A
5.13
5.13
7.25
7.25
7.25
8.00
8.00
8.00
10.50
10.50
10.50
11.00*
11.00*
11.00*
14.00**
14.00**
14.00**
S-12K84
February 2006
B
5.00
7.00
6.75
7.63
10.00
7.25
10.00
11.75
8.38
11.00
14.00
10.00
13.00
20.00
11.75
16.75
23.75
Drive Shaft
Location
D
D1
D2
9.75 3.75 6.25 3.75
11.75 3.75 6.25 3.75
11.25 5.00 8.50 5.00
12.13 5.00 8.50 5.00
14.63 5.00 8.50 5.00
13.00 6.25 10.25 6.25
15.50 6.25 10.25 6.25
17.63 6.25 10.25 6.25
15.38 6.25 11.25 6.75
18.00 6.25 11.25 6.75
21.18 6.25 11.25 6.75
18.38 8.75 14.75 8.75
21.38 8.75 14.75 8.75
28.38 8.75 14.75 8.75
19.94 11.00 18.00 11.00
25.19 11.00 18.00 11.00
32.19 11.00 18.00 11.00
Keyway
9.63
9.63
12.81
12.81
12.81
15.06
15.06
15.06
17.38
17.38
17.38
21.63
21.63
21.63
26.13
26.13
26.13
6.88
6.88
8.88
8.88
8.88
10.63
10.63
10.50
11.88
12.25
12.25
15.13
15.13
16.25
20.69
19.50
19.50
6.25
6.25
7.75
7.75
7.75
8.75
8.75
8.50
10.25
11.00
11.00
12.75
12.75
15.00
19.38
17.00
17.00
9.25
9.25
12.13
12.13
12.13
13.63
13.63
13.63
17.25
17.25
17.25
19.75
19.75
19.75
23.25
23.25
23.25
5.00
5.00
6.75
6.75
6.75
8.25
8.25
8.25
8.75
8.75
8.75
11.75
11.75
11.75
14.50
14.50
14.50
.625
.625
.750
.750
.750
.875
.875
.875
1.125
1.125
1.125
1.375
1.375
1.375
1.562
1.562
1.562
.188 x .094
.188 x .094
.188 x .094
.188 x .094
.188 x .094
.188 x .094
.188 x .094
.188 x .094
.250 x .125
.250 x .125
.250 x .125
.312 x .156
.312 x .156
.312 x .156
.375 x .188
.375 x .188
.375 x .188
Inlet &
Disch. Dia
1.0 NPT
2.0 NPT
1.25 NPT
2.0 NPT
2.5 NPT
1.5 NPT
2.5 NPT
3.0 NPT
2.5 NPT
4.0 NPT
4.0 NPT
3.0 NPT
5.0 NPT
6.0 FLG
4.0 NPT
6.0 FLG
8.0 FLG
Approx.
AX Net Wt.
(lbs.)
1.25
32
1.25
43
1.75
69
1.75
74
1.75
102
2.00
88
2.00
109
2.00
128
2.50
143
2.50
170
2.50
204
3.00
245
3.00
285
3.00
425
3.50
400
3.50
530
3.50
650
OPERATING PRINCIPLE
Two figure-eight lobe impellers mounted on parallel shafts rotate in opposite directions. As
each impeller passes the blower inlet, it traps a definite volume of air and carries it around
the case to the blower outlet, where the air is discharged. With constant speed operation,
the displaced volume is essentially the same regardless of pressure, temperature or barometric pressure.
Timing gears control the relative position of the impellers to each other and maintain
small but definite clearances. This allows operation without lubrication being required inside
the gas casing.
S-12K84
February 2006
Dresser Roots
Headquarters
16240 Port Northwest Drive
Houston, TX 77041
Toll Free (US): 1-877-363-7668
Ph: 832-590-2305
Toll Free (US) Fax: 1-877-357-7238
Fx: 832-590-2326
Dresser Roots
Connersville Operation
900 West Mount Street
Connersville, IN 47331
Ph: 765-827-9200
Fx: 765-827-9266
Dresser Roots
Holmes Operation
PO Box B7
Off St. Andrews Rd
Turnbridge, Huddersfield
England HD1 6RB
Ph: +44 (0) 1484 422 222
Fx: +44 (0) 1484 422 668
2006 Dresser, Inc. all rights reserved. Printed in the U.S.A. All information subject to change without notice. ROOTS-FLO and Universal RAI are registered trademarks of Dresser,
Inc. EasyAir, TRI-NADO, The Original ROOTS Blower, Universal RAI-J, Universal RAI-G, RAM, WHISPAIR, XLP Prime and XLP are trademarks of Dresser, Inc.
10 0.2
49 0.6
76 0.8
24 0.3
102 0.8
156 1.2
40 0.4
113 1.0
149 1.3
55 0.5
156 1.2
205 1.6
95 0.7
262 2.0
344 2.9
38 0.4
92 0.8
204 1.7
79 0.6
188 1.3
410 3.4
105 0.8
249 1.6
542 4.5
72 0.6
211 1.7
355 3.3
123 0.9
358 2.6
598 5.2
187 1.2
529 3.9
881 7.8
140 1.0
400 3.4
546 5.2
224 1.5
643 4.9
876 7.3
420 2.6
1205 8.1
1641 11.9
195 1.3
526 4.0
788 6.9
362 2.2
970 6.5
1450 10.9
600 3.3
1590 9.7
2370 15.7
7
46
73
19
97
150
34
108
144
48
149
199
85
253
334
32
87
198
68
177
400
92
236
529
63
203
346
110
345
585
170
513
865
126
387
523
203
621
855
380
1164
1601
179
511
772
336
944
1424
563
1553
2333
0.3
0.8
1.2
0.4
1.3
1.9
0.6
1.6
2.0
0.8
2.0
2.5
1.2
3.3
4.5
0.6
1.3
2.6
1.1
2.2
5.3
1.4
2.8
7.0
1.0
2.7
5.0
1.6
4.6
8.0
2.2
6.4
11.8
1.8
5.3
7.7
2.7
7.9
11.4
4.8
13.9
19.3
2.3
6.4
10.5
4.0
11.0
17.5
6.3
17.0
26.9
4
43
70
15
93
146
30
104
140
43
144
193
78
245
327
28
82
194
60
169
392
82
225
519
56
196
340
100
335
575
158
500
852
116
377
522
187
605
838
351
1133
1570
168
500
761
316
925
1404
534
1524
2304
0.3
1.1
1.6
0.6
1.8
2.7
0.9
2.1
2.7
1.1
2.7
3.5
1.7
4.5
6.1
0.9
1.8
3.6
1.5
3.1
7.2
2.0
4.0
9.5
1.4
3.7
6.6
2.2
6.0
10.7
3.2
8.9
15.8
2.6
7.2
10.3
3.9
10.9
15.4
7.1
19.5
27.0
3.3
9.0
14.2
5.9
15.5
24.1
9.3
24.3
37.2
2
41
68
11
89
143
27
101
137
39
140
189
72
239
321
24
78
190
53
162
385
73
217
510
51
191
334
92
326
567
147
490
842
107
368
513
172
591
824
323
1107
1544
158
490
751
299
908
1387
510
1500
2280
0.4
1.3
1.9
0.8
2.3
3.4
1.1
2.7
3.4
1.4
3.5
4.5
2.3
5.8
7.7
1.1
2.2
4.5
2.0
4.1
9.1
2.6
5.3
12.0
1.8
4.7
8.2
2.9
7.7
13.5
4.2
11.4
19.9
3.3
9.1
12.8
5.1
14.0
19.5
9.3
25.2
34.6
4.3
11.5
17.8
7.7
20.0
30.7
12.3
31.6
47.9
39
66
8
86
140
24
98
134
35
136
185
66
234
315
21
75
186
48
156
379
66
209
503
46
186
329
85
319
560
138
480
832
100
360
506
160
579
812
301
1084
1521
150
481
742
284
893
1373
489
1479
2259
1.6
2.3
0.9
2.8
4.2
1.3
3.2
4.1
1.7
4.2
5.4
2.8
7.0
9.3
1.3
2.7
5.5
2.4
5.0
11.0
3.2
6.5
14.3
2.2
5.7
9.9
3.6
9.4
16.2
5.1
13.8
23.9
4.1
11.0
15.3
6.3
17.0
23.5
11.6
30.8
43.2
5.4
13.9
21.4
9.6
24.5
37.3
15.4
39.0
58.6
1.8
2.7
3.3
4.9
1.6
3.8
4.8
2.1
5.0
6.4
3.3
8.3
10.9
1.5
3.1
6.4
2.9
5.9
12.9
3.8
7.7
17.0
2.6
6.7
11.5
4.3
11.1
19.0
6.1
16.3
27.9
4.8
12.8
17.8
7.5
20.0
27.6
13.8
36.5
49.8
6.4
16.4
25.0
11.4
29.0
43.9
18.4
46.3
69.4
38
64
83
137
21
95
131
31
132
181
61
229
310
18
72
183
42
151
374
59
203
496
42
181
325
78
312
553
130
472
824
93
353
499
149
567
801
279
1063
1500
142
473
734
271
880
1359
470
1460
2240
3.8
5.6
1.8
4.3
5.5
2.4
5.7
7.4
3.8
9.5
12.5
1.8
3.6
7.4
3.4
6.9
14.8
4.4
8.9
19.5
3.0
7.7
13.2
4.9
12.8
21.7
18.8
31.9
5.5
14.7
20.3
8.7
23.1
31.6
16.2
42.2
57.4
7.4
18.8
28.6
13.3
33.5
50.5
464
816
86
347
492
139
557
790
260
1044
1481
134
466
727
258
867
1347
2.1
3.1
81
135
19
93
129
28
129
178
57
224
306
15
69
181
37
146
369
53
196
490
38
177
321
72
306
547
36
63
1 PSI
2 PS I
3 PS I
4 PS I
5 PS I
6 PS I
7 PS I
CFM BHP CFM BHP CFM BHP CFM BHP CFM BHP CFM BHP CFM BHP
29
56
10.4
26.3 441 28.7 436 31.2 421 33.7 415 36.1
39.5 703 43.1 697 46.7 684 50.4 679 54.0
18.8
47.1
70.3
530
763
115
447
708
226
835
1315
7.8
20.4 325 22.3 320 24.2 316 26.1 311 27.9
27.4 470 30.4 466 32.9 461 35.5 457 38.0
421 38.6
682 57.6
307 29.8
452 40.5
290
531
70
330
475
167
310
9.6
20.5
133
356
77 8.7
113 11.2
7.6 79 8.2
9.8 115 10.5
62
173
7.1 81
9.1 117
3.3
4.9
6.5 82
8.4 118
3.1
4.5
120
170
31
57
6.0 84
7.7 120
2.8
4.2
86
122
32
59
4
14
15
6
14
15
10
15
16
10
14
15
10
12
15
8
14
15
8
12
15
8
12
15
10
14
16
10
14
16
8
12
15
12
16
16
10
15
16
8
12
14
12
16
16
12
15
16
10
12
12
6
28
53
12
69
119
18
78
110
27
113
159
55
213
278
19
56
160
46
134
332
63
181
452
36
158
391
70
276
501
135
445
770
71
300
445
135
495
715
292
997
1389
117
413
674
228
793
1256
446
1398
2178
0.3
2.0
3.1
0.6
3.8
5.8
1.3
4.5
5.9
1.7
5.6
7.6
2.7
7.9
12.7
1.1
3.5
8.0
1.9
5.8
15.9
2.5
7.5
19.8
2.2
7.5
14.0
3.5
12.3
23.2
4.1
15.6
32.1
4.7
15.8
21.6
6.2
23.5
34.0
9.1
35.0
54.9
6.2
20.4
30.6
11.2
34.4
54.6
15.0
44.7
6.4
10 PS I
11 PS I
12 PS I
13 PS I
14 PS I
15 PS I
MA X. VA C UUM
CFM BHP CFM BHP CFM BHP CFM BHP CFM BHP CFM BHP *Hg CFM BHP
1. Performance based on inlet air at standard pressure of 14.7 psia, standard temperature of 68 F, and specific gravity of 1.0.
2. Vacuum ratings based on inlet air at standard temperature of 68F, discharge pressure of 30 Hg and specific gravity of 1.0.
Frame Speed
Size RPM
1160
22
3600
5275
1160
24
3600
5275
1160
32
2800
3600
1160
33
2800
3600
1160
36
2800
3600
860
42
1760
3600
860
45
1760
3600
860
47
1760
3600
700
53
1760
2850
700
56
1760
2850
700
59
1760
2850
700
65
1760
2350
700
68
1760
2350
700
615 1760
2350
575
76
1400
2050
575
711 1400
2050
575
718 1400
2050
PERFORMANCE TABLE