1.

2.

PREPARATION ........................................................................................................................................... 3
1.1.

HARDWARE REQUIREMENTS ....................................................................................................................... 3

1.2.

SOFTWARE REQUIREMENTS ....................................................................................................................... 4

1.3.

FILE PREPARATION .................................................................................................................................... 4

PROCEDURE............................................................................................................................................... 5

CAUTIONTHE RADIO LINK CONNECTION CUTS FOR A FEW MINUTES. ................................................ 5


2.1.

NETWORK SETTING ..................................................................................................................................... 5

2.2.

IDU POWER ON ......................................................................................................................................... 5

2.3.

CONFIRMATION OF CONNECTION .................................................................................................................. 5

2.4.

LCT LOGIN ................................................................................................................................................ 6

2.5.

CONFIRMATION OF VERSION INFORMATION .................................................................................................... 7

2.6.

MAINTENANCE MODE SETTING.................................................................................................................. 8

2.7.

FIRM WARE UPDATE MODE ........................................................................................................................... 9

2.8.

ODU SELECT............................................................................................................................................ 10

2.9.

LOCAL PC SELECT .................................................................................................................................... 11

2.10.

FILE SELECT ............................................................................................................................................. 12

2.11.

CONFIRM THE RADIO DISCONNECTION ......................................................................................................... 14

2.12.

REACTIVATION OF IDU .............................................................................................................................. 15

2.13.

CONFIRMATION OF VERSION INFORMATION .................................................................................................. 16

2.14.

MAINTENANCE MODE SETTING................................................................................................................ 17

2.15.

FIRM WARE UPDATE MODE ......................................................................................................................... 18

2.16.

ODU SELECT............................................................................................................................................ 19

2.17.

LOCAL PC SELECT .................................................................................................................................... 20

2.18.

FILE SELECT ............................................................................................................................................. 21

2.19.

CONFIRM THE RADIO DISCONNECTION ......................................................................................................... 23

2.20.

REACTIVATION OF IDU .............................................................................................................................. 24

2.21.

CONFIRMATION OF VERSION INFORMATION .................................................................................................. 25

2.22.

MAINTENANCE MODE SETTING................................................................................................................ 26

2.23.

FIRM WARE UPDATE MODE ......................................................................................................................... 27

2.24.

ODU SELECT............................................................................................................................................ 28

2.25.

LOCAL PC SELECT .................................................................................................................................... 29

2.26.

FILE SELECT ............................................................................................................................................. 30

2.27.

CONFIRM THE RADIO DISCONNECTION ......................................................................................................... 32

2.28.

ROM SWITCHING ..................................................................................................................................... 33

2.29.

CONFIRMATION OF VERSION INFORMATION .................................................................................................. 35

ODU Program File Update Procedure

ver.0.1

NEC Confidential

Preparation
Operator
LAN cable
LCT Port

iPASOLINK 200
IP address: DHCP

Fig. 1:ODU ProgramFile Update Diagram

1.1. Hardware Requirements


Windows XP
Required
CPU

Pentium M 1.6GHz

RAM

512MB

HDD

40GB

Display

Color LCD (1024 x 768)

LAN Port

10/100BASE-T(X)

Windows Vista
Required
CPU

Intel Core2 Duo 1.6GHz

RAM

1GB

HDD

40GB

Display

Color LCD (1024 x 768)

LAN Port

10/100BASE-T(X)

Windows 7
Required
CPU

Intel Core2 Duo 1.6GHz

RAM

1GB

HDD

40GB

Display

Color LCD (1024 x 768)

LAN Port

10/100BASE-T(X)
3

ODU Program File Update Procedure

ver.0.1

NEC Confidential

1.2. Software Requirements


OS : Windows XP (English version), Windows Vista (English version), Windows 7 (English version)
IE8, Firefox3.6 or higher.

1.3. File preparation


Copy Program update file " NWZ-055266-001_NHG2+IHG_v4050-33E2.HEX "
and NWT-026820-001_NHG2_AMR-Patch_v1.hex to local PC.

ODU Program File Update Procedure

ver.0.1

NEC Confidential

2. Procedure
CautionThe radio link connection cuts for a few minutes.
2.1. Network setting
TCP/IP setting follows Fig.2 (In case of Windows XP). Please follow the operation system about the method of
IP address and DNS server address setting.

Fig. 2: Setting of IP address on Host PC (Windows XP)

2.2. IDU Power ON


Turn on the power supply of IDU. You can access to IDU in about five minutes.

2.3. Confirmation of connection


When IDU and operation PC connections are established, the following screen is displayed. (In case of
Windows XP)

Fig. 3: Check PC LAN port is linked up(Windows XP).


5

ODU Program File Update Procedure

ver.0.1

NEC Confidential

2.4. LCT login

2. Input "http://172.17.254.253/weblct/"

3. Input User Name : Admin"


3. Input Password : 12345678"

4. Click

Fig. 4: LCT login (Internet Explorer).

1. Start up web browser.


2. Input the following address.
http://172.17.254.253/weblct/
3. Input the User name and Password.
Default User name and Password are the following.
User name : Admin
Password : 12345678
4. Then, click the OK button.

ODU Program File Update Procedure

ver.0.1

NEC Confidential

2.5. C onfirmation of version information

1. Select
3. Select

4. Confirm

2. Select

Fig. 5: Confirm Hardware Ver.


1. Select the Inventory.
2. Select the Equipment Inventory Information.
3. Select the ODU.
4. Confirm the Hardware Vesion.

or

If the second digit is 1, then go to item 2.6.


If the second digit is A, then go to item 2.14.

ODU Program File Update Procedure

ver.0.1

2.6. Maintenance mode setting

1. Click

2. Confirm

Fig. 6: Maintenance mode

1. Click to Maintenance button.


2. Confirm the display changes into Orange.

NEC Confidential

ODU Program File Update Procedure

ver.0.1

2.7. Firm ware update mode

4. Click
3. Select

1. Select
2. Select

Fig. 7: Program File Update menu

1. Select the Equipment Utility.


2. Select the Update(Strage -> NE) Utility.
3. Select the Program File".
4. Click the Execute

NEC Confidential

ODU Program File Update Procedure

ver.0.1

2.8. ODU select

1. Select

2. Click

Fig. 8: Select the ODU menu


1. Select the ODU in pull down menu.
2. Click the Next> button.

3. Select

4. Click

Fig. 9: Select the ODU (No.1) menu


3. Select the ODU (No.1) in pull down menu.
4. Click the Next> button.

10

NEC Confidential

ODU Program File Update Procedure

ver.0.1

2.9. Local PC select

1. Select
2. Click

Fig. 10: Select Local PC


1. Select the Local PC.
2. Click the Folder button.

11

NEC Confidential

ODU Program File Update Procedure

ver.0.1

2.10. File select

1. Select

2. Click

Fig. 11: Select Program file.


1. Select the NWT-026820-001_NHG2_AMR-Patch_v1.hex file.
2. Click the Open button.

12

NEC Confidential

ODU Program File Update Procedure

ver.0.1

3. Click

Fig. 12: Program file select complete


3. Then, click the OK button.

13

NEC Confidential

ODU Program File Update Procedure

ver.0.1

NEC Confidential

2.11. Confirm the radio disconnection

1. Click

Fig. 13: Confirm disconnection

1. Click the OK button.


The radio signal stops when the OK button is clicked. Then, the upgrade of FW is begun,
and it will complete in about 2 minutes.
Wait for about 2 minutes.

Fig. 14: Waiting screen

14

ODU Program File Update Procedure

ver.0.1

2. Click

Fig. 15: Comprete screen

2. If the update of Programfile is completed, LCT displays above screen.


Then, click the OK button.
3. Wait for 1 minute and go to next item.

2.12. Reactivation of IDU

Fig. 16: Unplug Power supply cable

1. Unplug Power supply cable and wait 5 seconds.


2. Turn on the power supply of IDU.
You can access to IDU in about 5 minutes.

15

NEC Confidential

ODU Program File Update Procedure

ver.0.1

NEC Confidential

2.13. Confirmation of version information


Login to IDU. (Refer to chapter 2.4)

1. Select
3. Select

4. Confirm

2. Select

Fig. 17: Confirm Hardware Ver.


1. Select the Inventory.
2. Select the Equipment Inventory Information.
3. Select the ODU.
4. Confirm the second digit of the Hardware Vesion is A.

16

ODU Program File Update Procedure

ver.0.1

2.14. Maintenance mode setting

1. Click

2. Confirm

Fig. 18: Maintenance mode

1. Click to Maintenance button.


2. Confirm the display changes into Orange.

17

NEC Confidential

ODU Program File Update Procedure

ver.0.1

2.15. Firm ware update mode

4. Click
3. Select

1. Select
2. Select

Fig. 19: Program File Update menu

1. Select the Equipment Utility.


2. Select the Update(Strage -> NE) Utility.
3. Select the Program File".
4. Click the Execute

18

NEC Confidential

ODU Program File Update Procedure

ver.0.1

2.16. ODU select

1. Select

2. Click

Fig. 20: Select the ODU menu


1. Select the ODU in pull down menu.
2. Click the Next> button.

3. Select

4. Click

Fig. 21: Select the ODU (No.1) menu


3. Select the ODU (No.1) in pull down menu.
4. Click the Next> button.

19

NEC Confidential

ODU Program File Update Procedure

ver.0.1

2.17. Local PC select

1. Select
2. Click

Fig. 22: Select Local PC


1. Select the Local PC.
2. Click the Folder button.

20

NEC Confidential

ODU Program File Update Procedure

ver.0.1

2.18. File select

1. Select

2. Click

Fig. 23: Select Program file.


1. Select the NWZ-055266-001_NHG2+IHG_v4050-33E2.HEX file.
2. Click the Open button.

21

NEC Confidential

ODU Program File Update Procedure

ver.0.1

3. Click

Fig. 24: Program file select complete


3. Then, click the OK button.

22

NEC Confidential

ODU Program File Update Procedure

ver.0.1

NEC Confidential

2.19. Confirm the radio disconnection

1. Click

Fig. 25: Confirm disconnection

1. Click the OK button.


The radio signal stops when the OK button is clicked. Then, the upgrade of FW is begun,
and it will complete in about 5 minutes.
Wait for about 5 minutes.

Fig. 26: Waiting screen


23

ODU Program File Update Procedure

ver.0.1

2. Click

Fig. 27: Comprete screen

2. If the update of Programfile is completed, LCT displays above screen.


Then, click the OK button.
3. Wait for 1 minute and go to next item.

2.20. Reactivation of IDU

Fig. 28: Unplug Power supply cable

3. Unplug Power supply cable and wait 5 seconds.


4. Turn on the power supply of IDU.
You can access to IDU in about 5 minutes.

24

NEC Confidential

ODU Program File Update Procedure

ver.0.1

2.21. C onfirmation of version information


Login to IDU. (Refer to chapter 2.4)

1. Select
3. Select

4. Confirm

2. Select

Fig. 29: Confirm Program File Ver.

1. Select the Inventory.


2. Select the Equipment Inventory Information.
3. Select the ODU.
4. Confirm the Current F/W version.

25

NEC Confidential

ODU Program File Update Procedure

ver.0.1

2.22. Maintenance mode setting

1. Click

2. Confirm

Fig. 30: Maintenance mode

1. Click to Maintenance button.


2. Confirm the display changes into Orange.

26

NEC Confidential

ODU Program File Update Procedure

ver.0.1

2.23. Firm ware update mode

4. Click
3. Select

1. Select
2. Select

Fig. 31: Program File Update menu

1. Select the Equipment Utility.


2. Select the Update(Strage -> NE) Utility.
3. Select the Program File".
4. Click the Execute

27

NEC Confidential

ODU Program File Update Procedure

ver.0.1

2.24. ODU select

1. Select

2. Click

Fig. 32: Select the ODU menu


1. Select the ODU in pull down menu.
2. Click the Next> button.

3. Select

4. Click

Fig. 33: Select the ODU (No.1) menu


3. Select the ODU (No.1) in pull down menu.
4. Click the Next> button.

28

NEC Confidential

ODU Program File Update Procedure

ver.0.1

2.25. Local PC select

1. Select
2. Click

Fig. 34: Select Local PC


1. Select the Local PC.
2. Click the Folder button.

29

NEC Confidential

ODU Program File Update Procedure

ver.0.1

2.26. File select

1. Select

2. Click

Fig. 35: Select Program file.


1. Select the NWZ-055266-001_NHG2+IHG_v4050-33E2.HEX file.
2. Click the Open button.

30

NEC Confidential

ODU Program File Update Procedure

ver.0.1

3. Click

Fig. 36: Program file select complete


3. Then, click the OK button.

31

NEC Confidential

ODU Program File Update Procedure

ver.0.1

NEC Confidential

2.27. Confirm the radio disconnection

1. Click

Fig. 37: Confirm disconnection

1. Click the OK button.


The radio signal stops when the OK button is clicked. Then, the upgrade of FW is begun,
and it will complete in about 5 minutes.
Wait for about 5 minutes.

Fig. 38: Waiting screen

32

ODU Program File Update Procedure

ver.0.1

NEC Confidential

2.28. ROM Switching

1. Click
2. Click

Fig. 39: Confirm Program ROM Switching

If the update of FW is completed, LCT displays above screen.


1. Then, check the Program ROM Switching box and,
2. Click the OK button.

3. Click

Fig. 40: Confirm disconnection

3. Click the OK button.


CautionThe radio link connection cuts for a few minutes.

33

ODU Program File Update Procedure

ver.0.1

4. Click

Fig. 41: Comprete screen


4. Click the OK button.

5. Click

Fig. 42: Previous screen


5. Click the Cancel button.

34

NEC Confidential

ODU Program File Update Procedure

ver.0.1

2.29. C onfirmation of version information

1. Select
3. Select

4. Confirm

2. Select

Fig. 43: Confirm Program File Ver.

1. Select the Inventory.


2. Select the Equipment Inventory Information.
3. Select the ODU.
4. Confirm the Current F/W version and Uncurrent F/W version are same value.

35