You are on page 1of 2

Project No.

Date 28/4/02 Computed by -A. HASHEM Approved by _

DESIGN CALCULATION SHEET

General Sheet No. of

Subject Building

Checking Test1

Checked by _

Calculation of Deflection According to ACI 318M-99


Concrete Compressive Strength (f'c) Concrete Modulus of Rupture (fr) Concrete Modulus of Elasticity (Ec) n (Es/Ec) Section Properties Thickness of Section (t) Breadth of Section (b) Tension Reinforcement (As) Span (l) Nutral Axis Depth (z) Gross Moment of Inertia (Ig) Cracked Moment of Inertial (Icr) Cracking Moment (Mcr) = = = = = = = = = = = = 300.00 Kg/cm2 3.83 MPa 2.6E+04 MPa 7.77 = 30.00 MPa (Eq. 9-9) (Clause 8.5.1) (Clause 8.5.2) 55.00 cm 5.00 cm 2.62 cm2

60.00 cm 30.00 cm 8.00 cm2 5.00 m 12.86 cm 540000.00 cm4 132733.36 cm4 6.90E+07 N mm = = = = =

Depth of Ten. Reinforcement (d) = Depth of Comp. Reinforcement (d') = Compression Reinforcement (As') =

= = =

5.40E+09 mm4 1.33E+09 mm4 6.90 m. t = = 5.0E+07 N. mm 3.5E+07 N. mm

(Eq. 9-8)

Service Straining Actions Bending Moment Due to Dead Load only (Md) Bending Moment Due to Live Load only (Ml) % of Sustained Load from the Live Load % of Gross Inertia Used in Calculation Bending Moment Due to Sustained Load (Msus)

5.00 m.t 3.50 m.t 50% 100% 6.75 m.t

6.8E+07 N. mm

Calculated Short Time Deflection (Calculated by total or percentage of gross moment of inertia) Deflection due to Dead Load (Di)d = 0.6000 cm = 6.000 mm Deflection due to Live Load (Di)l = 0.4000 cm = 4.000 mm Efffective Moment of Inertia (Eq. 9-7) Under Dead Load Only (Ie)d = 540000.00 cm4 = 5.40E+09 mm4 Under Sustained Load (Ie)sus = 540000.00 cm4 = 5.40E+09 mm4 Under Dead + Live Load (Ie)d+l = 350712.822 cm4 = 3.51E+09 mm4 Modified Short time Deflection Deflection due to Dead Load (Di)d = 0.6000 cm Deflection due to Sustained Load (Di)sus = 0.8000 cm Deflection due to Dead + Live Load (Di)d+l = 1.5397 cm Deflection due to Live Load (Di)l = 0.9397 cm Additional Long Term Deflection (Clause 9.5.2.5) For 5 years or more (Dlong) For 12 months (Dlong) = 1.03762 cm = 1.48231 cm For 6 months (Dlong) For 3 months (Dlong) = 0.88939 cm = 0.74116 cm

Results
-- Flat roofs not supporting and not attached to nonstructural elements likely to be damaged by large defelections: (Di)l = 0.9397 cm < l/180 = 2.7778 cm -- Floors not supporting and not attached to nonstructural elements likely to be damaged by large deflections: (Di)l = 0.9397 cm < l/360 = 1.3889 cm -- Roof or floor construction supporting or attached to nonstructural elements likely to be damaged by large deflections: (Dlong) + (Di)l = 2.4220 cm > l/480 = 1.04167 cm -- Roof or floor construction supporting or attached to nonstructural elements not likely to be damaged by large deflections: (Dlong) + (Di)l = 2.4220 cm > l/240 = 2.0833 cm

187190816.xls.ms_office - Rev. 0

Rectangular Section

Project No.

Date 28/4/02 Computed by -A. HASHEM Approved by _

DESIGN CALCULATION SHEET

General Sheet No. of

Subject Building

Checking Test2

Checked by _

Calculation of Deflection According to ACI 318M-99


Concrete Compressive Strength (f'c) Concrete Modulus of Rupture (fr) Concrete Modulus of Elasticity (Ec) n (Es/Ec) Section Properties Thickness of Section (t) Breadth of Wib (bw) Breadth of Flange (bf) Tension Reinforcement (As) Span (l) Nutral Axis Depth (z) Gross Moment of Inertia (Ig) Cracked Moment of Inertial (Icr) Cracking Moment (Mcr) = = = = = = = = = = = = = 250.00 Kg/cm2 3.50 MPa 2.4E+04 MPa 8.51 cm cm cm = 25.00 MPa (Eq. 9-9) (Clause 8.5.1) (Clause 8.5.2) = = = = 65.00 5.00 15.00 2.62 cm cm cm cm2

cm2 5.00 m 9.29 cm 1504252.72 cm4 = 243737.77 cm4 = 1.15E+08 N mm = = = = = =

70.00 30.00 120.00 8.00

Depth of Ten. Reinforcement (d) Depth of Comp. Reinforcement (d') Flange Thickness (tf) Compression Reinforcement (As')

1.50E+10 mm4 2.44E+09 mm4 11.51 m. t m.t m.t = = 1.0E+08 N. mm 8.0E+07 N. mm

(Eq. 9-8)

Service Straining Actions Bending Moment Due to Dead Load only (Md) Bending Moment Due to Live Load only (Ml) % of Sustained Load from the Live Load % of Gross Inertia Used in Calculation Bending Moment Due to Sustained Load (Msus)

10.00 8.00

30% 100% 12.4 m.t

1.2E+08 N. mm

Calculated Short Time Deflection (Calculated by total or percentage of gross moment of inertia) Deflection due to Dead Load (Di)d = 1.0000 cm = 10.000 mm Deflection due to Live Load (Di)l = 0.5000 cm = 5.000 mm Efffective Moment of Inertia Under Dead Load Only (Ie)d Under Sustained Load (Ie)sus Under Dead + Live Load (Ie)d+l (Eq. 9-7) = = = 1504252.72 cm4 1250592.20 cm4 572903.203 cm4 = = = = 1.0000 1.3833 3.9385 2.9385 = = = cm cm cm cm For 12 months (Dlong) For 3 months (Dlong) = = (Clause 9.5.2.5) 1.81465 cm 1.29618 cm 1.50E+10 mm4 1.25E+10 mm4 5.73E+09 mm4

Modified Short time Deflection Deflection due to Dead Load (Di)d Deflection due to Sustained Load (Di)sus Deflection due to Dead + Live Load (Di)d+l Deflection due to Live Load (Di)l

Additional Long Term Deflection For 5 years or more (Dlong) = 2.59236 cm For 6 months (Dlong) = 1.55542 cm

Results
-- Flat roofs not supporting and not attached to nonstructural elements likely to be damaged by large defelections: (Di)l = 2.9385 cm > l/180 = 2.7778 cm -- Floors not supporting and not attached to nonstructural elements likely to be damaged by large deflections: (Di)l = 2.9385 cm > l/360 = 1.3889 cm -- Roof or floor construction supporting or attached to nonstructural elements likely to be damaged by large deflections: (Dlong) + (Di)l = 5.5309 cm > l/480 = 1.04167 cm -- Roof or floor construction supporting or attached to nonstructural elements not likely to be damaged by large deflections: (Dlong) + (Di)l = 5.5309 cm > l/240 = 2.0833 cm
187190816.xls.ms_office - Rev. 0 T - Section