8
8
8
8
8
8
8
6.5
6.5
6.5
7.5
7.5
8
8
9
9.5
10.5
12
13
14.5
15.5
16.5
18
19.5
22.5
26.5
31
35
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
9
9
9.5
9.5
10.5
11
12
13
14.5
16
16.5
18
19.5
21
24
28
32.5
36.5
8
8
8
9
9.125
10.125
10.125
11.375
12.375
13.625
15.875
18.125
20.125
21.125
23.375
25.375
27.375
31.375
37.625
44.125
50.125
10
10
10
11.25
11.25
12.25
12.375
13.375
14.875
15.875
17.875
20.125
22.125
23.125
25.375
27.375
29.375
33.375
39.625
46.125
52.125
12.125
12.125
12.25
13.25
13.25
14.5
14.625
15.625
16.875
17.875
20.125
22.125
24.125
25.125
27.375
29.375
31.375
35.375
41.625
48.125
54.125
The load ratings represent average values obtained in accordance with accepted methods and are subject to normal manufacturing variations.
---- Dimensions and ratings are subject to change without notice. ----
Easy Installation
Order Information: Specify Quantity Pipe Size & Type Insulation Thickness Figure Number
Fig. BP8211
BP8211
Design Data
Temperature Range
Range: +40F to +1200F
Higher temperatures available upon
request.
Insulation: Calcium Silicate asbestos
free, treated with water repellant.
Jackets: Galvanized Steel ASTM A-527.
Glue: Industrial contact adhesive.
Structural inserts: High-density
calcium silicate asbestos free, treated
with water repellant.
Steel Straps/Base: Carbon Steel
ASTM A-36.
Fasteners: ASTM A-307 plated.
Slide Pad: UHMW Polyethylene (Teflon
Optional).
Coating: Primer coated or hot dipped
galvanized. Other coatings available
upon request.
Note:
For higher load ratings, see BP8212
For greater axial travel, see BP8221
For lateral restraint, see BP8231
For lateral travel, see BP8251
Pipe
Size
1/2
3/4
1
1 1/2
2
2 1/2
3
4
5
6
8
10
12
14
16
18
20
24
30
36
42
Vert.
Load B
310
380
490
700
810
990
1140
1810
2260
2750
3660
4310
4740
5380
6240
6890
7320
7750
10110
11830
13340
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
1" Thk.
C
E
1.5
1.5
2
2
2.5
2.5
3
4
4.5
5.5
7.5
9
10.5
11
12.5
14
15.5
18
22.5
26.5
31
3.25
3.25
3.875
4.5
5
5.5
6.187
7.25
8.5
9.5
11.625
13.875
16.125
17.125
19.375
21.375
23.375
27.375
33.625
40.125
46.125
1 1/2" Thk.
C
E
2" Thk.
C
E
4 2
4.375 4 2.5
4 2
4.375 4 2.5
4 2.5
5
4 3
4 2.5
5.5
4 4
4 3
6.0625 4 4
4 4
7.125 4 4.5
4 4
7.125 4 4.5
4 4.5
8.25 4 5.5
4 5.5
9.5
4 6.5
4 6.5
10.5 4 7.5
4 8
12.625 4 9
4 9.5 15.125 4 10.5
4 11 17.125 4 12
4 12 18.125 4 12.5
4 13 20.375 6 14
4 14.5 22.375 6 15.5
4 16 24.375 6 16.5
4 19 28.375 6 19.5
6 23 34.625 6 24
6 27.5 41.125 6 28
6 31.5 47.125 6 32.5
5.375
5.375
6.062
7.125
7.125
8.125
8.125
9.25
10.5
11.625
13.625
16.125
18.125
19.125
21.375
23.375
25.375
29.375
35.625
42.125
48.125
2 1/2" Thk.
C
E
4
4
4
4
4
4
4
4
4
4
6
6
6
6
6
6
6
6
6
6
6
4
4
4
4.5
4.5
5.5
5.5
6.5
7.5
8
9.5
11
12.5
13
14.5
16
17.5
20.5
24.5
28.5
33
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
7
7
7
8.125
8.125
9.125
9.125
10.25
11.625
12.625
14.875
17.125
19.125
20.125
22.375
24.375
26.375
30.375
36.625
43.125
49.125
3" Thk.
C
E
4.5
4.5
4.5
5.5
5.5
6.5
6.5
7.5
8
9
10.5
12
13
14
15.5
16.5
18
21
25
29.5
33.5
8
8
8
9.125
9.125
10.125
10.125
11.375
12.625
13.625
15.875
18.125
20.125
21.125
23.375
25.375
27.375
31.375
37.625
44.125
50.125
B
6
6
6
6
6
6
6
6
6
6
6
6
6
6
8
8
8
8
8
8
8
4" Thk.
C
E
6.5
6.5
6.5
7.5
7.5
8
8
9
9.5
10.5
12
13
14.5
15.5
16.5
18
19.5
22.5
26.5
31
35
10
10
10
11.25
11.25
12.25
12.375
13.375
14.875
15.875
18.125
20.125
22.125
23.125
25.375
27.375
29.375
33.375
39.625
46.125
52.125
B
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
5" Thk.
C
E
8
8
8
9
9
9.5
9.5
10.5
11
12
13
14.5
16
16.5
18
19.5
21
24
28
32.5
36.5
The load ratings represent average values obtained in accordance with accepted methods and are subject to normal manufacturing variations.
---- Dimensions and ratings are subject to change without notice. ----
Easy Installation
Order Information: Specify Quantity Pipe Size & Type Insulation Thickness Figure Number
2
12.125
12.25
12.25
13.25
13.25
14.5
14.625
15.625
16.875
17.875
20.125
22.125
24.125
25.125
27.375
29.375
31.375
35.375
41.625
48.125
54.125
Fig. BP8212
Design Data
BP8212
Temperature Range
Range: +40F to +1200F
Higher temperatures available upon
request.
Insulation: Calcium Silicate asbestos
free, treated with water repellant.
Jackets: Galvanized Steel ASTM A-527.
Glue: Industrial contact adhesive.
Structural inserts: High-density
calcium silicate asbestos free, treated
with water repellant.
Steel Straps/Base: Carbon Steel
ASTM A-36.
Fasteners: ASTM A-307 plated
Slide Pad: UHMW Polyethylene (Teflon
Optional).
Coating: Primer coated or hot dipped
galvanized. Other coatings available
upon request.
Note:
For higher load ratings, see BP8213
For greater axial travel, see BP8222
For lateral restraint, see BP8232
For lateral travel, see BP8252
Pipe
Size
1/2
3/4
1
1 1/2
2
2 1/2
3
4
5
6
8
10
12
14
16
18
20
24
30
36
42
Vert.
Load B
440
540
700
1030
1190
1460
1730
2690
3340
4090
5490
6460
7100
8070
9360
10330
10970
11620
15170
17750
20000
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
1" Thk.
C
E
1.5
1.5
2
2
2.5
2.5
3
4
4.5
5.5
7.5
9
10.5
11
12.5
14
15.5
18
22.5
26.5
31
3.25
3.25
3.875
4.5
5
5.5
6.187
7.25
8.5
9.5
11.625
13.875
16.125
17.125
19.375
21.375
23.375
27.375
33.625
40.125
46.125
1 1/2" Thk.
C
E
2" Thk.
C
E
4 2
4.375 4 2.5
4 2
4.375 4 2.5
4 2.5
5
4 3
4 2.5
5.5
4 4
4 3
6.0625 4 4
4 4
7.125 4 4.5
4 4
7.125 4 4.5
4 4.5
8.25 4 5.5
4 5.5
9.5
4 6.5
4 6.5
10.5 4 7.5
4 8
12.625 4 9
4 9.5 15.125 4 10.5
4 11 17.125 4 12
4 12 18.125 4 12.5
4 13 20.375 6 14
4 14.5 22.375 6 15.5
4 16 24.375 6 16.5
4 19 28.375 6 19.5
6 23 34.625 6 24
6 27.5 41.125 6 28
6 31.5 47.125 6 32.5
5.375
5.375
6.062
7.125
7.125
8.125
8.125
9.25
10.5
11.625
13.625
16.125
18.125
19.125
21.375
23.375
25.375
29.375
35.625
42.125
48.125
2 1/2" Thk.
C
E
4
4
4
4
4
4
4
4
4
4
6
6
6
6
6
6
6
6
6
6
6
4
4
4
4.5
4.5
5.5
5.5
6.5
7.5
8
9.5
11
12.5
13
14.5
16
17.5
20.5
24.5
28.5
33
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
7
7
7
8.125
8.125
9.125
9.125
10.25
11.625
12.625
14.875
17.125
19.125
20.125
22.375
24.375
26.375
30.375
36.625
43.125
49.125
3" Thk.
C
E
4.5
4.5
4.5
5.5
5.5
6.5
6.5
7.5
8
9
10.5
12
13
14
15.5
16.5
18
21
25
29.5
33.5
8
8
8
9.125
9.125
10.125
10.125
11.375
12.625
13.625
15.875
18.125
20.125
21.125
23.375
25.375
27.375
31.375
37.625
44.125
50.125
B
6
6
6
6
6
6
6
6
6
6
6
6
6
6
8
8
8
8
8
8
8
4" Thk.
C
E
6.5
6.5
6.5
7.5
7.5
8
8
9
9.5
10.5
12
13
14.5
15.5
16.5
18
19.5
22.5
26.5
31
35
10
10
10
11.25
11.25
12.25
12.375
13.375
14.875
15.875
18.125
20.125
22.125
23.125
25.375
27.375
29.375
33.375
39.625
46.125
52.125
B
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
5" Thk.
C
E
8
8
8
9
9
9.5
9.5
10.5
11
12
13
14.5
16
16.5
18
19.5
21
24
28
32.5
36.5
12.125
12.25
12.25
13.25
13.25
14.5
14.625
15.625
16.875
17.875
20.125
22.125
24.125
25.125
27.375
29.375
31.375
35.375
41.625
48.125
54.125
The load ratings represent average values obtained in accordance with accepted methods and are subject to normal manufacturing variations.
---- Dimensions and ratings are subject to change without notice. ----
Easy Installation
Order Information: Specify Quantity Pipe Size & Type Insulation Thickness Figure Number
Fig. BP8213
BP8213
Design Data
Temperature Range
Range: +40F to +1200F
Higher temperatures available upon
request.
Insulation: Calcium Silicate asbestos
free, treated with water repellant.
Jackets: Galvanized Steel ASTM A-527.
Glue: Industrial contact adhesive.
Structural inserts: High-density
calcium silicate asbestos free, treated
with water repellant.
Steel Straps/Base: Carbon Steel
ASTM A-36.
Fasteners: ASTM A-307 plated
Slide Pad: UHMW Polyethylene (Teflon
Optional).
Coating: Primer coated or hot dipped
galvanized. Other coatings available
upon request.
Note:
For greater axial travel, see BP8223
For lateral restraint, see BP8233
For lateral travel, see BP8253
Pipe
Size
1/2
3/4
1
1 1/2
2
2 1/2
3
4
5
6
8
10
12
14
16
18
20
24
30
36
42
Vert.
Load B
600
760
970
1400
1620
1940
2260
3610
4520
5490
7320
8610
9470
10760
12480
13770
14630
15490
20220
23660
26670
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
1" Thk.
C
E
1.5
1.5
2
2
2.5
2.5
3
4
4.5
5.5
7.5
9
10.5
11
12.5
14
15.5
18
22.5
26.5
31
3.25
3.25
3.875
4.5
5
5.5
6.187
7.25
8.5
9.5
11.625
13.875
16.125
17.125
19.375
21.375
23.375
27.375
33.625
40.125
46.125
1 1/2" Thk.
C
E
2" Thk.
C
E
4 2
4.375 4 2.5
4 2
4.375 4 2.5
4 2.5
5
4 3
4 2.5
5.5
4 4
4 3
6.0625 4 4
4 4
7.125 4 4.5
4 4
7.125 4 4.5
4 4.5
8.25 4 5.5
4 5.5
9.5
4 6.5
4 6.5
10.5 4 7.5
4 8
12.625 4 9
4 9.5 15.125 4 10.5
4 11 17.125 4 12
4 12 18.125 4 12.5
4 13 20.375 6 14
4 14.5 22.375 6 15.5
4 16 24.375 6 16.5
4 19 28.375 6 19.5
6 23 34.625 6 24
6 27.5 41.125 6 28
6 31.5 47.125 6 32.5
5.375
5.375
6.062
7.125
7.125
8.125
8.125
9.25
10.5
11.625
13.625
16.125
18.125
19.125
21.375
23.375
25.375
29.375
35.625
42.125
48.125
2 1/2" Thk.
C
E
4
4
4
4
4
4
4
4
4
4
6
6
6
6
6
6
6
6
6
6
6
4
4
4
4.5
4.5
5.5
5.5
6.5
7.5
8
9.5
11
12.5
13
14.5
16
17.5
20.5
24.5
28.5
33
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
7
7
7
8.125
8.125
9.125
9.125
10.25
11.625
12.625
14.875
17.125
19.125
20.125
22.375
24.375
26.375
30.375
36.625
43.125
49.125
3" Thk.
C
E
4.5
4.5
4.5
5.5
5.5
6.5
6.5
7.5
8
9
10.5
12
13
14
15.5
16.5
18
21
25
29.5
33.5
8
8
8
9.125
9.125
10.125
10.125
11.375
12.625
13.625
15.875
18.125
20.125
21.125
23.375
25.375
27.375
31.375
37.625
44.125
50.125
B
6
6
6
6
6
6
6
6
6
6
6
6
6
6
8
8
8
8
8
8
8
4" Thk.
C
E
6.5
6.5
6.5
7.5
7.5
8
8
9
9.5
10.5
12
13
14.5
15.5
16.5
18
19.5
22.5
26.5
31
35
10
10
10
11.25
11.25
12.25
12.375
13.375
14.875
15.875
18.125
20.125
22.125
23.125
25.375
27.375
29.375
33.375
39.625
46.125
52.125
B
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
5" Thk.
C
E
8
8
8
9
9
9.5
9.5
10.5
11
12
13
14.5
16
16.5
18
19.5
21
24
28
32.5
36.5
The load ratings represent average values obtained in accordance with accepted methods and are subject to normal manufacturing variations.
---- Dimensions and ratings are subject to change without notice. ----
Easy Installation
Order Information: Specify Quantity Pipe Size & Type Insulation Thickness Figure Number
4
12.125
12.25
12.25
13.25
13.25
14.5
14.625
15.625
16.875
17.875
20.125
22.125
24.125
25.125
27.375
29.375
31.375
35.375
41.625
48.125
54.125
Fig. BP8220
Design Data
BP8220
Temperature Range
Range: +40F to +1200F
Higher temperatures available upon
request.
Insulation: Calcium Silicate asbestos
free, treated with water repellant.
Jackets: Galvanized Steel ASTM A-527.
Glue: Industrial contact adhesive.
Structural inserts: High-density
calcium silicate asbestos free, treated
with water repellant.
Steel Straps/Base: Carbon Steel
ASTM A-36.
Fasteners: ASTM A-307 plated
Slide Pad: UHMW Polyethylene (Teflon
Optional).
Coating: Primer coated or hot dipped
galvanized. Other coatings available
upon request.
Note:
For higher load ratings, see BP8221
For lateral restraint, see BP8240
For lateral travel, see BP8260
Pipe
Size
1/2
3/4
1
1 1/2
2
2 1/2
3
4
5
6
8
10
12
14
16
18
20
24
30
36
42
Vert.
Load B
160
190
250
350
410
500
570
910
1130
1380
1830
2160
2370
2690
3120
3450
3660
3880
5060
5920
6670
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
1" Thk.
C
E
1.5
1.5
2
2
2.5
2.5
3
4
4.5
5.5
7.5
9
10.5
11
12.5
14
15.5
18
22.5
26.5
31
3.25
3.25
3.875
4.375
5
5.5
6.062
7.25
8.25
9.25
11.625
13.625
16.125
17.125
19.125
21.375
23.375
27.375
33.625
39.625
46.125
1 1/2" Thk.
C
E
2" Thk.
C
E
4 2
4.375 4 2.5
4 2
4.375 4 2.5
4 2.5 4.875 4 3
4 2.5
5.5
4 4
4 3
6.0625 4 4
4 4
7.125 4 4.5
4 4
7.125 4 4.5
4 4.5
8.25 4 5.5
4 5.5
9.25 4 6.5
4 6.5 10.25 4 7.5
4 8
12.625 4 9
4 9.5 14.875 4 10.5
4 11 17.125 4 12
4 12 18.125 4 12.5
4 13 20.125 6 14
4 14.5 22.375 6 15.5
4 16 24.375 6 16.5
4 19 28.375 6 19.5
6 23 34.625 6 24
6 27.5 41.125 6 28
6 31.5 47.125 6 32.5
5.375
5.375
5.937
7
7
8.125
8.125
9.25
10.25
11.375
13.625
15.875
18.125
19.125
21.375
23.375
25.375
29.375
35.625
42.125
48.125
4
4
4
4
4
4
4
4
4
4
6
6
6
6
6
6
6
6
6
6
6
2 1/2" Thk.
C
E
4
4
4
4.5
4.5
5.5
5.5
6.5
7.5
8
9.5
11
12.5
13
14.5
16
17.5
20.5
24.5
28.5
33
7
7
7
8
8
9.125
9.125
10.25
11.375
12.625
14.875
16.875
19.125
20.125
22.375
24.375
26.375
30.375
36.625
43.125
49.125
B
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
3" Thk.
C
E
4.5
4.5
4.5
5.5
5.5
6.5
6.5
7.5
8
9
10.5
12
13
14
15.5
16.5
18
21
25
29.5
33.5
8
8
8
9
9.125
10.125
10.125
11.375
12.375
13.625
15.875
18.125
20.125
21.125
23.375
25.375
27.375
31.375
37.625
44.125
50.125
B
6
6
6
6
6
6
6
6
6
6
6
6
6
6
8
8
8
8
8
8
8
4" Thk.
C
E
6.5
6.5
6.5
7.5
7.5
8
8
9
9.5
10.5
12
13
14.5
15.5
16.5
18
19.5
22.5
26.5
31
35
10
10
10
11.25
11.25
12.25
12.375
13.375
14.875
15.875
17.875
20.125
22.125
23.125
25.375
27.375
29.375
33.375
39.625
46.125
52.125
B
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
5" Thk.
C
E
8
8
8
9
9
9.5
9.5
10.5
11
12
13
14.5
16
16.5
18
19.5
21
24
28
32.5
36.5
12.125
12.125
12.25
13.25
13.25
14.5
14.625
15.625
16.875
17.875
20.125
22.125
24.125
25.125
27.375
29.375
31.375
35.375
41.625
48.125
54.125
The load ratings represent average values obtained in accordance with accepted methods and are subject to normal manufacturing variations.
---- Dimensions and ratings are subject to change without notice. ----
Easy Installation
Order Information: Specify Quantity Pipe Size & Type Insulation Thickness Figure Number
Fig. BP8221
BP8221
Design Data
Temperature Range
Range: +40F to +1200F
Higher temperatures available upon
request.
Insulation: Calcium Silicate asbestos
free, treated with water repellant.
Jackets: Galvanized Steel ASTM A-527.
Glue: Industrial contact adhesive.
Structural inserts: High-density
calcium silicate asbestos free, treated
with water repellant.
Steel Straps/Base: Carbon Steel
ASTM A-36.
Fasteners: ASTM A-307 plated.
Slide Pad: UHMW Polyethylene (Teflon
Optional).
Coating: Primer coated or hot dipped
galvanized. Other coatings available
upon request.
Note:
For higher load ratings, see BP8222
For lateral restraint, see BP8231
For lateral travel, see BP8251
Pipe
Size
1/2
3/4
1
1 1/2
2
2 1/2
3
4
5
6
8
10
12
14
16
18
20
24
30
36
42
Vert.
Load B
310
380
490
700
810
990
1140
1810
2260
2750
3660
4310
4740
5380
6240
6890
7320
7750
10110
11830
13340
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
1" Thk.
C
E
1.5
1.5
2
2
2.5
2.5
3
4
4.5
5.5
7.5
9
10.5
11
12.5
14
15.5
18
22.5
26.5
31
3.25
3.25
3.875
4.5
5
5.5
6.187
7.25
8.5
9.5
11.625
13.875
16.125
17.125
19.375
21.375
23.375
27.375
33.625
40.125
46.125
1 1/2" Thk.
C
E
2" Thk.
C
E
4 2
4.375 4 2.5
4 2
4.375 4 2.5
4 2.5
5
4 3
4 2.5
5.5
4 4
4 3
6.0625 4 4
4 4
7.125 4 4.5
4 4
7.125 4 4.5
4 4.5
8.25 4 5.5
4 5.5
9.5
4 6.5
4 6.5
10.5 4 7.5
4 8
12.625 4 9
4 9.5 15.125 4 10.5
4 11 17.125 4 12
4 12 18.125 4 12.5
4 13 20.375 6 14
4 14.5 22.375 6 15.5
4 16 24.375 6 16.5
4 19 28.375 6 19.5
6 23 34.625 6 24
6 27.5 41.125 6 28
6 31.5 47.125 6 32.5
5.375
5.375
6.062
7.125
7.125
8.125
8.125
9.25
10.5
11.625
13.625
16.125
18.125
19.125
21.375
23.375
25.375
29.375
35.625
42.125
48.125
2 1/2" Thk.
C
E
4
4
4
4
4
4
4
4
4
4
6
6
6
6
6
6
6
6
6
6
6
4
4
4
4.5
4.5
5.5
5.5
6.5
7.5
8
9.5
11
12.5
13
14.5
16
17.5
20.5
24.5
28.5
33
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
7
7
7
8.125
8.125
9.125
9.125
10.25
11.625
12.625
14.875
17.125
19.125
20.125
22.375
24.375
26.375
30.375
36.625
43.125
49.125
3" Thk.
C
E
4.5
4.5
4.5
5.5
5.5
6.5
6.5
7.5
8
9
10.5
12
13
14
15.5
16.5
18
21
25
29.5
33.5
8
8
8
9.125
9.125
10.125
10.125
11.375
12.625
13.625
15.875
18.125
20.125
21.125
23.375
25.375
27.375
31.375
37.625
44.125
50.125
B
6
6
6
6
6
6
6
6
6
6
6
6
6
6
8
8
8
8
8
8
8
4" Thk.
C
E
6.5
6.5
6.5
7.5
7.5
8
8
9
9.5
10.5
12
13
14.5
15.5
16.5
18
19.5
22.5
26.5
31
35
10
10
10
11.25
11.25
12.25
12.375
13.375
14.875
15.875
18.125
20.125
22.125
23.125
25.375
27.375
29.375
33.375
39.625
46.125
52.125
B
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
5" Thk.
C
E
8
8
8
9
9
9.5
9.5
10.5
11
12
13
14.5
16
16.5
18
19.5
21
24
28
32.5
36.5
The load ratings represent average values obtained in accordance with accepted methods and are subject to normal manufacturing variations.
---- Dimensions and ratings are subject to change without notice. ----
Easy Installation
Order Information: Specify Quantity Pipe Size & Type Insulation Thickness Figure Number
6
12.125
12.25
12.25
13.25
13.25
14.5
14.625
15.625
16.875
17.875
20.125
22.125
24.125
25.125
27.375
29.375
31.375
35.375
41.625
48.125
54.125
Fig. BP8222
Design Data
BP8222
Temperature Range
Range: +40F to +1200F
Higher temperatures available upon
request.
Insulation: Calcium Silicate asbestos
free, treated with water repellant.
Jackets: Galvanized Steel ASTM A-527.
Glue: Industrial contact adhesive.
Structural inserts: High-density
calcium silicate asbestos free, treated
with water repellant.
Steel Straps/Base: Carbon Steel
ASTM A-36.
Fasteners: ASTM A-307 plated.
Slide Pad: UHMW Polyethylene (Teflon
Optional).
Coating: Primer coated or hot dipped
galvanized. Other coatings available
upon request.
Note:
For higher load ratings, see BP8223
For lateral restraint, see BP8232
For lateral travel, see BP8252
Pipe
Size
1/2
3/4
1
1 1/2
2
2 1/2
3
4
5
6
8
10
12
14
16
18
20
24
30
36
42
Vert.
Load B
440
540
700
1030
1190
1460
1730
2690
3340
4090
5490
6460
7100
8070
9360
10330
10970
11620
15170
17750
20000
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
1" Thk.
C
E
1.5
1.5
2
2
2.5
2.5
3
4
4.5
5.5
7.5
9
10.5
11
12.5
14
15.5
18
22.5
26.5
31
3.25
3.25
4
4.5
5
5.5
6.187
7.25
8.5
9.5
11.625
13.875
16.125
17.125
19.375
21.375
23.375
27.375
33.625
40.125
46.125
1 1/2" Thk.
C
E
2" Thk.
C
E
4 2
4.375 4 2.5
4 2
4.375 4 2.5
4 2.5
5
4 3
4 2.5
5.5
4 4
4 3
6.1875 4 4
4 4
7.125 4 4.5
4 4
7.125 4 4.5
4 4.5
8.25 4 5.5
4 5.5
9.5
4 6.5
4 6.5
10.5 4 7.5
4 8
12.625 4 9
4 9.5 15.125 4 10.5
4 11 17.125 4 12
4 12 18.125 4 12.5
4 13 20.375 6 14
4 14.5 22.375 6 15.5
4 16 24.375 6 16.5
4 19 28.375 6 19.5
6 23 34.625 6 24
6 27.5 41.125 6 28
6 31.5 47.125 6 32.5
5.375
5.375
6.062
7.125
7.125
8.125
8.125
9.25
10.5
11.625
13.625
16.125
18.125
19.125
21.375
23.375
25.375
29.375
35.625
42.125
48.125
2 1/2" Thk.
C
E
4
4
4
4
4
4
4
4
4
4
6
6
6
6
6
6
6
6
6
6
6
4
4
4
4.5
4.5
5.5
5.5
6.5
7.5
8
9.5
11
12.5
13
14.5
16
17.5
20.5
24.5
28.5
33
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
7
7
7.125
8.125
8.125
9.125
9.125
10.25
11.625
12.625
14.875
17.125
19.125
20.125
22.375
24.375
26.375
30.375
36.625
43.125
49.125
3" Thk.
C
E
4.5
4.5
4.5
5.5
5.5
6.5
6.5
7.5
8
9
10.5
12
13
14
15.5
16.5
18
21
25
29.5
33.5
8
8
8.125
9.125
9.125
10.125
10.125
11.375
12.625
13.625
15.875
18.125
20.125
21.125
23.375
25.375
27.375
31.375
37.625
44.125
50.125
B
6
6
6
6
6
6
6
6
6
6
6
6
6
6
8
8
8
8
8
8
8
4" Thk.
C
E
6.5
6.5
6.5
7.5
7.5
8
8
9
9.5
10.5
12
13
14.5
15.5
16.5
18
19.5
22.5
26.5
31
35
10
10
10.125
11.25
11.25
12.25
12.375
13.375
14.875
15.875
18.125
20.125
22.125
23.125
25.375
27.375
29.375
33.375
39.625
46.125
52.125
B
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
5" Thk.
C
E
8
8
8
9
9
9.5
9.5
10.5
11
12
13
14.5
16
16.5
18
19.5
21
24
28
32.5
36.5
12.125
12.25
12.25
13.25
13.25
14.5
14.625
15.625
16.875
17.875
20.125
22.125
24.125
25.125
27.375
29.375
31.375
35.375
41.625
48.125
54.125
The load ratings represent average values obtained in accordance with accepted methods and are subject to normal manufacturing variations.
---- Dimensions and ratings are subject to change without notice. ----
Easy Installation
Order Information: Specify Quantity Pipe Size & Type Insulation Thickness Figure Number
Fig. BP8223
BP8223
Design Data
Temperature Range
Range: +40F to +1200F
Higher temperatures available upon
request.
Insulation: Calcium Silicate asbestos
free, treated with water repellant.
Jackets: Galvanized Steel ASTM A-527.
Glue: Industrial contact adhesive.
Structural inserts: High-density
calcium silicate asbestos free, treated
with water repellant.
Steel Straps/Base: Carbon Steel
ASTM A-36.
Fasteners: ASTM A-307 plated.
Slide Pad: UHMW Polyethylene (Teflon
Optional).
Coating: Primer coated or hot dipped
galvanized. Other coatings available
upon request.
Note:
For lateral restraint, see BP8233
For lateral travel, see BP8253
Pipe
Size
1/2
3/4
1
1 1/2
2
2 1/2
3
4
5
6
8
10
12
14
16
18
20
24
30
36
42
Vert.
Load B
600
760
970
1400
1620
1940
2260
3610
4520
5490
7320
8610
9470
10760
12480
13770
14630
15490
20220
23660
26670
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
1" Thk.
C
E
1.5
1.5
2
2
2.5
2.5
3
4
4.5
5.5
7.5
9
10.5
11
12.5
14
15.5
18
22.5
26.5
31
3.375
3.375
4
4.5
5
5.5
6.187
7.25
8.5
9.5
11.625
13.875
16.125
17.125
19.375
21.375
23.375
27.375
33.625
40.125
46.125
1 1/2" Thk.
C
E
2" Thk.
C
E
4 2
4.5
4 2.5
4 2
4.5
4 2.5
4 2.5
5
4 3
4 2.5
5.5
4 4
4 3
6.0625 4 4
4 4
7.125 4 4.5
4 4
7.125 4 4.5
4 4.5
8.25 4 5.5
4 5.5
9.5
4 6.5
4 6.5
10.5 4 7.5
4 8
12.625 4 9
4 9.5 15.125 4 10.5
4 11 17.125 4 12
4 12 18.125 4 12.5
4 13 20.375 6 14
4 14.5 22.375 6 15.5
4 16 24.375 6 16.5
4 19 28.375 6 19.5
6 23 34.625 6 24
6 27.5 41.125 6 28
6 31.5 47.125 6 32.5
5.5
5.5
6.062
7.125
7.125
8.125
8.125
9.25
10.5
11.625
13.625
16.125
18.125
19.125
21.375
23.375
25.375
29.375
35.625
42.125
48.125
2 1/2" Thk.
C
E
4
4
4
4
4
4
4
4
4
4
6
6
6
6
6
6
6
6
6
6
6
4
4
4
4.5
4.5
5.5
5.5
6.5
7.5
8
9.5
11
12.5
13
14.5
16
17.5
20.5
24.5
28.5
33
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
7.125
7.125
7.125
8.125
8.125
9.125
9.125
10.25
11.625
12.625
14.875
17.125
19.125
20.125
22.375
24.375
26.375
30.375
36.625
43.125
49.125
3" Thk.
C
E
4.5
4.5
4.5
5.5
5.5
6.5
6.5
7.5
8
9
10.5
12
13
14
15.5
16.5
18
21
25
29.5
33.5
8.125
8.125
8.125
9.125
9.125
10.125
10.125
11.375
12.625
13.625
15.875
18.125
20.125
21.125
23.375
25.375
27.375
31.375
37.625
44.125
50.125
B
6
6
6
6
6
6
6
6
6
6
6
6
6
6
8
8
8
8
8
8
8
4" Thk.
C
E
6.5
6.5
6.5
7.5
7.5
8
8
9
9.5
10.5
12
13
14.5
15.5
16.5
18
19.5
22.5
26.5
31
35
10.125
10.125
10.125
11.25
11.25
12.375
12.375
13.375
14.875
15.875
18.125
20.125
22.125
23.125
25.375
27.375
29.375
33.375
39.625
46.125
52.125
B
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
5" Thk.
C
E
8
8
8
9
9
9.5
9.5
10.5
11
12
13
14.5
16
16.5
18
19.5
21
24
28
32.5
36.5
The load ratings represent average values obtained in accordance with accepted methods and are subject to normal manufacturing variations.
---- Dimensions and ratings are subject to change without notice. ----
Easy Installation
Order Information: Specify Quantity Pipe Size & Type Insulation Thickness Figure Number
8
12.25
12.25
12.25
13.25
13.25
14.625
14.625
15.625
16.875
17.875
20.125
22.125
24.125
25.125
27.375
29.375
31.375
35.375
41.625
48.125
54.125
Fig. BP8230
Design Data
BP8230
Temperature Range
Range: +40F to +1200F
Higher temperatures available upon
request.
Insulation: Calcium Silicate asbestos
free, treated with water repellant.
Jackets: Galvanized Steel ASTM A-527.
Glue: Industrial contact adhesive.
Structural inserts: High-density
calcium silicate asbestos free, treated
with water repellant.
Steel Straps/Base: Carbon Steel
ASTM A-36
Fasteners: ASTM A-307 plated.
Slide Pad: UHMW Polyethylene (Teflon
Optional).
Coating: Primer coated or hot dipped.
galvanized. Other coatings available
upon request.
Note:
For higher load ratings, see BP8231
For greater axial travel, see BP8240
For lateral travel, see BP8250
Pipe
Size
1/2
3/4
1
1 1/2
2
2 1/2
3
4
5
6
8
10
12
14
16
18
20
24
30
36
42
Vert. Lat.
Load Load B
160
190
250
350
410
500
570
910
1130
1380
1830
2160
2370
2690
3120
3450
3660
3880
5060
5920
6670
32
38
50
70
82
100
114
182
226
276
366
432
474
538
624
690
732
776
1012
1184
1334
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
1" Thk.
C
E
6
6
6.5
6.5
7
7
7.5
8.5
10
11
13.5
15
17
17.5
20.5
22
23.5
26
32.5
36.5
41
3.25
3.25
3.875
4.375
5
5.5
6.062
7.25
8.25
9.25
11.625
13.625
16.125
17.125
19.125
21.375
23.375
27.375
33.625
39.625
46.125
1 1/2" Thk.
C
E
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
6
6
6
6.5
6.5
7
7
7.5
8.5
8.5
9
11
12
14
15.5
17.5
18.5
21
22.5
24
27
33
37.5
41.5
4
4
4
4
4
4
4
4
4
4
4
4
4
4
6
6
6
6
6
6
6
4.375
4.375
4.875
5.5
6.0625
7.125
7.125
8.25
9.25
10.25
12.625
14.875
17.125
18.125
20.125
22.375
24.375
28.375
34.625
41.125
47.125
2" Thk.
C
E
7
7
7.5
8.5
8.5
9
9
10
12
13
15
16.5
18.5
19
22
23.5
24.5
27.5
34
38
42.5
5.375
5.375
5.937
7
7
8.125
8.125
9.25
10.25
11.375
13.625
15.875
18.125
19.125
21.375
23.375
25.375
29.375
35.625
42.125
48.125
2 1/2" Thk.
C
E
4
4
4
4
4
4
4
4
4
4
6
6
6
6
6
6
6
6
6
6
6
8.5
8.5
8.5
9
9
10
10
11
13
13.5
15.5
17
19
19.5
22.5
24
25.5
28.5
34.5
38.5
43
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
7
7
7
8
8
9.125
9.125
10.25
11.375
12.625
14.875
16.875
19.125
20.125
22.375
24.375
26.375
30.375
36.625
43.125
49.125
3" Thk.
C
E
9
9
9
10
10
11
11
12
13.5
14.5
16.5
18
19.5
20.5
23.5
24.5
26
29
35
39.5
43.5
8
8
8
9
9.125
10.125
10.125
11.375
12.375
13.625
15.875
18.125
20.125
21.125
23.375
25.375
27.375
31.375
37.625
44.125
50.125
B
6
6
6
6
6
6
6
6
6
6
6
6
6
6
8
8
8
8
8
8
8
4" Thk.
C
E
11
11
11
12
12
12.5
12.5
13.5
15
16
18
19
21
22
24.5
26
27.5
30.5
36.5
41
45
10
10
10
11.25
11.25
12.25
12.375
13.375
14.875
15.875
17.875
20.125
22.125
23.125
25.375
27.375
29.375
33.375
39.625
46.125
52.125
B
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
5" Thk.
C
E
12.5
12.5
12.5
13.5
13.5
14
14
15
16.5
17.5
19
20.5
22.5
23
26
27.5
29
32
38
42.5
46.5
12.125
12.125
12.25
13.25
13.25
14.5
14.625
15.625
16.875
17.875
20.125
22.125
24.125
25.125
27.375
29.375
31.375
35.375
41.625
48.125
54.125
The load ratings represent average values obtained in accordance with accepted methods and are subject to normal manufacturing variations.
---- Dimensions and ratings are subject to change without notice. ----
Easy Installation
Order Information: Specify Quantity Pipe Size & Type Insulation Thickness Figure Number
Fig. BP8231
BP8231
Design Data
Temperature Range
Range: +40F to +1200F
Higher temperatures available upon
request.
Insulation: Calcium Silicate asbestos
free, treated with water repellant.
Jackets: Galvanized Steel ASTM A-527.
Glue: Industrial contact adhesive.
Structural inserts: High-density
calcium silicate asbestos free, treated
with water repellant.
Steel Straps/Base: Carbon Steel
ASTM A-36
Fasteners: ASTM A-307 plated.
Slide Pad: UHMW Polyethylene (Teflon
Optional).
Coating: Primer coated or hot dipped.
galvanized. Other coatings available
upon request.
Note:
For higher load ratings, see BP8232
For greater axial travel, see BP8241
For lateral travel, see BP8251
Pipe
Size
1/2
3/4
1
1 1/2
2
2 1/2
3
4
5
6
8
10
12
14
16
18
20
24
30
36
42
Vert. Lat.
Load Load B
310
380
490
700
810
990
1140
1810
2260
2750
3660
4310
4740
5380
6240
6890
7320
7750
10110
11830
13340
62
76
98
140
162
198
228
362
452
550
732
862
948
1076
1248
1378
1464
1550
2022
2366
2668
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
1" Thk.
C
E
6
6
6.5
6.5
7
7
7.5
8.5
10
11
13.5
15
17
17.5
20.5
22
23.5
26
32.5
36.5
41
3.25
3.25
3.875
4.5
5
5.5
6.187
7.25
8.5
9.5
11.625
13.875
16.125
17.125
19.375
21.375
23.375
27.375
33.625
40.125
46.125
1 1/2" Thk.
C
E
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
6
6
6
6.5
6.5
7
7
7.5
8.5
8.5
9
11
12
14
15.5
17.5
18.5
21
22.5
24
27
33
37.5
41.5
4
4
4
4
4
4
4
4
4
4
4
4
4
4
6
6
6
6
6
6
6
4.375
4.375
5
5.5
6.0625
7.125
7.125
8.25
9.5
10.5
12.625
15.125
17.125
18.125
20.375
22.375
24.375
28.375
34.625
41.125
47.125
2" Thk.
C
E
7
7
7.5
8.5
8.5
9
9
10
12
13
15
16.5
18.5
19
22
23.5
24.5
27.5
34
38
42.5
5.375
5.375
6.062
7.125
7.125
8.125
8.125
9.25
10.5
11.625
13.625
16.125
18.125
19.125
21.375
23.375
25.375
29.375
35.625
42.125
48.125
2 1/2" Thk.
C
E
4
4
4
4
4
4
4
4
4
4
6
6
6
6
6
6
6
6
6
6
6
8.5
8.5
8.5
9
9
10
10
11
13
13.5
15.5
17
19
19.5
22.5
24
25.5
28.5
34.5
38.5
43
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
7
7
7
8.125
8.125
9.125
9.125
10.25
11.625
12.625
14.875
17.125
19.125
20.125
22.375
24.375
26.375
30.375
36.625
43.125
49.125
3" Thk.
C
E
9
9
9
10
10
11
11
12
13.5
14.5
16.5
18
19.5
20.5
23.5
24.5
26
29
35
39.5
43.5
8
8
8
9.125
9.125
10.125
10.125
11.375
12.625
13.625
15.875
18.125
20.125
21.125
23.375
25.375
27.375
31.375
37.625
44.125
50.125
B
6
6
6
6
6
6
6
6
6
6
6
6
6
6
8
8
8
8
8
8
8
4" Thk.
C
E
11
11
11
12
12
12.5
12.5
13.5
15
16
18
19
21
22
24.5
26
27.5
30.5
36.5
41
45
10
10
10
11.25
11.25
12.25
12.375
13.375
14.875
15.875
18.125
20.125
22.125
23.125
25.375
27.375
29.375
33.375
39.625
46.125
52.125
5" Thk.
C
E
B
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
12.5
12.5
12.5
13.5
13.5
14
14
15
16.5
17.5
19
20.5
22.5
23
26
27.5
29
32
38
42.5
46.5
The load ratings represent average values obtained in accordance with accepted methods and are subject to normal manufacturing variations.
---- Dimensions and ratings are subject to change without notice. ----
Easy Installation
Order Information: Specify Quantity Pipe Size & Type Insulation Thickness Figure Number
10
12.125
12.25
12.25
13.25
13.25
14.5
14.625
15.625
16.875
17.875
20.125
22.125
24.125
25.125
27.375
29.375
31.375
35.375
41.625
48.125
54.125
Fig. BP8232
Design Data
BP8232
Temperature Range
Range: +40F to +1200F
Higher temperatures available upon
request.
Insulation: Calcium Silicate asbestos
free, treated with water repellant.
Jackets: Galvanized Steel ASTM A-527.
Glue: Industrial contact adhesive.
Structural inserts: High-density
calcium silicate asbestos free, treated
with water repellant.
Steel Straps/Base: Carbon Steel
ASTM A-36.
Fasteners: ASTM A-307 plated.
Slide Pad: UHMW Polyethylene (Teflon
Optional).
Coating: Primer coated or hot dipped
galvanized. Other coatings available
upon request.
Note:
For higher load ratings, see BP8233
For greater axial travel, see BP8242
For lateral travel, see BP8252
Pipe
Size
1/2
3/4
1
1 1/2
2
2 1/2
3
4
5
6
8
10
12
14
16
18
20
24
30
36
42
Vert. Lat.
Load Load B
440
540
700
1030
1190
1460
1730
2690
3340
4090
5490
6460
7100
8070
9360
10330
10970
11620
15170
17750
20000
88
108
140
206
238
292
346
538
668
818
1098
1292
1420
1614
1872
2066
2194
2324
3034
3550
4000
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
1" Thk.
C
E
6
6
6.5
6.5
7
7
7.5
8.5
10
11
13.5
15
17
17.5
20.5
22
23.5
26
32.5
36.5
41
3.25
3.25
4
4.5
5
5.5
6.187
7.25
8.5
9.5
11.625
13.875
16.125
17.125
19.375
21.375
23.375
27.375
33.625
40.125
46.125
1 1/2" Thk.
C
E
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
6
6
6
6.5
6.5
7
7
7.5
8.5
8.5
9
11
12
14
15.5
17.5
18.5
21
22.5
24
27
33
37.5
41.5
4
4
4
4
4
4
4
4
4
4
4
4
4
4
6
6
6
6
6
6
6
4.375
4.375
5
5.5
6.1875
7.125
7.125
8.25
9.5
10.5
12.625
15.125
17.125
18.125
20.375
22.375
24.375
28.375
34.625
41.125
47.125
2" Thk.
C
E
7
7
7.5
8.5
8.5
9
9
10
12
13
15
16.5
18.5
19
22
23.5
24.5
27.5
34
38
42.5
5.375
5.375
6.062
7.125
7.125
8.125
8.125
9.25
10.5
11.625
13.625
16.125
18.125
19.125
21.375
23.375
25.375
29.375
35.625
42.125
48.125
2 1/2" Thk.
C
E
4
4
4
4
4
4
4
4
4
4
6
6
6
6
6
6
6
6
6
6
6
8.5
8.5
8.5
9
9
10
10
11
13
13.5
15.5
17
19
19.5
22.5
24
25.5
28.5
34.5
38.5
43
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
7
7
7.125
8.125
8.125
9.125
9.125
10.25
11.625
12.625
14.875
17.125
19.125
20.125
22.375
24.375
26.375
30.375
36.625
43.125
49.125
3" Thk.
C
E
9
9
9
10
10
11
11
12
13.5
14.5
16.5
18
19.5
20.5
23.5
24.5
26
29
35
39.5
43.5
8
8
8.125
9.125
9.125
10.125
10.125
11.375
12.625
13.625
15.875
18.125
20.125
21.125
23.375
25.375
27.375
31.375
37.625
44.125
50.125
B
6
6
6
6
6
6
6
6
6
6
6
6
6
6
8
8
8
8
8
8
8
4" Thk.
C
E
11
11
11
12
12
12.5
12.5
13.5
15
16
18
19
21
22
24.5
26
27.5
30.5
36.5
41
45
10
10
10.125
11.25
11.25
12.25
12.375
13.375
14.875
15.875
18.125
20.125
22.125
23.125
25.375
27.375
29.375
33.375
39.625
46.125
52.125
B
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
5" Thk.
C
E
12.5
12.5
12.5
13.5
13.5
14
14
15
16.5
17.5
19
20.5
22.5
23
26
27.5
29
32
38
42.5
46.5
12.125
12.25
12.25
13.25
13.25
14.5
14.625
15.625
16.875
17.875
20.125
22.125
24.125
25.125
27.375
29.375
31.375
35.375
41.625
48.125
54.125
The load ratings represent average values obtained in accordance with accepted methods and are subject to normal manufacturing variations.
---- Dimensions and ratings are subject to change without notice. ----
Easy Installation
Order Information: Specify Quantity Pipe Size & Type Insulation Thickness Figure Number
11
Fig. BP8233
BP8233
Design Data
Temperature Range
Range: +40F to +1200F
Higher temperatures available upon
request.
Insulation: Calcium Silicate asbestos
free, treated with water repellant.
Jackets: Galvanized Steel ASTM A-527.
Glue: Industrial contact adhesive.
Structural inserts: High-density
calcium silicate asbestos free, treated
with water repellant.
Steel Straps/Base: Carbon Steel
ASTM A-36.
Fasteners: ASTM A-307 plated.
Slide Pad: UHMW Polyethylene (Teflon
Optional).
Coating: Primer coated or hot dipped
galvanized. Other coatings available
upon request.
Note:
For greater axial travel, see BP8243
For lateral travel, see BP8253
Pipe
Size
1/2
3/4
1
1 1/2
2
2 1/2
3
4
5
6
8
10
12
14
16
18
20
24
30
36
42
Vert. Lat.
Load Load B
600
760
970
1400
1620
1940
2260
3610
4520
5490
7320
8610
9470
10760
12480
13770
14630
15490
20220
23660
26670
120
152
194
280
324
388
452
722
904
1098
1464
1722
1894
2152
2496
2754
2926
3098
4044
4732
5334
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
1" Thk.
C
E
6
6
6.5
6.5
7
7
7.5
8.5
10
11
13.5
15
17
17.5
20.5
22
23.5
26
32.5
36.5
41
3.375
3.375
4
4.5
5
5.5
6.187
7.25
8.5
9.5
11.625
13.875
16.125
17.125
19.375
21.375
23.375
27.375
33.625
40.125
46.125
1 1/2" Thk.
C
E
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
6
6
6
6.5
6.5
7
7
7.5
8.5
8.5
9
11
12
14
15.5
17.5
18.5
21
22.5
24
27
33
37.5
41.5
4
4
4
4
4
4
4
4
4
4
4
4
4
4
6
6
6
6
6
6
6
4.5
4.5
5
5.5
6.0625
7.125
7.125
8.25
9.5
10.5
12.625
15.125
17.125
18.125
20.375
22.375
24.375
28.375
34.625
41.125
47.125
2" Thk.
C
E
7
7
7.5
8.5
8.5
9
9
10
12
13
15
16.5
18.5
19
22
23.5
24.5
27.5
34
38
42.5
5.5
5.5
6.062
7.125
7.125
8.125
8.125
9.25
10.5
11.625
13.625
16.125
18.125
19.125
21.375
23.375
25.375
29.375
35.625
42.125
48.125
2 1/2" Thk.
C
E
4
4
4
4
4
4
4
4
4
4
6
6
6
6
6
6
6
6
6
6
6
8.5
8.5
8.5
9
9
10
10
11
13
13.5
15.5
17
19
19.5
22.5
24
25.5
28.5
34.5
38.5
43
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
7.125
7.125
7.125
8.125
8.125
9.125
9.125
10.25
11.625
12.625
14.875
17.125
19.125
20.125
22.375
24.375
26.375
30.375
36.625
43.125
49.125
3" Thk.
C
E
9
9
9
10
10
11
11
12
13.5
14.5
16.5
18
19.5
20.5
23.5
24.5
26
29
35
39.5
43.5
8.125
8.125
8.125
9.125
9.125
10.125
10.125
11.375
12.625
13.625
15.875
18.125
20.125
21.125
23.375
25.375
27.375
31.375
37.625
44.125
50.125
B
6
6
6
6
6
6
6
6
6
6
6
6
6
6
8
8
8
8
8
8
8
4" Thk.
C
E
11
11
11
12
12
12.5
12.5
13.5
15
16
18
19
21
22
24.5
26
27.5
30.5
36.5
41
45
10.125
10.125
10.125
11.25
11.25
12.375
12.375
13.375
14.875
15.875
18.125
20.125
22.125
23.125
25.375
27.375
29.375
33.375
39.625
46.125
52.125
5" Thk.
C
E
B
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
12.5
12.5
12.5
13.5
13.5
14
14
15
16.5
17.5
19
20.5
22.5
23
26
27.5
29
32
38
42.5
46.5
The load ratings represent average values obtained in accordance with accepted methods and are subject to normal manufacturing variations.
---- Dimensions and ratings are subject to change without notice. ----
Easy Installation
Order Information: Specify Quantity Pipe Size & Type Insulation Thickness Figure Number
12
12.25
12.25
12.25
13.25
13.25
14.625
14.625
15.625
16.875
17.875
20.125
22.125
24.125
25.125
27.375
29.375
31.375
35.375
41.625
48.125
54.125
Fig. BP8240
Design Data
BP8240
Temperature Range
Range: +40F to +1200F
Higher temperatures available upon
request.
Insulation: Calcium Silicate asbestos
free, treated with water repellant.
Jackets: Galvanized Steel ASTM A-527.
Glue: Industrial contact adhesive.
Structural inserts: High-density
calcium silicate asbestos free, treated
with water repellant.
Steel Straps/Base: Carbon Steel
ASTM A-36.
Fasteners: ASTM A-307 plated.
Slide Pad: UHMW Polyethylene (Teflon
Optional).
Coating: Primer coated or hot dipped
galvanized. Other coatings available
upon request.
Note:
For higher load ratings, see BP8241
For lateral travel, see BP8250
Pipe
Size
1/2
3/4
1
1 1/2
2
2 1/2
3
4
5
6
8
10
12
14
16
18
20
24
30
36
42
Vert. Lat.
Load Load B
160
190
250
350
410
500
570
910
1130
1380
1830
2160
2370
2690
3120
3450
3660
3880
5060
5920
6670
32
38
50
70
82
100
114
182
226
276
366
432
474
538
624
690
732
776
1012
1184
1334
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
1" Thk.
C
E
6
6
6.5
6.5
7
7
7.5
8.5
10
11
13.5
15
17
17.5
20.5
22
23.5
26
32.5
36.5
41
3.25
3.25
3.875
4.375
5
5.5
6.062
7.25
8.25
9.25
11.625
13.625
16.125
17.125
19.125
21.375
23.375
27.375
33.625
39.625
46.125
1 1/2" Thk.
C
E
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
6
6
6
6.5
6.5
7
7
7.5
8.5
8.5
9
11
12
14
15.5
17.5
18.5
21
22.5
24
27
33
37.5
41.5
4
4
4
4
4
4
4
4
4
4
4
4
4
4
6
6
6
6
6
6
6
4.375
4.375
4.875
5.5
6.0625
7.125
7.125
8.25
9.25
10.25
12.625
14.875
17.125
18.125
20.125
22.375
24.375
28.375
34.625
41.125
47.125
2" Thk.
C
E
7
7
7.5
8.5
8.5
9
9
10
12
13
15
16.5
18.5
19
22
23.5
24.5
27.5
34
38
42.5
5.375
5.375
5.937
7
7
8.125
8.125
9.25
10.25
11.375
13.625
15.875
18.125
19.125
21.375
23.375
25.375
29.375
35.625
42.125
48.125
2 1/2" Thk.
C
E
4
4
4
4
4
4
4
4
4
4
6
6
6
6
6
6
6
6
6
6
6
8.5
8.5
8.5
9
9
10
10
11
13
13.5
15.5
17
19
19.5
22.5
24
25.5
28.5
34.5
38.5
43
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
7
7
7
8
8
9.125
9.125
10.25
11.375
12.625
14.875
16.875
19.125
20.125
22.375
24.375
26.375
30.375
36.625
43.125
49.125
3" Thk.
C
E
9
9
9
10
10
11
11
12
13.5
14.5
16.5
18
19.5
20.5
23.5
24.5
26
29
35
39.5
43.5
8
8
8
9
9.125
10.125
10.125
11.375
12.375
13.625
15.875
18.125
20.125
21.125
23.375
25.375
27.375
31.375
37.625
44.125
50.125
B
6
6
6
6
6
6
6
6
6
6
6
6
6
6
8
8
8
8
8
8
8
4" Thk.
C
E
11
11
11
12
12
12.5
12.5
13.5
15
16
18
19
21
22
24.5
26
27.5
30.5
36.5
41
45
10
10
10
11.25
11.25
12.25
12.375
13.375
14.875
15.875
17.875
20.125
22.125
23.125
25.375
27.375
29.375
33.375
39.625
46.125
52.125
B
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
5" Thk.
C
E
12.5
12.5
12.5
13.5
13.5
14
14
15
16.5
17.5
19
20.5
22.5
23
26
27.5
29
32
38
42.5
46.5
12.125
12.125
12.25
13.25
13.25
14.5
14.625
15.625
16.875
17.875
20.125
22.125
24.125
25.125
27.375
29.375
31.375
35.375
41.625
48.125
54.125
The load ratings represent average values obtained in accordance with accepted methods and are subject to normal manufacturing variations.
---- Dimensions and ratings are subject to change without notice. ----
Easy Installation
Order Information: Specify Quantity Pipe Size & Type Insulation Thickness Figure Number
13
Fig. BP8241
BP8241
Design Data
Temperature Range
Range: +40F to +1200F
Higher temperatures available upon
request.
Insulation: Calcium Silicate asbestos
free, treated with water repellant.
Jackets: Galvanized Steel ASTM A-527.
Glue: Industrial contact adhesive.
Structural inserts: High-density
calcium silicate asbestos free, treated
with water repellant.
Steel Straps/Base: Carbon Steel
ASTM A-36.
Fasteners: ASTM A-307 plated.
Slide Pad: UHMW Polyethylene (Teflon
Optional).
Coating: Primer coated or hot dipped
galvanized. Other coatings available
upon request.
Note:
For higher load ratings, see BP8242
For lateral travel, see BP8251
Pipe
Size
1/2
3/4
1
1 1/2
2
2 1/2
3
4
5
6
8
10
12
14
16
18
20
24
30
36
42
Vert. Lat.
Load Load B
310
380
490
700
810
990
1140
1810
2260
2750
3660
4310
4740
5380
6240
6890
7320
7750
10110
11830
13340
62
76
98
140
162
198
228
362
452
550
732
862
948
1076
1248
1378
1464
1550
2022
2366
2668
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
1" Thk.
C
E
6
6
6.5
6.5
7
7
7.5
8.5
10
11
13.5
15
17
17.5
20.5
22
23.5
26
32.5
36.5
41
3.25
3.25
3.875
4.5
5
5.5
6.187
7.25
8.5
9.5
11.625
13.875
16.125
17.125
19.375
21.375
23.375
27.375
33.625
40.125
46.125
1 1/2" Thk.
C
E
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
6
6
6
6.5
6.5
7
7
7.5
8.5
8.5
9
11
12
14
15.5
17.5
18.5
21
22.5
24
27
33
37.5
41.5
4
4
4
4
4
4
4
4
4
4
4
4
4
4
6
6
6
6
6
6
6
4.375
4.375
5
5.5
6.0625
7.125
7.125
8.25
9.5
10.5
12.625
15.125
17.125
18.125
20.375
22.375
24.375
28.375
34.625
41.125
47.125
2" Thk.
C
E
7
7
7.5
8.5
8.5
9
9
10
12
13
15
16.5
18.5
19
22
23.5
24.5
27.5
34
38
42.5
5.375
5.375
6.062
7.125
7.125
8.125
8.125
9.25
10.5
11.625
13.625
16.125
18.125
19.125
21.375
23.375
25.375
29.375
35.625
42.125
48.125
2 1/2" Thk.
C
E
4
4
4
4
4
4
4
4
4
4
6
6
6
6
6
6
6
6
6
6
6
8.5
8.5
8.5
9
9
10
10
11
13
13.5
15.5
17
19
19.5
22.5
24
25.5
28.5
34.5
38.5
43
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
7
7
7
8.125
8.125
9.125
9.125
10.25
11.625
12.625
14.875
17.125
19.125
20.125
22.375
24.375
26.375
30.375
36.625
43.125
49.125
3" Thk.
C
E
9
9
9
10
10
11
11
12
13.5
14.5
16.5
18
19.5
20.5
23.5
24.5
26
29
35
39.5
43.5
8
8
8
9.125
9.125
10.125
10.125
11.375
12.625
13.625
15.875
18.125
20.125
21.125
23.375
25.375
27.375
31.375
37.625
44.125
50.125
B
6
6
6
6
6
6
6
6
6
6
6
6
6
6
8
8
8
8
8
8
8
4" Thk.
C
E
11
11
11
12
12
12.5
12.5
13.5
15
16
18
19
21
22
24.5
26
27.5
30.5
36.5
41
45
10
10
10
11.25
11.25
12.25
12.375
13.375
14.875
15.875
18.125
20.125
22.125
23.125
25.375
27.375
29.375
33.375
39.625
46.125
52.125
5" Thk.
C
E
B
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
12.5
12.5
12.5
13.5
13.5
14
14
15
16.5
17.5
19
20.5
22.5
23
26
27.5
29
32
38
42.5
46.5
The load ratings represent average values obtained in accordance with accepted methods and are subject to normal manufacturing variations.
---- Dimensions and ratings are subject to change without notice. ----
Easy Installation
Order Information: Specify Quantity Pipe Size & Type Insulation Thickness Figure Number
14
12.125
12.25
12.25
13.25
13.25
14.5
14.625
15.625
16.875
17.875
20.125
22.125
24.125
25.125
27.375
29.375
31.375
35.375
41.625
48.125
54.125
Fig. BP8242
Design Data
BP8242
Temperature Range
Range: +40F to +1200F
Higher temperatures available upon
request.
Insulation: Calcium Silicate asbestos
free, treated with water repellant.
Jackets: Galvanized Steel ASTM A-527.
Glue: Industrial contact adhesive.
Structural inserts: High-density
calcium silicate asbestos free, treated
with water repellant.
Steel Straps/Base: Carbon Steel
ASTM A-36.
Fasteners: ASTM A-307 plated.
Slide Pad: UHMW Polyethylene (Teflon
Optional).
Coating: Primer coated or hot dipped
galvanized. Other coatings available
upon request.
Note:
For higher load ratings, see BP8243
For lateral travel, see BP8252
Pipe
Size
1/2
3/4
1
1 1/2
2
2 1/2
3
4
5
6
8
10
12
14
16
18
20
24
30
36
42
Vert. Lat.
Load Load B
440
540
700
1030
1190
1460
1730
2690
3340
4090
5490
6460
7100
8070
9360
10330
10970
11620
15170
17750
20000
88
108
140
206
238
292
346
538
668
818
1098
1292
1420
1614
1872
2066
2194
2324
3034
3550
4000
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
1" Thk.
C
E
6
6
6.5
6.5
7
7
7.5
8.5
10
11
13.5
15
17
17.5
20.5
22
23.5
26
32.5
36.5
41
3.25
3.25
4
4.5
5
5.5
6.187
7.25
8.5
9.5
11.625
13.875
16.125
17.125
19.375
21.375
23.375
27.375
33.625
40.125
46.125
1 1/2" Thk.
C
E
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
6
6
6
6.5
6.5
7
7
7.5
8.5
8.5
9
11
12
14
15.5
17.5
18.5
21
22.5
24
27
33
37.5
41.5
4
4
4
4
4
4
4
4
4
4
4
4
4
4
6
6
6
6
6
6
6
4.375
4.375
5
5.5
6.1875
7.125
7.125
8.25
9.5
10.5
12.625
15.125
17.125
18.125
20.375
22.375
24.375
28.375
34.625
41.125
47.125
2" Thk.
C
E
7
7
7.5
8.5
8.5
9
9
10
12
13
15
16.5
18.5
19
22
23.5
24.5
27.5
34
38
42.5
5.375
5.375
6.062
7.125
7.125
8.125
8.125
9.25
10.5
11.625
13.625
16.125
18.125
19.125
21.375
23.375
25.375
29.375
35.625
42.125
48.125
2 1/2" Thk.
C
E
4
4
4
4
4
4
4
4
4
4
6
6
6
6
6
6
6
6
6
6
6
8.5
8.5
8.5
9
9
10
10
11
13
13.5
15.5
17
19
19.5
22.5
24
25.5
28.5
34.5
38.5
43
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
7
7
7.125
8.125
8.125
9.125
9.125
10.25
11.625
12.625
14.875
17.125
19.125
20.125
22.375
24.375
26.375
30.375
36.625
43.125
49.125
3" Thk.
C
E
9
9
9
10
10
11
11
12
13.5
14.5
16.5
18
19.5
20.5
23.5
24.5
26
29
35
39.5
43.5
8
8
8.125
9.125
9.125
10.125
10.125
11.375
12.625
13.625
15.875
18.125
20.125
21.125
23.375
25.375
27.375
31.375
37.625
44.125
50.125
B
6
6
6
6
6
6
6
6
6
6
6
6
6
6
8
8
8
8
8
8
8
4" Thk.
C
E
11
11
11
12
12
12.5
12.5
13.5
15
16
18
19
21
22
24.5
26
27.5
30.5
36.5
41
45
10
10
10.125
11.25
11.25
12.25
12.375
13.375
14.875
15.875
18.125
20.125
22.125
23.125
25.375
27.375
29.375
33.375
39.625
46.125
52.125
B
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
5" Thk.
C
E
12.5
12.5
12.5
13.5
13.5
14
14
15
16.5
17.5
19
20.5
22.5
23
26
27.5
29
32
38
42.5
46.5
12.125
12.25
12.25
13.25
13.25
14.5
14.625
15.625
16.875
17.875
20.125
22.125
24.125
25.125
27.375
29.375
31.375
35.375
41.625
48.125
54.125
The load ratings represent average values obtained in accordance with accepted methods and are subject to normal manufacturing variations.
---- Dimensions and ratings are subject to change without notice. ----
Easy Installation
Order Information: Specify Quantity Pipe Size & Type Insulation Thickness Figure Number
15
Fig. BP8243
BP8243
Design Data
Temperature Range
Range: +40F to +1200F
Higher temperatures available upon
request.
Insulation: Calcium Silicate asbestos
free, treated with water repellant.
Jackets: Galvanized Steel ASTM A-527.
Glue: Industrial contact adhesive.
Structural inserts: High-density
calcium silicate asbestos free, treated
with water repellant.
Steel Straps/Base: Carbon Steel
ASTM A-36.
Fasteners: ASTM A-307 plated.
Slide Pad: UHMW Polyethylene (Teflon
Optional).
Coating: Primer coated or hot dipped
galvanized. Other coatings available
upon request.
Note:
For lateral travel, see BP8253
Pipe
Size
1/2
3/4
1
1 1/2
2
2 1/2
3
4
5
6
8
10
12
14
16
18
20
24
30
36
42
Vert. Lat.
Load Load B
600
760
970
1400
1620
1940
2260
3610
4520
5490
7320
8610
9470
10760
12480
13770
14630
15490
20220
23660
26670
120
152
194
280
324
388
452
722
904
1098
1464
1722
1894
2152
2496
2754
2926
3098
4044
4732
5334
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
1" Thk.
C
E
6
6
6.5
6.5
7
7
7.5
8.5
10
11
13.5
15
17
17.5
20.5
22
23.5
26
32.5
36.5
41
3.375
3.375
4
4.5
5
5.5
6.187
7.25
8.5
9.5
11.625
13.875
16.125
17.125
19.375
21.375
23.375
27.375
33.625
40.125
46.125
1 1/2" Thk.
C
E
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
6
6
6
6.5
6.5
7
7
7.5
8.5
8.5
9
11
12
14
15.5
17.5
18.5
21
22.5
24
27
33
37.5
41.5
4
4
4
4
4
4
4
4
4
4
4
4
4
4
6
6
6
6
6
6
6
4.5
4.5
5
5.5
6.0625
7.125
7.125
8.25
9.5
10.5
12.625
15.125
17.125
18.125
20.375
22.375
24.375
28.375
34.625
41.125
47.125
2" Thk.
C
E
7
7
7.5
8.5
8.5
9
9
10
12
13
15
16.5
18.5
19
22
23.5
24.5
27.5
34
38
42.5
5.5
5.5
6.062
7.125
7.125
8.125
8.125
9.25
10.5
11.625
13.625
16.125
18.125
19.125
21.375
23.375
25.375
29.375
35.625
42.125
48.125
2 1/2" Thk.
C
E
4
4
4
4
4
4
4
4
4
4
6
6
6
6
6
6
6
6
6
6
6
8.5
8.5
8.5
9
9
10
10
11
13
13.5
15.5
17
19
19.5
22.5
24
25.5
28.5
34.5
38.5
43
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
7.125
7.125
7.125
8.125
8.125
9.125
9.125
10.25
11.625
12.625
14.875
17.125
19.125
20.125
22.375
24.375
26.375
30.375
36.625
43.125
49.125
3" Thk.
C
E
9
9
9
10
10
11
11
12
13.5
14.5
16.5
18
19.5
20.5
23.5
24.5
26
29
35
39.5
43.5
8.125
8.125
8.125
9.125
9.125
10.125
10.125
11.375
12.625
13.625
15.875
18.125
20.125
21.125
23.375
25.375
27.375
31.375
37.625
44.125
50.125
B
6
6
6
6
6
6
6
6
6
6
6
6
6
6
8
8
8
8
8
8
8
4" Thk.
C
E
11
11
11
12
12
12.5
12.5
13.5
15
16
18
19
21
22
24.5
26
27.5
30.5
36.5
41
45
10.125
10.125
10.125
11.25
11.25
12.375
12.375
13.375
14.875
15.875
18.125
20.125
22.125
23.125
25.375
27.375
29.375
33.375
39.625
46.125
52.125
5" Thk.
C
E
B
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
12.5
12.5
12.5
13.5
13.5
14
14
15
16.5
17.5
19
20.5
22.5
23
26
27.5
29
32
38
42.5
46.5
The load ratings represent average values obtained in accordance with accepted methods and are subject to normal manufacturing variations.
---- Dimensions and ratings are subject to change without notice. ----
Easy Installation
Order Information: Specify Quantity Pipe Size & Type Insulation Thickness Figure Number
16
12.25
12.25
12.25
13.25
13.25
14.625
14.625
15.625
16.875
17.875
20.125
22.125
24.125
25.125
27.375
29.375
31.375
35.375
41.625
48.125
54.125
Fig. BP8250
Design Data
BP8250
Temperature Range
Range: +40F to +1200F
Higher temperatures available upon
request.
Insulation: Calcium Silicate asbestos
free, treated with water repellant.
Jackets: Galvanized Steel ASTM A-527.
Glue: Industrial contact adhesive.
Structural inserts: High-density
calcium silicate asbestos free, treated
with water repellant.
Steel Straps/Base: Carbon Steel
ASTM A-36.
Fasteners: ASTM A-307 plated.
Slide Pad: UHMW Polyethylene (Teflon
Optional).
Coating: Primer coated or hot dipped
galvanized. Other coatings available
upon request.
Note:
For higher load ratings, see BP8251
For greater axial travel, see BP8260
For lateral restraint, see BP8230
Pipe Vert.
Size Load
1" Thk.
L = +/- 1-1/2
B C
E
1 1/2" Thk.
L = +/- 1-3/4
B C
E
1/2
3/4
1
1 1/2
2
2 1/2
3
4
5
6
8
10
12
14
16
18
20
24
30
36
42
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
6
6
6
4 7.25
4 7.25
4 7.75
4 8.75
4 8.75
4 9.75
4 9.75
4 10.25
4 11
4 11.5
4 12.5
4 13.5
4 14.5
4 15
6 16
6 17
6 18
6 20
6 25
6 29
6 33.5
160
190
250
350
410
500
570
910
1130
1380
1830
2160
2370
2690
3120
3450
3660
3880
5060
5920
6670
5.25
5.25
5.75
6.25
6.75
7.25
7.75
8.25
9
9.5
10.5
11.5
12.5
13
14
15
16
18.5
23.5
27.5
32
3.25
3.25
3.875
4.375
5
5.5
6.062
7.25
8.25
9.25
11.625
13.625
16.125
17.125
19.125
21.375
23.375
27.375
33.625
39.625
46.125
6.25
6.25
6.75
7.25
7.75
8.75
8.75
9.25
10
10.5
11.5
12.5
13.5
14
15
16
17
19.5
24
28.5
32.5
4.375
4.375
4.875
5.5
6.0625
7.125
7.125
8.25
9.25
10.25
12.625
14.875
17.125
18.125
20.125
22.375
24.375
28.375
34.625
41.125
47.125
2" Thk.
L = +/- 2
C
E
5.375
5.375
5.937
7
7
8.125
8.125
9.25
10.25
11.375
13.625
15.875
18.125
19.125
21.375
23.375
25.375
29.375
35.625
42.125
48.125
2 1/2" Thk.
L = +/- 2-1/4
B C
E
3" Thk.
L = +/- 2-1/2
B C
E
4 8.75
4 8.75
4 8.75
4 9.75
4 9.75
4 10.75
4 10.75
4 11.25
4 12
4 12.5
6 13.5
6 14.5
6 15.5
6 16
6 17
6 18
6 19
6 21
6 25.5
6 29.5
6 34
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
8
8
8
8
8
8
8
7
7
7
8
8
9.125
9.125
10.25
11.375
12.625
14.875
16.875
19.125
20.125
22.375
24.375
26.375
30.375
36.625
43.125
49.125
9.75
9.75
9.75
10.75
10.75
11.75
11.75
12.25
13
13.5
14.5
15.5
16.5
17
18
19
20
22
26
30.5
34.5
8
8
8
9
9.125
10.125
10.125
11.375
12.375
13.625
15.875
18.125
20.125
21.125
23.375
25.375
27.375
31.375
37.625
44.125
50.125
4" Thk.
L = +/- 3
C
E
11.75
11.75
11.75
12.75
12.75
13.75
13.75
14.25
15
15.5
16.5
17.5
18.5
19
20
21
22
24
27.5
32
36
10
10
10
11.25
11.25
12.25
12.375
13.375
14.875
15.875
17.875
20.125
22.125
23.125
25.375
27.375
29.375
33.375
39.625
46.125
52.125
5" Thk.
L = +/- 3-1/2
B C
E
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
13.75
13.75
13.75
14.75
14.75
15.75
15.75
16.25
17
17.5
18.5
19.5
20.5
21
22
23
24
26
29
33.5
37.5
12.125
12.125
12.25
13.25
13.25
14.5
14.625
15.625
16.875
17.875
20.125
22.125
24.125
25.125
27.375
29.375
31.375
35.375
41.625
48.125
54.125
The load ratings represent average values obtained in accordance with accepted methods and are subject to normal manufacturing variations.
---- Dimensions and ratings are subject to change without notice. ----
Easy Installation
Order Information: Specify Quantity Pipe Size & Type Insulation Thickness Figure Number
17
Fig. BP8251
BP8251
Design Data
Temperature Range
Range: +40F to +1200F
Higher temperatures available upon
request.
Insulation: Calcium Silicate asbestos
free, treated with water repellant.
Jackets: Galvanized Steel ASTM A-527.
Glue: Industrial contact adhesive.
Structural inserts: High-density
calcium silicate asbestos free, treated
with water repellant.
Steel Straps/Base: Carbon Steel
ASTM A-36.
Fasteners: ASTM A-307 plated.
Slide Pad: UHMW Polyethylene (Teflon
Optional).
Coating: Primer coated or hot dipped
galvanized. Other coatings available
upon request.
Note:
For higher load ratings, see BP8252
For greater axial travel, see BP8261
For lateral restraint, see BP8231
Pipe Vert.
Size Load
1" Thk.
L = +/- 1-1/2
B C
E
1 1/2" Thk.
L = +/- 1-3/4
B C
E
1/2
3/4
1
1 1/2
2
2 1/2
3
4
5
6
8
10
12
14
16
18
20
24
30
36
42
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
6
6
6
4 7.25
4 7.25
4 7.75
4 8.75
4 8.75
4 9.75
4 9.75
4 10.25
4 11
4 11.5
4 12.5
4 13.5
4 14.5
4 15
6 16
6 17
6 18
6 20
6 25
6 29
6 33.5
310
380
490
700
810
990
1140
1810
2260
2750
3660
4310
4740
5380
6240
6890
7320
7750
10110
11830
13340
5.25
5.25
5.75
6.25
6.75
7.25
7.75
8.25
9
9.5
10.5
11.5
12.5
13
14
15
16
18.5
23.5
27.5
32
3.25
3.25
3.875
4.5
5
5.5
6.187
7.25
8.5
9.5
11.625
13.875
16.125
17.125
19.375
21.375
23.375
27.375
33.625
40.125
46.125
6.25
6.25
6.75
7.25
7.75
8.75
8.75
9.25
10
10.5
11.5
12.5
13.5
14
15
16
17
19.5
24
28.5
32.5
4.375
4.375
5
5.5
6.0625
7.125
7.125
8.25
9.5
10.5
12.625
15.125
17.125
18.125
20.375
22.375
24.375
28.375
34.625
41.125
47.125
2" Thk.
L = +/- 2
C
E
5.375
5.375
6.062
7.125
7.125
8.125
8.125
9.25
10.5
11.625
13.625
16.125
18.125
19.125
21.375
23.375
25.375
29.375
35.625
42.125
48.125
2 1/2" Thk.
L = +/- 2-1/4
B C
E
3" Thk.
L = +/- 2-1/2
B C
E
4 8.75
4 8.75
4 8.75
4 9.75
4 9.75
4 10.75
4 10.75
4 11.25
4 12
4 12.5
6 13.5
6 14.5
6 15.5
6 16
6 17
6 18
6 19
6 21
6 25.5
6 29.5
6 34
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
8
8
8
8
8
8
8
7
7
7
8.125
8.125
9.125
9.125
10.25
11.625
12.625
14.875
17.125
19.125
20.125
22.375
24.375
26.375
30.375
36.625
43.125
49.125
9.75
9.75
9.75
10.75
10.75
11.75
11.75
12.25
13
13.5
14.5
15.5
16.5
17
18
19
20
22
26
30.5
34.5
8
8
8
9.125
9.125
10.125
10.125
11.375
12.625
13.625
15.875
18.125
20.125
21.125
23.375
25.375
27.375
31.375
37.625
44.125
50.125
4" Thk.
L = +/- 3
C
E
11.75
11.75
11.75
12.75
12.75
13.75
13.75
14.25
15
15.5
16.5
17.5
18.5
19
20
21
22
24
27.5
32
36
10
10
10
11.25
11.25
12.25
12.375
13.375
14.875
15.875
18.125
20.125
22.125
23.125
25.375
27.375
29.375
33.375
39.625
46.125
52.125
5" Thk.
L = +/- 3-1/2
B C
E
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
13.75
13.75
13.75
14.75
14.75
15.75
15.75
16.25
17
17.5
18.5
19.5
20.5
21
22
23
24
26
29
33.5
37.5
The load ratings represent average values obtained in accordance with accepted methods and are subject to normal manufacturing variations.
---- Dimensions and ratings are subject to change without notice. ----
Easy Installation
Order Information: Specify Quantity Pipe Size & Type Insulation Thickness Figure Number
18
12.125
12.25
12.25
13.25
13.25
14.5
14.625
15.625
16.875
17.875
20.125
22.125
24.125
25.125
27.375
29.375
31.375
35.375
41.625
48.125
54.125
Fig. BP8252
Design Data
BP8252
Temperature Range
Range: +40F to +1200F
Higher temperatures available upon
request.
Insulation: Calcium Silicate asbestos
free, treated with water repellant.
Jackets: Galvanized Steel ASTM A-527.
Glue: Industrial contact adhesive.
Structural inserts: High-density
calcium silicate asbestos free, treated
with water repellant.
Steel Straps/Base: Carbon Steel
ASTM A-36.
Fasteners: ASTM A-307 plated.
Slide Pad: UHMW Polyethylene (Teflon
Optional).
Coating: Primer coated or hot dipped
galvanized. Other coatings available
upon request.
Note:
For higher load ratings, see BP8253
For greater axial travel, see BP8262
For lateral restraint, see BP8232
Pipe Vert.
Size Load
1" Thk.
L = +/- 1-1/2
B C
E
1 1/2" Thk.
L = +/- 1-3/4
B C
E
1/2
3/4
1
1 1/2
2
2 1/2
3
4
5
6
8
10
12
14
16
18
20
24
30
36
42
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
6
6
6
4 7.25
4 7.25
4 7.75
4 8.75
4 8.75
4 9.75
4 9.75
4 10.25
4 11
4 11.5
4 12.5
4 13.5
4 14.5
4 15
6 16
6 17
6 18
6 20
6 25
6 29
6 33.5
400
500
650
950
1100
1350
1600
2500
3100
3800
5100
6000
6600
7500
8700
9600
10200
10800
14100
16500
18600
5.25
5.25
5.75
6.25
6.75
7.25
7.75
8.25
9
9.5
10.5
11.5
12.5
13
14
15
16
18.5
23.5
27.5
32
3.25
3.25
4
4.5
5
5.5
6.187
7.25
8.5
9.5
11.625
13.875
16.125
17.125
19.375
21.375
23.375
27.375
33.625
40.125
46.125
6.25
6.25
6.75
7.25
7.75
8.75
8.75
9.25
10
10.5
11.5
12.5
13.5
14
15
16
17
19.5
24
28.5
32.5
4.375
4.375
5
5.5
6.1875
7.125
7.125
8.25
9.5
10.5
12.625
15.125
17.125
18.125
20.375
22.375
24.375
28.375
34.625
41.125
47.125
2" Thk.
L = +/- 2
C
E
5.375
5.375
6.062
7.125
7.125
8.125
8.125
9.25
10.5
11.625
13.625
16.125
18.125
19.125
21.375
23.375
25.375
29.375
35.625
42.125
48.125
2 1/2" Thk.
L = +/- 2-1/4
B C
E
3" Thk.
L = +/- 2-1/2
B C
E
4 8.75
4 8.75
4 8.75
4 9.75
4 9.75
4 10.75
4 10.75
4 11.25
4 12
4 12.5
6 13.5
6 14.5
6 15.5
6 16
6 17
6 18
6 19
6 21
6 25.5
6 29.5
6 34
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
8
8
8
8
8
8
8
7
7
7.125
8.125
8.125
9.125
9.125
10.25
11.625
12.625
14.875
17.125
19.125
20.125
22.375
24.375
26.375
30.375
36.625
43.125
49.125
9.75
9.75
9.75
10.75
10.75
11.75
11.75
12.25
13
13.5
14.5
15.5
16.5
17
18
19
20
22
26
30.5
34.5
8
8
8.125
9.125
9.125
10.125
10.125
11.375
12.625
13.625
15.875
18.125
20.125
21.125
23.375
25.375
27.375
31.375
37.625
44.125
50.125
4" Thk.
L = +/- 3
C
E
11.75
11.75
11.75
12.75
12.75
13.75
13.75
14.25
15
15.5
16.5
17.5
18.5
19
20
21
22
24
27.5
32
36
10
10
10.125
11.25
11.25
12.25
12.375
13.375
14.875
15.875
18.125
20.125
22.125
23.125
25.375
27.375
29.375
33.375
39.625
46.125
52.125
5" Thk.
L = +/- 3-1/2
B C
E
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
13.75
13.75
13.75
14.75
14.75
15.75
15.75
16.25
17
17.5
18.5
19.5
20.5
21
22
23
24
26
29
33.5
37.5
12.125
12.25
12.25
13.25
13.25
14.5
14.625
15.625
16.875
17.875
20.125
22.125
24.125
25.125
27.375
29.375
31.375
35.375
41.625
48.125
54.125
The load ratings represent average values obtained in accordance with accepted methods and are subject to normal manufacturing variations.
---- Dimensions and ratings are subject to change without notice. ----
Easy Installation
Order Information: Specify Quantity Pipe Size & Type Insulation Thickness Figure Number
19
Fig. BP8253
BP8253
Design Data
Temperature Range
Range: +40F to +1200F
Higher temperatures available upon
request.
Insulation: Calcium Silicate asbestos
free, treated with water repellant.
Jackets: Galvanized Steel ASTM A-527.
Glue: Industrial contact adhesive.
Structural inserts: High-density
calcium silicate asbestos free, treated
with water repellant.
Steel Straps/Base: Carbon Steel
ASTM A-36.
Fasteners: ASTM A-307 plated.
Slide Pad: UHMW Polyethylene (Teflon
Optional).
Coating: Primer coated or hot dipped
galvanized. Other coatings available
upon request.
Note:
For greater axial travel, see BP8263
For lateral restraint, see BP8233
Pipe Vert.
Size Load
1" Thk.
L = +/- 1-1/2
B C
E
1 1/2" Thk.
L = +/- 1-3/4
B C
E
1/2
3/4
1
1 1/2
2
2 1/2
3
4
5
6
8
10
12
14
16
18
20
24
30
36
42
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
6
6
6
4 7.25
4 7.25
4 7.75
4 8.75
4 8.75
4 9.75
4 9.75
4 10.25
4 11
4 11.5
4 12.5
4 13.5
4 14.5
4 15
6 16
6 17
6 18
6 20
6 25
6 29
6 33.5
550
700
900
1300
1500
1800
2100
3350
4200
5100
6800
8000
8800
10000
11600
12800
13600
14400
18800
22000
24800
5.25
5.25
5.75
6.25
6.75
7.25
7.75
8.25
9
9.5
10.5
11.5
12.5
13
14
15
16
18.5
23.5
27.5
32
3.375
3.375
4
4.5
5
5.5
6.187
7.25
8.5
9.5
11.625
13.875
16.125
17.125
19.375
21.375
23.375
27.375
33.625
40.125
46.125
6.25
6.25
6.75
7.25
7.75
8.75
8.75
9.25
10
10.5
11.5
12.5
13.5
14
15
16
17
19.5
24
28.5
32.5
4.5
4.5
5
5.5
6.0625
7.125
7.125
8.25
9.5
10.5
12.625
15.125
17.125
18.125
20.375
22.375
24.375
28.375
34.625
41.125
47.125
2" Thk.
L = +/- 2
C
E
5.5
5.5
6.062
7.125
7.125
8.125
8.125
9.25
10.5
11.625
13.625
16.125
18.125
19.125
21.375
23.375
25.375
29.375
35.625
42.125
48.125
2 1/2" Thk.
L = +/- 2-1/4
B C
E
3" Thk.
L = +/- 2-1/2
B C
E
4 8.75
4 8.75
4 8.75
4 9.75
4 9.75
4 10.75
4 10.75
4 11.25
4 12
4 12.5
6 13.5
6 14.5
6 15.5
6 16
6 17
6 18
6 19
6 21
6 25.5
6 29.5
6 34
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
8
8
8
8
8
8
8
7.125
7.125
7.125
8.125
8.125
9.125
9.125
10.25
11.625
12.625
14.875
17.125
19.125
20.125
22.375
24.375
26.375
30.375
36.625
43.125
49.125
9.75
9.75
9.75
10.75
10.75
11.75
11.75
12.25
13
13.5
14.5
15.5
16.5
17
18
19
20
22
26
30.5
34.5
8.125
8.125
8.125
9.125
9.125
10.125
10.125
11.375
12.625
13.625
15.875
18.125
20.125
21.125
23.375
25.375
27.375
31.375
37.625
44.125
50.125
4" Thk.
L = +/- 3
C
E
11.75
11.75
11.75
12.75
12.75
13.75
13.75
14.25
15
15.5
16.5
17.5
18.5
19
20
21
22
24
27.5
32
36
10.125
10.125
10.125
11.25
11.25
12.375
12.375
13.375
14.875
15.875
18.125
20.125
22.125
23.125
25.375
27.375
29.375
33.375
39.625
46.125
52.125
5" Thk.
L = +/- 3-1/2
B C
E
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
13.75
13.75
13.75
14.75
14.75
15.75
15.75
16.25
17
17.5
18.5
19.5
20.5
21
22
23
24
26
29
33.5
37.5
The load ratings represent average values obtained in accordance with accepted methods and are subject to normal manufacturing variations.
---- Dimensions and ratings are subject to change without notice. ----
Easy Installation
Order Information: Specify Quantity Pipe Size & Type Insulation Thickness Figure Number
20
12.25
12.25
12.25
13.25
13.25
14.625
14.625
15.625
16.875
17.875
20.125
22.125
24.125
25.125
27.375
29.375
31.375
35.375
41.625
48.125
54.125
Fig. BP8260
Design Data
BP8260
Temperature Range
Range: +40F to +1200F
Higher temperatures available upon
request.
Insulation: Calcium Silicate asbestos
free, treated with water repellant.
Jackets: Galvanized Steel ASTM A-527.
Glue: Industrial contact adhesive.
Structural inserts: High-density
calcium silicate asbestos free, treated
with water repellant.
Steel Straps/Base: Carbon Steel
ASTM A-36.
Fasteners: ASTM A-307 plated.
Slide Pad: UHMW Polyethylene (Teflon
Optional).
Coating: Primer coated or hot dipped
galvanized. Other coatings available
upon request.
Note:
For higher load ratings, see BP8261
For lateral restraint, see BP8240
Pipe Vert.
Size Load
1" Thk.
L = +/- 1-1/2
B C
E
1 1/2" Thk.
L = +/- 1-3/4
B C
E
1/2
3/4
1
1 1/2
2
2 1/2
3
4
5
6
8
10
12
14
16
18
20
24
30
36
42
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
6
6
6
4 7.25
4 7.25
4 7.75
4 8.75
4 8.75
4 9.75
4 9.75
4 10.25
4 11
4 11.5
4 12.5
4 13.5
4 14.5
4 15
6 16
6 17
6 18
6 20
6 25
6 29
6 33.5
160
190
250
350
410
500
570
910
1130
1380
1830
2160
2370
2690
3120
3450
3660
3880
5060
5920
6670
5.25
5.25
5.75
6.25
6.75
7.25
7.75
8.25
9
9.5
10.5
11.5
12.5
13
14
15
16
18.5
23.5
27.5
32
3.25
3.25
3.875
4.375
5
5.5
6.062
7.25
8.25
9.25
11.625
13.625
16.125
17.125
19.125
21.375
23.375
27.375
33.625
39.625
46.125
6.25
6.25
6.75
7.25
7.75
8.75
8.75
9.25
10
10.5
11.5
12.5
13.5
14
15
16
17
19.5
24
28.5
32.5
4.375
4.375
4.875
5.5
6.0625
7.125
7.125
8.25
9.25
10.25
12.625
14.875
17.125
18.125
20.125
22.375
24.375
28.375
34.625
41.125
47.125
2" Thk.
L = +/- 2
C
E
5.375
5.375
5.937
7
7
8.125
8.125
9.25
10.25
11.375
13.625
15.875
18.125
19.125
21.375
23.375
25.375
29.375
35.625
42.125
48.125
2 1/2" Thk.
L = +/- 2-1/4
B C
E
3" Thk.
L = +/- 2-1/2
B C
E
4 8.75
4 8.75
4 8.75
4 9.75
4 9.75
4 10.75
4 10.75
4 11.25
4 12
4 12.5
6 13.5
6 14.5
6 15.5
6 16
6 17
6 18
6 19
6 21
6 25.5
6 29.5
6 34
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
8
8
8
8
8
8
8
7
7
7
8
8
9.125
9.125
10.25
11.375
12.625
14.875
16.875
19.125
20.125
22.375
24.375
26.375
30.375
36.625
43.125
49.125
9.75
9.75
9.75
10.75
10.75
11.75
11.75
12.25
13
13.5
14.5
15.5
16.5
17
18
19
20
22
26
30.5
34.5
8
8
8
9
9.125
10.125
10.125
11.375
12.375
13.625
15.875
18.125
20.125
21.125
23.375
25.375
27.375
31.375
37.625
44.125
50.125
4" Thk.
L = +/- 3
C
E
11.75
11.75
11.75
12.75
12.75
13.75
13.75
14.25
15
15.5
16.5
17.5
18.5
19
20
21
22
24
27.5
32
36
10
10
10
11.25
11.25
12.25
12.375
13.375
14.875
15.875
17.875
20.125
22.125
23.125
25.375
27.375
29.375
33.375
39.625
46.125
52.125
5" Thk.
L = +/- 3-1/2
B C
E
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
13.75
13.75
13.75
14.75
14.75
15.75
15.75
16.25
17
17.5
18.5
19.5
20.5
21
22
23
24
26
29
33.5
37.5
12.125
12.125
12.25
13.25
13.25
14.5
14.625
15.625
16.875
17.875
20.125
22.125
24.125
25.125
27.375
29.375
31.375
35.375
41.625
48.125
54.125
The load ratings represent average values obtained in accordance with accepted methods and are subject to normal manufacturing variations.
---- Dimensions and ratings are subject to change without notice. ----
Easy Installation
Order Information: Specify Quantity Pipe Size & Type Insulation Thickness Figure Number
21
Fig. BP8261
BP8261
Design Data
Temperature Range
Range: +40F to +1200F
Higher temperatures available upon
request.
Insulation: Calcium Silicate asbestos
free, treated with water repellant.
Jackets: Galvanized Steel ASTM A-527.
Glue: Industrial contact adhesive.
Structural inserts: High-density
calcium silicate asbestos free, treated
with water repellant.
Steel Straps/Base: Carbon Steel
ASTM A-36.
Fasteners: ASTM A-307 plated.
Slide Pad: UHMW Polyethylene (Teflon
Optional).
Coating: Primer coated or hot dipped
galvanized. Other coatings available
upon request.
Note:
For higher load ratings, see BP8262
For lateral restraint, see BP8241
Pipe Vert.
Size Load
1" Thk.
L = +/- 1-1/2
B C
E
1 1/2" Thk.
L = +/- 1-3/4
B C
E
1/2
3/4
1
1 1/2
2
2 1/2
3
4
5
6
8
10
12
14
16
18
20
24
30
36
42
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
6
6
6
4 7.25
4 7.25
4 7.75
4 8.75
4 8.75
4 9.75
4 9.75
4 10.25
4 11
4 11.5
4 12.5
4 13.5
4 14.5
4 15
6 16
6 17
6 18
6 20
6 25
6 29
6 33.5
310
380
490
700
810
990
1140
1810
2260
2750
3660
4310
4740
5380
6240
6890
7320
7750
10110
11830
13340
5.25
5.25
5.75
6.25
6.75
7.25
7.75
8.25
9
9.5
10.5
11.5
12.5
13
14
15
16
18.5
23.5
27.5
32
3.25
3.25
3.875
4.5
5
5.5
6.187
7.25
8.5
9.5
11.625
13.875
16.125
17.125
19.375
21.375
23.375
27.375
33.625
40.125
46.125
6.25
6.25
6.75
7.25
7.75
8.75
8.75
9.25
10
10.5
11.5
12.5
13.5
14
15
16
17
19.5
24
28.5
32.5
4.375
4.375
5
5.5
6.0625
7.125
7.125
8.25
9.5
10.5
12.625
15.125
17.125
18.125
20.375
22.375
24.375
28.375
34.625
41.125
47.125
2" Thk.
L = +/- 2
C
E
5.375
5.375
6.062
7.125
7.125
8.125
8.125
9.25
10.5
11.625
13.625
16.125
18.125
19.125
21.375
23.375
25.375
29.375
35.625
42.125
48.125
2 1/2" Thk.
L = +/- 2-1/4
B C
E
3" Thk.
L = +/- 2-1/2
B C
E
4 8.75
4 8.75
4 8.75
4 9.75
4 9.75
4 10.75
4 10.75
4 11.25
4 12
4 12.5
6 13.5
6 14.5
6 15.5
6 16
6 17
6 18
6 19
6 21
6 25.5
6 29.5
6 34
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
8
8
8
8
8
8
8
7
7
7
8.125
8.125
9.125
9.125
10.25
11.625
12.625
14.875
17.125
19.125
20.125
22.375
24.375
26.375
30.375
36.625
43.125
49.125
9.75
9.75
9.75
10.75
10.75
11.75
11.75
12.25
13
13.5
14.5
15.5
16.5
17
18
19
20
22
26
30.5
34.5
8
8
8
9.125
9.125
10.125
10.125
11.375
12.625
13.625
15.875
18.125
20.125
21.125
23.375
25.375
27.375
31.375
37.625
44.125
50.125
4" Thk.
L = +/- 3
C
E
11.75
11.75
11.75
12.75
12.75
13.75
13.75
14.25
15
15.5
16.5
17.5
18.5
19
20
21
22
24
27.5
32
36
10
10
10
11.25
11.25
12.25
12.375
13.375
14.875
15.875
18.125
20.125
22.125
23.125
25.375
27.375
29.375
33.375
39.625
46.125
52.125
5" Thk.
L = +/- 3-1/2
B C
E
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
13.75
13.75
13.75
14.75
14.75
15.75
15.75
16.25
17
17.5
18.5
19.5
20.5
21
22
23
24
26
29
33.5
37.5
The load ratings represent average values obtained in accordance with accepted methods and are subject to normal manufacturing variations.
---- Dimensions and ratings are subject to change without notice. ----
Easy Installation
Order Information: Specify Quantity Pipe Size & Type Insulation Thickness Figure Number
22
12.125
12.25
12.25
13.25
13.25
14.5
14.625
15.625
16.875
17.875
20.125
22.125
24.125
25.125
27.375
29.375
31.375
35.375
41.625
48.125
54.125
Fig. BP8262
Design Data
BP8262
Temperature Range
Range: +40F to +1200F
Higher temperatures available upon
request.
Insulation: Calcium Silicate asbestos
free, treated with water repellant.
Jackets: Galvanized Steel ASTM A-527.
Glue: Industrial contact adhesive.
Structural inserts: High-density
calcium silicate asbestos free, treated
with water repellant.
Steel Straps/Base: Carbon Steel
ASTM A-36.
Fasteners: ASTM A-307 plated.
Slide Pad: UHMW Polyethylene (Teflon
Optional).
Coating: Primer coated or hot dipped
galvanized. Other coatings available
upon request.
Note:
For higher load ratings, see BP8263
For lateral restraint, see BP8242
Pipe Vert.
Size Load
1" Thk.
L = +/- 1-1/2
B C
E
1 1/2" Thk.
L = +/- 1-3/4
B C
E
1/2
3/4
1
1 1/2
2
2 1/2
3
4
5
6
8
10
12
14
16
18
20
24
30
36
42
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
6
6
6
4 7.25
4 7.25
4 7.75
4 8.75
4 8.75
4 9.75
4 9.75
4 10.25
4 11
4 11.5
4 12.5
4 13.5
4 14.5
4 15
6 16
6 17
6 18
6 20
6 25
6 29
6 33.5
440
540
700
1030
1190
1460
1730
2690
3340
4090
5490
6460
7100
8070
9360
10330
10970
11620
15170
17750
20000
5.25
5.25
5.75
6.25
6.75
7.25
7.75
8.25
9
9.5
10.5
11.5
12.5
13
14
15
16
18.5
23.5
27.5
32
3.25
3.25
4
4.5
5
5.5
6.187
7.25
8.5
9.5
11.625
13.875
16.125
17.125
19.375
21.375
23.375
27.375
33.625
40.125
46.125
6.25
6.25
6.75
7.25
7.75
8.75
8.75
9.25
10
10.5
11.5
12.5
13.5
14
15
16
17
19.5
24
28.5
32.5
4.375
4.375
5
5.5
6.1875
7.125
7.125
8.25
9.5
10.5
12.625
15.125
17.125
18.125
20.375
22.375
24.375
28.375
34.625
41.125
47.125
2" Thk.
L = +/- 2
C
E
5.375
5.375
6.062
7.125
7.125
8.125
8.125
9.25
10.5
11.625
13.625
16.125
18.125
19.125
21.375
23.375
25.375
29.375
35.625
42.125
48.125
2 1/2" Thk.
L = +/- 2-1/4
B C
E
3" Thk.
L = +/- 2-1/2
B C
E
4 8.75
4 8.75
4 8.75
4 9.75
4 9.75
4 10.75
4 10.75
4 11.25
4 12
4 12.5
6 13.5
6 14.5
6 15.5
6 16
6 17
6 18
6 19
6 21
6 25.5
6 29.5
6 34
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
8
8
8
8
8
8
8
7
7
7.125
8.125
8.125
9.125
9.125
10.25
11.625
12.625
14.875
17.125
19.125
20.125
22.375
24.375
26.375
30.375
36.625
43.125
49.125
9.75
9.75
9.75
10.75
10.75
11.75
11.75
12.25
13
13.5
14.5
15.5
16.5
17
18
19
20
22
26
30.5
34.5
8
8
8.125
9.125
9.125
10.125
10.125
11.375
12.625
13.625
15.875
18.125
20.125
21.125
23.375
25.375
27.375
31.375
37.625
44.125
50.125
4" Thk.
L = +/- 3
C
E
11.75
11.75
11.75
12.75
12.75
13.75
13.75
14.25
15
15.5
16.5
17.5
18.5
19
20
21
22
24
27.5
32
36
10
10
10.125
11.25
11.25
12.25
12.375
13.375
14.875
15.875
18.125
20.125
22.125
23.125
25.375
27.375
29.375
33.375
39.625
46.125
52.125
5" Thk.
L = +/- 3-1/2
B C
E
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
13.75
13.75
13.75
14.75
14.75
15.75
15.75
16.25
17
17.5
18.5
19.5
20.5
21
22
23
24
26
29
33.5
37.5
12.125
12.25
12.25
13.25
13.25
14.5
14.625
15.625
16.875
17.875
20.125
22.125
24.125
25.125
27.375
29.375
31.375
35.375
41.625
48.125
54.125
The load ratings represent average values obtained in accordance with accepted methods and are subject to normal manufacturing variations.
---- Dimensions and ratings are subject to change without notice. ----
Easy Installation
Order Information: Specify Quantity Pipe Size & Type Insulation Thickness Figure Number
23
Fig. BP8263
BP8263
Design Data
Temperature Range
Range: +40F to +1200F
Higher temperatures available upon
request.
Insulation: Calcium Silicate asbestos
free, treated with water repellant.
Jackets: Galvanized Steel ASTM A-527.
Glue: Industrial contact adhesive.
Structural inserts: High-density
calcium silicate asbestos free, treated
with water repellant.
Steel Straps/Base: Carbon Steel
ASTM A-36.
Fasteners: ASTM A-307 plated.
Slide Pad: UHMW Polyethylene (Teflon
Optional).
Coating: Primer coated or hot dipped
galvanized. Other coatings available
upon request.
Note:
For lateral restraint, see BP8243
Pipe Vert.
Size Load
1" Thk.
L = +/- 1-1/2
B C
E
1 1/2" Thk.
L = +/- 1-3/4
B C
E
1/2
3/4
1
1 1/2
2
2 1/2
3
4
5
6
8
10
12
14
16
18
20
24
30
36
42
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
6
6
6
4 7.25
4 7.25
4 7.75
4 8.75
4 8.75
4 9.75
4 9.75
4 10.25
4 11
4 11.5
4 12.5
4 13.5
4 14.5
4 15
6 16
6 17
6 18
6 20
6 25
6 29
6 33.5
600
760
970
1400
1620
1940
2260
3610
4520
5490
7320
8610
9470
10760
12480
13770
14630
15490
20220
23660
26670
5.25
5.25
5.75
6.25
6.75
7.25
7.75
8.25
9
9.5
10.5
11.5
12.5
13
14
15
16
18.5
23.5
27.5
32
3.375
3.375
4
4.5
5
5.5
6.187
7.25
8.5
9.5
11.625
13.875
16.125
17.125
19.375
21.375
23.375
27.375
33.625
40.125
46.125
6.25
6.25
6.75
7.25
7.75
8.75
8.75
9.25
10
10.5
11.5
12.5
13.5
14
15
16
17
19.5
24
28.5
32.5
4.5
4.5
5
5.5
6.0625
7.125
7.125
8.25
9.5
10.5
12.625
15.125
17.125
18.125
20.375
22.375
24.375
28.375
34.625
41.125
47.125
2" Thk.
L = +/- 2
C
E
5.5
5.5
6.062
7.125
7.125
8.125
8.125
9.25
10.5
11.625
13.625
16.125
18.125
19.125
21.375
23.375
25.375
29.375
35.625
42.125
48.125
2 1/2" Thk.
L = +/- 2-1/4
B C
E
3" Thk.
L = +/- 2-1/2
B C
E
4 8.75
4 8.75
4 8.75
4 9.75
4 9.75
4 10.75
4 10.75
4 11.25
4 12
4 12.5
6 13.5
6 14.5
6 15.5
6 16
6 17
6 18
6 19
6 21
6 25.5
6 29.5
6 34
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
8
8
8
8
8
8
8
7.125
7.125
7.125
8.125
8.125
9.125
9.125
10.25
11.625
12.625
14.875
17.125
19.125
20.125
22.375
24.375
26.375
30.375
36.625
43.125
49.125
9.75
9.75
9.75
10.75
10.75
11.75
11.75
12.25
13
13.5
14.5
15.5
16.5
17
18
19
20
22
26
30.5
34.5
8.125
8.125
8.125
9.125
9.125
10.125
10.125
11.375
12.625
13.625
15.875
18.125
20.125
21.125
23.375
25.375
27.375
31.375
37.625
44.125
50.125
4" Thk.
L = +/- 3
C
E
11.75
11.75
11.75
12.75
12.75
13.75
13.75
14.25
15
15.5
16.5
17.5
18.5
19
20
21
22
24
27.5
32
36
10.125
10.125
10.125
11.25
11.25
12.375
12.375
13.375
14.875
15.875
18.125
20.125
22.125
23.125
25.375
27.375
29.375
33.375
39.625
46.125
52.125
5" Thk.
L = +/- 3-1/2
B C
E
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
13.75
13.75
13.75
14.75
14.75
15.75
15.75
16.25
17
17.5
18.5
19.5
20.5
21
22
23
24
26
29
33.5
37.5
The load ratings represent average values obtained in accordance with accepted methods and are subject to normal manufacturing variations.
---- Dimensions and ratings are subject to change without notice. ----
Easy Installation
Order Information: Specify Quantity Pipe Size & Type Insulation Thickness Figure Number
24
12.25
12.25
12.25
13.25
13.25
14.625
14.625
15.625
16.875
17.875
20.125
22.125
24.125
25.125
27.375
29.375
31.375
35.375
41.625
48.125
54.125
Fig. BP8270
Design Data
BP8270
Temperature Range
Range: +40F to +1200F
Higher temperatures available upon
request.
Insulation: Calcium Silicate asbestos
free, treated with water repellant.
Jackets: Galvanized Steel ASTM A-527.
Glue: Industrial contact adhesive.
Structural inserts: High-density
calcium silicate asbestos free, treated
with water repellant.
Steel Straps/Base: Carbon Steel
ASTM A-36.
Fasteners: ASTM A-307 plated.
Slide Pad: UHMW Polyethylene (Teflon
Optional).
Coating: Primer coated or hot dipped
galvanized. Other coatings available
upon request.
Note:
For higher load ratings, see BP8271
For greater axial travel, see BP8280
For lateral travel, see: BP8250
Pipe
Size
1/2
3/4
1
1 1/2
2
2 1/2
3
4
5
6
8
10
12
14
16
18
20
24
30
36
42
Vert. Lat.
Load Load B
140
170
220
320
370
450
520
810
1020
1230
1620
1940
2100
2420
2800
3070
3280
3450
4520
5270
5970
70
85
110
160
185
225
260
405
510
615
810
970
1050
1210
1400
1535
1640
1725
2260
2635
2985
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
1" Thk.
C
E
3.5
3.5
4
4
4.5
4.5
6.5
7.5
8
9
11
13.5
15
16
17.5
19.5
21
24
29.5
34
39
3.25
3.25
3.875
4.375
5
5.5
6.062
7.25
8.25
9.25
11.625
13.625
16.125
17.125
19.125
21.375
23.375
27.375
33.625
39.625
46.125
1 1/2" Thk.
C
E
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
6
6
6
4
4
4.5
4.5
5
6
7.5
8
9
10
11.5
14
15.5
17
18
20
21.5
25
30
35
39.5
4
4
4
4
4
4
4
4
4
4
4
4
4
4
6
6
6
6
6
6
6
4.375
4.375
4.875
5.5
6.0625
7.125
7.125
8.25
9.25
10.25
12.625
14.875
17.125
18.125
20.125
22.375
24.375
28.375
34.625
41.125
47.125
2" Thk.
C
E
4.5
4.5
5
6
6
6.5
8
9
10
11
12.5
15
16.5
17.5
19
21
22
25.5
31
35.5
40.5
5.375
5.375
5.937
7
7
8.125
8.125
9.25
10.25
11.375
13.625
15.875
18.125
19.125
21.375
23.375
25.375
29.375
35.625
42.125
48.125
2 1/2" Thk.
C
E
4
4
4
4
4
4
4
4
4
4
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6.5
6.5
7.5
9
10
11
11.5
13
15.5
17
18
19.5
21.5
23
26.5
31.5
36
41
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
7
7
7
8
8
9.125
9.125
10.25
11.375
12.625
14.875
16.875
19.125
20.125
22.375
24.375
26.375
30.375
36.625
43.125
49.125
3" Thk.
C
E
6.5
6.5
6.5
7.5
7.5
8.5
10
11
11.5
12.5
14
16.5
17.5
19
20.5
22
23.5
27
32
37
41.5
8
8
8
9
9.125
10.125
10.125
11.375
12.375
13.625
15.875
18.125
20.125
21.125
23.375
25.375
27.375
31.375
37.625
44.125
50.125
B
6
6
6
6
6
6
6
6
6
6
6
6
6
6
8
8
8
8
8
8
8
4" Thk.
C
E
8.5
8.5
8.5
9.5
9.5
10
11.5
12.5
13
14
15.5
17.5
19
20.5
21.5
23.5
25
28.5
33.5
38.5
43
10
10
10
11.25
11.25
12.25
12.375
13.375
14.875
15.875
17.875
20.125
22.125
23.125
25.375
27.375
29.375
33.375
39.625
46.125
52.125
B
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
5" Thk.
C
E
10
10
10
11
11
11.5
13
14
14.5
15.5
16.5
19
20.5
21.5
23
25
26.5
30
35
40
44.5
12.125
12.125
12.25
13.25
13.25
14.5
14.625
15.625
16.875
17.875
20.125
22.125
24.125
25.125
27.375
29.375
31.375
35.375
41.625
48.125
54.125
The load ratings represent average values obtained in accordance with accepted methods and are subject to normal manufacturing variations.
---- Dimensions and ratings are subject to change without notice. ----
Easy Installation
Order Information: Specify Quantity Pipe Size & Type Insulation Thickness Figure Number
25
Fig. BP8271
BP8271
Design Data
Temperature Range
Range: +40F to +1200F
Higher temperatures available upon
request.
Insulation: Calcium Silicate asbestos
free, treated with water repellant.
Jackets: Galvanized Steel ASTM A-527.
Glue: Industrial contact adhesive.
Structural inserts: High-density
calcium silicate asbestos free, treated
with water repellant.
Steel Straps/Base: Carbon Steel
ASTM A-36.
Fasteners: ASTM A-307 plated.
Slide Pad: UHMW Polyethylene (Teflon
Optional).
Coating: Primer coated or hot dipped
galvanized. Other coatings available
upon request.
Note:
For higher load ratings, see BP8272
For greater axial travel, see BP8281
For lateral travel, see BP8251
Pipe
Size
1/2
3/4
1
1 1/2
2
2 1/2
3
4
5
6
8
10
12
14
16
18
20
24
30
36
42
Vert. Lat.
Load Load B
270
340
440
630
730
890
1030
1620
2030
2460
3230
3880
4200
4840
5600
6130
6560
6890
9040
10540
11940
135
170
220
315
365
445
515
810
1015
1230
1615
1940
2100
2420
2800
3065
3280
3445
4520
5270
5970
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
1" Thk.
C
E
5
5
5.5
5.5
6
6.5
7
8.5
9.5
10
13
14.5
16.5
17.5
19
21
22.5
25.5
31.5
36
41.5
3.25
3.25
3.875
4.5
5
5.5
6.187
7.25
8.5
9.5
11.625
13.875
16.125
17.125
19.375
21.375
23.375
27.375
33.625
40.125
46.125
1 1/2" Thk.
C
E
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
6
6
6
5.5
5.5
6
6
6.5
8
8
9
10.5
11
13.5
15
17
18.5
19.5
21.5
23
26.5
32
37
42
4
4
4
4
4
4
4
4
4
4
4
4
4
4
6
6
6
6
6
6
6
4.375
4.375
5
5.5
6.0625
7.125
7.125
8.25
9.5
10.5
12.625
15.125
17.125
18.125
20.375
22.375
24.375
28.375
34.625
41.125
47.125
2" Thk.
C
E
6
6
6.5
7.5
7.5
8.5
8.5
10
11.5
12
14.5
16
18
19
20.5
22.5
23.5
27
33
37.5
43
5.375
5.375
6.062
7.125
7.125
8.125
8.125
9.25
10.5
11.625
13.625
16.125
18.125
19.125
21.375
23.375
25.375
29.375
35.625
42.125
48.125
2 1/2" Thk.
C
E
4
4
4
4
4
4
4
4
4
4
6
6
6
6
6
6
6
6
6
6
6
7.5
7.5
7.5
8
8
9.5
9.5
11
12.5
12.5
15
16.5
18.5
19.5
21
23
24.5
28
33.5
38
43.5
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
7
7
7
8.125
8.125
9.125
9.125
10.25
11.625
12.625
14.875
17.125
19.125
20.125
22.375
24.375
26.375
30.375
36.625
43.125
49.125
3" Thk.
C
E
8
8
8
9
9
10.5
10.5
12
13
13.5
16
17.5
19
20.5
22
23.5
25
28.5
34
39
44
8
8
8
9.125
9.125
10.125
10.125
11.375
12.625
13.625
15.875
18.125
20.125
21.125
23.375
25.375
27.375
31.375
37.625
44.125
50.125
B
6
6
6
6
6
6
6
6
6
6
6
6
6
6
8
8
8
8
8
8
8
4" Thk.
C
E
10
10
10
11
11
12
12
13.5
14.5
15
17.5
18.5
20.5
22
23
25
26.5
30
35.5
40.5
45.5
10
10
10
11.25
11.25
12.25
12.375
13.375
14.875
15.875
18.125
20.125
22.125
23.125
25.375
27.375
29.375
33.375
39.625
46.125
52.125
5" Thk.
C
E
B
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
11.5
11.5
11.5
12.5
12.5
13.5
13.5
15
16
16.5
18.5
20
22
23
24.5
26.5
28
31.5
37
42
47
The load ratings represent average values obtained in accordance with accepted methods and are subject to normal manufacturing variations.
---- Dimensions and ratings are subject to change without notice. ----
Easy Installation
Order Information: Specify Quantity Pipe Size & Type Insulation Thickness Figure Number
26
12.125
12.25
12.25
13.25
13.25
14.5
14.625
15.625
16.875
17.875
20.125
22.125
24.125
25.125
27.375
29.375
31.375
35.375
41.625
48.125
54.125
Fig. BP8272
Design Data
BP8272
Temperature Range
Range: +40F to +1200F
Higher temperatures available upon
request.
Insulation: Calcium Silicate asbestos
free, treated with water repellant.
Jackets: Galvanized Steel ASTM A-527.
Glue: Industrial contact adhesive.
Structural inserts: High-density
calcium silicate asbestos free, treated
with water repellant.
Steel Straps/Base: Carbon Steel
ASTM A-36.
Fasteners: ASTM A-307 plated.
Slide Pad: UHMW Polyethylene (Teflon
Optional).
Coating: Primer coated or hot dipped
galvanized. Other coatings available
upon request.
Note:
For higher load ratings, see BP8273
For greater axial travel, see BP8282
For lateral travel, see BP8252
Pipe
Size
1/2
3/4
1
1 1/2
2
2 1/2
3
4
5
6
8
10
12
14
16
18
20
24
30
36
42
Vert. Lat.
Load Load B
410
500
650
940
1090
1330
1540
2420
3040
3680
4840
5810
6300
7260
8390
9200
9840
10330
13550
15810
17910
205
250
325
470
545
665
770
1210
1520
1840
2420
2905
3150
3630
4195
4600
4920
5165
6775
7905
8955
1" Thk.
C
E
1 1/2" Thk.
C
E
2" Thk.
C
E
2 1/2" Thk.
C
E
4 5
3.25 4 5.5 4.375 4 6
5.375 4 7.5
7
6
4 5
3.25 4 5.5 4.375 4 6
5.375 4 7.5
7
6
4 5.5
4
4 6
5
4 6.5 6.062 4 7.5 7.125 6
4 6
4.5
4 6.5
5.5
4 8
7.125 4 8.5 8.125 6
4 7
5
4 7.5 6.1875 4 8.5 7.125 4 9
8.125 6
4 7
5.5
4 8.5 7.125 4 9
8.125 4 10 9.125 6
4 7.5 6.187 4 8.5 7.125 4 9
8.125 4 10 9.125 6
4 9.5
7.25 4 10
8.25 4 11
9.25 4 12 10.25 6
4 12.5
8.5
4 13
9.5
4 14.5 10.5 4 16 11.625 6
4 12
9.5
4 13.5 10.5 4 15 11.625 4 16 12.625 6
4 16 11.625 4 17 12.625 4 18.5 13.625 6 19 14.875 6
4 19 13.875 4 19.5 15.125 4 20.5 16.125 6 21 17.125 6
4 21 16.125 4 21.5 17.125 4 22.5 18.125 6 23.5 19.125 6
4 22 17.125 4 23 18.125 4 24 19.125 6 24.5 20.125 6
4 23.5 19.375 4 24 20.375 6 25 21.375 6 26 22.375 6
4 25.5 21.375 4 26.5 22.375 6 27.5 23.375 6 28 24.375 6
4 28 23.375 4 28.5 24.375 6 29 25.375 6 29.5 26.375 6
4 31 27.375 4 32 28.375 6 32.5 29.375 6 33 30.375 6
4 37 33.625 6 38 34.625 6 38.5 35.625 6 39.5 36.625 6
4 43 40.125 6 43.5 41.125 6 44.5 42.125 6 45.5 43.125 6
4 49 46.125 6 50 47.125 6 51 48.125 6 51.5 49.125 6
3" Thk.
C
E
8
8
8
9.5
10
11
11
13
17
17.5
20
22
24
25.5
27
28.5
30
34
40.5
46
52.5
8
8
8.125
9.125
9.125
10.125
10.125
11.375
12.625
13.625
15.875
18.125
20.125
21.125
23.375
25.375
27.375
31.375
37.625
44.125
50.125
B
6
6
6
6
6
6
6
6
6
6
6
6
6
6
8
8
8
8
8
8
8
4" Thk.
C
E
10
10
10
11.5
12
12.5
12.5
14.5
19
18.5
21.5
23.5
26
27.5
28
29.5
31.5
35.5
42
47.5
54
10
10
10.125
11.25
11.25
12.25
12.375
13.375
14.875
15.875
18.125
20.125
22.125
23.125
25.375
27.375
29.375
33.375
39.625
46.125
52.125
B
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
5" Thk.
C
E
11.5
11.5
11.5
13
13.5
14
14
16
20.5
20.5
23
25.5
27.5
28.5
29
31
33
37
43.5
49.5
55.5
12.125
12.25
12.25
13.25
13.25
14.5
14.625
15.625
16.875
17.875
20.125
22.125
24.125
25.125
27.375
29.375
31.375
35.375
41.625
48.125
54.125
The load ratings represent average values obtained in accordance with accepted methods and are subject to normal manufacturing variations.
---- Dimensions and ratings are subject to change without notice. ----
Easy Installation
Order Information: Specify Quantity Pipe Size & Type Insulation Thickness Figure Number
27
Fig. BP8273
BP8273
Design Data
Temperature Range
Range: +40F to +1200F
Higher temperatures available upon
request.
Insulation: Calcium Silicate asbestos
free, treated with water repellant.
Jackets: Galvanized Steel ASTM A-527.
Glue: Industrial contact adhesive.
Structural inserts: High-density
calcium silicate asbestos free, treated
with water repellant.
Steel Straps/Base: Carbon Steel
ASTM A-36.
Fasteners: ASTM A-307 plated.
Slide Pad: UHMW Polyethylene (Teflon
Optional).
Coating: Primer coated or hot dipped
galvanized. Other coatings available
upon request.
Note:
For greater axial travel, see BP8283
For lateral travel, see BP8253
Pipe
Size
1/2
3/4
1
1 1/2
2
2 1/2
3
4
5
6
8
10
12
14
16
18
20
24
30
36
42
Vert. Lat.
Load Load B
540
670
870
1250
1450
1770
2050
3230
4050
4910
6460
7750
8390
9680
11190
12260
13120
13770
18070
21080
23880
270
335
435
625
725
885
1025
1615
2025
2455
3230
3875
4195
4840
5595
6130
6560
6885
9035
10540
11940
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
1" Thk.
C
E
5
5
5.5
6
7
7
8
10
13
13
17
20
21.5
22.5
24.5
26.5
29
31.5
37.5
44
50
3.375
3.375
4
4.5
5
5.5
6.187
7.25
8.5
9.5
11.625
13.875
16.125
17.125
19.375
21.375
23.375
27.375
33.625
40.125
46.125
1 1/2" Thk.
C
E
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
6
6
6
5.5
5.5
6
6.5
7.5
8.5
9
10.5
13.5
14.5
18
20.5
22
23.5
25
27.5
29.5
32.5
38.5
44.5
51
4
4
4
4
4
4
4
4
4
4
4
4
4
4
6
6
6
6
6
6
6
4.5
4.5
5
5.5
6.0625
7.125
7.125
8.25
9.5
10.5
12.625
15.125
17.125
18.125
20.375
22.375
24.375
28.375
34.625
41.125
47.125
2" Thk.
C
E
6
6
6.5
8
8.5
9
9.5
11.5
15
16
19.5
21.5
23
24.5
26
28.5
30
33
39
45.5
52
5.5
5.5
6.062
7.125
7.125
8.125
8.125
9.25
10.5
11.625
13.625
16.125
18.125
19.125
21.375
23.375
25.375
29.375
35.625
42.125
48.125
2 1/2" Thk.
C
E
4
4
4
4
4
4
4
4
4
4
6
6
6
6
6
6
6
6
6
6
6
7.5
7.5
7.5
8.5
9
10
10.5
12.5
16.5
17
20
22
24
25
27
29
30.5
33.5
40
46.5
52.5
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
7.125
7.125
7.125
8.125
8.125
9.125
9.125
10.25
11.625
12.625
14.875
17.125
19.125
20.125
22.375
24.375
26.375
30.375
37.125
43.125
49.125
3" Thk.
C
E
8
8
8
9.5
10
11
11.5
13.5
17.5
18.5
21
23
24.5
26
28
29.5
31
34.5
41
47
53.5
8.125
8.125
8.125
9.125
9.125
10.125
10.125
11.375
12.625
13.625
15.875
18.125
20.125
21.125
23.375
25.375
27.375
31.375
38.125
44.125
50.125
B
6
6
6
6
6
6
6
6
6
6
6
6
6
6
8
8
8
8
8
8
8
4" Thk.
C
E
10
10
10
11.5
12
12.5
13
15
19.5
19.5
22.5
24.5
26.5
28
29
30.5
32.5
36
42.5
48.5
55
10.125
10.125
10.125
11.25
11.25
12.375
12.375
13.375
14.875
15.875
18.125
20.125
22.125
23.375
25.375
27.375
29.375
33.625
40.125
46.125
52.125
5" Thk.
C
E
B
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
11.5
11.5
11.5
13
13.5
14
14.5
16.5
21
21.5
24
26.5
28
29
30
32
34
37.5
44
50.5
56.5
The load ratings represent average values obtained in accordance with accepted methods and are subject to normal manufacturing variations.
---- Dimensions and ratings are subject to change without notice. ----
Easy Installation
Order Information: Specify Quantity Pipe Size & Type Insulation Thickness Figure Number
28
12.25
12.25
12.25
13.25
13.25
14.625
14.625
15.625
16.875
17.875
20.125
22.125
24.375
25.375
27.375
29.375
31.375
35.625
42.125
48.125
54.125
Fig. BP8280
Design Data
BP8280
Temperature Range
Range: +40F to +1200F
Higher temperatures available upon
request.
Insulation: Calcium Silicate asbestos
free, treated with water repellant.
Jackets: Galvanized Steel ASTM A-527.
Glue: Industrial contact adhesive.
Structural inserts: High-density
calcium silicate asbestos free, treated
with water repellant.
Steel Straps/Base: Carbon Steel
ASTM A-36.
Fasteners: ASTM A-307 plated.
Slide Pad: UHMW Polyethylene (Teflon
Optional).
Coating: Primer coated or hot dipped
galvanized. Other coatings available
upon request.
Note:
For higher load ratings, see BP8281
For lateral travel, see BP8260
Pipe
Size
1/2
3/4
1
1 1/2
2
2 1/2
3
4
5
6
8
10
12
14
16
18
20
24
30
36
42
Vert. Lat.
Load Load B
140
170
220
320
370
450
520
810
1020
1230
1620
1940
2100
2420
2800
3070
3280
3450
4520
5270
5970
70
85
110
160
185
225
260
405
510
615
810
970
1050
1210
1400
1535
1640
1725
2260
2635
2985
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
1" Thk.
C
E
3.5
3.5
4
4
4.5
4.5
6.5
7.5
8
9
11
13.5
15
16
17.5
19.5
21
24
29.5
34
39
3.25
3.25
3.875
4.375
5
5.5
6.062
7.25
8.25
9.25
11.625
13.625
16.125
17.125
19.125
21.375
23.375
27.375
33.625
39.625
46.125
B
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
6
6
6
1 1/2" Thk.
C
E
4
4
4.5
4.5
5
6
7.5
8
9
10
11.5
14
15.5
17
18
20
21.5
25
30
35
39.5
4.375
4.375
4.875
5.5
6.0625
7.125
7.125
8.25
9.25
10.25
12.625
14.875
17.125
18.125
20.125
22.375
24.375
28.375
34.625
41.125
47.125
B
4
4
4
4
4
4
4
4
4
4
4
4
4
4
6
6
6
6
6
6
6
2" Thk.
C
E
4.5
4.5
5
6
6
6.5
8
9
10
11
12.5
15
16.5
17.5
19
21
22
25.5
31
35.5
40.5
5.375
5.375
5.937
7
7
8.125
8.125
9.25
10.25
11.375
13.625
15.875
18.125
19.125
21.375
23.375
25.375
29.375
35.625
42.125
48.125
B
4
4
4
4
4
4
4
4
4
4
6
6
6
6
6
6
6
6
6
6
6
2 1/2" Thk.
C
E
6
6
6
6.5
6.5
7.5
9
10
11
11.5
13
15.5
17
18
19.5
21.5
23
26.5
31.5
36
41
7
7
7
8
8
9.125
9.125
10.25
11.375
12.625
14.875
16.875
19.125
20.125
22.375
24.375
26.375
30.375
36.625
43.125
49.125
B
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
3" Thk.
C
E
6.5
6.5
6.5
7.5
7.5
8.5
10
11
11.5
12.5
14
16.5
17.5
19
20.5
22
23.5
27
32
37
41.5
8
8
8
9
9.125
10.125
10.125
11.375
12.375
13.625
15.875
18.125
20.125
21.125
23.375
25.375
27.375
31.375
37.625
44.125
50.125
B
6
6
6
6
6
6
6
6
6
6
6
6
6
6
8
8
8
8
8
8
8
4" Thk.
C
E
8.5
8.5
8.5
9.5
9.5
10
11.5
12.5
13
14
15.5
17.5
19
20.5
21.5
23.5
25
28.5
33.5
38.5
43
10
10
10
11.25
11.25
12.25
12.375
13.375
14.875
15.875
17.875
20.125
22.125
23.125
25.375
27.375
29.375
33.375
39.625
46.125
52.125
B
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
5" Thk.
C
E
10
10
10
11
11
11.5
13
14
14.5
15.5
16.5
19
20.5
21.5
23
25
26.5
30
35
40
44.5
12.125
12.125
12.25
13.25
13.25
14.5
14.625
15.625
16.875
17.875
20.125
22.125
24.125
25.125
27.375
29.375
31.375
35.375
41.625
48.125
54.125
The load ratings represent average values obtained in accordance with accepted methods and are subject to normal manufacturing variations.
---- Dimensions and ratings are subject to change without notice. ----
Easy Installation
Order Information: Specify Quantity Pipe Size & Type Insulation Thickness Figure Number
29
Fig. BP8281
BP8281
Design Data
Temperature Range
Range: +40F to +1200F
Higher temperatures available upon
request.
Insulation: Calcium Silicate asbestos
free, treated with water repellant.
Jackets: Galvanized Steel ASTM A-527.
Glue: Industrial contact adhesive.
Structural inserts: High-density
calcium silicate asbestos free, treated
with water repellant.
Steel Straps/Base: Carbon Steel
ASTM A-36.
Fasteners: ASTM A-307 plated.
Slide Pad: UHMW Polyethylene (Teflon
Optional).
Coating: Primer coated or hot dipped
galvanized. Other coatings available
upon request.
Note:
For higher load ratings, see BP8282
For lateral travel, see BP8261
Pipe
Size
1/2
3/4
1
1 1/2
2
2 1/2
3
4
5
6
8
10
12
14
16
18
20
24
30
36
42
Vert. Lat.
Load Load B
270
340
440
630
730
890
1030
1620
2030
2460
3230
3880
4200
4840
5600
6130
6560
6890
9040
10540
11940
135
170
220
315
365
445
515
810
1015
1230
1615
1940
2100
2420
2800
3065
3280
3445
4520
5270
5970
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
1" Thk.
C
E
5
5
5.5
5.5
6
6.5
7
8.5
9.5
10
13
14.5
16.5
17.5
19
21
22.5
25.5
31.5
36
41.5
3.25
3.25
3.875
4.5
5
5.5
6.187
7.25
8.5
9.5
11.625
13.875
16.125
17.125
19.375
21.375
23.375
27.375
33.625
40.125
46.125
1 1/2" Thk.
C
E
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
6
6
6
5.5
5.5
6
6
6.5
8
8
9
10.5
11
13.5
15
17
18.5
19.5
21.5
23
26.5
32
37
42
4
4
4
4
4
4
4
4
4
4
4
4
4
4
6
6
6
6
6
6
6
4.375
4.375
5
5.5
6.0625
7.125
7.125
8.25
9.5
10.5
12.625
15.125
17.125
18.125
20.375
22.375
24.375
28.375
34.625
41.125
47.125
2" Thk.
C
E
6
6
6.5
7.5
7.5
8.5
8.5
10
11.5
12
14.5
16
18
19
20.5
22.5
23.5
27
33
37.5
43
5.375
5.375
6.062
7.125
7.125
8.125
8.125
9.25
10.5
11.625
13.625
16.125
18.125
19.125
21.375
23.375
25.375
29.375
35.625
42.125
48.125
2 1/2" Thk.
C
E
4
4
4
4
4
4
4
4
4
4
6
6
6
6
6
6
6
6
6
6
6
7.5
7.5
7.5
8
8
9.5
9.5
11
12.5
12.5
15
16.5
18.5
19.5
21
23
24.5
28
33.5
38
43.5
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
7
7
7
8.125
8.125
9.125
9.125
10.25
11.625
12.625
14.875
17.125
19.125
20.125
22.375
24.375
26.375
30.375
36.625
43.125
49.125
3" Thk.
C
E
8
8
8
9
9
10.5
10.5
12
13
13.5
16
17.5
19
20.5
22
23.5
25
28.5
34
39
44
8
8
8
9.125
9.125
10.125
10.125
11.375
12.625
13.625
15.875
18.125
20.125
21.125
23.375
25.375
27.375
31.375
37.625
44.125
50.125
B
6
6
6
6
6
6
6
6
6
6
6
6
6
6
8
8
8
8
8
8
8
4" Thk.
C
E
10
10
10
11
11
12
12
13.5
14.5
15
17.5
18.5
20.5
22
23
25
26.5
30
35.5
40.5
45.5
10
10
10
11.25
11.25
12.25
12.375
13.375
14.875
15.875
18.125
20.125
22.125
23.125
25.375
27.375
29.375
33.375
39.625
46.125
52.125
5" Thk.
C
E
B
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
11.5
11.5
11.5
12.5
12.5
13.5
13.5
15
16
16.5
18.5
20
22
23
24.5
26.5
28
31.5
37
42
47
The load ratings represent average values obtained in accordance with accepted methods and are subject to normal manufacturing variations.
---- Dimensions and ratings are subject to change without notice. ----
Easy Installation
Order Information: Specify Quantity Pipe Size & Type Insulation Thickness Figure Number
30
12.125
12.25
12.25
13.25
13.25
14.5
14.625
15.625
16.875
17.875
20.125
22.125
24.125
25.125
27.375
29.375
31.375
35.375
41.625
48.125
54.125
Fig. BP8282
Design Data
BP8282
Temperature Range
Range: +40F to +1200F
Higher temperatures available upon
request.
Insulation: Calcium Silicate asbestos
free, treated with water repellant.
Jackets: Galvanized Steel ASTM A-527.
Glue: Industrial contact adhesive.
Structural inserts: High-density
calcium silicate asbestos free, treated
with water repellant.
Steel Straps/Base: Carbon Steel
ASTM A-36.
Fasteners: ASTM A-307 plated.
Slide Pad: UHMW Polyethylene (Teflon
Optional).
Coating: Primer coated or hot dipped
galvanized. Other coatings available
upon request.
Note:
For higher load ratings, see BP8283
For lateral travel, see BP8262
Pipe
Size
1/2
3/4
1
1 1/2
2
2 1/2
3
4
5
6
8
10
12
14
16
18
20
24
30
36
42
Vert. Lat.
Load Load B
410
500
650
940
1090
1330
1540
2420
3040
3680
4840
5810
6300
7260
8390
9200
9840
10330
13550
15810
17910
205
250
325
470
545
665
770
1210
1520
1840
2420
2905
3150
3630
4195
4600
4920
5165
6775
7905
8955
1" Thk.
C
E
1 1/2" Thk.
C
E
2" Thk.
C
E
2 1/2" Thk.
C
E
4 5
3.25 4 5.5 4.375 4 6
5.375 4 7.5
7
6
4 5
3.25 4 5.5 4.375 4 6
5.375 4 7.5
7
6
4 5.5
4
4 6
5
4 6.5 6.062 4 7.5 7.125 6
4 6
4.5
4 6.5
5.5
4 8
7.125 4 8.5 8.125 6
4 7
5
4 7.5 6.1875 4 8.5 7.125 4 9
8.125 6
4 7
5.5
4 8.5 7.125 4 9
8.125 4 10 9.125 6
4 7.5 6.187 4 8.5 7.125 4 9
8.125 4 10 9.125 6
4 9.5
7.25 4 10
8.25 4 11
9.25 4 12 10.25 6
4 12.5
8.5
4 13
9.5
4 14.5 10.5 4 16 11.625 6
4 12
9.5
4 13.5 10.5 4 15 11.625 4 16 12.625 6
4 16 11.625 4 17 12.625 4 18.5 13.625 6 19 14.875 6
4 19 13.875 4 19.5 15.125 4 20.5 16.125 6 21 17.125 6
4 21 16.125 4 21.5 17.125 4 22.5 18.125 6 23.5 19.125 6
4 22 17.125 4 23 18.125 4 24 19.125 6 24.5 20.125 6
4 23.5 19.375 4 24 20.375 6 25 21.375 6 26 22.375 6
4 25.5 21.375 4 26.5 22.375 6 27.5 23.375 6 28 24.375 6
4 28 23.375 4 28.5 24.375 6 29 25.375 6 29.5 26.375 6
4 31 27.375 4 32 28.375 6 32.5 29.375 6 33 30.375 6
4 37 33.625 6 38 34.625 6 38.5 35.625 6 39.5 36.625 6
4 43 40.125 6 43.5 41.125 6 44.5 42.125 6 45.5 43.125 6
4 49 46.125 6 50 47.125 6 51 48.125 6 51.5 49.125 6
3" Thk.
C
E
8
8
8
9.5
10
11
11
13
17
17.5
20
22
24
25.5
27
28.5
30
34
40.5
46
52.5
8
8
8.125
9.125
9.125
10.125
10.125
11.375
12.625
13.625
15.875
18.125
20.125
21.125
23.375
25.375
27.375
31.375
37.625
44.125
50.125
B
6
6
6
6
6
6
6
6
6
6
6
6
6
6
8
8
8
8
8
8
8
4" Thk.
C
E
10
10
10
11.5
12
12.5
12.5
14.5
19
18.5
21.5
23.5
26
27.5
28
29.5
31.5
35.5
42
47.5
54
10
10
10.125
11.25
11.25
12.25
12.375
13.375
14.875
15.875
18.125
20.125
22.125
23.125
25.375
27.375
29.375
33.375
39.625
46.125
52.125
B
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
5" Thk.
C
E
11.5
11.5
11.5
13
13.5
14
14
16
20.5
20.5
23
25.5
27.5
28.5
29
31
33
37
43.5
49.5
55.5
12.125
12.25
12.25
13.25
13.25
14.5
14.625
15.625
16.875
17.875
20.125
22.125
24.125
25.125
27.375
29.375
31.375
35.375
41.625
48.125
54.125
The load ratings represent average values obtained in accordance with accepted methods and are subject to normal manufacturing variations.
---- Dimensions and ratings are subject to change without notice. ----
Easy Installation
Order Information: Specify Quantity Pipe Size & Type Insulation Thickness Figure Number
31
Fig. BP8283
BP8283
Design Data
Temperature Range
Range: +40F to +1200F
Higher temperatures available upon
request.
Insulation: Calcium Silicate asbestos
free, treated with water repellant.
Jackets: Galvanized Steel ASTM A-527.
Glue: Industrial contact adhesive.
Structural inserts: High-density
calcium silicate asbestos free, treated
with water repellant.
Steel Straps/Base: Carbon Steel
ASTM A-36.
Fasteners: ASTM A-307 plated.
Slide Pad: UHMW Polyethylene (Teflon
Optional).
Coating: Primer coated or hot dipped
galvanized. Other coatings available
upon request.
Note:
For lateral travel, see BP8263
Pipe
Size
1/2
3/4
1
1 1/2
2
2 1/2
3
4
5
6
8
10
12
14
16
18
20
24
30
36
42
Vert. Lat.
Load Load B
540
670
870
1250
1450
1770
2050
3230
4050
4910
6460
7750
8390
9680
11190
12260
13120
13770
18070
21080
23880
270
335
435
625
725
885
1025
1615
2025
2455
3230
3875
4195
4840
5595
6130
6560
6885
9035
10540
11940
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
1" Thk.
C
E
5
5
5.5
6
7
7
8
10
13
13
17
20
21.5
22.5
24.5
26.5
29
31.5
37.5
44
50
3.375
3.375
4
4.5
5
5.5
6.187
7.25
8.5
9.5
11.625
13.875
16.125
17.125
19.375
21.375
23.375
27.375
33.625
40.125
46.125
1 1/2" Thk.
C
E
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
6
6
6
5.5
5.5
6
6.5
7.5
8.5
9
10.5
13.5
14.5
18
20.5
22
23.5
25
27.5
29.5
32.5
38.5
44.5
51
4
4
4
4
4
4
4
4
4
4
4
4
4
4
6
6
6
6
6
6
6
4.5
4.5
5
5.5
6.0625
7.125
7.125
8.25
9.5
10.5
12.625
15.125
17.125
18.125
20.375
22.375
24.375
28.375
34.625
41.125
47.125
2" Thk.
C
E
6
6
6.5
8
8.5
9
9.5
11.5
15
16
19.5
21.5
23
24.5
26
28.5
30
33
39
45.5
52
5.5
5.5
6.062
7.125
7.125
8.125
8.125
9.25
10.5
11.625
13.625
16.125
18.125
19.125
21.375
23.375
25.375
29.375
35.625
42.125
48.125
2 1/2" Thk.
C
E
4
4
4
4
4
4
4
4
4
4
6
6
6
6
6
6
6
6
6
6
6
7.5
7.5
7.5
8.5
9
10
10.5
12.5
16.5
17
20
22
24
25
27
29
30.5
33.5
40
46.5
52.5
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
7.125
7.125
7.125
8.125
8.125
9.125
9.125
10.25
11.625
12.625
14.875
17.125
19.125
20.125
22.375
24.375
26.375
30.375
37.125
43.125
49.125
3" Thk.
C
E
8
8
8
9.5
10
11
11.5
13.5
17.5
18.5
21
23
24.5
26
28
29.5
31
34.5
41
47
53.5
8.125
8.125
8.125
9.125
9.125
10.125
10.125
11.375
12.625
13.625
15.875
18.125
20.125
21.125
23.375
25.375
27.375
31.375
38.125
44.125
50.125
B
6
6
6
6
6
6
6
6
6
6
6
6
6
6
8
8
8
8
8
8
8
4" Thk.
C
E
10
10
10
11.5
12
12.5
13
15
19.5
19.5
22.5
24.5
26.5
28
29
30.5
32.5
36
42.5
48.5
55
10.125
10.125
10.125
11.25
11.25
12.375
12.375
13.375
14.875
15.875
18.125
20.125
22.125
23.375
25.375
27.375
29.375
33.625
40.125
46.125
52.125
5" Thk.
C
E
B
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
11.5
11.5
11.5
13
13.5
14
14.5
16.5
21
21.5
24
26.5
28
29
30
32
34
37.5
44
50.5
56.5
The load ratings represent average values obtained in accordance with accepted methods and are subject to normal manufacturing variations.
---- Dimensions and ratings are subject to change without notice. ----
Easy Installation
Order Information: Specify Quantity Pipe Size & Type Insulation Thickness Figure Number
32
12.25
12.25
12.25
13.25
13.25
14.625
14.625
15.625
16.875
17.875
20.125
22.125
24.375
25.375
27.375
29.375
31.375
35.625
42.125
48.125
54.125
Section Contents
83-Series
Heavy Industrial Pipe Anchors
& Pre-Insulated Pipe Anchors
1-12
Fig.
BP8310
BP8311
BP8320
BP8321
BP8330
BP8331
BP8332
BP8333
BP8340
BP8341
BP8342
BP8343
Light
Light
Heavy
Heavy
Light
Medium
Heavy
X-Heavy
Light
Medium
Heavy
X-Heavy
1
2
3
4
5
6
7
8
9
10
11
12
83-Series
Page(s)
83-Series
83-Series
Fig.
Pipe
Size
Range
BP8310
3-6
No
Yes
Yes
Light
BP8311
3-6
No
Yes
No
Light
BP8320
8 - 30
No
Yes
No
Heavy
BP8321
8 - 30
No
Yes
No
Heavy
BP8330
BP8331
BP8332
BP8333
1/2 - 42
1/2 - 42
1/2 - 42
1/2 - 42
Yes
Yes
Yes
Yes
No
No
No
No
No
No
No
No
Light
Medium
Heavy
X-Heavy
5
6
7
8
BP8340
BP8341
BP8342
BP8343
1 - 42
1 - 42
1 - 42
1 - 42
Yes
Yes
Yes
Yes
Min.
Min.
Min.
Min.
No
No
No
No
Light
Medium
Heavy
X-Heavy
9
10
11
12
Order Information: Specify Quantity Pipe Size & Type Insulation Thickness Figure Number
A
Page
Fig. BP8310
Design Data
Material:
BP8310CS = Carbon Steel
BP8310CMS = Chrome-Moly Steel
BP8310CSS = Carbon Silicon Steel
BP8310SS = Stainless Steel
Coating: Primer coated or hot dipped
galvanized. Other coatings available
upon request.
BP8310
Note:
For no moment anchor, see BP8311.
For large bore welded anchor, see BP8320
For insulated friction anchor, see BP8330.
For insulated positive anchor, see BP8340
Pipe
Size
3
3.5
4
5
6
1"
B
3
3.5
4
5
6
1.75
2.25
2.75
3.5
4.5
0.56
0.56
0.56
0.69
0.69
4
4
4
4
4
2"
B
4
4
4
4
4
Insulation Thickness
3"
4"
5"
B
B
B
6
6
6
6
6
6
6
6
6
6
8
8
8
8
8
6"
B
7"
B
8
8
8
8
8
10
10
10
10
10
---- Dimensions and ratings are subject to change without notice. ----
Easy Installation
Order Information: Specify Quantity Pipe Size & Type Insulation Thickness Figure Number
Fig. BP8311
Design Data
Material:
BP8311CS = Carbon Steel
BP8311CMS = Chrome-Moly Steel
BP8311CSS = Carbon Silicon Steel
BP8311SS = Stainless Steel
Coating: Primer coated or hot dipped
galvanized. Other coatings available
upon request.
BP8311
Note:
For welded anchor, see BP8310.
For large bore no moment anchor, see
BP8321.
For insulated friction anchor, see BP8330.
For insulated positive anchor, see BP8340.
Pipe
Size
3
3.5
4
5
6
1"
B
2"
B
Insulation Thickness
3"
4"
5"
B
B
B
6"
B
7"
B
3
3.5
4
5
6
4
4
4
4
4
4
4
4
4
4
6
6
6
6
6
8
8
8
8
8
10
10
10
10
10
6
6
6
6
6
8
8
8
8
8
---- Dimensions and ratings are subject to change without notice. ----
Easy Installation
Order Information: Specify Quantity Pipe Size & Type Insulation Thickness Figure Number
2
Fig. BP8320
Design Data
Design Data
Material:
BP8320CS = Carbon Steel
BP8320CMS = Chrome-Moly Steel
BP8320CSS = Carbon Silicon Steel
BP8320SS = Stainless Steel
Coating: Primer coated or hot dipped
galvanized. Other coatings available
upon request.
BP8320
Note:
For no moment anchor, see BP8321.
For insulated friction anchor, see BP8330.
For insulated positive anchor, see BP8340.
Pipe
Size
8
10
12
14
16
18
20
24
30
1"
B
6
6
6
6
6
9
9
9
12
4
4
4
4
4
6.5
6.5
6.5
9
0.69
0.69
0.81
0.81
0.81
0.94
0.94
0.94
1.06
9
9
9
9
9
15
15
15
15
12
12
12
12
12
18
18
18
18
0.38
0.38
0.38
0.38
0.38
0.5
0.5
0.5
0.5
4
4
4
4
4
4
4
4
4
2"
B
4
4
4
4
6
6
6
6
6
Insulation Thickness
3"
4"
5"
B
B
B
6
6
6
6
6
6
6
6
6
6
6
6
6
8
8
8
8
8
8
8
8
8
8
8
8
8
8
6"
B
7"
B
8
8
8
8
10
10
10
10
10
10
10
10
10
10
10
10
10
10
---- Dimensions and ratings are subject to change without notice. ----
Easy Installation
Order Information: Specify Quantity Pipe Size & Type Insulation Thickness Figure Number
Fig. BP8321
Design Data
Material:
BP8321CS = Carbon Steel
BP8321CMS = Chrome-Moly Steel
BP8321CSS = Carbon Silicon Steel
BP8321SS = Stainless Steel
Coating: Primer coated or hot dipped
galvanized. Other coatings available
upon request.
BP8321
Note:
For welded anchor, see BP8320.
For insulated friction anchor, see BP8330.
For insulated positive anchor, see BP8340.
Pipe
Size
8
10
12
14
16
18
20
24
30
1"
B
6
6
6
6
6
9
9
9
12
4
4
4
4
4
6.5
6.5
6.5
9
0.69
0.69
0.81
0.81
0.81
0.94
0.94
0.94
1.06
9
9
9
9
9
15
15
15
15
12
12
12
12
12
18
18
18
18
0.38
0.38
0.38
0.38
0.38
0.5
0.5
0.5
0.5
4
4
4
4
4
4
4
4
4
2"
B
4
4
4
4
6
6
6
6
6
Insulation Thickness
3"
4"
5"
B
B
B
6
6
6
6
6
6
6
6
6
6
6
6
6
8
8
8
8
8
8
8
8
8
8
8
8
8
8
6"
B
7"
B
8
8
8
8
10
10
10
10
10
10
10
10
10
10
10
10
10
10
---- Dimensions and ratings are subject to change without notice. ----
Easy Installation
Order Information: Specify Quantity Pipe Size & Type Insulation Thickness Figure Number
4
Fig. BP8330
Design Data
BP8330
Temperature Range
Range: +40F to +1200F
Higher temperatures available upon
request.
Insulation: Calcium Silicate asbestos
free, treated with water repellant.
Jackets: Galvanized Steel ASTM A-527.
Glue: Industrial contact adhesive.
Structural inserts: High-density
calcium silicate asbestos free, treated
with water repellant.
Steel Straps/Base: Carbon Steel
ASTM A-36.
Fasteners: ASTM A-307 plated
Coating: Primer coated or hot dipped
galvanized. Other coatings available
upon request.
Note:
For higher load ratings, see BP8331,
BP8340-Series
1 1/2" Thk.
B
2" Thk.
B
4 2
4.375 4 2.5
4 2
4.375 4 2.5
4 2.5 4.875 4 3
4 2.5
5.5
4 4
4 3 6.0625 4 4
4 4
7.125 4 4.5
4 4
7.125 4 4.5
4 4.5
8.25 4 5.5
4 5.5
9.25 4 6.5
4 6.5 10.25 4 7.5
4 8 12.625 4 9
4 9.5 14.875 4 10.5
4 11 17.125 4 12
4 12 18.125 4 12.5
4 13 20.125 6 14
4 14.5 22.375 6 15.5
4 16 24.375 6 16.5
4 19 28.375 6 19.5
6 23 34.625 6 24
6 27.5 41.125 6 28
6 31.5 47.125 6 32.5
2 1/2" Thk.
3" Thk.
4" Thk.
5" Thk.
5.375
5.375
5.937
7
7
8.125
8.125
9.25
10.25
11.375
13.625
15.875
18.125
19.125
21.375
23.375
25.375
29.375
35.625
42.125
48.125
4
4
4
4
4
4
4
4
4
4
6
6
6
6
6
6
6
6
6
6
6
4
4
4
4.5
4.5
5.5
5.5
6.5
7.5
8
9.5
11
12.5
13
14.5
16
17.5
20.5
24.5
28.5
33
7
7
7
8
8
9.125
9.125
10.25
11.375
12.625
14.875
16.875
19.125
20.125
22.375
24.375
26.375
30.375
36.625
43.125
49.125
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
4.5
4.5
4.5
5.5
5.5
6.5
6.5
7.5
8
9
10.5
12
13
14
15.5
16.5
18
21
25
29.5
33.5
8
8
8
9
9.125
10.125
10.125
11.375
12.375
13.625
15.875
18.125
20.125
21.125
23.375
25.375
27.375
31.375
37.625
44.125
50.125
6
6
6
6
6
6
6
6
6
6
6
6
6
6
8
8
8
8
8
8
8
6.5
6.5
6.5
7.5
7.5
8
8
9
9.5
10.5
12
13
14.5
15.5
16.5
18
19.5
22.5
26.5
31
35
10
10
10
11.25
11.25
12.25
12.375
13.375
14.875
15.875
17.875
20.125
22.125
23.125
25.375
27.375
29.375
33.375
39.625
46.125
52.125
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
9
9
9.5
9.5
10.5
11
12
13
14.5
16
16.5
18
19.5
21
24
28
32.5
36.5
12.125
12.125
12.25
13.25
13.25
14.5
14.625
15.625
16.875
17.875
20.125
22.125
24.125
25.125
27.375
29.375
31.375
35.375
41.625
48.125
54.125
The load ratings represent average values obtained in accordance with accepted methods and are subject to normal manufacturing variations.
---- Dimensions and ratings are subject to change without notice. ----
Easy Installation
Order Information: Specify Quantity Pipe Size & Type Insulation Thickness Figure Number
Fig. BP8331
BP8331
Design Data
Temperature Range
Range: +40F to +1200F
Higher temperatures available upon
request.
Insulation: Calcium Silicate asbestos
free, treated with water repellant.
Jackets: Galvanized Steel ASTM A-527.
Glue: Industrial contact adhesive.
Structural inserts: High-density
calcium silicate asbestos free, treated
with water repellant.
Steel Straps/Base: Carbon Steel
ASTM A-36.
Fasteners: ASTM A-307 plated
Coating: Primer coated or hot dipped
galvanized. Other coatings available
upon request.
Note:
For higher load ratings, see BP8332,
BP8340-Series
1 1/2" Thk.
B
2" Thk.
B
4 2
4.375 4 2.5
4 2
4.375 4 2.5
4 2.5
5
4 3
4 2.5
5.5
4 4
4 3 6.0625 4 4
4 4
7.125 4 4.5
4 4
7.125 4 4.5
4 4.5
8.25 4 5.5
4 5.5
9.5
4 6.5
4 6.5
10.5 4 7.5
4 8 12.625 4 9
4 9.5 15.125 4 10.5
4 11 17.125 4 12
4 12 18.125 4 12.5
4 13 20.375 6 14
4 14.5 22.375 6 15.5
4 16 24.375 6 16.5
4 19 28.375 6 19.5
6 23 34.625 6 24
6 27.5 41.125 6 28
6 31.5 47.125 6 32.5
2 1/2" Thk.
3" Thk.
4" Thk.
5" Thk.
5.375
5.375
6.062
7.125
7.125
8.125
8.125
9.25
10.5
11.625
13.625
16.125
18.125
19.125
21.375
23.375
25.375
29.375
35.625
42.125
48.125
4
4
4
4
4
4
4
4
4
4
6
6
6
6
6
6
6
6
6
6
6
4
4
4
4.5
4.5
5.5
5.5
6.5
7.5
8
9.5
11
12.5
13
14.5
16
17.5
20.5
24.5
28.5
33
7
7
7
8.125
8.125
9.125
9.125
10.25
11.625
12.625
14.875
17.125
19.125
20.125
22.375
24.375
26.375
30.375
36.625
43.125
49.125
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
4.5
4.5
4.5
5.5
5.5
6.5
6.5
7.5
8
9
10.5
12
13
14
15.5
16.5
18
21
25
29.5
33.5
8
8
8
9.125
9.125
10.125
10.125
11.375
12.625
13.625
15.875
18.125
20.125
21.125
23.375
25.375
27.375
31.375
37.625
44.125
50.125
6
6
6
6
6
6
6
6
6
6
6
6
6
6
8
8
8
8
8
8
8
6.5
6.5
6.5
7.5
7.5
8
8
9
9.5
10.5
12
13
14.5
15.5
16.5
18
19.5
22.5
26.5
31
35
10
10
10
11.25
11.25
12.25
12.375
13.375
14.875
15.875
18.125
20.125
22.125
23.125
25.375
27.375
29.375
33.375
39.625
46.125
52.125
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
9
9
9.5
9.5
10.5
11
12
13
14.5
16
16.5
18
19.5
21
24
28
32.5
36.5
12.125
12.25
12.25
13.25
13.25
14.5
14.625
15.625
16.875
17.875
20.125
22.125
24.125
25.125
27.375
29.375
31.375
35.375
41.625
48.125
54.125
The load ratings represent average values obtained in accordance with accepted methods and are subject to normal manufacturing variations.
---- Dimensions and ratings are subject to change without notice. ----
Easy Installation
Order Information: Specify Quantity Pipe Size & Type Insulation Thickness Figure Number
6
Fig. BP8332
Design Data
BP8332
Temperature Range
Range: +40F to +1200F
Higher temperatures available upon
request.
Insulation: Calcium Silicate asbestos
free, treated with water repellant.
Jackets: Galvanized Steel ASTM A-527.
Glue: Industrial contact adhesive.
Structural inserts: High-density
calcium silicate asbestos free, treated
with water repellant.
Steel Straps/Base: Carbon Steel
ASTM A-36.
Fasteners: ASTM A-307 plated
Coating: Primer coated or hot dipped
galvanized. Other coatings available
upon request.
Note:
For higher load ratings, see BP8333,
BP8340-Series
1 1/2" Thk.
B
2" Thk.
B
4 2
4.375 4 2.5
4 2
4.375 4 2.5
4 2.5
5
4 3
4 2.5
5.5
4 4
4 3 6.1875 4 4
4 4
7.125 4 4.5
4 4
7.125 4 4.5
4 4.5
8.25 4 5.5
4 5.5
9.5
4 6.5
4 6.5
10.5 4 7.5
4 8 12.625 4 9
4 9.5 15.125 4 10.5
4 11 17.125 4 12
4 12 18.125 4 12.5
4 13 20.375 6 14
4 14.5 22.375 6 15.5
4 16 24.375 6 16.5
4 19 28.375 6 19.5
6 23 34.625 6 24
6 27.5 41.125 6 28
6 31.5 47.125 6 32.5
2 1/2" Thk.
3" Thk.
4" Thk.
5" Thk.
5.375
5.375
6.062
7.125
7.125
8.125
8.125
9.25
10.5
11.625
13.625
16.125
18.125
19.125
21.375
23.375
25.375
29.375
35.625
42.125
48.125
4
4
4
4
4
4
4
4
4
4
6
6
6
6
6
6
6
6
6
6
6
4
4
4
4.5
4.5
5.5
5.5
6.5
7.5
8
9.5
11
12.5
13
14.5
16
17.5
20.5
24.5
28.5
33
7
7
7.125
8.125
8.125
9.125
9.125
10.25
11.625
12.625
14.875
17.125
19.125
20.125
22.375
24.375
26.375
30.375
36.625
43.125
49.125
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
4.5
4.5
4.5
5.5
5.5
6.5
6.5
7.5
8
9
10.5
12
13
14
15.5
16.5
18
21
25
29.5
33.5
8
8
8.125
9.125
9.125
10.125
10.125
11.375
12.625
13.625
15.875
18.125
20.125
21.125
23.375
25.375
27.375
31.375
37.625
44.125
50.125
6
6
6
6
6
6
6
6
6
6
6
6
6
6
8
8
8
8
8
8
8
6.5
6.5
6.5
7.5
7.5
8
8
9
9.5
10.5
12
13
14.5
15.5
16.5
18
19.5
22.5
26.5
31
35
10
10
10.125
11.25
11.25
12.25
12.375
13.375
14.875
15.875
18.125
20.125
22.125
23.125
25.375
27.375
29.375
33.375
39.625
46.125
52.125
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
9
9
9.5
9.5
10.5
11
12
13
14.5
16
16.5
18
19.5
21
24
28
32.5
36.5
12.125
12.25
12.25
13.25
13.25
14.5
14.625
15.625
16.875
17.875
20.125
22.125
24.125
25.125
27.375
29.375
31.375
35.375
41.625
48.125
54.125
The load ratings represent average values obtained in accordance with accepted methods and are subject to normal manufacturing variations.
---- Dimensions and ratings are subject to change without notice. ----
Easy Installation
Order Information: Specify Quantity Pipe Size & Type Insulation Thickness Figure Number
Fig. BP8333
BP8333
Design Data
Temperature Range
Range: +40F to +1200F
Higher temperatures available upon
request.
Insulation: Calcium Silicate asbestos
free, treated with water repellant.
Jackets: Galvanized Steel ASTM A-527.
Glue: Industrial contact adhesive.
Structural inserts: High-density
calcium silicate asbestos free, treated
with water repellant.
Steel Straps/Base: Carbon Steel
ASTM A-36.
Fasteners: ASTM A-307 plated
Coating: Primer coated or hot dipped
galvanized. Other coatings available
upon request.
Note:
For higher load ratings, see
BP8340-Series
1 1/2" Thk.
B
2" Thk.
B
4 2
4.5
4 2.5
4 2
4.5
4 2.5
4 2.5
5
4 3
4 2.5
5.5
4 4
4 3 6.0625 4 4
4 4
7.125 4 4.5
4 4
7.125 4 4.5
4 4.5
8.25 4 5.5
4 5.5
9.5
4 6.5
4 6.5
10.5 4 7.5
4 8 12.625 4 9
4 9.5 15.125 4 10.5
4 11 17.125 4 12
4 12 18.125 4 12.5
4 13 20.375 6 14
4 14.5 22.375 6 15.5
4 16 24.375 6 16.5
4 19 28.375 6 19.5
6 23 34.625 6 24
6 27.5 41.125 6 28
6 31.5 47.125 6 32.5
2 1/2" Thk.
3" Thk.
4" Thk.
5" Thk.
5.5
5.5
6.062
7.125
7.125
8.125
8.125
9.25
10.5
11.625
13.625
16.125
18.125
19.125
21.375
23.375
25.375
29.375
35.625
42.125
48.125
4
4
4
4
4
4
4
4
4
4
6
6
6
6
6
6
6
6
6
6
6
4
4
4
4.5
4.5
5.5
5.5
6.5
7.5
8
9.5
11
12.5
13
14.5
16
17.5
20.5
24.5
28.5
33
7.125
7.125
7.125
8.125
8.125
9.125
9.125
10.25
11.625
12.625
14.875
17.125
19.125
20.125
22.375
24.375
26.375
30.375
36.625
43.125
49.125
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
4.5
4.5
4.5
5.5
5.5
6.5
6.5
7.5
8
9
10.5
12
13
14
15.5
16.5
18
21
25
29.5
33.5
8.125
8.125
8.125
9.125
9.125
10.125
10.125
11.375
12.625
13.625
15.875
18.125
20.125
21.125
23.375
25.375
27.375
31.375
37.625
44.125
50.125
6
6
6
6
6
6
6
6
6
6
6
6
6
6
8
8
8
8
8
8
8
6.5
6.5
6.5
7.5
7.5
8
8
9
9.5
10.5
12
13
14.5
15.5
16.5
18
19.5
22.5
26.5
31
35
10.125
10.125
10.125
11.25
11.25
12.375
12.375
13.375
14.875
15.875
18.125
20.125
22.125
23.125
25.375
27.375
29.375
33.375
39.625
46.125
52.125
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
9
9
9.5
9.5
10.5
11
12
13
14.5
16
16.5
18
19.5
21
24
28
32.5
36.5
12.25
12.25
12.25
13.25
13.25
14.625
14.625
15.625
16.875
17.875
20.125
22.125
24.125
25.125
27.375
29.375
31.375
35.375
41.625
48.125
54.125
The load ratings represent average values obtained in accordance with accepted methods and are subject to normal manufacturing variations.
---- Dimensions and ratings are subject to change without notice. ----
Easy Installation
Order Information: Specify Quantity Pipe Size & Type Insulation Thickness Figure Number
8
Fig. BP8340
Design Data
BP8340
Material:
BP8340CS = Carbon Steel
BP8340CMS = Chrome Moly Steel
BP8340CSS = Carbon Silicon Steel
BP8340SS = Stainless Steel
Temperature Range
Range: +40F to +1200F
Higher temperatures available upon
request.
Jackets: Galvanized Steel ASTM A-527.
Glue: Industrial contact adhesive.
Structural inserts: High-density
calcium silicate asbestos free, treated
with water repellant.
Steel Straps/Base: Carbon Steel
ASTM A-36.
Fasteners: ASTM A-307 plated
Coating: Primer coated or hot dipped
galvanized. Other coatings available
upon request.
Note:
For higher load ratings, see BP8341.
1" Thk.
B
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
C
2
2
2.5
2.5
3
4
4.5
5.5
7.5
9
10.5
11
12.5
14
15.5
18
22.5
26.5
31
D
0.1875
0.1875
0.1875
0.1875
0.1875
0.1875
0.1875
0.1875
0.1875
0.1875
0.1875
0.1875
0.1875
0.1875
0.1875
0.1875
0.1875
0.1875
0.1875
1 1/2" Thk.
E
4.125
4.625
5.125
5.625
6.187
7.25
8.25
9.25
11.375
13.625
15.625
16.625
18.625
20.625
22.625
26.625
33.125
39.125
45.125
B
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
6
6
6
C
2.5
2.5
3
4
4
4.5
5.5
6.5
8
9.5
11
12
13
14.5
16
19
23
27.5
31.5
D
0.1875
0.1875
0.1875
0.1875
0.25
0.25
0.25
0.25
0.25
0.25
0.25
0.25
0.25
0.25
0.25
0.25
0.25
0.25
0.25
2" Thk.
E
5.125
5.625
6.1875
7.25
7.25
8.25
9.25
10.25
12.375
14.875
16.875
17.875
19.875
21.875
23.875
27.875
34.125
40.125
46.125
B
4
4
4
4
4
4
4
4
4
4
4
4
6
6
6
6
6
6
6
C
3
4
4
4.5
4.5
5.5
6.5
7.5
9
10.5
12
12.5
14
15.5
16.5
19.5
24
28
32.5
D
0.25
0.25
0.25
0.25
0.25
0.25
0.25
0.25
0.25
0.25
0.25
0.25
0.25
0.25
0.25
0.25
0.25
0.25
0.25
2 1/2" Thk.
E
6.187
7.25
7.25
8.25
8.25
9.25
10.25
11.375
13.375
15.875
17.875
18.875
20.875
22.875
24.875
28.875
35.125
41.125
47.125
B
4
4
4
4
4
4
4
4
6
6
6
6
6
6
6
6
6
6
6
C
4
4.5
4.5
5.5
5.5
6.5
7.5
8
9.5
11
12.5
13
14.5
16
17.5
20.5
24.5
28.5
33
D
0.25
0.25
0.25
0.25
0.3125
0.3125
0.3125
0.3125
0.3125
0.3125
0.3125
0.3125
0.3125
0.3125
0.3125
0.3125
0.3125
0.3125
0.3125
3" Thk.
E
7.25
8.25
8.25
9.25
9.25
10.25
11.375
12.375
14.625
16.875
18.875
19.875
21.875
23.875
25.875
29.875
36.125
42.125
48.125
B
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
C
4.5
5.5
5.5
6.5
6.5
7.5
8
9
10.5
12
13
14
15.5
16.5
18
21
25
29.5
33.5
D
0.25
0.25
0.25
0.25
0.3125
0.3125
0.3125
0.3125
0.3125
0.3125
0.3125
0.3125
0.3125
0.3125
0.3125
0.3125
0.3125
0.3125
0.3125
4" Thk.
E
8.25
9.25
9.25
10.25
10.25
11.375
12.375
13.375
15.625
17.875
19.875
20.875
22.875
24.875
26.875
30.875
37.125
43.125
49.125
B
6
6
6
6
6
6
6
6
6
6
6
6
8
8
8
8
8
8
8
C
6.5
7.5
7.5
8
8
9
9.5
10.5
12
13
14.5
15.5
16.5
18
19.5
22.5
26.5
31
35
D
0.25
0.25
0.3125
0.3125
0.375
0.375
0.375
0.375
0.375
0.375
0.375
0.375
0.375
0.375
0.375
0.375
0.375
0.375
0.375
E
10.25
11.375
11.375
12.375
12.375
13.375
14.625
15.625
17.625
19.875
21.875
22.875
24.875
26.875
28.875
32.875
39.125
45.125
51.125
The load ratings represent average values obtained in accordance with accepted methods and are subject to normal manufacturing variations.
---- Dimensions and ratings are subject to change without notice. ----
Easy Installation
Order Information: Specify Quantity Pipe Size & Type Insulation Thickness Figure Number
Fig. BP8341
BP8341
Design Data
Material:
BP8341CS = Carbon Steel
BP8341CMS = Chrome Moly Steel
BP8341CSS = Carbon Silicon Steel
BP8341SS = Stainless Steel
Temperature Range
Range: +40F to +1200F
Higher temperatures available upon
request.
Jackets: Galvanized Steel ASTM A-527.
Glue: Industrial contact adhesive.
Structural inserts: High-density
calcium silicate asbestos free, treated
with water repellant.
Steel Straps/Base: Carbon Steel
ASTM A-36.
Fasteners: ASTM A-307 plated
Coating: Primer coated or hot dipped
galvanized. Other coatings available
upon request.
Note:
For higher load ratings, see BP8342.
1 1/2" Thk.
B C
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
6
6
6
2.5
2.5
3
4
4
4.5
5.5
6.5
8
9.5
11
12
13
14.5
16
19
23
27.5
31.5
2" Thk.
0.25
0.25
0.25
0.25
0.3125
0.3125
0.3125
0.3125
0.3125
0.3125
0.3125
0.3125
0.3125
0.3125
0.3125
0.3125
0.3125
0.3125
0.3125
5.375
5.875
6.4375
7.5
7.5
8.5
9.5
10.5
12.625
15.125
17.125
18.125
20.125
22.125
24.125
28.125
34.375
40.375
46.375
B C
4
4
4
4
4
4
4
4
4
4
4
4
6
6
6
6
6
6
6
3
4
4
4.5
4.5
5.5
6.5
7.5
9
10.5
12
12.5
14
15.5
16.5
19.5
24
28
32.5
2 1/2" Thk.
0.25
0.25
0.25
0.25
0.3125
0.3125
0.3125
0.3125
0.3125
0.3125
0.3125
0.3125
0.3125
0.3125
0.3125
0.3125
0.3125
0.3125
0.3125
6.437
7.5
7.5
8.5
8.5
9.5
10.5
11.625
13.625
16.125
18.125
19.125
21.125
23.125
25.125
29.125
35.375
41.375
47.375
B C
4
4
4
4
4
4
4
4
6
6
6
6
6
6
6
6
6
6
6
3" Thk.
E
B C
4" Thk.
E
B C
The load ratings represent average values obtained in accordance with accepted methods and are subject to normal manufacturing variations.
---- Dimensions and ratings are subject to change without notice. ----
Easy Installation
Order Information: Specify Quantity Pipe Size & Type Insulation Thickness Figure Number
10
4
0.25
7.5 6 4.5 0.25
8.5 6 6.5 0.3125 10.5
4.5 0.3125 8.5 6 5.5 0.3125 9.5 6 7.5 0.3125 11.625
4.5 0.3125 8.5 6 5.5 0.3125 9.5 6 7.5 0.3125 11.625
5.5 0.3125 9.5 6 6.5 0.3125 10.5 6 8
0.375 12.625
5.5 0.375
9.5 6 6.5 0.375 10.5 6 8
0.5 12.625
6.5 0.375 10.5 6 7.5 0.375 11.625 6 9
0.5 13.625
7.5 0.375 11.625 6 8
0.375 12.625 6 9.5
0.5 14.875
8
0.375 12.625 6 9
0.375 13.625 6 10.5 0.5 15.875
9.5 0.375 14.875 6 10.5 0.375 15.875 6 12
0.5 17.875
11 0.375 17.125 6 12 0.375 18.125 6 13
0.5 20.125
12.5 0.375 19.125 6 13 0.375 20.125 6 14.5 0.5 22.125
13 0.375 20.125 6 14 0.375 21.125 6 15.5 0.5 23.125
14.5 0.375 22.125 6 15.5 0.375 23.125 8 16.5 0.5 25.125
16 0.375 24.125 6 16.5 0.375 25.125 8 18
0.5 27.125
17.5 0.375 26.125 6 18 0.375 27.125 8 19.5 0.5 29.125
20.5 0.375 30.125 6 21 0.375 31.125 8 22.5 0.5 33.125
24.5 0.375 36.375 6 25 0.375 37.375 8 26.5 0.5 39.375
28.5 0.375 42.375 6 29.5 0.375 43.375 8 31
0.5 45.375
33 0.375 48.375 6 33.5 0.375 49.375 8 35
0.5 51.375
Fig. BP8342
Design Data
BP8342
Material:
BP8342CS = Carbon Steel
BP8342CMS = Chrome Moly Steel
BP8342CSS = Carbon Silicon Steel
BP8342SS = Stainless Steel
Temperature Range
Range: +40F to +1200F
Higher temperatures available upon
request.
Jackets: Galvanized Steel ASTM A-527.
Glue: Industrial contact adhesive.
Structural inserts: High-density
calcium silicate asbestos free, treated
with water repellant.
Steel Straps/Base: Carbon Steel
ASTM A-36.
Fasteners: ASTM A-307 plated
Coating: Primer coated or hot dipped
galvanized. Other coatings available
upon request.
Note:
For higher load ratings, see BP8343.
Pipe
Size
1
1 1/2
2
2 1/2
3
4
5
6
8
10
12
14
16
18
20
24
30
36
42
Load Rating
Vert.
Lbs
Axial
Lbs B
650
940
1180
1410
1730
2690
3340
4090
5490
6460
7100
8070
9360
10330
10970
11620
15170
17750
17750
970
1390
1750
2110
3710
4410
5110
5810
7180
8610
10000
10760
12160
13450
14840
17530
21620
25700
25700
4
4
4
4
4
4
4
4
4
4
4
4
6
6
6
6
6
6
6
2" Thk.
2 1/2" Thk.
3" Thk.
4" Thk.
3
4
4
4.5
4.5
5.5
6.5
7.5
9
10.5
12
12.5
14
15.5
16.5
19.5
24
28
32.5
0.3125
0.3125
0.3125
0.3125
0.375
0.375
0.375
0.375
0.375
0.375
0.375
0.375
0.375
0.375
0.375
0.375
0.375
0.375
0.375
6.687
7.75
7.75
8.75
8.75
9.75
10.75
11.875
13.875
16.375
18.375
19.375
21.375
23.375
25.375
29.375
35.625
41.625
47.625
4
4
4
4
4
4
4
4
6
6
6
6
6
6
6
6
6
6
6
4
4.5
4.5
5.5
5.5
6.5
7.5
8
9.5
11
12.5
13
14.5
16
17.5
20.5
24.5
28.5
33
0.3125
0.3125
0.3125
0.375
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5
7.75
8.75
8.75
9.75
9.75
10.75
11.875
12.875
15.125
17.375
19.375
20.375
22.375
24.375
26.375
30.375
36.625
42.625
48.625
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
4.5
5.5
5.5
6.5
6.5
7.5
8
9
10.5
12
13
14
15.5
16.5
18
21
25
29.5
33.5
0.3125
0.375
0.375
0.375
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5
8.75
9.75
9.75
10.75
10.75
11.875
12.875
13.875
16.125
18.375
20.375
21.375
23.375
25.375
27.375
31.375
37.625
43.625
49.625
6
6
6
6
6
6
6
6
6
6
6
6
8
8
8
8
8
8
8
6.5
7.5
7.5
8
8
9
9.5
10.5
12
13
14.5
15.5
16.5
18
19.5
22.5
26.5
31
35
0.3125
0.375
0.375
0.375
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5
10.75
11.875
11.875
12.875
12.875
13.875
15.125
16.125
18.125
20.375
22.375
23.375
25.375
27.375
29.375
33.375
39.625
45.625
51.625
The load ratings represent average values obtained in accordance with accepted methods and are subject to normal manufacturing variations.
---- Dimensions and ratings are subject to change without notice. ----
Easy Installation
Order Information: Specify Quantity Pipe Size & Type Insulation Thickness Figure Number
11
Fig. BP8343
BP8343
Design Data
Material:
BP8343CS = Carbon Steel
BP8343CMS = Chrome Moly Steel
BP8343CSS = Carbon Silicon Steel
BP8343SS = Stainless Steel
Temperature Range
Range: +40F to +1200F
Higher temperatures available upon
request.
Jackets: Galvanized Steel ASTM A-527.
Glue: Industrial contact adhesive
Structural inserts: High-density
calcium silicate asbestos free, treated
with water repellant.
Steel Straps/Base: Carbon Steel
ASTM A-36.
Fasteners: ASTM A-307 plated
Coating: Primer coated or hot dipped
galvanized. Other coatings available
upon request.
Pipe
Size
1
1 1/2
2
2 1/2
3
4
5
6
8
10
12
14
16
18
20
24
30
36
42
Load Rating
2 1/2" Thk.
3" Thk.
4" Thk.
Vert.
Lbs
Axial
Lbs
980
1410
1770
2130
2610
3350
4130
4920
6400
7980
9470
10760
12480
13770
14630
15490
20220
23660
26670
1470
2120
2650
3210
3900
5020
6200
7380
9610
11970
14200
16130
18710
20650
21940
23230
30330
35490
40000
4
4
4
4
4
4
4
4
6
6
6
6
6
6
6
6
6
6
6
4
4.5
4.5
5.5
5.5
6.5
7.5
8
9.5
11
12.5
13
14.5
16
17.5
20.5
24.5
28.5
33
0.375
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5
8
9
9
10
10
11
12.125
13.125
15.375
17.375
19.625
20.625
22.625
24.625
26.625
30.625
37.125
43.125
49.125
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
4.5
5.5
5.5
6.5
6.5
7.5
8
9
10.5
12
13
14
15.5
16.5
18
21
25
29.5
33.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.625
0.625
0.625
0.625
0.625
0.625
0.625
0.625
0.625
0.625
0.625
0.625
9
10
10
11
11
12.125
13.125
14.125
16.375
18.375
20.625
21.625
23.625
25.625
27.625
31.625
38.125
44.125
50.125
6
6
6
6
6
6
6
6
6
6
6
6
8
8
8
8
8
8
8
6.5
7.5
7.5
8
8
9
9.5
10.5
12
13
14.5
15.5
16.5
18
19.5
22.5
26.5
31
35
0.5
0.5
0.5
0.625
0.625
0.625
0.625
0.625
0.625
0.625
0.625
0.625
0.625
0.625
0.625
0.625
0.625
0.625
0.625
11
12.125
12.125
13.125
13.125
14.125
15.375
16.375
18.375
20.375
22.625
23.625
25.625
27.625
29.625
33.625
40.125
46.125
52.125
The load ratings represent average values obtained in accordance with accepted methods and are subject to normal manufacturing variations.
---- Dimensions and ratings are subject to change without notice. ----
Easy Installation
Order Information: Specify Quantity Pipe Size & Type Insulation Thickness Figure Number
12
Section Contents
84-Series
Light & Heavy Industrial
Two-Bolt and Two-Rod Hangers
1-12
Fig.
BP8410
BP8420
BP8430
BP8431
BP8432
BP8433
BP8440
BP8450
BP8460
BP8461
BP8462
BP8463
Light
Light
Light
Medium
Heavy
X-Heavy
Light
Light
Light
Medium
Heavy
X-Heavy
1
2
3
4
5
6
7
8
9
10
11
12
84-Series
Page(s)
84-Series
84-Series
Fig.
Pipe
Size
Range
Load
Class
Page
BP8410
BP8420
BP8430
BP8431
BP8432
BP8433
1/2 - 4
1/2 - 4
1 - 42
1 - 42
1 - 42
1 - 42
Light
Light
Light
Medium
Heavy
X-Heavy
1
2
3
4
5
6
BP8440
BP8450
BP8460
BP8461
BP8462
BP8463
1/2 - 4
1/2 - 4
5 - 30
5 - 30
16 - 30
20 - 30
Light
Light
Light
Medium
Heavy
X-Heavy
7
8
9
10
11
12
Order Information: Specify Quantity Pipe Size & Type Insulation Thickness Figure Number
A
Fig. BP8410
Design Data
Temperature Range: +40F to +1200F
Higher temperatures available upon
request.
Insulation: Calcium Silicate asbestos
free, treated with water repellant.
Jackets: Galvanized Steel ASTM A-527.
Steel Straps: Carbon Steel ASTM A-36.
Glue: Industrial contact adhesive.
Coating: Primer coated or hot dip
galvanized. Other coatings available
upon request.
Fasteners: ASTM A-307 plated.
Load Rating:
For process systems operating at
500 F or greater, multiply the load rating
in the chart by the following factors:
500 = .90, 750 = .75, 1000 = .50,
1200 = .30
For higher load ratings, see BP8430.
Pipe
Size
1/2
3/4
1
1 1/2
2
2 1/2
3
4
1" Thk.
2" Thk.
3" Thk.
4" Thk.
5" Thk.
Vert. Load
70
90
100
170
270
320
400
520
1/8x 1 1/2
1/8x 1 1/2
1/8x 1 1/2
1/8x 1 1/2
1/4x 1 1/2
1/4x 1 1/2
1/4x 1 1/2
1/4x 1 1/2
0.38
0.38
0.38
0.38
0.50
0.50
0.63
0.63
0.69
0.69
0.69
0.69
0.81
0.81
1.06
1.06
0.56
0.56
0.56
0.56
0.63
0.63
0.63
0.63
2.38
2.38
2.69
2.94
3.56
3.81
4.22
4.75
4
4
4
4
6
6
6
6
3.44
3.44
3.72
4.25
4.63
5.13
5.25
5.75
4
4
4
4
6
6
6
6
4.75
4.75
4.75
5.25
5.63
6.13
6.25
6.81
6
6
6
6
6
9
9
9
5.75
5.75
5.75
6.31
6.69
7.19
7.31
7.81
6
6
6
6
6
9
9
9
6.81
6.81
6.81
7.31
7.69
8.31
8.44
8.94
6
6
6
6
6
9
9
9
BP8410
The load ratings represent average values obtained in accordance with accepted methods and are subject to normal manufacturing variations.
---- Dimensions and ratings are subject to change without notice. ----
Easy Installation
Order Information: Specify Quantity Pipe Size & Type Insulation Thickness Figure Number
Fig. BP8420
Design Data
Temperature Range: +40F to +1200F
Higher temperatures available upon
request.
Insulation: Calcium Silicate asbestos
free, treated with water repellant.
Jackets: Galvanized Steel ASTM A-527.
Steel Straps: Carbon Steel ASTM A-36.
Glue: Industrial contact adhesive.
Coating: Primer coated or hot dip
galvanized. Other coatings available
upon request.
Fasteners: ASTM A-307 plated.
Load Rating:
For process systems operating at
500 F or greater, multiply the load rating
in the chart by the following factors:
500 = .90, 750 = .75, 1000 = .50,
1200 = .30
For higher load ratings, see BP8430.
BP8420
Pipe
Size
1/2
3/4
1
1 1/2
2
2 1/2
3
4
1" Thk.
2" Thk.
3" Thk.
4" Thk.
5" Thk.
Vert. Load
70
90
100
170
270
320
400
520
1/8x 1 1/2
1/8x 1 1/2
1/8x 1 1/2
1/8x 1 1/2
1/4x 1 1/2
1/4x 1 1/2
1/4x 1 1/2
1/4x 1 1/2
0.375
0.375
0.375
0.375
0.50
0.50
0.625
0.625
0.6875
0.6875
0.6875
0.6875
0.8125
0.8125
1.0625
1.0625
0.563
0.563
0.563
0.563
0.625
0.625
0.625
0.625
2.38
2.38
2.69
2.94
3.56
3.81
4.22
4.75
6
6
6
6
6
6
6
6
3.44
3.44
3.72
4.25
4.63
5.13
5.25
5.75
6
6
6
6
6
6
6
6
4.75
4.75
4.75
5.25
5.63
6.13
6.25
6.81
6
6
6
6
6
9
9
9
5.75
5.75
5.75
6.31
6.69
7.19
7.31
7.81
6
6
6
6
6
9
9
9
6.81
6.81
6.81
7.31
7.69
8.31
8.44
8.94
6
6
6
6
6
9
9
9
The load ratings represent average values obtained in accordance with accepted methods and are subject to normal manufacturing variations.
---- Dimensions and ratings are subject to change without notice. ----
Easy Installation
Order Information: Specify Quantity Pipe Size & Type Insulation Thickness Figure Number
2
Fig. BP8430
Design Data
Temperature Range: +40F to +1200F
Higher temperatures available upon
request.
Insulation: Calcium Silicate asbestos
free, treated with water repellant.
Structural inserts: High-density
calcium silicate asbestos free, treated
with water repellant.
Jackets: Galvanized Steel ASTM A-527.
Steel Straps: Carbon Steel ASTM A-36.
Glue: Industrial contact adhesive.
Coating: Primer coated or hot dip
galvanized. Other coatings available
upon request.
Fasteners: ASTM A-307 plated.
Note:
For higher load ratings, see BP8431.
Pipe
Size
1
1 1/2
2
2 1/2
3
4
5
6
8
10
12
14
16
18
20
24
30
36
42
1" Thk.
2" Thk.
3" Thk.
4" Thk.
5" Thk.
Vert. Load
310
350
350
590
590
830
1210
1540
1950
2490
2910
2910
3270
4040
4150
5310
5700
8450
8570
3/16x2
3/16x2
3/16x2
1/4x2
1/4x2
1/4x3
3/8x3
3/8x3
1/2x3
1/2x3
5/8x3
5/8x3
5/8x3
3/4x3
3/4x3
1x3
1x3
1x6
1x6
0.375
0.375
0.375
0.375
0.375
0.5
0.5
0.625
0.625
0.75
0.75
0.75
0.875
0.875
1
1
1.25
1.25
1.25
0.68
0.68
0.68
0.68
0.68
0.84
0.84
1.05
1.05
1.05
1.05
1.05
1.32
1.32
1.32
1.32
1.66
1.66
1.66
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
1
1
1
1
1.25
1.25
1.25
2.81
3.06
3.31
3.69
3.97
4.63
5.38
6
7.31
8.44
9.69
10.19
11.31
12.56
13.69
16.19
19.44
22.44
25.44
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
9
9
3.84
4.38
4.38
5
5
5.63
6.38
7.06
8.31
9.56
10.69
11.19
12.31
13.56
14.69
17.19
20.44
23.44
26.44
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
9
9
4.88
5.38
5.38
6
6
6.69
7.44
8.06
9.44
10.56
11.69
12.18
13.31
14.56
15.69
18.19
21.44
24.44
27.44
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
9
9
5.88
6.44
6.44
7.06
7.06
7.69
8.56
9.18
10.44
11.56
12.69
13.19
14.31
15.56
16.69
19.18
22.44
25.44
28.44
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
9
9
6.94
7.44
7.44
8.19
8.19
8.81
9.56
10.19
11.44
12.56
13.69
14.19
15.31
16.56
17.69
20.19
23.44
26.44
29.44
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
9
9
BP8430
The load ratings represent average values obtained in accordance with accepted methods and are subject to normal manufacturing variations.
---- Dimensions and ratings are subject to change without notice. ----
Easy Installation
Order Information: Specify Quantity Pipe Size & Type Insulation Thickness Figure Number
Fig. BP8431
Design Data
Temperature Range: +40F to +1200F
Higher temperatures available upon
request.
Insulation: Calcium Silicate asbestos
free, treated with water repellant.
Structural inserts: High-density
calcium silicate asbestos free, treated
with water repellant.
Jackets: Galvanized Steel ASTM A-527.
Steel Straps: Carbon Steel ASTM A-36.
Glue: Industrial contact adhesive.
Coating: Primer coated or hot dip
galvanized. Other coatings available
upon request.
Fasteners: ASTM A-307 plated.
Note:
For higher load ratings, see BP8432.
BP8431
Pipe
Size
1
1 1/2
2
2 1/2
3
4
5
6
8
10
12
14
16
18
20
24
30
36
42
1" Thk.
2" Thk.
3" Thk.
4" Thk.
5" Thk.
Vert. Load
550
660
660
880
1210
1850
2520
2910
3880
3910
5020
5020
7340
7340
8570
11060
11400
14000
14000
3/16x3
1/4x3
1/4x3
1/4x3
3/8x3
3/8x3
1/2x3
1/2x3
5/8x3
5/8x3
3/4x3
3/4x3
3/4x5
3/4x5
1x6
1x6
1x6
1 1/4x6
1 1/4x6
0.38
0.38
0.38
0.5
0.5
0.63
0.75
0.75
0.88
0.88
1
1
1.25
1.25
1.25
1.5
1.5
2
2
0.675
0.675
0.675
0.84
0.84
1.05
1.05
1.05
1.315
1.315
1.315
1.315
1.66
1.66
1.66
1.9
1.9
2.375
2.375
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
1
1
1
1
1.25
1.25
1.25
1.25
1.25
1.75
1.75
2.81
3.19
3.44
3.81
4.34
5
5.88
6.38
7.69
8.69
10.19
10.69
11.94
12.94
14.44
16.69
19.69
23.69
26.69
6
6
6
6
6
6
6
6
6
6
6
6
9
9
9
9
9
9
9
3.84
4.5
4.5
5.13
5.38
6
6.88
7.44
8.69
9.81
11.19
11.69
12.94
13.94
15.44
17.69
20.69
24.69
27.69
6
6
6
6
6
6
6
6
6
6
6
6
9
9
9
9
9
9
9
4.88
5.5
5.5
6.13
6.38
7.06
7.94
8.44
9.81
10.81
12.19
12.69
13.94
14.94
16.44
18.69
21.69
25.69
28.69
6
6
6
6
6
6
6
6
6
6
6
6
9
9
9
9
9
9
9
5.88
6.56
6.56
7.19
7.44
8.06
9.06
9.56
10.81
11.81
13.19
13.69
14.94
15.94
17.44
19.69
22.69
26.69
29.69
6
6
6
6
6
6
6
6
6
6
6
6
9
9
9
9
9
9
9
6.94
7.56
7.56
8.31
8.56
9.19
10.06
10.56
11.81
12.81
14.19
14.69
15.94
16.94
18.44
20.69
23.69
27.69
30.69
6
6
6
6
6
6
6
6
6
6
6
6
9
9
9
9
9
9
9
The load ratings represent average values obtained in accordance with accepted methods and are subject to normal manufacturing variations.
---- Dimensions and ratings are subject to change without notice. ----
Easy Installation
Order Information: Specify Quantity Pipe Size & Type Insulation Thickness Figure Number
4
Fig. BP8432
Design Data
Temperature Range: +40F to +1200F
Higher temperatures available upon
request.
Insulation: Calcium Silicate asbestos
free, treated with water repellant.
Structural inserts: High-density
calcium silicate asbestos free, treated
with water repellant.
Jackets: Galvanized Steel ASTM A-527.
Steel Straps: Carbon Steel ASTM A-36.
Glue: Industrial contact adhesive.
Coating: Primer coated or hot dip
galvanized. Other coatings available
upon request.
Fasteners: ASTM A-307 plated.
Note:
For higher load ratings, see BP8433.
Pipe
Size
1
1 1/2
2
2 1/2
3
4
5
6
8
10
12
14
16
18
20
24
30
36
42
Vert. Load
920
1310
1310
1310
1950
2780
2910
4040
4540
6500
8360
8360
8570
12120
12330
13140
17730
18680
18680
1/4x4 1/2
1/4x4 1/2
1/4x4 1/2
1/4x4 1/2
3/8x4 1/2
3/8x4 1/2
1/2x4 1/2
1/2x4 1/2
1/2x5
5/8x5
3/4x5
3/4x5
1x5
1x5
1x6
1x6
1 1/4x6
1 1/4x8
1 1/4x8
0.63
0.63
0.63
0.63
0.63
0.75
0.75
0.88
1
1.25
1.25
1.25
1.25
1.5
1.5
2
2
2
2
1.05
1.05
1.05
1.05
1.05
1.05
1.05
1.32
1.32
1.66
1.66
1.66
1.66
1.9
1.9
2.375
2.375
2.375
2.375
0.75
0.75
0.75
0.75
0.75
0.75
0.75
1
1
1.25
1.25
1.25
1.25
1.25
1.25
1.75
1.75
1.75
1.75
1" Thk.
2" Thk.
3" Thk.
4" Thk.
5" Thk.
BP8432
The load ratings represent average values obtained in accordance with accepted methods and are subject to normal manufacturing variations.
---- Dimensions and ratings are subject to change without notice. ----
Easy Installation
Order Information: Specify Quantity Pipe Size & Type Insulation Thickness Figure Number
Fig. BP8433
Design Data
Temperature Range: +40F to +1200F
Higher temperatures available upon
request.
Insulation: Calcium Silicate asbestos
free, treated with water repellant.
Structural inserts: High-density
calcium silicate asbestos free, treated
with water repellant.
Jackets: Galvanized Steel ASTM A-527.
Steel Straps: Carbon Steel ASTM A-36.
Glue: Industrial contact adhesive.
Coating: Primer coated or hot dip
galvanized. Other coatings available
upon request.
Fasteners: ASTM A-307 plated.
BP8433
Pipe
Size
1
1.5
2
2.5
3
4
5
6
8
10
12
14
16
18
20
24
30
36
42
1" Thk.
2" Thk.
3" Thk.
4" Thk.
5" Thk.
Vert. Load
1230
1760
1850
1950
2910
3710
4040
5310
7760
7810
10030
10030
12330
15540
17830
20440
22160
26780
26780
1/4x6
1/4x6
1/4x6
3/8x6
3/8x6
3/8x6
1/2x6
1/2x6
5/8x6
5/8x6
3/4x6
3/4x6
1x6
1x6
1 1/4x6
1 1/4x6
1 1/4x8
1 1/2x8
1 1/2x8
0.63
0.63
0.63
0.63
0.75
0.875
0.88
1
1.25
1.25
1.5
1.5
1.5
2
2
2
2
2.5
2.5
1.05
1.05
1.05
1.05
1.05
1.315
1.32
1.32
1.66
1.66
1.9
1.9
1.9
2.375
2.375
2.375
2.375
3.508
3.508
0.75
0.75
0.75
0.75
0.75
1
1
1
1.25
1.25
1.25
1.25
1.25
1.75
1.75
1.75
1.75
1.75
1.75
3.188
3.44
3.69
4.19
4.59
5.25
6
6.75
8.06
9.06
10.69
11.19
12.69
14.06
15.69
17.69
20.69
24.44
27.44
9
9
9
9
9
9
9
9
9
9
9
9
9
9
9
9
12
12
12
4.22
4.75
4.75
5.5
5.63
6.25
7
7.81
9.06
10.19
11.69
12.19
13.69
15.06
16.69
18.69
21.69
25.44
28.44
9
9
9
9
9
9
9
9
9
9
9
9
9
9
9
9
12
12
12
5.25
5.75
5.75
6.5
6.63
7.31
8.06
8.81
10.19
11.19
12.69
13.19
14.69
16.06
17.69
19.69
22.69
26.44
29.44
9
9
9
9
9
9
9
9
9
9
9
9
9
9
9
9
12
12
12
6.25
6.81
6.81
7.56
7.69
8.31
9.19
9.94
11.19
12.19
13.69
14.19
15.69
17.06
18.69
20.69
23.69
27.44
30.44
9
9
9
9
9
9
9
9
9
9
9
9
9
9
9
9
12
12
12
7.31
7.81
7.81
8.69
8.81
9.44
10.19
10.94
12.19
13.19
14.69
15.19
16.69
18.06
19.69
21.69
24.69
28.44
31.44
9
9
9
9
9
9
9
9
9
9
9
9
9
9
9
9
12
12
12
The load ratings represent average values obtained in accordance with accepted methods and are subject to normal manufacturing variations.
---- Dimensions and ratings are subject to change without notice. ----
Easy Installation
Order Information: Specify Quantity Pipe Size & Type Insulation Thickness Figure Number
6
Fig. BP8440
Design Data
Temperature Range: +40F to +1200F
Higher temperatures available upon
request.
Insulation: Calcium Silicate asbestos
free, treated with water repellant.
Jackets: Galvanized Steel ASTM A-527.
Steel Straps: Carbon Steel ASTM A-36.
Glue: Industrial contact adhesive.
Coating: Primer coated or hot dip
galvanized. Other coatings available
upon request.
Fasteners: ASTM A-307 plated.
Load Rating:
For process systems operating at
500 F or greater, multiply the load rating
in the chart by the following factors:
500 = .90, 750 = .75, 1000 = .50,
1200 = .30
For higher load ratings, see BP8460.
Pipe
Size
1/2
3/4
1
1 1/2
2
2 1/2
3
4
1" Thk.
3" Thk.
2" Thk.
4" Thk.
Vert. Load
70
90
100
140
270
320
400
520
1/8x1 1/2
1/8x1 1/2
1/8x1 1/2
1/8x1 1/2
1/4x1 1/2
1/4x1 1/2
1/4x1 1/2
1/4x1 1/2
0.375
0.375
0.375
0.375
0.375
0.375
0.375
0.375
1.63
1.63
1.94
2.19
2.44
2.69
2.97
3.5
4.75
4.75
5.375
5.875
6.875
7.375
7.937
9
6
6
6
6
6
6
6
6
2.69
2.69
2.97
3.50
3.50
4.0
4.0
4.5
6.875
6.875
7.437
8.5
9
10
10
11
6
6
6
6
6
6
6
6
4.0
4.0
4.0
4.5
4.5
5.0
5.0
5.56
9.5
9.5
9.5
10.5
11
12
12
13.13
6
6
6
6
6
9
9
9
5.0
5.0
5.0
5.56
5.56
6.06
6.06
6.56
11.5
11.5
11.5
12.63
13.13
14.13
14.13
15.13
6
6
6
6
6
9
9
9
BP8440
The load ratings represent average values obtained in accordance with accepted methods and are subject to normal manufacturing variations.
---- Dimensions and ratings are subject to change without notice. ----
Easy Installation
Order Information: Specify Quantity Pipe Size & Type Insulation Thickness Figure Number
Fig. BP8450
Design Data
Temperature Range: +40F to +1200F
Higher temperatures available upon
request.
Insulation: Calcium Silicate asbestos
free, treated with water repellant.
Jackets: Galvanized Steel ASTM A-527.
Steel Straps: Carbon Steel ASTM A-36.
Glue: Industrial contact adhesive.
Coating: Primer coated or hot dip
galvanized. Other coatings available
upon request.
Fasteners: ASTM A-307 plated.
Load Rating:
For process systems operating at
500F or greater, multiply the load rating
in the chart by the following factors:
500 = .90, 750 = .75, 1000 = .50,
1200 = .30
For higher load ratings, see BP8460.
BP8450
Pipe
Size
1/2
3/4
1
1 1/2
2
2 1/2
3
4
1" Thk.
3" Thk.
2" Thk.
4" Thk.
Vert. Load
70
90
100
140
270
320
400
520
1/8x1 1/2
1/8x1 1/2
1/8x1 1/2
1/8x1 1/2
1/4x1 1/2
1/4x1 1/2
1/4x1 1/2
1/4x1 1/2
0.375
0.375
0.375
0.375
0.375
0.375
0.375
0.375
1.63
1.63
1.94
2.19
2.44
2.69
2.97
3.5
4.75
4.75
5.375
5.875
6.875
7.375
7.937
9
6
6
6
6
6
6
6
6
2.69
2.69
2.97
3.50
3.50
4.0
4.0
4.5
6.875
6.875
7.437
8.5
9
10
10
11
6
6
6
6
6
6
6
6
4.0
4.0
4.0
4.5
4.5
5.0
5.0
5.56
9.5
9.5
9.5
10.5
11
12
12
13.13
6
6
6
6
6
9
9
9
5.0
5.0
5.0
5.56
5.56
6.06
6.06
6.56
11.5
11.5
11.5
12.63
13.13
14.13
14.13
15.13
6
6
6
6
6
9
9
9
The load ratings represent average values obtained in accordance with accepted methods and are subject to normal manufacturing variations.
---- Dimensions and ratings are subject to change without notice. ----
Easy Installation
Order Information: Specify Quantity Pipe Size & Type Insulation Thickness Figure Number
8
Fig. BP8460
Design Data
Temperature Range: +40F to +1200F
Higher temperatures available upon
request.
Insulation: Calcium Silicate asbestos
free, treated with water repellant.
Structural inserts: High-density
calcium silicate asbestos free, treated
with water repellant.
Jackets: Galvanized Steel ASTM A-527.
Steel Straps: Carbon Steel ASTM A-36.
Glue: Industrial contact adhesive.
Coating: Primer coated or hot dip
galvanized. Other coatings available
upon request.
Fasteners: ASTM A-307 plated.
Note:
For higher load ratings, see BP8461.
Pipe
Size
5
6
8
10
12
14
16
18
20
24
30
1" Thk.
2" Thk.
3" Thk.
4" Thk.
Vert. Load
650
870
1400
2160
2590
2690
3550
3770
3880
4840
5170
1/2x3
1/2x3
1/2x3
1/2x3
5/8x3
5/8x3
3/4x3
3/4x3
3/4x3
1x3
1x3
0.375
0.375
0.500
0.500
0.625
0.625
0.750
0.750
0.750
0.750
0.750
4.13
4.63
5.68
6.69
7.81
8.31
9.31
10.31
11.31
13.31
16.31
11
12
14.38
16.38
19.38
20.38
22.88
24.88
26.88
31.63
37.63
6
6
6
6
6
6
6
9
9
9
12
5.13
5.68
6.68
7.81
8.81
9.31
10.31
11.31
12.31
14.31
17.31
13
14.13
16.38
18.63
21.38
22.38
24.88
26.88
28.88
33.63
39.63
6
6
6
6
6
6
9
9
9
12
12
6.18
6.68
7.81
8.81
9.81
10.31
11.31
12.31
13.31
15.31
18.31
15.13
16.13
18.63
20.63
23.38
24.38
26.88
28.88
30.88
35.63
41.63
6
6
6
6
6
9
9
9
9
12
12
7.31
7.81
8.81
9.81
10.81
11.31
12.31
13.31
14.31
16.31
19.31
17.38
18.38
20.63
22.63
25.38
26.38
28.88
30.88
32.88
37.63
43.63
6
6
6
9
9
9
9
12
12
12
12
BP8460
The load ratings represent average values obtained in accordance with accepted methods and are subject to normal manufacturing variations.
---- Dimensions and ratings are subject to change without notice. ----
Easy Installation
Order Information: Specify Quantity Pipe Size & Type Insulation Thickness Figure Number
Fig. BP8461
Design Data
Temperature Range: +40F to +1200F
Higher temperatures available upon
request.
Insulation: Calcium Silicate asbestos
free, treated with water repellant.
Structural inserts: High-density
calcium silicate asbestos free, treated
with water repellant.
Jackets: Galvanized Steel ASTM A-527.
Steel Straps: Carbon Steel ASTM A-36.
Glue: Industrial contact adhesive.
Coating: Primer coated or hot dip
galvanized. Other coatings available
upon request.
Fasteners: ASTM A-307 plated.
Note:
For higher load ratings, see BP8462.
BP8461
Pipe
Size
5
6
8
10
12
14
16
18
20
24
30
1" Thk.
2" Thk.
3" Thk.
4" Thk.
Vert. Load
1300
1730
2800
4310
5170
5380
7100
7530
7750
9680
10330
1/2x3
1/2x3
1/2x3
5/8x3
3/4x3
3/4x3
1x3
1x4 1/2
1x4 1/2
1x4 1/2
1x4 1/2
0.50
0.50
0.63
0.75
0.75
0.75
0.88
0.88
0.88
1.00
1.25
4.13
4.63
5.68
6.69
7.81
8.31
9.31
10.31
11.31
13.31
16.31
11.25
12.25
14.63
17.13
19.88
20.88
24.13
26.13
28.13
32.38
38.88
6
6
6
6
6
6
6
9
9
9
12
5.13
5.68
6.68
7.81
8.81
9.31
10.31
11.31
12.31
14.31
17.31
13.25
14.38
16.63
19.38
21.88
22.88
26.13
28.13
30.13
34.38
40.88
6
6
6
6
6
6
9
9
9
12
12
6.18
6.68
7.81
8.81
9.81
10.31
11.31
12.31
13.31
15.31
18.31
15.38
16.38
18.88
21.38
23.88
24.88
28.13
30.13
32.13
36.38
42.88
6
6
6
6
6
9
9
9
9
12
12
7.31
7.81
8.81
9.81
10.81
11.31
12.31
13.31
14.31
16.31
19.31
17.63
18.63
20.88
23.38
25.88
26.88
30.13
32.13
34.13
38.38
44.88
6
6
6
9
9
9
9
9
12
12
12
The load ratings represent average values obtained in accordance with accepted methods and are subject to normal manufacturing variations.
---- Dimensions and ratings are subject to change without notice. ----
Easy Installation
Order Information: Specify Quantity Pipe Size & Type Insulation Thickness Figure Number
10
Fig. BP8462
Design Data
Temperature Range: +40F to +1200F
Higher temperatures available upon
request.
Insulation: Calcium Silicate asbestos
free, treated with water repellant.
Structural inserts: High-density
calcium silicate asbestos free, treated
with water repellant.
Jackets: Galvanized Steel ASTM A-527.
Steel Straps: Carbon Steel ASTM A-36.
Glue: Industrial contact adhesive.
Coating: Primer coated or hot dip
galvanized. Other coatings available
upon request.
Fasteners: ASTM A-307 plated.
Note:
For higher load ratings, see BP8463.
Pipe
Size Vert. Load
6620
16
18
6620
20
6620
24
9200
30
9200
1" Thk.
2" Thk.
3" Thk.
4" Thk.
1x4 1/2
1x4 1/2
1x4 1/2
1x4 1/2
1x4 1/2
1.25
1.25
1.25
1.25
1.25
9.31
10.31
11.31
13.31
16.31
24.88
26.88
28.88
32.88
38.88
6
9
9
9
12
10.31
11.31
12.31
14.31
17.31
26.88
28.88
30.88
34.88
40.88
9
9
9
12
12
11.31
12.31
13.31
15.31
18.31
28.88
30.88
32.88
36.88
42.88
9
9
9
12
12
12.31
13.31
14.31
16.31
19.31
30.88
32.88
34.88
38.88
44.88
9
9
12
12
12
BP8462
The load ratings represent average values obtained in accordance with accepted methods and are subject to normal manufacturing variations.
---- Dimensions and ratings are subject to change without notice. ----
Easy Installation
Order Information: Specify Quantity Pipe Size & Type Insulation Thickness Figure Number
11
Fig. BP8463
Design Data
Temperature Range: +40F to +1200F
Higher temperatures available upon
request.
Insulation: Calcium Silicate asbestos
free, treated with water repellant.
Structural inserts: High-density
calcium silicate asbestos free, treated
with water repellant.
Jackets: Galvanized Steel ASTM A-527.
Steel Straps: Carbon Steel ASTM A-36.
Glue: Industrial contact adhesive.
Coating: Primer coated or hot dip
galvanized. Other coatings available
upon request.
Fasteners: ASTM A-307 plated.
BP8463
Pipe
Size Vert. Load Bolt Torq ft-lbs
20
8820
50
24
12260
50
30
12260
50
1" Thk.
A
1x6
1x6
1x6
2" Thk.
E
9
9
12
12.31 30.88
14.31 35.38
17.31 41.38
3" Thk.
E
9
12
12
13.31 32.88
15.31 37.38
18.31 43.38
4" Thk.
E
9
12
12
14.31 34.88
16.31 39.38
19.31 45.38
E
12
12
12
The load ratings represent average values obtained in accordance with accepted methods and are subject to normal manufacturing variations.
---- Dimensions and ratings are subject to change without notice. ----
Easy Installation
Order Information: Specify Quantity Pipe Size & Type Insulation Thickness Figure Number
12
Section Contents
85-Series
Heavy Industrial Riser Clamps
Page(s)
Pictorial Selection Guide
1-8
Fig.
BP8510
BP8511
BP8512
BP8513
BP8520
BP8521
BP8522
BP8523
Light
Medium
Heavy
X-Heavy
Light
Medium
Heavy
X-Heavy
1
2
3
4
5
6
7
8
85-Series
85-Series
85-Series
Fig.
Pipe
Size
Range
Primary
Application
BP8510
BP8511
BP8512
BP8513
2 - 24
2 - 24
2 - 24
12 - 24
BP8520
BP8521
BP8522
BP8523
2 - 24
2 - 24
2 - 24
12 - 24
Load
Class
Page
DOWN
DOWN
DOWN
DOWN
Light
Medium
Heavy
X-Heavy
1
2
3
4
DOWN/UP
DOWN/UP
DOWN/UP
DOWN/UP
Light
Medium
Heavy
X-Heavy
5
6
7
8
Order Information: Specify Quantity Pipe Size & Type Insulation Thickness Figure Number
A
Fig. BP8510
Design Data
Material:
BP8510 = Carbon Steel
BP8510CMS = Chrome Moly Steel
BP8510CSS = Carbon Silicon Steel
BP8510SS = Stainless Steel
Temperature Range
Range: +40F to +1200F
Higher temperatures available upon
request.
Jackets: Galvanized Steel ASTM A-527.
Glue: Industrial contact adhesive.
Structural inserts: High-density
calcium silicate asbestos free, treated
with water repellant.
Steel Straps: Carbon Steel ASTM A-36.
Fasteners: ASTM A-307 plated.
Coating: Primer coated or hot dipped
galvanized. Other coatings available
upon request.
Note:
For higher load ratings, see BP8511.
For loads in up and downward direction,
see BP8520-Series.
Load
lbs
270
330
440
650
870
1080
1400
1730
1830
2160
2480
2690
2910
3020
0.63
0.63
0.63
0.63
0.63
0.63
0.63
0.63
0.63
0.88
0.88
0.88
0.88
0.88
0.25
0.25
0.25
0.25
0.25
0.25
0.25
0.38
0.38
0.38
0.38
0.38
0.38
0.38
0.25 x 3.00
0.25 x 3.00
0.25 x 3.00
0.25 x 3.00
0.25 x 3.00
0.25 x 4.00
0.25 x 4.00
0.38 x 5.00
0.38 x 5.00
0.38 x 5.00
0.38 x 5.00
0.38 x 5.00
0.38 x 5.00
0.38 x 5.00
1.50
1.50
1.50
1.50
1.50
2.00
2.00
3.00
3.00
3.00
3.00
3.00
3.00
3.00
0.625
0.625
0.625
0.625
0.625
0.625
0.625
0.625
0.625
0.625
0.625
0.625
0.625
0.625
1" Thk.
F
G
H
3.69
3.94
4.22
4.75
5.25
5.75
6.81
8.06
9.19
9.69
10.69
11.69
12.69
14.69
5.69
5.94
6.22
6.75
7.25
7.75
8.81
10.31
11.44
11.94
12.94
13.94
14.94
17.19
5.13
5.63
6.19
7.25
8.25
9.25
11.38
13.63
15.88
16.88
18.88
20.88
22.88
26.88
2" Thk.
F
G
H
4.75
5.25
5.25
5.75
6.25
6.81
7.81
9.19
10.19
10.69
11.69
12.69
13.69
15.69
6.75
7.25
7.25
7.75
8.25
8.81
9.81
11.44
12.44
12.94
13.94
14.94
15.94
18.19
7.25
8.25
8.25
9.25
10.25
11.38
13.38
15.88
17.88
18.88
20.88
22.88
24.88
28.88
3" Thk.
F
G
H
5.75
6.25
6.25
6.81
7.31
7.81
8.94
10.19
11.19
11.69
12.69
13.69
14.69
16.69
7.75
8.25
8.25
8.81
9.31
9.81
10.94
12.44
13.44
13.94
14.94
15.94
16.94
19.19
9.25
10.25
10.25
11.38
12.38
13.38
15.63
17.88
19.88
20.88
22.88
24.88
26.88
30.88
4" Thk.
F
G
H
6.81
7.31
7.31
7.81
8.44
8.94
9.94
11.19
12.19
12.69
13.69
14.69
15.69
17.69
8.81
9.31
9.31
9.81
10.44
10.94
11.94
13.44
14.44
14.94
15.94
16.94
17.94
20.19
11.38
12.38
12.38
13.38
14.63
15.63
17.63
19.88
21.88
22.88
24.88
26.88
28.88
32.88
BP8510
Pipe
Size
2
2 1/2
3
4
5
6
8
10
12
14
16
18
20
24
The load ratings represent average values obtained in accordance with accepted methods and are subject to normal manufacturing variations.
---- Dimensions and ratings are subject to change without notice. ----
Easy Installation
Order Information: Specify Quantity Pipe Size & Type Insulation Thickness Figure Number
Fig. BP8511
Design Data
Material:
BP8511 = Carbon Steel
BP8511CMS = Chrome Moly Steel
BP8511CSS = Carbon Silicon Steel
BP8511SS = Stainless Steel
Temperature Range
Range: +40F to +1200F
Higher temperatures available upon
request.
Jackets: Galvanized Steel ASTM A-527.
Glue: Industrial contact adhesive.
Structural inserts: High-density
calcium silicate asbestos free, treated
with water repellant.
Steel Straps: Carbon Steel ASTM A-36.
Fasteners: ASTM A-307 plated.
Coating: Primer coated or hot dipped
galvanized. Other coatings available
upon request.
Note:
For higher load ratings, see BP8512.
For loads in up and downward direction,
see BP8520-Series.
BP8511
Pipe
Size
2
2 1/2
3
4
5
6
8
10
12
14
16
18
20
24
Bolt
Load Torq
lbs ft - lbs
540
650
870
1300
1730
2160
2800
3450
3660
4310
4950
5380
5810
6030
5
5
10
10
15
15
20
30
30
40
40
50
50
60
0.63
0.63
0.63
0.63
0.63
0.63
0.63
0.88
0.88
0.88
0.88
0.88
0.88
0.88
0.38
0.38
0.38
0.38
0.38
0.38
0.50
0.50
0.50
0.50
0.50
0.50
0.50
0.50
0.38 x 3.00
0.38 x 3.00
0.38 x 3.00
0.38 x 3.00
0.38 x 4.00
0.38 x 4.00
0.50 x 4.00
0.50 x 5.00
0.50 x 5.00
0.50 x 5.00
0.50 x 6.00
0.50 x 6.00
0.50 x 6.00
0.50 x 6.00
1.50
1.50
1.50
1.50
2.00
2.00
2.00
3.00
3.00
3.00
4.00
4.00
4.00
4.00
0.625
0.625
0.625
0.625
0.625
0.625
0.625
0.625
0.625
0.75
0.75
0.75
0.75
0.75
6.19
6.44
6.72
7.25
7.75
8.25
9.81
10.81
11.94
12.69
13.69
14.69
15.69
17.69
5.38
5.88
6.44
7.50
8.50
9.50
11.88
13.88
16.13
17.13
19.13
21.13
23.13
27.13
7.25
7.75
7.75
8.25
8.75
9.31
10.81
11.94
12.94
13.69
14.69
15.69
16.69
18.69
7.50
8.50
8.50
9.50
10.50
11.63
13.88
16.13
18.13
19.13
21.13
23.13
25.13
29.13
8.25
8.75
8.75
9.31
9.81
10.31
11.94
12.94
13.94
14.69
15.69
16.69
17.69
19.69
9.50
10.50
10.50
11.63
12.63
13.63
16.13
18.13
20.13
21.13
23.13
25.13
27.13
31.13
9.31
9.81
9.81
10.31
10.94
11.44
12.94
13.94
14.94
15.69
16.69
17.69
18.69
20.69
The load ratings represent average values obtained in accordance with accepted methods and are subject to normal manufacturing variations.
---- Dimensions and ratings are subject to change without notice. ----
Easy Installation
Order Information: Specify Quantity Pipe Size & Type Insulation Thickness Figure Number
2
11.63
12.63
12.63
13.63
14.88
15.88
18.13
20.13
22.13
23.13
25.13
27.13
29.13
33.13
Fig. BP8512
Design Data
Material:
BP8512 = Carbon Steel
BP8512CMS = Chrome Moly Steel
BP8512CSS = Carbon Silicon Steel
BP8512SS = Stainless Steel
Temperature Range
Range: +40F to +1200F
Higher temperatures available upon
request.
Jackets: Galvanized Steel ASTM A-527.
Glue: Industrial contact adhesive.
Structural inserts: High-density
calcium silicate asbestos free, treated
with water repellant.
Steel Straps: Carbon Steel ASTM A-36.
Fasteners: ASTM A-307 plated.
Coating: Primer coated or hot dipped
galvanized. Other coatings available
upon request.
Note:
For higher load ratings, see BP8513.
For loads in up and downward direction,
see BP8520-series.
Bolt
Load Torq
lbs ft - lbs
810
970
1300
1940
2590
3230
4200
5170
5490
6460
7420
8070
8710
9040
10
10
15
15
20
25
30
45
45
60
60
75
75
90
0.63
0.63
0.63
0.63
0.63
0.88
0.88
0.88
1.13
1.13
1.13
1.13
1.13
1.13
0.50
0.50
0.50
0.50
0.50
0.50
0.50
0.50
0.50
0.50
0.50
0.50
0.50
0.50
0.50 x 3.00
0.50 x 3.00
0.50 x 3.00
0.50 x 4.00
0.50 x 4.00
0.50 x 5.00
0.50 x 5.00
0.50 x 6.00
0.50 x 6.00
0.50 x 6.00
0.50 x 7.00
0.50 x 7.00
0.50 x 7.00
0.50 x 7.00
1.50
1.50
1.50
2.00
2.00
3.00
3.00
4.00
4.00
4.00
5.00
5.00
5.00
5.00
0.625
0.625
0.625
0.625
0.625
0.625
0.625
0.75
0.75
0.75
0.88
0.88
0.88
0.88
6.19
6.44
6.72
7.25
7.75
8.25
9.31
10.69
11.81
12.31
13.44
14.44
15.44
17.69
5.63
6.13
6.69
7.75
8.75
9.75
11.88
13.88
16.13
17.13
19.13
21.13
23.13
27.13
7.25
7.75
7.75
8.25
8.75
9.31
10.31
11.81
12.81
13.31
14.44
15.44
16.44
18.69
7.75
8.75
8.75
9.75
10.75
11.88
13.88
16.13
18.13
19.13
21.13
23.13
25.13
29.13
8.25
8.75
8.75
9.31
9.81
10.31
11.44
12.81
13.81
14.31
15.44
16.44
17.44
19.69
9.75
10.75
10.75
11.88
12.88
13.88
16.13
18.13
20.13
21.13
23.13
25.13
27.13
31.13
9.31
9.81
9.81
10.31
10.94
11.44
12.44
13.81
14.81
15.31
16.44
17.44
18.44
20.69
11.88
12.88
12.88
13.88
15.13
16.13
18.13
20.13
22.13
23.13
25.13
27.13
29.13
33.13
BP8512
Pipe
Size
2
2 1/2
3
4
5
6
8
10
12
14
16
18
20
24
The load ratings represent average values obtained in accordance with accepted methods and are subject to normal manufacturing variations.
---- Dimensions and ratings are subject to change without notice. ----
Easy Installation
Order Information: Specify Quantity Pipe Size & Type Insulation Thickness Figure Number
Fig. BP8513
Design Data
Material:
BP8513 = Carbon Steel
BP8513CMS = Chrome Moly Steel
BP8513CSS = Carbon Silicon Steel
BP8513SS = Stainless Steel
Temperature Range
Range: +40F to +1200F
Higher temperatures available upon
request.
Jackets: Galvanized Steel ASTM A-527.
Glue: Industrial contact adhesive.
Structural inserts: High-density
calcium silicate asbestos free, treated
with water repellant.
Steel Straps: Carbon Steel ASTM A-36.
Fasteners: ASTM A-307 plated.
Coating: Primer coated or hot dipped
galvanized. Other coatings available
upon request.
Note:
For loads in up and downward direction,
see BP8520-Series.
BP8513
Pipe
Size
12
14
16
18
20
24
Bolt
Load Torq
lbs ft - lbs
7320
8610
9900
10760
11620
12050
60
75
90
100
100
120
1.13
1.13
1.13
1.13
1.13
1.13
0.50
0.50
0.63
0.63
0.63
0.63
0.50 x 7.00
0.50 x 7.00
0.63 x 7.00
0.63 x 7.00
0.63 x 7.00
0.63 x 7.00
5.00
5.00
5.00
5.00
5.00
5.00
0.875
0.875
1.00
1.00
1.00
1.25
9.69
10.19
11.44
12.44
13.44
15.69
11.94
12.44
13.69
14.69
15.69
18.19
16.13
17.13
19.38
21.38
23.38
27.38
12.94
13.44
14.69
15.69
16.69
19.19
18.13
19.13
21.38
23.38
25.38
29.38
13.94
14.44
15.69
16.69
17.69
20.19
20.13
21.13
23.38
25.38
27.38
31.38
14.94
15.44
16.69
17.69
18.69
21.19
The load ratings represent average values obtained in accordance with accepted methods and are subject to normal manufacturing variations.
---- Dimensions and ratings are subject to change without notice. ----
Easy Installation
Order Information: Specify Quantity Pipe Size & Type Insulation Thickness Figure Number
4
22.13
23.13
25.38
27.38
29.38
33.38
Fig. BP8520
Design Data
Material:
BP8520 = Carbon Steel
BP8520CMS = Chrome Moly Steel
BP8520CSS = Carbon Silicon Steel
BP8520SS = Stainless Steel
Temperature Range
Range: +40F to +1200F
Higher temperatures available upon
request.
Jackets: Galvanized Steel ASTM A-527.
Glue: Industrial contact adhesive.
Structural inserts: High-density
calcium silicate asbestos free, treated
with water repellant.
Steel Straps: Carbon Steel ASTM A-36.
Fasteners: ASTM A-307 plated.
Coating: Primer coated or hot dipped
galvanized. Other coatings available
upon request.
Note:
For higher load ratings, see BP8521.
For loads in the downward direction
only, see BP8510-Series.
Load
lbs
270
330
440
650
870
1080
1400
1730
1830
2160
2480
2690
2910
3020
0.625
0.625
0.625
0.625
0.625
0.625
0.625
0.625
0.625
0.875
0.875
0.875
0.875
0.875
0.25
0.25
0.25
0.25
0.25
0.25
0.25
0.375
0.375
0.375
0.375
0.375
0.375
0.375
0.25 x 3.00
0.25 x 3.00
0.25 x 3.00
0.25 x 3.00
0.25 x 3.00
0.25 x 4.00
0.25 x 4.00
0.38 x 5.00
0.38 x 5.00
0.38 x 5.00
0.38 x 5.00
0.38 x 5.00
0.38 x 5.00
0.38 x 5.00
1.50
1.50
1.50
1.50
1.50
2.00
2.00
3.00
3.00
3.00
3.00
3.00
3.00
3.00
0.625
0.625
0.625
0.625
0.625
0.625
0.625
0.625
0.625
0.625
0.625
0.625
0.625
0.625
5.69
5.94
6.22
6.75
7.25
7.75
8.81
10.31
11.44
11.94
12.94
13.94
14.94
17.19
5.13
5.63
6.19
7.25
8.25
9.25
11.38
13.63
15.88
16.88
18.88
20.88
22.88
26.88
6.75
7.25
7.25
7.75
8.25
8.81
9.81
11.44
12.44
12.94
13.94
14.94
15.94
18.19
7.25
8.25
8.25
9.25
10.25
11.38
13.38
15.88
17.88
18.88
20.88
22.88
24.88
28.88
7.75
8.25
8.25
8.81
9.31
9.81
10.94
12.44
13.44
13.94
14.94
15.94
16.94
19.19
9.25
10.25
10.25
11.38
12.38
13.38
15.63
17.88
19.88
20.88
22.88
24.88
26.88
30.88
8.81
9.31
9.31
9.81
10.44
10.94
11.94
13.44
14.44
14.94
15.94
16.94
17.94
20.19
11.38
12.38
12.38
13.38
14.63
15.63
17.63
19.88
21.88
22.88
24.88
26.88
28.88
32.88
BP8520
Pipe
Size
2
2 1/2
3
4
5
6
8
10
12
14
16
18
20
24
The load ratings represent average values obtained in accordance with accepted methods and are subject to normal manufacturing variations.
---- Dimensions and ratings are subject to change without notice. ----
Easy Installation
Order Information: Specify Quantity Pipe Size & Type Insulation Thickness Figure Number
Fig. BP8521
Design Data
Material:
BP8521 = Carbon Steel
BP8521CMS = Chrome Moly Steel
BP8521CSS = Carbon Silicon Steel
BP8521SS = Stainless Steel
Temperature Range
Range: +40F to +1200F
Higher temperatures available upon
request.
Jackets: Galvanized Steel ASTM A-527.
Glue: Industrial contact adhesive.
Structural inserts: High-density
calcium silicate asbestos free, treated
with water repellant.
Steel Straps: Carbon Steel ASTM A-36.
Fasteners: ASTM A-307 plated.
Coating: Primer coated or hot dipped
galvanized. Other coatings available
upon request.
Note:
For higher load ratings, see BP8522.
For loads in the downward direction
only, see BP8510-Series.
BP8521
Pipe
Size
2
2 1/2
3
4
5
6
8
10
12
14
16
18
20
24
Load
lbs
540
650
870
1300
1730
2160
2800
3450
3660
4310
4950
5380
5810
6030
0.625
0.625
0.625
0.625
0.625
0.625
0.625
0.875
0.875
0.875
0.875
0.875
0.875
0.875
0.375
0.375
0.375
0.375
0.375
0.375
0.50
0.50
0.50
0.50
0.50
0.50
0.50
0.50
0.38 x 3.00
0.38 x 3.00
0.38 x 3.00
0.38 x 3.00
0.38 x 4.00
0.38 x 4.00
0.50 x 4.00
0.50 x 5.00
0.50 x 5.00
0.50 x 5.00
0.50 x 6.00
0.50 x 6.00
0.50 x 6.00
0.50 x 6.00
1.50
1.50
1.50
1.50
2.00
2.00
2.00
3.00
3.00
3.00
4.00
4.00
4.00
4.00
0.63
0.63
0.63
0.63
0.63
0.63
0.63
0.63
0.63
0.75
0.75
0.75
0.75
0.75
6.19
6.44
6.72
7.25
7.75
8.25
9.81
10.81
11.94
12.69
13.69
14.69
15.69
17.69
5.38
5.88
6.44
7.5
8.5
9.5
11.88
13.88
16.13
17.13
19.13
21.13
23.13
27.13
7.25
7.75
7.75
8.25
8.75
9.31
10.81
11.94
12.94
13.69
14.69
15.69
16.69
18.69
7.5
8.5
8.5
9.5
10.5
11.63
13.88
16.13
18.13
19.13
21.13
23.13
25.13
29.13
8.25
8.75
8.75
9.31
9.81
10.31
11.94
12.94
13.94
14.69
15.69
16.69
17.69
19.69
9.5
10.5
10.5
11.63
12.63
13.63
16.13
18.13
20.13
21.13
23.13
25.13
27.13
31.13
9.31
9.81
9.81
10.31
10.94
11.44
12.94
13.94
14.94
15.69
16.69
17.69
18.69
20.69
The load ratings represent average values obtained in accordance with accepted methods and are subject to normal manufacturing variations.
---- Dimensions and ratings are subject to change without notice. ----
Easy Installation
Order Information: Specify Quantity Pipe Size & Type Insulation Thickness Figure Number
6
11.63
12.63
12.63
13.63
14.88
15.88
18.13
20.13
22.13
23.13
25.13
27.13
29.13
33.13
Fig. BP8522
Design Data
Material:
BP8522 = Carbon Steel
BP8522CMS = Chrome Moly Steel
BP8522CSS = Carbon Silicon Steel
BP8522SS = Stainless Steel
Temperature Range
Range: +40F to +1200F
Higher temperatures available upon
request.
Jackets: Galvanized Steel ASTM A-527.
Glue: Industrial contact adhesive.
Structural inserts: High-density
calcium silicate asbestos free, treated
with water repellant.
Steel Straps: Carbon Steel ASTM A-36.
Fasteners: ASTM A-307 plated.
Coating: Primer coated or hot dipped
galvanized. Other coatings available
upon request.
Note:
For higher load ratings, see BP8523.
For loads in the downward direction
only see, BP8510-Series.
Load
lbs
810
970
1300
1940
2590
3230
4200
5170
5490
6460
7420
8070
8710
9040
0.63
0.63
0.63
0.63
0.63
0.875
0.875
0.875
1.125
1.125
1.125
1.125
1.125
1.125
0.50
0.50
0.50
0.50
0.50
0.50
0.50
0.50
0.50
0.50
0.50
0.50
0.50
0.50
0.50 x 3.00
0.50 x 3.00
0.50 x 3.00
0.50 x 4.00
0.50 x 4.00
0.50 x 5.00
0.50 x 5.00
0.50 x 6.00
0.50 x 6.00
0.50 x 6.00
0.50 x 7.00
0.50 x 7.00
0.50 x 7.00
0.50 x 7.00
1.50
1.50
1.50
2.00
2.00
3.00
3.00
4.00
4.00
4.00
5.00
5.00
5.00
5.00
0.625
0.625
0.625
0.625
0.625
0.625
0.625
0.75
0.75
0.75
0.875
0.875
0.875
0.875
6.19
6.44
6.72
7.25
7.75
8.25
9.31
10.69
11.81
12.31
13.44
14.44
15.44
17.69
5.63
6.13
6.69
7.75
8.75
9.75
11.88
13.88
16.13
17.13
19.13
21.13
23.13
27.13
7.25
7.75
7.75
8.25
8.75
9.31
10.31
11.81
12.81
13.31
14.44
15.44
16.44
18.69
7.75
8.75
8.75
9.75
10.75
11.88
13.88
16.13
18.13
19.13
21.13
23.13
25.13
29.13
8.25
8.75
8.75
9.31
9.81
10.31
11.44
12.81
13.81
14.31
15.44
16.44
17.44
19.69
9.75
10.75
10.75
11.88
12.88
13.88
16.13
18.13
20.13
21.13
23.13
25.13
27.13
31.13
9.31
9.81
9.81
10.31
10.94
11.44
12.44
13.81
14.81
15.31
16.44
17.44
18.44
20.69
11.88
12.88
12.88
13.88
15.13
16.13
18.13
20.13
22.13
23.13
25.13
27.13
29.13
33.13
BP8522
Pipe
Size
2
2 1/2
3
4
5
6
8
10
12
14
16
18
20
24
The load ratings represent average values obtained in accordance with accepted methods and are subject to normal manufacturing variations.
---- Dimensions and ratings are subject to change without notice. ----
Easy Installation
Order Information: Specify Quantity Pipe Size & Type Insulation Thickness Figure Number
Fig. BP8523
Design Data
Material:
BP8523 = Carbon Steel
BP8523CMS = Chrome Moly Steel
BP8523CSS = Carbon Silicon Steel
BP8523SS = Stainless Steel
Temperature Range
Range: +40F to +1200F
Higher temperatures available upon
request.
Jackets: Galvanized Steel ASTM A-527.
Glue: Industrial contact adhesive.
Structural inserts: High-density
calcium silicate asbestos free, treated
with water repellant.
Steel Straps: Carbon Steel ASTM A-36.
Fasteners: ASTM A-307 plated.
Coating: Primer coated or hot dipped
galvanized. Other coatings available
upon request.
Note:
For loads in the downward direction
only, see BP8510-Series.
BP8523
Pipe
Size
12
14
16
18
20
24
Load
lbs
7320
8610
9900
10760
11620
12050
1.125
1.125
1.125
1.125
1.125
1.125
0.50
0.50
0.63
0.63
0.63
0.63
0.50 x 7.00
0.50 x 7.00
0.63 x 7.00
0.63 x 7.00
0.63 x 7.00
0.63 x 7.00
5.00
5.00
5.00
5.00
5.00
5.00
0.875
0.875
1.00
1.00
1.00
1.25
11.94
12.44
13.69
14.69
15.69
18.19
16.13
17.13
19.38
21.38
23.38
27.38
12.94
13.44
14.69
15.69
16.69
19.19
18.13
19.13
21.38
23.38
25.38
29.38
13.94
14.44
15.69
16.69
17.69
20.19
20.13
21.13
23.38
25.38
27.38
31.38
14.94
15.44
16.69
17.69
18.69
21.19
The load ratings represent average values obtained in accordance with accepted methods and are subject to normal manufacturing variations.
---- Dimensions and ratings are subject to change without notice. ----
Easy Installation
Order Information: Specify Quantity Pipe Size & Type Insulation Thickness Figure Number
8
22.13
23.13
25.38
27.38
29.38
33.38
Section Contents
86-Series
Commercial & Industrial
Pipe Clamps and U-Bolts
Page(s)
Pictorial Selection Guide
1-5
Fig.
BP8610
BP8612
BP8620
BP8622
BP8630
Light
Light
Heavy
Heavy
Light
1
2
3
4
5
86-Series
Pipe Clamp
Neoprene Lined Pipe Clamp
Pipe Guide Clamp
Neoprene Lined Pipe Guide Clamp
U-Bolt
86-Series
86-Series
Purpose
Load
Class
Page
Fig.
For Installation On
BP8610
Bare Pipe
Insulated Pipe Support
Clamp
Clamp
Light
Light
1
1
BP8612
Bare Pipe
Bare Copper Tubing
Clamp
Clamp
Medium
Medium
2
2
BP8620
Bare Pipe
Insulated Pipe Support
Clamp
Guide
Heavy
Heavy
3
3
BP8622
Bare Pipe
Bare Copper Tubing
Clamp
Clamp
X-Heavy
X-Heavy
4
4
BP8630
Bare Pipe
Insulated Pipe Support
Guide
Guide
Light
Light
5
5
Order Information: Specify Quantity Pipe Size & Type Insulation Thickness Figure Number
A
Pipe Clamp
Fig. BP8610
Design Data
Steel: Galvanized 11 gauge x 1 1/4
wide ASTM A-527.
Fasteners: ASTM A-307 Plated.
Note:
For clamps designed for use on
copper tubing, see neoprene lined
clamps, models BP8612 and
BP8622.
For higher load ratings, see
BP8620.
For U-Bolts, see BP8630.
Can be sized to fit on all commercial
insulated shield models BP8110
through BP8190.
Pipe Size
Maximum
Lateral
Load - Lbs
3/4
1
1-1/4
1-1/2
2
2-1/2
3
3-1/2
4
5
6
8
10
12
50
50
50
50
50
50
50
50
50
50
50
50
50
50
BP8610
The load ratings represent average values obtained in accordance with accepted methods and are subject to normal manufacturing variations.
---- Dimensions and ratings are subject to change without notice. ----
Easy Installation
Order Information: Specify Quantity Pipe Size & Type Insulation Thickness Figure Number
Fig. BP8612
Design Data
Steel: Galvanized 11 gauge x 1 1/4
wide ASTM A-527.
Fasteners: ASTM A-307 Plated.
Note:
For non-lined clamps, see models
BP8610 and BP8620.
For higher load ratings, see
BP8620.
For U-Bolts, see BP8630.
Can be sized to fit on all commercial
insulated shield models BP8110
through BP8190.
BP8612
Pipe Size
Maximum
Lateral
Load - Lbs
3/4
1
1-1/4
1-1/2
2
2-1/2
3
3-1/2
4
5
6
8
10
12
50
50
50
50
50
50
50
50
50
50
50
50
50
50
The load ratings represent average values obtained in accordance with accepted methods and are subject to normal manufacturing variations.
---- Dimensions and ratings are subject to change without notice. ----
Easy Installation
Order Information: Specify Quantity Pipe Size & Type Insulation Thickness Figure Number
2
Fig. BP8620
Design Data
Steel: ASTM A36 1/4 x 1 1/2.
Fasteners: ASTM A-307 Plated.
Coating: Primer coated or hot dip
galvanized. Other coatings available
upon request.
Note:
For clamps designed for use on
copper tubing, see neoprene lined
clamps, models BP8612 and
BP8622.
For U-Bolts, see BP8630.
Can be sized to fit on all commercial
insulated shield models BP8110
through BP8190.
Pipe Size
Maximum
Lateral
Load - Lbs
3/4
1
1-1/4
1-1/2
2
2-1/2
3
3-1/2
4
5
6
8
10
12
200
200
200
200
400
400
400
400
400
400
400
400
400
400
BP8620
The load ratings represent average values obtained in accordance with accepted methods and are subject to normal manufacturing variations.
---- Dimensions and ratings are subject to change without notice. ----
Easy Installation
Order Information: Specify Quantity Pipe Size & Type Insulation Thickness Figure Number
Fig. BP8622
Design Data
Steel: ASTM A36 1/4 x 1 1/2.
Fasteners: ASTM A-307 Plated.
Coating: Primer coated or hot dip
galvanized. Other coatings available
upon request.
Note:
For non-lined clamps, see models
BP8610 and BP8620.
For U-Bolts, see BP8630.
Can be sized to fit on all commercial
insulated shield models BP8110
through BP8190.
BP8622
Pipe Size
Maximum
Lateral
Load - Lbs
3/4
1
1-1/4
1-1/2
2
2-1/2
3
3-1/2
4
5
6
8
10
12
200
200
200
200
400
400
400
400
400
400
400
400
400
400
The load ratings represent average values obtained in accordance with accepted methods and are subject to normal manufacturing variations.
---- Dimensions and ratings are subject to change without notice. ----
Easy Installation
Order Information: Specify Quantity Pipe Size & Type Insulation Thickness Figure Number
4
U-Bolt
Fig. BP8630
Design Data
Steel: Low carbon threaded rod.
Hex Nuts: ASTM A-563 Grade A.
Coating: Primer coated or hot dip
galvanized. Other coatings available
upon request.
Note:
For light duty pipe clamps, see
models BP8610-series.
For heavier duty pipe clamps, see
models BP8620-series.
Can be sized to fit on all commercial
insulated shield models BP8110
through BP8190.
Maximum
Lateral
Load-Lbs
Thread
1/2
3/4
1
1-1/4
1-1/2
2
2-1/2
3
3-1/2
4
50
50
50
50
50
50
50
50
50
50
1/4-20
1/4-20
1/4-20
3/8-16
3/8-16
3/8-16
1/2-13
1/2-13
1/2-13
1/2-13
BARE
A
B
1.25
1.5
1.75
2.25
2.5
2.88
3.5
4.13
4.63
5.13
1/2
2.75
3
3
3.5
3.63
3.88
4.38
4.63
4.88
5.13
2.5
2.5
2.88
3.38
3.5
4.13
4.88
5.38
5.88
6.38
3.38
3.38
3.63
4.13
4.13
4.38
4.88
5.13
5.38
5.75
Insulation Thickness
3/4
1
A
B
A
B
2.88
2.88
3.38
3.38
4.13
4.63
5.38
5.88
6.38
7.5
3.63
3.63
3.88
4.13
4.38
4.63
5.13
5.38
5.75
6.25
3.38
3.38
4
4.13
4.63
5.13
5.88
6.38
7.5
7.5
1-1/2
A
B
2
A
2-1/2
A
B
8.13
8.13
8.13
8.25
9.25
9.25
10.50
10.50
11.50
11.50
6.25
6.25
6.25
6.50
7.00
7.00
7.75
7.75
8.25
8.25
10.13
10.13
10.13
10.25
11.25
11.25
12.50
12.50
13.50
13.50
7.25
7.25
7.25
7.50
8.00
8.00
8.75
8.75
9.25
9.25
BP8630
Pipe
Size
The load ratings represent average values obtained in accordance with accepted methods and are subject to normal manufacturing variations.
---- Dimensions and ratings are subject to change without notice. ----
Easy Installation
Order Information: Specify Quantity Pipe Size & Type Insulation Thickness Figure Number
Section Contents
Misc.
Page(s)
1-3
Technical Information
4-7
Warranty
Misc.
SPSI Model #
BP Fig.
Rilco Part #
A1000
A2000
A3000
A4000
A5000
A6000
A7000
A7200
A7400
A8000
A8200
A8400
A9000
BP8110
BP8120
BP8130
BP8140
BP8150
BP8160
BP8170
BP8172
BP8174
BP8180
BP8182
BP8184
BP8490
HC-1000, HF-1000
HC-2000, HF-2000
B1000
B1100
B1200
B1300
B2000
B2100
B2200
B2300
B3000
B3100
B3200
B3300
B4000
B4100
B4200
B4300
B5000
B5100
B5200
B5300
B6000
B6100
BP8210
BP8211
BP8212
BP8213
BP8220
B08221
BP8222
BP8223
BP8230
BP8231
BP8232
BP8233
BP8240
BP8241
BP8242
BP8243
BP8250
BP8251
BP8252
BP8253
BP8260
BP8261
HF-5000, HR-5000
HF-6000, HR-6000
HF-7000
HF-7200
HF-7400
HF-8000
HF-8200
HF-8400
HC-9000
Misc.
HS-1000
HS-1100
HS-1200
HS-1300
HS-2000
HS-2100
HS-2200
HS-2300
HG-3000
HG-3100
HG-3200
HG-3300
HG-4000
HG-4100
HG-4200
HG-4300
HS-5000
HS-5100
HS-5200
HS-5300
HS-6000
HS-6100
1
Misc.
SPSI Model #
BP Fig.
Rilco Part #
B6200
B6300
B7000
B7100
B7200
B7300
B8000
B8100
B8200
B8300
BP8262
BP8263
BP8270
BP8271
BP8272
BP8273
BP8280
BP8281
BP8282
BP8283
HS-6200
HS-6300
HG-7000
HG-7100
HG-7200
HG-7300
HG-8000
HG-8100
HG-8200
HG-8300
C1000
C1100
C2000
C2100
C3000
C3100
C3200
C3300
C4000
C4100
C4200
C4300
BP8310
BP8311
BP8320
BP8321
BP8330
BP8331
BP8332
BP8333
BP8340
BP8341
BP8342
BP8343
HA-1000
HA-1100
HA-2000
HA-2100
N/A
N/A
N/A
N/A
HA-4000
HA-4100
HA-4200
HA-4300
D1000
D2000
D3000
D3100
D3200
D3300
D4000
D5000
D6000
D6100
D6200
D6300
BP8410
BP8420
BP8430
BP8431
BP8432
BP8433
BP8440
BP8450
BP8460
BP8461
BP8462
BP8463
HH-1000
HH-2000
HH-3000
HH-3100
HH-3200
HH-3300
HH-4000
HH-5000
HH-6000
HH-6100
HH-6200
HH-6300
BP Fig.
Rilco Part #
E1000
E1100
E1200
E1300
E2000
E2100
E2200
E2300
BP8510
BP8511
BP8512
BP8513
BP8520
BP8521
BP8522
BP8523
HV-1000
HV-1100
HV-1200
HV-1300
HV-2000
HV-2100
HV-2200
HV-2300
G1000
G1200
G2000
G2200
G3000
BP8610
BP8612
BP8620
BP8622
BP8630
N/A
N/A
N/A
N/A
N/A
Misc.
SPSI Model #
Technical Information
To
radian (rad)
degree
Multiply By
1.745329 x 10-2
5.729578 x 10+1
Area
foot2
inch 2
circular mil
square centimeter (cm2)
square meter (m2)
square meter (m2)
square meter (m2)
9.290304
6.451600
5,067075
1.550003
1.076391
1.550003
1.973525
Bending
Moment of
Torque
lbfft
lbfin
Nm
Nm
1.355818
1.129848 x 10-1
7.375621 x 10-1
8.850748
Force
pounds-force (lbf)
newtons (N)
4.448222
Length
foot (ft)
inch (in)
mil
inch (in)
meter (m)
meter (m)
meter (m)
micrometer (m)
meter (m)
meter (m)
meter (m)
micrometer (m)
foot (ft)
inch (in)
mil
Inch (in)
3.048000 x 10-1
2.540000 x 10-2
2.540000 x 10-5
2.540000 X 10+4
3.280840
3.937008 x 10+1
3.937008 x 10+4
3.937008 x 10-5
Mass
ounce (avoirdupois)
pound (avoirdupois)
on (short, 2000 lb)
on (long, 2240 lb)
kilogram (kg)
kilogram (kg)
kilogram (kg)
kilogram (kg)
kilogram (kg)
kilogram (kg)
kilogram (kg)
kilogram (kg)
ounce (avoirdupois)
pound (avoirdupois)
ton (short, 2000 lb)
ton (long, 2240 lb)
2.834952 x
4.535924 x
9.071847 x
1.016047 x
3.527396 x
2.204622
1.102311 x
9.842064 x
Mass Per
Unit Length
lb/ft
lb/in
kg/m
kg/m
1.488164
1.785797 x 10+1
6.719689 x 10-1
5.599741 x 10-2
Mass Per
Unit Volume
lb/ft 3
lb/in 3
kg/m 3
kg/m 3
lbs/ft 3
1.601846
2.767990
6.242797
3 612730
1.728000
Mass Per
Area Unit
lb/ft 2
kg/m 2
Pressure or
Stress
lbf/in2 (psi)
kip/in2 (ksi)
lbf/in2 (psi)
pascal (Pa)
pascal (Pa)
megapascals (MPa)
pascal (Pa)
pascal (Pa)
megapascals (MPa)
pound force per sq. inch (psi)
kip per sq. inch (ksi)
lbf/in2 (psi)
6.894757
6-894757
6.894757
1.450377
1.450377
1-450377
x
x
x
x
x
x
10+3
10+6
10-3
10-4
10-7
10+2
Section
Properties
S (m3)
S (in3)
1 (m4)
I (in4)
E (Pa)
E (psi)
1.638706
6.102374
4.162314
2.402510
6.894757
1.450377
x
x
x
x
x
x
10-5
10+4
10-7
10+6
10+3
10-4
Temperature
degree Fahrenheit
degree Celsius
degree Celsius
degree Fahrenheit
t C = (t F- 32) / 1.8
t F = 1.8 t C + 32
Volume
foot3
inch 3
cubic centimeter (cm3)
cubic meter (m3)
cubic meter (m3)
gallon (U.S. liquid)
2.831685
1.638706
6.102374
3.531466
6.102376
3.785412
Misc.
Angle
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
10-2
10-4
10-10
10-1
10+1
10+3
10+9
10-2
10-1
10+2
10+3
10+1
10-3
10-4
10-1
10+4
10-2
10-5
10+3
ASME ABBREVIATIONS
AISC
= American Institute of
Steel Construction
AISI
= American Iron & Steel
Institute
ANSI
= American National
Standards Institute
ASTM = American Society for
Testing & Materials
AWWA = American Water Works
Association
Dia.
= Diameter
Ft.
= Feet
Ga
= Gauge
I.D.
= Inside Diameter
In.
= Inch
Lbs.
= Pounds
Max.
= Maximum
Min.
= Minimum
MSS
= Manufacturers'
Standardization Society
NFPA = National Fire Protection
Association
O.D.
= Outside Diameter
Oz.
= Ounces
psi
= Pounds Per Square Inch
PVC
= Poly Vinyl Chloride
UNC
= Unified Course Threads
UNCR = Unified Course Threads
(Rounded Root)
METRIC SYMBOLS
cm
kg
kN
m
m
mm
MPa
N
Nm
Pa
10-2
10-2
10-2
10+1
10+4
10-3
=
=
=
=
=
=
=
=
=
=
centimeter
kilogram
kilonewton
meter
micrometer
millimeter
megapascal
newton
newton-meter
pascal
Technical Information
Pipe
Schedule
Std / 40
XS / 80
Std / 40
XS / 80
Std / 40
XS / 80
Std / 40
XS / 80
Std / 40
XS / 80
Std / 40
XS / 80
Std / 40
XS / 80
Std / 40
XS / 80
Std / 40
XS / 80
Std / 40
XS / 80
Std / 40
XS / 80
Std / 40
XS / 80
Std / 40
XS / 80
Std / 40
XS / 60
Std
XS
Std / 30
XS
Std / 30
XS / 40
Std
XS
Std / 20
XS / 30
Std / 20
XS
Std
XS / 20
Std
XS / 20
Std
XS / 20
PIPE DATA
Outside Dia.
in
mm
0.840
22
1.050
28
1.315
34
1.660
42
1.900
48
2.375
60
2.875
75
3.500
89
4.000
102
4.500
114
5.563
141
6.625
168
8.625
219
10.75
273
12.75
235
14.00
355.6
16.00
406.4
18.00
457.2
20.00
508.0
24.00
609.6
30.00
762.0
36.00
914.4
42.00
1066.8
Wall Thk
in
0.109
0.147
0.113
0.154
0.133
0.179
0.140
0.191
0.145
0.200
0.154
0.218
0.203
0.276
0.216
0.300
0.226
0.318
0.237
0.337
0.258
0.375
0.280
0.432
0.322
0.500
0.365
0.500
0.375
0.500
0.375
0.500
0.375
0.500
0.375
0.500
0.375
0.500
0.375
0.500
0.375
0.500
0.375
0.500
0.375
0.500
PIPE WEIGHT
w/ Gas, Air, Steam
w/ Water
lbs/ft
N/m
lbs/ft
0.9
12
1.0
1.1
16
1.2
1.1
17
1.4
1.5
22
1.7
1.7
25
2.1
2.2
32
2.5
2.3
33
2.9
3.0
44
3.6
2.7
40
3.6
3.6
53
4.4
3.7
53
5.1
5.0
73
6.3
5.8
85
7.9
7.7
112
9.5
7.6
111
11
10
150
13
9.1
133
13
13
182
16
11
157
16
15
219
20
15
213
23
21
303
29
19
277
31
29
417
40
29
417
50
43
633
63
40
591
75
55
799
87
50
723
99
65
955
112
55
796
114
72
1052
130
63
913
142
83
1208
159
71
1030
172
93
1364
192
79
1147
205
104
1520
227
95
1381
279
125
1831
306
119
1731
410
158
2299
444
143
2082
566
190
2766
607
167
2433
746
222
3234
794
N/m
14
17
20
24
30
36
43
52
53
64
75
92
115
139
157
191
195
239
238
291
340
418
460
582
733
922
1090
1271
1439
1641
1669
1892
2069
2326
2509
2800
2988
3313
4067
4460
5983
6478
8256
8853
10888
11587
Misc.
Technical Information
NOMINAL
TUBING SIZE
in.
mm
1/4
8
3/8
10
1/2
15
5/8
18
3/4
20
1
25
1-1/4
32
1-1/2
40
2
50
2-1/2
65
3
80
3-1/2
90
4
100
5
125
6
150
8
200
10
250
12
300
O.D. SIZE
in.
mm
0.375
9.5
0.500
12.7
0.625
15.9
0.750
19.1
0.875
22.2
1.125
28.6
1.375
34.9
1.625
41.3
2.125
54.0
2.625
66.7
3.125
79.4
3.625
92.1
4.125
104.8
5.125
130.2
6.125
155.6
8.125
206.4
10.125
257.2
12.125
308.0
WALL THICKNESS
in.
mm
0.030
0.8
0.035
0.9
0.040
1.0
0.042
1.1
0.045
1.1
0.050
1.3
0.055
1.4
0.060
1.5
0.070
1.8
0.080
2.0
0.090
2.3
0.100
2.5
0.110
2.8
0.125
3.2
0.140
3.6
0.200
5.1
0.250
6.4
0.280
7.1
WEIGHT OF TUBING
Lbs./Ft.
Kg/m
0.13
0.19
0.20
0.29
0.29
0.42
0.36
0.54
0.46
0.68
0.66
0.97
0.88
1.32
1.14
1.70
1.75
2.60
2.48
3.69
3.33
4.96
4.29
6.38
5.38
8.01
7.61
11.30
10.20
15.20
19.26
28.70
20.10
29.90
40.40
60.10
WEIGHT OF TUBING
FILLED WITH WATER
Lbs./Ft.
Kg/m
0.15
0.22
0.26
0.39
0.38
0.57
0.51
0.76
0.66
0.98
1.01
1.50
1.42
2.11
1.91
2.84
3.09
4.60
4.54
6.76
6.28
9.35
8.28
12.32
10.57
15.73
15.69
23.35
21.81
32.46
39.49
58.77
61.69
91.81
85.83
127.73
WALL THICKNESS
in.
mm
0.035
0.9
0.049
1.2
0.049
1.2
0.049
1.2
0.065
1.7
0.065
1.7
0.065
1.7
0.072
1.8
0.083
2.1
0.095
2.4
0.109
2.8
0.120
3.0
0.134
3.4
0.160
4.1
0.192
4.9
0.271
6.9
0.338
8.6
WEIGHT OF TUBING
Lbs./Ft.
Kg/m
0.14
0.21
0.27
0.40
0.34
0.51
0.42
0.63
0.64
0.95
0.84
1.25
1.04
1.55
1.36
2.02
2.06
3.07
2.92
4.35
4.00
5.95
5.12
7.62
6.51
9.69
9.67
14.4
13.87
20.6
25.90
38.5
40.30
60.0
Misc.
NOMINAL
TUBING SIZE
in.
mm
1/4
8
3/8
10
1/2
15
5/8
18
3/4
20
1
25
1-1/4
32
1-1/2
40
2
50
2-1/2
65
3
80
3-1/2
90
4
100
5
125
6
150
8
200
10
250
WEIGHT OF TUBING
FILLED WITH WATER
Lbs./Ft.
Kg/m
0.17
0.25
0.32
0.48
0.43
0.64
0.56
0.83
0.83
1.24
1.18
1.76
1.57
2.34
2.10
3.13
3.37
5.02
4.92
7.32
6.96
10.36
9.02
13.42
11.57
17.22
17.67
26.30
25.07
37.31
45.40
67.56
70.72
105.25
Technical Information
Useful Weight Formulas
PIPE
Weight (lb/ft) = 10.68 x T x (D - T) x F
PIPE CONTENTS
Weight (lb/ft) = 0.3405 x G x (D - 2T)2
ROUND ROD
Weight (lb/ft) = 2.67D2
LEGEND
D = Outside Diameter (inches)
F = Material Weight Factor
G = Specific Gravity of Pipe Contents
Normally 1.0 for water, 0 for air and steam.
L = Length (inches)
T = Pipe Wall, Plate, or Bar Thickness (inches)
W = Width (inches)
1"
.057
.051
.066
.080
.091
.10
.15
.13
.15
.17
1-1/2"
.10
.12
.11
.14
.19
.17
.23
.21
.24
.27
.34
.43
.50
.51
.57
.64
.70
.83
2"
.16
.15
.21
.21
.27
.25
.31
.30
.34
.38
.47
.59
.68
.70
.78
.87
.96
1.13
4-1/2"
.83
.81
...
.96
1.04
1.13
1.36
1.54
1.74
1.81
2.01
2.21
2.40
2.80
5"
.97
1.10
1.20
1.34
1.56
1.76
1.99
2.07
2.29
2.51
2.73
3.16
5-1/2"
1.75
1.99
2.24
2.34
2.58
2.82
3.06
3.54
6"
2.50
2.62
2.88
3.14
3.4
3.92
General Formula: For pipe sizes not shown in the table above (special
O.D. pipe, etc.), use the following formula to determine the insulation
weight:
Insulation Weight: (lb/ft) = 0.0218 x I x T x (T + D)
Misc.
WARRANTY
Bergen Pre-Insulated Pipe Supports, Inc. (BPIPS) warrants to the original buyer (the
Buyer) of products manufactured by it that all such products will be free from defects in
material and workmanship for a period of one (1) year after the date of shipment when used in
the manner and for the purpose recommended by BPIPS. BPIPS does not warrant goods
manufactured by other parties, except to the extent that such goods are covered by a warranty to
BPIPS. Notice of a claim for a breach of a warranty must be given to BPIPS within thirty (30)
days after the date that the Buyer first has knowledge of an alleged breach of warranty, but in
no event later than one (1) year after the date of shipment. BPIPSs obligations under this
Warranty are limited to its repair or replacement of those products that it determines, to its
satisfaction, are defective, and it shall not be liable for any charge or expense incurred by the
Buyer in repairing or replacing said products. Notwithstanding anything else contained herein to
the contrary, BPIPSs liability under this Warranty for defective products is limited to the net
sales price of such products. The foregoing constitutes the Buyers sole and exclusive remedy for
defective products.
In the event that BPIPS provides engineering design or fabrication services, the Buyers
acceptance of BPIPSs design or delivery of the products shall relieve BPIPS of all further
obligations with respect to such design and fabrication, except to the extent that BPIPS may
otherwise expressly provide in a product warranty. In no event, shall BPIPS be responsible for
design errors due to inaccurate or incomplete information provided by the Buyer or its
representatives. BPIPS reserves the right to revise product design without notification.
THIS WARRANTY IS IN LIEU OF ALL OTHER WARRANTIES, EXPRESSED OR
IMPLIED, INCLUDING WARRANTIES OF MERCHANTABILITY, FITNESS FOR A
PARTICULAR PURPOSE OR ANY OTHER MATTER. IN NO EVENT AND UNDER
NO CIRCUMSTANCE SHALL BPIPS BE LIABLE FOR (A) PERSONAL INJURY OR
PROPERTY DAMAGES OR (B) CONSEQUENTIAL, SPECIAL OR INCIDENTAL
DAMAGES, WHETHER FOR BREACH OF CONTRACT OR WARRANTY,
NEGLIGENCE OR ANY OTHER TORTUOUS ACT OR OMISSION. THIS WARRANTY
SHALL NOT APPLY TO PRODUCTS THAT HAVE BEEN SUBJECT TO ALTERATION
OR REPAIR MADE BY A PARTY OTHER THAN BPIPS, ACCIDENT, ABUSE, OR
MISUSE. THIS WARRANTY SUPERCEDES ALL CONTRARY OBLIGATIONS
IMPOSED ON BPIPS BY ANY PURCHASE ORDER.
Misc.
The terms of this Warranty may not be modified or changed except by a writing signed
by an authorized officer of BPIPS.
SALES OFFICES
MASSACHUSETTS
225 Merrimac Street
Woburn, MA 01801
Tel: 781.935.9550
Fax: 781.938.0026
e-mail: bpwoburn@bergenpower.com
PENNSYLVANIA
829 Beaver Avenue
Pittsubrgh, PA 15233
Tel: 412.323.1545
Fax: 412.323.1904
e-mail: bppitt@bergenpower.com
MANUFACTURING PLANT
484 Giliffa Street
Donora Industrial Park
Donora, PA 15033