Inverter Packaged Air Conditioners

MHIAA is proudly sponsoring Monikas Doggie Rescue

FD Series.
Inverter Packaged Air Conditioners.

change setting by button taps only

Run / Stop High power operation


Maximum capacity operation (Max 15 minutes) Increased compressor speed Increased air flow

Energy-saving operation
Changes set temperature at 28C in cooling mode and 22C in heating mode, 25C in auto mode. Operation correction by outdoor temperature

Main functions
Energy management
Peak cut timer Automatic temperature set back Weekly timer Set ON/OFF timer by hour Set ON/OFF timer by clock Fan only operation Sleep timer

Comfort
Individual flap control High power operation External ventilation ON/OFF Warm up operation Automatic fan speed Temperature increment setting by 0.5C

FD series Inverter Packaged Air Conditioners 2013

Advanced touch screen panel with full dot Liquid Crystal Display

PRODUCTS

Basic operation
Operation mode setting screen

All settings are changed by tapping the touch screen panel

The operation mode can be selected by simply tapping this button.

Temperature setting screen

You can select the desired temperature by tapping the button.

Operation mode
Cooling Dry Auto Fan Heating

Convenience
LCD contrast setting Back light setting Filter clean sign Control sound Outdoor silent mode Summer time setting Home leave mode Indoor & outdoor temperature display Heating standby display Defrosting operation display Auto cooling/heating display C/F display Administrator settings Room name setting

Service
Error code display Operation data display Next service data display Contact company display USB connection (mini-B)

FD Series.
Hyperinverter.

Our advanced technology has allowed us to achieve high efficiency, powerful heating and long distance refrigerant piping specifications. This feature permits installation of the units when a heating operation under temperature conditions down to -20C is required. Design flexibility has been improved by an extension of the refrigerant piping length to 100m (12.5 & 14.0kW).

Blue Fin
5.0 & 6.0kW

Micro
Blue Fin

7.1kW

10.0kW

12.5 & 14.0kW

Long piping
(in case of 12.5 & 14.0kW)

Strong heating
(in case of 7.1~14.0kW)

Height difference
(Outdoor higher than Indoor)

-20C -15C

: Heating operation down to -20C : Nominal heating capacity maintained at -15C


Heating Cooling
-10 0 10 20 30 40

-20C

+20C +43C

Piping length

30m

-15C
-30 -20

100m

50

FD series Inverter Packaged Air Conditioners 2013

Heating capacity
(kW)

Heating capacity

Temperature of supply air can reach 40C 4 minutes after 18.0 Keeping nominal heating starting up under low temperature operation conditions Hyper Inverter capacity at -15C 14.5 nominal (at and can 14.0 both indoor and outdoor temperature of 2C) heating capacity reach 50C 8 minutes after that. 14.0kW
8.8 0

Heating capacity (in case of 12.5kW)

PRODUCTS

50C 40C 30C 20C 10C 0C

Hyper Inverter

Micro Inverter
-15C 2C 7C

Micro Inverter
4minutes 8minutes

Micro Inverter
Compact design of outdoor units

FDC100VN 10.0kW
Reduction in height by 22.3%
* Vector control: To convert the current wave to a smooth sinusoidal waveform.

Our single fan micro 10.0kW condenser is one of the most Reduction in volume by 44.1% compact in the industry being only 845(h)x970(w)x370(d)
Height at 342mm

ameter of shell 5mm

Outside diameter of shell 185mm

133mm

Former compressor

New model DC rotary compressor Former model

Height at 342mm

rmer pressor

The DC twin rotary compressor can operate New model DC rotary compressor at speeds as high as 120 rps to achieve the required capacity. Vector control provides perfect compressor control. Starting current has reduced significantly and vibration has been minimized.

Height at 440 mm

Size reduction and high ef ciency performance of the DC twin rotary compressor

133mm

Reduction in height by 22.3% Reduction in volume by 44.1%

* Vector control: To convert the current wave to a smooth sinusoidal waveform.

Current model

Improved ef ciency of the heat exchanger


Re-designing the fins to a straight shape has reduced the pressure loss of the air flow in the heat exchanger. A new surface treatment on the fins has enhanced the frost resistance capacity compared to former models. A high speed fan motor has increased the airflow which allows cooling capacity to be maintained even at high outdoor air temperatures.

Protection
Improved operation of the electronic expansion valve allows for more reliable oil return and this assists to protect the compressor.
Former model Current model

FDT-FDTC.
Ceiling Cassette - 4way - Indoor units.
Individual ap control system
Individual flap control is available even after installation. This means that the installation area has become wider than before. The outlet design has been perfected to allow sufficient air flow that can reach a long distance from the indoor unit.

Previous
Previous

Current
Current

Flap control system


The design of the heat exchanger has changed from 2 parts to a single piece. The height of the indoor unit has been reduced significantly.
*RCH-E3 is not applicable to the Individual flap control system and the Flap control system.
Upper position

Upper position
Upper position

Previous

Current

Movable range

Movable Lower range position Lower position

Movable range Lower position

For person who is far


For person who is far unit from the indoor from the indoor unit

The thinnest design


FDT125~140 The design of the heat exchanger FDT125~140 has changed from 2 parts to 1 part, the height of indoor unit is reduced. DC fan motors are used to increase efficiency. Weight has been reduced FDT125~140 and as a result the unit has become one of the most compact in the industry.

reduction!!
365mm

18% reduction!!
365mm

18%

For person who is far from the indoor unit

298 reduction!! 298 mm


mm
365mm

18%

For both persons who are feeling hot or cold feeling hot or cold

For both persons who are

FDT71 FDT71

9% For both persons who are 9% 298 reduction!! reduction!!


mm

Shape of heat heatexchanger exchanger Shape of


Previous Previous Current Current
FDT71

feeling hot or cold

270mm 270mm

246 9% 246 mmmm reduction!!


270mm

Shape of heat exchanger

Can Can cool cool both both the kitchen the kitchen and the andguests the guests

FD series Inverter Packaged Air Conditioners 2013

Previous

Current

246
mm

Can cool both the kitchen and the guests

FDUA Indoor Unit.


Duct Connected - High Static Pressure.
PRODUCTS

External static pressure (E.S.P.) control


Selecting the external static pressure setting the optimum air flow volume can be achieved. The indoor unit will recognize the external static pressure setting and keep rated air volume.

Duct

New FDUA

Duct Ceiling

Longer Duct

Keep the same air ow volume

Setting No. E.S.P. (Pa)

10 11 12 13 14 15 16 17 18 19

E.S.P. button

10 20 30 40 50 60 70 80 90 100 110 120 130 140 150 160 170 180 200

External static pressure can be set by E.S.P. button.

Improved servicing
Fan unit (impeller and motor) can be pulled out from the right side of the unit. Maintenance access is available from both the right side and below the unit.

Improved servicing

Pipe Unit Maintenance hole Service space Fan unit

FDUA Indoor Unit.


Duct Connected - High Static Pressure.
Wired Remote Control Wireless Remote Control

RC-EX1A

RC-E5

RCH-E3

RCN-KIT3-E

Wired Remote Control

RC-EX1A
FDUA71~160VF

RC-E5

RCH-E3

Dimension
H 398 H 280

FDUA100/125/140/160VF

FDUA71VF

200 Duct dimension

600mm Drain Pump


Drain can be discharged upwards by 600mm from the ceiling surface. It allows a piping layout with a high degree of freedom depending on the installation location.

(1) Indoor units Model FDUA71VF


65 41 740 Duct dimension 185
Symbol A Gas piping B Liquid piping C1 Drain piping Drain piping C2 Gravity drainage D Hole for wiring E Suspension bolts F Inspection hole

Unit:mm
Content 15.88 5 8" Flare 9.52 3 8" Flare VP25 I.D.25,O.D.32 VP20 I.D.20,O.D.26 M10 450X450

39

Return air duct

Drain hose piece Accessory Installed on site

Control box

620

Suspension bolts pitch

less than 600mm

472

69

C1 B A
Max. drain lift

135

Note 1 The model name label is attached on the lid of the control box.

58 67
Duct dimension

30

E
Air supply duct

295 325

635 510 471 413

or more

600

Flexible hose

28

Inspection hole

1300

or more

100

Hanger plate for suspension bolt

18

986 Suspension bolts pitch 950

18 284 82

Case 2

From bottom of unit

30

600 or less

Under 60

D
55 880 Duct dimension 55

C2

280 250

170

76

175

105

43

15

467

FD series Inverter Packaged Air Conditioners 2013

FDUA
FDUA71VNXVF Indoor Outdoor Power supply Capacity Outdoor Unit Cooling T1 Heating H1 Heating H2 Input EER COP Sound pressure level (JIS C9612) Sound power level (JIS C9612) Air ow External Static Pressure External dimensions (HXWXD) Net weight Indoor Outdoor Indoor Outdoor Liquid line Refrigerant piping Gas line Connection method Quantity Refrigerant R410A Maxium Pipe Length Supply Air Connection Return Air Connection Controller Pre charged to pipe length kg m m mm mm 2.95 30 50 170 x 880 200 x 740 3.8 30 50 mm Cooling T1 Heating H1 Cooling T1 Heating H1 Indoor Outdoor Outdoor Indoor dB(A) l/s Pa 280 x 950 x 635 750 x 880(+88) x 340 34 60 9.52 15.88 398 x 1150 x 650 845 x 970 x 370 52 81 9.52 15.88 398 x 1150 x 650 1300 x 970 x 370 52 105 9.52 15.88 Flare Connection 4.5 30 100 4.5 30 100 348 x 898 348 x 898 RC-E5, RC-EX1A or RCN-KIT3-E 4.5 30 100 dB(A) kW kW 7.1 (3.2-8.0) 8.0 (3.6-9.0) 5.9 2.22 2.22 3.20 3.60 P-Hi:38 Hi:33 Me:29 Lo:25 51 66 P-Hi: 400 Hi: 317 Me: 250 Lo: 167 10 (4.0-11.2) 11.2 (4.0-12.5) 10.0 3.05 2.87 3.28 3.90 P-Hi:43 Hi:42 Me:40 Lo:37 49 70 P-Hi:650 Hi:600 Me:550 Lo:483 FDUA71VF FDC71VNX FDUA100VNVF FDUA100VF FDC100VN FDUA100VNXVF FDUA100VF FDC100VNX 1 Phase 230V 50Hz 10 (4.0-11.2) 11.2 (4.0-12.5) 13.5 2.85 2.74 3.51 4.09 P-Hi:43 Hi:42 Me:40 Lo:37 48 70 P-Hi:650 Hi:600 Me:550 Lo:483 200 398 x 1150 x 650 1300 x 970 x 370 52 105 9.52 15.88 398 x 1150 x 650 1300 x 970 x 370 52 105 9.52 15.88 398 x 1150 x 650 1505 x 970 x 370 52 140 12.7 22.22 Brazed 7.2 30 70 12.5 (5.0-14.0) 14.0 (4.0-17.0) 14.0 3.83 3.68 3.26 3.80 P-Hi:45 Hi:43 Me:41 Lo:37 48 70 P-Hi:717 Hi:650 Me:600 Lo:500 14.0 (5.0-14.5) 16.0 (4.0-18.0) 15.0 4.44 4.41 3.15 3.63 P-Hi:47 Hi:46 Me:43 Lo:40 49 72 P-Hi:850 Hi:800 Me:700 Lo:600 FDUA125VNXVF FDUA125VF FDC125VNX FDUA140VNXVF FDUA140VF FDC140VNX FDUA160VSVF FDUA160VF FDCA160VS 3 Phase 415V 50Hz 16.0 (7.0-20.0) 18.0 (7.6-22.4) 15.0 5.02 4.96 3.19 3.63 P-Hi:49 Hi:48 Me:45 Lo:42 57 74 P-Hi:850 Hi:800 Me:700 Lo:600

PRODUCTS

kg mm

Models FDUA100VF, 125VF, 140VF


Duct dimension

Model FDUA160VF
111 26 898 Duct dimension 181
Symbol A B Content Connecting position of the attached connecting pipe gas side Connecting position of the attached connecting pipe liquid side Drain piping Drain piping Gravity drainage Hole for wiring Suspension bolts Inspection hole Connecting position of the local pipe. liquid side Connecting position of the local pipe. gas side 15.88 5 8" 9.52 3 8"

Unit:mm
Flare Flare

Duct dimension

111 26

898 Duct dimension

181

Unit:mm
Symbol A Gas piping B Liquid piping C1 Drain piping Drain piping C2 Gravity drainage D Hole for wiring E Suspension bolts F Inspection hole Content 15.88 5 8" Flare 9.52 3 8" Flare VP25 I.D.25,O.D.32 VP25 I.D.25,O.D.32

348

348

C1 C2 Return air duct Drain hose piece Accessory Installed on site D E F G H

VP25 I.D.25,O.D.32 VP25 I.D.25,O.D.32 M10 450X450 12.7 1 2" 22.22 7 8" Flare Brazing

Return air duct

Drain hose piece Accessory Installed on site Suspension bolts pitch

M10 450X450

24

24

Suspension bolts pitch

Hanger plate for suspension bolt

1185 17.5

1185 17.5

Suspension bolts pitch

1150

or more

17.5 284 82
Control box

Case 2

From bottom of unit


100

1150

28

1500

Control box

1500

Suspension bolts pitch

69

C1 B A
Max. drain lift

Inspection hole

or more

472

472

600

650

69

C1 B A

Inspection hole

650

150

Duct dimension

Duct dimension

Air supply duct

295 325

Air supply duct

295 325 215

24

24

15

15

Max. drain lift

61 74

Hanger plate for suspension bolt

40

650 531 498 458

40

61 74

Notes 1) The model name label is attached on the lid of the control box. (2) Connect the piping with local pipe by using the pipe of the attachment. Liquid side and Gas side

150

40

650 531 498 458

Under 60

398 370 248 172

Under 60

348

600

D C2
111 898 Duct dimension 181

506

111

898 Duct dimension

182 181 192

C2

H D

600

398 370 248 172

or less

348

or less

215

506

Note 1 The model name label is attached on the lid of the control box.

Outline drawing (Unit:mm)


Model FDUM50VF Models FDUM60,71VF

or more

600

or more

28

17.5 284 86

Case 2

From bottom of unit


100

40

10

FDUM Indoor Unit.


Duct Connected - Medium Static Pressure.
Wired Remote Control Wireless Remote Control

RC-EX1A

RC-E5

RCH-E3

RCN-KIT3-E

Wired Remote Control

FDUM50 ~ 140VF

RC-EX1A

RC-E5

RCH-E3

600mm Drain Pump


Drain can be discharged upwards by 600mm from the ceiling surface. It allows a piping layout with a high degree of freedom depending on the installation location.
Flexible hose less than 600mm

Thin design
The height of all FDUM models is only 280mm.
70mm less
H 350

19mm less
H 299

H 280 FDUM100/125/140VF

H 280 FDUM50/60/71VF

FDUM50VF Model FDUM50VF


Symbol Duct dimension Content Gas piping Liquid piping Drain piping Drain piping Gravity drainage Hole for wiring Suspension bolts Outside air opening for ducting Air outlet opening for ducting Inspection hole 12.7 1 2" Flare 6.35 1 4" Flare VP20 standard:I.D.20, O.D.26 or VP25 Used with attached socket:I.D.25, O.D.34 Note 2 VP20 standard:I.D.20, O.D.26 or VP25 Used with attached socket:I.D.25, O.D.34 M10

FDUM60VF Model FDUM60VF


A B C1 Drain hose piece Accessory Installed on site

Duct dimension

65 46 41 31

660 Duct dimension 200 200 200

65 46

65 46 41 31 200

860 Duct dimension 4 200=800

65 46
Drain hose piece Accessory Installed on site

Symbol A Gas piping B Liquid piping Drain piping C1

Content 12.7 1

2" Flare

C2 D E F G H

39

12 4 Holes for tapping screw

Return air duct

150 Knock out 125 Knock out 450X450

14 4 Holes for tapping screw

Return air duct

786
Hanger plate for suspension bolt

Suspension bolts pitch

18

750

28

28

18 284 81
Control box

Notes 1 The model name label is attached on the lid of the control box. 2 Prepare the connecting socket VP20 or VP25 on site.
4 4 Holes for tapping screws

986
Hanger plate for suspension bolt

Suspension bolts pitch

18

950

18 284 81
Control box

6.35 1 4" Flare VP20 standard:I.D.20, O.D.26 or VP25 Used with attached socket:I.D.25, O.D.34 Note 2 Drain piping VP20 standard:I.D.20, O.D.26 or VP25 C2 Gravity drainage Used with attached socket:I.D.25, O.D.34 D Hole for wiring E M10 Suspension bolts Outside air opening F 150 Knock out for ducting Air outlet opening 125 Knock out G for ducting H 450X450 Inspection hole Notes 1 The model name label is attached on the lid of the control box. 2 Prepare the connecting socket VP20 or VP25 on site. 4 4 Holes for tapping screws 4 4 Holes for tapping screws

200

170

200

31

39

31

170

152

262

472

472

Suspension bolts pitch

Suspension bolts pitch

139

69

C1

69

C1

170
Hole

Duct dimension

View M
Max. drain lift

Duct dimension

30

Air supply duct

105

43

or less

600 or less

D
55 680 Duct dimension 55

280 250 175

170

D
55 880 Duct dimension 55

50

76

C2

280 250

600

170

50

76

175

15

105

43

15

295 325

635 510 471 413

30

E
Air supply duct

295 325

Max. drain lift

58 67

B A

113

135

170
Hole

90

170

58 67

B A

F
30

G View M

135

90

170

635 510 471 413

467

C2

467

Outline drawing (Unit:mm)


Model FDUM50VF

FD series Inverter Packaged Air Conditioners 2013

113 30

124

139

152

262

4 4 Holes for tapping screws

124

FDUM
FDUM50ZJXVF Indoor Outdoor Power supply Capacity Outdoor Unit Cooling T1 Heating H1 Heating H2 Input EER COP Sound pressure level (JIS C9612) Sound power level (JIS C9612) Air ow External Static Pressure External dimensions (HXWXD) Net weight Indoor Outdoor Indoor Outdoor Liquid line Refrigerant piping Gas line Connection method Quantity Refrigerant R410A Maxium Pipe Length Supply Air Connection Return Air Connection Controller Pre charged to pipe length kg m m mm mm 1.5 15 30 170 x 680 200 x 660 1.5 15 30 170 x 880 200 x 860 2.95 30 50 170 x 880 200 x 860 mm Cooling T1 Heating H1 Cooling T1 Heating H1 Indoor Outdoor Outdoor Indoor dB (A) dB(A) l/s Pa kW kW 5.0 (2.2-5.6) 5.4 (0.6-6.3) 4.3 1.56 1.70 3.21 3.18 P-Hi:37 Hi:32 Me:29 Lo:26 50 63 P-Hi: 217 Hi: 167 Me: 150 Lo: 133 100@217 l/s 280 x 750 x 635 640 x 800 (+71) x 290 29 45 6.35 12.7 5.6 (2.8-6.3) 6.7 (0.6-7.1) 4.9 1.75 2.00 3.20 3.35 P-Hi:36 Hi:31 Me:28 Lo:25 54 64 P-Hi:333 Hi:250 Me:217 Lo:167 100@333 l/s 280 x 950 x 635 640 x 800 (+71) x 290 34 45 6.35 12.7 FDUM50VF SRC50ZJX-S FDUM60ZJXVF FDUM60VF SRC60ZJX-S FDUM71VNXVF FDUM71VF FDC71VNX 7.1 (3.2-8.0) 8.0 (3.6-9.0) 7.0 2.20 2.20 3.23 3.64 P-Hi:38 Hi:33 Me:29 Lo:25 51 66 P-Hi: 400 Hi: 316 Me: 250 Lo: 166 100@400 l/s 280 x 950 x 635 750 x 880 (+88) x 340 34 60 9.52 15.88 Flare Connection 3.8 30 50 170 x 1200 235 x 1280 4.5 30 100 170 x 1200 235 x 1280 4.5 30 100 170 x 1200 235 x 1280 FDUM100VNVF FDUM100VF FDC100VN 10.0 (4.0-11.2) 11.2 (4.0-12.5) 11.4 2.92 3.20 3.42 3.50 P-Hi:44 Hi:38 Me:36 Lo:30 49 70 P-Hi:600 Hi:467 Me:417 Lo:317 100@600 l/s 280 x 1370 x 740 845 x 970 x 370 54 81 9.52 15.88 FDUM125VNXVF FDUM125VF FDC125VNX 12.5 (5.0-14.0) 14.0 (4.0-17.0) 13.7 3.60 3.90 3.47 3.59 P-Hi:45 Hi:40 Me:34 Lo:29 50 70 P-Hi:650 Hi:533 Me:433 Lo:333 100@650 l/s 280 x 1370 x 740 1300 x 970 x 370 54 105 9.52 15.88 FDUM140VNXVF

PRODUCTS

FDUM140VF FDC140VNX 14.0 (5.0-14.5) 16.0 (4.0-18.0) 14.3 4.48 4.54 3.15 3.63 P-Hi:47 Hi:40 Me:35 Lo:30 49 72 P-Hi:800 Hi:583 Me:467 Lo:367 100@800 l/s 280 x 1370 x 740 1300 x 970 x 370 54 105 9.52 15.88

1 Phase 230V 50Hz

kg mm

RC-E5, RC-EX1A or RCN-KIT3-E

FDUM71VF
Model FDUM71VF

Models FDUM100VF, 125VF, 140VF

FDUM100VF, 125VF, 140VF


Symbol Content Gas piping Liquid piping Drain piping Drain piping Gravity drainage 15.88 5 8" Flare 9.52 3 8" Flare VP20 standard:I.D.20, O.D.26 or VP25 Used with attached socket:I.D.25, O.D.34 Note 2 VP20 standard:I.D.20, O.D.26 or VP25 Used with attached socket:I.D.25, O.D.34

Duct dimension

23.5

200

41

31

200

Drain hose piece Accessory Installed on site

D E F G

170

205

C2

235

C1

24.5

65 46

860 Duct dimension 4 200=800

65 46

Symbol A Gas piping B Liquid piping

Content 15.88 5 8"

Duct dimension

Flare

21.5

39

31

14 4 Holes for tapping screw

Return air duct

9.52 3 8" Flare VP20 standard:I.D.20, O.D.26 or VP25 Used Drain piping with attached socket:I.D.25, O.D.34 Note 2 Drain piping VP20 standard:I.D.20, O.D.26 or VP25 Gravity drainage Used with attached socket:I.D.25, O.D.34 Hole for wiring M10 Suspension bolts Outside air opening 150 Knock out for ducting

64 100 280

1280 Duct dimension 4 280=1120

64 100
Drain hose piece Accessory Installed on site

A B C1

C2 D E F

986
Hanger plate for suspension bolt

Suspension bolts pitch

18

950

18 284 81
Control box

Air outlet opening 125 Knock out for ducting H 450X450 Inspection hole Notes 1 The model name label is attached on the lid of the control box. 2 Prepare the connecting socket VP20 or VP25 on site. 4 4 Holes for tapping screws 4 4 Holes for tapping screws

14 4 Holes for tapping screw

Return air duct

1404
Hanger plate for suspension bolt

Suspension bolts pitch

18

1368

28

152

262

139

472

Suspension bolts pitch

69

170
Hole

Max. drain lift

Max. drain lift

58 67
Duct dimension

B A

F
30

G View M

135

180

90

170

71

C1

170
Hole

E
Air supply duct

Duct dimension

295 325

280 250

600

170

55

880 Duct dimension

55

C2

467

104

1200 Duct dimension

104

C2

92

600 or less 280 250 184.5 134.5

105

635 510 471 413

30

59 69

G View M

90

170

30

E
Air supply duct

295 325

43

43

15

or less

170

50

76

175

45

15

738 635 468 405

467

113 30

C1

530

113

139

Suspension bolts pitch

124

28

18 284 81

F B A

Hole for wiring Suspension bolts M10 Outside air opening 150 Knock out for ducting Air outlet opening G 125 Knock out for ducting 450X450 H Inspection hole Notes 1 The model name label is attached on the lid of the control box. 4 4 2 Prepare the connecting socket VP20 or VP25 on site. 4 4 Holes for Holes for tapping screws 152 285 tapping screws Control box

24.5

124

11

12

FDT - Indoor Unit.


Ceiling Cassette-4way.

Remote control (Option)


Wired Wired

Remote control (Option) Remote

control (Option)
Wireless Wireless
FDT60 ~ 140VF

Wired

FDTC50VF

RC-EX1A

RC-EX1A RC-E5 RC-EX1A

RC-E5 RCH-E3 RCN-T-36W-E RCH-E3 RCH-E3 RC-E5 RCN-T-36W-E RCN-TC-24W-ER

Wireless

Outline drawing (Unit:mm)


Model FDT 60,71VF
G H

Model 100,125,140VF

B A

F H

B A

F H

FD series Inverter Packaged Air Conditioners 2013

Installation
Detachable covers at each corner allows for easy alignment and balance. The panel does not need to be removed. Installation time is reduced.

Infrared control option


For wireless control simply insert the infrared receiver kit on the corner.

PRODUCTS

wireless remote control wireless remote control RCN-T-36W-E RCN-T-36W-E wireless remote remote control control wireless RCN-T-36W-E RCN-T-36W-E

Easy checking of drain pan


To check the drain pan simply remove the corner lid.

700mm Drain Pump


Drain can be discharged upwards by Flexible 700mm from Flexible hose the hose ceiling surface. The 260mm flexible hose is supplied as standard equipment.
than than Flexiblehose hoselessless Flexible 700mm 700mm lessthan than less 700mm 700mm

FDT
FDT60ZJXVF Indoor Outdoor Power supply Indoor Unit Cooling T1 Capacity Heating H1 Heating H2 Input EER COP Sound pressure level (JIS C9612) Sound power level (JIS C9612) Air ow Panel External dimensions (HXWXD) Net weight Indoor Outdoor Indoor Outdoor Liquid line Refrigerant piping Gas line Connection method Refrigerant R410A Maxium Pipe Length Controller Quantity Pre charged to pipe length kg m m 1.5 15 30 50 RC-E5, RC-EX1A or RCN-T-36W-E 2.95 Cooling T1 Heating H1 Cooling T1 Heating H1 Indoor Outdoor Outdoor Indoor dB(A) l/s mm mm 246 x 840 x 840 640 x 800(+71) x 290 750 x 880(+88) x 340 845 x 970 x 370 dB (A) kW kW 5.6 (2.8-6.3) 6.7 (3.1-7.1) 5.29 1.52 1.70 3.68 3.94 P-Hi:46 Hi:33 Me:31 Lo:30 54 64 P-Hi: 466 Hi: 300 Me: 266 Lo: 233 7.1 (3.2-8.0) 8.0 (3.6-9.0) 7.2 2.04 1.94 3.48 4.12 P-Hi:46 Hi:35 Me:33 Lo:31 51 66 P-Hi: 466 Hi: 350 Me: 316 Lo: 283 FDT60VF SRC60ZJX-S FDT71VNXVF FDT71VF FDC71VNX FDT100VNVF FDT100VF FDC100VN 1 Phase 230V 50Hz 10.0 (4.0-11.2) 11.2 (4.0-12.5) N/A 2.76 2.74 3.62 4.09 P-Hi:51 Hi:40 Me:37 Lo:35 49 70 P-Hi: 616 Hi: 450 Me: 400 Lo: 333 T-PSA-3BW-E (35 x 950 x 950) 298 x 840 x 840 1300 x 970 x 370 Unit 27 Panel 5.5 60 81 9.52 15.88 Flare connection 3.8 30 100 4.5 105 12.5 (5.0-14.0) 14.0 (4.0-17.0) 15.6 3.28 3.43 3.81 4.08 P-Hi:51 Hi:42 Me:40 Lo:37 50 70 P-Hi: 616 Hi: 500 Me: 450 Lo: 383 14.0 (5.0-16.0) 16.0 (4.0-18.0) 16 4.19 4.2 3.34 3.81 P-Hi:51 Hi:43 Me:41 Lo:38 52 72 P-Hi: 616 Hi: 500 Me: 450 Lo: 383 FDT125VNXVF FDT125VF FDC125VNX FDT140VNXVF FDT140VF FDC140VNX

kg

Unit 24 Panel 5.5 45 6.35 12.7

mm

13

14

FDTC - Indoor Unit.


Ceiling Cassette-4way Compact 600x600mm

Remote control (Option) Remote control (Option) Wireless Wired Wireless Wired Wired Wireless

Remote control (Option)

FDTC50VF

FDTC50VF FDTC50VF

RC-EX1A RC-EX1A

RC-EX1A RC-E5 RC-E5

RC-E5 RCH-E3 RCN-TC-24W-ER RCH-E3 RCN-TC-24W-ER RCH-E3 RCN-TC-24W-ER

Outline drawing (Unit:mm)

A B

C F

FD series Inverter Packaged Air Conditioners 2013

Taking OA (Outside air intake) into inside


OA Spacer TC-OAS-E (option) Joint Duct TC-OAD-E (option) Utilizing OA spacer which Indoor Unit FDTC comes as optional equipment, Indoor Unit FDTC outside air can be taken Indoor Unit FDTC into inside. Indoor Unit FDTC Using 1 joint duct: Indoor Unit FDTC OA 3 300mm OA comes up to 1.3m /min. OA Spacer 300mm Spacer OA Using 2 joint ducts: Spacer Ceiling OA 300mm OA 2.6m3/min. OA OA comes from 1.3 to Ceiling surface OA OA Spacer
surface surface
(dB)

Quiet operation
(dB) Sound Pressure level in the Lo mode
(dB)

36 34 33 32

36 35
36 35 36 34 35 33 34 32 33 31 32 300mm 30 31 29 30 28 29

35 35dB

35dB

(dB)

35dB 35dB

34 33
3632 3531 3430 3329
(dB)

35dB31
30

Ceiling OA surface OA Ceiling OA

Spacer Panel Panel

OA Panel OA

Panel

Joint Duct

27 28 26 300mm 27 Joint Duct Joint Duct 25 26 25

28 5dB 3127 Down 5dB 30 26 Down 29


28

32

30dB29 30dB28
27 26

3dB Down 3dB 32dB Down 3dB 30dB 32dB 30dB Down 32dB 5dB 32dB 5dB

3dB Down

3dB Down

32dB

PRODUCTS

Down

Down

30dB
New New (Cooling) (Heating) New (Heating)

25

25 5dB

CLEARERAir Flow

surface

Joint Duct Ceiling OA Panel

OA
Joint Duct

Previous 26 (Cooling/Heating) Previous 25 (Cooling/Heating)

27

Compact and Convenient


New (Cooling) New (Heating)

(Cooling) New (Cooling) Previous (Cooling/Heating)

Previous New Previous New New (Cooling/Heating) (Cooling/Heating) (Cooling)


(Heating) New (Heating)

Down

New shape & angled louver redirects the air current away from the ceiling, to reduce ceiling stains

Installation Workability
For wireless control simply insert the infrared receiver kit on a corner of the panel wireless
remote wirelesscontrol 248mm RCN-TC-24W-ER remote control wireless wireless wireless remote control RCN-TC-24W-ER remote remote control control
248mm

600mm Drain Pump Drain can be discharged upward by 600 mm from the ceiling surface close to the indoor unit. It allows a piping layout with a high degree of freedom depending on the installation location. 600 x 600 ceiling Indoor unit size (W:570 x D:570) brings easy installation for 600 x 600 ceiling and Panel size (700 x 700) is suitable for 600 x 600 ceiling. Height is one of the industrys lowest level at 248mm and Flexible hose weight is only 16.5kg.
Flexible hose 600mm Flexible hose Flexible hose 600mm Flexible hose 600mm

600mm

248mm

248mm

600mm

248mm

RCN-TC-24W-ER

RCN-TC-24W-ER RCN-TC-24W-ER

FDTC
FDTC50ZJXVF Indoor Outdoor Power supply Outdoor Unit Cooling T1 Capacity Heating H1 Heating H2 Input EER COP Sound pressure level (JIS C9612) Sound power level (JIS C9612) Air ow Panel External dimensions (HXWXD) Cooling T1 Heating H1 Cooling T1 Heating H1 Indoor Outdoor Outdoor Indoor TC-PSA-25W-E Indoor Outdoor Indoor Outdoor Liquid line Refrigerant piping Gas line Connection method Refrigerant R410A Maxium Pipe Length Controller
VF model may be supplied in lieu.

FDTC50VF SRC50ZJX-S 1 Phase 230V 50Hz 5.0(1.1-5.6) kW 5.4 (0.6-6.3) 5.10 kW 1.56 1.45 3.20 3.72 dB (A) dB(A) l/s mm mm P-Hi:47 Hi:42 Me:36 Lo:32 54 63 P-Hi: 225 Hi: 191 Me: 150 Lo: 133 35 x 700 x 700 248 x 570 x 570 640 x 800(+71) x 290 Unit 15 Panel 3.5 45 6.35 12.7 Flare connection kg m m 1.5 15 30 RC-E5, RC-EX1A or RCN-TC-24W-ER

Net weight

kg

mm

Quantity Pre charged to pipe length

15

16

FDEN - Indoor Unit.


Ceiling Suspended.

FDEN100/125VF

FDEN 100/125VF
Remote control (Option) Remote control (Option) Remote control (Option)

Wired Wired

Wired

Wireless Wireless Wireless

FDTC50VF

FDTC50VF

RCH-E3 RC-EX1A RC-E5 RC-E5 RC-EX1A RC-EX1A RC-E5

RCN-TC-24W-ER RCH-E3 RCN-E1R RCH-E3 RCN-TC-24W-ER

Remote control (Option)


Wired Wireless

Outline drawing (Unit:mm)


24 a (Suspension bolts pitch) 24 5

290(Suspension bolts pitch) 135

Holes for suspension bolts (M8 to M10x4pcs.Not included) 410 145 52 Liquid piping

Space for installation and service

173

Gas piping

100 or more

300 or more

RC-EX1A
e d 40 b c Air outlet 40

RC-E5
690

68

RCH-E3 RCN-E1R
150 or more 5 or more 53 109 Obstacles Drain hole connection(1) (VP20 (I.D.20))

195 235 271


Indication board

Note(1) The slope of drain piping inside the unit is able to take incline of 10mm. 10 53

Drain hole connection(1) (VP20(I.D.20)) 76

Air inlet grille

Gas piping Drain hole connection(1) (VP20(I.D.20))

75 Liquid piping 110 135

Dimension Table
model FDEN100~125 a 1572 b 1540 c 1620 d 255 e 250

FD series Inverter Packaged Air Conditioners 2013

308

Improved installation workability


Increased freedom of a piping layout

Compact and modern design


PRODUCTS

Up Up Right Right Rear


The refrigerant pipe from the unit can be arranged in three directions, rear, right and up. The drain pipe can be arranged in two directions, left and right. This will allow a free layout of piping for various installation conditions. The unit can only be serviced from below.

Height Height 250mm 250mm

All models fit compactly on ceiling. (Height-210mm or 250mm). Plain, modern design featuring rounded edges gives room a comfortable atmosphere.

FDEN
FDEN100VNVF Indoor Outdoor Power supply Outdoor Unit Cooling T1 Capacity Heating H1 Heating H2 Input EER COP Energy Label Cooling T1 Heating H1 Cooling T1 Heating H1 Cooling T1 Heating H1 Indoor Outdoor Outdoor Indoor Indoor Outdoor Indoor Outdoor Liquid line Refrigerant piping Gas line Connection method Refrigerant R410A Maxium Pipe Length Controller Quantity Pre charged to pipe length kg m m 50 RC-E5, RC-EX1A or RCN-E-E 3.8 30 100 Stars kW kW 10 (4.0-11.2) 11.2 (4.0-12.5) NA 2.85 2.97 3.51 3.77 2 2.5 P-Hi:46 Hi:44 Me:41 Lo:39 49 70 P-Hi:466 Hi:433 Me:383 Lo:350 250 x 1620 x 690 845 x 970 x 370 49 81 9.52 15.88 Flare Connection 4.5 105 1300 x 970 x 370 FDEN100VF FDC100VN 1 Phase 230V 50Hz 12.5 (5.0-14.0) 14.0 (4.0-17.0) 15.0 3.86 3.77 3.23 3.71 1 2 P-Hi:50 Hi:46 Me:44 Lo:43 50 70 P-Hi:533 Hi:483 Me:433 Lo:383 FDEN125VNXVF FDEN125VF FDC125VNX

Sound pressure level (JIS C9612) Sound power level (JIS C9612) Air ow External dimensions (HXWXD)

dB (A) dB(A) l/s mm

Net weight

kg

mm

17

18

Hyperinverter.
Outdoor Unit 5.0-14.0kW.

Micro

SRC50/60ZJX-S

FDC71VNX

FDC100VN

FDC125/140VNX

Blue Fin 7.1-14.0kW


Due to application of blue coated fins (KS101) for the heat exchanger of the new outdoor unit, corrosion resistance has been improved compared to previous models.

Base heater kit (option)


This kit is recommended for use in areas where the temperature drops below 0C.

Blue Fin

Blue Fin

CW-H-E applied for FDC100VN FDC125~140VNX

Installation workability.
Enhanced installation workability thanks to the extended pipe length one of the longest levels in the industry. Units are pre-charged with refrigerant.

Piping length 100m (Hyper Inverter 12.5~14.0kW)

Micro Inverter
Height difference
(Outdoor higher than Indoor)

Height difference
(Outdoor higher than Indoor)

Piping length
Piping length 30m 50m 100m Height difference 20m 30m 30m

Piping length

kW 5~6 7.1 12.5~14

kW 10

Piping length 50m

Height difference 30m

Refrigerant precharged piping length extending to 30m


Precharged refrigerant piping length extends up to 30m. (5.0 & 6.0kW up to 15m) This eliminates the need to add refrigerant on site, which sets it free from the trouble of excessive or insufficient charging of refrigerant, and allows smooth installation.

FD series Inverter Packaged Air Conditioners 2013

High ef ciency.
Reduction of air ow pressure loss
Pressure caused by air flow in the indoor unit is reduced by making the air outlet larger. The reduction of pressure reduces the load on the fan motor so efficiency increases.

Increase of heat transfer ef ciency


Heat transfer efficiency has improved by using high efficiency piping and by the redesign of the heat exchanger from 2 to 1 piece.

PRODUCTS

Convenience.
common

A dry contact is fitted to each indoor unit which is used when a signal output is required.

CnT

XR2 XR3 XR4 XR5

XR2 XR3 XR4

output2 (heat) output3 (comp on) output4 (alarm) in put

XR5 XR1~5 : approx. DC12v

Monitoring Function
Condensers are fitted with RS232C so you can connect directly to your PC for monitoring. MHIs service software (Mente PC) makes service simpler.

Remote control RC-E5


The new remote control for all indoor units. Non-polar 2 core wiring is used. Installation is easier.

Previous

Current

3-core

2-core

All models employ R410A with RoHS* directive.


Employment of lead free solder
Adapt to RoHS
Pressure caused by air flow in the indoor unit is reduced by making the air outlet larger. The reduction of pressure reduces the load on the fan motor so efficiency increases.
*RoHS is the abbreviation of the new European standard, which means Restriction of Hazardous Substances.

Employment of R410A refrigerant


All models of the FD inverter series use refrigerant R410A characterized by an ozone depletion coefficient of 0.

Power source

CnT terminal

XR1

XR1

output1 (run)

19

20

Control System.
KX6 series

SUPERLINKSC-SL1N-E

RAC series (SRK/SRF-ZJX-S)

SC-BIKN-E

SC-ADNA-E

SC-SL2NA-E

SC-ADNA-E

SC-ADNA-E

Central Control

SC-SL1N-E

SC-SL2NA-E

SC-SL3N-AE/BE

Start/stop control of up to 16 indoor units is possible either individually or collectively. With simple operations, you can effect centralised control.

Centralised control of up to 64 indoor units. Allows connection with a weekly timer without using any interface.

Easy operation through the large color LCD and touch panel. Up to 128 indoor units can be controlled, when three SUPERLINK-II systems are connected.

PC windows central control

BMS interface unit

SC-WGWNA-A/B
(SC-WGWNA-B has electric power calculation function)

SC-BGWN-A/B
(SC-WGWN-B has electric power calculation function)

(BACnet gateway)

(LonWorks gateway)

SC-LGWN-A

Up to 96 cells (some cells can have two or more indoor units and total number of indoor units can be up to 128 units) are controlled from the Internet.
Additional engineering service cost is required. Please consult your dealer when using this central control.

Up to 96 cells (some cells can have two or more indoor units and total number of indoor units can be up to 128 units) are controlled centrally from a BMS.
Additional engineering service cost is required. In case of SC-BGWN-B, communication test by quali ed person regarding electric cost calculation function is required before commissioning. Please consult your dealer when using this gateway.

Up to 96 indoor units (48 indoor unit x 2) are linked as an open network. Centrally controlled through LonWorks.
Additional engineering service cost is required. Please consult your dealer when using this gateway.

FD series Inverter Packaged Air Conditioners 2013

SUPERLINK E BOARD (SC-ADNA-E)


This board is used when conducting control of the single package (wired remote control unit) 1-type series using a network option (SC-SL1N-E, SC-SL2NA-E, etc).

coNtroL sYstEM

(1) Functions
(a) Transmits the settings from the network option to the indoor units. (b) Returns the priority indoor unit data in response to a data request from the network option. (c) Inspects the error status of connected indoor units and transmits the inspection codes to the network option. (d) A maximum of 16 units can be controlled (if in the same operation mode).

(2) Wiring connection diagram


Connected to the terminals for Superlink signal lines MVVS 0.75 - 1.25mm2

SL E board

A B X Y

Blue Blue Black White

A B X Y

ON OFF
SW3 SW1 SW2

Master/Sub address

Basic Connections
Outdoor unit Internal/external Crossing Indoor unit X Y SL E Board X Y A B Network A B options Remote control X Y

Plural Controls by Multiple Remote Controls. Mixture of Multiple Units


Outdoor unit Internal/external Crossing Inside Inside Inside Inside Outdoor unit Internal/external Crossing Inside Inside Inside

Run Abnormal
SL E Board Network options

(3) Metal box dimension


85 40 22.5 5 35 30

100

90

2-6

70

LED2

LED3
R SL E Board

Connected to the remote controller terminals (no polarity) (the length should be 600 m or shorter) 200 m or shorter 0.5 mm2 x 2 cores 300 m or shorter 0.75 mm2 x 2 cores 400 m or shorter 1.25 mm2 x 2 cores 600 m or shorter 2.0 mm2 x 2 cores

Network address setting switches [000]-(127)

Plural Controls by Multiple Remote Controls. Mixture of Multiple Units

Outdoor unit Internal/external Crossing Inside Inside Inside Inside

SL E Board Network options

Transmit the information of plural Master units to the network. Transmit the abnormalities of the Slave units to the network. Setting the plural Master/Slave units with the dip SW of the printed circuit board. Setting the Master/Slave remote controls with the dip SW of the remote control board.

Without Remote Control


Outdoor unit Internal/external Crossing Inside Inside

Wireless Kit
Outdoor unit Internal/external Crossing Inside Inside

SL E Board Network options

Set up 000 to 127 using address switch on the SL E board.

Set the SL E board dip SW to Master SW3-1 ON. The network option SLA-1-E, SL1N-E is not allowed (This will disturb switching of the operation mode)

SL E Board Network options

Wireless Kit

Wireless remote control

21

22

Control System.
Individual Control.
Remote Control line up
indoor unit wired all models remote control RC-E5 RCH-E3 wireless indoor unit FDT FDTC FDUM, FDU FDEN remote control RCN-T-36W-E RCN-TC-24W-ER RCN-KIT3-E RCN-E-E

Wired remote control with weekly timer (option)


RC-E5
Run hour metres to facilitate maintenance checking
RC-E5 stores operation data when an anomaly occurs and indicates the error on the LCD. It also displays cumulative operation hours of the air conditioner and compressor since commissioning.

The RC-E5 controller enables extensive access to service and maintenance technical data combined with easy to use functions and a clear LCD display.

Room temperature controlled by the remote control sensor


The temperature sensor is housed in the top section of the remote control unit. This arrangement has improved the sensitivity of the remote control units sensor, which permits more nely controlled air conditioning.

Weekly timer function as standard


RC-E5 provides (as a standard feature) a weekly timer, which allows one-week operation schedules to be registered. A user can specify up to four times a day to start/stop the air conditioner. (Temperature setting is also possible with the timer).

Changeable set temperature ranges


RC-E5 allows the upper and lower limits of a set temperature range to be speci ed separately. By adjusting a set temperature range, you can ensure energy saving air conditioning by avoiding excessive cooling or heating. Changeable range Upper limit Lower limit 20~30C(effective for heating operation) 18~26C(effective for non-heating operation)

Timer operation

Simple remote control (option)


RCH-E3 (wired)
Considering specialised usage in hotel rooms, control buttons are limited only to minimum required functions such as ON/OFF, mode, temperature setting and fan speed. It is really simple and easy to use.
RCH-E3 is not applicable to the Individual ap control system and the Flap control system. When RCH-E3 is used, the fan has 3 speed settings (Hi-Me-Lo) only.

Up to 16 units
It can control up to 16 units individually, by pressing the AIR CON No. button.

AUTO restart
This function allows starting the air conditioner automatically when power supply is restored after power failure or by turning on the power switch.

Wireless remote control (option)


For wireless control simply insert the infrared receiver kit on a corner of the panel.

Thermistor (option)
SC-THB-E3
This sensor is used when individual remote control is not required in each room and the system is under central control. By installing sensors in strategic locations through out the structure greater comfort control is achieved. In many instances one additional sensor is all that is required.

RCN-T-36W-E, RCN-TC-24W-ER

RCN-KIT3-E

RCN-E-E

When wireless remote control is used, the fan has 3 speed settings (Hi-Me-Lo) only.

FD series Inverter Packaged Air Conditioners 2013

KX-KXR.
Industry leading energy ef ciency and reliability from our advanced technology.
Mitsubishi Heavy Industries offers one of the largest ranges of VRF multi inverter products in the industry. The compact M series (11.2 to 15.5kW) is a single fan, single phase outdoor that is providing air conditioning solutions all over Australia and New Zealand. The larger side blow (22.4 to 33.5kW) and top discharge (40 to 68kW) units can be used singularly or in combination to deliver up to 136kW of heat pump or heat recovery technology and energy saving in high rise and mid rise structures. With 16 types of indoor units and 78 different capacities available designs are only limited by imagination. Our eSolution software makes selection simple. The SuperlinkII network can control up to 128 indoor units via a central control or BMS interface such as Web or BACnet gateways. Mente PC can be connected for fault finding and recording test run reports.
VRF inverter multi-system Air-Conditioners

PRODUCTS

SR.
Residential Air Conditioner.
Mitsubishi Heavy Industries wall mounted and floor standing inverter split systems are the ideal choice to control comfort in any residential situation. Mitsubishi Heavy Industries residential air conditioners have received rave reviews in consumer magazines here and overseas when tested and compared to the competitions similar products. Energy efficiency, quite operation and ease of use were the standout differences.

SCM.
Residential Air Conditioner.
These residential use inverter multi system can condition 2 to 6 rooms using either wall mounted, floor standing, low static bulkhead or compact cassette type indoor units. The SCM series offers a total of 7 outdoor units and many indoor units making hundreds of different comfort combinations possible. Perfect for homes and apartments.

23

Before starting use


Heating performance
The heating performance values (kW) described in catalog are the values obtained by operating at an outdoor temperature of 7C and indoor temperature of 20C as set forth in the ISO Standards. As the heating performance decreases as the outdoor temperature drops, if the outdoor temperature is too low and the heating performance is insuf cient, use other heating appliances as well.

Refrigerant leakage
The refrigerant (R410A) used for Air conditioner is non-toxic and non ammable in its original state. However, in consideration of a state where the refrigerant leaks into the room, measures against refrigerant leaks must be taken in small rooms where the tolerable level could be exceeded. Take measures by installing ventilation devices, etc.

Indication of sound values


The sound values are the values (A scale) measured in a chamber such as an anechoic chamber following the ISO Standards. In the actual installation state, the value is normally larger than the values given in the catalog due to the effect of surrounding noise and echo. Take this into consideration when installing.

Use in snowy areas


Take the following measures when installing the outdoor unit in snowy areas.

Snow prevention
Install a snow-prevention hood so that the snow does not obstruct the air intake port or enter and freeze in the outdoor unit.

Use in oil atmosphere


Avoid installing this unit in as atmosphere where oil scatters or builds up, such as in a kitchen or machine factory. If the oil adheres to the heat exchanger, the heat exchanging performance will drop, mist may be generated, and the synthetic resin parts may deform and break.

Snow piling
In areas with heavy snow fall, the piled snow could block the air intake port. In this case, a frame that is 50cm or higher than the estimated snow fall must be installed underneath the outdoor unit.

Use in acidic or alkaline atmosphere


If this unit is used in acidic atmosphere such as hot spring areas having high level of sulfuric gases or in alkaline atmosphere including ammonia or calcium chloride, places where the exhaust of the heat exchanger is sucked in, or at coastal areas where the unit is subject to salt breezes, the outer plate or heat exchanger, etc., will corrode. Please ask a dealer or specialist when you use an air conditioner in places differing from a general atmosphere.

Automatic defrosting device


If the temperature is low, and the humidity is high, frost will stick to the heat exchanger of the outdoor unit. If use is continued, the heating performance will drop. The Automatic defrosting device will function to remove this frost. After heating for approx, three to ten minutes, it will stop, and the frost will be removed. After defrosting, hot air will be blown again.

Use in places with high ceilings

Servicing the air-conditioner


After the air-conditioner is used for several seasons, dirt will build up in the air-conditioner causing the performance to drop. In addition to regular servicing, we recommend the maintenance contract (charged for) by a specialist.

If the ceiling is high, install a circulator to improve the heat and air ow distribution when heating.

Safety Precautions
Air-conditioner usage target
The air-conditioner described in this catalog is a dedicated cooling/heating device for human use. Do not use it for special applications such as the storage of foodstuffs, animals or plants, computer server rooms, precision devices or valuable art, etc. This could cause the quality of the items to drop, etc. Do not use this for cooling vehicles or ships. Water leakage or current leaks could occur.

Installation
Always commission the installation to a dealer or specialist. Improper installation will lead to water leakage, electric shocks and res. Make sure that the outdoor unit is stable in installation. Fix the unit to stable base.

Usage place
Do not install in places where combustible gas could leak or where there are sparks. Installation in a place where combustible gas could be generated, ow or accumulate, or places containing carbon bers could lead to res.

Before use
Always read the User,s Manual thoroughly before starting use.

Only persons that are quali ed and licensed are permitted to install and service products that contain refrigerants in Australia, go to www.arctick.org. Suitable access for service must be provided in compliance with industry standards and local regulations.

MHIAA is proudly sponsoring Monikas Doggie Rescue

Australia:
ABN 92 133 980 275

New Zealand:
G.S.T. 105-673-620

Phone: 1300 138 007


NSW & Head Office
9C Commercial Road Kingsgrove NSW 2208 PO Box 318 Kingsgrove NSW 1480

Fax: 1800 644 329


Victoria
2/24 Lakeside Drive Burwood East VIC 3151

Phone: 0800 138 007 Fax: 09 442 5346


Western Australia
Unit 3A 2 Mulgul Rd Malaga WA 6090 PO Box 2089 Malaga WA 6944

Queensland
5/26 Flinders Parade North Lakes QLD 4509

Auckland
Unit 2 100 Bush Road Albany 0632 PO Box 300552 Albany 0632

www.mhiaa.com.au

www.mhiaa.co.nz
www.mrespareparts.com.au Tel: +61 (0) 2 9600 7444 Fax: +61 (0) 2 9600 8044

MRE SPARE PARTS


ISO9001
Our Air Conditioning & Refrigeration Systems Headquarters is an ISO9001 approved factory for residential air conditioners and commercial-use air conditioners (including heat pumps).

ISO14001
Our Air Conditioning & Refrigeration Systems Headquarters has been assessed and found to comply with the requirements of ISO14001.
ISO 14001
Certi cate 04104 1998 0813 E5
Mitsubishi Heavy Industries, Ltd. Air-conditioning & Refrigeration Systems Headquarters Certi ed ISO 14001 Certi cate number : JQA-EM0256

Certi ed ISO 9001 Certi cate Number : 04100 1998 0813

Certi cate Number : 04104 1998 0813 E5

Because of our policy of continuous improvement, we reserve the right to make changes in all specifications without notice. E&OE.