configuration guide

hp StorageWorks enterprise virtual array


hardware
Product Version: 3.0 Second Edition (May 2003) Part Number: AA-RS28B-TE This guide describes the various hardware configurations used for the HP StorageWorks Enterprise Virtual Array. It discusses the quantity of various hardware components in each configuration and how the hardware components are connected to each other. The expansion of existing racks is also discussed. For the latest version of this document and other storage system documentation, visit the HP storage website at: http://welcome.hp.com/country/us/eng/prodserv/storage.html.

Copyright 2001 - 2003 Hewlett-Packard Development Company, L.P. Hewlett-Packard Company makes no warranty of any kind with regard to this material, including, but not limited to, the implied warranties of merchantability and fitness for a particular purpose. Hewlett-Packard shall not be liable for errors contained herein or for incidental or consequential damages in connection with the furnishing, performance, or use of this material. This document contains proprietary information, which is protected by copyright. No part of this document may be photocopied, reproduced, or translated into another language without the prior written consent of Hewlett-Packard. The information contained in this document is subject to change without notice. Compaq Computer Corporation is a wholly-owned subsidiary of Hewlett-Packard Company. All other product names mentioned herein may be trademarks of their respective companies. Hewlett-Packard Company shall not be liable for technical or editorial errors or omissions contained herein. The information is provided as is without warranty of any kind and is subject to change without notice. The warranties for Hewlett-Packard Company products are set forth in the express limited warranty statements accompanying such products. Nothing herein should be construed as constituting an additional warranty. Printed in the U.S.A.

Enterprise Virtual Array Hardware Configuration Guide Second Edition (May 2003) Part Number: AA-RS28B-TE

contents

About this Guide. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 Overview. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10 Intended Audience . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10 Related Documentation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10 Conventions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11 Document Conventions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11 Text Symbols . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11 Equipment Symbols . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12 Rack Stability . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13 Getting Help . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .14 HP Technical Support . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .14 HP Storage Website . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .14 HP Authorized Reseller . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .14 1 Enterprise Virtual Array Hardware . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 Storage Racks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .16 41U Rack . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .16 42U Rack . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .16 2C6D Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .17 2C12D Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .18 8C8D Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .19 2C2D Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .20 0C6D Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .21 0C12D Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .22 Fibre Channel Drive Enclosures. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .24 HSV110 Controllers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .25 Fibre Channel Loop Switches. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .26 Fibre Channel Cables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .27 Enterprise Virtual Array Configurations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29 2C12D Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .30 Enclosure Address Bus Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .30 Fibre Channel Loop Configurations. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .31 Cable Management Configurations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .39 Cable Management Arms . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .39 Cable Containment Spools . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .40 2C6D Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .41
3

Contents

Enterprise Virtual Array Hardware Configuration Guide

Contents

Enclosure Address Bus Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .41 Fibre Channel Loop Configurations. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .42 Cable Management Configurations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .50 8C8D Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .51 Enclosure Address Bus Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .51 Fibre Channel Loop Configurations. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .52 Cable Management Configurations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .56 2C2D Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .57 Enclosure Address Bus Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .57 Fibre Channel Loop Configurations. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .58 Cable Management Configurations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .62 2C12D + 0C6D Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .63 Enclosure Address Bus Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .63 Fibre Channel Loop Configurations. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .64 2 x 2C12D + 0C12D Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .73 Enclosure Address Bus Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .73 Fibre Channel Loop Configurations. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .74 3 Upgrading Existing Racks to Enterprise v2.0 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 83 Expansion Panels . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .85 FC Loop Switches. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .85 Fibre Channel Cable Reconfiguration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .85 Expanding a Rack. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 87 Adding FC Drive Enclosures to a Rack . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .88 2C6D Configuration. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .88 2C6D + 6D Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .89 Enclosure Address Bus Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .89 Fibre Channel Loop Configurations. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .90 0C6D + 6D Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .99 Enclosure Address Bus Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .99 Fibre Channel Loop Configurations. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .99

A Regulatory Notices and Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 109 Regulatory Notices . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .110 Federal Communications Commission Notice. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .110 FCC Class A Certification. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .110 Class A Equipment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .110 Class B Equipment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .111 Declaration of Conformity for Products Marked with the FCC Logo, United States Only . . . . . . . .111 Modifications. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .111 Cables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .111 Laser Device. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .111 Laser Safety Warnings. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .112 Compliance with CDRH Regulations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .112 Certification and Classification Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .112 Canadian Notice (Avis Canadien) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .112 Class A Equipment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .112 Class B Equipment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .113 European Union Notice . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .113
4 Enterprise Virtual Array Hardware Configuration Guide

Contents

Notice for France . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .113 Germany Noise Declaration. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .113 Japanese Notice . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .114 Harmonics Conformance (Japan) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .114 Taiwanese Notice . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .114 Country-Specific Certifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .115 Fibre Channel Drive Enclosure Specifications. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .116 Physical Specifications. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .116 Environmental Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .117 Power Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .118 Fibre Channel Switch Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .120 Controller Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .121 Physical Specifications. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .121 Power Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .121 Environmental Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .122 Enterprise Rack. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .123 Physical Specifications. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .123 Environmental Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .124 Power Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .125 Glossary. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 127 Figures 1 41U rackfront and rear views. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 42U rackfront and rear views. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 2C6D configurationrear view. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 2C12D configurationrear view. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 8C8D configurationrear view. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 2C2D configurationfront and rear views . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 0C6D configurationrear view. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 0C12D configurationrear view. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 FC drive enclosurefront and rear views . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 HSV110 controllerfront and rear views . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 FC loop switchfront and rear views . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 2C12D configurationenclosure address bus cables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 2C12D configurationFibre Channel loop 1A with FC loop switch . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 2C12D configurationFibre Channel loop 1B with FC loop switch . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 2C12D configurationFibre Channel loop 2A with FC loop switch . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 2C12D configurationFibre Channel loop 2B with FC loop switch . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17 2C12D configurationFibre Channel loop 1A with expansion panel . . . . . . . . . . . . . . . . . . . . . . . . . . . 18 2C12D configurationFibre Channel loop 1B with expansion panel . . . . . . . . . . . . . . . . . . . . . . . . . . . 19 2C12D configurationFibre Channel loop 2A with expansion panel . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 2C12D configurationFibre Channel loop 2B with expansion panel . . . . . . . . . . . . . . . . . . . . . . . . . . . 21 2C12D cable management configuration. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22 2C6D configurationenclosure address bus cables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23 2C6D configurationFibre Channel loop 1A with FC loop switch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24 2C6D configurationFibre Channel loop 1B with FC loop switch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25 2C6D configurationFibre Channel loop 2A with FC loop switch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26 2C6D configurationFibre Channel loop 2B with FC loop switch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27 2C6D configurationFibre Channel loop 1A with expansion panel . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Enterprise Virtual Array Hardware Configuration Guide

16 17 18 19 20 21 22 23 24 25 26 30 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46
5

Contents

28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77
6

2C6D configurationFibre Channel loop 1B with expansion panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47 2C6D configurationFibre Channel loop 2A with expansion panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48 2C6D configurationFibre Channel loop 2B with expansion panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49 2C6D cable management configuration. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50 8C8D configurationenclosure address bus cables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51 8C8D configurationFibre Channel loop 1A. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52 8C8D configurationFibre Channel loop 1B . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53 8C8D configurationFibre Channel loop 2A. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54 8C8D configurationFibre Channel loop 2B . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55 8C8D cable management configuration. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 56 2C2D configurationenclosure address bus cables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57 2C2D configurationFibre Channel loop 1A. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 58 2C2D configurationFibre Channel loop 1B . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 59 2C2D configurationFibre Channel loop 2A. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60 2C2D configurationFibre Channel loop 2B . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 61 2C2D cable management configuration. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 62 2C12D + 0C6D configurationenclosure address bus cables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 64 2C12D + 0C6D configurationFibre Channel loop 1A with FC loop switch . . . . . . . . . . . . . . . . . . . . . 65 2C12D + 0C6D configurationFibre Channel loop 1B with FC loop switch . . . . . . . . . . . . . . . . . . . . . 66 2C12D + 0C6D configurationFibre Channel loop 2A with FC loop switch . . . . . . . . . . . . . . . . . . . . . 67 2C12D + 0C6D configurationFibre Channel loop 2B with FC loop switch . . . . . . . . . . . . . . . . . . . . . 68 2C12D + 0C6D configurationFibre Channel loop 1A with expansion panels . . . . . . . . . . . . . . . . . . . 69 2C12D + 0C6D configurationFibre Channel Loop 1B with expansion panels . . . . . . . . . . . . . . . . . . . 70 2C12D + 0C6D configurationFibre Channel loop 2A with expansion panels . . . . . . . . . . . . . . . . . . . 71 2C12D + 0C6D configurationFibre Channel loop 2B with expansion panels. . . . . . . . . . . . . . . . . . . . 72 2 x 2C12D + 0C12D configurationenclosure address bus cables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 74 2 x 2C12D + 0C12D configurationFibre Channel loop 1A with FC loop switch . . . . . . . . . . . . . . . . . 75 2 x 2C12D + 0C12D configurationFibre Channel loop 1B with FC loop switch . . . . . . . . . . . . . . . . . 76 2 x 2C12D + 0C12D configurationFibre Channel loop 2A with FC loop switch . . . . . . . . . . . . . . . . . 77 2 x 2C12D + 0C12D configurationFibre Channel loop 2B with FC loop switch . . . . . . . . . . . . . . . . . 78 2 x 2C12D + 0C12D configurationFibre Channel loop 1A with expansion panels . . . . . . . . . . . . . . . 79 2 x 2C12D + 0C12D configurationFibre Channel loop 1B with expansion panels. . . . . . . . . . . . . . . . 80 2 x 2C12D + 0C12D configurationFibre Channel loop 2A with expansion panels . . . . . . . . . . . . . . . 81 2 x 2C12D + 0C12D configurationFibre Channel loop 2B with expansion panels. . . . . . . . . . . . . . . . 82 Expansion panels versus FC loop switches . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 84 Fibre Channel cabling comparison Enterprise v1.0 to Enterprise v2.0 . . . . . . . . . . . . . . . . . . . . . . . . . 86 2C6D configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 88 2C6D + 6D configurationenclosure address cables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 89 2C6D + 6D configurationFibre Channel loop 1A with FC loop switch . . . . . . . . . . . . . . . . . . . . . . . . 91 2C6D + 6D configurationFibre Channel loop 1B with FC loop switch . . . . . . . . . . . . . . . . . . . . . . . . 92 2C6D + 6D configurationFibre Channel loop 2A with FC loop switch . . . . . . . . . . . . . . . . . . . . . . . . 93 2C6D + 6D configurationFibre Channel loop 2B with FC loop switch . . . . . . . . . . . . . . . . . . . . . . . . 94 2C6D + 6D configurationFibre Channel loop 1A with expansion panel. . . . . . . . . . . . . . . . . . . . . . . . 95 2C6D + 6D configurationFibre Channel loop 1B with expansion panel . . . . . . . . . . . . . . . . . . . . . . . . 96 2C6D + 6D configurationFibre Channel loop 2A with expansion panel. . . . . . . . . . . . . . . . . . . . . . . . 97 2C6D + 6D configurationFibre Channel loop 2B with expansion panel . . . . . . . . . . . . . . . . . . . . . . . . 98 0C6D + 6D configurationenclosure address bus cables. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 99 0C6D + 6D configurationFibre Channel loop 1A . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 100 0C6D + 6D configurationFibre Channel loop 1B . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 101 0C6D + 6D configurationFibre Channel loop 2A . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 102
Enterprise Virtual Array Hardware Configuration Guide

Contents

78 79 80 81 82 83

0C6D + 6D configurationFibre Channel loop 2B . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0C6D + 6D configurationFibre Channel loop 1A with expansion panels . . . . . . . . . . . . . . . . . . . . . . 0C6D + 6D configurationFibre Channel loop 1B with expansion panels . . . . . . . . . . . . . . . . . . . . . . 0C6D + 6D configurationFibre Channel loop 2A with expansion panels . . . . . . . . . . . . . . . . . . . . . . 0C6D + 6D configurationFibre Channel loop 2B with expansion panels . . . . . . . . . . . . . . . . . . . . . . Typical enclosure certification label . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

103 104 105 106 107 115

Tables 1 Document Conventions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 2 LC-SC cables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27 3 LC-LC Cables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27 4 Fibre Channel Loop Locations in Rack . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31 5 Fibre Channel Loop Locations in Rack . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 90 6 Drive Enclosure Physical Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 116 7 Drive Enclosure Elements Physical Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 116 8 Environmental Operating Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 117 9 Environmental Shipping or Short-Term Storage Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 118 10 Enterprise Storage System AC Input Line Voltages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 118 11 AC Input Current and Wattage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 119 12 Output Voltage and Current Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 119 13 Dual Power Supply Configuration Power Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 119 14 Fibre Channel Switch Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 120 15 Controller Physical Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 121 16 Controller Power Supply AC Power Requirements. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 121 17 AC Input Current and Wattage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 122 18 Controller Power Supply Output Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 122 19 Enterprise 42U Storage System Rack Physical Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 123 20 Enterprise 42U Storage System Rack Shipping Dimensions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 123 21 Enterprise 41U Storage System Rack Physical Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 123 22 Enterprise 41U Storage System Rack Shipping Dimensions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 124 23 Environmental Operating Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 124 24 Environmental Shipping or Short Term Storage Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 124 25 Enterprise Storage System AC Power Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 125

Enterprise Virtual Array Hardware Configuration Guide

Contents

Enterprise Virtual Array Hardware Configuration Guide

about this guide

This hardware configuration guide provides information to help you:


Learn about the EnterpriseAbout Virtual Array hardware components. this Guide Understand the supported storage rack configurations. Convert an Enterprise Virtual Array v1.0 storage rack configuration into an Enterprise Virtual Array v2.0 storage rack configuration. Expand an Enterprise Virtual Array with drive enclosures. Understand the supported Fibre Channel cable configurations. Overview, page 10 Conventions, page 11 Rack Stability, page 13 Getting Help, page 14

About this Guide

About this Guide topics include:


Enterprise Virtual Array Hardware Configuration Guide

About this Guide

Overview
This section covers the following topics:

Intended Audience Related Documentation

Intended Audience
This book is intended for use by Enterprise Virtual Array administrators who are experienced with the following:

Working with Fibre Channel cables. Working with Fibre Channel loop switches. Maintaining and operating Storage Area Networks (SANs).

Related Documentation
Additional documentation is available from the HP website at: http://welcome.hp.com/country/us/eng/prodserv/storage.html.

10

Enterprise Virtual Array Hardware Configuration Guide

About this Guide

Conventions
Conventions consist of the following:

Document Conventions Text Symbols Equipment Symbols

Document Conventions
The document conventions included in Table 1 apply in most cases.
Table 1: Document Conventions Element Cross-reference links Key and field names, menu items, buttons, and dialog box titles File names, application names, and text emphasis User input, command and directory names, and system responses (output and messages) Variables Website addresses Bold Convention Blue text: Figure 1

Italics
Monospace font COMMAND NAMES are uppercase monospace font unless they are case sensitive <monospace, italic font> Blue, underlined sans serif font text: http://www.hp.com

Text Symbols
The following symbols may be found in the text of this guide. They have the following meanings.
WARNING: Text set off in this manner indicates that failure to follow directions in the warning could result in bodily harm or loss of life.

Caution: Text set off in this manner indicates that failure to follow directions could result in damage to equipment or data.

Note: Text set off in this manner presents commentary, sidelights, or interesting points of information.

Enterprise Virtual Array Hardware Configuration Guide

11

About this Guide

Equipment Symbols
The following equipment symbols may be found on hardware to which this guide pertains. They have the following meanings.
These symbols, which mark an enclosed surface or area of the equipment, indicate the presence of electrical shock hazards. The enclosed area contains no operator serviceable parts. WARNING: To reduce the risk of injury from electrical shock hazards, do not open this enclosure.

These symbols, which mark an RJ-45 receptacle, indicate a network interface connection. WARNING: To reduce the risk of electrical shock, fire, or damage to the equipment, do not plug telephone or telecommunications connectors into this receptacle.

These symbols, which mark a surface or area of the equipment, indicate the presence of a hot surface or hot component. Contact with this surface could result in injury. WARNING: To reduce the risk of injury from a hot component, allow the surface to cool before touching.

These symbols, which mark power supplies or systems, indicate the presence of multiple sources of power. WARNING: To reduce the risk of injury from electrical shock, remove all power cords to completely disconnect power from the power supplies and systems.

These symbols, which mark a product or assembly, indicate that the component exceeds the recommended weight for one individual to handle safely. WARNING: To reduce the risk of personal injury or damage to the equipment, observe local occupational health and safety requirements and guidelines for manually handling material.

12

Enterprise Virtual Array Hardware Configuration Guide

About this Guide

Rack Stability
Rack stability protects personnel and equipment.
WARNING: To reduce the risk of personal injury or damage to the equipment, be sure that: The leveling jacks are extended to the floor. The full weight of the rack rests on the leveling jacks. In single rack installations, the stabilizing feet are attached to the rack. In multiple rack installations, the racks are coupled. Only one rack component is extended at any time. A rack may become unstable if more than one rack component is extended for any reason.

Enterprise Virtual Array Hardware Configuration Guide

13

About this Guide

Getting Help
If you still have a question after reading this guide, contact an HP Authorized Service Representative or access our website: http://www.hp.com.

HP Technical Support
In North America, call technical support at 1-800-354-9000, available 24 hours a day, 7 days a week.
Note: For continuous quality improvement, calls may be recorded or monitored.

Outside North America, call technical support at the nearest location. Telephone numbers for worldwide technical support are listed on the HP website under support: http://thenew.hp.com/country/us/eng/support.html. Be sure to have the following information available before calling:

Technical support registration number (if applicable) Product serial numbers Product model names and numbers Applicable error messages Operating system type and revision level Detailed, specific questions

HP Storage Website
The HP website has the latest information on this product, as well as the latest drivers. Access storage at: http://welcome.hp.com/country/us/eng/prodserv/storage.html. From this website, select the appropriate product or solution.

HP Authorized Reseller
For the name of your nearest HP authorized reseller:

In the United States, call 1-800-345-1518 In Canada, call 1-800-263-5868 Elsewhere, see the HP website for locations and telephone numbers: http://www.hp.com.

14

Enterprise Virtual Array Hardware Configuration Guide

Enterprise Virtual Array Hardware

This chapter briefly discusses the hardware components in the Enterprise Virtual Array. The following topics are discussed:

Storage Racks, page 16 Fibre Channel Drive Enclosures, page 24 HSV110 Controllers, page 25 Fibre Channel Loop Switches, page 26 Fibre Channel Cables, page 27

Enterprise Virtual Array Hardware Configuration Guide

15

Enterprise Virtual Array Hardware

Storage Racks
The Enterprise Virtual Array can be housed in two different storage racks: the 42U rack or the 41U rack. Both storage racks can hold a maximum of 12 Fibre Channel drive enclosures (FC drive enclosures) and two controllers.

41U Rack
The 41U rack is graphite in color and 993 mm (39.1 inches) deep. The storage rack features standard 19-inch mounting rails. The 41U rack can support Enterprise Virtual Array configurations that include Fibre Channel loop switches (FC loop switches). Figure 1 shows the front and rear views of a 41U rack.
Front 1 Rear 1
1 2 3 FC drive enclosure FC loop switches Controller pair

2 41U 3 2

2 3 2

CXO7872B

Figure 1: 41U rackfront and rear views

42U Rack
The 42U rack is opal in color and 909 mm (35.8 inches) deep. The storage rack features standard 19-inch mounting rails. The 42U rack can support Enterprise Virtual Array configurations that include FC loop switches or expansion panels. Figure 2 shows the front and rear views of a 42U rack.

16

Enterprise Virtual Array Hardware Configuration Guide

Enterprise Virtual Array Hardware

Front 1

Rear 1

1 2 3

FC drive enclosure FC loop switches Controller pair

2 42U 3 2

2 3 2

CXO7873B

Figure 2: 42U rackfront and rear views

2C6D Features
The following features are included in the 2C6D configuration:

One storage rack Two controllers Six 14-drive bay FC drive enclosures Four FC loop switches Sixteen internal Fibre Channel cables Seven 2-port enclosure address bus junction boxes Eight AC strips Two 0U PDUs

Note: Disks must be ordered separately.

The 2C6D configuration can contain a maximum of 3.1 TB (84 36.4-GB disks), 6.1 TB (84 72.8-GB disks), or 12.3 TB (84 146-GB disks) of storage capacity.

Enterprise Virtual Array Hardware Configuration Guide

17

Enterprise Virtual Array Hardware

Note: The 2C6D configuration can be expanded to increase storage capacity. However, there is a limit to expansion; each controller pair can support a maximum of 240 disks.

Figure 3 shows the rear view of the 2C6D configuration.


1 2 3 4 3U blank FC drive enclosure FC loop switch Controller pair

3 4 3

CXO7874B

Figure 3: 2C6D configurationrear view

2C12D Features
The following features are included in the 2C12D:

One storage rack Two controllers Twelve 14-drive bay FC drive enclosures Four FC loop switches Thirty-two internal Fibre Channel cables Seven 2-port enclosure address bus junction boxes Eight AC strips Two 0U PDUs

Note: Disks must be ordered separately.

18

Enterprise Virtual Array Hardware Configuration Guide

Enterprise Virtual Array Hardware

The 2C12D configuration can contain a maximum of 6.1 TB (168 36.4-GB disks), 12.2 TB (168 72.8-GB disks), or 24.5 TB (168 146-GB disks) of storage capacity.
Note: The 2C12D configuration can be expanded to increase storage capacity. However, there is a limit to expansion; each controller pair can support a maximum of 240 disks.

Figure 4 shows the 2C12D configuration.


1 2 3 FC drive enclosure FC loop switch Controller pair

2 3 2

CXO7875B

Figure 4: 2C12D configurationrear view

8C8D Features
The following features are included with the 8C8D configuration:

One storage rack Eight controllers Eight 14-drive bay FC drive enclosures Thirty-two internal Fibre Channel cables Seven 2-port enclosure address bus junction boxes Eight AC strips Two 0U PDUs

Enterprise Virtual Array Hardware Configuration Guide

19

Enterprise Virtual Array Hardware

Note: Disks must be ordered separately.

The 8C8D configuration can contain a maximum of 4.1 TB (112 36.4-GB disks), 8.2 TB (112 72.8-GB disks), or 16.4 TB (112 146-GB disks) of storage capacity. Figure 5 shows the 8C8D configuration.
1 2 Controller pair FC drive enclosure

1 2

1 2

CXO7876B

Figure 5: 8C8D configurationrear view

2C2D Features
The following features are included in the 2C2D configuration:

One 41U storage rack Two controllers Two 14-drive bay FC drive enclosures Eight internal Fibre Channel cables Seven 2-port enclosure address bus junction boxes Eight AC strips Two 0U PDUs

Note: Disks must be ordered separately.

20

Enterprise Virtual Array Hardware Configuration Guide

Enterprise Virtual Array Hardware

The 2C2D configuration can contain a maximum of 1.0 TB (28 36.4-GB disks), 2.0 TB (28 72.8-GB disks), or 4.1 TB (28 146-GB disks) of storage capacity. You can expand the storage capacity of the 2C2D configuration by adding drive enclosures and FC loop switches to the rack. Figure 6 shows the front and rear views of the 2C2D configuration.
Front Rear
1 2 3 FC drive enclosure Controller pair Blank

1 2 3

1 3 2

41U

CXO8039B

Figure 6: 2C2D configurationfront and rear views

0C6D Features
The following features are included with the 0C6D configuration:

One storage rack Six 14-drive bay FC drive enclosures Twelve 5-meter rack-to-rack Fibre Channel cables Six 2-port enclosure address bus junction boxes Eight AC strips Two 0U PDUs

Note: Disks must be ordered separately.

Enterprise Virtual Array Hardware Configuration Guide

21

Enterprise Virtual Array Hardware

The 0C6D configuration can add a maximum of 2.6 TB (72 36.4-GB disks), 5.2 TB (72 72.8-GB disks), or 10.5 TB (72 146-GB disks) of storage capacity to an existing Enterprise Virtual Array. If the 0C6D is added to a 2C12D, the Enterprise storage system storage capacity would increase to 8.7 TB (240 36.4-GB disks), 17.5 TB (240 72.8-GB disks), or 35 TB (240 146-GB disks). Figure 7 shows the rear view of the 0C6D configuration.
1 2 3U blank FC drive enclosure

CXO7877A

Figure 7: 0C6D configurationrear view

0C12D Features
The following features are included with the 0C12D configuration:

One storage rack Twelve 14-drive bay FC drive enclosures Twenty-four 5-meter rack-to-rack Fibre Channel cables Six 2-port enclosure address bus junction boxes Eight AC strips Two 0U PDUs

Note: Disks must be ordered separately.

22

Enterprise Virtual Array Hardware Configuration Guide

Enterprise Virtual Array Hardware

The 0C12D configuration can add a maximum of 5.2 TB (144 36.4-GB disks), 10.5 TB (144 72.8-GB disks), or 21 TB (144 146-GB disks) of storage capacity. Typically, this storage capacity is evenly divided between two 2C12D Enterprise storage systems. If you add the 0C12D to two 2C12Ds, the storage capacity for each 2C12D would increase to a maximum of 8.7 TB (240 36.4-GB disks), 17.5 TB (240 72.8-GB disks), or 35 TB (240 146-GB disks). Figure 8 shows the rear view of the 0C12D configuration.
1 2 FC drive enclosure 3U blank

CXO7881A

Figure 8: 0C12D configurationrear view

Enterprise Virtual Array Hardware Configuration Guide

23

Enterprise Virtual Array Hardware

Fibre Channel Drive Enclosures


Each FC drive enclosure includes the following features:

3U drive enclosure Dual redundant, active-to-active, 2-Gbps Fibre Channel loops Fourteen 1-inch Fibre Channel disks per enclosure Environmental Monitor Unit Dual 2-Gbps Fibre Channel I/O moduleA and B Enhanced fault detection Single GBIC

Dual 500-W redundant hot-plug power supplies and fans

For ease of reference, the disk drives are usually referred to by their physical location, the drive bay number. Figure 9 shows the front and rear views of the FC drive enclosure and the physical location of each drive bay.
1 2 3 4 5 6 7 8 9 Drive bay 1 Drive bay 14 EMU I/O module B Blower 1 Power supply 1 Blower 2 Power supply 2 I/O module A CAB Only (enclosure address bus port)

Front

Rear

10 3 4 6 5 8 7 9
CXO7882B

Figure 9: FC drive enclosurefront and rear views

24

Enterprise Virtual Array Hardware Configuration Guide

Enterprise Virtual Array Hardware

HSV110 Controllers
One high performance controller is contained in a controller enclosure. The controller is the interface between HP StorageWorks Command View EVA and a storage system. A storage system is composed of one controller pair and multiple drive enclosures. The Enterprise Virtual Array can contain two HSV110 controllers. Each HSV110 controller features:

High performance power PC microprocessor An Operator Control Panel (OCP) for easy operation Two 2-Gbps Fibre Channel-Switch Fabric host ports Four 2 Gbps FC-AL device ports Arranged in redundant pairs Data load/performance is balanced across a pair Support up to 240 disks per controller pair

1-GB cache per controller, mirrored, with battery backup 2-Gbps FC cache mirroring port with device ports backups Dual power supplies

The HSV110 controller has been modified to contain dual power supplies. The dual power supplies allow the controller to efficiently use power from two power sources. In the event of a single power supply failure, the remaining power supply provides the required power to the controller. Figure 10 shows the front and rear views of the HSV110 controller.
2
1 2 3 4 5 6 7 8 9 10 ; Bezel OCP HF1 port HF2 port Mirror port 1B port 2B port 1A port 2A port Power input CAB (enclosure address bus port)

Front

Rear

11

9
CXO8040B

Figure 10: HSV110 controllerfront and rear views

Enterprise Virtual Array Hardware Configuration Guide

25

Enterprise Virtual Array Hardware

Fibre Channel Loop Switches


The Enterprise Virtual Array v3.0 uses four FC loop switches to connect all of the drive enclosures to the controller pair via Fibre Channel cables. Each FC loop switch acts as a central point of interconnection and establishes a fault-tolerant physical loop topology. The major features of the FC loop switch are:

2.125-Gbps operating speed Twelve ports Half-width, 1U size System and port status LED indicators Universal power supply that operates between 100 to 250 VAC (or 50 to 60 Hz) Small Form-factor Profile (SFP) transceivers
SFP Status LED Port Bypassed LED POST Fault LED Over Temp LED Power LED Loop Operational LED

Figure 11 shows the front and rear views of the Fibre Channel loop switch.
Bezel

Front

1 2 3 4 5 6

Rear

5
CXO7884A

Figure 11: FC loop switchfront and rear views

26

Enterprise Virtual Array Hardware Configuration Guide

Enterprise Virtual Array Hardware

Fibre Channel Cables


When an Enterprise Virtual Array is installed in the SAN, an SCtoLC (1-Gb to 2-Gb) cable is required for host connectivity. Furthermore, the Enterprise Virtual Array uses 2-meter LCtoLC FC cables between the FC loop switches and the FC drive enclosures. Table 2 and Table 3 provide a listing of available FC cables.
Table 2: LC-SC cables Length 2.0 m (40 mm) 5.0 m (80 mm) 15.0 m (150 mm) 30.0 m (300 mm) 50.0 m (500 mm) Table 3: LC-LC Cables Length 2.0 m (40 mm) 5.0 m (80 mm) 15.0 m (150 mm) 30.0 m (300 mm) 50.0 m (500 mm) Description 2-meter LC-LC Multi-Mode Fibre Cable 5-meter LC-LC Multi-Mode Fibre Cable 15-meter LC-LC Multi-Mode Fibre Cable 30-meter LC-LC Multi-Mode Fibre Cable 50-meter LC-LC Multi-Mode Fibre Cable Description CA ASSY, LC-SC, Optical 2M CA ASSY, LC-SC, Optical 5M CA ASSY, LC-SC, Optical 15M CA-ASSY, LC-SC, Optical 30M CA-ASSY, LC-SC, Optical 50M

Enterprise Virtual Array Hardware Configuration Guide

27

Enterprise Virtual Array Hardware

28

Enterprise Virtual Array Hardware Configuration Guide

Enterprise Virtual Array Configurations

This chapter briefly discusses various Enterprise Virtual Array configurations. Each section describes the placement of controllers, drive enclosures, FC loop switches, enclosure address bus junction boxes and cables, and Fibre Channel cables. This chapter contains the following sections:

2C12D Configuration, page 30 2C6D Configuration, page 41 8C8D Configuration, page 51 2C2D Configuration, page 57 2C12D + 0C6D Configuration, page 63 2 x 2C12D + 0C12D Configuration, page 73

Enterprise Virtual Array Hardware Configuration Guide

29

Enterprise Virtual Array Configurations

2C12D Configuration
The 2C12D configuration is a single-rack configuration that provides a maximum of 6.1 TB (168 36.4-GB disks), 12.2 TB (168 72.8-GB disks), or 24.5 TB (168 146-GB disks) of storage capacity. This configuration can contain a maximum of 168 disks. The 2C12D configuration is available in either the 41U rack or the 42U rack. The 2C12D can contain four FC loop switches or one expansion panel.

Enclosure Address Bus Configuration


The 2C12D configuration contains seven enclosure address bus junction boxes at 6U increments in the left rear rail of the rack. The FC drive enclosures and controller pair in the 2C12D configuration use all seven enclosure address bus junction boxes. Each FC drive enclosure should be connected to an enclosure address bus junction box. The FC drive enclosures connect to each enclosure address bus junction box in pairs. The controller pair connects to the enclosure address bus junction box with a Y cable. Figure 12 shows the enclosure address bus cable configuration for the 2C12D configuration.
7 6
1 2 3 4 5 6 7 Bottom terminator Enclosure address 1 Enclosure address bus cable Enclosure address 7 Enclosure address bus junction box Enclosure address 13 Top terminator

5 4 3

2 1
CXO7885C

Figure 12: 2C12D configurationenclosure address bus cables

30

Enterprise Virtual Array Hardware Configuration Guide

Enterprise Virtual Array Configurations

Fibre Channel Loop Configurations


The 2C12D configuration contains four Fibre Channel loops. A Fibre Channel loop is formed when the FC drive enclosures and the controller pair are connected by Fibre Channel cables. The 2C12D configuration can use an FC loop switch or an expansion panel to achieve the desired Fibre Channel loop configuration. When a configuration uses FC loop switches, each FC drive enclosure in a loop is directly connected to the associated FC loop switch. The controller pair is also connected directly to the associated FC loop switch. When the FC loop switch is powered on, it completes a Fibre Channel loop. When a configuration uses an expansion panel, a Fibre Channel loop is achieved by connecting two FC drive enclosures directly to the controllers and linking each FC drive enclosure together in a chain. Table 4 provides the locations for the Fibre Channel loops in a storage rack.
Table 4: Fibre Channel Loop Locations in Rack Fibre Channel Loop
1A 1B 2A 2B

Location in Rack (viewed from rear)


lower right side lower left side upper right side upper left side

Figure 13, Figure 14, Figure 15, and Figure 16 show the 2C12D Fibre Channel loop configurations with the FC loop switches. Figure 17, Figure 18, Figure 19, and Figure 20 show the 2C12D Fibre Channel loop configurations with expansion panels.

Enterprise Virtual Array Hardware Configuration Guide

31

Enterprise Virtual Array Configurations

Figure 13 shows Fibre Channel loop 1A and the associated FC loop switch.
1 2 3 4 5 Controller-to-controller Mirror port FC cable Controller pair FC loop switch FC drive enclosure Fibre Channel cable

2 3 4 5

CXO7886B

Figure 13: 2C12D configurationFibre Channel loop 1A with FC loop switch

32

Enterprise Virtual Array Hardware Configuration Guide

Enterprise Virtual Array Configurations

Figure 14 shows Fibre Channel loop 1B and the associated FC loop switch.
1 2 3 4 5 Controller pair Controller-to-controller Mirror port FC cable FC loop switch FC drive enclosure Fibre Channel cable

2 3 4 5

CXO7887B

Figure 14: 2C12D configurationFibre Channel loop 1B with FC loop switch

Enterprise Virtual Array Hardware Configuration Guide

33

Enterprise Virtual Array Configurations

Figure 15 shows Fibre Channel loop 2A and the associated FC loop switch.
1 2 3 4 5 FC drive enclosure Fibre Channel cable FC loop switch Controller pair Controller-to-controller Mirror port FC cable

3 5 4

CXO7888B

Figure 15: 2C12D configurationFibre Channel loop 2A with FC loop switch

34

Enterprise Virtual Array Hardware Configuration Guide

Enterprise Virtual Array Configurations

Figure 16 shows Fibre Channel loop 2B and the associated FC loop switch.
1 2 3 4 5 Fibre Channel cable FC loop switch Controller-to-controller Mirror port FC cable FC drive enclosure Controller pair

2 5 3

CXO7889B

Figure 16: 2C12D configurationFibre Channel loop 2B with FC loop switch

Enterprise Virtual Array Hardware Configuration Guide

35

Enterprise Virtual Array Configurations

Figure 17 shows Fibre Channel loop 1A in the 42U rack with the expansion panel.
1 2 3 4 Controller pair Expansion panel Fibre Channel cable FC drive enclosure

2 1
IN

1B
OUT IN

2B
OUT IN

1A
OUT IN

2A
OUT

CXO7825B

Figure 17: 2C12D configurationFibre Channel loop 1A with expansion panel

36

Enterprise Virtual Array Hardware Configuration Guide

Enterprise Virtual Array Configurations

Figure 18 shows Fibre Channel loop 1B in the 42U rack with the expansion panel.
1 2 3 4 Controller pair Expansion panel Fibre Channel cable FC drive enclosure

2 1
1B
IN OUT IN

2B
OUT

1A
IN OUT IN

2A
OUT

4 3

CXO7826B

Figure 18: 2C12D configurationFibre Channel loop 1B with expansion panel

Enterprise Virtual Array Hardware Configuration Guide

37

Enterprise Virtual Array Configurations

Figure 19 shows Fibre Channel loop 2A in the 42U rack with the expansion panel.
1 2 3 4 Controller pair FC drive enclosure Fibre Channel cable Expansion panel

1
1B 2B
IN OUT IN

1A
OUT IN

2A
OUT

IN

OUT

CXO7827B

Figure 19: 2C12D configurationFibre Channel loop 2A with expansion panel

38

Enterprise Virtual Array Hardware Configuration Guide

Enterprise Virtual Array Configurations

Figure 20 shows Fibre Channel loop 2B in the 42U rack with the expansion panel.
1 2 3 4 Fibre Channel cable Controller pair FC drive enclosure Expansion panel

3 1

4 2
1B
IN OUT IN

2B
OUT IN

1A
OUT IN

2A
OUT

CXO7828B

Figure 20: 2C12D configurationFibre Channel loop 2B with expansion panel

Cable Management Configurations


A configuration can have two different cable management configurations. If the configuration uses FC loop switches, the configuration uses a combination of cable containment spools and a cable management arm to organize the Fibre Channel cables. If the configuration uses expansion panels, the configuration uses cable containment spools to organize the Fibre Channel cables.

Cable Management Arms


When the configuration uses FC loop switches, the configuration contains two cable management arms. All of the Fibre Channel cables in the configuration pass through one of the cable management arms. Each cable management arm can hold several radial clips. Each radial clip can hold a maximum of seven Fibre Channel cables. The cable management arms can hold all of the Fibre Channel cables within a storage system configuration. Each rack contains four flumes. These flumes are placed next to the cable management arms on the left and right sides of the rack. Each flume guides the Fibre Channel cables from the cable containment spools to the cable management arms.

Enterprise Virtual Array Hardware Configuration Guide

39

Enterprise Virtual Array Configurations

Cable Containment Spools


The cable containment spools hold the Fibre Channel cables. These cable containment spools gather up extra cable length and guide the Fibre Channel cables from the FC drive enclosures to the flumes located on the sides of the rack. The number of cable containment spools varies by rack configuration. Racks with more FC drive enclosures contain more cable containment spools. The 2C12D configuration contains 12 cable containment spools and two cable management arms. Figure 21 shows the cable management configuration for the 2C12D configuration.
1 2 3 4 Cable containment spool Fibre Channel cable Cable management arm Radial clip

1 2

3 4

CXO7901B

Figure 21: 2C12D cable management configuration

40

Enterprise Virtual Array Hardware Configuration Guide

Enterprise Virtual Array Configurations

2C6D Configuration
The 2C6D configuration is a single-rack configuration that provides a maximum of 3.1 TB (84 36.4-GB disks), 6.1 TB (84 72.8-GB disks), or 12.3 TB (84 146-GB disks) of storage capacity. This configuration can contain a maximum of 84 disks. The 2C6D configuration is available in either the 41U rack or the 42U rack. The 2C6D can contain four FC loop switches or one expansion panel.

Enclosure Address Bus Configuration


The 2C6D configuration contains seven enclosure address bus junction boxes at 6U increments in the left rear rail of the rack. Each FC drive enclosure should be connected to an enclosure address bus junction box. The FC drive enclosures connect to each enclosure address bus junction box in pairs. The controller pair connects to the enclosure address bus junction box with a Y cable. Figure 22 shows the enclosure address bus cable configuration for the 2C6D configuration.
1
1 2 3 4 5 6 7 Top terminator Enclosure address bus cable Enclosure address 10 Enclosure address bus junction box Enclosure address 7 Enclosure address 1 Bottom terminator

4 5

6 7
CXO7902C

Figure 22: 2C6D configurationenclosure address bus cables

Enterprise Virtual Array Hardware Configuration Guide

41

Enterprise Virtual Array Configurations

Fibre Channel Loop Configurations


The 2C6D configuration contains four Fibre Channel loops. A Fibre Channel loop is formed when the FC drive enclosures and the controller pair are connected by Fibre Channel cables. The 2C6D configuration can use an FC loop switch or an expansion panel to achieve the desired Fibre Channel loop configuration. (Refer to Fibre Channel Loop Configurations on page 31 for more information about the use of FC loop switches and expansion panels in the FC loop configurations.) Refer to Table 4 on page 31 for the locations of the Fibre Channel loops in a storage rack. Figure 23, Figure 24, Figure 25, and Figure 26 show the 2C6D Fibre Channel loop configurations with the FC loop switches. Figure 27, Figure 28, Figure 29, and Figure 30 show the 2C6D Fibre Channel loop configurations with an expansion panel. Figure 23 shows Fibre Channel loop 1A and the associated FC loop switch.
1 2 3 4 5 Controller-to-controller Mirror port FC cable Controller pair FC loop switch FC drive enclosure Fibre Channel cable

2 3

4 5

CXO7903B

Figure 23: 2C6D configurationFibre Channel loop 1A with FC loop switch

42

Enterprise Virtual Array Hardware Configuration Guide

Enterprise Virtual Array Configurations

Figure 24 shows Fibre Channel loop 1B and the associated FC loop switch.
1 2 3 4 5 Controller-to-controller Mirror port FC cable FC loop switch Fibre Channel cable FC drive enclosure Controller pair

4 1 2 3 5

CXO7904B

Figure 24: 2C6D configurationFibre Channel loop 1B with FC loop switch

Enterprise Virtual Array Hardware Configuration Guide

43

Enterprise Virtual Array Configurations

Figure 25 shows Fibre Channel loop 2A and the associated FC loop switch.
1 2 3 4 5 Fibre Channel cable FC loop switch Controller-to-controller Mirror port FC cable FC drive enclosure Controller pair

2 5 3

CXO7905B

Figure 25: 2C6D configurationFibre Channel loop 2A with FC loop switch

44

Enterprise Virtual Array Hardware Configuration Guide

Enterprise Virtual Array Configurations

Figure 26 shows Fibre Channel loop 2B and the associated FC loop switch.
1 2 3 4 5 FC drive enclosure Fibre Channel cable FC loop switch Controller pair Controller-to-controller Mirror port FC cable

1 2

4 5

CXO7906B

Figure 26: 2C6D configurationFibre Channel loop 2B with FC loop switch

Enterprise Virtual Array Hardware Configuration Guide

45

Enterprise Virtual Array Configurations

Figure 27 shows Fibre Channel loop 1A in the 42U rack with the expansion panel.
1 2 Controller pair Expansion panel

2 1
1B
IN OUT IN

2B
OUT IN

1A
OUT IN

2A
OUT

CXO7907A

Figure 27: 2C6D configurationFibre Channel loop 1A with expansion panel

46

Enterprise Virtual Array Hardware Configuration Guide

Enterprise Virtual Array Configurations

Figure 28 shows Fibre Channel loop 1B in the 42U rack with the expansion panel.
1 2 Controller pair Expansion panel

2 1
1B
IN OUT IN

2B
OUT

1A
IN OUT IN

2A
OUT

CXO7908A

Figure 28: 2C6D configurationFibre Channel loop 1B with expansion panel

Enterprise Virtual Array Hardware Configuration Guide

47

Enterprise Virtual Array Configurations

Figure 29 shows Fibre Channel loop 2A in the 42U rack with the expansion panel.
1 2 Controller pair Expansion panel

1
1B
IN OUT IN

2B
OUT IN

1A
OUT IN

2A
OUT

CXO7909A

Figure 29: 2C6D configurationFibre Channel loop 2A with expansion panel

48

Enterprise Virtual Array Hardware Configuration Guide

Enterprise Virtual Array Configurations

Figure 30 shows Fibre Channel loop 2B in the 42U rack with the expansion panel.
1 2 Controller pair Expansion panel

2 1
1B
IN OUT IN

2B
OUT IN

1A
OUT IN

2A
OUT

CXO7910A

Figure 30: 2C6D configurationFibre Channel loop 2B with expansion panel

Enterprise Virtual Array Hardware Configuration Guide

49

Enterprise Virtual Array Configurations

Cable Management Configurations


The 2C6D configuration contains six cable containment spools and two cable management arms. Please see Cable Management Configurations on page 39 for more information about cable containment spools and cable management arms. Figure 31 shows the cable management configuration in the 2C6D configuration.
1 2 3 4 Cable containment spool Fibre Channel cable Cable management arm Radial clip

1 2

3 4

CXO7911B

Figure 31: 2C6D cable management configuration

50

Enterprise Virtual Array Hardware Configuration Guide

Enterprise Virtual Array Configurations

8C8D Configuration
The 8C8D configuration is a single-rack configuration that provides a maximum of 4.1 TB (112 36.4-GB disks), 8.2 TB (112 72.8-GB disks), or 16.4 TB (112 146-GB disks) of storage capacity. This configuration can contain a maximum of 112 disks. The 8C8D configuration is available in either the 41U rack or the 42U rack.

Enclosure Address Bus Configuration


The 8C8D configuration contains seven enclosure address bus junction boxes at 6U increments in the left rear rail of the rack. Each FC drive enclosure should be connected to an enclosure address bus junction box. The FC drive enclosures connect to each enclosure address bus junction box in pairs. The controller pairs connect to the enclosure address bus junction boxes with a Y cable. Figure 32 shows the enclosure address bus cable configuration for the 8C8D configuration.
1
1 2 3 4 5 Terminator Enclosure address 1 Enclosure address 3 Enclosure address bus junction box Enclosure address bus cable

2 1
CXO7912B

Figure 32: 8C8D configurationenclosure address bus cables

Enterprise Virtual Array Hardware Configuration Guide

51

Enterprise Virtual Array Configurations

Fibre Channel Loop Configurations


The 8C8D configuration contains 16 Fibre Channel loops. A Fibre Channel loop is formed when the FC drive enclosures and the controller pair are connected by Fibre Channel cables. The 8C8D configuration does not use FC loop switches or expansion panels. Instead, each I/O port on an FC drive enclosure is connected directly to a controller with a Fibre Channel cable. Figure 33 shows the four 1A Fibre Channel loops.
1 2 3 Controller pair FC drive enclosure Fibre Channel cable

2 1 3

3 3

CXO7913B

Figure 33: 8C8D configurationFibre Channel loop 1A

52

Enterprise Virtual Array Hardware Configuration Guide

Enterprise Virtual Array Configurations

Figure 34 shows the four 1B Fibre Channel loops.


1 2 3 Controller pair FC drive enclosure Fibre Channel cable

1 3 2 3 3

CXO7914B

Figure 34: 8C8D configurationFibre Channel loop 1B

Enterprise Virtual Array Hardware Configuration Guide

53

Enterprise Virtual Array Configurations

Figure 35 shows the four 2A Fibre Channel loops.


1 2 3 Controller pair FC drive enclosure Fibre Channel cable

1 2

1 2 3 3

CXO7915B

Figure 35: 8C8D configurationFibre Channel loop 2A

54

Enterprise Virtual Array Hardware Configuration Guide

Enterprise Virtual Array Configurations

Figure 36 shows the four 2B Fibre Channel loops.


1 2 3 Controller pair FC drive enclosure Fibre Channel cable

1 3

2 3
CXO7916B

Figure 36: 8C8D configurationFibre Channel loop 2B

Enterprise Virtual Array Hardware Configuration Guide

55

Enterprise Virtual Array Configurations

Cable Management Configurations


The 8C8D configuration contains eight cable containment spools and no cable management arms. Please see Cable Management Configurations on page 39 for more information about cable containment spools and cable management arms. Figure 37 shows the cable management configuration in the 8C8D configuration.
1 2 Cable containment spool Fibre Channel cable

CXO7917B

Figure 37: 8C8D cable management configuration

56

Enterprise Virtual Array Hardware Configuration Guide

Enterprise Virtual Array Configurations

2C2D Configuration
The 2C2D configuration is a single-rack configuration that provides a maximum of 1.0 TB (28 36.4-GB disks), 2.0 TB (28 72.8-GB disks), or 4.1 TB (28 146-GB disks) of storage capacity. This configuration can contain a maximum of 28 disks. You can expand the capacity of the 2C2D configuration by adding more drive enclosures and four FC loop switches. The 2C2D configuration is available in the 41U rack.

Enclosure Address Bus Configuration


The 2C2D configuration contains seven enclosure address bus junction boxes at 6U increments in the left rear rail of the rack. Each FC drive enclosure should be connected to an enclosure address bus junction box. The FC drive enclosures connect to each enclosure address bus junction box in pairs. The controller pair connects to the enclosure address bus junction boxes with a Y cable. Figure 38 shows the enclosure address bus cable configuration for the 2C2D configuration.
6
1 2 3 4 5 6 Bottom terminator Enclosure address 1 Enclosure address bus cable Enclosure address 7 Enclosure address junction box Top terminator

3 2 1
CXO8041C

Figure 38: 2C2D configurationenclosure address bus cables

Enterprise Virtual Array Hardware Configuration Guide

57

Enterprise Virtual Array Configurations

Fibre Channel Loop Configurations


The 2C2D configuration contains four Fibre Channel loops. A Fibre Channel loop is formed when the FC drive enclosures and the controller pair are connected by Fibre Channel cables. The 2C2D configuration does not use FC loop switches or expansion panels. Instead, each I/O port on an FC drive enclosure is connected directly to a controller with a Fibre Channel cable. Refer to Table 4 on page 31 for the locations of the Fibre Channel loops in a storage rack. Figure 39 shows Fibre Channel loop 1A.
1 2 3 4 Controller-to-controller Mirror port FC cable HSV110 controller pair FC drive enclosure Fibre Channel cable

1 4

3
CXO8042B

Figure 39: 2C2D configurationFibre Channel loop 1A

58

Enterprise Virtual Array Hardware Configuration Guide

Enterprise Virtual Array Configurations

Figure 40 shows Fibre Channel loop 1B.


1 2 3 4 Controller-to-controller Mirror port FC cable HSV110 controller pair FC drive enclosure Fibre Channel cable

3
CXO8043B

Figure 40: 2C2D configurationFibre Channel loop 1B

Enterprise Virtual Array Hardware Configuration Guide

59

Enterprise Virtual Array Configurations

Figure 41 shows Fibre Channel loop 2A.


1 2 3 4 Controller-to-controller Mirror port FC cable HSV110 controller pair FC drive enclosure Fibre Channel cable

3 2 1 4

CXO8044B

Figure 41: 2C2D configurationFibre Channel loop 2A

60

Enterprise Virtual Array Hardware Configuration Guide

Enterprise Virtual Array Configurations

Figure 42 shows Fibre Channel loop 2B.


1 2 3 4 Controller-to-controller Mirror port FC cable HSV110 controller pair FC drive enclosure Fibre Channel cable

4 1

CXO8045B

Figure 42: 2C2D configurationFibre Channel loop 2B

Enterprise Virtual Array Hardware Configuration Guide

61

Enterprise Virtual Array Configurations

Cable Management Configurations


The 2C2D configuration contains four cable containment spools and no cable management arms. Please see Cable Management Configurations on page 39 for more information about cable containment spools and cable management arms. Figure 43 shows the cable management configuration for the 2C2D configuration.
1 2 Cable containment spool Fibre Channel cable

2 1

CXO8046A

Figure 43: 2C2D cable management configuration

62

Enterprise Virtual Array Hardware Configuration Guide

Enterprise Virtual Array Configurations

2C12D + 0C6D Configuration


The 2C12D + 0C6D configuration is a dual-rack configuration that provides up to 8.7 TB (240 36.4-GB disks), 17.5 TB (240 72.8-GB disks), or 35 TB (240 146-GB disks) of storage capacity by expanding from 168 disks to 240 disks. The 0C6D rack connects to the 2C12D rack with enclosure address bus cables and Fibre Channel cables.

Enclosure Address Bus Configuration


Each rack contains enclosure address bus junction boxes at 6U increments in the left rear rail of the rack. The 0C6D rack contains six enclosure address bus junction boxes; however, the FC drive enclosures use only three of the enclosure address bus junction boxes. The 2C12D rack contains seven enclosure address bus junction boxes. The FC drive enclosures and controller pair in the 2C12D rack use all seven enclosure address bus junction boxes. The two racks are connected by one enclosure address bus cable, which connects to the bottom enclosure address bus junction box on each rack. The enclosure address bus cable between the racks is polarized. The P1 end of the cable connects to the bottom enclosure address bus junction box on the 2C12D rack. The P2 end of the cable connects to the bottom enclosure address bus junction box on the 0C6D rack.
Note: Make sure the P1 end of the enclosure address bus cable is plugged into the 2C12D rack and the P2 end of the enclosure address bus cable is plugged into the 0C6D rack. If the cable is connected to the racks incorrectly, Command View EVA places the FC drive enclosures in the Unmappable Hardware folder.

In order to connect two racks with an enclosure address bus cable, the HP Authorized Service Representative will have to remove the bottom terminator on the master rack (2C12D rack).

Enterprise Virtual Array Hardware Configuration Guide

63

Enterprise Virtual Array Configurations

Figure 44 shows the enclosure address bus cable configuration in the 2C12D + 0C6D configuration.
1
1 2 Top terminator Enclosure address bus junction box Enclosure address 07 Enclosure address bus cable Enclosure address 01 P1 end of rack-to-rack enclosure address bus cable 5-meter rack-to-rack enclosure address bus cable P2 end of rack-to-rack enclosure address bus cable Enclosure address 17

3 4

5 6

2 3 1
8 7

4 9
9

5 8 7
CXO7918C

Figure 44: 2C12D + 0C6D configurationenclosure address bus cables

Fibre Channel Loop Configurations


The 2C12D + 0C6D configuration contains four Fibre Channel loops. A Fibre Channel loop is formed when the FC drive enclosures and the controller pair are connected by Fibre Channel cables. The 2C12D configuration can use an FC loop switch or expansion panels to achieve the desired Fibre Channel loop configuration. When the 2C12D + 0C6D configuration uses FC loop switches, each FC drive enclosure in a loop is directly connected to the associated FC loop switch. The controller pair is also connected directly to the associated FC loop switch. When the FC loop switch is powered on, it completes a Fibre Channel loop. When the 2C12D + 0C6D configuration uses expansion panels, all of the FC drive enclosures in a loop are connected to the controller pair in the master rack. The 2C12D + 0C6D configuration uses expansion panels to achieve this configuration. Refer to Table 4 on page 31 for locations of Fibre Channel loops in a storage rack.

64

Enterprise Virtual Array Hardware Configuration Guide

Enterprise Virtual Array Configurations

Figure 45 shows Fibre Channel loop 1A and the associated FC loop switch.
1 2 3 4 5 Controller-to-controller Mirror port FC cable Controller pair FC loop switch FC drive enclosure Fibre Channel cable

1 2 3 4 5

CXO7919B

Figure 45: 2C12D + 0C6D configurationFibre Channel loop 1A with FC loop switch

Enterprise Virtual Array Hardware Configuration Guide

65

Enterprise Virtual Array Configurations

Figure 46 shows Fibre Channel loop 1B and the associated FC loop switch.
1 2 3 4 5 Controller pair Controller-to-controller Mirror port FC cable FC loop switch FC drive enclosure Fibre Channel cable

2 3 4 5

CXO7920B

Figure 46: 2C12D + 0C6D configurationFibre Channel loop 1B with FC loop switch

66

Enterprise Virtual Array Hardware Configuration Guide

Enterprise Virtual Array Configurations

Figure 47 shows Fibre Channel loop 2A and the associated FC loop switch.
1 2 3 4 5 FC drive enclosure Fibre Channel cable FC loop switch Controller pair Controller-to-controller Mirror port FC cable

3 5 4

CXO7921B

Figure 47: 2C12D + 0C6D configurationFibre Channel loop 2A with FC loop switch

Enterprise Virtual Array Hardware Configuration Guide

67

Enterprise Virtual Array Configurations

Figure 48 shows Fibre Channel loop 2B and the associated FC loop switch.
1 2 3 4 5 Fibre Channel cable FC loop switch Controller-to-controller Mirror port FC cable FC drive enclosure Controller pair

2 5 3

CXO7922B

Figure 48: 2C12D + 0C6D configurationFibre Channel loop 2B with FC loop switch

68

Enterprise Virtual Array Hardware Configuration Guide

Enterprise Virtual Array Configurations

Figure 49 shows Fibre Channel loop 1A with expansion panels.

3 2
1B
IN OUT IN

Master 2B
OUT IN

1A
OUT IN

2A
OUT

4
1B
IN OUT IN

7
2A
IN OUT

2B
OUT IN

1A
OUT

Expansion

5 7

CXO7813B

1 2 3 4 5 6 7

Master rack Controller pair Master rack expansion panel 5-meter rack-to-rack Fibre Channel cables Expansion rack expansion panel Expansion rack FC drive enclosure

Figure 49: 2C12D + 0C6D configurationFibre Channel loop 1A with expansion panels

Enterprise Virtual Array Hardware Configuration Guide

69

Enterprise Virtual Array Configurations

Figure 50 shows Fibre Channel Loop 1B with expansion panels.

3 2
1B
IN OUT IN

Master 2B
OUT

1A
IN OUT IN

2A
OUT

4
1B
IN OUT IN

2B
OUT IN

1A
OUT IN

2A
OUT

Expansion

5 7 7

CXO7814B

1 2 3 4 5 6 7

Master rack Controller pair Master rack expansion panel 5-meter rack-to-rack Fibre Channel cables Expansion rack expansion panel Expansion rack FC drive enclosure

Figure 50: 2C12D + 0C6D configurationFibre Channel Loop 1B with expansion panels

70

Enterprise Virtual Array Hardware Configuration Guide

Enterprise Virtual Array Configurations

Figure 51 shows Fibre Channel Loop 2A with expansion panels.

2
1B
IN OUT IN

Master 2B
OUT IN

1A
OUT IN

2A
OUT

3
1B
IN OUT IN

4
2B
OUT IN

1A
OUT IN

2A
OUT

Expansion

5 7 7

CXO7815B

1 2 3 4 5 6 7

Master rack Controller pair Master rack expansion panel 5-meter rack-to-rack Fibre Channel cables Expansion rack expansion panel Expansion rack FC drive enclosure

Figure 51: 2C12D + 0C6D configurationFibre Channel loop 2A with expansion panels

Enterprise Virtual Array Hardware Configuration Guide

71

Enterprise Virtual Array Configurations

Figure 52 shows Fibre Channel Loop 2B with expansion panels.

2
1B
IN OUT IN

Master 2B
OUT IN

3
2A
IN OUT

1A
OUT

4
1B
IN OUT IN

2B
OUT IN

1A
OUT IN

2A
OUT

Expansion

5 7 7
CXO7816B

1 2 3 4 5 6 7

Master rack Controller pair Master rack expansion panel 5-meter rack-to-rack Fibre Channel cables Expansion rack expansion panel Expansion rack FC drive enclosure

Figure 52: 2C12D + 0C6D configurationFibre Channel loop 2B with expansion panels

72

Enterprise Virtual Array Hardware Configuration Guide

Enterprise Virtual Array Configurations

2 x 2C12D + 0C12D Configuration


The 2 x 2C12D + 0C12D configuration is a triple-rack configuration that can provide up to 17.5 TB (480 36.4-GB disks), 34.9 TB (480 72.8-GB disks), or 70 TB (480 146-GB disks) of storage capacity by expanding each Enterprise Virtual Array to 240 disks each for a total of 480 disks. The two 2C12D master racks connect to the 0C12D expansion rack with enclosure address bus and Fibre Channel cables.

Enclosure Address Bus Configuration


Each rack contains enclosure address bus junction boxes at 6U increments in the left rear rail of the rack. The 0C12D rack contains six enclosure address bus junction boxes. The FC drive enclosures in the 0C12D rack use all six enclosure address bus junction boxes. The 2C12D rack contains seven enclosure address bus junction boxes. The FC drive enclosures and controller pair in the 2C12D rack use all seven enclosure address bus junction boxes. The three racks are connected by two enclosure address bus cables. Each master rack is connected to the expansion rack by one enclosure address bus cable. One master rack runs an enclosure address bus cable to the bottom enclosure address bus junction box on the expansion rack; the other master rack runs an enclosure address bus cable to the fourth enclosure address bus junction box (from the bottom) on the expansion rack. The enclosure address bus cables are polarized. The P1 end of the cable connects to the bottom enclosure address bus junction box on the 2C12D rack. The P2 end of the cable connects to the enclosure address bus junction box on the expansion rack.
Note: Make sure the P1 end of the enclosure address bus cable is plugged into the 2C12D rack and the P2 end of the enclosure address bus cable is plugged into the expansion rack. If the cable is connected to the racks incorrectly, Command View EVA places the FC drive enclosures in the Unmappable Hardware folder.

In order to connect the racks with an enclosure address bus cable, the HP Authorized Service Representative will have to remove the bottom terminator on the master racks (2C12D rack).

Enterprise Virtual Array Hardware Configuration Guide

73

Enterprise Virtual Array Configurations

Figure 53 shows the enclosure address bus cable configuration in the 2C12D + 0C12D configuration.
1 1 2 10 1

8 3 7

4 5 6 6
CXO7923C

1 2 3 4 5 6 7 8 9 -

Top terminator Enclosure address bus cable Enclosure address 7 Enclosure address 1 P1 end of rack-to-rack enclosure address bus cable 5-meter rack-to-rack enclosure address bus cable P2 end of rack-to-rack enclosure address bus cable Enclosure address 15 Enclosure address junction box FC drive enclosure

Figure 53: 2 x 2C12D + 0C12D configurationenclosure address bus cables

Fibre Channel Loop Configurations


The 2 x 2C12D + 0C12D configuration contains eight Fibre Channel loops. A Fibre Channel loop is formed when the FC drive enclosures and the controller pair are connected by Fibre Channel cables. The 2 x 2C12D + 0C12D configuration can use an FC loop switch or expansion panels to achieve the desired Fibre Channel loop configuration. The 0C12D rack is divided into an upper and lower half. The upper half of the 0C12D rack connects to the master rack on the right (when viewed from the rear), and the lower half of the 0C12D rack connects to the master rack on the left (when viewed from the rear).
74 Enterprise Virtual Array Hardware Configuration Guide

Enterprise Virtual Array Configurations

When the 2 x 2C12D + 0C12D configuration uses FC loop switches, each FC drive enclosure in a loop is directly connected to the associated FC loop switch. The controller pair is also connected directly to the associated FC loop switch. When the FC loop switch is powered on, it completes a Fibre Channel loop. When the 2 x 2C12D + 0C12D configuration uses expansion panels, all of the FC drive enclosures in a loop are connected to the controller pair in the master rack. The 2 x 2C12D + 0C12D configuration uses expansion panels to achieve this configuration. Refer to Table 4 on page 31 for locations of Fibre Channel loops in a storage rack. Figure 54 shows the two 1A Fibre Channel loops and the associated FC loop switches.

1 2 3 4 5

CXO7924B

1 2 3 4 5

Controller-to-controller Mirror port FC cable Controller pair FC loop switch FC drive enclosure Fibre Channel cable

Figure 54: 2 x 2C12D + 0C12D configurationFibre Channel loop 1A with FC loop switch

Enterprise Virtual Array Hardware Configuration Guide

75

Enterprise Virtual Array Configurations

Figure 55 shows the two 1B Fibre Channel loops and the associated FC loop switches.

1 3 4 5 2

CXO7925B

1 2 3 4 5

Controller pair Controller-to-controller Mirror port FC cable FC loop switch FC drive enclosure Fibre Channel cable

Figure 55: 2 x 2C12D + 0C12D configurationFibre Channel loop 1B with FC loop switch

76

Enterprise Virtual Array Hardware Configuration Guide

Enterprise Virtual Array Configurations

Figure 56 shows the two 2A Fibre Channel loops and the associated FC loop switches.

3 4 5

CXO7926B

1 2 3 4 5

FC drive enclosure Fibre Channel cable FC loop switch Controller pair Controller-to-controller Mirror port FC cable

Figure 56: 2 x 2C12D + 0C12D configurationFibre Channel loop 2A with FC loop switch

Enterprise Virtual Array Hardware Configuration Guide

77

Enterprise Virtual Array Configurations

Figure 57 shows the two 2B Fibre Channel loops and the associated FC loop switches.

1 4

2 5 3

CXO7927B

1 2 3 4 5

Fibre Channel cable FC loop switch Controller-to-controller Mirror port FC cable FC drive enclosure Controller pair

Figure 57: 2 x 2C12D + 0C12D configurationFibre Channel loop 2B with FC loop switch

78

Enterprise Virtual Array Hardware Configuration Guide

Enterprise Virtual Array Configurations

2
1B
IN OUT IN OUT IN OUT IN OUT

Master 2B 1A 2A
IN

Expansion 1B
OUT IN

2
2B
OUT IN

1A
OUT IN

2A
OUT

3
1B
IN OUT IN OUT IN OUT IN

4
2B 1A 2A
OUT IN

5
1B
OUT IN

4
2B
OUT IN

1A
OUT IN

2A
OUT

5 7

Expansion

Master

CXO7818B

1 2 3 4 5 6 7

Master rack Controller pair Master rack expansion panel 5-meter rack-to-rack Fibre Channel cables Expansion rack expansion panel Expansion rack FC drive enclosure

Figure 58: 2 x 2C12D + 0C12D configurationFibre Channel loop 1A with expansion panels

Enterprise Virtual Array Hardware Configuration Guide

79

Figure 58 shows the two 1A Fibre Channel loops with expansion panels.

80

Figure 59 shows the two 1B Fibre Channel loops with expansion panels.
6 1

Enterprise Virtual Array Configurations

2
1B
IN OUT IN OUT IN OUT IN OUT IN OUT IN OUT IN

Master 2B 1A 2A 1B 2B 1A
OUT

Expansion 2A
IN OUT

4 3
2B
IN OUT IN OUT IN OUT IN OUT

4
1B
IN

5
2B
OUT IN

1B
IN OUT

1A

2A

1A
OUT IN

2A
OUT

Expansion

Master

CXO7819B

1 2 3 4 5 6 7

Master rack Controller pair Master rack expansion panel 5-meter rack-to-rack Fibre Channel cables Expansion rack expansion panel Expansion rack FC drive enclosure

Enterprise Virtual Array Hardware Configuration Guide

Figure 59: 2 x 2C12D + 0C12D configurationFibre Channel loop 1B with expansion panels

Enterprise Virtual Array Configurations

2
1B
IN OUT IN OUT IN OUT IN OUT

Master 2B 1A 2A
IN

Expansion 1B
OUT IN

2
2B
OUT IN

1A
OUT IN

2A
OUT

3 4
2B
IN OUT IN

5
2A 1B 2B
IN OUT IN OUT IN OUT IN

4
1A 2A
OUT IN OUT

1B
IN OUT

1A
OUT

5 7

Expansion

Master

CXO7820B

1 2 3 4 5 6 7

Master rack Controller pair Master rack expansion panel 5-meter rack-to-rack Fibre Channel cables Expansion rack expansion panel Expansion rack FC drive enclosure

Figure 60: 2 x 2C12D + 0C12D configurationFibre Channel loop 2A with expansion panels

Enterprise Virtual Array Hardware Configuration Guide

81

Figure 60 shows the two 2A Fibre Channel loops with expansion panels.

82

Figure 61 shows the two 2B Fibre Channel loops with expansion panels.
6 1

Enterprise Virtual Array Configurations

2
1B
IN OUT IN OUT IN OUT IN OUT IN OUT IN OUT IN

Master 2B 1A 2A 1B 2B 1A
OUT

Expansion 2A
IN OUT

3
1B
IN OUT IN OUT IN OUT IN OUT IN OUT

4 5
1A 2A 1B
IN

4
2B
OUT IN

2B

1A
OUT IN

2A
OUT

Expansion

Master

CXO7821B

1 2 3 4 5 6 7

Master rack Controller pair Master rack expansion panel 5-meter rack-to-rack Fibre Channel cables Expansion rack expansion panel Expansion rack FC drive enclosure

Enterprise Virtual Array Hardware Configuration Guide

Figure 61: 2 x 2C12D + 0C12D configurationFibre Channel loop 2B with expansion panels

Upgrading Existing Racks to Enterprise v2.0

This chapter summarizes how to upgrade an Enterprise Virtual Array v1.0 configuration to an Enterprise Virtual Array v2.0 configuration. The key differences between an Enterprise Virtual Array v1.0 configuration and an Enterprise Virtual Array v2.0 configuration are the absence of expansion panels, the addition of FC loop switches, and the reconfiguration of the Fibre Channel cables. This chapter contains the following sections:

Expansion Panels, page 85 FC Loop Switches, page 85 Fibre Channel Cable Reconfiguration, page 85

Note: Only HP Authorized Service Representatives may upgrade Enterprise Virtual Array v1.0 configurations to Enterprise Virtual Array v2.0 configurations.

Before you upgrade an Enterprise Virtual Array v1.0 configuration to an Enterprise Virtual Array v2.0 configuration, ensure that you have the correct Enterprise Virtual Array software and firmware. Refer to HP StorageWorks Enterprise Virtual Array Changing EVA Versions Instructions for more information.

Enterprise Virtual Array Hardware Configuration Guide

83

Upgrading Existing Racks to Enterprise v2.0

Figure 62 shows the 2C12D configuration for the Enterprise Virtual Array v1.0 and the for Enterprise Virtual Array v2.0. In general, v2.0 racks are characterized by the presence of the FC loop switches. Enterprise v1.0 racks are 42U, while v2.0 racks can be either 41U or 42U.
Note: Enterprise Virtual Array v3.0 racks use the same configurations as the Enterprise Virtual Array v2.0 racks.

V1 V2 1 6

5 4 2 4 2 5

CXO7974A

1 2 3 4 5 6

42U rack Controller pair FC drive enclosure Expansion panels FC loop switches 41U rack

Figure 62: Expansion panels versus FC loop switches

84

Enterprise Virtual Array Hardware Configuration Guide

Upgrading Existing Racks to Enterprise v2.0

Expansion Panels
In Version 1.0 of the Enterprise Virtual Array, expansion panels were added to racks to allow you to expand the storage capacity of the Enterprise Virtual Array. In Version 2.0 of the Enterprise Virtual Array, the presence of FC loop switches has made the expansion panels obsolete. You can easily expand an Enterprise Virtual Array configuration by directly connecting additional FC drive enclosures to the FC loop switches. Your HP Authorized Service Representative is responsible for removing expansion panels.

FC Loop Switches
An Enterprise Virtual Array master rack contains four FC loop switches. Typically, two FC loop switches are mounted on a rack shelf above the controller pair, and two FC loop switches are mounted on a rack shelf below the controller pair. Your HP Authorized Service Representative is responsible for installing FC loop switches.

Fibre Channel Cable Reconfiguration


The Fibre Channel cable configuration on a rack that uses FC loop switches differs from the Fibre Channel cable configuration on a rack that uses expansion panels. When a rack uses an expansion panel, the FC drive enclosures are linked together in a chain and connected to the controllers via the expansion panel. When a rack uses FC loop switches, the FC drive enclosures and the controllers are linked directly to the FC loop switch. Your HP Authorized Service Representative is responsible for reconfiguring the Fibre Channel loops.

Enterprise Virtual Array Hardware Configuration Guide

85

Upgrading Existing Racks to Enterprise v2.0

Figure 63 shows the 2C12D Fibre Channel loop 1A configurations for both a v1.0 configuration and a v2.0 configuration.
V1

V2

3 2
IN

2
1B
OUT IN

4 4

2B
OUT IN

1A
OUT IN

2A
OUT

CXO7975A

1 2 3 4 5

42U rack Controller pair Expansion panel FC loop switch 41U rack

Figure 63: Fibre Channel cabling comparison Enterprise v1.0 to Enterprise v2.0

86

Enterprise Virtual Array Hardware Configuration Guide

Expanding a Rack

This chapter summarizes how to add new FC drive enclosures to a storage rack and describes the placement of controllers, FC drive enclosures, FC loop switches, enclosure address bus junction boxes and cables, and Fibre Channel cables. This chapter contains the following sections:

Adding FC Drive Enclosures to a Rack, page 88 2C6D + 6D Configuration, page 89 0C6D + 6D Configuration, page 99

Only HP Authorized Service Representatives may expand the 2C6D and 0C6D racks. The 2C6D and 0C6D racks may be expanded by adding FC drive enclosures, Fibre Channel cables, and enclosure address bus cables to the existing racks. In general, the FC drive enclosures are added in pairs. The 2C6D rack can be expanded to the following:

2C6D + 2D (expands the 2C6D rack to 112 disks) 2C6D + 4D (expands the 2C6D rack to 140 disks) 2C6D + 6D (expands the 2C6D rack to 168 disks)

The 0C6D rack can be expanded to the 0C12D rack.

Enterprise Virtual Array Hardware Configuration Guide

87

Expanding a Rack

Adding FC Drive Enclosures to a Rack


An HP Authorized Service Representative can add FC drive enclosures to a rack while the Enterprise Virtual Array is on or off. HP highly recommends that the Enterprise Virtual Array is turned off, while adding FC drive enclosures to a rack. If the HP Authorized Service Representative would like to add an FC drive enclosure to the rack with the power on, the service representative should take care to disconnect and connect one Fibre Channel loop at a time. Adding FC drive enclosures involves placing the drive enclosures in the rack, connecting the drive enclosures to the enclosure address bus and the power outlets, and correctly adding the drive enclosures to the FC loops.
Note: An HP Authorized Service Representative must add the FC drive enclosures to the rack. Do not attempt to do add an FC drive enclosure without first seeking guidance and assistance from an HP Authorized Service Representative.

2C6D Configuration
The 2C6D configuration contains up to six FC drive enclosures (84 disks). This configuration is shown in Figure 64.
1 2 3 4 3U blank FC drive enclosure FC loop switch Controller pair

3 4 3

CXO7874B

Figure 64: 2C6D configuration

88

Enterprise Virtual Array Hardware Configuration Guide

Expanding a Rack

2C6D + 6D Configuration
The 2C6D + 6D configuration provides up to twelve FC drive enclosures (168 disks). It upgrades a 2C6D configuration to a 2C12D configuration.
Note: This configuration is only available with assistance from an HP Authorized Service Representative.

Enclosure Address Bus Configuration


Each FC drive enclosure should be connected to an enclosure address bus junction box. The FC drive enclosures connect to each enclosure address bus junction box in pairs. The controller pair connects to the enclosure address bus junction box with a Y cable. Figure 65 shows the enclosure address bus cable configuration for the 2C6D + 6D configuration.
7 6
1 2 3 4 5 6 7 Bottom terminator Enclosure address 1 Enclosure address bus cable Enclosure address 7 Enclosure address bus junction box Enclosure address 13 Top terminator

5 4 3

2 1
CXO7885C

Figure 65: 2C6D + 6D configurationenclosure address cables

Enterprise Virtual Array Hardware Configuration Guide

89

Expanding a Rack

Fibre Channel Loop Configurations


The 2C6D + 6D configuration contains four Fibre Channel loops. A Fibre Channel loop is formed when the FC drive enclosures and the controller pair are connected by Fibre Channel cables. The 2C6D + 6D configuration can use an FC loop switch or an expansion panel to achieve the desired Fibre Channel loop configuration. When the 2C6D + 6D configuration uses FC loop switches, each FC drive enclosure in a loop is directly connected to the associated FC loop switch. The controller pair is also connected directly to the associated FC loop switch. When the FC loop switch is powered on, it completes a Fibre Channel loop. When the 2C6D + 6D configuration uses an expansion panel, a Fibre Channel loop is accomplished by connecting two FC drive enclosures directly to the controllers and linking each FC drive enclosure together in a chain. Table 5 provides the locations for the Fibre Channel loops in a storage rack.
Table 5: Fibre Channel Loop Locations in Rack Fibre Channel Loop
1A 1B 2A 2B

Location in Rack (viewed from rear)


lower right side lower left side upper right side upper left side

Figure 66 shows Fibre Channel loop 1A and the associated FC loop switch.

90

Enterprise Virtual Array Hardware Configuration Guide

Expanding a Rack

1 2 3 4 5

Controller-to-controller Mirror port FC cable Controller pair FC loop switch FC drive enclosure Fibre Channel cable

2 3 4 5

CXO7886B

Figure 66: 2C6D + 6D configurationFibre Channel loop 1A with FC loop switch

Enterprise Virtual Array Hardware Configuration Guide

91

Expanding a Rack

Figure 67 shows Fibre Channel loop 1B and the associated FC loop switch.
1 2 3 4 5 Controller pair Controller-to-controller Mirror port FC cable FC loop switch FC drive enclosure Fibre Channel cable

2 3 4 5

CXO7887B

Figure 67: 2C6D + 6D configurationFibre Channel loop 1B with FC loop switch

92

Enterprise Virtual Array Hardware Configuration Guide

Expanding a Rack

Figure 68 shows Fibre Channel loop 2A and the associated FC loop switch.
1 2 3 4 5 FC drive enclosure Fibre Channel cable FC loop switch Controller pair Controller-to-controller Mirror port FC cable

3 5 4

CXO7888B

Figure 68: 2C6D + 6D configurationFibre Channel loop 2A with FC loop switch

Enterprise Virtual Array Hardware Configuration Guide

93

Expanding a Rack

Figure 69 shows Fibre Channel loop 2B and the associated FC loop switch.
1 2 3 4 5 Fibre Channel cable FC loop switch Controller-to-controller Mirror port FC cable FC drive enclosure Controller pair

2 5 3

CXO7889B

Figure 69: 2C6D + 6D configurationFibre Channel loop 2B with FC loop switch

94

Enterprise Virtual Array Hardware Configuration Guide

Expanding a Rack

Figure 70 shows Fibre Channel loop 1A with the expansion panel.


1 2 3 4 Controller pair Expansion panel Fibre Channel cable FC drive enclosure

2 1
IN

1B
OUT IN

2B
OUT IN

1A
OUT IN

2A
OUT

CXO7825B

Figure 70: 2C6D + 6D configurationFibre Channel loop 1A with expansion panel

Enterprise Virtual Array Hardware Configuration Guide

95

Expanding a Rack

Figure 71 shows Fibre Channel loop 1B with an expansion panel.


1 2 Controller pair Expansion panel

2 1
1B
IN OUT IN

2B
OUT

1A
IN OUT IN

2A
OUT

4 3

CXO7826B

Figure 71: 2C6D + 6D configurationFibre Channel loop 1B with expansion panel

96

Enterprise Virtual Array Hardware Configuration Guide

Expanding a Rack

Figure 72 shows Fibre Channel loop 2A with an expansion panel.


1 2 3 4 Controller pair FC drive enclosure Fibre Channel cable Expansion panel

1
1B 2B
IN OUT IN

1A
OUT IN

2A
OUT

IN

OUT

CXO7827B

Figure 72: 2C6D + 6D configurationFibre Channel loop 2A with expansion panel

Enterprise Virtual Array Hardware Configuration Guide

97

Expanding a Rack

Figure 73 shows Fibre Channel loop 2B with an expansion panel.


1 2 3 4 Fibre Channel cable Controller pair FC drive enclosure Expansion panel

3 1

4 2
1B
IN OUT IN

2B
OUT IN

1A
OUT IN

2A
OUT

CXO7828B

Figure 73: 2C6D + 6D configurationFibre Channel loop 2B with expansion panel

98

Enterprise Virtual Array Hardware Configuration Guide

Expanding a Rack

0C6D + 6D Configuration
The 0C6D + 6D configuration can support two controller pairs, and allows each controller pair to support a maximum of 240 disks.

Enclosure Address Bus Configuration


Each FC drive enclosure should be connected to an enclosure address bus junction box. The FC drive enclosures connect to each enclosure address bus junction box in pairs. Figure 74 shows the enclosure address bus cable configuration for the 0C6D + 6D configuration.
1 2 Terminator Enclosure address bus junction box Bottom terminator (This terminator is removed to connect the expansion rack to the master rack.)

3
CXO7933A

Figure 74: 0C6D + 6D configurationenclosure address bus cables

Fibre Channel Loop Configurations


The 0C6D + 6D configuration contains eight Fibre Channel loops. A Fibre Channel loop is formed when the FC drive enclosures and the controller pair are connected by Fibre Channel cables. The 0C6D + 6D configuration can use an FC loop switch or expansion panels to achieve the desired Fibre Channel loop configuration. The 0C6D + 6D rack is divided into an upper and lower half. The upper half of the 0C12D rack connects to one master rack, and the lower half of the 0C12D rack connects to another master rack.

Enterprise Virtual Array Hardware Configuration Guide

99

Expanding a Rack

When the 0C6D + 6D configuration uses FC loop switches, each FC drive enclosure in a loop is directly connected to the associated FC loop switch on the master rack. The controller pair is also connected directly to the associated FC loop switch. When the FC loop switch is powered on, it completes a Fibre Channel loop. When the 0C6D + 6D configuration uses expansion panels, all of the FC drive enclosures in a loop are connected to the controller pair in the master rack. The 0C6D + 6D configuration uses expansion panels to achieve this configuration. Figure 75 shows the two 1A Fibre Channel loops.
1 FC cable

Each FC cable is connected to the 1A FC loop switch in the master rack.


2 FC drive enclosure

CXO7934A

Figure 75: 0C6D + 6D configurationFibre Channel loop 1A

100

Enterprise Virtual Array Hardware Configuration Guide

Expanding a Rack

Figure 76 shows the two 1B Fibre Channel loops.


1 FC cable

Each FC cable is connected to the 1B FC loop switch in the master rack.


2 FC drive enclosure

CXO7935A

Figure 76: 0C6D + 6D configurationFibre Channel loop 1B

Enterprise Virtual Array Hardware Configuration Guide

101

Expanding a Rack

Figure 77 shows the two 2A Fibre Channel loops.


1 FC cable

Each FC cable is connected to the 2A FC loop switch in the master rack.


2 FC drive enclosure

1 2

CXO7936A

Figure 77: 0C6D + 6D configurationFibre Channel loop 2A

102

Enterprise Virtual Array Hardware Configuration Guide

Expanding a Rack

Figure 78 shows the two 2B Fibre Channel loops.


1 FC cable

Each FC cable is connected to the 2B FC loop switch in the master rack.


2 FC drive enclosure

1 2

CXO7937A

Figure 78: 0C6D + 6D configurationFibre Channel loop 2B

Enterprise Virtual Array Hardware Configuration Guide

103

Expanding a Rack

Figure 79 shows the two 1A Fibre Channel loops and the expansion panels.
1 2 Expansion panel 5-meter Fibre Channel cables that connect to the master rack.

2 1
1B
IN OUT IN

2B
OUT IN

1A
OUT IN

2A
OUT

Expansion

1B
IN OUT IN

2B
OUT IN

1A
OUT IN

2A
OUT

Expansion

CXO7830A

Figure 79: 0C6D + 6D configurationFibre Channel loop 1A with expansion panels

104

Enterprise Virtual Array Hardware Configuration Guide

Expanding a Rack

Figure 80 shows the two 1B Fibre Channel loops and the expansion panels.
1 2 Expansion panel 5-meter Fibre Channel cables that connect to the master rack.

2 1
1B
IN OUT IN

2B
OUT IN

1A
OUT IN

2A
OUT

Expansion

1B
IN OUT IN

2B
OUT IN

1A
OUT IN

2A
OUT

Expansion

CXO7831A

Figure 80: 0C6D + 6D configurationFibre Channel loop 1B with expansion panels

Enterprise Virtual Array Hardware Configuration Guide

105

Expanding a Rack

Figure 81 shows the two 2A Fibre Channel loops and the expansion panels.
1 2 Expansion panel 5-meter Fibre Channel cables that connect to the master rack.

2 1
1B
IN OUT IN

2B
OUT IN

1A
OUT IN

2A
OUT

Expansion

1B
IN OUT IN

2B
OUT IN

1A
OUT IN

2A
OUT

Expansion

CXO7832A

Figure 81: 0C6D + 6D configurationFibre Channel loop 2A with expansion panels

106

Enterprise Virtual Array Hardware Configuration Guide

Expanding a Rack

Figure 82 shows the two 2B Fibre Channel loops and the expansion panels.
1 2 Expansion panel 5-meter Fibre Channel cables that connect to the master rack.

2 1
1B
IN OUT IN

2B
OUT IN

1A
OUT IN

2A
OUT

Expansion

1B
IN OUT IN

2B
OUT IN

1A
OUT IN

2A
OUT

Expansion

CXO7833A

Figure 82: 0C6D + 6D configurationFibre Channel loop 2B with expansion panels

Enterprise Virtual Array Hardware Configuration Guide

107

Expanding a Rack

108

Enterprise Virtual Array Hardware Configuration Guide

Regulatory Notices and Specifications

This appendix includes regulatory notices and product specifications for the HP StorageWorks Enterprise Virtual Array. The following topics are included:

Regulatory Notices, page 110 Fibre Channel Drive Enclosure Specifications, page 116 Fibre Channel Switch Specifications, page 120 Controller Specifications, page 121 Enterprise Rack, page 123

Enterprise Virtual Array Hardware Configuration Guide

109

Regulatory Notices and Specifications

Regulatory Notices
Federal Communications Commission Notice
Part 15 of the Federal Communications Commission (FCC) Rules and Regulations has established Radio Frequency (RF) emission limits to provide an interference-free radio frequency spectrum. Many electronic devices, including computers, generate RF energy incidental to their intended function and are, therefore, covered by these rules. These rules place computers and related peripheral devices into two classes, A and B, depending upon their intended installation. Class A devices are those that may reasonably be expected to be installed in a business or commercial environment. Class B devices are those that may reasonably be expected to be installed in a residential environment (for example, personal computers). The FCC requires devices in both classes to bear a label indicating the interference potential of the device as well as additional operating instructions for the user. The rating label on the device shows the classification (A or B) of the equipment. Class B devices have an FCC logo or FCC ID on the label. Class A devices do not have an FCC logo or FCC ID on the label. After the Class of the device is determined, refer to the corresponding statement in the following sections.

FCC Class A Certification


This equipment generates, uses, and may emit radio frequency energy. The equipment has been type tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC rules, which are designed to provide reasonable protection against such radio frequency interference. Operation of this equipment in a residential area may cause interference, in which case the user at the users own expense will be required to take whatever measures may be required to correct the interference. Any modifications to this deviceunless approved by the manufacturercan void the users authority to operate this equipment under Part 15 of the FCC rules.
Note: Additional information on the need to interconnect the device with shielded (data) cables or the need for special devices, such as ferrite beads on cables, is required if such means of interference suppression was used in the qualification test for the device. This information will vary from device to device and needs to be obtained from the HP EMC group.

Class A Equipment
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference, in which case the user will be required to correct the interference at personal expense.

110

Enterprise Virtual Array Hardware Configuration Guide

Regulatory Notices and Specifications

Class B Equipment
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

Reorient or relocate the receiving antenna. Increase the separation between the equipment and receiver. Connect the equipment into an outlet on a circuit that is different from that to which the receiver is connected. Consult the dealer or an experienced radio or television technician for help.

Declaration of Conformity for Products Marked with the FCC Logo, United States Only
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. For questions regarding your product, refer to http://thenew.hp.com. For questions regarding this FCC declaration, contact:

Hewlett-Packard Company Product Regulations Manager 3000 Hanover St. Palo Alto, CA 94304 Or call 1-650-857-1501

To identify this product, refer to the part, series, or model number found on the product.

Modifications
The FCC requires the user to be notified that any changes or modifications made to this device that are not expressly approved by Hewlett-Packard Company may void the user's authority to operate the equipment.

Cables
Connections to this device must be made with shielded cables with metallic RFI/EMI connector hoods in order to maintain compliance with FCC Rules and Regulations.

Laser Device
All Hewlett-Packard systems equipped with a laser device comply with safety standards, including International Electrotechnical Commission (IEC) 825. With specific regard to the laser, the equipment complies with laser product performance standards set by government agencies as a Class 1 laser product. The product does not emit hazardous light; the beam is totally enclosed during all modes of customer operation and maintenance.

Enterprise Virtual Array Hardware Configuration Guide

111

Regulatory Notices and Specifications

Laser Safety Warnings


Heed the following Warning:
WARNING: To reduce the risk of exposure to hazardous radiation: Do not try to open the laser device enclosure. There are no user-serviceable components inside. Do not operate controls, make adjustments, or perform procedures to the laser device other than those specified herein. Allow only HP authorized service technicians to repair the laser device.

Compliance with CDRH Regulations


The Center for Devices and Radiological Health (CDRH) of the U.S. Food and Drug Administration implemented regulations for laser products on August 2, 1976. These regulations apply to laser products manufactured from August 1, 1976. Compliance is mandatory for products marketed in the United States.

Certification and Classification Information


This product contains a laser internal to the Optical Link Module (OLM) for connection to the Fibre communications port. In the USA, the OLM is certified as a Class 1 laser product conforming to the requirements contained in the Department of Health and Human Services (DHHS) regulation 21 CFR, Subchapter J. The certification is indicated by a label on the plastic OLM housing. Outside the USA, the OLM is certified as a Class 1 laser product conforming to the requirements contained in IEC 825-1:1993 and EN 60825-1:1994, including Amendment 11:1996. The OLM includes the following certifications:

UL Recognized Component (USA) CSA Certified Component (Canada) TUV Certified Component (European Union) CB Certificate (Worldwide)

Canadian Notice (Avis Canadien)


Class A Equipment
This Class A digital apparatus meets all requirements of the Canadian Interference-Causing Equipment Regulations Cet appareil numrique de la classe A respecte toutes les exigences du Rglement sur le matriel brouilleur du Canada.

112

Enterprise Virtual Array Hardware Configuration Guide

Regulatory Notices and Specifications

Class B Equipment
This Class B digital apparatus meets all requirements of the Canadian Interference-Causing Equipment Regulations. Cet appareil numrique de la classe B respecte toutes les exigences du Rglement sur le matriel brouilleur du Canada.

European Union Notice


Products with the CE Marking comply with both the EMC Directive (89/336/EEC) and the Low Voltage Directive (73/23/EEC) issued by the Commission of the European Community. Compliance with these directives implies conformity to the following European Norms (the equivalent international standards are in parenthesis):

EN55022 (CISPR 22) - Electromagnetic Interference EN55024 (IEC61000-4-2, 3, 4, 5, 6, 8, 11) - Electromagnetic Immunity EN61000-3-2 (IEC61000-3-2) - Power Line Harmonics EN61000-3-3 (IEC61000-3-3) - Power Line Flicker EN60950 (IEC950) - Product Safety

Notice for France


DECLARATION D'INSTALLATION ET DE MISE EN EXPLOITATION d'un matriel de traitement de l'information (ATI), class A en fonction des niveaux de perturbations radiolectriques mis, dfinis dans la norme europenne EN 55022 concernant la Compatibilit Electromagntique.

Germany Noise Declaration


Schalldruckpegel Lp = 70 dB(A) Am Arbeitsplatz (operator position) Normaler Betrieb (normal operation) Nach ISO 7779:1999 (Typprfung)

Enterprise Virtual Array Hardware Configuration Guide

113

Regulatory Notices and Specifications

Japanese Notice

Harmonics Conformance (Japan)

Taiwanese Notice

114

Enterprise Virtual Array Hardware Configuration Guide

Regulatory Notices and Specifications

CountrySpecific Certifications
HP tests electronic products for compliance with country-specific regulatory requirements, as an individual item or as part of an assembly. The product label (see Figure 83) specifies the regulations with which the product complies.
Note: Elements without an individual product certification label are qualified as part of the next

higher assembly (for example, enclosure, rack, or tower).


.

CXO8157A

Figure 83: Typical enclosure certification label Note: The certification symbols on the label depend upon the certification level. For example, the FCC Class A certification symbol is not the same as the FCC Class B certification symbol.

Enterprise Virtual Array Hardware Configuration Guide

115

Regulatory Notices and Specifications

Fibre Channel Drive Enclosure Specifications


This appendix defines the physical, environmental, and power specifications of the Fibre Channel Drive Enclosure and the elements.

Physical Specifications
This section describes the physical specifications of the drive enclosure and elements.
WARNING: An assembled enclosure (all elements installed) weighs more than 29.5 kg (65 lb) and requires a minimum of two individuals to move.

Table 6 defines the dimensions and weights of the enclosure.


Table 6: Drive Enclosure Physical Specifications Shipping Empty Installed Carton Carton and Pallet

Note: Metric dimensions are expressed in whole numbers. For example, 10.795 cm is expressed as 108 mm. Millimeter dimensions are always expressed in whole numbers. Height Width Depth Weight 131 mm (5.16 in) 505 mm (19.875 in) 448 mm (17.625 in) 10.9 kg (24 lb) 131 mm (5.16 in) 505 mm (19.875 in) 448 mm (17.625 in) 30.9 kg (68 lb) 641 mm (25.25 in) 318 mm (12.5 in) 597 mm (23.5 in) 43.6 kg (96 lb) 768 mm (30.25 in) 610 mm (24 in) 1016 mm (40 in) 49 kg (108 lb)

Table 7 defines the dimensions of the elements (that is, EMU, blowers, I/O module, drives, and power supply).
Table 7: Drive Enclosure Elements Physical Specifications Specification Installed Shipping Carton

Note: Metric dimensions are expressed in whole numbers. For example, 10.795 cm is expressed as 108 mm. Millimeter dimensions are always expressed in whole numbers. Environmental Monitoring Unit (EMU) Height Width Depth Weight 114 mm (4.5 in) 241 mm (9.5 in) 35 mm (1.375 in) 0.6 kg (1.3 lb) 210 mm (8.25 in) 330 mm (13.5 in 108 mm (4.25 in) 0.91 kg (2.0 lb)

116

Enterprise Virtual Array Hardware Configuration Guide

Regulatory Notices and Specifications

Table 7: Drive Enclosure Elements Physical Specifications (Continued) Specification Installed Shipping Carton

Note: Metric dimensions are expressed in whole numbers. For example, 10.795 cm is expressed as 108 mm. Millimeter dimensions are always expressed in whole numbers. Blower Height Width Depth Weight I/O Module Height Width Depth Weight Disk Drive Height Width Depth Weight Height Width Depth Weight 114 mm (4.5 in) 26 mm (1.025 in) 241 mm (9.5 in) 0.59 kg (1.3 lb) 114 mm (4.5 in) 159 mm (6.25 in) 241 mm (9.5 in) 1.82 kg (4.0 lb) 216 mm (8.5 in) 114 mm (4.5 in) 330 mm (13.0 in) 1.0 kg (2.3 lb) 286 mm (11.25 in) 330 mm (13.0 in) 419 mm (16.5 in) 3.86 kg (8.5 lb) 114 mm (4.5 in) 41 mm (1.625 in) 241 mm (9.5 in) 0.59 kg (1.3 lb) 210 mm (8.25 in) 108 mm (4.25 in) 330 mm (13.0 in) 0.77 kg (1.7 lb) 140 mm (5.5 in) 159 mm (6.25 in) 83 mm (3.25 in) 0.45 kg (1.0 lb) 191 mm (7.5 in) 203 mm (8.0 in) 229 mm (9.0 in) 0.91 kg (2.0 lb)

Power Supply (without blower)

Environmental Specifications
To ensure optimum product operation you must maintain the operational environmental specifications listed in Table 8. The ambient temperature, that is the enclosure air intake or room temperature, is especially critical.
Table 8: Environmental Operating Specifications Ambient temperature: +10 C to +35 C (+50 F to +95 F) with an average rate of change of 1 C/hour maximum and a step change of 3 C or less. Maintaining the optimum ambient temperature within the specified range ensures that the internal operating temperatures support the drive manufacturers MTBF specifications. Relative humidity: 40% to 60% (noncondensing) with a step change of 10% or less (noncondensing) Air quality: Not to exceed a maximum of 500,000 particles, 0.5 micron or larger, per cubic foot of air. Heat dissipation: 1600 BTUs per hour

Enterprise Virtual Array Hardware Configuration Guide

117

Regulatory Notices and Specifications

When shipping, or placing this product in short term storage, HP recommends maintaining the environmental conditions listed in Table 9.
Table 9: Environmental Shipping or Short-Term Storage Specifications Ambient temperature: 40 C to +66 C (40 F to +151 F)

Relative humidity: 10% to 80% noncondensing


Altitude: 15,240 m (50,000 ft)

Power Specifications
The input voltage to the drive enclosure power supplies is a function of the country-specific input voltage to Enterprise storage system rack power distribution units (PDUs). Table 10 defines the AC input power available to the drive enclosure power supplies.
Caution: The AC power distribution within a rack ensures a balanced load to each PDU and reduces the possibility of an overload condition. Changing the cabling to or from a PDM could cause an overload condition. Table 10: Enterprise Storage System AC Input Line Voltages Specification AC Line Frequency AC Line VoltageJapan AC Line VoltageNorth America AC Line VoltageEurope AC Line Frequency AC Line VoltageJapan AC Line VoltageNorth America AC Line VoltageNorth America AC Line VoltageEurope Minimal 60 Hz Service 57 Hz 180 VAC 180 VAC 208 VAC 50 Hz Service 47 Hz 180 VAC 190 VAC 200 VAC 208 VAC 50 Hz 202 VAC 220 VAC 230 VAC 240 VAC 53 Hz 220 VAC 235 VAC 244 VAC 254 VAC 60 Hz 202 VAC 208 VAC 240 VAC 63 Hz 220 VAC 220 VAC 254 VAC Nominal Maximum

118

Enterprise Virtual Array Hardware Configuration Guide

Regulatory Notices and Specifications

Table 11 defines the AC input current and wattage to the drive enclosure power supplies.
Table 11: AC Input Current and Wattage Nominal Input Voltage 100 VACJBOD 208 VACNorth America 120 VACJBOD 220 VACNorth America 230 VACNorth America 240 VACEurope Amps 4.35 2.03 3.59 1.92 1.92 1.76 Watts 436 419 419 418 418 416 60-Hz Input 6.41 2.94 5.27 2.78 2.78 2.55 641 609 633 608 608 607 Maximum Amps Watts

50-Hz Input

Table 12 and Table 13 define the output voltage and current specifications of the drive enclosure power supply.
Table 12: Output Voltage and Current Specifications Range Specification Initial Voltage Steady state current Initial Voltage Steady state current Initial Voltage Steady state current Minimum +5.1 VDC +5.13 VDC 1.0 A +12.13 VDC 1.0 A +12.25 VDC 0.0 A +5.18 VDC N/A +12,25 VDC N/A +12.50 VDC N/A +5.23 VDC 26.0 A +12.37 VDC 26.0 A +12.75 VDC 2.0 A Nominal Maximum

+12.2 VDC (Disk Drive Voltage)

+12.5 VDC (Blower Voltage)

Table 13: Dual Power Supply Configuration Power Specifications Voltage +5.1 VDC (with a minimum +12.2 VDC load of 0A) +12.2 VDC (with a minimum +5 VDC load of 4A) +12.5 VDC Current (A) 26.0 A 28.0 A 2.0 A Total Maximum Peak Current (Simultaneous Seek Activity) +5.1 VDC +12.2 VDC +12.5 VDC 26.0 A 43.0 A 2.0 A Total 132.0 W 524.0 W 25.0 W 681.0 W Power (W) 132 W 342.0 W 25.0 W 499.0 W Maximum Continuous Current

Enterprise Virtual Array Hardware Configuration Guide

119

Regulatory Notices and Specifications

Fibre Channel Switch Specifications


The Fibre Channel Switch requires a clean, dry environment for normal operation. Table 14 lists the specifications for the Fibre Channel Switch.
Table 14: Fibre Channel Switch Specifications Weight Dimensions approximately 7.5 lbs. 8.50 x 1.57 x 16.00 inches (W x H x D) Note: The switch with extender is 21.66 in (depth). Operating Temperature Storage Temperature Power 0 C to 40 C for normal operation (ambient air temperature) -40 C to 80 C noncondensing 50 or 60 Hz 100250 VAC 0.50.3 A

120

Enterprise Virtual Array Hardware Configuration Guide

Regulatory Notices and Specifications

Controller Specifications
This section defines the physical, power, and environmental specifications of the controller enclosure.

Physical Specifications
Table 15 defines the dimensions of the controller and replaceable units.
Table 15: Controller Physical Specifications Specification Installed Shipping

Note: Metric dimensions are expressed in whole numbers. For example, 10.795 cm is expressed as 108 mm. Controller Enclosure Height Width Depth Weight Height Width Depth Weight Height Width Depth Weight 62 mm (2.45 in) 502 mm (19.75 in) 444 mm (17.49 in) 10.4 kg (23 lb) Cache Battery Assembly 57 mm (2.25 in) 184 mm (7.25 in) 83 mm (3.25 in) 1.3 kg (2.8 lb) Blower 55 mm (2.125 in) 116 mm (4.625 in) 105 mm (4.125 in) 0.4 kg (0.8 lb) 165 mm (6.5 in) 216 mm (8.5 in) 216 mm (8.5 in) 0.92 kg (2 lb) 108 mm (4.25 in) 324 mm (12.75 in) 162 mm (6.375 in) 1.5 kg (3.4 lb) 267 mm (10.5 in) 762 mm (30 in) 762 mm (30 in) 12.7 kg (28 lb)

Power Specifications
Table 16 and Table 18 define the controller power supply input power requirements and output power specifications.
Table 16: Controller Power Supply AC Power Requirements AC Input Voltage Minimum 180 VAC 208 VAC Nominal 202 VAC 208 VAC 240 VAC 254 VAC Maximum 220 VAC Minimum 47 Hz 57 Hz Frequency Nominal 50 Hz 60 Hz Maximum 53 Hz 63 Hz

Enterprise Virtual Array Hardware Configuration Guide

121

Regulatory Notices and Specifications

Table 17 defines the AC input current and wattage to the controller power supplies.
Table 17: AC Input Current and Wattage Nominal Input Voltage 100 VAC 120 VAC 208 VAC 220 VAC 240 VAC Amps 0.928 0.788 0.576 50-Hz Input 0.616 0.573 102 100 0.69 0.64 146 147 Watts 94 94 97 60-Hz Input 1.53 1.25 0.73 150 148 146 Maximum Amps Watts

Table 18 defines the output of the controller power supplies.


Table 18: Controller Power Supply Output Specifications Voltage Specification Output Voltage Steady state current Power Output Voltage Steady state current Power Minimum +3.3 VDC 3.23 VDC +5.1 VDC 4.80 VDC 5.00 VDC Total Current Total Power 1. +3.3 VDC steady state current requires a minimum 5.0-V load of 1 A. 2. Total power includes 14.0 watts for the internal blower. 5.25 VDC 5.0 A 25.5 W 24 A 105.6 W 3.30 VDC 3.36 VDC 18 A1 59.4W Nominal Maximum

Environmental Specifications
There are no controller environmental specifications. See the Environmental Specifications section in Enterprise Rack on page 124 for this information.

122

Enterprise Virtual Array Hardware Configuration Guide

Regulatory Notices and Specifications

Enterprise Rack
Physical Specifications
WARNING: The weight of the drive enclosure with the elements installed always requires at least two individuals to move. HP recommends using a fork lift or a hand truck to move an enclosure in the shipping container.
CXO7196A

Table 19 through Table 22 defines the dimensions and weights of the Enterprise storage system racks.
Table 19: Enterprise 42U Storage System Rack Physical Dimensions Height in / mm Enterprise 2C6D Enterprise 2C12D Enterprise 0C6D Enterprise 0C12D 78.75 / 2000.0 78.75 / 2000.0 78.75 / 2000.0 78.75 / 2000.0 Width in / mm 23.7 / 602 23.7 / 602 23.7 / 602 23.7 / 602 Depth in / mm 35.8 / 909 35.8 / 909 35.8 / 909 35.8 / 909 Max Wt lbs / kg 918 / 416 1350 / 612 818 / 371 1250 / 567

Table 20: Enterprise 42U Storage System Rack Shipping Dimensions Height in / mm Enterprise 2C6D Enterprise 2C12D Enterprise 0C6D Enterprise 0C12D 85.38 / 2169 85.38 / 2169 85.38 / 2169 85.38 / 2169 Width in / mm 36.0 / 914 36.0 / 914 36.0 / 914 36.0 / 914 Depth in / mm 48.0 / 1220 48.0 / 1220 48.0 / 1220 48.0 / 1220 Max Wt (with packaging) lbs / kg 1111 / 504 1543 / 700 1011 / 459 1443 / 654

Table 21: Enterprise 41U Storage System Rack Physical Dimensions Height in / mm Enterprise 2C6D Enterprise 2C12D Enterprise 0C6D Enterprise 0C12D 78.75 / 2000.0 78.75 / 2000.0 78.75 / 2000.0 78.75 / 2000.0 Width in / mm 23.7 / 602 23.7 / 602 23.7 / 602 23.7 / 602 Depth in / mm 39.1 / 993 39.1 / 993 39.1 / 993 39.1 / 993 Max Wt lbs / kg 917 / 416 1349 / 612 817 / 371 1249 / 567

Enterprise Virtual Array Hardware Configuration Guide

123

Regulatory Notices and Specifications

Table 22: Enterprise 41U Storage System Rack Shipping Dimensions Height in / mm Enterprise 2C6D Enterprise 2C12D Enterprise 0C6D Enterprise 0C12D 85.38 / 2169 85.38 / 2169 85.38 / 2169 85.38 / 2169 Width in / mm 36.0 / 914 36.0 / 914 36.0 / 914 36.0 / 914 Depth in / mm 48.0 / 1220 48.0 / 1220 48.0 / 1220 48.0 / 1220 Max Wt (with packaging) lbs / kg 1110 / 503 1542 / 699 1010 / 458 1442 / 654

Environmental Specifications
To ensure optimum product operation, you must maintain the operational environmental specifications listed in Table 23. The ambient temperature (the enclosure air intake or room temperature) is especially critical.
Table 23: Environmental Operating Specifications
.

Ambient temperature: +10 C to +35 C (+50 F to +95 F) with an average rate


of change of 1 C/hour maximum and a step change of 3 C or less. Maintaining the optimum ambient temperature within the specified range ensures that the internal operating temperatures support the drive manufacturers MTBF specifications. Relative humidity: 40% to 60% (noncondensing) with a step change of 10% or less (noncondensing). Air quality: Not to exceed a maximum of 500,000 particles, 0.5 micron or larger, per cubic foot of air. Heat dissipation: 12,708 BTUs per hour.

When shipping, or placing this product in short term storage, HP recommends maintaining the environmental conditions listed in Table 24.
Table 24: Environmental Shipping or Short Term Storage Specifications Ambient temperature: 40 C to +66 C (40 F to +151 F) Relative humidity: 10% to 80% (noncondensing) Altitude: 15,240 m (50,000 ft)

124

Enterprise Virtual Array Hardware Configuration Guide

Regulatory Notices and Specifications

Power Specifications
Table 25 defines the AC power specifications for the Enterprise storage system PDUs, PDMs, drive enclosure power supplies, and controller enclosure power supplies.
Table 25: Enterprise Storage System AC Power Specifications Nominal Input Voltage 60-Hz Service 202 VAC Voltage Range Power Receptacle 208 VAC Voltage Range Power Receptacle 240 VAC Voltage Range Power Receptacle 202 VAC Voltage Range Power Receptacle 220 VAC Voltage Range Power Receptacle 230 VAC Voltage Range Power Receptacle 240 VAC Voltage Range Power Receptacle Japan 180-220 VAC, 57-63Hz, 32 A, Single Phase 3-wire, 2-pole, IEC 309 North America 180-220 VAC, 57-63Hz, 30 A, Single Phase 3-wire, 2-pole, NEMA L6-30 Europe 208-254 VAC, 57-63 Hz, 32 A, Single Phase 3-wire, 2-pole, IEC 309 50-Hz Service Japan 180-220 VAC, 47-63Hz, 32 A, Single Phase 3-wire, 2-pole, IEC 309 North America 190-235 VAC, 47-63Hz, 30 A, Single Phase 3-wire, 2-pole, NEMA L6-30 North America 200-244 VAC, 47-63Hz, 30 A, Single Phase 3-wire, 2-pole, NEMA L6-30 Europe 208-254 VAC, 57-63 Hz, 32 A, Single Phase 3-wire, 2-pole, IEC 309 Specifications

The power consumption of an Enterprise storage system is 3,724 W.

Enterprise Virtual Array Hardware Configuration Guide

125

Regulatory Notices and Specifications

126

Enterprise Virtual Array Hardware Configuration Guide

glossary

This glossary defines terms used in this guide or related to this product and is not a comprehensive glossary of computer terms. 3U A unit of measurement representing three U spaces. U spacing is used to designate panel or enclosure heights. Three U spaces is equivalent to 5.25 inches (133 mm). See also rack-mounting unit. AL_PA Arbitrated Loop Physical Address. A 1-byte value the arbitrated loop topology uses to identify the loop ports. This value becomes the last byte of the address identifier for each public port on the loop. ambient temperature The air temperature in the area where a system is installed. Also, called intake temperature or room temperature. ANSI American National Standards Institute. A non-governmental organization that develops standards (such as SCSI I/O interface standards and Fibre Channel interface standards) used voluntarily by many manufacturers within the United States. arbitrated loop A Fibre Channel topology that links multiple ports (up to 126) together on a single shared simplex media. Transmissions can only occur between a single pair of nodes at any given time. Arbitration is the scheme that determines which node has control of the loop at any given moment. arbitrated loop physical address See AL_PA. arbitrated loop topology See arbitrated loop. array All the disk drives in a storage system that are known to and under the control of a controller pair. bail lock Part of the power supply AC receptacle that engages the AC power cord connector to ensure that the cord cannot be accidentally disconnected. baud The maximum rate of signal state changes per second on a communication circuit. If each signal state change corresponds to a code bit, then the baud rate and the bit rate are the same. It is also possible for signal state changes to correspond to more than one code bit so the baud rate may be lower than the code bit rate.
Enterprise Virtual Array Hardware Configuration Guide 127
Glossary

Glossary

Glossary

bay The physical location of an element, such as a drive, I/O module, EMU or power supply in a drive enclosure. Each bay is numbered to define its location. cabinet An alternate term used for a rack. cable assembly A fiber optic cable that has connectors installed on one or both ends. General use of these cable assemblies includes the interconnection of multimode fiber optic cable assemblies with either LC or SC type connectors.

When there is a connector on only one end of the cable, the cable assembly is referred to as a pigtail. When there is a connector on both ends of the cable, the cable assembly is referred to as a jumper.

client A software program that uses the services of another software program. The Command View EVA client is a standard internet browser. controller A hardware/firmware device that manages communications between host systems and other devices. Controllers typically differ by the type of interface to the host and provide functions beyond those the devices support. controller enclosure A unit that holds one or more controllers, power supplies, blowers, cache batteries, transceivers, and connectors. controller pair Two interconnected controller modules which together control a disk array. A controller pair and the disk array together constitute a storage system. CRU Customer Replaceable Unit. A storage system element that a user can replace without using special tools or techniques, or special training. customer replaceable unit See CRU. device ports Controller pair device ports connected to the storage systems disk drive array through the FC-AL. Also called a device-side port. device-side ports See device ports. disk drive blank A carrier that replaces a disk drive to control airflow within a drive enclosure whenever there is less than a full complement of storage devices. disk drive A carrier-mounted storage device supporting random access to fixed size blocks of data. disk drive A disk drive mounted in a drive enclosure that communicates with a controller pair through the device-side Fibre Channel loops. A disk drive is hardware with embedded software, as opposed to a virtual disk, which is constructed by the controllers. Only the controllers can communicate directly with the disks drives The disk drives, in aggregate, are called the array and constitute the storage pool from which the controllers create virtual disks.

128

Enterprise Virtual Array Hardware Configuration Guide

Glossary

drive blank See disk drive blank. drive enclosure A unit that holds storage system devices such as disk drives, power supplies, fans, I/O modules, transceivers or EMUs. dual power supply configuration See redundant power configuration. dual-loop A configuration where each drive is connected to a pair of controllers through two loops. These two Fibre Channel loops constitute a loop pair. EIA Electronic Industries Alliance. A standards organization specializing in the electrical and functional characteristics of interface equipment. electromagnetic interference See EMI. electrostatic discharge See ESD. element 1. In a drive enclosure, a device such as an EMU, power supply, disk, fan, or I/O module. The object can be controlled, interrogated, or described by the enclosure services process. 2. In the HP Open SAN Manager, a controllable object, such as the HP StorageWorks Enterprise Storage System. EMI Electromagnetic Interference. The impairment of a signal by an electromagnetic disturbance. EMU Environmental Monitoring Unit. An element which monitors the status of an enclosure, including the power, air temperature, and fan status. The EMU detects problems and displays and reports these conditions to a user and the controller. In some cases, the EMU implements corrective action. enclosure A unit used to hold various storage system devices such as disk drives, controllers, power supplies, fans, an EMU, or I/O modules. enclosure address bus An Enterprise Storage System bus that interconnects and identifies controller enclosures and drive enclosures by their physical location. Enclosures within a reporting group can exchange environmental data. This bus uses junction boxes and cables to assign enclosure numbers to each enclosure. Communications over this bus do not involve the FC-AL bus and are, therefore, classified as out-of-band communications. Enclosure Services Interface See ESI. Enclosure Services Processor See ESP.

Enterprise Virtual Array Hardware Configuration Guide

129

Glossary

Enterprise Virtual Array rack A unit that holds controller enclosures, drive enclosures, power distribution supplies, and enclosure address buses that comprise an Enterprise Storage System solution. Also, called the Enterprise Storage System rack. See also rack. Enterprise Virtual Array The Enterprise Virtual Array is a product that consists of one or more storage systems. Each storage system consists of a pair of controllers and the disk drives they manage. A storage system within the Enterprise Virtual Array can be formally referred to as an Enterprise Storage System, or generically referred to as the storage system. environmental monitoring unit See EMU. ESD Electrostatic Discharge. The emission of a potentially harmful static electric voltage as a result of improper grounding. ESI Enclosure Services Interface. The SCSI-3 engineering services interface implementation developed for HP StorageWorks products. A bus that connects the EMU to the drives. ESP Enclosure Services Processor. An EMU that implements an enclosures services process. fabric A Fibre Channel fabric switch or two or more interconnected Fibre Channel switches allowing data transmission. fabric port A port which is capable of supporting an attached arbitrated loop. This port on a loop will have the AL_PA hexadecimal address 00 (loop ID 7E), giving the fabric the highest priority access to the loop. A loop port is the gateway to the fabric for the node ports on a loop. fan The variable speed airflow device that cools an enclosure or element by forcing ambient air into an enclosure or element and forcing heated air out the other side. FC HBA Fibre Channel Host Bus Adapter. An interchangeable term for Fibre Channel adapter. See also FCA. FCA Fibre Channel Adapter. An adapter used to connect the host server to the fabric. Also, called a Host Bus Adapter (HBA) or a Fibre Channel Host Bus Adapter (FC HBA). See also FC HBA. FC-AL Fibre Channel Arbitrated Loop. The American National Standards Institutes (ANSI) document which specifies arbitrated loop topology operation. FCC Federal Communications Commission. The federal agency responsible for establishing standards and approving electronic devices within the United States. FCP Fibre Channel Protocol. The mapping of SCSI-3 operations to Fibre Channel.

130

Enterprise Virtual Array Hardware Configuration Guide

Glossary

fiber optic cable A transmission medium designed to transmit digital signals in the form of pulses of light. Fiber optic cable is noted for its properties of electrical isolation and resistance to electrostatic contamination. fiber optics The technology where light is transmitted through glass or plastic (optical) threads (fibers) for data communication or signaling purposes. fiber The optical media used to implement Fibre Channel. Fibre Channel adapter See FCA. Fibre Channel A data transfer architecture designed for mass storage devices and other peripheral devices that require very high bandwidth. Fibre The international spelling that refers to the Fibre Channel standards for optical media. field replaceable unit See FRU. frequency The number of cycles that occur in one second expressed in Hertz (Hz). Thus, 1 Hz is equivalent to one cycle per second. FRU Field Replaceable Unit. A hardware element that can be replaced in the field. This type of replacement can require special training, tools, or techniques. Therefore, FRU procedures are usually performed only by an authorized service representative. Gb Gigabit. A measurement of the rate at which the transfer of bits of data occurs. Sometimes referred to as Gbps. Nominally, a Gb is a transfer rate of 1,000,000,000 (109) bits per second. For Fibre Channel transceivers or FC loops the Gb transfer rates are:

1 Gb is a transmission rate of 1,062,500,000 bits per second. 2 Gb is a transmission rate of 2,125,000,000 bits per second.

GB Gigabyte. A unit of measurement defining either:

A data transfer rate. See also GBps. A storage or memory capacity of 1,073,741,824 (230) bytes.

GBIC Gigabit Interface Converter. See transceiver. Gbps Gigabit per second. A measurement of the rate at which the transfer of bits of data occurs. Nominally, a Gb is a transfer rate of 1,000,000,000 (109) bits per second. See also Gb.
Enterprise Virtual Array Hardware Configuration Guide 131

Glossary

GBps Gigabytes per second. A measurement of the rate at which the transfer of bytes of data occurs. A GBps is a transfer rate of 1,000,000,000 (109) bytes per second. See also GB. Giga (G) The notation to represent 109 or 1 billion (1,000,000,000). gigabaud An encoded bit transmission rate of one billion (109) bits per second. gigabit per second See Gbps. gigabit See Gb. graphical user interface See GUI. GUI Graphical User Interface. Software that displays the status of a storage system and allows its user to control the storage system. HBA Host Bus Adapter. See FCA. Host Bus Adapter See FCA. host computer See host. host ports A connection point to one or more hosts through a Fibre Channel fabric. A host is a computer that runs user applications and that uses (or can potentially use) one or more of the virtual disks that are created and presented by the controller pair. host A computer that runs user applications and uses (or can potentially use) one or more virtual disks created and presented by the controller pair. host-side ports See host ports. hot-pluggable A method of element replacement whereby the complete system remains operational during element removal or insertion. Replacement does not interrupt data transfers to other elements. HP OpenView Storage Management Appliance software A centralized, appliance-based monitoring and management interface that supports multiple applications, operating systems, hardware platforms, storage systems, tape libraries and SAN-related interconnect devices. It is included and resides on the HP OpenView Storage Management Appliance, a single aggregation point for data management.

132

Enterprise Virtual Array Hardware Configuration Guide

Glossary

HP StorageWorks Command View EVA The graphical user interface (GUI) through which a user can control and monitor a storage system. The Command View EVA software can be installed on more than one management appliance in a fabric. Each installation of the Command View EVA software is a management agent. The client for the agent is a standard browser. HP StorageWorks The HP trademarked name used to describe the set of rack-mounted enclosures containing controllers, transceivers, I/O modules, EMUs, disk drives, cables, blowers, and power supplies used to design and configure a solution-specific storage system. hub A communications infrastructure device to which nodes on a multi-point bus or loop are physically connected. It is used to improve the manageability of cables. I/O module Input/Output module. The enclosure element that is the FC-AL interface to the host or controller. I/O modules are bus speed specific; either 1 Gb or 2 Gb. in-band communication The method of communication between the EMU and controller that utilizes the FC-AL bus. See also out-of-band communication. input/output module See I/O module. intake temperature See ambient temperature. interface A set of protocols used between components such as cables, connectors, and signal levels. JBOD Just a Bunch of Disks. A number of disks connected to one or more controllers. just a bunch of disks See JBOD. KB Kilobyte. A unit of measurement defining either storage or memory capacity. 1. For storage, a KB is a capacity of 1,000 (103) bytes of data. 2. For memory, a KB is a capacity of 1,024 (210) bytes of data. K Kilo. A scientific notation denoting a multiplier of one thousand (1,000). laser A device that amplifies light waves and concentrates them in a narrow, very intense beam. LCD Liquid Crystal Display. The indicator on a panel that is associated with an element. The LCD is usually located on the front of an element. LED Light Emitting Diode. A semiconductor diode, used in an electronic display, that emits light when a voltage is applied to it.

Enterprise Virtual Array Hardware Configuration Guide

133

Glossary

light emitting diode See LED. link A connection between ports on Fibre Channel devices. The link is a full duplex connection to a fabric or a simplex connection between loop devices. loop ID Seven-bit values numbered contiguously from 0 to 126 decimal and represent the 127 valid AL_PA values on a loop (not all 256 hexadecimal values are allowed as AL_PA values per FCAL). loop pair A Fibre Channel attachment between a controller and disk drives. Disk drives connect to controllers through paired Fibre Channel arbitrated loops. There are two loop pairs, designated loop pair 1 and loop pair 2. Each loop pair consists of two loops (called loop A and loop B) that operate independently during normal operation, but provide mutual backup in case one loop fails. loop switch A unit that acts as a central point of interconnection and establishes a fault-tolerant physical loop topology. loop See arbitrated loop. management agent The Command View EVA software that controls and monitors the Enterprise storage system. The software can exist on more than one management appliance in a fabric. Each installation of the Command View EVA software is a management agent. MB Megabtye. A term defining either:

A data transfer rate. See also MBps. A measure of either storage or memory capacity of 1,048,576 (220) bytes.

Mb Megabit. A term defining a data transfer rate. See also Mbps. Mbps Megabits per second. A measure of bandwidth or data transfers occurring at a rate of 1,000,000 (106) bits per second. MBps Megabytes per second. A measure of bandwidth or data transfers occurring at a rate of 1,000,000 (106) bytes per second. Mega A notation denoting a multiplier of 1 million (1,000,000). Network Storage Controller See NSC. node port A device port that can operate on the arbitrated loop topology.

134

Enterprise Virtual Array Hardware Configuration Guide

Glossary

NSC Network Storage Controller. The controllers used by the Enterprise Storage System. OCP Operator Control Panel. The element that displays the controllers status using LEDs and an LCD. Information selection and data entry is controlled by the OCP pushbuttons. operator control panel See OCP. out-of-band communication Communication between an enclosure and reporting group elements that does not use the FC-AL bus, such as the enclosure address bus. See also in-band communication. parity A method of checking if binary numbers or characters are correct by counting the ONE bits. In odd parity, the total number of ONE bits must be odd; in even parity, the total number of ONE bits must be even. Parity information can be used to correct corrupted data. PDM Power Distribution Module. A thermal circuit breaker equipped power strip that distribute power from a PDU to Enterprise Storage System elements. PDU Power Distribution Unit. The rack device that distributes conditioned AC or DC power within a rack. port A Fibre Channel connector on a Fibre Channel device. power distribution module See PDM. power distribution unit See PDU. power supply An element that develops DC voltages for operating the storage system elements from either an AC or DC source. rack A floor-standing structure primarily designed for, and capable of, holding and supporting storage system equipment. All racks provide for the mounting of panels per Electronic Industries Alliance (EIA) Standard RS-310-C. rack-mounting unit A measurement for rack heights based upon a repeating hole pattern. It is expressed as U spacing or panel heights. Repeating hole patterns are spaced every 1.75 inches (44.45 mm) and based on EIAs Standard RS-310-C. For example, a 3U unit is 5.25-inches (133.35 mm) high and a 4U unit is 7.0-inches (177.79 mm) high. redundancy 1. Element RedundancyThe degree to which logical or physical elements are protected by having another element that can take over in case of failure. For example, each loop of a device-side loop pair normally work independently but can take over for the other in case of failure. 2. Data RedundancyThe level to which user data is protected. Redundancy is directly proportional to cost in terms of storage usage; the greater the level of data protection, the more storage space is required.

Enterprise Virtual Array Hardware Configuration Guide

135

Glossary

redundant power configuration A capability of the Enterprise Storage System racks and enclosures to allow continuous system operation by preventing single points of power failure.

For a rack, two AC power sources and two power conditioning units distribute primary and redundant AC power to enclosure power supplies. For a controller or drive enclosure, two power supplies ensure that the DC power is available even when there is a failure of one supply, one AC source, or one power conditioning unit. Implementing the redundant power configuration provides protection against the loss or corruption of data.

room temperature See ambient temperature. SCSI 1. Small Computer System Interface. An American National Standards Institute (ANSI) interface that defines the physical and electrical parameters of a parallel I/O bus used to connect computers and a maximum of 16 bus elements. 2. The communication protocol used between a controller pair and the hosts. Specifically, the protocol is FC-AL or SCSI on a Fibre Channel. SCSI is the higher command-level protocol and Fibre Channel is the low-level transmission protocol. The controllers have full support for SCSI-2; additionally, they support some elements of SCSI-3. SCSI-3 Enclosure Services See SES. SCSI-3 The ANSI standard that defines the operation and function of Fibre Channel systems. SES SCSI-3 Enclosures Services. Those services that establish the mechanical environment, electrical environment, and external indicators and controls for the proper operation and maintenance of devices within an enclosure. small computer system interface See SCSI. solutions rack A rack containing controller enclosures, drive enclosures, power distribution, enclosure address buses, and so forth that provide a specific solution such as the Enterprise storage system rack. See also rack. storage system The controllers, storage devices, enclosures, cables, and power supplies and their software. switch An electromechanical device that initiates an action or completes a circuit. TBps Terabytes per second. A data transfer rate of 1,000,000,000,000 (1012) bytes per second. TB Terabyte. A term defining either:

A data transfer rate. See also TBps. A measure of either storage or memory capacity of 1,099,5111,627,776 (240) bytes.

136

Enterprise Virtual Array Hardware Configuration Guide

Glossary

terminator Interconnected elements that form the ends of the transmission lines in the enclosure address bus. topology An interconnection scheme that allows multiple Fibre Channel ports to communicate. Point-to-point, arbitrated loop, and switched fabric are all Fibre Channel topologies. transceiver The device that converts electrical signals to optical signals at the point where the fiber cables connect to the FC elements such as hubs, controllers, or adapters. Also called a Gigabit Interface Converter (GBIC). units See rack-mounting units.

Enterprise Virtual Array Hardware Configuration Guide

137

Glossary

138

Enterprise Virtual Array Hardware Configuration Guide

index

0C12D configuration describing features 22 using 73 0C6D + 6D configuration describing features 99 enclosure address bus 99 Fibre Channel loops 99 0C6D configuration describing features 21 expanding 99 2 x 2C12D + 0C12D configuration describing features 73 enclosure address bus 73 Fibre Channel loops 74 2C12D + 0C6D configuration describing features 63 enclosure address bus 63 Fibre Channel loops 64 2C12D configuration cable management 40 describing features 18 enclosure address bus 30 expanding 63, 73 Fibre Channel loops 31 2C6D + 6D configuration describing features 89 enclosure address bus 89 Fibre Channel loops 90 2C6D configuration cable management 50 describing features 17, 41, 88 enclosure address bus 41 expanding 89 Fibre Channel loops 42 41U rack 16 42U rack 16 8C8D configuration cable management 56 describing features 19, 51

enclosure address bus 51 Fibre Channel loops 52

A
AC power specifications 122 AC power specifications 119 addition, FC loop switch 85 addressing enclosures 63 air quality environmental specifications 117 operating specifications 124 altitude shipping 118, 124 short term storage 118 ambient temperature environmental specifications 117 operating 124 shipping 118, 124 short term storage 118, 124 array expansion 73 ASCII configuration 51 audience 10 authorized reseller, HP 14

B
blowers, physical specifications 117 BTU specifications 117, 124

C
cable containment spools 39, 40 cable management 39, 50, 56 cable management arms 39 cable reconfiguration 85 cables FCC compliance statement 111 CDRH, compliance regulations 112 Center for Devices and Radiological Health. See CDRH
139

Enterprise Virtual Array Hardware Configuration Guide

Index

certification product labels 115 Class A equipment, Canadian compliance statement 112 Class B equipment, Canadian compliance statement 113 Command View EVA 25 configurations, expansion 73 controllers describing features 25 physical dimensions 121 power requirements 121 conventions document 11 equipment symbols 12 text symbols 11 country-specific certifications 115

D
DC power specifications 119, 122 disk drives, MTBF specifications 117, 124 document conventions 11 prerequisites 10 related documentation 10 drive enclosures, adding 88 dual power supplies, controller 25 dual-rack configuration 63

short term storage 124 equipment symbols 12 expansion connecting Fibre Channel cables 74 expandable configurations 18, 19 expansion rack 21, 22 expansion configurations 21 expansion panels removing 85 using 31 expansion panels, usage of 0C6D + 6D configuration 104 2 x 2C12D + 0C12D configuration 79 2C12D + 0C6D configuration 69 2C12D configuration 36 2C6D + 6D configuration 95 2C6D configuration 46 expansion racks 22, 63, 73, 74

F
FC drive enclosures adding 88 describing features 24 FC loop switches adding 85 describing features 26 environmental specifications 120 using 31 FCC Class A Equipment, compliance notice 110 Class B Equipment, compliance notice 111 Declaration of Conformity 111 modifications 111 notice 110 FCC Class A certification 110 Federal Communications Commission (FCC) notice 110 Federal Communications Commission. See FCC Fibre Channel cable management 39, 50, 56 Fibre Channel cables connecting 31 reconfiguring 85 Fibre Channel drive enclosure 24 Fibre Channel loop configurations 31 flumes 39, 40 fork lift, using 123

E
enclosure address bus configurations 2 x 2C12D + 0C12D configuration 73 2C12D + 0C6D configuration 63 2C12D configuration 30 2C6D configuration 41 8C8D configuration 51 enclosure address bus terminator 30, 89 enclosure address bus, expanding 63, 73 enclosure address bus, polarity 63, 73 enclosure certification label 115 enclosures, physical specifications 116 environmental specifications air quality 117, 124 altitude 118 ambient temperature operating specifications 124 shipping 124 short term storage 124 controllers 122 drive enclosure 117 Fibre Channel loop switches 120 heat dissipation 124 relative humidity 117, 118, 124 shipping 118, 124

G
getting help 14 graphite rack 16

H
hand truck, using 123

140

Enterprise Virtual Array Hardware Configuration Guide

Index

help, obtaining 14 HP authorized reseller 14 storage website 14 technical support 14

loop switches, environmental specifications for 120 loop topology 26

M
master racks 63, 74 moving enclosure WARNING 123 MTBF 117, 124

I
increasing storage capacity 22, 23 intake temperature See ambient temperature

O
opal rack 16

J
junction boxes 30

P
physical specifications blowers 117 enclosures 116 power specifications AC 119, 122 controller 121 DC 119, 122 drive enclosure 118 prerequisites 10 product certification 115 79

L
labels enclosure certification 115 product certification 115 laser device regulatory compliance notice 111 lasers radiation, warning 112 loop 1A 0C6D + 6D configuration 100, 104 2 x 2C12D + 0C12D configuration 75, 2C12D + 0C6D configuration 65, 69 2C12D configuration 32, 36 2C6D + 6D configuration 90, 95 2C6D configuration 42, 46 8C8D configuration 52 loop 1B 0C6D + 6D configuration 101, 105 2 x 2C12D + 0C12D configuration 76, 2C12D + 0C6D configuration 66, 70 2C12D configuration 33, 37 2C6D + 6D configuration 92, 96 2C6D configuration 43, 47 8C8D configuration 53 loop 2A 0C6D + 6D configuration 102, 106 2 x 2C12D + 0C12D configuration 77, 2C12D + 0C6D configuration 67, 71 2C12D configuration 34, 38 2C6D + 6D configuration 93, 97 2C6D configuration 44 8C8D configuration 54 loop 2B 0C6D + 6D configuration 103, 107 2 x 2C12D + 0C12D configuration 78, 2C12D + 0C6D configuration 68, 72 2C12D configuration 35, 39 2C6D + 6D configuration 94, 98 2C6D configuration 45, 49 8C8D configuration 55

R
rack environmental specifications 124 power specifications 125 rack additions, drive enclosures 88 rack expansion 18, 19, 21 rack stability, warning 13 rack upgrades, FC loop switches 85 radial clips 39 reconfiguration, cables 85 regulatory compliance notices cables 111 Class A 110 Class B 111 European Union 113 Japan 114 laser devices 111 modifications 111 Taiwan 114 regulatory notices 110 related documentation 10 relative humidity drive enclosure 117, 118 operating 124 shipping 118, 124 short term storage 118, 124 room temperature See ambient temperature

80

81

82

S
SFP 26
141

Enterprise Virtual Array Hardware Configuration Guide

Index

shipping container, moving 123 shipping specifications 118, 124 short term storage specifications 124 specifications disk drive, MTBF 117, 124 enclosure 121 environmental 124 heat dissipation 117 operating 124 physical 116, 121 power 118, 121 shipping 124 short term storage 124 spools 40 storage racks 16 switches 31 symbols in text 11 symbols on equipment 12 system expansion 21, 22, 73

triple-rack configuration 73 two-rack configuration 63

U
upgrading version 83 using fork lifts 123 using hand trucks 123

V
version comparison 83 version upgrade 83

W
warning rack stability 13 symbols on equipment 12 warnings lasers, radiation 112 WARNINGs, enclosure moving 123 websites HP storage 14 wire looms 39

T
technical support, HP 14 terminator 30, 41, 89 text symbols 11 topology 26 transceivers 26

Y
Y cables 30, 41

142

Enterprise Virtual Array Hardware Configuration Guide