Property Inspection Report

Orchard Road, Minnetonka, mn Inspection prepared for: Abbey Bryduck Real Estate Agent: Joel Songstad - Edina Realty Date of Inspection: 10/10/2013 Time: 10:00am Inspector: Nick Bryduck Associate member of ASHI - I.T.A. Certified Home Inspector 121 16TH Ave North, Hopkins, MN 55343 Phone: 952-292-7035 Email: nick@metroinspectionsmn.com metroinspectionsmn.com

Metro Inspections

Orchard Road, Minnetonka, mn

Report Summary Report Summary The summary below consists of potentially significant findings. These findings can be a safety hazard, a deficiency requiring a major expenses to correct or items I would like to draw extra attention to. The summary is not a complete listing of all the findings in the report, and reflects the opinion of the inspector. Please review all of the pages of the report as the summary alone does not explain all the issues. All repairs must be done by a licensed &bonded trade or profession. I recommend obtaining a copy of all receipts, warranties and permits for the work done. Interior Areas Page 6 Item: 4 Electrical 2-prong outlets The home contained outdated, ungrounded 2-prong electrical outlets. Although this condition may have been commonly considered safe or acceptable at the time the home was originally constructed, as general knowledge of safe building practices has improved with the passage of time, building standards have changed to reflect current understanding. Consider updating the existing condition to meet generallyaccepted current standards. Page 8 Item: 10 Window Condition hardware difficult to operate at one or more locations. Recommend review and repair as needed by qualified window contractors Broken/cracked glass pane noted, repairs needed. Bedrooms Page 9 Item: 4 Electrical 2-prong outlets The home contained outdated, ungrounded 2-prong electrical outlets. Although this condition may have been commonly considered safe or acceptable at the time the home was originally constructed, as general knowledge of safe building practices has improved with the passage of time, building standards have changed to reflect current understanding. Consider updating the existing condition to meet generallyaccepted current standards. Page 10 Item: 6 Smoke Detectors There were no smoke detectors present in the bedroom(s). Bathroom Page 11 Item: 7 Plumbing Pressure weakens when water is running in other areas. Hot water temp is just over 130 degrees- recommend turning down water heater to achieve 120 or below temp to prevent injury. Page 13 Item: 12 Sinks Nonstandard flex drain used under sink. Should be replaced with correct part by licensed plumber. Poor pressure flow when running several fixtures in one area. Kitchen Page 14 Item: 7 Oven & Range Oven is Electric- Did not operate. Door was being held up with rope. Recommend repair, or replacement. Page 15 Item: 8 Sinks Drain line leaks under sink. Page 15 Item: 9 Vent Condition Hood vents in to soffit. Recommend having a professional contractor install a roof vent.

Page 1 of 44

Metro Inspections

Orchard Road, Minnetonka, mn

Page 15 Item: 10 Window Condition Hardware difficult to operate at one or more locations. Recommend review and repair as needed by qualified window contractors. Laundry Page 17 Item: 2 Dryer Vent Irregular materials were used to create a dryer vent. Recommend replacing the vent pipe with the proper materials. Page 17 Item: 4 GFCI The laundry receptacle should be GFCI protected type. Page 17 Item: 6 Wash Basin Nonstandard flex drain used under sink. Should be replaced with correct part by licensed plumber. Page 18 Item: 8 Plumbing Hot and cold water supply to the wash basin were not properly supported. Recommend having a professional contractor remedy the situation. Heat/AC Page 21 Item: 10 Filters Disposable type filter appeared dirty. Replace as needed. Water Heater Page 23 Item: 5 Water Heater Apparent back draft potential carbon monoxide poisoning Condition hazard. Have plumber verify proper operation. corrosion and stains present from condensation or precipitation. Garage Page 24 Item: 4 Floor Condition Large cracks across the garage floor, recommend sealing cracks/voids. Foundation is cracking and showing signs of failure. Recommend review by a qualified professional contractor before purchase of the property. Electrical Page 28 Item: 1 Electrical Panel Knockouts need snap-in caps inside panel box. Should be installed to keep mice out of panel box and to avoid potential electrocution hazard. Questionable wiring in panel box. Have licensed electrician evaluate. Spliced & taped wires. Page 29 Item: 5 Fuses Recommend updating the service panel to circuit breakers. Roof Page 31 Item: 5 Gutter Recommend directing water away from under the porch to stop erosion next to foundation. Attic Page 33 Item: 7 Insulation There is some air bypass happing around the chimney. This Condition can create moisture in the attic leading to unwanted damage to the structure. Exterior Areas Page 35 Item: 1 Doors Screens on porch door, and window are damaged and need to be replaced. Foundation Page 38 Item: 1 Foundation Walls Mold-like bio growth observed. Professional testing & evaluation advised. Efflorescence observed; this is a mineral deposit left behind from exterior water infiltration. Page 2 of 44

Metro Inspections Page 39 Item: 4 Foundation Plumbing

Orchard Road, Minnetonka, mn Plumbing vent pipe has a broken connection in the laundry room. This is a hazard because sewer gas can come directly into the house. This should be repaired by a qualified professional contractor.

Grounds Page 40 Item: 1 Page 41 Item: 2

Driveway and Extensive cracks in sidewalk. Repair and / or monitor for Walkway Condition expansion and development of trip hazards. Grading Low areas were observed. Backfill is recommended.

Page 3 of 44

Metro Inspections

Orchard Road, Minnetonka, mn

We appreciate the opportunity to conduct this inspection for you! Please carefully read your entire Inspection Report. Call us after you have reviewed your report, so we can go over any questions you may have. Remember, when the inspection is completed and the report is delivered, we are still available to you for any questions you may have, throughout the entire closing process. Properties being inspected do not "Pass" or "Fail. - The following report is based on an inspection of the visible portion of the structure; inspection may be limited by vegetation and possessions. Depending upon the age of the property, some items like GFI outlets may not be installed; this report will focus on safety and function, not current code. This report identifies specific noncode, non-cosmetic concerns that the inspector feels may need further investigation or repair. For your safety and liability purposes, we recommend that licensed contractors evaluate and repair any critical concerns and defects. Note that this report is a snapshot in time. We recommend that you or your representative carry out a final walk-through inspection immediately before closing to check the condition of the property, using this report as a guide.

Page 4 of 44

Metro Inspections

Orchard Road, Minnetonka, mn

Inspection Details
1. Attendance In Attendance: Client present, Buyer Agent present 2. Home Type Home Type: Detached Single Family Home 3. Occupancy Occupancy: Occupied - Furnished The utilities were on at the time of inspection. ACCESS TO SOME ITEMS SUCH AS: ELECTRICAL OUTLETS, WINDOWS, WALL/FLOOR SURFACES, AND CABINET INTERIORS WAS RESTRICTED BY FURNITURE AND LARGE QUANTITY OF PERSONAL BELONGINGS. ANY SUCH ITEMS ARE EXCLUDED FROM THIS INSPECTION REPORT.

Page 5 of 44

Metro Inspections

Orchard Road, Minnetonka, mn

Interior Areas The Interior section covers areas of the house that are not considered part of the Bathrooms, Bedrooms, Kitchen or areas covered elsewhere in the report. Interior areas usually consist of hallways, foyer, and other open areas. Within these areas the inspector is performing a visual inspection and will report visible damage, wear and tear, and moisture problems if seen. Personal items in the structure may prevent the inspector from viewing all areas on the interior. The inspector does not usually test for mold or other hazardous materials. A qualified expert should be consulted if you would like further testing. 1. Cabinets
Good Fair Poor N/A None

X 2. Closets
Good Fair Poor N/A None

X 3. Doors
Good Fair Poor N/A None

X 4. Electrical
Good Fair Poor N/A None

Observations: 2-prong outlets The home contained outdated, ungrounded 2-prong electrical outlets. Although this condition may have been commonly considered safe or acceptable at the time the home was originally constructed, as general knowledge of safe building practices has improved with the passage of time, building standards have changed to reflect current understanding. Consider updating the existing condition to meet generally-accepted current standards.

Page 6 of 44

Metro Inspections

Orchard Road, Minnetonka, mn

5. Smoke Detectors
Good Fair Poor N/A None

Observations: Operated when tested.

Page 7 of 44

Metro Inspections

Orchard Road, Minnetonka, mn

6. Stairs & Handrail


Good Fair Poor N/A None

X 7. Patio Doors
Good Fair Poor N/A None

X 8. Screen Doors
Good Fair Poor N/A None

Observations: X Not installed, recommend installation and confirmation of proper screen door operation. Materials: Drywall walls noted.

9. Wall Condition
Good Fair Poor N/A None

X 10. Window Condition


Good Fair Poor N/A None

Materials: Wood framed double hung window noted. Observations: hardware difficult to operate at one or more locations. Recommend review and repair as needed by qualified window contractors Broken/cracked glass pane noted, repairs needed.

Page 8 of 44

Metro Inspections

Orchard Road, Minnetonka, mn

Bedrooms The main area of inspection in the bedrooms is the structural system. This means that all walls, ceilings and floors will be inspected. Doors and windows will also be investigated for damage and normal operation. Personal items in the bedroom may prevent all areas to be inspected as the inspector will not move personal items. 1. Locations Locations: Upstairs North West Upstairs South West Downstairs North East 2. Closets
Good Fair Poor N/A None

X 3. Doors
Good Fair Poor N/A None

X 4. Electrical
Good Fair Poor N/A None

Observations: 2-prong outlets The home contained outdated, ungrounded 2-prong electrical outlets. Although this condition may have been commonly considered safe or acceptable at the time the home was originally constructed, as general knowledge of safe building practices has improved with the passage of time, building standards have changed to reflect current understanding. Consider updating the existing condition to meet generally-accepted current standards.

5. Floor Condition
Good Fair Poor N/A None

Flooring Types: Carpet is noted. Hardwood flooring is noted.

6. Smoke Detectors
Good Fair Poor N/A None

Observations: There were no smoke detectors present in the bedroom(s). Page 9 of 44

Metro Inspections

Orchard Road, Minnetonka, mn

7. Wall Condition
Good Fair Poor N/A None

X 8. Window Condition
Good Fair Poor N/A None

Materials: Drywall walls noted.

Materials: Wood framed casement window noted.

Page 10 of 44

Metro Inspections

Orchard Road, Minnetonka, mn

Bathroom Bathrooms can consist of many features from jacuzzi tubs and showers to toilets and bidets. Because of all the plumbing involved it is an important area of the house to look over. Moisture in the air and leaks can cause mildew, wallpaper and paint to peel, and other problems. The home inspector will identify as many issues as possible but some problems may be undetectable due to problems within the walls or under the flooring.. 1. Locations Locations: Main Floor Bathroom Basement Bathroom 2. Doors
Good Fair Poor N/A None

X 3. Electrical
Good Fair Poor N/A None

Observations: No major system safety or function concerns noted at time of inspection.

X 4. GFCI
Good Fair Poor N/A None

X 5. Exhaust Fan
Good Fair Poor N/A None

Observations: GFCI in place and operational

X 6. Floor Condition
Good Fair Poor N/A None

Observations: No fan was observed, we recommend an exhaust fan be installed in all bathrooms for proper ventilation and moisture control. Materials: Ceramic tile is noted.

X 7. Plumbing
Good Fair Poor N/A None

Observations: Pressure weakens when water is running in other areas. Hot water temp is just over 130 degrees- recommend turning down water heater to achieve 120 or below temp to prevent injury.

Page 11 of 44

Metro Inspections

Orchard Road, Minnetonka, mn

8. Showers
Good Fair Poor N/A None

Observations: Low water flow observed. Loss of pressure noted when two or more fixtures are operated at the same time. Hot and cold shower valves were very hard to turn, indicating nearing the end of it's useful life. Shower enclosure downstairs needs to be cleaned and re-caulked.

9. Shower Walls
Good Fair Poor N/A None

X 10. Bath Tubs


Good Fair Poor N/A None

Observations: Ceramic tile noted. Fiberglass surround noted. Observations: Stains observed around tub drain from moisture present. Drain was not leaking on the day of inspection, but that does not mean that there isn't a situation I couldn't recreate that is causing moisture to be present.

Page 12 of 44

Metro Inspections

Orchard Road, Minnetonka, mn

11. Enclosure
Good Fair Poor N/A None

Observations: Corrosion present on the shower enclosure noted. It cannot be determined at the time of the inspection whether or not a simple cleaning will solve the problem. Observations: Nonstandard flex drain used under sink. Should be replaced with correct part by licensed plumber. Poor pressure flow when running several fixtures in one area.

12. Sinks
Good Fair Poor N/A None

13. Toilets
Good Fair Poor N/A None

X 14. Window Condition


Good Fair Poor N/A None

Observations: 0bserved as functional and in good visual condition.

Materials: Wood framed casement window noted. Observations: Deterioration noted due to contact with moisture, exhaust fan would help with this problem that will eventually destroy the window.

Page 13 of 44

Metro Inspections

Orchard Road, Minnetonka, mn

Kitchen The kitchen is used for food preparation and often for entertainment. Kitchens typically include a stove, dishwasher, sink and other appliances. 1. Cabinets
Good Fair Poor N/A None

X 2. Counters
Good Fair Poor N/A None

X 3. Dishwasher
Good Fair Poor N/A None

X 4. Doors
Good Fair Poor N/A None

X 5. Microwave
Good Fair Poor N/A None

X 6. Cook top condition


Good Fair Poor N/A None

X 7. Oven & Range


Good Fair Poor N/A None

Observations: Electric cook top noted. All heating elements operated when tested. Observations: Oven is Electric- Did not operate. Door was being held up with rope. Recommend repair, or replacement.

Page 14 of 44

Metro Inspections

Orchard Road, Minnetonka, mn

8. Sinks
Good Fair Poor N/A None

Observations: Drain line leaks under sink.

9. Vent Condition
Good Fair Poor N/A None

Observations: Hood vents in to soffit. Recommend having a professional contractor install a roof vent.

10. Window Condition


Good Fair Poor N/A None

Materials: Wood framed double hung window noted. Observations: Hardware difficult to operate at one or more locations. Recommend review and repair as needed by qualified window contractors.

Page 15 of 44

Metro Inspections

Orchard Road, Minnetonka, mn

11. Floor Condition


Good Fair Poor N/A None

X 12. Electrical
Good Fair Poor N/A None

Materials: Hardwood flooring is noted.

X 13. GFCI
Good Fair Poor N/A None

Observations: No major system safety or function concerns noted at time of inspection.

X 14. Wall Condition


Good Fair Poor N/A None

Observations: GFCI in place and operational.

Materials: Drywall walls noted.

Page 16 of 44

Metro Inspections

Orchard Road, Minnetonka, mn

Laundry 1. Locations Locations: Downstairs 2. Dryer Vent


Good Fair Poor N/A None

Observations: Irregular materials were used to create a dryer vent. Recommend replacing the vent pipe with the proper materials.

3. Electrical
Good Fair Poor N/A None

X 4. GFCI
Good Fair Poor N/A None

Observations: X The laundry receptacle should be GFCI protected type.

5. Gas Valves
Good Fair Poor N/A None

X 6. Wash Basin
Good Fair Poor N/A None

Observations: Nonstandard flex drain used under sink. Should be replaced with correct part by licensed plumber.

Page 17 of 44

Metro Inspections

Orchard Road, Minnetonka, mn

7. Floor Condition
Good Fair Poor N/A None

X 8. Plumbing
Good Fair Poor N/A None

Materials: Bare concrete floors noted.

Observations: Hot and cold water supply to the wash basin were not properly supported. Recommend having a professional contractor remedy the situation.

9. Doors
Good Fair Poor N/A None

Observations: No major system safety or function concerns noted at time of inspection.

Page 18 of 44

Metro Inspections

Orchard Road, Minnetonka, mn

Heat/AC The heating, ventilation, and air conditioning and cooling system (often referred to as HVAC) is the climate control system for the structure. The goal of these systems is to keep the occupants at a comfortable level while maintaining indoor air quality, ventilation while keeping maintenance costs at a minimum. The HVAC system is usually powered by electricity and natural gas, but can also be powered by other sources such as butane, oil, propane, solar panels, or wood. The inspector will usually test the heating and air conditioner using the thermostat or other controls. For a more thorough investigation of the system please contact a licensed HVAC service person. 1. Heater Condition Good Fair Poor N/A None Materials: The furnace is located in the laundry room X Materials: Gas fired forced hot air. Observations: Furnace was manufactured the 49th week of 1999. It is approximately at 3/4 of it's useful serviceable life.

2. Heater Base
Good Fair Poor N/A None

Page 19 of 44

Metro Inspections

Orchard Road, Minnetonka, mn

3. Enclosure
Good Fair Poor N/A None

X 4. Venting
Good Fair Poor N/A None

X 5. Gas Valves
Good Fair Poor N/A None

X 6. Refrigerant Lines
Good Fair Poor N/A None

X 7. AC Compress Condition Good Fair Poor N/A None Compressor Type: Electric X Location: The compressor is located on the exterior west. Observations: Did not operate the A/C unit because of the time of year and temperature outside.

Manufactured in July of 2007 8. Air Supply


Good Fair Poor N/A None

X 9. Registers
Good Fair Poor N/A None

Observations: The return air supply system appears to be functional.

Observations: The return air supply system appears to be functional.

Page 20 of 44

Metro Inspections

Orchard Road, Minnetonka, mn

10. Filters
Good Fair Poor N/A None

Observations: MAINTENANCE: The air filter(s) should be inspected at least monthly and cleaned or replaced as required. There are two types of filters commonly used: (1) Washable filters, (constructed of aluminum mesh, foam, or reinforced fibers) these may be cleaned by soaking in mild detergent and rising with water. Or (2) Fiberglass disposable filters that must be REPLACED before they become clogged. Remember that dirty filters are the most common cause of inadequate heating or cooling performance. Annual HVAC service contract is recommended. Disposable type filter appeared dirty. Replace as needed.

Page 21 of 44

Metro Inspections

Orchard Road, Minnetonka, mn

Water Heater 1. Base


Good Fair Poor N/A None

X 2. Heater Enclosure
Good Fair Poor N/A None

Observations: The water heater base is functional.

Observations: The water heater enclosure is functional.

3. Combusion
Good Fair Poor N/A None

X 4. Venting
Good Fair Poor N/A None

Observations: The combustion chamber appears to in functional condition.

Page 22 of 44

Metro Inspections

Orchard Road, Minnetonka, mn

5. Water Heater Condition Good Fair Poor N/A None Heater Type: Gas X Location: The heater is located in the laundry room. Observations: The hot water heater is nearing the end of its useful serviceable life. Apparent back draft potential carbon monoxide poisoning hazard. Have plumber verify proper operation. corrosion and stains present from condensation or precipitation.

6. TPRV
Good Fair Poor N/A None

X 7. Number Of Gallons
Good Fair Poor N/A None

Observations: A pressure & temperature relief valve & extension is present and appears satisfactory. Observations: 40 gallons

X 8. Gas Valve
Good Fair Poor N/A None

X 9. Plumbing
Good Fair Poor N/A None

Observations: Appears functional.

Materials: Galvanized Observations: No deficiencies observed at the visible portions of the supply piping.

10. Overflow Condition


Good Fair Poor N/A None

11. Strapping
Good Fair Poor N/A None

Page 23 of 44

Metro Inspections

Orchard Road, Minnetonka, mn

Garage 1. Roof Condition


Good Fair Poor N/A None

Materials: Roofing is the same as main structure. Materials: Asphalt shingles noted. Observations: No major system safety or function concerns noted at time of inspection. Roof is at half or more of it's expected serviceable life.

2. Walls
Good Fair Poor N/A None

X 3. Anchor Bolts
Good Fair Poor N/A None

Observations: Appeared satisfactory, at time of inspection.

Observations: X The anchor bolts were not visible.

4. Floor Condition
Good Fair Poor N/A None

Materials: Bare concrete floors noted. Observations: Large cracks across the garage floor, recommend sealing cracks/voids. Foundation is cracking and showing signs of failure. Recommend review by a qualified professional contractor before purchase of the property.

Page 24 of 44

Metro Inspections

Orchard Road, Minnetonka, mn

Page 25 of 44

Metro Inspections

Orchard Road, Minnetonka, mn

5. Rafters & Ceiling


Good Fair Poor N/A None

Observations: Dimensional lumber wood ceiling joists.

6. Electrical
Good Fair Poor N/A None

X 7. Exterior Door
Good Fair Poor N/A None

Page 26 of 44

Metro Inspections

Orchard Road, Minnetonka, mn

8. Fire Door
Good Fair Poor N/A None

9. Garage Door Condition Good Fair Poor N/A None Observations: X No deficiencies observed. 10. Garage Opener Status Good Fair Poor N/A None Observations: X Chain drive opener noted.

11. Garage Door's Reverse Status Good Fair Poor N/A None Observations: X Eye beam system present and operating.

Page 27 of 44

Metro Inspections

Orchard Road, Minnetonka, mn

Electrical 1. Electrical Panel


Good Fair Poor N/A None

Location: Main Location: North east corner in basement bedroom. Location: Located in the garage. Observations: Recommend upgrading service. Knockouts need snap-in caps inside panel box. Should be installed to keep mice out of panel box and to avoid potential electrocution hazard. Questionable wiring in panel box. Have licensed electrician evaluate. Spliced & taped wires.

Page 28 of 44

Metro Inspections

Orchard Road, Minnetonka, mn

2. Main Amp Breaker


Good Fair Poor N/A None

Observations: X 100 amp

3. Breakers in off position


Good Fair Poor N/A None

X 4. Cable Feeds
Good Fair Poor N/A None

Observations: Recommend updating main cable feeds to today's standards.

5. Fuses
Good Fair Poor N/A None

Observations: Recommend updating the service panel to circuit breakers.

Page 29 of 44

Metro Inspections

Orchard Road, Minnetonka, mn

Roof 1. Roof Condition


Good Fair Poor N/A None

Materials: Inspected from on the roof. Materials: Asphalt shingles noted. Observations: Some shingles damaged. Moss on roof. This can lead to the premature failure of the roof and subsequent leaks. Recommend treating moss during its growing season (wet months) with a moss killer. For information on various moss treatment products and their pros and cons, visit http://bryophytes.science.oregonstate.edu/page24.htm.

2. Flashing
Good Fair Poor N/A None

3. Chimney
Good Fair Poor N/A None

Page 30 of 44

Metro Inspections

Orchard Road, Minnetonka, mn

4. Vent Caps
Good Fair Poor N/A None

X 5. Gutter
Good Fair Poor N/A None

Observations: Clean gutters: Significant amounts of debris evident. Recommend directing water away from under the porch to stop erosion next to foundation.

Page 31 of 44

Metro Inspections

Orchard Road, Minnetonka, mn

Page 32 of 44

Metro Inspections

Orchard Road, Minnetonka, mn

Attic 1. Access
Good Fair Poor N/A None

Observations: Access at hallway ceiling.

2. Structure
Good Fair Poor N/A None

X 3. Ventilation
Good Fair Poor N/A None

Observations: Limited review due to insulation installed between the rafters.

X 4. Vent Screens
Good Fair Poor N/A None

5. Electrical
Good Fair Poor N/A None

X 6. Attic Plumbing
Good Fair Poor N/A None

Observations: Most areas not accessible due to insulation.

X 7. Insulation Condition
Good Fair Poor N/A None

Materials: Unfinished fiberglass batts noted. Observations: Insulation appears adequate. There is some air bypass happing around the chimney. This can create moisture in the attic leading to unwanted damage to the structure.

Page 33 of 44

Metro Inspections

Orchard Road, Minnetonka, mn

Attic bypass

8. Chimney
Good Fair Poor N/A None

Page 34 of 44

Metro Inspections

Orchard Road, Minnetonka, mn

Exterior Areas 1. Doors


Good Fair Poor N/A None

Observations: Screens on porch door, and window are damaged and need to be replaced.

2. Window Condition
Good Fair Poor N/A None

Observations: Deterioration of wooden frames noted. While basic maintenance may prolong the life of these window frames, replacement may be necessary at some point.

Page 35 of 44

Metro Inspections

Orchard Road, Minnetonka, mn

3. Siding Condition
Good Fair Poor N/A None

Materials: Composition wood siding, wood frame construction, concrete / block foundation Stone veneer noted.

Page 36 of 44

Metro Inspections

Orchard Road, Minnetonka, mn

4. Eaves & Facia


Good Fair Poor N/A None

X 5. Exterior Paint
Good Fair Poor N/A None

Page 37 of 44

Metro Inspections

Orchard Road, Minnetonka, mn

Foundation 1. Foundation Walls


Good Fair Poor N/A None

Observations: Limited review due to insulation cover and finished walls. Mold-like bio growth observed. Professional testing & evaluation advised. Efflorescence observed; this is a mineral deposit left behind from exterior water infiltration.

Efflorescence 2. Cripple Walls


Good Fair Poor N/A None

3. Foundation Electrical
Good Fair Poor N/A None

Page 38 of 44

Metro Inspections

Orchard Road, Minnetonka, mn

4. Foundation Plumbing Good Fair Poor N/A None Observations: X Plumbing vent pipe has a broken connection in the laundry room. This is a hazard because sewer gas can come directly into the house. This should be repaired by a qualified professional contractor.

5. Ducting
Good Fair Poor N/A None

Observations: No deficiencies were observed at the visible portions of the structural components of the home.

Page 39 of 44

Metro Inspections

Orchard Road, Minnetonka, mn

Grounds 1. Driveway and Walkway Condition Good Fair Poor N/A None Materials: Concrete driveway noted. Asphalt driveway noted. Concrete sidewalk noted. Observations: Driveway in good shape. Recommend sealing to extend life. Monitor: Surface deterioration observed at the concrete surface. Extensive cracks in sidewalk. Repair and / or monitor for expansion and development of trip hazards.

Page 40 of 44

Metro Inspections

Orchard Road, Minnetonka, mn

2. Grading
Good Fair Poor N/A None

Observations: Lot grading and drainage have a significant impact on the building, simply because of the direct and indirect damage that moisture can have on the foundation. It is very important, therefore, that surface runoff water be adequately diverted away from the home. Lot grading should slope away and fall a minimum of one (1) inch every foot for a distance of six (6) feet around the perimeter of the building. Low areas were observed. Backfill is recommended.

3. Patio and Porch Deck Good Fair Poor N/A None Observations: X Appeared functional at time of inspection.

Page 41 of 44

Metro Inspections

Orchard Road, Minnetonka, mn

4. Stairs & Handrail


Good Fair Poor N/A None

X 5. Grounds Electrical
Good Fair Poor N/A None

Observations: Appeared functional at time of inspection.

X 6. GFCI
Good Fair Poor N/A None

Observations: No major system safety or function concerns noted at time of inspection. Covers or globes recommended over bare light bulbs.

7. Main Gas Valve Condition Good Fair Poor N/A None Materials: West side. X Observations: Meter located at exterior. All gas appliances have cut-off valves in line at each unit. No gas odors detected.

Page 42 of 44

Metro Inspections

Orchard Road, Minnetonka, mn

8. Plumbing
Good Fair Poor N/A None

X 9. Water Pressure
Good Fair Poor N/A None

Materials: Copper piping noted. Galvanized piping noted. PVC piping noted.

Observations: Water pressure went down more than normal throughout the house when more then one fixture was operating.

10. Pressure Regulator


Good Fair Poor N/A None

Grounds Pressure Regulator 11. Exterior Faucet Condition Good Fair Poor N/A None Location: West side of house. X

Page 43 of 44

Metro Inspections

Orchard Road, Minnetonka, mn

12. Patio and Porch Condition Good Fair Poor N/A None Materials: The patio/porch roof is the same as main structure. X

Page 44 of 44