You are on page 1of 6

1. In sensible heating process, the moisture content: a. Increases b. Decreases c. Remains constant d. Indeterminate 2.

Air for comfort cooling should maintain a movement from: a. 2760 to 4570 mm/min b. 4570 to 7620 mm/min c. 7620 to 9430 mm/min d. 9430 to 12480 mm/min 3. The maximum number of persons working or will be working shall not exceed one person per a. 12 square meters b. 12 cubic meters c. 21 square meters d. 21 cubic meters 4. If the dry-bulb and wet-bulb temperatures in air are identical, the a. Dew point of air is reached b. Mixture is completely dry c. Relative humidity is zero d. None of the above 5. Which among the following do not measure relative humidity? a. Psychrometer b. Humeter c. Piezometer d. Hygrometer 6. One ton of refrigeration is equivalent to a. 3.615 kW b. 3.516 kW (original 3.165 kW) c. 200 Btu/min d. 220 Btu/min 7. Instrument used to measure moisture content of air a. Psychrometer b. Hydrometer c. Hygrometer d. Calorimeter 8. Unit used for fan capacity a. kW b. Btu/min c. kN d. m3/s 9. Study of the proportion and water vapor content of air a. Psychrometry

10.

11.

12.

13.

14.

15.

16.

17.

b. Cryogenics c. Air-conditioning d. Air treatment Actual temperature of air a. Wet-bulb temperature b. Dry-bulb temperature c. Dew-point temperature d. Boiling point The temperature where the water vapor present in air will start to condense when cooled at constant pressure. a. Wet-bulb temperature b. Dry-bulb temperature c. Dew-point temperature d. Ambient temperature In psychrometric chart, the diagonal lines represent a. Wet-bulb temperature b. Dry-bulb temperature c. Dew-point temperature d. Ambient temperature Combined process of cooling and humidifying a. Evaporative cooling b. Sensible cooling c. Heating and humidifying d. Sensible heating Specific measurement of moisture content of air a. Degree of saturation b. Percent saturation c. Specific humidity d. Relative humidity Process occurring in an air-conditioning unit a. Sensible cooling b. Heating and humidifying c. Adiabatic saturation d. Cooling and dehumidifying Temperature of saturated air a. Dry-bulb temperature b. Wet-bulb temperature c. Dew-point temperature d. Ambient temperature Which of the following is a function of air-conditioning? a. Control of temperature b. Control of humidity

18.

19.

20.

21.

22.

23.

24.

25.

c. Control of purity d. All of the above Achievement of temperature below that of the surrounding temperature a. Air conditioning b. Refrigeration c. Ventilation d. Cooling and humidifying What amount of air is required in a low bypass factor? (ME Board) a. Greater b. Lesser c. Indeterminate d. Does not change What is the term used to express the ratio of specific humidities, actual versus saturated? a. Relative humidity b. Absolute humidity c. Degree of saturation d. Percent saturation Dew point is defined as: a. The temperature to which the air must be cooled at constant pressure to produce saturation. b. The point where the pressure and temperature lines meet c. The temperature which dew is formed in the air d. The pressure which dew is formed in the air The design of an air supply duct of an air conditioning system: a. Adds moisture to the air b. Lowers the temperature of the air c. Does not affect the distribution of air d. Affects the distribution of air The psychrometric chart in air conditioning determines the: a. Wet bulb and dry bulb temperatures b. Psychrometric temperature requirements c. Saturation temperature requirements d. Moist air conditions In sensible heating, cooling, following parameter remains unchanged: a. Dry bulb temperature b. Wet bulb temperature c. Relative humidity d. Humidity ratio Sensible heat: a. Can be measured with a thermometer b. Cannot be measured with a thermometer c. Changes in the receiver tank

26.

27.

28.

29.

30.

31.

32.

33.

d. Increases with the cold A ton of refrigeration is equal to the cooling effect of: a. 2000 lbs of ice melting in 24 hrs b. 2000 lbs of ice melting in 12 hrs c. 2000 lbs of water being converted to ice d. 2240 lbs of ice melting in 24 hrs When there is a reduction in humidity ratio, it means: a. Humidifying b. Subcooling c. Dehumidifying d. Reheating What is the relative humidity of dry air? a. 150% b. 100% c. 50% d. 0% Room air conditioning needs abundant supply of air, because it uses what type of condenser? a. Chilled water system b. Water cooled c. Shell and tube d. Air cooled The relative humidity become 100% and where the water vapor starts to condense. a. Dew point b. Wet bulb c. Dry bulb d. Saturated What is that one main part of an equipment, through the air movement of the ventilation, heating, refrigerating and also used to discharge to the ventilating outlet? a. Duct b. Dehumidifier c. Blower d. Strainer Moisture content of air is equal to the content of dry air at 100% relative humidity. If further, there are some moisture drop caused by: a. Condensation of some of the moistures of refrigerant b. Evaporation of some of the moistures of refrigerant c. Condensation of some of the moistures of air d. Evaporation of some of the moistures of air The latent heat of air is a function of _____ temperature a. Dew point b. Dry bulb c. Wet bulb

34.

35.

36.

37.

38.

39.

40.

41.

d. Absolute Dew point is which of the following? a. Adiabatic saturation temperature b. Temperature at 50% RH c. Temperature of grains of moisture per lb of bone dry air d. Wet bulb temperature As an engineer, you are advised to design the air conditioning system for a ballroom dancing hall. Considering that this involve a lot of activity from its occupants, you are to design that will require a. Constant effective temperature b. Lower effective temperature c. Higher effective temperature d. Maximum effective temperature The comfort index where the effect of ambient temperature is combined with the humidity. a. Affective temperature b. ASHRAE comfort index c. Effective temperature d. None of these An air conditioning system wherein the entire system are mounted in the cabinet a. Console air conditioner b. Centralized air conditioner c. Multizone split ductless system d. Package type air conditioner In sensible heating the absolute humidity remains constant but the relative humidity a. Zero b. Remains constant c. Decreases d. Increases Air is delivered to the room from the supply duct moving at a velocity of 150 m/min or more is called: a. Primary air b. Secondary air c. Saturated air d. Air turbulence An air conditioning system which is a combination of heating and cooling system which is designed to serve individual room or zone. a. Console air conditioner b. Window type air conditioner c. Packaged terminal air conditioner d. All of the above When coil surface temperature is below the dew point of the air a. Air is dehumidified

b. Moisture will condense out the air c. Air is humidified and saturated d. All of the above 42. What is the value of air stratification in air conditioning design fitted for human being. a. Minimum b. Maximum c. Less than air temperature d. None of the above 43. The relationship of water vapor in the air at the dew point temperature to the amount that would be in the air if the air were saturated at the dry bulb temperature. a. Percentage humidity b. Relative humidity c. Partial pressure of water d. All of the above 44.

You might also like